UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the matter of Pacific Gas and Electric Company Docket Nos. 50-275-LR Diablo Canyon Nuclear Power Plant 50-323-LR Units 1 and 2 SAN LUIS OBISPO MOTHERS FOR PEACES MOTION TO FILE NEW CONTENTIONS REGARDING ADEQUACY OF SEVERE ACCIDENT MITIGATION ALTERNATIVES ANALYSIS FOR DIABLO CANYON LICENSE RENEWAL APPLICATION I.
INTRODUCTION Pursuant to 10 C.F.R. §§ 2.309(c), 2.309(f)(1), and 2.309(f)(2), San Luis Obispo Mothers for Peace (SLOMFP) seeks leave to file two new contentions challenging the adequacy of Pacific Gas & Electric Companys (PG&Es) Severe Accident Mitigation Alternatives (SAMA) Analysis for the proposed renewal of the Diablo Canyon nuclear power plant (DCNPP) operating license to satisfy the National Environmental Policy Act (NEPA) and U.S. Nuclear Regulatory Commission (NRC) implementing regulations.1 In Contention C (Inadequate Consideration of Seismic Risks in SAMA Analysis),
SLOMFP contends that PG&Es SAMA Analysis is inadequate to satisfy NEPA because it proposes to rely on the results of PG&Es recently-submitted and seriously deficient post-Fukushima seismic risk analysis for its evaluation of the cost-effectiveness of measures to mitigate earthquake impacts. Contention C is supported by the attached Declaration of Dr.
David D. Jackson, Professor of Geophysics Emeritus at the University of California at Los Angeles (attached). Contention D (Inadequate Discussion of Flooding Risk in SAMA Analysis) asserts that the SAMA Analysis wrongly fails to consider flooding risks to safety equipment
1 The SAMA Analysis is presented in Appendix F to PG&Es Amended Environmental Report (submitted February 25, 2015) (ER).
2
posed by local intense precipitation or LIP flooding events. These LIP flooding risks were identified in PG&Es own post-Fukushima flood hazard analysis.2 As discussed below in Section II, SLOMFPs contentions meet the NRCs requirements for admissibility of contentions. As further discussed in Section III, SLOMFP also has good cause for filing the contentions after the initial deadline, which passed in 2010.
II.
CONTENTIONS Contention C. Inadequate Consideration of Seismic Risk in SAMA Analysis
- 1.
Statement of Contention PG&Es SAMA Analysis (Appendix F of PG&Es Amended ER) is inadequate to satisfy the National Environmental Policy Act (NEPA) or NRC implementing regulation 10 C.F.R. § 51.53(c)(ii)(L) because PG&Es evaluation of potential mitigation measures is not based on a sufficiently rigorous or up-to-date analysis of seismic risks. As a result, PG&Es evaluation of the comparative costs and benefits of measures to prevent or mitigate the effects of a severe earthquake does not sufficiently credit the cost-effectiveness of mitigation measures.
While PG&E claims that the results and insights of its 2014 interim probabilistic risk analysis (PRA) (labeled DCO3) are reasonable for the purposes of a SAMA analysis (Amended ER at F-34), by PG&Es own admission, DCO3 is only an interim PRA. Id. In addition, it is not sufficiently rigorous or updated to support the SAMA analysis.
Nor does PG&Es promise to update the DCO3 with the results of its 2015 seismic hazards analysis3 cure the inadequacy of DCO3 to support PG&Es SAMA Analysis, because
2 Contentions C and D follow two contentions filed by SLOMFP on April 6, 2015: Contention A (Inadequate Consideration of Energy Alternatives) and Contention B (Failure to Conduct Cost-Benefit Analysis of Energy Alternatives).
3 PG&Es 2015 seismic hazards analysis consists of two documents: Pacific Gas and Electric Co., Seismic Hazard and Screening Report, Diablo Canyon Power Plant Units 1 and 2 (SHS
3
PG&Es 2015 seismic hazards analysis is also insufficiently rigorous and relies on outdated or unjustified methods and assumptions. Given the inadequacies of PG&Es seismic hazards analysis, to merely cite its results in a revised SAMA Analysis would not be sufficient to ensure the adequacy of the SAMA Analysis to evaluate potential mitigation measures for severe seismic accidents. Instead, PG&E must cure the significant defects in the underlying data and analyses.
- 2.
Statement of Basis for the Contention
- a.
NEPA requirements The core requirement of NEPA is that for any federal action with a significant adverse effect on the human environment, federal agencies must prepare an environmental impact statement (EIS) which includes a detailed statement regarding:
(i) the environmental impact of the proposed action, (ii) any adverse environmental effects which cannot be avoided should the proposal be implemented, (iii) alternatives to the proposed action, (iv) the relationship between local short-term uses of man's environment and the maintenance and enhancement of long-term productivity, and (v) any irreversible and irretrievable commitments of resources which would be involved in the proposed action should it be implemented.
San Luis Obispo Mothers for Peace, 449 F.3d 1016, 1020 (2006) (citing Dept. of Transp. v. Pub.
Citizen, 541 U.S. 752, 756 (2004), 42 U.S.C. § 4332(2)(C)). NRC regulations also require that an NRC application for operating license renewal must be supported by an environmental report prepared by the applicant (10 C.F.R. § 51.53(c)) and a supplemental EIS prepared by the NRC Staff. 10 C.F.R. § 51.95(c).
Report), submitted by letter from Barry S. Allen, PG&E to NRC, re: Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding the Seismic Aspects of Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident:
Seismic Hazard and Screening Report (Mar. 11, 2015); and PG&Es Seismic Source Characterization for the Diablo Canyon Power Plant, San Luis Obispo County, California; report on the results of a SSHAC level 3 study (Rev. A, March 2015) (SSC Report).
4
An EIS must provide decision-makers with a reasonable array of alternatives for avoiding or mitigating the environmental impacts of the proposed action. Idaho Sporting Cong. v.
Thomas, 137 F.3d 1146, 1151 (9th Cir. 1998) (citing Robertson v. Methow Valley Citizens Council, 490 U.S. 332, 352 (1989)). With respect to renewal of reactor operating licenses, NRC regulations specifically require a discussion of alternatives to mitigate severe accidents. 10 C.F.R. §§ 51.53(c)(3)(ii)(L), 51.95(c)(2). Probability figures used in a SAMA analysis must be adequate to support the reasoned consideration of alternatives. Duke Energy Corp. (McGuire Nuclear Station, Units 1 and 2; Catawba Nuclear Station, Units 1 and 2), CLI-02-17, 56 NRC 1, 7 (2002). In addition, the SAMA Analysis must consider relevant information from outside sources. Id. at 8; Pacific Gas and Electric Co. (Diablo Canyon Nuclear Power Plant, Units 1 and 2), CLI-11-11, 74 NRC 427, 443 (2011). Finally, an Environmental Report or EIS must address new and significant information that was not previously addressed in an EIS for the facility.
10 C.F.R. §§ 51.53(c)(iv), 51.92(a)(2).
- b.
Inadequacy of DCO3 to support SAMA Analysis PG&E asserts that the interim results and insights from the DC03 model are reasonable for the purposes of a SAMA analysis because:
At the time of the 2013 Seismic Peer Review, the Turbine Building Shear Wall fragility had been updated based on the latest hazard spectral information, which was updated with the Shoreline Fault. The fragility analysis for other SSCs was based on the LTSP.
The LTSP fragility curves are acceptable for use in DC03 because no scaling is necessary for use with the updated hazard spectral information. The LTSP fragility curves are the same shape (+/-1 0°/o) in the period of interest (3-8.5Hz) and there are no components in the PRA model in the 1-3Hz range. In addition, the 2014 Central Coastal California Seismic Imaging Project Report (Reference 53) was a deterministic analysis that did not change the inputs to the seismic PRA.
Amended ER at F-34. While PG&E claims to have relied on the latest hazard spectral information for its 2013 update to the Turbine Building Shear Wall fragility, that information
5
does not include the 2015 SHS Report or the 2015 SSC Report; and therefore the spectral information is not, in fact, the latest. As PG&E implicitly acknowledges, the latest consists of the probabilistic seismic hazards assessment prepared by PG&E in response to the NRCs post-Fukushima Request for Information. PG&E must consider this information and ensure it is adequate to support the SAMA Analysis. Duke Energy Corp., 56 NRC at 7 (requiring adequate probability figures to support a SAMA analysis); Pacific Gas and Electric Co., 74 NRC at 443 (SAMA Analysis must consider relevant information from outside sources); 10 C.F.R. §§ 51.53(c)(iv), 51.92(a)(2) (Environmental Reports and EISs must address new and significant information that was not previously addressed.)
- c.
Inadequacy of seismic hazards assessment results to support SAMA analysis The results that PG&E proposes to use to update its SAMA Analysis come from a site-specific probabilistic seismic hazard assessment that PG&E prepared in response to the NRCs March 12, 2012 Request for Information, issued pursuant to 10 C.F.R. § 50.54(f). As described by PG&E:
The assessment used an updated seismic source characterization (SSC) model and an updated GMC [ground motion characterization] model as basic inputs. The SSC and GMC studies were undertaken to fulfill the NRC requirement that PG&E conduct a probabilistic seismic hazard assessment using SSHAC [Senior Seismic Hazards Analysis Committee] Level 3 procedures for DCPP, as specified by the NRC (NRC 2012). Thus, the SSC [seismic source characterization] and GMC models were developed using processes that are appropriate for a SSHAC Level 3 study, as described in NUREG/CR-6372 (NRC 1997), and the detailed implementation guidance provided in NUREG-2117 (NRC 2012b). Both the SSC and GMC models represent new or "replacement" models according to the definitions and instructions in NUREG-2117. The SSC model describes the future earthquake potential (e.g., magnitudes, locations, and rates) for the region surrounding the DCPP site, and the GMC model describes the distribution of the ground motion as a function of magnitude, style of faulting, source-to-site geometry and reference site condition.
SHS Report at 15.
6
PG&E also states that it will address the effect of the seismic hazards assessment results on the SAMA Analysis. Amended ER at F-34. Incorporation of the results of the seismic hazards analysis would not satisfy NEPA or NRC implementing regulations, however, because the data and analyses underlying those results are faulty in two fundamental respects:
failure to account for nearby earthquakes, and failure to account for potentially large earthquakes.
(i)
Failure to account for nearby earthquakes First, PG&Es seismic hazards analysis fails to account for reasonably foreseeable earthquakes located nearer to the DCPP than PG&E has assumed. For instance, the seismic stations used to locate earthquakes on the Shoreline Fault are all onshore, east of the fault, so that the faults east-west location is highly uncertain. Thus the fault could be closer to or further from DCPP than assumed in DC03. The most effective solution would be to install offshore seismic stations west of the fault and record earthquakes long enough to infer the fault location accurately. Barring that, PGE must consider both nearer and farther locations of the Shoreline fault with realistic weights that reflect the fault location uncertainty.
In this context, PGE also wrongly assumes that major earthquakes are located exactly on simplified versions of mapped fault traces. While PG&E considers alternative versions of fault geometry models (FGMs) for some faults (see SSC Report, section 6.3.1), PG&E makes no provision for large off-fault earthquakes. Smaller earthquakes are accounted for in the Areal Source Zones, but their magnitudes are limited to 6.8 or 6.9 in the Local Areal Zone (see SSC Report, Figure 14-1), most relevant to seismic hazard.4 PG&E disregards that fact that
4 These imposed limitations on potential magnitude are arbitrary and unjustified, as discussed below in subsection ii.
7
earthquakes larger than those limits could occur within the Local Areal Zone, causing strong ground motion not yet accounted for.
In addition, PG&E does not follow the well-established method for California earthquake mapping of showing earthquake locations in a broad zone that covers a few kilometers on either side of major faults. (Hauksson et al, 2012; Powers and Field, UCERF3 Appendix O, 2013; Simpson, et al, 2006).5 In the Uniform California Earthquake Rupture Forecast (Field, 2014a, 2014b) major faults are considered to have a width 12 km on both sides of major faults, with the implication that earthquakes associated with those faults could occur anywhere in those broad zones. With this understanding, earthquakes associated with the Hosgri fault, for example, could occur much closer to the DCPP than the assumed fault geometry under any of the options considered by PGE.
As a result of PG&Es outdated and non-conservative assumptions about the location of earthquakes, the hazard curves in the SSC Report underestimate the shaking that may be caused by nearby earthquakes. The amount of PG&Es underestimate is potentially significant, and therefore must be evaluated by further study before PG&E may reasonably rely on the SSC Reports results in its SAMA Analysis.6 ii.
Failure to account for potential large earthquakes Second, even for the faults that PG&E does recognize and analyze, PG&E fails to account for recent data and models showing that earthquakes on given faults may be much larger
5 While PG&E estimates most important faults like Hosgri and Los Osos have widths of 2 km or more, its hazard calculations do not include those widths.
6 PG&E could, for instance, apply a stochastic fault model (Hiemer et al., 2014a and 2014b) to deal with these problems. The stochastic fault model is recent, but it overcomes the assumption that major quakes occur exactly on faults, and it has been adopted for use in the SHARE project in Europe (Hiemer et al., 2014b). Alternately, hazard calculations could include earthquake scenarios near but not exactly on mapped faults. This would be most important on nearby faults such as Hosgri and Shoreline.
8
than previously assumed. For instance, PG&E estimates the most likely maximum magnitude for earthquakes in the Local Areal Zone to be 6.8 (SSC Report, Table 13-9). PG&E does allow that the Shoreline fault might participate as a branch of a larger earthquake on the Hosgri, but the resulting ground shaking is assumed to be less than that of a larger earthquake that extends the Shoreline fault, as it could. Experience shows that earthquake magnitudes may be much larger.
PG&Es understatement of magnitude stems from its reliance on scaling relations, which are equations relating magnitude to rupture length or rupture area. The most commonly cited equations, which are used heavily by PG&E, are from Wells and Coppersmith (1994).
PG&E uses them to estimate the maximum magnitude of a fault from its mapped length. But scaling of earthquake magnitudes from fault geometry has been demonstrated to be unsupportable, because the mapped fault length is no limit to the ultimate rupture length. Many earthquakes have ruptures exceeding the length of the faults on which they started. Even PG&E implicitly acknowledges this: examples listed in the SSC Report at page 6-6 include the 2002 Denali, AK (magnitude 7.9), the 1992 Landers, CA (magnitude 7.3), and the 1999 Hector Mine, CA (magnitude 7.1). Other major earthquakes occur on previously unknown faults, even in areas with extensive prior geological study: the 1989 Loma Prieta earthquake (magnitude 7.1; Spudich, 1996); the 1994 Northridge, CA (magnitude 6.7); and the 2010 Darfield, NZ (magnitude 7.1) earthquakes. Perhaps the most astounding example was the 2012 magnitude 8.6 strike-slip earthquake off the coast of northern Sumatra (Ishii et al., 2013). Nevertheless, PG&E disregards this information and unjustifiably relies on the scaling relationships to estimate maximum magnitude from fault length.
Perhaps the most significant example of PG&Es unjustifiable reliance on the scaling assumption is in the Local Areal Zone, where PG&E has concluded that the virtual faults there
9
must be confined to a length of 50 km, implying a most probable maximum magnitude of 6.8 for strike slip earthquakes and 6.9 for reverse slip (thrust) earthquakes (SSC Report, Table 13-9, page 13-29). PG&Es assumption of a 50 km fault length is purely subjective, and not based on any observed fault length. More importantly, it is irrelevant because earthquake rupture length could exceed the fault length there just as it has in the cases listed above. Similarly, the length assumed by PG&E for the Shoreline Fault is based only on circumstantial evidence, and there is no evidence that earthquakes could not rupture well beyond its boundaries. PG&E does include in its source model the possibility that the Shoreline Fault might rupture in combination with the Hosgri fault. However, strong ground motion at DCPP due to a simpler large (magnitude above 6.8) earthquake extending the Shoreline Fault may be significantly different.
Including such a possible source in a revised SSC is needed to resolve that question.
In some cases, PGE has under-estimated maximum magnitude by applying scaling relationships not just to fault length, but to segment length. Segments are shorter lengths of faults that are assumed to contain the entire rupture; that is, rupture starting within a segment must stop at the next segment boundary. An earthquake presumed to rupture one full segment is referred to as a characteristic earthquake. The characteristic earthquake model assumes that most large earthquakes on a fault are characteristic earthquakes. But both the characteristic earthquake model and the segmentation model have been discredited, most notably by the massive Tohoku, Japan earthquake of 2011 (magnitude 9.0), which destroyed the Fukushima Nuclear Power Plant and led to the very seismic hazard analysis that PG&E has reported on in the SSC Report and SHS Report. Before the Tohoku earthquake happened, the Japanese government estimated, based on a segmentation model, that the upper magnitude limit there was on the order of 8.0.
The actual magnitude of 9.0 was a surprise to those who held on to the segmentation model
10
(Kagan and Jackson, 2013; Stein, et al., 2011). The catastrophic 2004 Banda Aceh (Sumatra )
earthquake (M 9.1; Banerjee, 2004) also violated many so-called segment boundaries and exceeded the scale of magnitudes implied by the characteristic earthquake assumption.
One reason that the segmentation model has been discredited is that it assumes that hazard is greatest near the segment boundaries, because a site there would be shaken strongly by earthquakes on either of the joined segments. A corollary of that assumption is that sites near the middle of a segment are assumed to be less hazardous because they are less shaken by earthquakes on adjoining segments. But there is no direct evidence that ruptures repeatedly stop at the ends of segments, nor is there evidence of more frequent strong shaking near the boundaries. Instead, PG&Es assumptions are purely subjective. In this context, it is important to recognize that the authors of the UCERF3 report took care to eliminate or reduce the effect of the segmentation model and segment boundaries (e.g. Field et al., 2014). As stated in the first two sentences of the abstract:
The 2014 Working Group on California Earthquake Probabilities (WGCEP14) present the time-independent component of the Uniform California Earthquake Rupture Forecast, Version 3 (UCERF3), which provides authoritative estimates of the magnitude, location, and time-averaged frequency of potentially damaging earthquakes in California. The primary achievements have been to relax fault segmentation and include multifault ruptures, both limitations of UCERF2.
Some boundaries were retained in UCERF3 to minimize the changes from previous models, but not because of empirical evidence. As the authors also stated in the abstract:
UCERF3 is still an approximation of the system, however, and the range of models is limited (e.g., constrained to stay close to UCERF2)... Although UCERF3 fits the data better than UCERF2 overall, there may be areas that warrant further site-specific investigation.7
7 UCERF3 maintained some vestiges of segmentation so as not to introduce changes too quickly. The effect of segmentation in the UCERF3 report was not profound, however, because UCERF3 did not intend its use for site-specific application.
11
UCERF3 maintained some vestiges of segmentation so as not to introduce changes too quickly.
The effect of segmentation in the UCERF3 report was not profound because UCERF3 did not intend use for site specific application. In the case of DCPP, the segments and boundaries assumed by PG&E, especially those on the Hosgri Fault, are close enough to the source to artificially increase or decrease the calculated ground motion, PG&E should have abandoned the segmentation model in order to more accurately model earthquake hazards.
The characteristic model implies a higher earthquake rate at characteristic magnitudes than predicted by the Gutenberg-Richter (GR) model, its prime competitor. The GR model posits that the frequency of earthquakes decreases exponentially with increasing magnitude, such that earthquakes of magnitude 7 and above, for example, would be about 10 times less frequent than those of magnitude 6 and above. The GR model is consistent with the magnitudes of quakes in most regional catalogs throughout the world. The characteristic model implies that earthquakes at the characteristic magnitude should be up to 40 times more frequent than predicted by GR (Schwartz and Coppersmith, 1984) and it is generally assumed to apply to individual faults. When both models are fit to the same amount of slip on a known fault, it follows that the characteristic model predicts fewer earthquakes both above and below the characteristic magnitude range. Wesnousky, (1994), Kagan (1996) and many others have debated the issue at length. Page and Felzer (2015, in press) show that the GR model is quite consistent with earthquakes on the San Andreas fault. The failure of the segmentation model as noted above, and the very subjective nature of the way segment boundaries must be assigned, makes the characteristic model and its implied magnitude distribution very dubious.
To address this deficiency, PG&E should take several measures: give more weight to GR magnitude distribution, using realistic (higher) maximum magnitudes; randomly locate
12
ruptures, with some extending off the ends of faults; and take a stochastic approach as in Hiemer et al (2014, 2015). When both models are constrained to match the same slip rates and a realistic maximum magnitude greater than the characteristic magnitude is assigned, the GR model will imply lower rates of characteristic magnitude events but higher rates at smaller and larger magnitudes. Thus replacing the characteristic assumption with a reasonable GR model could increase or decrease the calculated hazard at different spectral frequencies, depending on details that can only be determined with proper modeling. Similarly, the effect of replacing segmentation with randomized locations of earthquakes on faults may increase or decrease hazard at different spectral frequencies depending on the locations of assumed segment geometry relative to DCPP. Again, accurate modeling is required to know the effect. In any case, the assumptions of segmentation and characteristic earthquakes should be abandoned because they are in conflict with observed earthquakes as listed above.
- 3.
Demonstration that the contention is within the scope of the proceeding This contention is within the scope of the Diablo Canyon license renewal proceeding because it challenges the adequacy, under NEPA and NRC implementing regulations, of the SAMA Analysis required for the re-licensing of Diablo Canyon.
- 4.
Demonstration that the contention is material to the findings the NRC must make to re-license Diablo Canyon The contention is material to the findings that the NRC must make in order to license this reactor because it challenges the environmental analysis that the NRC will rely on for its NEPA findings in the DCNPP license renewal proceeding.
13
- 5.
Concise statement of the facts or expert opinion supporting the contention, along with appropriate citations to supporting scientific or factual materials The facts and expert opinion on which SLOMFP relies are summarized in Section 2 (basis statement) above. They are supported by the Declaration of Dr. David D. Jackson, attached. The following is a list of references relied on in the contention:
(Banerjee et al., 2004)
Paramesh Banerjee, Fred Pollitz, B. Nagarajan, and Roland Bürgmann, Coseismic Slip Distributions of the 26 December 2004 Sumatra-Andaman and 28 March 2005 Nias Earthquakes from GPS Static Offsets, Bulletin of the Seismological Society of America, January 2007, v. 97, p. S86-S102,doi:10.1785/0120050609 (Bird et al., 2004)
Peter Bird, P., and Yan Y. Kagan, "Plate-tectonic analysis of shallow seismicity: apparent boundary width, beta, corner magnitude, coupled lithosphere thickness, and coupling in seven tectonic settings", Bull. Seismol. Soc. Amer., 94(6), 2380-2399, 2004. (plus electronic supplement), doi:10.1785/0120030107 (Field et al., 2014)
Edward H. Field, Ramon J. Arrowsmith, Glenn P. Biasi, Peter Bird, Timothy E. Dawson, Karen R. Felzer, David D. Jackson, Kaj M. Johnson, Thomas H. Jordan, Christopher Madden, Andrew J.Michael, Kevin R. Milner, Morgan T. Page, Tom Parsons, Peter M.
Powers, Bruce E. Shaw, Wayne R. Thatcher, Ray J. Weldon II, and Yuehua Zeng, Uniform California Earthquake Rupture Forecast, Version 3 (UCERF3)The Time-Independent Model, Bulletin of the Seismological Society of America, Vol. 104, No. 3, pp. 1122-1180, June 2014, doi: 10.1785/0120130164 (Field et al., 2015)
Edward H. Field, Glenn P. Biasi, Peter Bird, Timothy E. Dawson, Karen R. Felzer, David D. Jackson, Kaj M. Johnson, Thomas H. Jordan, Christopher Madden, Andrew J. Michael, Kevin R. Milner, Morgan T. Page, Tom Parsons, Peter M. Powers, Bruce E. Shaw, Wayne R. Thatcher, Ray J. Weldon II, and Yuehua Zeng, Long-Term Time-Dependent Probabilities for the Third Uniform California Earthquake Rupture Forecast (UCERF3), Bulletin of the Seismological Society of America, Vol. 105, No. 2A, pp. 511-543, April 2015, doi: 10.1785/0120140093 (Hardebeck, 2013)
Jeanne L. Hardebeck, Geometry and Earthquake Potential of the Shoreline Fault, Central California, Bulletin of the Seismological Society of America, Vol. 103, No. 1, pp. 447-462, February 2013, doi: 10.1785/0120120175 (Hauksson et al., 2011)
14
Egill Hauksson, Wenzheng Yang, and Peter M. Shearer, Waveform Relocated Earthquake Catalog for Southern California (1981 to June 2011), Bulletin of the Seismological Society of America, Vol. 102, No. 5, pp. 2239-2244, October 2012, doi:
10.1785/0120120010 (Hiemer et al., 2013)
Stefan Hiemer, David D. Jackson, Qi Wang, Yan Y. Kagan, Jochen Woessner, Jeremy D.
Zechar, and Stefan Wiemer, A Stochastic Forecast of California Earthquakes Based on Fault Slip and Smoothed Seismicity, Bulletin of the Seismological Society of America, Vol. 103, No. 2A, pp. 799-810, April 2013, doi: 10.1785/0120120168 (Hiemer et al., 2014)
S. Hiemer, J. Woessner,1 R. Basili, L. Danciu,1 D. Giardini and S. Wiemer, A smoothed stochastic earthquake rate model considering seismicity and fault moment release for Europe, Geophys. J. Int. (2014) 198, 1159-1172 doi: 10.1093/gji/ggu186 (Ishii et al., 2013)
Miaki Ishii, Eric Kiser, and Eric L. Geist, Mw 8.6 Sumatran earthquake of 11 April 2012:
Rare seaward expression of oblique subduction. Geology, March 2013, v. 41, p.319-322 (First published on January 17, 2013).
(Kagan, 1996)
Kagan, Y. Y. (1996), Comment on The Gutenberg-Richter or characteristic earthquake distribution,which is it?, by S. G. Wesnousky, Bull. Seismol. Soc. Am., 86, 275-284.
(Kagan and Jackson, 2013)
Kagan, Y. Y., and D. D. Jackson (2013), Tohoku earthquake: a surprise?, Bull. Seismol.
Soc. Am.,103, 1181-1194.
(Powers and Jordan, 2010)
Peter M. Powers and Thomas H. Jordan, Distribution of seismicity across strikeslip faults in California, JOURNAL OF GEOPHYSICAL RESEARCH, VOL. 115, B05305, doi:10.1029/2008JB006234, 2010 (Powers and Fields, 2013)
Powers, P., and N. Field, UCERF3 Appendix O, Gridded Seismicity Sources, http://pubs.usgs.gov/of/2013/1165/pdf/ofr2013-1165_appendixO.pdf (Quigley et al., 2012)
M. Quigley, R. Van Dissen, N. Litchfield, P. Villamor, B. Duffy, D. Barrell, K.
Furlong, T. Stahl, E. Bilderback and D. Noble, Surface rupture during the 2010 Mw 7.1 Darfield (Canterbury) earthquake: Implications for fault rupture dynamics and seismic-hazard analysis, Geology, January 2012, v. 40, p. 55-58 (First published on November 23, 2011)
15
(Schwartz and Coppersmith, 1984)
Schwartz, D. P., and K. J. Coppersmith (1984), Fault behavior and characteristic earthquakes - examples from the Wasatch and San Andreas fault zones, J. Geophys. Res.,
89, 5681-5698.
(Simpson et al., 2006)
R. W. Simpson, M. Barall, J. Langbein, J. R. Murray, and M. J. Rymer, San Andreas Fault Geometry in the Parkfield, California Region, Bulletin of the Seismological Society of America, September 2006, v. 96, p. S28-S37,doi:10.1785/0120050824 (Spudich, 1996)
Paul Spudich, editor, The Loma Prieta, California, Earthquake of October 17, 1989 Main Shock Characteristics, U.S. Geological Survey Professional Paper 1550-A 1996 (Stein et al., 2011)
Seth Stein, Robert Geller, and Mian Liu, Bad Assumptions or Bad Luck: Why Earthquake Hazard Maps Need Objective Testing, Seismological Research Letters, September/October 2011, v. 82, p. 623-626,doi:10.1785/gssrl.82.5.623 (Thurber et al., 2006)
Clifford Thurber, Haijiang Zhang, Felix Waldhauser, Jeanne Hardebeck, Andrew Michael, and Donna Eberhart-Phillips, Three-Dimensional Compressional Wavespeed Model, Earthquake Relocations, and Focal Mechanisms for the Parkfield, California, Region, Bulletin of the Seismological Society of America, September 2006, v. 96,
- p. S38-S49,doi:10.1785/0120050825 (Wesnousky, 1994)
Wesnousky, S. G. (1994), The Gutenberg-Richter or characteristic earthquake distribution, which is it?, Bull. Seismol. Soc. Am., 84, 1940-1959.
- 6.
A genuine dispute exists with the applicant on a material issue of law or fact As set forth in the contention and its basis statement, this contention raises a genuine dispute with the applicant regarding the adequacy of PG&Es SAMA Analysis to support the proposed renewal of PG&Es operating license for Diablo Canyon.
16
CONTENTION D. Inadequate Discussion of Flooding Risks in SAMA Analysis
- 1.
Statement of Contention PG&Es SAMA Analysis (Appendix F of PG&Es Amended ER) is inadequate to satisfy NEPA or NRC implementing regulation 10 C.F.R. § 51.53(c)(3)(ii)(L) because PG&Es evaluation of potential severe accident mitigation measures is not based on a sufficiently rigorous or up-to-date analysis of flooding risks. As a result, PG&Es evaluation of the comparative costs and benefits of measures to prevent or mitigate the effects of a severe earthquake does not sufficiently credit the cost-effectiveness of mitigation measures. In particular, PG&E failed to consider information about the risk of flooding of DCNPP safety equipment caused by local intense precipitation (LIP) flooding events, as presented in PG&Es post-Fukushima flooding analysis. Letter from Barry Allen, PG&E, to NRC, re: Final Response to Request for Information Pursuant to 10 CFR 50.54(f) Regarding Recommendation 2.1 Flooding (March 11, 2015), Enclosure 1: Diablo Canyon Power Plant Units 1 and 2 Flood Hazard Reevaluation Report In Response to 50.54 Information Request Regarding Near-Term Task Force Recommendation 2.1 (Flood Hazard Reevaluation Report).
- 2.
Statement of Basis for the Contention
- a.
NEPA requirements See Contention C Section 2.a above for a discussion of NEPA requirements that are relevant to this contention.
- b.
Failure to consider relevant information in Flood Hazard Reevaluation Report The Flood Hazard Reevaluation Report provides PG&Es response to the U.S. Nuclear Regulatory Commissions (NRC) March 12, 2012 request for information pursuant to the post-Fukushima Near-Term Task Force (NTTF) Recommendation 2.1 flooding hazards reevaluation
17
of Diablo Canyon Power Plant (DCPP). Id. at 1-1. The Flood Hazard Reevaluation Report assesses a set of flooding risk mechanisms at DCNPP in light of currently available information, including the risk of LIP flooding events, storm surges, seiches, tsunamis, and wind-generated waves. Id. at 1 1-3.
For most of these flooding risks, PG&E concluded that the hazard did not apply to DNCPP, would not affect DCNPP safety equipment, or was bounded by the DCNPP design basis. Id., Chapter 5. With respect to LIP flooding events, however, PG&E concluded that LIP will result in positive water depth at doors and areas adjacent to safety and non safety-related structures. Id. at 5-1. PG&E also stated that it would perform an integrated assessment for the beyond design basis LIP event in accordance with NRC-approved guidance and that the integrated assessment would address [l]ong-term mitigation actions. Id. In the meantime, PG&E identified short-term mitigation measures that could be used to protect safety equipment, such as utilizing existing weather forecasting technologies combined with deployment of temporary barriers (sandbags or equivalent) at affected doors and safety and non-safety structures. Id.
Although PG&E has identified LIP flooding events as posing a reasonably foreseeable risk to DCNPP safety equipment, PG&Es SAMA Analysis contains no information about the risk of LIP flooding events, nor does it identify mitigation measures for LIP flooding events. In order to comply with NEPA and NRC implementing regulations, PG&Es SAMA Analysis must address the relevant information provided in the Flood Hazard Reevaluation Report about the risk of LIP flooding events, as well as mitigation measures for the license renewal term. Duke Energy Corp., 56 NRC at 8; Pacific Gas and Electric Co., 74 NRC at 443 (SAMA Analysis must consider relevant information from outside sources); 10 C.F.R. §§ 51.53(c)(iv), 51.92(a)(2)
18
(Environmental Reports and EISs must address new and significant information that was not previously addressed.) The short-term mitigation measures set forth in the Flood Hazard Reevaluation Report would not suffice for this purpose, because they are interim measures that are not intended to cover an entire license renewal term.
- 3.
Demonstration that the contention is within the scope of the proceeding This contention is within the scope of the Diablo Canyon license renewal proceeding because it challenges the adequacy of the SAMA Analysis for Diablo Canyon to satisfy NEPA and NRC implementing regulations.
- 4.
Demonstration that the contention is material to the findings the NRC must make to re-license Diablo Canyon The contention is material to the findings that the NRC must make in order to license this reactor because it challenges the environmental analysis that the NRC will rely on for its NEPA findings in the DCNPP license renewal proceeding.
- 5.
Concise statement of the facts or expert opinion supporting the contention, along with appropriate citations to supporting scientific or factual materials The facts on which SLOMFP relies are presented in PG&Es own documents and are summarized above in Section 2 (basis statement).
- 6.
A genuine dispute exists with the applicant on a material issue of law or fact This contention raises a genuine dispute with the applicant regarding the adequacy of PG&Es SAMA Analysis to support the proposed renewal of PG&Es operating license for Diablo Canyon, because SLOMFP challenges PG&Es failure to include relevant information in the SAMA Analysis.
19
III.
THE CONTENTIONS ARE TIMELY PURSUANT TO 10 C.F.R. §§ 2.309(c) and 2.309(f)(2)
NRC regulations 10 C.F.R. § 2.309(c) and § 2.309(f)(2) call for a showing that:
(i) The information upon which the amended or new contention is based was not previously available; (ii) The information upon which the amended or new contention is based is materially different than information previously available; and (iii) The amended or new contention has been submitted in a timely fashion based on the availability of the subsequent information.
This motion satisfies all three of these standards for filing a contention after the initial filing deadline. First, the information upon which the new contentions are based was not previously available, because PG&E did not submit it until recently. The information is contained in PG&Es March 2015 responses to the NRCs March 12, 2012 Request for Additional Information Regarding Near-Term Task Force Recommendation 2.1 (the SHS Report and Flood Hazard Reevaluation Report).
Second, the reports regarding seismic and flooding risks submitted by PG&E in March 2015 contain information that is materially different from previously submitted information. As requested by the NRC in its Request for Additional Information, PG&E itself purports to present and evaluate the most recent and most comprehensive information available in these reports.
Finally, SLOMFPs contentions are timely, because they are being submitted within 30 days of March 16, 2015, when SLOMFP received from PG&Es counsel the SHS Report and the Flood Hazard Reevaluation Report.
IV.
CERTIFICATE REGARDING CONSULTATION Pursuant to 10 C.F.R. § 2.323(b) undersigned counsel for SLOMFP certifies that on April 14, 2015, she contacted counsel for PG&E and the NRC Staff to seek their consent to the filing
20
of SLOMFPs motion and contentions. Counsel for PG&E stated that PG&E takes no position on the admissibility of SLOMFPs proposed contentions, and will respond to them in due course.
Counsel for the NRC Staff stated that the NRC staff will not object to the filing of the motion, but reserves the right to raise all applicable objections at the appropriate time.
V.
CONCLUSION For the foregoing reasons, the ASLB should admit SLOMFPs contentions C and D.
Respectfully submitted,
[Electronically signed by]
Diane Curran Harmon, Curran, Spielberg & Eisenberg, L.L.P.
1726 M Street N.W. Suite 600 Washington, D.C. 20036 202-328-3500 Fax: 202-328-6918 E-mail: dcurran@harmoncurran.com Counsel to SLOMFP April 15, 2015
April 15, 2015 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the matter of Pacific Gas and Electric Company Docket Nos. 50-275-LR Diablo Canyon Nuclear Power Plant 50-323-LR Units 1 and 2 DECLARATION OF DR. DAVID D. JACKSON IN SUPPORT OF SAN LUIS OBISPO MOTHERS FOR PEACES MOTION TO FILE NEW CONTENTION REGARDING ADEQUACY OF SEVERE ACCIDENT MITIGATION ALTERNATIVES ANALYSIS FOR DIABLO CANYON LICENSE RENEWAL APPLICATION Under penalty of perjury, I, David D. Jackson, declare as follows:
- 1. My name is David D. Jackson. I am a Professor of Geophysics, Emeritus, at the University of California at Los Angeles (UCLA). I am qualified by training and experience as an expert in the fields of geophysics and seismology. A copy of my curriculum vitae is attached.
- 2. I have a Ph.D. in Geophysics from the Massachusetts Institute of Technology (1969) and a B.S. in Physics from the California Institute Technology (1965). For over 45 years, I have been a Professor of Geophysics at UCLA. I have written many academic papers on earthquake seismology of California and have served been a member or officer of many professional organizations relevant to my expertise, including the American Geophysical Union, the International Union of Geodynamics and Geophysics, and the National Academy of Sciences/Natural Resource Council Panel on Earthquake Science. I have served as Science Director of the Southern California Earthquake Center and was a member of the National Earthquake Prediction Evaluation Council and the California Earthquake
2 Prediction Evaluation Council. I have been a member of the Working Group on California Earthquake Probabilities since 2009.
- 4. The purpose of this declaration is to support a contention by the San Luis Obispo Mothers for Peace (SLOMFP) challenging the adequacy of Pacific Gas & Electric Co.s (PG&Es) seismic risk analysis for the Severe Accident Mitigation Alternatives (SAMA)
Analysis in PG&Es Amended Environmental Report (2015) for the proposed re-licensing of Diablo Canyon nuclear power plant. The contention is entitled Inadequate Consideration of Seismic Risk in SAMA Analysis.
- 5.
I am familiar with seismic risk aspects of PG&Es SAMA Analysis; PG&Es Seismic Hazard and Screening Report for Diablo Canyon Power Plant Units 1 and 2 (March 2015);
and PG&Es Seismic Source Characterization for the Diablo Canyon Power Plant, San Luis Obispo County, California; report on the results of a SSHAC level 3 study (Rev. A, March 2015). I am also familiar with the scientific literature regarding the seismology of California, including the Uniform California Earthquake Rupture Forecast, Version 3 (UCERF3).
- 6. The factual statements in SLOMFPs Contention C (Inadequate Consideration of Seismic Risk in SAMA Analysis), par. 2 (Statement of Basis) are true and correct to the best of my knowledge, and the conclusions therein are based on my best professional judgment.
DAVID D. JACKSON Department of Earth and Space Sciences, UCLA Los Angeles, CA 90095-1567 April 15, 2015 Professional Preparation:
! B.S., Department of Physics, California Institute of Technology,1965
! Ph.D, Department of Earth and Planetary Science, MIT, 1969 Appointments:
! Distinguished Professor of Geophysics, Emeritus, UCLA 2011 - present
! Professor of Geophysics, UCLA 1969 - 2011 Awards and Honors:
! National Academy of Sciences/Natural Research Council, Senior Resident Research Associateship, 1981-1982
! Elected to Steering Committee, University NAVSTAR Consortium (UNAVCO) 1987, 1988, 1989, 1990, 1991, 1992.
! Elected Secretary, Seismology Section, American Geophysical Union, 1989.
! Elected President, Seismology Section, American Geophysical Union 1991.
! Fellow, American Geophysical Union 1993.
! Elected Chair, US National Committee for the International Union of Geodesy and Geophysics (IUGG).
1999-2003.
! Elected Secretary, USNC/IUGG 2003-2007.
! Elected to Finance Committee, IUGG 2003-2007.
! Appointed Chair, Dept. Earth and Space Sciences, UCLA 2004-2007.
! Elected to Bureau of IUGG, 2007 - 2011.
Service:
! California Earthquake Prediction Evaluation Council, Office of Emergency Services, State of California 1984-2002.
! Committee on Seismology, National Academy of Sciences, National Research Council.
! Panel on Crustal Movement Measurements, Committee on Geology, National Academy of Sciences/National Research Council (NAS/NRC).
! Panel on Science of Earthquakes, NAS/NRC 1996-2003,
! Chair, Committee on Public Affairs, American Geophysical Union 1996-1998,
! Science Director, Southern California Earthquake Center 1996-1999.
! U. S. National Committee for IUGG 1995-2007.
! National Earthquake Prediction Evaluation Council, 2007 - 2014.
! Appointed Internation Association for Seismology and Physics of the Earths Interior (IAPEI) Liaison to Georisk Commission, 2007-2015
David D. Jackson April 15, 2015 Published articles since 2010 Strader, A., & Jackson, D. D. (2015). Static Coulomb stressbased Southern California earthquake forecasts: A pseudoprospective test. Journal of Geophysical Research: Solid Earth.
Field, E. H., Biasi, G. P., Bird, P., Dawson, T. E., Felzer, K. R., Jackson, D. D.,... & Zeng, Y.
(2015). LongTerm TimeDependent Probabilities for the Third Uniform California Earthquake Rupture Forecast (UCERF3). Bulletin of the Seismological Society of America, 105(2A), 511-543.
Field, E. H., Arrowsmith, R. J., Biasi, G. P., Bird, P., Dawson, T. E., Felzer, K. R.,... & Zeng, Y.
(2014). Uniform California Earthquake Rupture Forecast, Version 3 (UCERF3)The Time Independent Model. Bulletin of the Seismological Society of America, 104(3), 1122-1180.
Rong, Y., Jackson, D. D., Magistrale, H., & Goldfinger, C. (2014). Magnitude limits of subduction zone earthquakes. Bulletin of the Seismological Society of America, 104(5), 2359-2377.
Kagan, Y. Y., & Jackson, D. D. (2014). Statistical earthquake focal mechanism forecasts. Geophysical Journal International, ggu015.
Kagan, Y. Y., & Jackson, D. D. (2013). Tohoku earthquake: a surprise?. Bulletin of the Seismological Society of America, 103(2B), 1181-1194.
Hiemer, S., Jackson, D. D., Wang, Q., Kagan, Y. Y., Woessner, J., Zechar, J. D., & Wiemer, S.
(2013). A stochastic forecast of California earthquakes based on fault slip and smoothed seismicity. Bulletin of the Seismological Society of America, 103(2A), 799-810.
Kagan, Y. Y., & Jackson, D. D. (2012). Whole Earth high-resolution earthquake forecasts. Geophysical Journal International, 190(1), 677-686.
Kagan, Y. Y., Jackson, D. D., & Geller, R. J. (2012). Characteristic earthquake model, 1884-2011, RIP. Seismological Research Letters, 83(6), 951-953.
Chu, A., Schoenberg, F. P., Bird, P., Jackson, D. D., & Kagan, Y. Y. (2011). Comparison of ETAS parameter estimates across different global tectonic zones. Bulletin of the Seismological Society of America, 101(5), 2323-2339.
Werner, M. J., Helmstetter, A., Jackson, D. D., & Kagan, Y. Y. (2011). High-resolution long-term and short-term earthquake forecasts for California. Bulletin of the Seismological Society of America, 101(4), 1630-1648.
Wang, Q., Jackson, D. D., & Kagan, Y. Y. (2011). California earthquake forecasts based on smoothed seismicity: Model choices. Bulletin of the Seismological Society of America, 101(3),
1422-1430.
Jackson, D. D., & Kagan, Y. Y. (2011). Characteristic earthquakes and seismic gaps. Encyclopedia of Solid Earth Geophysics, 37-40.
Kagan, Y. Y., & Jackson, D. D. (2011). Global earthquake forecasts.Geophysical Journal International, 184(2), 759-776.
Wang, Q., Jackson, D. D., & Zhuang, J. (2010). Missing links in earthquake clustering models. Geophysical Research Letters, 37(21).
Kagan, Y. Y., Bird, P., & Jackson, D. D. (2010). Earthquake patterns in diverse tectonic zones of the globe. Pure and applied geophysics, 167(6-7), 721-741.
Schorlemmer, D., Zechar, J. D., Werner, M. J., Field, E. H., Jackson, D. D., Jordan, T. H., &
RELM Working Group. (2010). First results of the regional earthquake likelihood models experiment. Pure and Applied Geophysics, 167(8-9), 859-876.
Kagan, Y. Y., & Jackson, D. D. (2010). Earthquake forecasting in diverse tectonic zones of the globe. Pure and applied geophysics, 167(6-7), 709-719.
David D. Jackson Selected Reviewed Publications August 19, 2010 Chu, A., F.P. Schoenberg,, P. Bird, D.D. Jackson, and Y.Y. Kagan Y., Comparison of ETAS parameter estimates across different global tectonic zones, Bulletin of the Seismological Society of America, submitted, (2010)
Werner, M. J., A. Helmstetter, D.D. Jackson, Y. Y. Kagan, and S.Wiemer (2010b), Adaptively smoothed seismicity earthquake forecasts for Italy, Annals of Geophysics, in press; preprint available at http://arxiv.org/abs/1003.4374 (2010).
Wang Q, and D.D. Jackson. Missing links in earthquake clustering models, Seis. Res. Lett., submitted, (2010)
Wang Q, D.D. Jackson, and Y. Y. Kagan. Five-and ten-year California earthquake forecasts based on smoothed seismicity, Bulletin of the Seismological Society of America, in press, (2010)
Wang Q, F. Schoenberg, and D.D. Jackson. Standard errors of parameter estimates in the ETAS model.
Bulletin of the Seismological Society of America in press, (2010)
Wang Q, D.D. Jackson, and J. Zhuang. Are spontaneous earthquakes stationary in California? Journal of Geophysical Research, in press, (2010)
M.J. Werner, A. Helmstetter, D.D. Jackson, and Y.Y. Kagan. High Resolution Long-and Short-Term Earthquake Forecasts for California, Bull. Seismol. Soc. Amer., in press. (2010)
Console,R., D.D.Jackson andY.Y.Kagan.Using the ETAS model for catalog declustering and seismic background assessment, Pure Appl.Geoph.(The FrankEvisonVolume),167(6/7),819-830,doi:10.1007/s00024-010-0065-5 (2010).
Y.Y. Kagan, P. Bird, and D.D. Jackson, Earthquake patterns in diverse tectonic zones of the globe, Pure Appl. Geoph. (The Frank Evison Volume). 167(6/7) 721-741. doi:10.1007/s00024-010-0075-3, (2010)
Y.Y. Kagan, P. Bird, and D.D. Jackson, Earthquake forecasting in diverse tectonic zones of the globe, Pure Appl. Geoph.(The Frank Evison Volume). 167(6/7) 709-719. doi:10.1007/s00024-010-0074-4, (2010).
Y.Y. Kagan and D.D. Jackson, Short-and long-term earthquake forecasts for California and Nevada, Pure Appl. Geoph. (The Frank Evison Volume). 167(6/7) 685-692, doi:10.1007/s00024-010-0073-5, (2010)
Bird, P., Y.Y. Kagan, D.D. Jackson, F.P. Schoenberg, and M.J. Werner,. Linear and nonlinear relations between relative plate velocity and seismicity, Bull. Seismol. Soc. Amer., 99 (6), 3097-3113, (plus electronic supplement). (2009).
Qi Wang, D.D. Jackson, and Y.Y. Kagan, California Earthquakes, 1800-2007: A Unified Catalog with Moment Magnitudes, Uncertainties, and Focal Mechanisms, Seismological Research Letters 80: 446-457. (2009)
J.-C. Zhuang, A. Christophersen,; M.K. Savage, D. Vere-Jones, Y. Ogata, and D.D. Jackson, Differences between spontaneous and triggered earthquakes: their influences on foreshock probabilities J. Geophys. Res., 113 (B11), (2008)
N.M. Black and D.D. Jackson, Probability of Multifault Rupture, Bulletin of the Seismological Society of America, 98: 3017 - 3024. (2008)
Z.K. Shen, D.D. Jackson, and Y.Y. Kagan, Implications of geodetic strain rate for future earthquakes, with a five-year forecast of M5 earthquakes in southern California, Seis. Res. Lett., 78(1), 116-120, (2007).
Y. Y. Kagan, D.D. Jackson, and Y. Rong, A testable five-year forecast of moderate and large earthquakes in southern California based on smoothed seismicity, Seis. Res. Lett., 78(1), 94-98, (2007).
A. Helmstetter, Y. Y. Kagan, and D.D. Jackson, High-resolution time-independent grid-based forecast
David D. Jackson Selected Reviewed Publications August 19, 2010 for M>5 earthquakes in California, Seis. Res. Lett., 78(1), 78-86 ( 2007).
D. Schorlemmer, M.C. Gerstenberger, S. Wiemer, D.D. Jackson, and D. A. Rhoades,. Earthquake likelihood model testing, Seis. Res. Lett., 78(1), 17-29 ( 2007).
Y. Y. Kagan,., D.D. Jackson, and Y. F. Rong, A new catalog of southern California earthquakes, 1800-2005, Seismological Research Letters, 77(1), 30-38., (2006).
D.D. Jackson and Y. Y. Kagan, The 2004 Parkfield Earthquake, the 1985 Prediction, and Characteristic Earthquakes: Lessons for the Future, Bulletin of the Seismological Society of America, 96: S397 - S409, (2006)
A. Helmstetter, Y. Y. Kagan, and D.D. Jackson,. Comparison of short-term and time-independent earthquake forecast models for southern California, Bull. Seismol. Soc. Amer., 76(1),90-106, (2006).
Y.Y. Kagan and D.D. Jackson, Comment on `Testing earthquake prediction methods: "The West Pacific short-term forecast of earthquakes with magnitude MwHRV >= 5.8"' by V. G.
Kossobokov,Tectonophysics, 413, iss. 1-2 [SPECIAL ISSUE], pp. 33-48. (2006).
A. Helmstetter., Y. Y. Kagan, and D.D. Jackson. Importance of small earthquakes for stress transfers and earthquake triggering, J. Geophys. Res., 110(5), pp. 1-13, B05S08, doi:10.1029/2004JB003286,.(2005)
Y.Y. Kagan, D.D. Jackson, and Z. Liu. Stress and earthquakes in southern California, 1850-2004, J.
Geophys. Res.,110(5), B05S14, pp. 1-13, doi:10.1029/2004JB003313,. (2005).
D. Schorlemmer, S. Wiemer, M. Wyss, and D.D. Jackson, Earthquake statistics at Parkfield: 2.
Probabilistic forecasting and testing, J. Geophys. Res. Solid Earth 109 (B12): Art. No. B12308 (2004).
D.D. Jackson: Earthquake prediction and forecasting in State of the planet: frontiers and challenges, Project of the International Union of Geodesy and Geophysics (2004).
D.D. Jackson and U.S. committee on The Science of Earthquakes, et al: Living on an active Earth -
Perspectives on earthquakes science, National Research Council of the National Academies Press, p.1-418 (2003)
Y. Rong, D.D. Jackson and Y.Y. Kagan: Probabilistic forecasting of seismicty, in Earthquake science and seismic risk reduction. editors: Francesco Mulargia and Robert J..Geller, Earth and Environmental Sciences, v.32, (2003)
Y. Rong, D.D. Jackson, and Y.Y. Kagan: Seismic gaps and earthquakes, J. of Geophys. Res., v.108, no.B10, p.6-1 thru 6-14, 2471, doi:10.1029/2002JB-002334 (2003) 15 pages P. Bird, Y.Y. Kagan, and D.D. Jackson: Plate tectonics and earthquake potential of spreading ridges and oceanic transform faults, in Plate Boundary Zones, editors: Seth Stein and Jeffrey T.
Freymueller, AGU, Geodynamics Series, v.30, Chapter 14, p. 203-218 (2002) 16 pages D.D. Jackson and P. Patrick Leahy: Introduction to the special issue on the sustainability of Earth resources - The role of the geosciences in the evolution toward a globally sustainable society, Intern.
Geology Rev., v.11, no.12, p.1069-1071 (2002) 3 pages Y.-F. Rong, D.D. Jackson: Earthquake potential in and around China: Estimated from past earthquakes, Geophys. Res. Ltrs, v.29, Issue 16, p.27-1 to 27-4, CiteID 1780, DOI 10.1029/2002GL015297 (2002) 4 pages Z.-K.Shen, M. Wang, Y. Li, D.D. Jackson, A. Yin, D. Dong, and P. Fang: Crustal deformation along the Altyn Tagh fault system, western China, from GPS. J. Geophys. Res., v.106, p.30607-30621, 15 pages (2001)
Z.K. Shen, C. K. Zhao, A. Yin, Y. Li, D.D. Jackson, P. Fang, and D. Dong: Contemporary crustal deformation in East Asia constrained by Global Positioning System measurements, J. Geophys. Res.,
v.105, p.5721-5734, 14 pages (2000).
M. Hashimoto, S. Miyazaki, D.D. Jackson: A block-fault model for defor-mation of the Japanese Islands derived from continuous GPS observation, Earth Planets Space, v.52 (11): 1095-1100 (2000)
Y.Y. Kagan, and D.D. Jackson: Probabilistic forecasting of earthquakes, Geophys. J. Int., v.143,
David D. Jackson Selected Reviewed Publications August 19, 2010 p.438-453, 16 pages (2000).
E.H. Field, J. G. Anderson, T. L. Henyey, D.D. Jackson, W. B. Joyner, Y. Lee, H, Magistrale, B.
Minster, K. B. Olsen, J. H. Steidl, L. A. Wald, and C. J. Wills: Accounting for site effects in probabilistic seismic hazard analyses of southern California: Overview of the SCEC Phase III Report, Bull. Seis. Soc. Amer, v.90, p.S1 - S31 32 pages (2000)
Y.Y. Kagan, and D.D. Jackson: Worldwide doublets of large shallow earthquakes, Bull. Seis. Soc.
Amer. v.85, no.9, (1999)
D.D. Jackson and Y.Y. Kagan: Testable earthquake forecasts for 1999, Seis. Res. Letters, v.70, no.4,
- p. 393-403, 11 pages (1999)
Field, E. H., D.D. Jackson, and J. F. Dolan, A mutually consistent seismic-hazard source model for southern California, Bull. Seis. Soc. Amer., v. 89, no. 3, p. 559, 19 pages (1999)
Kagan, Y.Y., and D.D. Jackson, Spatial aftershock distribution: Effect of normal stress, J. Geophys.
Res., v. 103, page 24,453, 14 pages, (1998)
D.D. Jackson: "The Case for Huge Earthquakes", Seis.Res. Letts., v.67, no.1, p.3-5, 3 pages (originally published in English-1996) *Translated in to Japanese Chishitsu News (1998).
Y. Bock, S. Wdowinski, P. Fang, J. Zhang, S. Williams, H. Johnson, J. Behr, J. Genrich, J. Dean, M. can Domselaar, D. Agnew, F. Wyatt, K. Stak, B. Oral, K. Hudnut, R. King, T. Herring, S. Dinardo, W.
Young, D.D. Jackson, W. Burtner: "Southern California Permanent GPS Geodetic Array; Continuous Measurements of Regional Crustal Deformation Between the 1992 Landers and 1994 Northridge Earthquakes", J. Geophys. Res. - Solid Earth, v.102, no.B8, p.18,013-18,033, 21 pages (1997)
D.D. Jackson, Z.-K. Shen, D. Potter, X.-B. Ge; L. Y. Sung: "Southern Calif-ornia Deformation",
Science, v.275, no.N5332, p.1621-1622, 2 pages (1997)
R.J. Geller, D.D. Jackson, Y.Y. Kagan, F. Mulargia: "Geoscience - Earth-quakes Cannot be Predicted",
Science, v.275, no.N5306, p.1616-1617, 2 pages (1997)
Z.-K. Shen, D.D. Jackson, B.-X. Ge: "Crustal Deformation Across and Beyond the Los Angeles Basin from Geodetic Measurements", J. Geophys. Res. - Solid Earth, v.101, no.NB12, p.27957-27980, 23 pages (1996)
A. Gabrielov, Vladimir Keilis-Borok and David D. Jackson: "Geometric Incompatibility in a Fault System", Prod. Natl. Acad. Sci. USA, v.93, p.3838-3842, 5 pages (1996)
David D. Jackson: "Hypothesis Testing and Earthquake Prediction", Proc. Natl. Acad. Sci., v.93, p.3772-3775, 3 pages (1996)
Richard A. Snay, M.W. Cline, C.R. Philipp, D.D. Jackson, Y. Feng, Z.-K. Shen and M.Lisowski:
"Crustal Velocity Field Near the Big Bend of California's San Andreas Fault", J. Geophys. Res., v.101, p.3173-3185, 12 pages (1996)
David D. Jackson: "Earthquake Prediction Evaluation Standards Applied to the VAN Method",
Geophys. Res. Lett., v.23, p.1363-1370, 7 pages (1996)
Z.-K. Shen, B.X. Ge, D.D. Jackson, D. Potter, M. Cline and L.Y. Sung: "Northridge Earthquake Rupture Models Based on the Global Positioning System Measurements", Bull. Seis. Soc. Amer., v.86, p.S37-S48, 11 pages (1996)
D.D. Jackson: "The Case for Huge Earthquakes", Seis.Res. Letts., v.67, no.1, p.3-5, 3 pages (1996)
D.D. Jackson, K. Aki, C.A. Cornell, J.H. Dieterich, T.L. Henyey, M. Mahdyiar, D. Schwartz, S.N.
Ward: "Seismic Hazards in Southern California: Probable Earthquakes", Bull. Seis. Soc. Amer., v.85, p.379-439, 60 pages (1995)
Y.Y. Kagan and D.D. Jackson: "New Seismic Gap Hypothesis: Five Years After ", J. Geophys. Res.,
v.100, p.3943-3960, 17 pages (1995)
Y.Y. Kagan and D.D. Jackson: "Long-Term Probabilistic Forecasting of Earthquakes", J. Geophys.
Res., v.99, p.13685-13700, 15 pages (1994)
D.D. Jackson, K. Aki, T. Henyey, C.A. Cornell, J. Dieterich, M. Madhyiar, D. Schwartz and S. Ward:
"Seismic Hazards in Southern California: Probable Earthquakes, 1991-2004", &D&@&Din&@
David D. Jackson Selected Reviewed Publications August 19, 2010 Proceedings of the 9'th Joint Meeting of the United States-Japan National Resources Panel on Earthquake Prediction Technology, v.9, p.333-391, 59 pages (1994)
Z.-K. Shen, D.D. Jackson, Y. Feng and Y. Bock : "Postseismic Deformation Following the Landers Earthquake, California, 28 June 1992", Bull. Seis. Soc. Amer., v.84, p.780-791, 12 pages (1994)
K.L. Feigl, D.C. Agnew, Y. Bock, D. Dong, A. Donnellan, B.H. Hager, T.A. Herring, D.D. Jackson, R.H. Jordan, R.W. King, S. Larsen, K.M. Larson, M. Murray, Z.-K. Shen and F.H. Webb: "Space Geodetic Measurement of Crustal Deformation in Central and Southern California", J. Geophys. Res.,
v.98, p.21,677-21,712, 36 pages (1993)
M. Hashimoto and D.D. Jackson: "Plate Tectonics and Crustal Deformation Around the Japanese Islands", J. Geophys. Res., v.98, p.16,149-16,166, 18 pages (1993)
Z.-K. Shen and D.D. Jackson: "Global Positioning System Reoccupation of Early Triangulation Sites:
Tectonic Deformation of the Southern Coast Ranges", J. Geophys. Res., v.98, p.9931-9946, 19 pages (1993)
S.P. Nishenko, L.R. Sykes, D.D. Jackson and Y. Kagan: "Seismic Gap Hypothesis: Ten Years After",
J. Geophys. Res., v.98, p.9909-9920, 12 pages (1993)
Working Group on the Probabilities of Future Large Earthquakes in Southern California: "Future Seismic Hazards in Southern California", Phase I-Implications of the 1992 Landers Earthquake Sequence, 42 pages (1992)
Y.Y. Kagan and D.D. Jackson: "Seismic Gap Hypothesis: Ten Years After", J. Geophys. Res., v.96, p.21,419-21,429, 11 pages (1991)
Y.Y. Kagan and D.D. Jackson: "Long-Term Earthquake Clustering", Geophys, J. Int., v.104, p.117-133, 17 pages (1991)
P.M. Davis, D.D.Jackson and Y.Y. Kagan: "The Longer It Has Been Since the Last Earthquake, The Longer the Expected Time Till the Next?", Bull. Seis. Soc. Amer., v.79, p.1439-1456, 18 pages (1989)
S-B. Yu, D.D. Jackson, G-K. Yu and C-C Liu: "Dislocation Model for Crustal Deformation in the Longitudinal Valley Area, Eastern Taiwan", Tectonophysics, v.183, p.97, 13 pages (1990)
D. Agnew, Y. Bock, B.Hager, D. Jackson, T. Jordan and R. King: "GPS Measurements in Central and Southern California", CSTG Bulletin #10, GPS Projects for Geodesy and Geodynamics, International Coordination of Space Techniques for Geodesy and Geodynamics, Committee on Space Techniques in Geodesy, International Association of Geodesy, Int. Union Geodesy and Geophysics, p.71, 16 pages (1988)
C. Macdonald, P.M. Davis and D.D. Jackson: "Inversion of Reflection Travel Times and Amplitudes",
Geophysics, v.52:5, p.606, 11 pages (1987)
A. Cheng, D.D. Jackson and M. Matsu'ura: "Aseismic Crustal Deformation in the Transverse Ranges of Southern California", Tectonophysics, v.144, p.159, 21 pages (1987)
C. Macdonald, P.M. Davis and D.D. Jackson: "Inversion of Reflection Data", Seismic Acoustics Laboratory Annual Progress Review, v.17, p.165, 36 pages (1986)
M. Matsu'ura, D.D. Jackson and A. Cheng: "Dislocation Model for Aseismic Crustal Deformation at Hollister, California", J. Geophys. Res., v.91:B12, p.12661, 14 pages (1986)
D.D. Jackson and M. Matsu'ura: "A Bayesian Approach to Nonlinear Inversion", J. Geophys. Res.,
v.90, p.581, 11 pages (1985)
D.D. Jackson, A. Cheng and C-C. Liu: "Tectonic Motions and Systematic Errors in Leveling and Trilateration Data for California", Tectonophysics, v.97, p.73, 11 pages (1983)
R.A. Ergas and D.D. Jackson: "Spatial Variation of Crustal Seismic Velocities in Southern California",
Bull. Seis. Soc. Amer., v.71:3, p.671, 19 pages (1981)
D.D. Jackson, W.B. Lee and C-C. Liu: "Height Dependent Errors in Southern California Leveling",
Earthquake Prediction--An International Review Maurice Ewing Series 4 &D[American Geophysical U.,
p.457, 16 pages (1981)
D.D. Jackson: "3. Measurements of Deformation near Active Plate Boundaries", Geodetic Monitoring
David D. Jackson Selected Reviewed Publications August 19, 2010 of Tectonic Deformation--Toward a Strategy &D[Panel on Crustal Movement Measurements/Comm. on Geodesy-Seism., Assemb. Math. Phys. Sci: NRC, Washington, D.C., p.25, 25 pages (1981)
D.D. Jackson, W.B. Lee and C.C. Liu: "Aseismic Uplift in Southern California: An Alternate Interpretation", Science, v.210, p.534, 3 pages (1981)
D.D. Jackson: "The Use of A Priori Data to Resolve Non-Uniqueness in Linear Inversion", Geophys. J.
Royal Astron. Soc., v.57, p.137, 21 pages (1979)
D.D. Jackson: "Linear Inverse Theory with A Priori Data", Lecture Notes in Physics, 85, Applied Inverse Problems&D, ed: P.C. Sabatier [Spring-Verlag, New York p.83, 20 pages (1978)
K.A. Poehls and D.D. Jackson: "Tectonomagnetic Event Detection using Empirical Transfer Functions", J. Geophys. Res., v.83:B10, p.4933, 8 pages (1978)
J.B. Rundle and D.D. Jackson: "Numerical Simulation of Earthquake Sequences", Bull. Seis. Soc.
Amer., v.67:5, p.1363, 15 pages (1977)
J.B. Rundle and D.D. Jackson: "A Kinematic Viscoelastic Model of the San Francisco Earthquake of 1906", Geophys. J. Royal Astron. Soc., v.50, p.441, 18 pages (1977)
J.B. Rundle and D.D. Jackson: "A Three-Dimensional Viscoelastic Model of a Strike Slip Fault",
Geophys. J. Royal Astron. Soc., v.49, p.575, 17 pages (1977)
N. Burkhard and D.D. Jackson: "Application of Stabilized Linear Inverse Theory to Gravity Data", J.
Geophys. Res., v.81:8, p.1513, 6 pages (1976)
D.D. Jackson: "Most Squares Inversion", J. Geophys. Res., v.81:5, p.1027, 4 pages (1975)
D.T. Griggs, D.D. Jackson, L. Knopoff and R.L. Shreve: "Earthquake Prediction: Modeling the Anomalous Vp/Vs Source Region", Science, v.187, p.537, 4 pages (1975)
D.D. Jackson: "Marginal Solutions to Quasi-Linear Inverse Problems in Geophysics: The Edgehog Method", Geophys. J. R. Astron. Soc., v.35, p.121, 16 pages (1973)
L. Knopoff, R. Mitchel and D.D. Jackson: "A Stochastic Analysis of a Model Earthquake Sequence",
Geophys. J. R. Astron. Soc., v.29, p.255, 7 pages (1972 )
- l. Knopoff and D.D. Jackson: "The Analysis of Underdetermined and Overdetermined Systems",
Dynamic Response of Structures, G. Hermann and N. Peronne (eds.), Pergamon Press, p.289, 17 pages (1972)
D.D. Jackson: "Interpretation of Inaccurate, Insufficient and Inconsistent Data", Geophys. J. R. Astron.
Soc., v.28, p.97, 13 pages (1972)
D.D. Jackson: "Attentuation of Seismic Waves by Grain Boundary Relaxation (aneleastic earth model/frequency-dependent shear velocity)", Proc. Nat. Acad. Sci., USA, v.68:7, p.1577, 3 pages (1971)
D.D. Jackson: "The Attenuation of Love Waves and Toroidal Oscillations of the Earth", Geophys. J. R.
Astron. Soc., v.25, p.25, 10 pages (1971)
D.D. Jackson and D.L. Anderson: "Physical Mechanisms of Seismic-Wave Attenuation", Rev.
Geophys. & Space Phys., v.8:1, p.1, 63 pages (1970)
D.D. Jackson: "Grain Boundary Relaxation and the Attenuation of Seismic Waves", Ph.D. Thesis, Dept. Earth and Planetary Science, M.I.T., 136 pages (1969)
D.D. Jackson: "An Elastic Relaxation Model for Seismic Wave Attenuation in the Earth", Phys. Earth Planet. Int., v.2, p.30, 5 pages (1969)
F. Press and D. Jackson: "Alaskan Earthquake, 27 March 1964: Vertical Extent of Faulting and Elastic Strain Energy Release", Science, v.147, p.109, 3 pages (1965)
1 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the matter of Pacific Gas and Electric Company Docket Nos. 50-275-LR Diablo Canyon Nuclear Power Plant 50-323-LR Units 1 and 2 SAN LUIS OBISPO MOTHERS FOR PEACE CERTIFICATE OF SERVICE I certify that on April 15, 2015, I posted on the NRCs Electronic Information Exchange SAN LUIS OBISPO MOTHERS FOR PEACES MOTION TO FILE NEW CONTENTIONS REGARDING ADEQUACY OF SEVERE ACCIDENT MITIGATION ALTERNATIVES ANALYSIS FOR DIABLO CANYON LICENSE RENEWAL APPLICATIONS and attached DECLARATION OF DR. DAVID D. JACKSON. It is my understanding that as a result, the NRC Commissioners, Atomic Safety and Licensing Board, and parties to this proceeding were served.
Respectfully submitted, Electronically signed by Diane Curran Harmon, Curran, Spielberg & Eisenberg, L.L.P.
1726 M Street N.W. Suite 600 Washington, D.C. 20036 202-328-3500 Fax: 202-328-6918 E-mail: dcurran@harmoncurran.com