ML15090A710
| ML15090A710 | |
| Person / Time | |
|---|---|
| Site: | Northwest Medical Isotopes, PROJ0803 |
| Issue date: | 04/02/2015 |
| From: | Northwest Medical Isotopes |
| To: | Office of Nuclear Reactor Regulation |
| Balazik, Michael 415-2856 | |
| References | |
| Download: ML15090A710 (13) | |
Text
1 1
U.S. Nuclear Regulatory Commission Pre Construction Permit Application Meeting Public Presentation April 2, 2015 11:00am - 12:00pm
2 Agenda April 2, 2015 Public Session 11:00am Opening Remarks (5 minutes)
NRC 11:05am NWMI Introductions and Project Status (10 minutes)
NWMI Facility Description (10 minutes)
Facility Licensing Approach (10 minutes)
Process Functions & Requirements and Facility Design Criteria (10 minutes)
Public Question and Answer Period (15 minutes)
NRC
3 NWMI INTRODUCTION AND PROJECT STATUS April 2, 2015
4 NWMI Introductions and Organization Irradiation Services - University Reactors Radioisotope Production Facility Partners Technology Demonstration Partners Carolyn Haass, Vice President Steve Reese, Irradiations Logistics Manager Marcus Voth, Technical Adviser John Andrzejczak, Chief Engineer Gary Dunford, Hot Cell Process Lead David Smith, Target Fabrication Lead Michael Corum, ISA/Shielding/Criticality Lead Engineering Design Licensing and Environmental Permitting Criticality, Shielding, and Safety Analysis Transportation
5 NWMI Project Status Construction Permit Application Received Exemption to Submit CP Application in 2 Parts (Oct 2013)
Part 1 complete and submitted Part 2 will be submitted in 2nd Q 2015 Facility preliminary design completed; initiating final design in 2nd Q 2015 Proof of concept tests have/are continuing to be performed Prototypic target production initiated/OSU license amendment submitted and awaiting NRC approval Siting Decision Taken; Option formalized Network of irradiation suppliers complete Strategic Partnerships and Major Subcontractor development complete
6 FACILITY DESCRIPTION April 2, 2015
7 Process Block Flow Diagram LEU target material is fabricated (both fresh LEU and recycled U)
LEU target material encapsulated using metal cladding LEU Target LEU targets are packaged and shipped to university reactors for irradiation After irradiation, targets are shipped back to RPF Irradiated LEU targets disassembled Irradiated LEU targets dissolved into a solution for processing Dissolved LEU solution is processed to recover and purify 99Mo Purified 99Mo is packaged/shipped to a radiopharmaceutical distributor LEU solution is treated to recover U and is recycled back to Step 1
8 Facility Description
1st Level footprint ~52,000 ft2 Target Fabrication Area Hot Cell Processing areas (e.g., Dissolution, 99Mo recovery, 235U recovery)
Waste Management, Laboratory and Utility Areas
2nd Level foot print ~17,000 ft2 (e.g., Utility, Ventilation, and Off-Gas Equipment)
WM Out Building (~1,200 ft2)
High bay roof - 65 ft Mach area roof - 46 ft Top of exhaust stack - 75 ft Loading dock (back) roof - 20 ft Support & Admin (front) roof - 12 ft Depth below grade for tank farm/HIC storage - 15 ft
Administration Building (outside of secured RPF area) ~10,000 ft2
9 FACILITY LICENSING APPROACH April 2, 2015
10 Licensing Approach NWMI will combine several license activities and submit one application that covers all applicable regulations for construction and operation of an RPF under 10 CFR 50
- Process 99Mo and recycle LEU under 10 CFR 50, Domestic Licensing of Production and Utilization Facilities
- Target fabrication (ability to receive, possess, use, and transfer of SNM) under 10 CFR 70, Domestic Licensing of SNM
- Ability to handle by-product material under 10 CFR 30, Rules of General Applicability to Domestic Licensing of Byproduct Material NWMIs understanding
- NRC will approve and issue one license under 10 CFR 50; Activities under 10 CFR 70 and 10 CFR 30 will be part of 10 CFR 50 license (10 CFR 50.31, Combining Applications)
- NRC will complete a single review process (10 CFR 50.32, Elimination of Repetition)
- Only interact with one group within NRC (e.g., administrative, license reviews and approvals, inspections) (10 CFR 50.32, Elimination of Repetition)
- Fees will only be assessed under 10 CFR 50 Other Integrated License Activities to support NWMIs RPF
- University Reactor(s) will amend their current operating licenses to support production of 99Mo
- Required transportation casks will be amended by NWMI (if necessary)
11 Facility Licensing Layout
10 CFR 50 Activities Irradiated Target receipt Irradiated target disassembly Target dissolution 99Mo separations, purification and packaging LEU reclamation and purification Waste management Associated laboratory and support
10 CFR 70 Activities Receipt of LEU (from DOE)
Production of LEU target material Target fabrication and testing Shipping/loading of fabricated targets Associated laboratory and support areas
10 CFR 30 Activities Handling of byproduct material
12 FACILITY ASSUMPTIONS AND CRITERIA April 2, 2015
13 RPF Primary Assumptions and Criteria Single RPF using LEU Irradiated targets generated by multiple reactors; Utilize same target design Individual target batch processing time from EOB 32 hr Uranium losses during process < 3 %
Recycling processed LEU for reuse as target material Fission product releases will comply with environmental release criteria Uranium processing and storage will meet all required Safeguards & Security Requirements Each unit process/function and sub process/function requirements have been identified Facility Design Criteria Document Complete Facility Process Functions & Requirements Document Complete Radioisotope Production Facility Process Fabricate Targets Handle Waste Recover Molybdenum Process Irradiated Targets Recover Uranium Support Systems NWMI-001r1 Receive New Uranium Produce Target Material Assemble Targets Handle Scrap Uranium Package and Ship Targets Accumulate Waste Treat Waste Package and Assay Waste Ship Waste Separate Molybdenum Purify Molybdenum Package and Ship Molybdenum Receive Irradiated Targets Disassemble Targets Dissolve Target Material Fission Product Gas Capture Receive Impure Uranium Purify Uranium Recycle Uranium Offgas Treatment Utilities and Consumables Laboratory