ES-401 Record of Rejected K/As Form ES-401-4 Tier /

Group Randomly Selected K/A Reason for Rejection RO Exam 1/2 295022 AA1.04 Unable to write operationally valid question that meets NUREG 1021 LOD requirements. K/A is a Plant Specific and doesnt fully apply to MNGP. Randomly reselected AA1.01 2/1 211000 K3.05 Importance rating <2.5. Randomly reselected K3.03.

2/1 215004 K6.01 K6.01 rejected due to the conceptual overlap with the K/As used for questions 35 & 37. Randomly reselected K6.02.

2/1 261000 K2 Importance ratings <2.5. Randomly reselected Generic.

2/1 261000 2.4.1 Unable to write question for 2.4.1 as there are no immediate actions and/or EOP entry conditions associated with the SBGT system.

Randomly reselected 2.1.27.

2/1 300000 A.1 Importance ratings <2.5. Randomly reselected K.2.

2/2 215001 A3.01 Importance rating <2.5. Randomly reselected A3.03.

2/2 215002 A3.04 Push to check pushbutton is no longer installed at MNGP.

Randomly reselected A3.03.

2/2 223001 2.1.7 Unable to write operationally valid RO question associating Primary Containment with plant performance and reactor behavior.

Randomly reselected 2.1.32.

2/2 226001 Unable to write question without conflicting overlap with questions 13, 15 and 22. Randomly reselected new topic 216000 and new K/A K1.12.

2/2 268000 K3.01 Importance rating <2.5. Randomly reselected K3.04.

2/2 271000 K4.05 Unable to write operationally valid question that meets NUREG 1021 LOD requirements as it relates to Offgas redundancy.

Randomly reselected K4.03. K4.03 importance rating <2.5, randomly reselected K4.08.

2/2 272000 K5.01 Due to implementation of On-Line Noble Chemistry, unable to write operationally valid question that meets NUREG 1021 LOD requirements as it relates to hydrogen injection effects on radiation levels. No other K5 K/A exists, shifted to K6 and randomly reselected K6.03.

ES-401 Record of Rejected K/As Form ES-401-4 Tier /

Group Randomly Selected K/A Reason for Rejection RO Exam - Continued 3/1 2.1.35 Importance rating <2.5. Randomly reselected 2.1.4.

3/2 2.2.6 Unable to write operationally valid RO question. Randomly reselected 2.2.1.

3/2 2.2.19 Importance rating <2.5. Randomly reselected 2.2.6 3/4 2.4.38 Importance rating <2.5. Randomly reselected 2.4.26 SRO Exam 2/1 264000 A2.06 Unable to develop SRO Only written question. Randomly reselected A2.09.

2/1 215000 A2.07 Unable to develop SRO Only valid written question that would meet the time requirements for a written exam. Randomly reselected A2.08.

2/2 201001 2.4.47 Unable to develop SRO Only written question for the system topic 201001. Randomly reselected new system topic 202001.

2/2 219000 A2.13 Unable to develop SRO Only written question for the system topic 219000 as this is an RO task and it overlaps conceptually with RO question #13. Randomly reselected 271000 A2.04.

3 2.1.26 Unable to develop SRO Only written question. Randomly reselected 2.1.39.