Examination Report No. 50-186/OL-15-01, University of Missouri-Columbia
ML15236A130
Person / Time
Site: University of Missouri-Columbia
Issue date: 08/31/2015
From: Kevin Hsueh
Research and Test Reactors Branch B
To: Rhonda Butler
Univ of Missouri - Columbia
Phillip Young - 301-415-4094
Shared Package
ML15169A041 List:
References
50-186/OL-15-01
Download: ML15236A130 (2)


Text

August 31, 2015 Mr. Ralph A. Butler, Executive Director University of Missouri - Columbia Research Reactor Center 1513 Research Park Drive Columbia, MO 65211

SUBJECT:

EXAMINATION REPORT NO. 50-186/OL-15-01, UNIVERSITY OF MISSOURI -

COLUMBIA

Dear Mr. Butler:

During the week of July 20, 2015, the U. S. Nuclear Regulatory Commission administered operator licensing examinations at your University Of Missouri - Columbia Reactor. The examinations were conducted according to NUREG-1478, "Operator Licensing Examiner Standards for Research and Test Reactors," Revision 2. Examination questions and preliminary findings were discussed with those members of your staff identified in the enclosed report at the conclusion of the examination.

In accordance with Title 10 of the Code of Federal Regulations Section 2.390, a copy of this letter and the enclosures will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. The NRC is forwarding the individual grades to you in a separate letter which will not be released publicly. Should you have any questions concerning this examination, please contact Mr. Phillip T. Young at (301) 415-4094 or via email Phillip.Young@nrc.gov.

Sincerely,

/RA/

Kevin Hsueh, Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-186

Enclosure:

1. Examination Report No. 50-186/OL-15-01 cc w/enclosure: Mr. John Fruits, Reactor Manager cc w/o enclosures: See next page

Mr. Ralph A. Butler, Executive Director August 31, 2015 University of Missouri - Columbia Research Reactor Center 1513 Research Park Drive Columbia, MO 65211

SUBJECT:

EXAMINATION REPORT NO. 50-186/OL-15-01, UNIVERSITY OF MISSOURI -

COLUMBIA

Dear Mr. Butler:

During the week of July 20, 2015, the U. S. Nuclear Regulatory Commission administered operator licensing examinations at your University Of Missouri - Columbia Reactor. The examinations were conducted according to NUREG-1478, "Operator Licensing Examiner Standards for Research and Test Reactors," Revision 2. Examination questions and preliminary findings were discussed with those members of your staff identified in the enclosed report at the conclusion of the examination.

In accordance with Title 10 of the Code of Federal Regulations Section 2.390, a copy of this letter and the enclosures will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. The NRC is forwarding the individual grades to you in a separate letter which will not be released publicly. Should you have any questions concerning this examination, please contact Mr. Phillip T. Young at (301) 415-4094 or via email Phillip.Young@nrc.gov.

Sincerely,

/RA/

Kevin Hsueh, Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-186

Enclosure:

1. Examination Report No. 50-186/OL-15-01 cc w/enclosure: Mr. John Fruits, Reactor Manager cc w/o enclosures: See next page DISTRIBUTION w/ enclosures PUBLIC PRTB r/f RidsNRRDPRPRTA RidsNRRDPRPRTB ADAMS ACCESSION #: ML15236A130 TEMPLATE #:NRR-074 OFFICE PROB:CE IOLB:LA PROB:BC NAME PYoung CRevelle KHsueh DATE 7/28/2015 8/24/2015 8/31/2015 OFFICIAL RECORD COPY

University Of Missouri - Columbia Docket No. 50-186 cc:

Les Foyto, Associate Director University of Missouri-Columbia Research Reactor Center 1513 Research Park Drive Columbia, MO 65211 Homeland Security Coordinator Missouri Office of Homeland Security P.O. Box 749 Jefferson City, MO 65102 Planner, Dept. of Health and Senior Services Section for Environmental Public Health P.O. Box 570 Jefferson City, MO 65102-0570 Deputy Director for Policy Department of Natural Resources 1101 Riverside Drive Fourth Floor East Jefferson City, MO 65101 A-95 Coordinator Division of Planning Office of Administration P.O. Box 809, State Capitol Building Jefferson City, MO 65101 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611

U. S. NUCLEAR REGULATORY COMMISSION OPERATOR LICENSING INITIAL EXAMINATION REPORT REPORT NO.:

50-186/OL-15-01 FACILITY DOCKET NO.:

50-186 FACILITY LICENSE NO.:

R-103 FACILITY:

University of Missouri - Columbia EXAMINATION DATES:

July 21 & 22, 2015 SUBMITTED BY:

Phillip T. Young, Chief Examiner Date

SUMMARY

During the week of July 20, 2015 the U. S. Nuclear Regulatory Commission administered examinations to two SRO Upgrade applicants. Both applicants passed the examinations.

REPORT DETAILS

1.

Examiners:

Phillip T. Young, Chief Examiner, NRC

2.

Results:

RO PASS/FAIL SRO PASS/FAIL TOTAL PASS/FAIL Written 0/0 0/0 0/0 Operating Tests 0/0 2/0 2/0 Overall 0/0 2/0 2/0

3.

Exit Meeting:

Phillip T. Young, Chief Examiner, NRC Carl Herbold, Assistant Reactor Manager of Operations, MURR John L. Fruits, Reactor Manager, MURR Les Foyto, Associate Director Reactor & Facilities Operations, MURR Rob Hudson, Reactor Operations Training Coordinator, MURR The examiner thanked the facility for their assistance in completing the examinations.

ENCLOSURE 1