1 NRR-PMDAPEm Resource From:

Higgins,Frank:(GenCo-Nuc) [frank.higgins@exeloncorp.com]

Sent:

Thursday, June 18, 2015 10:31 AM To:

DiFrancesco, Nicholas; Wyman, Stephen Cc:

Clark, Jeffrey S.:(GenCo-Nuc); Merritt, Chuck:(GenCo-Nuc); Waiters,Sheldon:(GenCo-Nuc)

Subject:

NRC ESEP questions - Calvert Cliffs Attachment 1A - Email 2 Attachments: A ESEP Unit 2 Containment Walkdown.pdf On behalf of Jeff Clark I am forwarding the Calvert Attachments.

Due to size limitations I split the PDF into two pdfs -one per unit. I will be sending attachments in separate emails. contains Executive summary and Unit 1 Containment walkdown photos. Email 1 A contains Unit 2 Containment walkdown photos Email 2 Please confirm receipt of these pdfs as it completes our response to the ESEP questions.

Thank You Frank Higgins Fukushima Seismic and Flooding Lead Calvert Cliffs Frank.higgins@exeloncorp.com 5743602413 C 4104952372 W This Email message and any attachment may contain information that is proprietary, legally privileged, confidential and/or subject to copyright belonging to Exelon Corporation or its affiliates ("Exelon"). This Email is intended solely for the use of the person(s) to which it is addressed. If you are not an intended recipient, or the employee or agent responsible for delivery of this Email to the intended recipient(s), you are hereby notified that any dissemination, distribution or copying of this Email is strictly prohibited. If you have received this message in error, please immediately notify the sender and permanently delete this Email and any copies.

Exelon policies expressly prohibit employees from making defamatory or offensive statements and infringing any copyright or any other legal right by Email communication. Exelon will not accept any liability in respect of such communications. -EXCIP

Hearing Identifier:

NRR_PMDA Email Number:

2275 Mail Envelope Properties (1EDF2730CFBC9D409EAE618A6C5D625F5C87A1A4)

Subject:

NRC ESEP questions - Calvert Cliffs Attachment 1A - Email 2 Sent Date:

6/18/2015 10:30:36 AM Received Date:

6/18/2015 10:31:17 AM From:

Higgins,Frank:(GenCo-Nuc)

Created By:

frank.higgins@exeloncorp.com Recipients:

"Clark, Jeffrey S.:(GenCo-Nuc)" <Jeffrey.Clark2@exeloncorp.com>

Tracking Status: None "Merritt, Chuck:(GenCo-Nuc)" <chuck.merritt@exeloncorp.com>

Tracking Status: None "Waiters,Sheldon:(GenCo-Nuc)" <sheldon.waiters@exeloncorp.com>

Tracking Status: None "DiFrancesco, Nicholas" <Nicholas.DiFrancesco@nrc.gov>

Tracking Status: None "Wyman, Stephen" <Stephen.Wyman@nrc.gov>

Tracking Status: None Post Office:

exchm-omf-22.exelonds.com Files Size Date & Time MESSAGE 1557 6/18/2015 10:31:17 AM A ESEP Unit 2 Containment Walkdown.pdf 4024600 Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received:

Page 1 CALVERT CLIFFS NUCLEAR POWER PLANT Calvert Cliffs Response to NRC ESEP Report Questions - A Containment Walkdown Photographs - Unit 2

Page 2 Contents UNIT 2.......................................................................................................................................................... 3 Equipment ID No: 2LT-103................................................................................................................... 3 Equipment ID No: 2LT-110X................................................................................................................ 4 Equipment ID No: 2LT-110Y................................................................................................................ 5 Equipment

Description:

Pressurizer Level................................................................................................. 5 Equipment ID No: 2PT-105A................................................................................................................. 6 Equipment

Description:

Pressurizer Pressure............................................................................................ 6 Equipment ID No: 1LT-1124A............................................................................................................... 7 Equipment ID No: 2PT-1013A.............................................................................................................. 8 Equipment ID No: 2PT-1023A.............................................................................................................. 9 Equipment ID No: 2TE-5309.............................................................................................................. 10 Equipment ID No: SIT Tank 21 A........................................................................................................ 11 Equipment ID No: 2LT-321................................................................................................................. 12 Equipment ID No: 2PT-321................................................................................................................ 13 Equipment ID No: SIT Tank 21 B........................................................................................................ 14 Equipment ID No: 2LT-311................................................................................................................. 15 Equipment ID No: SIT Tank 22 A........................................................................................................ 17 Equipment ID No: 2LT-341................................................................................................................. 18 Equipment ID No: 2PT-341................................................................................................................ 19 Equipment ID No: SIT Tank 22 B........................................................................................................ 20 Equipment ID No: 2LT-331................................................................................................................. 21 Equipment ID No: 2PT-331................................................................................................................ 22

Page 3 UNIT 2 Equipment ID No: 2LT-103 Equipment

Description:

Pressurizer Level

Page 4 Equipment ID No: 2LT-110X Equipment

Description:

Pressurizer Level

Page 5 Equipment ID No: 2LT-110Y Equipment

Description:

Pressurizer Level

Page 6 Equipment ID No: 2PT-105A Equipment

Description:

Pressurizer Pressure

Page 7 Equipment ID No: 2LT-1124A Equipment

Description:

Steam Generator Wide Range Level

Page 8 Equipment ID No: 2PT-1013A Equipment

Description:

Steam Generator Safety Channel Pressure

Page 9 Equipment ID No: 2PT-1023A Equipment

Description:

Steam Generator Safety Channel Pressure

Page 10 Equipment ID No: 2TE-5309 Equipment

Description:

Containment Dome Temperature

Page 11 Equipment ID No: SIT Tank 21 A Equipment

Description:

21 A Safety Injection Tank Tank Mounting Typical for all SIT Tanks

Page 12 Equipment ID No: 2LT-321 Equipment

Description:

21 A SIT Level Transmitter

Page 13 Equipment ID No: 2PT-321 Equipment

Description:

21 A SIT Pressure Transmitter

Page 14 Equipment ID No: SIT Tank 21 B Equipment

Description:

21 B Safety Injection Tank

Page 15 Equipment ID No: 2LT-311 Equipment

Description:

21 B SIT Level Transmitter

Page 16 Equipment ID No: 2PT-311 Equipment

Description:

21 B SIT Pressure Transmitter

Page 17 Equipment ID No: SIT Tank 22 A Equipment

Description:

22 A Safety Injection Tank

Page 18 Equipment ID No: 2LT-341 Equipment

Description:

22 A SIT Level Transmitter

Page 19 Equipment ID No: 2PT-341 Equipment

Description:

22 A SIT Pressure Transmitter

Page 20 Equipment ID No: SIT Tank 22 B Equipment

Description:

22 B Safety Injection Tank

Page 21 Equipment ID No: 2LT-331 Equipment

Description:

22 B SIT Level Transmitter

Page 22 Equipment ID No: 2PT-331 Equipment

Description:

22 B SIT Pressure Transmitter