JOB PERFORMANCE MEASURE JPM Page 1 of 8 TR-AA-230-1003-F10, Revision 2 JPM TITLE:

REVIEW SHUTDOWN MARGIN CALCULATION FOR AN OPERATING REACTOR JPM NUMBER:

PBN JPM P000.002c.COT REV.

3 TASK NUMBER(S) /

TASK TITLE(S):

P000.002.COT / PERFORM SHUTDOWN MARGIN CALCULATION FOR AN OPERATING REACTOR K/A NUMBERS:

003AK1.07 003AK3.04 2.1.25 K/A VALUE:

3.1/3.9 3.8/4.1 3.9/4.2 Justification (FOR K/A VALUES <3.0):

TASK APPLICABILITY:

RO SRO STA Non-Lic SRO CERT OTHER:

APPLICABLE METHOD OF TESTING:

Simulate/Walkthrough:

Perform:

X EVALUATION LOCATION:

In-Plant:

Control Room:

Simulator:

X Other:

X Lab:

Time for Completion:

20 Minutes Time Critical:

No Alternate Path [NRC]:

Yes Alternate Path [INPO]:

Yes Developed by:

Jeffrey Hinze Instructor/Developer Date Reviewed by:

Andrew Zommers Instructor (Instructional Review)

Date Validated by:

Jeff Baugniet SME (Technical Review)

Date Approved by:

Randy Amundson Training Supervision Date Approved by:

Tom Larson Training Program Owner Date

PBN JPM P000.002c.COT, Review Shutdown Margin Calculation for an Operating Reactor, Rev. 3 JPM Page 2 of 8 TR-AA-230-1003-F10, Revision 2 I will explain the initial conditions, which step(s) to simulate or discuss, and provide initiating cues.

When you complete the task successfully, the objective for this job performance measure will be satisfied.

DURING THE JPM, ENSURE PROPER SAFETY PRECAUTIONS, FME, AND/OR RADIOLOGICAL CONCERNS AS APPLICABLE ARE FOLLOWED.

INITIAL CONDITIONS:

  • Unit 1 had been operating at 100% power.
  • Rod H-2 in Shutdown Bank "A" has dropped to the bottom of the core.
  • The crew is responding in accordance with AOP-6A, "Dropped Rod".
  • Assume todays date and time is current.

INITIATING CUES (IF APPLICABLE):

The following Unit 1 conditions currently exist:

  • Boron Concentration - 1275 ppm
  • Rx Power - 90%
  • Tave - 572 °F
  • Tref - 573 °F
  • Control Bank D @ 180 steps
  • All other banks @ 228 steps

JOB PERFORMANCE MEASURE JPM Page 3 of 8 JPM PERFORMANCE INFORMATION Start Time:

NOTE: When providing Evaluator Cues to the examinee, care must be exercised to avoid prompting the examinee. Typically cues are only provided when the examinees actions warrant receiving the information (i.e., the examinee looks or asks for the indication).

NOTE: Critical steps are marked with a Y below the performance step number. Failure to meet the standard for any critical step shall result in failure of this JPM.

NOTE: If the candidate attempts to stop evaluating the SDM after finding the first mistake, direct them to complete evaluating the entire SDM.

NOTE: Provide examinee with a copy of the Unit 1 ROD book with ROD 1.1 filled out for 2850 MWD/MTU five days ago. Also provide examinee with a copy of the TRM.

Performance Step: 1 Critical N Verify TAVG within 1.5°F of TREF.

Standard:

Verify TAVG within 1.5°F of TREF based on initial conditions given and YES circled on PBF-2513.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

JOB PERFORMANCE MEASURE JPM Page 4 of 8 Performance Step: 2 Critical N Verify Core Burn-Up from ROD 1.1.

Standard:

Core burn-up determined to be 3040 +/- 30 MWD/MTU (3010-3070).

Evaluator Note:

Core burn-up determined to be 3040 MWD/MTU and recorded on PBF-2513. From ROD 1.1, examinee will have 2850 MWD/MTU five days ago and will need to add 190 MWD/MTU (5 Days

  • 38 MWD/MTU/Day)

Evaluator Cue:

Provide examinee with a copy of Unit 1 ROD Book.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 3 Critical N Verify Nominal EOL Burn-Up from ROD1.1.

Standard:

EOL burn-up determined to be 18874 MWD/MTU as recorded on PBF-2513.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 4 Critical N Verify % Burn-Up.

Standard:

Verify % burn-up to be 16.11% + 0.16% (15.95-16.27) as recorded on PBF-2513.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

JOB PERFORMANCE MEASURE JPM Page 5 of 8 Performance Step: 5 Critical N Verify Reactor Power Level (%).

Standard:

Verify 90% as recorded on PBF-2513.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 6 Critical N Verify Control Rod Position Standard:

Bank C and D control rod position determined to be 228 and 180 steps as recorded on PBF-2513.

Evaluator Cue:

If asked Bank C is at 228 steps per initial conditions.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 7 Critical N Verify Power Defect from ROD 7.

Standard:

Determine that the power defect of 1480 pcm recorded on PBF-2513 is in error, and the value should be 1630 pcm + 30 pcm (1600-1660),

based on possible min/max reading on the graph.

Evaluator Note:

If the candidate attempts to stop evaluating the SDM after finding the first mistake, direct them to complete evaluating the entire SDM.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

JOB PERFORMANCE MEASURE JPM Page 6 of 8 Performance Step: 8 Critical N Verify Control Rod Worth (Bank D, C, B, A, S in, at HZP) from ROD

5.

Standard:

Verify control rod worth (Bank D, C, B, A, S in, at HZP) to be 6669 pcm as record on PBF-2513.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 9 Critical N Verify Stuck Rod Worth from ROD 5.

Standard:

Verify stuck rod worth to be 705 pcm as record on PBF-2513.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 10 Critical N Verify Stuck Rod Worth minus Control Rod Worth.

Standard:

Verify stuck rod worth minus control rod worth to be 5964 pcm as record on PBF-2513.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

JOB PERFORMANCE MEASURE JPM Page 7 of 8 Performance Step: 11 Critical Y Verify Bank Worth to ARO from ROD 3.1, Using Step 2 and Step 6 data.

Standard:

Determine bank worth to ARO of 129 pcm recorded on PBF-2513 to be in error and the value should be 147 pcm.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 12 Critical N Verify correct value for dropped rod, stuck rod or no abnormal condition.

Standard:

Verify dropped rod and Stuck Rod Worth from ROD 5 of 705 pcm as record on PBF-2513.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 13 Critical N Calculate Total Available Control Rod Negative Reactivity by adding Step 10, 11, 12 and 250 pcm.

Standard:

Verify Total available control rod negative reactivity of 4880 pcm recorded on PBF-2513 to be in error and the value should be 4862 pcm.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

JOB PERFORMANCE MEASURE JPM Page 8 of 8 Performance Step: 14 Critical Y Verify Shut Down Margin by adding Steps 13 and 7.

Standard:

Determine calculated SDM of 3400 pcm as recorded on PBF-2513 to be in error and the correct value should be 3232+ 30 pcm (3062-3202).

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 15 Critical N Verify the Required Shut Down Margin using TRM 2.1, [COLR]

Figure 2 using Step 4 data.

Standard:

Verify required SDM to be - 2000 pcm as record on PBF-2513.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 16 Critical N Verify if calculated Shut Down Margin is more negative than Required Shut Down Margin.

Standard:

Verify Calculated SDM is greater than Required SDM AND YES is circled on PBF-2513.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Terminating Cues:

This completes the JPM Stop Time:

JOB PERFORMANCE MEASURE JPM Page 1 of 10 TR-AA-230-1003-F10, Revision 2 JPM TITLE:

Review Weekly Power Availability Verification JPM NUMBER:

PBN JPM P119.210b.SRO REV. 0 TASK NUMBER(S) /

TASK TITLE(S):

PBN P119.210.SRO Review Operating Logs for Trends and Out-of-Specification Conditions K/A NUMBERS:

2.1.18 K/A VALUE: 3.6/3.8 Justification (FOR K/A VALUES <3.0):

TASK APPLICABILITY:

RO SRO STA Non-Lic SRO CERT OTHER:

APPLICABLE METHOD OF TESTING:

Simulate/Walkthrough:

Perform:

X EVALUATION LOCATION:

In-Plant:

Control Room:

Simulator:

Other:

X Lab:

Time for Completion:

30 Minutes Time Critical:

NO Alternate Path [NRC]:

YES Alternate Path [INPO]:

YES Developed by:

Andrew Zommers Instructor/Developer Date Reviewed by:

Jeff Hinze Instructor (Instructional Review)

Date Validated by:

Jeff Baugniet SME (Technical Review)

Date Approved by:

Randy Amundson Training Supervision Date Approved by:

Tom Larson Training Program Owner Date

PBN JPM P119.210b.SRO Review Weekly Power Availability Verification, Rev. 0 JPM Page 2 of 10 TR-AA-230-1003-F10, Revision 2 I will explain the initial conditions, which step(s) to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

DURING THE JPM, ENSURE PROPER SAFETY PRECAUTIONS, FME, AND/OR RADIOLOGICAL CONCERNS AS APPLICABLE ARE FOLLOWED.

INITIAL CONDITIONS:

You are the Unit 1 OS Unit 1 is in Mode 4 per OP 1A, Cold Shutdown to Hot Standby Unit 2 is in Mode 6, performing a core reload per RP 1C, Refueling 0-TS-EP-001 Weekly Power Availability Verification has just been completed INITIATING CUES (IF APPLICABLE):

The 4th License has provided 0-TS-EP-001, Weekly Power Availability Verification, for you to perform and document the completed procedure review.

JPM Page 3 of 10 TR-AA-230-1003-F10, Revision 2 JPM PERFORMANCE INFORMATION Start Time:

NOTE: When providing Evaluator Cues to the examinee, care must be exercised to avoid prompting the examinee. Typically cues are only provided when the examinees actions warrant receiving the information (i.e., the examinee looks or asks for the indication).

NOTE: Critical steps are marked with a Y below the performance step number. Failure to meet the standard for any critical step shall result in failure of this JPM.

NOTE: Examinee is expected to identify errors in the completed surveillance and determine the Technical Specification applicability/implications for these errors. This determination should identify the applicable LCOs, Action Conditions, and Required Actions.

Determining the exact time of Applicability and Associated Completion Time is NOT required for satisfactory performance. Identification of required cascading to Supported System LCO(s) per NP 10.3.8, Safety Function Determination Program, is not required for satisfactory performance.

Performance Step: 1 Critical N Conduct a completed procedure review of 0-TS-EP-001, Weekly Power Availability Verification, (Sections 4 through 6 and Attachment A through Attachment H, as applicable).

Standard:

The Examinee will review steps 5.2.1-5.2.11 and attachments A-H Evaluator Note:

This review is contained in the following JPM steps.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

JPM Page 4 of 10 TR-AA-230-1003-F10, Revision 2 Performance Step: 2 Critical Y 5.2.1 IF Unit 1 is in MODE 1, 2, 3, or 4, THEN CHECK the following 345/13.8 kV alignment:

a. CHECK 1X-03 is in service OR 2X-03 is in service with G05 operating and the 13kV bus tied across to Unit 1.
b. MARK results on Attachment A, Electrical Breaker Alignment And Power Availability Checks, 345/13.8 KV Alignment.

Standard:

The Examinee will verify that:

1. The Unit 1 meets the conditions (mode 1, 2, 3, or 4)
2. 1X-03 is in service OR 2X-03 is in service with G05 operating and the 13kV bus tied across to Unit 1, using Attachment A to verify 345/13.8 KV Alignment, AND note that 2X-03 is supplying 1X-04 and G-05 is NOT in operation.

Evaluator Note:

The Examinee should continue with the review of the completed surveillance given the current information.

Evaluator Cue:

If asked, Attachment A shows the current plant lineup Performance:

SATISFACTORY UNSATISFACTORY Comments:

JPM Page 5 of 10 TR-AA-230-1003-F10, Revision 2 Performance Step: 3 Critical Y 5.2.1 (contd)

c. IF this operability check is UNSAT, THEN REFER to Technical Specifications LCO 3.8.1 and LCO 3.8.9 for required actions.

Standard:

The examinee will identify the following LCOs/TSAC/RAs

1. LCO 3.8.1, AC Sources - Operating
2. TSAC 3.8.1.A, Gas turbine not in operation when utilizing opposite units 345/13.8kV (X03) transformer
3. RA A.1, Verify one circuit between the offsite transmission network and the associated units 4.16kV Class 1E safeguards buses, A05 and A06, utilizing the opposite units 345/13.8kV (X03) transformer
4. RA A.2, Verify gas turbine in operation Evaluator Note:

Identification of required cascading to Supported System LCO(s) per NP 10.3.8, Safety Function Determination Program, is not required for satisfactory performance.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 4 Critical N 5.2.2 IF Unit 2 is in MODE 1, 2, 3, or 4, THEN CHECK the following 345/13.8 kV alignment:

Standard:

The Examinee will verify that Unit 2 does not meet this condition, and step 5.2.2 is properly filled out.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

JPM Page 6 of 10 TR-AA-230-1003-F10, Revision 2 Performance Step: 5 Critical N 5.2.3 IF both units are in MODE 1, 2, 3, or 4, THEN PERFORM AC breaker alignment check on Attachment B, Electrical Breaker Alignment And Power Availability Checks, Units in MODE 1, 2, 3, or 4, as follows:

Standard:

The Examinee will verify that BOTH Units do not meet this condition, and step 5.2.3 is properly filled out.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 6 Critical N 5.2.4 IF Unit 1 is in MODE 1, 2, 3, or 4 AND Unit 2 is in MODE 5, 6 or defueled THEN PERFORM AC breaker alignment check on Attachment C, Electrical Breaker Alignment And Power Availability Checks, Unit 1 in MODE 1, 2, 3, or 4 and Unit 2 in MODE 5, 6 or defueled, as follows:

Standard:

The Examinee will verify that BOTH Units meet this condition, and step 5.2.4 and Attachment C are properly filled out.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 7 Critical N 5.2.5 IF Unit 1 is in MODE 5, 6 or defueled AND Unit 2 is in MODE 1, 2, 3, or 4, THEN PERFORM AC breaker alignment check on Attachment D, Electrical Breaker Alignment And Power Availability Checks, Unit 1 in MODE 5, 6 or defueled and Unit 2 in MODE 1, 2, 3, or 4, as follows:

Standard:

The Examinee will verify that BOTH Units do not meet this condition, and step 5.2.5 is properly filled out.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

JPM Page 7 of 10 TR-AA-230-1003-F10, Revision 2 Performance Step: 8 Critical N 5.2.6 IF both units are in MODE 5, 6 or defueled, THEN PERFORM AC breaker alignment check on Attachment E, Electrical Breaker Alignment And Power Availability Checks, Each Unit in MODE 5, 6 or defueled, as follows:

Standard:

The Examinee will verify that BOTH Units do not meet this condition, and step 5.2.6 is properly filled out.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 9 Critical N 5.2.7 IF any unit is in MODE 1, 2, 3, or 4, THEN PERFORM a 125 V DC Bus alignment check on Attachment F, Electrical Breaker Alignment And Power Availability Checks, 125 V DC Buses.

Standard:

The Examinee will verify that a Unit meets this condition, and step 5.2.7 and Attachment F are properly filled out.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 10 Critical N 5.2.8 IF both units are in MODE 5 or 6 or Defueled, THEN PERFORM a 125 V DC Bus alignment check on Attachment F, Electrical Breaker Alignment And Power Availability Checks, 125 V DC Buses.

Standard:

The Examinee will verify that BOTH Units do not meet this condition, and step 5.2.8 is properly filled out.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

JPM Page 8 of 10 TR-AA-230-1003-F10, Revision 2 Performance Step: 11 Critical N 5.2.9 IF any unit is in MODE 1, 2, 3, or 4, THEN PERFORM a 120 V AC Vital Instrument Bus alignment check on 2C20 Panel for the applicable unit as follows:

Standard:

The Examinee will verify that a Unit meets this condition, and step 5.2.9 and attachment G are properly filled out.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 12 Critical Y 5.2.10 IF any unit is in MODE 5 or 6 or Defueled THEN PERFORM a 120 V AC Vital Instrument Bus alignment check on 2C20 Panel for the applicable unit as follows:

a. CHECK power availability to the 120 V AC Vital Instrument Buses listed on Attachment G, Electrical Breaker Alignment And Power Availability Checks, 120 V AC Vital Instrument Buses.
b. CHECK 120 V AC Vital Bus Inverter power is operable to equipment required to be operable as specified by LCO 3.8.8 and LCO 3.8.10.

Standard:

The Examinee will determine this is NOT met due to 2DY-01 being shifted to the Backup Source Evaluator Note:

The sub steps of 5.2.10 noted above are the steps which are UNSAT (incorrect). All other sub step in 5.2.10 are SAT (correct) and not included.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

JPM Page 9 of 10 TR-AA-230-1003-F10, Revision 2 Performance Step: 13 Critical Y 5.2.10 (contd)

d. IF this operability check is UNSAT, THEN REFER to Technical Specifications LCO 3.8.8 and LCO 3.8.10 for required actions.

Standard:

The Examinee will identify the following LCOs/TSAC/RAs

1. LCO 3.8.8, Inverters - Shutdown
2. TSAC 3.8.8.A, One or more required inverters inoperable.
3. RA A.1, Declare affected require feature(s) inoperable
4. RA A.2 Initiate action to restore required inverters to OPERABLE status Evaluator Note:

Identification of required cascading to Supported System LCO(s) per NP 10.3.8, Safety Function Determination Program, is not required for satisfactory performance.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 14 Critical N 5.2.11 RECORD electrical bus voltages as listed on Attachment H, Electrical Breaker Alignment And Power Availability Checks, Bus Voltages.

Standard:

The Examinee will verify that a Unit meets this condition, and step 5.2.11 and attachment H are properly filled out.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

JPM Page 10 of 10 TR-AA-230-1003-F10, Revision 2 Performance Step: 15 Critical N Inform the Shift Manager and/or 4th License of any actions required.

Standard:

The Examinee informs the SM and or 4th License of discrepancies identified.

Evaluator Note:

If an assessment of Technical Specifications is performed here see JPM steps 3 and 13 for the Technical Specifications identified in the JPM Evaluator Cue:

Acknowledge the report from the Examinee If NO assessment of Technical Specifications was performed by the Examinee, ask for an assessment of Technical Specifications given the errors identified by the Examinee.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Terminating Cues:

Stop Time:

JOB PERFORMANCE MEASURE JPM Page 1 of 12 TR-AA-230-1003-F10, Revision 2 JPM TITLE:

Complete a Technical Specification and Administrative Action Condition Logsheet PBF-9133 JPM NUMBER:

PBN P119.203.SRO REV.

2 TASK NUMBER(S) /

TASK TITLE(S):

P119.203.SRO Maintain Required Logs and Records K/A NUMBERS:

2.2.23 K/A VALUE:

3.1/4.6 Justification (FOR K/A VALUES <3.0):

TASK APPLICABILITY:

RO SRO STA Non-Lic SRO CERT OTHER:

APPLICABLE METHOD OF TESTING:

Simulate/Walkthrough:

Perform:

X EVALUATION LOCATION:

In-Plant:

Control Room:

Simulator:

X Other:

X Lab:

Time for Completion:

20 Minutes Time Critical:

No Alternate Path [NRC]:

No Alternate Path [INPO]:

No Developed by:

Jeffrey Hinze Instructor/Developer Date Reviewed by:

Andrew Zommers Instructor (Instructional Review)

Date Validated by:

Jeff Baugniet SME (Technical Review)

Date Approved by:

Randy Amundson Training Supervision Date Approved by:

Tom Larson Training Program Owner Date

JOB PERFORMANCE MEASURE JPM Page 2 of 12 TR-AA-230-1003-F10, Revision 2 I will explain the initial conditions, which step(s) to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

DURING THE JPM, ENSURE PROPER SAFETY PRECAUTIONS, FME, AND/OR RADIOLOGICAL CONCERNS AS APPLICABLE ARE FOLLOWED.

INITIAL CONDITIONS:

  • Unit 1 is in Mode 3.
  • Current work week number is 1508.
  • 1P-53 Motor Driven Auxiliary Feedwater pump was removed from service 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> ago for testing IAW IT 400, Test Of 1P-53 Motor-Driven Auxiliary Feed Pumps And Valves.
  • During the testing of 1P-53 Motor Driven Auxiliary Feedwater pump it was determined that the motor vibrations were above the acceptable limits.
  • It has been determined the pump will not be returned to service for approximately 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />.

AR01234567, 1P-53 failed surveillance testing, was written to document the failure and WO76543210 was generated to repair the motor.

  • No other equipment is currently out of service.

INITIATING CUES (IF APPLICABLE):

  • The Shift Manager has directed you to document LCO tracking in accordance with NP 10.1.1, Tech Spec and Administrative LCO Action Condition Entry and Tacking.

NOTE: Evaluator Note: Only provide a copy of NP 10.1.1 and NOT PBF-9133 until requested by examinee.

JOB PERFORMANCE MEASURE JPM Page 3 of 12 TR-AA-230-1003-F10, Revision 2 JPM PERFORMANCE INFORMATION Start Time:

NOTE: When providing Evaluator Cues to the examinee, care must be exercised to avoid prompting the examinee. Typically cues are only provided when the examinees actions warrant receiving the information (i.e., the examinee looks or asks for the indication).

NOTE: Critical steps are marked with a Y below the performance step number.

Failure to meet the standard for any critical step shall result in failure of this JPM.

Performance Step: 1 Critical N Reference NP 10.1.1 and start at Step 4.1 Standard:

Obtain current revision of procedure and determine steps 4.1.1 and 4.1.2 are not applicable to 1P-53 and start with step 4.1.3 to start tracking with PBF-9133.

Evaluator Note:

A completed PBF-9133 Answer Key is attached.

Evaluator Cue:

Provide NP 10.1.1 and a blank PBF-9133 as requested by examinee or examinee references how to get current revision.

Examinee may also request NP 10.3.8 at this time.

Any time in this process the examinee may ask if LCO 3.0.6 will be invoked. The Shift Manager has determined NOT to invoke LCO 3.0.6.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

JOB PERFORMANCE MEASURE JPM Page 4 of 12 TR-AA-230-1003-F10, Revision 2 Performance Step: 2 Critical N Assigns next Action Condition Index Number to form PBF-9133 and documents in Index PBF-9133e.

Standard:

Obtains next Action Condition Index number from PBF-9133e located in TSAC Tracking binder and record on form per step 4.1.3.

Evaluator Note:

Examinee should determine note applies due to AR being written for failed testing.

Evaluator Cue:

Provide examinee the next index number of 01-15-006 and tell them the Shift Manager will complete the PBF-9133e index.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 3 Critical Y Indicate Action Condition Status (active or potential).

Standard:

Records Condition status as ACTIVE on PBF-9133.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

JOB PERFORMANCE MEASURE JPM Page 5 of 12 TR-AA-230-1003-F10, Revision 2 Performance Step: 4 Critical Y Record the applicable document reference.

Standard:

Examinee obtains a copy of Technical Specifications and Bases to determine that LCO 3.7.5 is applicable.

Evaluator Note:

As a minimum, examinee satisfies critical step performance by indicating LCO 3.7.5 is applicable in either the Document references OR the Condition and Reason for OOS block. Other information may be provided.

Evaluator Cue:

Provide examinee a copy of Technical Specifications and Bases as requested.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 5 Critical N Record the work week number for which the activity is scheduled.

Standard:

Examinee records current work week due to short TSAC time.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

JOB PERFORMANCE MEASURE JPM Page 6 of 12 TR-AA-230-1003-F10, Revision 2 Performance Step: 6 Critical Y Records Date and Time entered.

Standard:

Examinee records current date and time of approximately 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> from JPM start.

Evaluator Note:

The Examinee should determine the current record started 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> ago, and may estimate additional time for the paperwork in this estimate.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 7 Critical N Record present Mode for applicable unit/units.

Standard:

Examinee records Mode 3 for Unit 1.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 8 Critical N Record Operational Condition Applicability (mode or other specified condition) for the Action Condition.

Standard:

Examinee records Modes 1, 2, 3, and 4 when SG relied upon for heat removal in Applicability block per LCO 3.7.5.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

JOB PERFORMANCE MEASURE JPM Page 7 of 12 TR-AA-230-1003-F10, Revision 2 Performance Step: 9 Critical Y Determine if a Mode change is allowed per TS 3.0.4 with this condition.

Standard:

Examinee determines that TS 3.0.4 is NOT applicable.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 10 Critical N Record the equipment description.

Standard:

Examinee records 1P-53 MDAFW Pump (or equivalent wording) in Equipment Name/ID Block.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 11 Critical N Record any other applicable references.

Standard:

Determine no other applicable references required or list additional references as desired.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

JOB PERFORMANCE MEASURE JPM Page 8 of 12 TR-AA-230-1003-F10, Revision 2 Performance Step: 12 Critical Y State the reason for the SSC Condition in the Summary Description section and a brief summary of all actions required.

Standard:

TSAC 3.7.5.B required actions for listed TSAC and completion time/clock time for TSAC.

Evaluator Note:

Recorded information wording may vary from key provided the correct TSAC, Required Actions, and Completion times are correctly recorded for Condition B.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 13 Critical N Initiate required departmental notifications for required compensatory actions and document person contacted with time, date, and reason for contact.

Standard:

Examinee determines there are not any required compensatory actions required and leaves this section blank.

Evaluator Cue:

If asked, the Shift Manager determined there are no compensatory measures to be put in place at this time.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

JOB PERFORMANCE MEASURE JPM Page 9 of 12 TR-AA-230-1003-F10, Revision 2 Performance Step: 14 Critical N If any LCO is NOT met then perform a SFDP Screening using NP 10.3.8, Safety Function Determination Program.

Standard:

Records a Y in any LCO not met block and determines a SFDP screening is required using NP 10.3.8.

Evaluator Cue:

Provide examinee with copy of NP 10.3.8 when they describe how a current revision of the procedure would be obtained.

Any time in this process the examinee may ask if LCO 3.0.6 will be invoked. The Shift Manager has determined NOT to invoke LCO

3.0.6. Performance

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 15 Critical N Performs SFDP screening using NP 10.3.8 Standard:

Examinee performs SFDP Screening and determines that no Loss of Safety Function evaluation is required.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

JOB PERFORMANCE MEASURE JPM Page 10 of 12 TR-AA-230-1003-F10, Revision 2 Performance Step: 16 Critical N Current LOSF evaluation exists Standard:

Reviews other equipment out of service and determines no current LOSF exists.

Evaluator Cue:

If asked, there is no other equipment currently out of service as stated in the initial conditions Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 17 Critical N Condition or Inoperable SSC affects on-line Safety Monitor.

Standard:

Determines or asks STA if this equipment affects the on-line Safety Monitor and request review using NP 10.3.7, indicating a Y in this block.

Evaluator Cue:

The Shift Technical Advisor will conduct an on-line safety assessment per NP 10.3.7.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

JOB PERFORMANCE MEASURE JPM Page 11 of 12 TR-AA-230-1003-F10, Revision 2 Performance Step: 18 Critical N If the LCO/TLCO NOT met is involuntary then initiate an AR and make proper notifications to the DCS and NRC Resident.

Standard:

Examinee indicates the LCO being not met is involuntary and notifications are required.

Evaluator Note:

An AR was previously submitted per the Initial Conditions Evaluator Cue:

Inform examinee that the Shift Manager has informed the DCS and NRC Resident of the situation.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 19 Critical N Determine if Fire Rounds are required per OM 3.27 Standard:

Examinee indicates that fire rounds are not required per OM 3.27.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step: 20 Critical Y Ensure that all applicable Work Orders, ARs, Tag Series, Plant Modifications, overdue Technical Specification surveillances, overdue equipment PMs, etc are entered on the Work Order and Clearance Addendum.

Standard:

Examinee lists the AR and WO on the addendum sheet.

Evaluator Note:

Responsible group is not critical Performance:

SATISFACTORY UNSATISFACTORY Comments:

JOB PERFORMANCE MEASURE JPM Page 12 of 12 TR-AA-230-1003-F10, Revision 2 Performance Step: 21 Critical N The OS/WCC SRO shall ensure the Action Condition Log Sheet data is complete. When satisfactorily completed sign, date and time the log sheet.

Standard:

Examinee reports that the PBF-9133 is completed and ready for the AFW pump.

Evaluator Cue:

This completes the JPM.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Terminating Cues:

Stop Time:

JOB PERFORMANCE MEASURE JPM Page 1 of 6 TR-AA-230-1003-F10, Revision 2 JPM TITLE:

REVIEW RELEASE PERMIT JPM NUMBER:

PBN JPM P119.212.SRO REV.

2 TASK NUMBER(S) /

TASK TITLE(S):

P119.212.SRO/Approve Radioactive Waste Discharge Permits K/A NUMBERS:

2.3.6 K/A VALUE:

2.0/3.8 Justification (FOR K/A VALUES <3.0):

TASK APPLICABILITY:

RO SRO STA Non-Lic SRO CERT OTHER:

APPLICABLE METHOD OF TESTING:

Simulate/Walkthrough:

Perform:

X EVALUATION LOCATION:

In-Plant:

Control Room:

Simulator:

X Other:

X Lab:

Time for Completion:

15 Minutes Time Critical:

No Alternate Path [NRC]:

No Alternate Path [INPO]:

No Developed by:

Jeffrey Hinze Instructor/Developer Date Reviewed by:

Andrew Zommers Instructor (Instructional Review)

Date Validated by:

Jeff Baugniet SME (Technical Review)

Date Approved by:

Randy Amundson Training Supervision Date Approved by:

Tom Larson Training Program Owner Date

PBN JPM P119.212.SRO, Review Release Permit, Rev. 2 JPM Page 2 of 6 TR-AA-230-1003-F10, Revision 2 I will explain the initial conditions, which step(s) to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

DURING THE JPM, ENSURE PROPER SAFETY PRECAUTIONS, FME, AND/OR RADIOLOGICAL CONCERNS AS APPLICABLE ARE FOLLOWED.

INITIAL CONDITIONS:

  • Both Units are at rated thermal power with no equipment out of service.
  • Unit 2 started a forced vent yesterday 2/22/15 at 1800.
  • The forced vent was interrupted this morning 2/23/15 at 0500 due to RP testing.
  • 2RE-211 and 2RE-212 have remained in operation throughout the testing evolution.

INITIATING CUES (IF APPLICABLE):

  • You are OS2 today and it is 0900 with the RP testing completed.
  • All other RMS monitors have been in service for the past 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
  • The Shift Manager has requested that you approve a restart of the forced vent on Unit 2.
  • Additionally, the following data is provided:

RAD MONITOR STEADY STATE READINGS CHECK SOURCE READINGS 2RE-211 (Cont Air Part) 1.98 E-3 3.20 E-2 2RE-212 (Cont Gas) 7.45 E-6 2.80 E-4

JOB PERFORMANCE MEASURE JPM Page 3 of 6 TR-AA-230-1003-F10, Revision 2 JPM PERFORMANCE INFORMATION Start Time:

NOTE: When providing Evaluator Cues to the examinee, care must be exercised to avoid prompting the examinee. Typically cues are only provided when the examinees actions warrant receiving the information (i.e., the examinee looks or asks for the indication).

NOTE: Critical steps are marked with a Y below the performance step number. Failure to meet the standard for any critical step shall result in failure of this JPM.

Performance Step: 1 Critical N Review provided procedure and release permit Standard:

Review provided procedures Performance:

SATISFACTORY _____ UNSATISFACTORY _____

Comments:

Performance Step: 2 Critical N ENSURE 2RE-211 (DAM 2-2) and 2RE-212 (DAM 2-3) have been in operation for at least ten minutes.

Standard:

Ensure RE-211 and RE-212 have been in operation for ten minutes.

Evaluator Note:

Per initial conditions, RE-211 and RE-212 have been in operation the last 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

Performance:

SATISFACTORY _____ UNSATISFACTORY _____

Comments:

JOB PERFORMANCE MEASURE JPM Page 4 of 6 TR-AA-230-1003-F10, Revision 2 Performance Step: 3 Critical Y OBTAIN and RECORD SS data values from the following RMS monitors:

  • RE-211 (DAM 2-2)
  • RE-212 (DAM 2-3)

Standard:

Record values for RE-211 and RE-212 given in initial conditions/initiating cues.

Performance:

SATISFACTORY _____ UNSATISFACTORY _____

Comments:

Performance Step: 4 Critical Y OBTAIN and RECORD source check readings from the following RMS monitors:

  • RE-211 (DAM 2-2)
  • RE-212 (DAM 2-3)

Standard:

Record values for RE-211 and RE-212 given in initial conditions/initiating cues.

Performance:

SATISFACTORY _____ UNSATISFACTORY _____

Comments:

Performance Step: 5 Critical N CHECK a positive rise over the initial data value is indicated during the source check of the following RMS monitors:

  • RE-211 (DAM 2-2)
  • RE-212 (DAM 2-3)

Standard:

Determine positive rise in value from information given in initial conditions/initiating cues.

Performance:

SATISFACTORY _____ UNSATISFACTORY _____

Comments:

JOB PERFORMANCE MEASURE JPM Page 5 of 6 TR-AA-230-1003-F10, Revision 2 Performance Step: 6 Critical N CHECK SS data values have returned to initial values for the following RMS monitors to ENSURE source did NOT stick:

  • RE-211 (DAM 2-2)
  • RE-212 (DAM 2-3)

Standard:

Check values for RE-211 and RE-212 returned to normal.

Evaluator Cue:

Values for RE-211 and RE-212 have returned to the values given in initial conditions.

Performance:

SATISFACTORY _____ UNSATISFACTORY _____

Comments:

Performance Step: 7 Critical N Compare the RE-211 (DAM 2-2) and RE-212 (DAM 2-3) readings taken in Step 5.1.4.b with the readings for RE-211 and RE-212 in Step 5.1.1.h.

Standard:

Compare readings in steps 5.1.4.b with 5.1.1.h and determine the difference in readings.

Performance:

SATISFACTORY _____ UNSATISFACTORY _____

Comments:

JOB PERFORMANCE MEASURE JPM Page 6 of 6 TR-AA-230-1003-F10, Revision 2 Performance Step: 8 Critical Y IF any reading in Step 5.1.4.b is greater than 125% of associated reading in Step 5.1.1.h, THEN TERMINATE U2 vent per section 5.1.2 AND N/A Steps 5.1.4.h through 5.1.4.l.

Standard:

Take action to terminate forced vent per Step 5.1.2 and N/A Steps 5.1.4.h through 5.1.4.l.

Evaluator Note:

If examinee does not identify readings >125%, he/she will:

  • Direct the AO/RP to start the air sampler pump and record sampler rate on permit
  • Direct the RO to open 2RM-3200N, Forced Vent Pump Suction
  • Direct the RO to start the forced vent blower
  • Direct the RO to record the vent flow rate on the forced vent permit At that point the JPM can be terminated.

Performance:

SATISFACTORY _____ UNSATISFACTORY _____

Comments:

Performance Step: 9 Critical N Inform Shift Manager of the need to secure the forced vent on Unit 2.

Standard:

Shift Manager informed if need to secure forced vent.

Evaluator Cue:

Acknowledge report.

Performance:

SATISFACTORY _____ UNSATISFACTORY _____

Comments:

Terminating Cues:

Evolution complete Stop Time:

JOB PERFORMANCE MEASURE JPM Page 1 of 8 TR-AA-230-1003-F10, Revision 2 JPM TITLE:

PERFORM REQUIRED NOTIFICATIONS JPM NUMBER:

PBN JPM P119.214c.SRO REV.

3 TASK NUMBER(S) /

TASK TITLE(S):

P119.214.SRO / PERFORM REQUIRED NOTIFICATIONS K/A NUMBERS:

2.4.29 2.4.40 K/A VALUE:

3.1/4.4 2.7/4.5 Justification (FOR K/A VALUES <3.0):

TASK APPLICABILITY:

RO SRO STA Non-Lic SRO CERT OTHER:

APPLICABLE METHOD OF TESTING:

Simulate/Walkthrough:

Perform:

X EVALUATION LOCATION:

In-Plant:

Control Room:

Simulator:

X Other:

X Lab:

Time for Completion:

13 Minutes Time Critical:

Yes Alternate Path [NRC]:

No Alternate Path [INPO]:

No Developed by:

Jeffrey Hinze Instructor/Developer Date Reviewed by:

Andrew Zommers Instructor (Instructional Review)

Date Validated by:

Jeff Baugniet SME (Technical Review)

Date Approved by:

Randy Amundson Training Supervision Date Approved by:

Tom Larson Training Program Owner Date

PBN JPM P119.214c.SRO, Perform Required Notifications, Rev. 3 JPM Page 2 of 8 TR-AA-230-1003-F10, Revision 2 I will explain the initial conditions, which step(s) to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

DURING THE JPM, ENSURE PROPER SAFETY PRECAUTIONS, FME, AND/OR RADIOLOGICAL CONCERNS AS APPLICABLE ARE FOLLOWED.

INITIAL CONDITIONS:

You are participating in an ERO Team Training Drill. The following conditions exist in the Simulator.

Unit 1 and Unit 2 were operating at 100% normal steady-state conditions.

An RCS leak occurred inside containment on Unit 1 which led to trip criteria per the AOPs.

Shift management ordered a Unit 1 trip 10 minutes ago.

The RO tried to trip the reactor manually with both sets of pushbuttons unsuccessfully.

An AO has been dispatched to open the Unit 1 reactor trip breakers locally.

An automatic Safety Injection has occurred on low Pressurizer pressure.

The only radiation monitors indicating elevated readings are inside containment on Unit 1.

The Crew is responding in accordance with the Critical Safety Procedures (CSPs).

It is 1141, 4 Dec 2014, and the Shift Manager has just declared a Site Area Emergency classification in accordance with EAL SS2.1, Indications exist that automatic and manual trip were NOT successful.

PPCS page 2226 (3226) indicates as shown INITIATING CUES (IF APPLICABLE):

  • The Shift Manager (Emergency Director) has directed you to complete the Nuclear Accident Reporting System (NARS) Form through, and including, Box 11 and return the form to him for his authorization signature per EPIP 1.1, Course of Actions, Section 10.

This JPM is time critical.

JOB PERFORMANCE MEASURE JPM Page 3 of 8 TR-AA-230-1003-F10, Revision 2 JPM PERFORMANCE INFORMATION Start Time:

NOTE: JPM is TIME CRITICAL. Record Start Time as the time turnover to the student is complete.

NOTE: When providing Evaluator Cues to the examinee, care must be exercised to avoid prompting the examinee. Typically cues are only provided when the examinees actions warrant receiving the information (i.e., the examinee looks or asks for the indication).

NOTE: Critical steps are marked with a Y below the performance step number. Failure to meet the standard for any critical step shall result in failure of this JPM.

Performance Step: 1 Critical N Fill out heading Standard:

The Examinee:

Circles CR Circles requires Performance:

SATISFACTORY _____ UNSATISFACTORY _____

Comments:

Performance Step: 2 Critical Y Box 1 Initial Notification Standard:

The Examinee checks the Yes box Performance:

SATISFACTORY _____ UNSATISFACTORY _____

Comments:

JOB PERFORMANCE MEASURE JPM Page 4 of 8 TR-AA-230-1003-F10, Revision 2 Performance Step: 3 Critical Y Box 2 Status Standard:

The Examinee checks the [B] Drill/Exercise box Performance:

SATISFACTORY _____ UNSATISFACTORY _____

Comments:

Performance Step: 4 Critical N Box 3 Affected Station Standard:

The Examine ensures the [B] Point Beach box is checked Performance:

SATISFACTORY _____ UNSATISFACTORY _____

Comments:

Performance Step: 5 Critical N Box 4 Onsite Classification Standard:

The Examinee ensures the [C] Site Area Emergency box is checked Performance:

SATISFACTORY _____ UNSATISFACTORY _____

Comments:

JOB PERFORMANCE MEASURE JPM Page 5 of 8 TR-AA-230-1003-F10, Revision 2 Performance Step: 6 Critical Y Box 5 Standard:

The Examinee:

Ensures the [A] Classification box is checked Enters 1141, 4 Dec 2014 (per the Initial Conditions provided to the student)

Enters the EAL# SS2.1 Performance:

SATISFACTORY _____ UNSATISFACTORY _____

Comments:

Performance Step: 7 Critical Y Box 6 Event Release Status Standard:

The Examinee checks the [A] None box Evaluator Note:

Indicates whether a radioactive release is occurring. The definition of radioactive release is the release of radioactive material to the environment attributable to the event. Examples are given on back of NARS form.

Performance:

SATISFACTORY _____ UNSATISFACTORY _____

Comments:

Performance Step: 8 Critical Y Box 7 Type of Release Standard:

The Examinee checks the [A] Not Applicable box Performance:

SATISFACTORY _____ UNSATISFACTORY _____

Comments:

JOB PERFORMANCE MEASURE JPM Page 6 of 8 TR-AA-230-1003-F10, Revision 2 Performance Step: 9 Critical Y Box 8 Wind Direction Standard:

The Examinee:

Enters the From _____Degrees value (303.8°)

Circles the affected sectors (EFGH)

Evaluator Note:

10M and 45M Met data is provided. Per Box 8 instructions on the back of the NARS from, NOTE 1 states: Use 10M Met data unless dose assessment used 45M data.

Evaluator Cue:

If the Examinee asks about a Dose Assessment, state that this is the initial report.

Performance:

SATISFACTORY _____ UNSATISFACTORY _____

Comments:

Performance Step: 10 Critical Y Box 9 Wind Speed & Stability Class Standard:

The Examinee:

Enters the Miles/Hr.: _____ value (12.6 mph)

Circles the applicable Stability Class (E)

Evaluator Note:

10M and 45M Met data is provided. Per Box 9 instructions on the back of the NARS from, NOTE 1 states: Use 10M Met data unless dose assessment used 45M data.

Evaluator Cue:

If the Examinee asks about a Dose Assessment, state that this is the initial report.

Performance:

SATISFACTORY _____ UNSATISFACTORY _____

Comments:

JOB PERFORMANCE MEASURE JPM Page 7 of 8 TR-AA-230-1003-F10, Revision 2 Performance Step: 11 Critical Y Box 10 Protective Action Recommendations Standard:

The Examinee checks the [A] None box Performance:

SATISFACTORY _____ UNSATISFACTORY _____

Comments:

Performance Step: 12 Critical Y Box 11 Additional Information Standard:

The Examinee enters a description of the EAL being implemented, Indications exist that automatic and manual trip were NOT successful.

Evaluator Note:

The Examinee at a minimum describes the EAL being implemented (wording is not required to be exact).

Performance:

SATISFACTORY _____ UNSATISFACTORY _____

Comments:

JOB PERFORMANCE MEASURE JPM Page 8 of 8 TR-AA-230-1003-F10, Revision 2 Performance Step: 13 Critical Y Return the form to the Emergency Director for approval.

Standard:

The Examinee returns the form (Boxes 1 through 11 completed) to the Shift Manager (Emergency Director) for his review and approval within 15 min.

Evaluator Note:

Time is counted from the completion of the turn over (Start Time) to the time the form is turned over to the Shift Manages (ED).

Performance:

SATISFACTORY _____ UNSATISFACTORY _____

Comments:

Terminating Cues:

The Evolution is complete.

Stop Time: