SUBJECT:
POINT BEACH NUCLEAR PLANT UNIT 1 - RELIEF REQUEST VR-01; ALTERNATIVES TO CERTAIN INSERVICE TESTING REQUIREMENTS OF THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS CODE OF OPERATION AND MAINTENANCE OF NUCLEAR POWER PLANTS (TAC NO. MF6225)
Dear Mr. McCartney:
By letter dated May 14, 2015 (Agencywide Document Access and Management System Accession No. ML15134A086), NextEra Energy Point Beach, LLC (the licensee), submitted alternative request VR-01 to the U.S. Nuclear Regulatory Commission (NRC). The licensee proposed alternatives to certain inservice testing (IST) requirements of the American Society of Mechanical Engineers (ASME) Code for Operation and Maintenance of Nuclear Power Plants (OM Code), for the IST program at the Point Beach Nuclear Plant (PBNP) Unit 1 for the fifth 10-year IST program interval.
Specifically, pursuant to Title 1 O of the Code of Federal Regulations (10 CFR) Part 50, Section 50.55a(z)(2), the licensee requested to use the proposed alternative in VR-01 on the basis that compliance with the specified requirements of the ASME OM Code would result in hardship or unusual difficulty, without a compensating increase in the level of quality and safety.
As discussed in the attached safety evaluation, the NRC staff determines that for alternative request VR-01, the proposed alternative provides reasonable assurance that the affected component is operationally ready.
Accordingly, the NRC staff concludes that the licensee has adequately addressed all of the regulatory requirements set forth in 10 CFR 50.55a(z)(2). All other ASME OM Code requirements for which relief was not specifically requested and approved in the subject request remain applicable. Therefore, the NRC staff authorizes alternative request VR-01 at PBNP Unit 1 until Refueling Outage 36, which is scheduled to end by June 1, 2016.
If you have any questions, please contact Mahesh Chawla at (301) 415-8371 or Mahesh.Chawla@nrc.gov.
Docket No. 50-266
Enclosure:
Safety Evaluation cc w/enclosure: Distribution via Listserv Sincerely, David L. Pelton, Chief Plant Licensing Branch 111-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION REQUEST NO. VR-01 RELATED TO THE INSERVICE TESTING PROGRAM
1.0 INTRODUCTION
FOR THE FIFTH 10-YEAR INTERVAL NEXTERA ENERGY POINT BEACH. LLC POINT BEACH NUCLEAR PLANT UNIT 1 DOCKET NO. 50-266 By letter dated May 14, 2015 (Agencywide Document Access and Management System Accession No. ML15134A086), NextEra Energy Point Beach, LLC (the licensee), submitted alternative request VR-01 to the U.S. Nuclear Regulatory Commission (NRC). The licensee proposed alternatives to certain inservice testing (IST) requirements of the American Society of Mechanical Engineers (ASME) Code for Operation and Maintenance of Nuclear Power Plants (OM Code), for the IST program at Point Beach Nuclear Plant (PBNP) Unit 1 for the fifth 10-year IST program interval.
Specifically, pursuant to Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Section 50.55a(z)(2), the licensee requested to use the proposed alternative in VR-01 on the basis that compliance with the specified requirements of the ASME OM Code would result in hardship or unusual difficulty, without a compensating increase in the level of quality and safety.
2.0 REGULATORY EVALUATION
Section 50.55a(f), "lnservice testing requirements," of 1 O CFR requires, in part, that IST of certain ASME Code Class 1, 2, and 3 components must meet the requirements of the ASME OM Code and applicable addenda.
Section 50.55a(z) of 10 CFR, states, in part, that alternatives to the requirements of paragraph (f) of 1 O CFR 50.55a may be authorized by the NRC if the licensee demonstrates that (1) the proposed alternative provides an acceptable level of quality and safety, or (2) compliance with the specified requirements would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety.
The PBNP Unit 1 fifth 10-year IST interval began on September 1, 2012. The IST program complies with the ASME OM Code, 2004 Edition through 2006 addenda.
Enclosure Based on the above, and subject to the NRC's findings with respect to authorizing the proposed alternatives to the ASME OM Code given below, the NRC staff finds that regulatory authority exists for the licensee to request, and the Commission to authorize, the alternatives requested by the licensee.
3.0 TECHNICAL EVALUATION
3.1 Licensee's Alternative Request VR-01 ASME Code Components Affected This request applies to the test frequency specifications of the ASME OM Code for the below listed relief valves.
Valve Number Description Class Next Test Due Date 1 P-1 B Reactor Coolant Pump (RCP) 1CC-00763B Component Cooling Water Return Header 2
9/9/2015 Relief Valve
Applicable Code Edition and Addenda
PBNP Unit 1 is currently in the fifth 10-year IST interval, which began on September 1, 2012.
The code of record for the fifth 10-year IST interval is ASME OM Code, 2004 Edition through 2006 Addenda.
Applicable Code Requirements ASME OM Code, Mandatory Appendix I, "lnservice Testing of Pressure Relief Devices in Light-Water Reactor Nuclear Power Plants," Section 1-1350, 'Test Frequency, Classes 2 and 3 Pressure Relief Valves."
Section l-1350(a) 10-year test interval, Classes 2 and 3 pressure relief valves, with the exception of pressurized-water reactor main steam safety valves, shall be tested every 10 years, starting with initial electric power generation. No maximum limit is specified for the number of valves to be tested during any single plant operating cycle; however, a minimum of 20 percent of the valves from each valve group shall be tested within any 48-month interval.
This 20 percent shall consist of valves that have not been tested during the current 10-year test interval, if they exist. The test interval for any individual valve shall not exceed 10 years.
Reason for Request
Relief valve 1 CC-007638, 1 P-1 B RCP Component Cooling Return Header Relief Valve testing was to occur in the Unit 1 Refueling Outage 35 (U1R35) in October 2014. The valve is one of four valves in Group 1-6 of the PBNP IST program. The valve was inadvertently omitted from the refueling outage schedule. This omission is being reviewed in the corrective action program.
The omission was discovered on October 27, 2014. The component cooling water system had already been filled and vented in preparation for start-up. Plant personnel had also identified that no spare parts were available to support testing. To align the component cooling water system to support relief valve testing and perform testing without adequate spares would have placed PBNP at a significant disadvantage.
1 CC-007638 was last tested on September 12, 2005. The 10-year test interval will expire on September 12, 2015. The next scheduled opportunity for testing will be in Unit 1 Refueling Outage U1R36, which is scheduled to begin on March 12, 2016. A 7-month extension beyond the 10-year testing interval is requested to allow time for testing to be completed.
In accordance with 1 O CFR 50.55a(z)(2), PBNP requests relief from applicable ASME Code requirements for 1 CC-007638 relief valve testing until the next Unit 1 Refueling Outage U1 R36.
NUREG-1482, Revision 2, "Guidelines for lnservice Testing at Nuclear Power Plants,"
Section 2.5, "Relief Request and Proposed Alternatives," states that a licensee may propose alternatives to ASME Code requirements if compliance with the specified requirement would result in hardship or unusual difficulty, without compensating increase in level of quality and safety.
Performance of this testing would require the isolation of component cooling water to the 1 P-1 B RCP. This cannot be performed with the plant on-line. Performance of this testing would require the plant to incur additional thermal cycles and the stopping and starting of several major plant components, which induces additional wear and risk unnecessarily.
Proposed Alternative and Basis for Use The proposed alternative is to perform testing of the subject valve during the next Refueling Outage U1 R36, which is scheduled to start on March 12, 2016. This is the next opportunity to perform the required testing.
Duration of Proposed Alternative The proposed alternative will be utilized until the end of the next Refueling Outage U1 R36, scheduled for March 2016.
3.2
NRC Staff Evaluation
Historically, licensees have applied, and the NRC staff has accepted, the standard technical specification (TS) definitions for IST intervals (including allowable interval extensions) to ASME OM Code required testing (NUREG-1482, Revision 2, Section 3.1.3, "Scheduling of lnservice Tests"). Recently, the NRC staff reconsidered the allowance of using TS testing intervals and interval extensions for IST not associated with TS surveillance requirements (SRs). As noted in Regulatory Issue Summary (RIS) 2012-10, "NRC Staff Position on Applying Surveillance Requirements 3.0.2 and 3.0.3 to Administrative Controls Program Tests," the NRC determined that programmatic test frequencies cannot be extended in accordance with the TS SR 3.0.2.
Following this development, the NRC staff sponsored and co-authored an ASME OM Code inquiry and Code Case to modify the ASME OM Code to include TS-like test interval definitions and interval extension criteria. The resultant ASME Code Case OMN-20 was approved by the ASME Operation and Maintenance Standards Committee on February 15, 2012, with the NRC representative voting in the affirmative. ASME Code Case OMN-20 was subsequently published in conjunction with the ASME OM Code, 2012 Edition.
The licensee does not propose to adopt Code Case OMN-20, but rather proposes a one-time extension to the test interval for the subject valve that is approximately the same test interval extension sanctioned by OMN-20. For 1 CC-00763B, the licensee proposes to extend the interval from September 9, 2015, until the beginning of the next Refueling Outage U1 R36 on March 12, 2016 (6 months and 3 days), whereas OMN-20 would allow an extension of up to 6 months. The licensee further specified that the required testing would be performed during Refueling Outage U1 R36, which is scheduled to end by approximately June 1, 2016.
Requiring the licensee to meet ASME OM Code requirements without an allowance for frequency tolerance results in a hardship without a compensating increase in the level of quality and safety. Based on the prior acceptance by the NRC staff of the OMN-20 interval extension criteria, the staff finds that implementation of the test interval extension criteria proposed by the licensee is acceptable and provides reasonable assurance of operational readiness of the subject valve.
4.0 CONCLUSION
As set forth above, the NRC staff determines that for alternative request VR-01, the proposed alternative provides reasonable assurance that the affected component is operationally ready.
Accordingly, the NRC staff concludes that the licensee has adequately addressed all of the regulatory requirements set forth in 10 CFR 50.55a(z)(2). All other ASME OM Code requirements for which relief was not specifically requested and approved in the subject request remain applicable. Therefore, the NRC staff authorizes alternative request VR-01 at PBNP Unit 1 until Refueling Outage U1R36, which is scheduled to end by June 1, 2016.
Principal Contributor: John Billerbeck Date: June 24, 2015
If you have any questions, please contact Mahesh Chawla at (301) 415-8371 or Mahesh.Chawla@nrc.gov.
Docket No. 50-266
Enclosure:
Safety Evaluation Sincerely, IRA KGreen for!
David L. Pelton, Chief Plant Licensing Branch 111-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation cc w/enclosure: Distribution via Listserv DISTRIBUTION:
PUBLIC LPL3-1 R/F RidsNrrDorlDpr Resource RidsNrrDorllpl3-1 Resource RidsPMPointBeach Resource RidsNrrLAABaxter Resource RidsNrrDeEpnb Resource RidsRgn3MailCenter Resource RidsACRS_MailCTR Resource JBillerbeck, NRR LRonewicz, NRR RidsNrrDeEpnb Resource ADAMS A ccess1on N o.: ML15161A535
- b 1y memo OFFICE DORL/LPL3-1 /PM DORL/LPL3-1/LA DE/EPNB/BC*
DORL/LPL3-1 /BC NAME MChawla LRonewicz DAiiey (KGreen for) DPelton DATE 6/15/2015 6/12/2015 5/30/2015 6/24/2015 OFFICIAL RECORD COPY