ML14324A768

From kanterella
Jump to navigation Jump to search
Email Dtd 11/17/14 Fr R. Mckinley to M. Lampert Response to Your Questions Dated 11/05/2014
ML14324A768
Person / Time
Site: Pilgrim
Issue date: 11/17/2014
From: Raymond Mckinley
Division Reactor Projects I
To: Lampert M
- No Known Affiliation
References
Download: ML14324A768 (2)


Text

1 Haverkamp, Trisha From:

McKinley, Raymond Sent:

Monday, November 17, 2014 2:55 PM To:

mary.lampert@comcast.net

Subject:

Response To Your Questions Dated 11/05/2014

Mary, The responses to your questions received on 11/05/2014 are provided below.

Sincerely, Ray McKinley Chief, Division of Reactor Projects Branch 5 U.S. NRC Region I

1. WhenisEntergydoingtheirtestrunforspentfueltransfer?

Yes,priortotheirinitialloading,Entergywillbeperformingaseriesonpreoperationaltests/internalpractices, oftenreferredtoasdryruns.Entergyhaselectedtodividetheprocessfordrycaskstorageintothefollowing fourdiscreteparts:

Part1WeldingandNonDestructiveExaminations(NDE)ofthemultipurposecanister(MPC)

Part2MPCFluidHandling(hydrostatictesting,blowdown,vacuumdrying,andheliumfilling)

Part3HITRAC/MPC&HISTORMStackupandMovingHISTORMtoISFSIPad Part4HITRAC/MPCplacedIn/OutofSpentFuelPoolandFuelloadinginMPCbasket(usingdummyfuel assembly)

Uponcompletionofthelicenseesinternaldryruns,anNRCobserveddryrunisconductedbythelicenseeto demonstratetheirproficiencyinthatgivenarea.OncetheNRCobserveddryruniscompletedforeachpart, thelicenseecanperformactualloadingoperations.TheNRChascompleteditsreviewsofPart1andPart2,as referencedabove.TheresultsofourreviewcanbefoundinNRCIntegratedInspectionReport 05000293/2014004andIndependentSpentFuelStorageReport07201044/2014002(ML14302A592).DryRuns Part3andPart4willbeconductedafterthelicenseehascompleteditsinternaldryruns.

2. Willthereactorremainoperatingduringthetestrun?

Yes.Dryrunactivitiesandactualdrycaskloadingoperationscanbeperformedwhiletheunitisonline.

3. InresponsetoNRCsRAI,whatexactlevelofseverityearthquakewaspostulatedbyEntergyisitsanalyses?

Theanswercannotbelabeledproprietarywithastraightface.SomeoftheinformationinAttachment11 perhapsisproprietarybutcertainlynottheinputabouttheseverityofseismiceventandthebasisforthat assumption.NRCowesthepublicthatinformation.

TheanalysisthatyouarereferringtoisHOLTECreportHI2104715,Revision7,SeismicAnalysisoftheLoaded HITRACintheSFPandSFPSlabQualification.Currentlythereportisclassifiedasproprietaryandnotavailable tothepublic.However,NRCstaffisworkingwithEntergyandHOLTECtogetanonproprietaryversionthatcan bemadeavailabletothepublic.DuringpreviousNRCinspections(NRCReport05000293/2014003and

2 07201044/2014002)theNRCreviewedthecranefactorytestprocedure,electricalcalculation,overheadcrane evaluationunderrevisedloads,andthecraneseismicanalysis.Itwasverifiedduringtheinspectionandthe NRCsreviewofEntergyslicenseamendmentrequest(LAR)thatthereactorbuildingcranemeetstheNUREG 0554andASMENOG1requirementsandisqualifiedtotheOperatingBasisEarthquake(OBE)andSafe ShutdownEarthquake(SSE).Thisequatestoahorizontalgroundaccelerationsof0.08g(OBE)and0.15g (SSE).Thecraneisdesignedtomeetthesitescurrentlicenseddesignbasisseismicevent.

From: Mary Lampert [1]

Sent: Wednesday, November 05, 2014 3:23 PM To: McKinley, Raymond; 'Meg Sheehan '

Cc: 'Pine duBois'; 'Richard Rothstein'; 'Rich Grassie'; 'ROSEMARY SMITH'; 'James Lampert'

Subject:

RE: Fwd: Scientist: Massive spikes in radioactivity are being hidden from public - Radiation doses around nuclear reactors increase exponentially - It's a major worry. very, very important - Something must be done (VIDEO)

HelloRay:

Thankyouforyourresponsesacoupleofadditionalquestionsandarecommendation.

Questions:

1. WhenisEntergydoingtheirtestrunforspentfueltransfer?
2. Willthereactorremainoperatingduringthetestrun?
3. InresponsetoNRCsRAI,whatexactlevelofseverityearthquakewaspostulatedbyEntergyisits analyses?Theanswercannotbelabeledproprietarywithastraightface.Someoftheinformation inAttachment11perhapsisproprietarybutcertainlynottheinputabouttheseverityofseismic eventandthebasisforthatassumption.NRCowesthepublicthatinformation.

Recommendation:

Thepublichasmanyquestionsregardingthetransfertodrycaskstorage.Infact,PilgrimCoalitionhas scheduledapublicforumDecember10.HoweveritwouldmakethemostsensefortheNRCtohostapublic forumthatdescribeswhatisgoingonandanswersquestionsfromthepublic.NRCStaffareuphere.Sucha meetingshouldtakeplaceASAP(notThanksgivingweek)anditwouldservethepublicandNRCperhaps betterthansimplyacitizenhostedforum.

Cheers,

Mary