Official Exhibit - ENT000664-00-BD01 - Email from J. Holonich, NRC, to K. Amberge, EPRI, Et Al., Summary Tables for CASS Position (Mar. 12, 2014, 1:23 PM)
ML15334A268
Person / Time
Site: Indian Point  
Issue date: 03/12/2014
From:
Entergy Nuclear Operations
To:
Atomic Safety and Licensing Board Panel
SECY RAS
References
RAS 28136, ASLBP 07-858-03-LR-BD01, 50-247-LR, 50-286-LR
Download: ML15334A268 (2)


Text

From:

Holonich, Joseph Sent:

Wednesday, March 12, 2014 1:23 PM To:

Amberge, Kyle; 'Contractor - Wirtz, Charles' Cc:

Hardies, Robert; Hiser, Allen; Cheruvenki, Ganesh; Poehler, Jeffrey; Tregoning, Robert; Purtscher, Patrick; 'Andrew.Odell@exeloncorp.com' (Andrew.Odell@exeloncorp.com); Dyle, Robin; Rao, Appajosula

Subject:

Summary Tables For CASS Posittion.docx Attachments:

Summary tables for CASS posittion.docx Kyle/Chuck, As discussed today during our conference call, attached please find the subject tables. They are being provided to you for your use. The NRC staff would welcome any comments you may have.

A copy of this Email and the attachment will be placed in ADAMS and made publically available.

Joe Holonich ENT000664 Submitted: August 10, 2015 United States Nuclear Regulatory Commission Official Hearing Exhibit In the Matter of:

Entergy Nuclear Operations, Inc.

(Indian Point Nuclear Generating Units 2 and 3)

ASLBP #: 07-858-03-LR-BD01 Docket #: 05000247 l 05000286 Exhibit #:

Identified:

Admitted:

Withdrawn:

Rejected:

Stricken:

Other:

ENT000664-00-BD01 11/5/2015 11/5/2015

Proposed NRC position on Screening of CASS Reactor Vessel Internal Components The NRC staff requires licensees/applicants to consider embrittlement from both thermal aging and neutron irradiation. The staff would consider screening for susceptibility to embrittlement based on fluence and ferrite content (measured or calculated from Hulls equation and summarized in Tables A, B, and C shown below) to be conservative.

Table A Screening for Components with < 0.45 dpa neutron exposure Molybdenum (wt. %)

Casting Method Susceptibility Delta ferrite %

High 2.0-3.0%

(CF-8M) static TE

> 14%

No 14%

centrifugal TE

> 20%

No 20%

Low 0.5% max (CF-3 and CF-8) static TE

> 20%

No 20%

centrifugal No All Table B Screening for Components with 0.45 dpa neutron exposure 1.5 dpa Molybdenum (wt. %)

Casting Method Susceptibility Delta ferrite %

High 2.0-3.0%

(CF-8M) static TE + IE

> 10%

No 10%

centrifugal TE + IE

> 15%

No 15%

Low 0.5% max (CF-3 and CF-8) static TE + IE

> 15%

No 15%

centrifugal No All Table C Screening for Components with > 1.5 dpa neutron exposure Molybdenum (wt. %)

Casting Method Susceptibility Delta ferrite %

High 2.0-3.0%

(CF-8M) static TE + IE

> 10%

IE 10%

centrifugal TE + IE

> 15%

IE 15%

Low 0.5% max (CF-3 and CF-8) static TE + IE

> 15%

IE 15%

centrifugal IE All

From:

Holonich, Joseph Sent:

Wednesday, March 12, 2014 1:23 PM To:

Amberge, Kyle; 'Contractor - Wirtz, Charles' Cc:

Hardies, Robert; Hiser, Allen; Cheruvenki, Ganesh; Poehler, Jeffrey; Tregoning, Robert; Purtscher, Patrick; 'Andrew.Odell@exeloncorp.com' (Andrew.Odell@exeloncorp.com); Dyle, Robin; Rao, Appajosula

Subject:

Summary Tables For CASS Posittion.docx Attachments:

Summary tables for CASS posittion.docx Kyle/Chuck, As discussed today during our conference call, attached please find the subject tables. They are being provided to you for your use. The NRC staff would welcome any comments you may have.

A copy of this Email and the attachment will be placed in ADAMS and made publically available.

Joe Holonich ENT000664 Submitted: August 10, 2015 United States Nuclear Regulatory Commission Official Hearing Exhibit In the Matter of:

Entergy Nuclear Operations, Inc.

(Indian Point Nuclear Generating Units 2 and 3)

ASLBP #: 07-858-03-LR-BD01 Docket #: 05000247 l 05000286 Exhibit #:

Identified:

Admitted:

Withdrawn:

Rejected:

Stricken:

Other:

ENT000664-00-BD01 11/5/2015 11/5/2015

Proposed NRC position on Screening of CASS Reactor Vessel Internal Components The NRC staff requires licensees/applicants to consider embrittlement from both thermal aging and neutron irradiation. The staff would consider screening for susceptibility to embrittlement based on fluence and ferrite content (measured or calculated from Hulls equation and summarized in Tables A, B, and C shown below) to be conservative.

Table A Screening for Components with < 0.45 dpa neutron exposure Molybdenum (wt. %)

Casting Method Susceptibility Delta ferrite %

High 2.0-3.0%

(CF-8M) static TE

> 14%

No 14%

centrifugal TE

> 20%

No 20%

Low 0.5% max (CF-3 and CF-8) static TE

> 20%

No 20%

centrifugal No All Table B Screening for Components with 0.45 dpa neutron exposure 1.5 dpa Molybdenum (wt. %)

Casting Method Susceptibility Delta ferrite %

High 2.0-3.0%

(CF-8M) static TE + IE

> 10%

No 10%

centrifugal TE + IE

> 15%

No 15%

Low 0.5% max (CF-3 and CF-8) static TE + IE

> 15%

No 15%

centrifugal No All Table C Screening for Components with > 1.5 dpa neutron exposure Molybdenum (wt. %)

Casting Method Susceptibility Delta ferrite %

High 2.0-3.0%

(CF-8M) static TE + IE

> 10%

IE 10%

centrifugal TE + IE

> 15%

IE 15%

Low 0.5% max (CF-3 and CF-8) static TE + IE

> 15%

IE 15%

centrifugal IE All