ML15201A020

From kanterella
Jump to navigation Jump to search
Lr Hearing - FW: Draft Phone Call Summary - IPEC LRA
ML15201A020
Person / Time
Site: Indian Point  
Issue date: 07/20/2015
From:
Office of Nuclear Reactor Regulation
To:
References
Download: ML15201A020 (4)


Text

1 IPRenewal NPEmails From:

Wentzel, Michael Sent:

Monday, July 20, 2015 7:50 AM To:

Louie, Richard

Subject:

RE: RE: FW: Draft Phone Call Summary - IPEC LRA

Rich, Sorry for the delay in responding, but I wanted to confirm with tech staff before I did so. Relative to Andys question below, there is no explicit statement in the ISG that states that high-temperature environments are not evaluated to be bounding. However, the scope of AMP XI.M42 states:

Scope of Program: The scope of the program is internal coatings/linings for in-scope piping, piping components, heat exchangers, and tanks exposed to closed-cycle cooling water, raw water, treated water, treated borated water, waste water, fuel oil, and lubricating oil where loss of coating or lining integrity could prevent satisfactory accomplishment of any of the components or downstream components CLB intended functions identified under 10 CFR 54.4(a)(1), (a)(2), or (a)(3).

If high-temperature environments were included, it would have listed environments such as Treated water

>60°C (>140°F) or Closed-cycle cooling water >60°C (>140°F) from GALL Report Section IX.D and the GALL Report AMT line item tables.

I have been holding issuance of the phone call summary. I will add the above discussion to the phone call summary for that particular RAI. If you have any other questions, please let me know.

Thanks, Mike From: Louie, Richard [1]

Sent: Wednesday, July 15, 2015 7:01 AM To: Wentzel, Michael

Subject:

[External_Sender] RE: FW: Draft Phone Call Summary - IPEC LRA Ok, thanks.

From: Wentzel, Michael [2]

Sent: Tuesday, July 14, 2015 3:22 PM To: Louie, Richard

Subject:

RE: FW: Draft Phone Call Summary - IPEC LRA

Rich, Ill try to get some clarification on this and get back to you.
Thanks, Mike From: Louie, Richard [3]

Sent: Monday, July 13, 2015 6:57 AM To: Wentzel, Michael

Subject:

[External_Sender] FW: Draft Phone Call Summary - IPEC LRA Importance: High

2

Mike, Please note below, a comment regarding the attached phone call summary.

Rich From: TAYLOR, ANDREW C Sent: Monday, July 13, 2015 1:28 AM To: Louie, Richard Cc: Lach, David J

Subject:

FW: Draft Phone Call Summary - IPEC LRA Importance: High Rich -

After further review, we have determined that we do have comments on this phone call summary.

We need NRC to specify which statement in LR-ISG-2013-01 indicates that Environments with high temperatures are not evaluated to be bounding within the assumptions of GALL AMP XI.M42 as claimed in DRAFT-RAI 3.0.3-16 Andy Andrew Taylor, P.E.

Acting Manager Entergy Nuclear License Renewal Services 479-858-3531 From: Louie, Richard Sent: Tuesday, July 07, 2015 7:58 AM To: TAYLOR, ANDREW C

Subject:

FW: Draft Phone Call Summary

Andy, Let me know if you have any comments.

Rich From: Wentzel, Michael [4]

Sent: Tuesday, July 07, 2015 8:42 AM To: Louie, Richard

Subject:

Draft Phone Call Summary

Rich, Attached is a draft of the phone call summary from our phone call last week. Please let me know if you have any comments.
Thanks, Mike

3 Michael Wentzel Project Manager NRR/DLR/RPB2 (301) 415-6459 michael.wentzel@nrc.gov

Hearing Identifier:

IndianPointUnits2and3NonPublic_EX Email Number:

5238 Mail Envelope Properties (a10faa25b17445b0ada65cf06db54a57)

Subject:

RE: RE: FW: Draft Phone Call Summary - IPEC LRA Sent Date:

7/20/2015 7:50:26 AM Received Date:

7/20/2015 7:50:27 AM From:

Wentzel, Michael Created By:

Michael.Wentzel@nrc.gov Recipients:

"Louie, Richard" <rlouie@entergy.com>

Tracking Status: None Post Office:

HQPWMSMRS03.nrc.gov Files Size Date & Time MESSAGE 3411 7/20/2015 7:50:27 AM Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received: