ML14349A007

From kanterella
Jump to navigation Jump to search

Transmittal Email, Proprietary Request for Additional Information Email, Time-Limited Aging Analysis Regarding Reactor Vessel Internals
ML14349A007
Person / Time
Site: Arkansas Nuclear 
Issue date: 12/12/2014
From: Andrea George
Plant Licensing Branch IV
To: David Bice, Pyle S
Entergy Operations
George A
References
TAC MF4203
Download: ML14349A007 (1)


Text

From:

George, Andrea To:

"BICE, DAVID B (ANO)"; "CLARK, ROBERT W" Cc:

"PYLE, STEPHENIE L"

Subject:

OFFICIAL USE ONLY - SENSITIVE PROPRIETARY - Request for Additional Information - ANO, Unit 1 - Time-Limited Aging Analysis Regarding Reactor Vessel Internals - TAC NO. MF4203 Date:

Friday, December 12, 2014 2:30:00 PM Attachments:

RAIs (prop).pdf OFFICIAL USE ONLY - SENSITIVE PROPRIETARY (in email attachment)

Mr. Bice,

By letter dated May 6, 2014 (contains sensitive proprietary information, publicly available portions at Agencywide Documents Access and Management System (ADAMS) Accession Package No. ML14126A816), Entergy Operations, Inc. (Entergy, the licensee), submitted the Time-Limited Aging Analysis Regarding Reactor Vessel Internals Loss of Ductility for ANO, Unit 1, for NRC review. This report was submitted prior to entering the period of extended operation for ANO, Unit 1, as a result of the license renewal process.

During its review, the NRC staff has identified further information needed in order to complete its evaluation. Draft RAIs were transmitted to your staff on December 2, 2014, and I was notified via email that a clarification call was not needed. During a phone call with Ms. Pyle, it was agreed that an RAI response would be provided within 45 days, which is January 26, 2015.

Upon separation from the attachment, this email is non-proprietary.

Sincerely,

Andrea George Project Manager Nuclear Regulatory Commission Division of Operating Reactor Licensing andrea.george@nrc.gov 301-415-1081

OFFICIAL USE ONLY - SENSITIVE PROPRIETARY (in email attachment)