Entergy Operations, Inc.
River Bend Station 5485 U.S. Highway 61 N St. Francisville, LA 70775 RBG-47566 May 5, 2015 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555
Subject:
Additional Information on River Bend Station Recommendation 2.1 Flood Hazard Re-evaluation River Bend Station - Unit 1 Docket No. 50-458 License No. NPF-47
Reference:
- 1. Entergy Letter RBG-47447, Response to Request for Information Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, dated March 12, 2014
- 2. River Bend Station Recommendation 2.1 Flood Hazard Re-evaluation Request for Additional Information, email dated April 27, 2015 (Tekia Govan to Danny Williamson)
RBF1-15-0069
Dear Sir or Madam:
In Reference (1), Entergy Operations, Inc. (Entergy) submitted a response to the Near Term Task Force Recommendation 2.1: Flooding Hazard Re-evaluation Report in response to the Nuclear Regulatory Commission's request for information pursuant to Title 10 of the Code of Federal Regulations 50.54(f).
In reviewing the Flooding Hazard Re-evaluation Report, NRC determined that additional information was required to complete the review (Reference 2), specifically, electronic copies of site survey documentation. The enclosure to this letter is a compact disc containing that information.
There are no new commitments contained in this submittal. If you have any questions, please contact Mr. Joseph Clark at 225-381-4177.
Respectfully, N. Todd Brumfield Director - Regulatory & Performance Improvement NTB/dhw
Enclosure:
One CD with requested information
RBG-47566 May 5, 2015 Page 2 of 2 cc:
Ms. Tekia Govan (w/ enclosure)
U.S. Nuclear Regulatory Commission MS 13C05 11555 Rockville Pike Rockville, MD 20852-2738 U.S. Nuclear Regulatory Commission (w/o enclosure)
Region IV 1600 East Lamar Blvd.
Arlington, TX 76011-4511 NRC Resident Inspector (w/o enclosure)
R-SB-14 Central Records Clerk (w/o enclosure)
Public Utility Commission of Texas 1701 N. Congress Ave.
Austin, TX 78711-3326 Department of Environmental Quality (w/o enclosure)
Office of Environmental Compliance Radiological Emergency Planningand Response Section ATTN: JiYoung Wiley P.O. Box 4312 Baton Rouge, LA 70821-4312 Mr. Alan Wang, Project Manager (w/o enclosure)
U.S. Nuclear Regulatory Commission MS 0-881 11555 Rockville Pike Rockville, MD 20852-2738