NRC FORM 699...,. ** -. **.,

(03*2013) f~

i

~ ~~*

/

U.S. NUCLEAR REGULATORY COMMISSION CONVERSATION RECORD NAME OF PERSON(S) CONTACTED OR IN CONTACT VVITH YOU

!See below E-MAIL ADDRESS ORGANIZATION DOCKET NUMBER(S)

DATE OF CONTACT 11 /5/2014 TELEPHONE NUMBER (888) 447-9 153 Nuclear Regulatory Commission ( 1RC) 72-1040, 72-13, 50-313, 50-368 LICENSE NUMBER(S)

CONTROL NUMBER(S)

N/A SUBJECT Arkansas uclear One Request for Additional Information (RAI) Discussion

SUMMARY

Entergy (licensee):

tephenie Pyle, Bob Clark, A lan Palmer and Don Lomax Holtec: K im Manzione, Abrar Mohammed and Debu Mita-Majumdar NRC participants: Chris Allen. Jorge olis and Balwant ingal DATE OF SIGNATURE II /I 0/2014 TYPE OF CONVERSATION DE-MAIL 0 TELEPHONE D INCOMING 0 OUTGOING A copy of the RA ts were provided both to Entergy and to lloltec prior to the teleconference which commenced at approximately 2 P.

M. Eastern tandard Time. Entergy began the conversation by explaining that the purpose for providing the bulk water temperature in the 111-TRAC annulus was to show that the canister was in a stable condition. The RC acknowledged this, but emphasized that, because the fuel had been declared damaged, the canister was in a condition not analyzed in the Ill-TORM Final Safety Analysis Repon (F A R). Therefore, it was still necessary to provide information which showed that the analyses discussed in the F A R bounded the current cani tcr configuration. Consequently, Entergy committed to providing information which showed the current canister configuration was bounded by the F A R analyses.

Continue on Page 2 ACTION REQUIRED (IF ANY)

Continue on Page 3 NAME OF PERSON DOCUMENTING CONVERSATION Chris A llen SIGNATURE,

C'ff~

NRC FORM 699 (03*2013)

Page 1 of

NRC FORM 699 (03-2013)

SUMMARY

(Contmued from page 1)

U.S. NUCLEAR REGULATORY COMMISSION CONVERSATION RECORD (continued)

In discussing mou ehole blockage, lloltec stated that natural convection now within the basket was re tricted to the semi-circular ponion of the mou ehole a discussed in F A R Chapter I I.

R taffexpres ed confu ion ince F AR Chapter II discu sed accidents and off-normal conditions. l lowever, lloltec elaborated that the restricted now discussed in F A R Chapter I I was actually incorporated into the normal condition analyses of F 1\\R Chapter 4.

After discussion of the RA Is was complete, Entergy committed to providing a formal respon e to the information reque t early in the week of ovember 10. The call was concluded at approximately 2:30 P.M. Eastern tandard Time.

NRC FORM 699 (03-2013)

Page 2 of