UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Mr. Jason Remer Nuclear Energy Institute 1201 F. St, NW Suite 1100 Washington, DC 20004-1218
SUBJECT:
LICENSE RENEWAL INTERIM STAFF GUIDANCE, LR-ISG-2015-01, CHANGES TO BURIED AND UNDERGROUND PIPING AND TANK RECOMMENTATIONS
Dear Mr. Remer:
On June 29, 2015, the U.S. Nuclear Regulatory Commission (NRC) published in the Federal Register (80 FR 37028) a request for public comment on Draft License Renewal Interim Staff Guidance (LR-ISG), LR-ISG-2015-01, Changes to Buried and Underground Piping and Tank Recommendations. In response, the Nuclear Energy Institute (NEI) submitted comments by letter dated August 6, 2015. Detailed responses to the comments can be found in Appendix D of the final LR-ISG-2015-01, Changes to Buried and Underground Piping and Tank Recommendations.
In developing these new recommendations, the staff developed:
Extensive changes to aging management program (AMP) XI.M41, Buried and Underground Piping and Tanks. LR-ISG-2015-01 includes a summary of all major changes. The most significant changes are those resulting in reductions in the number of excavated direct visual inspections of buried pipe when the cathodic protection system is not meeting performance goals, additional acceptance criteria for cathodic protection system performance, and recommendations related to the use of electrical resistance corrosion rate probes.
Changes to the final safety analysis report (FSAR) supplement description for AMP XI.M41.
Changes to the detection of aging effects program element of AMP XI.M33, Selective Leaching.
Enclosed is a copy of the final LR-ISG-2015-01 and the Federal Register notice announcing the issuance of LR-ISG-2015-01.
To inform other stakeholders of the issuance of LR-ISG-2015-01, courtesy copies of this letter are being sent to subscribers of an NRC electronic mailing list on general license renewal topics.
January 28, 2016
If you have any questions, please contact William Holston of my staff by telephone at 301-415-8573 or by e-mail at William.Holston@nrc.gov, or Brian Allik of my staff by telephone at 301-415-1082 or by e-mail at Brian.Allik@nrc.gov.
Sincerely,
/RA/
Jane E. Marshall, Deputy Director Division of License Renewal Office of Nuclear Reactor Regulation
Enclosures:
- 1. Final LR-ISG-2015-01
- 2. Federal Register notice cc: Reactor License Renewal Stakeholder GovDelivery
ML15308A021 (Package)
ML15334A438 (Letter)
ML15308A018 (LR-ISG)
- concurrence via email OFFICE ME:DLR:RARB ME:DLR:RARB* LA:DLR:RPB1* PM:DLR:RSRG*
NAME WHolston BAllik YEdmonds SBloom DATE 11/2/15 11/16/15 1/13/16 11/3/15 OFFICE BC:DLR:RARB* STA:NRR/DE*
STA:NRR/DLR* OGC*
NAME DMorey RHardies AHiser STurk DATE 11/3/15 11/3/15 11/30/15 1/4/16 OFFICE D:DLR NAME JMarshall DATE 1/28/16
Letter to J. Remer from J. Marshall dated January 28, 2016
SUBJECT:
LICENSE RENEWAL INTERIM STAFF GUIDANCE, LR-ISG-2015-01, CHANGES TO BURIED AND UNDERGROUND PIPING AND TANK RECOMMENTATIONS DISTRIBUTION:
E-MAIL:
PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRarb Resource RidsNrrDlrRasb Resource RidsNrrDlrRerb Resource RidsNrrDra Resource RidsNrrDe Resource RidsNrrDss Resource RidsOgcMailCenter Resource RidsOpaMail Resource RidsOcaMailCenter Resource WHolston, NRR MGray, RI SVias, RII AStone, RIII