Quad Cities, Units 1 & 2 Table 1. Current Design Basis Flood Hazards for Use in the MSA Mechanism Stillwater Elevation Waves/

Runup Reference Design Basis Hazard Elevation Note: Reported values are rounded to the nearest one-tenth of a foot.

Local Intense Precipitation Not included in DB Not included in DB Not included in DB FHRR Enclosure 1 Section 2.c Failure of Dams and Onsite Water Control/Storage Structures Not included in DB Not included in DB Not included in DB FHRR Enclosure 2 Table 1 Streams and Rivers 603.0 ft MSL1912 Not applicable 603.0 ft MSL1912 FHRR Enclosure 2 Table 1 Storm Surge No Impact on the Site Identified No Impact on the Site Identified No Impact on the Site Identified FHRR Enclosure 2 Table 1 Seiche No Impact on the Site Identified No Impact on the Site Identified No Impact on the Site Identified FHRR Enclosure 2 Table 1 Tsunami No Impact on the Site Identified No Impact on the Site Identified No Impact on the Site Identified FHRR Enclosure 2 Table 1 Ice-Induced Flooding Not included in DB Not included in DB Not included in DB FHRR Enclosure 2 Table 1 Channel Migrations/Diversions No Impact on the SIte Identified No Impact on the Site Identified No Impact on the Site Identified FHRR Enclosure 2 Table 1

Quad Cities, Units 1 & 2 Table 2. Reevaluated Flood Hazards for Flood-Causing Mechanisms for Use in the MSA Mechanism Stillwater Elevation Waves/

Runup Reevaluated Hazard Elevation Reference Note 2: Reevaluated hazard mechanisms bounded by the current design basis (see Table 1) are not included in this table.

Note 3: Reported values are rounded to the nearest one-tenth of a foot.

Local Intense Precipitation 596.5 ft MSL1912 Minimal 596.5 ft MSL1912 Table 4-2 in Enclosure 2 of the January 13, 2015 Response to Request for Additional Information (ML15021A179)

Min-doors by Safety Related Structures, Systems and Components 598.4 ft MSL1912 Minimal 598.4 ft MSL1912 Table 4-2 in Enclosure 2 of the January 13, 2015 Response to Request for Additional Information (ML15021A179)

Max-doors by Safety Related Structures, Systems and Components Failure of Dams and Onsite Water Control/Storage Structures 600.9 ft MSL1912 4.1 ft 605.0 ft MSL1912 FHRR Enclosure 2, Table 1 July 3, 2014 Response to Request for Additional Information (See RAI Item

  1. 2) ML14238A384 Combined Event: Riverine, Dam Failure and Waves Note 1: The licensee is expected to develop flood event duration parameters and applicable flood associated effects to conduct the MSA. The staff will evaluate the flood event duration parameters (including warning time and period of inundation) and flood associated effects during its review of the MSA.