1 IPRenewal NPEmails From:
Wentzel, Michael Sent:
Wednesday, September 30, 2015 9:24 AM To:
Louie, Richard
Subject:
RE: 2015 Service Water Leaks Thanks, Rich. I am on travel this week. It would be easiest for me to give you a call on Monday. Will that work?
From: Louie, Richard [1]
Sent: Tuesday, September 29, 2015 9:45 AM To: Wentzel, Michael
Subject:
[External_Sender] 2015 Service Water Leaks
- Mike, In our letter dated 8/18/2015, we provided information regarding the number of leaks on the SW system for the past 10-years. For year 2015, the number we provided was current as of 6/30/2015.
Since that time, there has been an increase in the number of reported through-wall leakage flaws in ASME ISI Class 3 SW piping. The new number is 6 as of 9/17/2015.
This condition is being tracked in our condition reporting system under CR-IP2-2015-04239.
Please call me at your convenience to discuss this.
- Thanks, Richard Louie rlouie@entergy.com Regulatory Assurance Indian Point Energy Center (914) 254-6618
Hearing Identifier:
IndianPointUnits2and3NonPublic_EX Email Number:
5312 Mail Envelope Properties (48cbb82065c646e4ad969ac7b1a65403)
Subject:
RE: 2015 Service Water Leaks Sent Date:
9/30/2015 9:23:32 AM Received Date:
9/30/2015 9:23:32 AM From:
Wentzel, Michael Created By:
Michael.Wentzel@nrc.gov Recipients:
"Louie, Richard" <rlouie@entergy.com>
Tracking Status: None Post Office:
HQPWMSMRS03.nrc.gov Files Size Date & Time MESSAGE 1020 9/30/2015 9:23:32 AM Options Priority:
Standard Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received: