FirstEnergy Nuclear Operating Company Eric A. Larson Site Vice President November 5, 2014 L-14-352 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

SUBJECT:

Beaver Valley Power Station, Unit No.2 Docket No. 50-412, License No. NPF-73 Beaver Valley Power Station P.O. Box 4 Shippingport, PA 15077 724-682-5234 Fax: 724-643-8069 Steam Generator Tube Inspection Report-Technical Specification 5.6.6.2 In accordance with Beaver Valley Power Station, Unit No. 2 Technical Specification 5.6.6.2, "Unit 2 SG Tube Inspection Report," FirstEnergy Nuclear Operating Company hereby submits the steam generator tube inspection results. The enclosed report provides information required by the technical specifications that was obtained during inspections conducted during the spring 2014 refueling outage.

There are no regulatory commitments contained in this submittal. If there are any questions or if additional information is required, please contact Mr. Thomas A. Lentz, Manager-Fleet Licensing, at (330) 315-6810.

Sincerely, Eric A. Larson

Enclosure:

Unit #2-2R17 Steam Generator 180 Day Report cc:

NRC Region I Administrator NRC Resident Inspector NRC Project Manager Director BRP/DEP Site BRP/DEP Representative

Enclosure L-14-352 Unit #2-2R17 Steam Generator 180 Day Report (69 Pages Follow)

FIRST ENERGY NUCLEAR OPERATING COMPANY Technical Services Engineering Department Nuclear Engineering Programs Section Beaver Valley Power Station Unit #2 - 2R17 Steam Generator 180 Day Report Reviewed by: Charles O'Neill Supervisor, Nuclear Approved by: Pat Pauvlinch & ~-t;;v /:r P. f"""*'"' Date:

Manager, Technical Services

Information Required by Technical Specification 5.6.6.2.1 Technical Specification (TS) 5.6.6.2.1 requires reporting of the following information after completion of an inspection performed in accordance with the Specification 5.5.5.2, Unit 2 Steam Generator (SG) Program. Information required by TS 5.6.6.2.1.a through TS 5.6.6.2.1.i is provided below for activities performed during the spring 2014 refueling outage (2R17).

Refer to the Definitions of Abbreviations, Codes and Reporting Terminology section (Page 8) of this report for abbreviations, codes and other nomenclature used throughout this report.

a) The scope of inspections performed on each SG:

Primary Side:

Bobbin Coil Probe 100% of the inservice tubes, full length (except Row 1 and 2 U-bends) per Generic Letter (GL) 95-05, "Voltage-Based Repair Criteria for Westinghouse Steam Generator Tubes Affected by Outside Diameter Stress Corrosion Cracking," dated August 3, 1995 1 00% of the hot leg sleeved tubes in Rows 3 & 4 from the top of the sleeve to the Blh TSP using a 0.630" wide groove probe Plus Point Probe 1 00% of Row 1 and 2 U-bend region 1 00% of the hot leg TTS from 6 inches above to 3 inches below the TTS NOTE 1 100% of TSP DSIIDNI indications with a bobbin coil voltage > 2.0 volts 100% of TSP mix residual signals~ 55° and ~ 1.25 volts 100% of TSP mix residual signals~ 2.0 volts 100% of dented hot and cold leg TSP intersections~ 5.0 volts 100% of dents~ 2.0 but< 5.0 volts at the 1st, 2"d, 3rd and 4th hot leg TSP's 1 00% of dents located at AVB intersections (+I-1 inch of AVB centerline) 1 00% of frees pan dings ~ 1 volt 1 00% of BLG and OXP signals in the hot leg tubesheet below the F* distance but above the tubesheet neutral axis 1 00% of BLG and OXP signals above the cold leg TTS 1 00% of bobbin "1-codes," such as frees pan differential signals meeting the change criteria (Change criteria: phase rotation > 10° and/or voltage amplitude > 0.5 volts) 1 00% of frees pan signals not resolved as MBMs or without a historical review 1 00% of Westinghouse Alloy 800 sleeves 25% of Row 3 through 8 U-bend region 25% of TSP mix residual signals > 1.5 volts but < 2.0 volts 20% of the cold leg TTS from 6 inches above to 3 inches below the TTS (SG B only) NOTE 1 Bounding of historical plugged tubes due to foreign object wear at the TTS and newly reported PLP signals NOTE 1 - For those tube locations where the expansion transition is located deeper into the tubesheet, the inspection distance into the tubesheet was adjusted to 5 inches below the top of the tubesheet to ensure adequate inspection coverage of the F* distance.

Page 2 of 9

Primary Side Visual Examinations There are 9 hot leg and 9 cold leg tube locations (SG A - 4; SG 8 - 2; SG C - 3) which contain Alloy 600 plugs repaired with the Westinghouse Plug-in-Plug (PIP) technique. These locations are visually examined each outage to assess the condition of the tack weld which holds the PIP in place. All PIP tack welds were determined to be acceptable.

  • A remote visual inspection of the area around the channel head drain line was performed in each hot and cold leg channelhead to meet the requirements of Westinghouse Nuclear Safety Advisory Letter 12-1, "Steam Generator Channel Head Degradation." Included in this examination was (a) the divider plate to stub runner weld, (b) the tubesheet to stub runner weld and (c) the divider plate to channelhead weld. This inspection looked for evidence of gross defects such as indications in welds, missing weld filler material, a breach in the weld metal, and unusual discoloration of the weld metal and/or cladding imperfections. All inspections were determined to be acceptable.

100% of tube plugs (as-found and as-left condition). As part of the routine steam generator inspection process, a visual examination is performed each time the primary side is opened to document the condition of the hot and cold leg channelheads. This process also includes tube plug accountability. During 2R17, as well as in all prior outages, the examinations verified that the correct number of tube plugs were present and in the proper tube locations. All plugs were determined to be acceptable.

Secondary Side:

A visual inspection of the secondary side tubesheet face, annulus and tube lane was performed during 2R17 in all 3 steam generators. No material was visually observed in any of the SG's that required retrieval.

For those tube locations where potential loose part indications were reported during the 2R 17 eddy current examinations (e.g., bobbin coil or Plus Point probes) and no visual inspection was performed at those particular tube locations, the Plus Point probe was used to verify that no degradation or tube wall wear was present. These tubes remained in service.

SG 8 & C steam drum - A visual inspection was conducted of the steam drum to assess the general condition of the internal components (e.g., accessible portions of the primary and secondary moisture separation equipment, risers, drain lines, welds, integrity of surrounding structures, feedwater header, J-nozzles, etc). The general condition of the steam drum was determined to be acceptable. Ultrasonic thickness measurements were taken at selected areas of the feedwater header in both SG's. No minimum wall conditions were reported.

b) Active degradation mechanisms found: NOTE 2 The following existing degradation mechanisms were reported during 2R17:

Axial ODSCC at non-dented TSP intersections Axial ODSCC in the hot leg sludge pile region Axial ODSCC at the hot leg TIS expansion transition region Axial PWSCC at the hot leg TIS expansion transition region Circumferential ODSCC at the hot leg TIS expansion transition region Axial ODSCC at > 5 volt freespan dings Wear at AV8 locations Volumetric indications associated with sleeved tubes NOTE 2 - Per the EPRI, "Steam Generator Management Program: Steam Generator Integrity Assessment Guidelines," Revision 3, the word "existing" is now used in lieu of the word "active" when describing degradation that has been previously and/or currently observed in the steam generators.

Page 3 of 9

c) Nondestructive examination techniques utilized for each degradation mechanism:

For the degradation mechanisms observed during 2R17, bobbin coil probes were used as the primary method of detection except at or below TTS and in Row 1 and 2 U-bends where bobbin probes are not qualified. In these areas, Plus Point probes were employed. Plus Point probes were also used to re-examine any ambiguous bobbin coil signals that were reported.

The 2R17 examination techniques were qualified, for detection and sizing (as applicable) of the existing and potential degradation mechanisms listed in the 2R17 degradation assessment, in accordance with Appendices Hand I of the EPRI, "Steam Generator Management Program:

Pressurized Water Reactor Steam Generator Examination Guidelines: Revision 7."

2R17 Examination Techniques Used for Degradation Detection/Sizing Degradation Mode Tube Location Probe EPRI ETSS*

Axial ODSCC H/L sludge pile, expansion transitions Bobbin 128413 3 Coil Plus Point 128424 Circumferential ODSCC H/L expansion transitions 3 Coil Plus Point 21410.1 Axial PWSCC H/L sludge pile, expansion transitions 3 Coil Plus Point 20511.1 Non-dented & dented H/L TSP's Bobbin 128411 Axial ODSCC 22401.1 (Bobbin< 5 volts, Plus Point~ 5 volts) 3 Coil Plus Point 128424 Axial ODSCC Freespan dings> 5 volts 3 Coil Plus Point 22401.1 Volumetric Top of tubesheet 3 Coil Plus Point 21998.1 Wear AVB locations Bobbin 96004.3 1 Coil Plus Point 21998.1

  • The applicable EPRI Examination Technique Specification Sheet (ETSS) is listed for reference only.

Site-specific ETSS's are developed prior to each steam generator inspection for each existing and potential degradation mechanism identified in the 2R 17 degradation assessment. The site-specific ETSS's are developed in accordance with Appendices H and I of the EPRI, "Steam Generator Management Program: Pressurized Water Reactor Steam Generator Examination Guidelines: Revision 7."

The examination techniques utilized during 2R 17 are considered "Site Validated" as defined in the EPRI, "Steam Generator Management Program: Pressurized Water Reactor Steam Generator Examination Guidelines: Revision 7," for each existing and potential degradation mechanism listed in the 2R17 degradation assessment.

Page 4 of 9

d) Location, orientation (if linear), and measured sizes (if available) of service-induced indications:

The 2R 17 Steam Generator Examination Results section of this report lists information that includes the location, orientation and measured sizes of service-induced indications. Further explanation of the information provided in these tables is given below:

1)

Bobbin probe indications reported as "1-codes" (i.e., DNI, DSI, DTI or NQI) were re-inspected with the Plus Point probe.

2)

Bobbin probe indications reported as PSI were re-inspected with the Plus Point probe. If the Plus Point probe indicated a possible TSP ligament breach existed (CSI), it was further evaluated by the original equipment manufacturer (OEM) engineering group. All ligament breach extents were found to be acceptable for continued plant operation.

3)

New AVB indications reported from the bobbin probe listed as PCT were inspected with the Plus Point probe. If the Plus Point probe indicated no crack-like flaws were present within the wear scar, a wear call (yi/AR) was assigned to the Plus Point report.

4)

Plus Point indications reported as "1-codes" (i.e., SAl, SCI, MAl or MCI) were either (a) removed from service via plugging, or (b) left in service if the indications qualified under the requirements of GL 95-05.

5)

All hot leg top of tubesheet circumferential indications were stabilized prior to plug installation.

e) Number of tubes plugged or repaired during the inspection outage for each active degradation mechanism:

The following tables list the number of tubes plugged for each existing degradation mechanism found during 2R17. This is the second consecutive outage where the alternate repair criteria of GL 95-05 was implemented. No sleeves were installed during 2R17.

For the following Tables:

The Hot Leg Sludge Pile column includes indications located above the top-of-tubesheet.

The Hot Leg Expansion Transition (Exp Trans) column includes indications located (a) at the secondary side face of the tubesheet, (b) at the expansion transition or (c) within the tubesheet.

2RCS-SG21A Degradation Hot Leg Hot Leg AVB Tubesheet Total Mode Sludge Pile Exp Trans Sleeves Indications Axial ODSCC 3

1 4

Circ ODSCC 1

18 19 Wear 1

1 Volumetric 2{1_1 2

Total 4

19 1

2 26 Notes for 2RCS-SG21A (26 indications in 26 tubes):

1) Two tubesheet sleeves were removed from service for having volumetric indications reported at approximately 2.0" above the TIS. Scrutiny of the indications could not definitively determine if the indications were located on the tube 10 or sleeve 00 however it was the best judgment of the analyst that the indications were located on the tube 10 surface. As a precautionary measure these two locations were removed from service by plugging. The parent tube between the sleeve joints is not considered part of the pressure boundary.

Page 5 of 9

2RCS-SG21B Degradation Hot Leg AVB Hot Leg Free Span Total Mode Exp Trans TSP Ding Indications Axial ODSCC 1 (1) 1 (2) 1 (3) 2 Axial PWSCC 1 (1) 1 Circ. ODSCC 6

6 Wear 2

2 Total 7

2 1

1 11 Notes for 2RCS-SG21 B: (12 indications in 11 tubes)

1) One tube contained an axial ODSCC and an axial PWSCC indication at the top-of-tubesheet.
2) One sleeved tube was removed from service for having a DSI reported at the 51h H/L TSP from a 0.630" diameter bobbin probe.
3) R25 C45 was in-situ pressure tested (SAl reported at AVB 1 +3.68") and successfully passed.

2RCS-SG21C Degradation Hot Leg Hot Leg Hot Leg Free Span Total Mode Sludge Pile Exp Trans TSP Ding Indications Axial ODSCC 2

1 2

5 Circ. ODSCC 10 10 Total 2

11 2 (1) 15 Notes for 2RCS-SG21C (15 indications in 15 tubes):

1) Two tubes were removed for metallurgical analysis per GL 95-05.

f) Total number and percentage of tubes plugged or repaired to date:

The total number of tubes plugged as of the end of 2R 17 is 785 tubes (7. 751% ). The equivalent plugging level due to Alloy 800 sleeves (installed in 2R16) is 789 tubes (7.790%).

g) The results of condition monitoring, including the results of tube pulls and in-situ testing:

All tubes were shown to satisfy the structural and leakage integrity performance criteria at 2R 17.

The relative severity levels of the degradation observed during 2R 17 were judged to be consistent with or bounded by the levels associated with previous outage inspection results. Based on the indications observed during 2R17, the SG tubing is expected to meet all operational structural and leakage integrity requirements at End-Of-Cycle 18. None of the indications reported during 2R 17 represented a leakage potential at postulated main steam line break conditions.

Two tubes (4 TSP intersections) were removed from the SG in support of GL 95-05. The preliminary metallurgical lab results were submitted to the NRC via FENOC Letter L-14-241, Enclosure C, and dated 08/11/14 During the 2R17 steam generator tube inspection, one indication (SG B: R25 C45; SAl at AVB1

+3.68") exceeded the structural integrity limits for axial degradation (i.e., burst integrity~ 3 times normal operating primary-to-secondary pressure differential across SG tubes) based on the calculation of burst pressure of the observed eddy current parameters. This tube was in situ pressure tested in a full tube mode to 5000 psi with no leakage or burst detected. All other eddy current indications satisfied the structural and leakage integrity performance criteria according to the guidance of the Steam Generator Integrity Assessment Guidelines: Revision 3.

Page 6 of9

h) The effective plugging percentage for all plugging and tube repairs in each SG:

The following table lists the plugging percentages and the effective plugging percentage due to sleeving for each steam generator as of the end of 2R 17.

SG Tubes Plugged Total Tubes Sleeves Plug

%Effective 2R17 Plugged Plugged Installed Equivalency Plugging 2RCS-SG21A 26 286 8.472 53 288 8.531 2RCS-SG21B 11 277 8.205 19 278 8.235 2RCS-SG21C 15 222 6.576 22 223 6.605 TOTALorAVG 52 785 7.751 94 _(_1) 789 7.790 (1) Represents the number of sleeves installed in 2R16 minus the three sleeves plugged 2R17 i) Repair method utilized and the number of tubes repaired by each repair method:

No sleeves were installed during 2R17.

Page 7 of 9

Definitions of Abbreviations, Codes, and Reporting Terminology 3 Letter Code Definitions I

Term I

Bobbin Coil Probe I

BLG Bulg_e DNI DenUDing with a Possible Indication DSI Distorted Tube Support Plate Signal with Possible Indication DTI Distorted Tubesheet Signal with Possible Indication MBM Manufacturing Burnish Mark NQI Non-Quantifiable Indication OXP Over Expansion PCT Percent Through Wall PSI Possible Tube Support Plate Indication (Ligament Breach)

Term Plus Point Probe CSI Confirmed Tube Support Plate Indication (Ligament Breach)

MAl Multiple Axial Indications MCI Multiple Circumferential Indications SAl Single Axial Indication SCI Single Circumferential Indication SVI Single Volumetric Indication VOL Volumetric Indication WAR Wear Additional Definitions Term Definition AVB Anti-Vibration Bar DENT Observed within a Tube Support Plate DING Observed in Free-Span Region of the Tubing EPRI Electric Power Research Institute H/L Hot Leg (Inlet)

NSAL Nuclear Safety Advisory Letter ODSCC Outside Diameter Stress Corrosion Cracking PLP Possible Loose Part PWSCC Primary Water Stress Corrosion Cracking TSP Tube SuQPort Plate TTS Top of Tubesheet Page 8 of 9

2R17 Steam Generator Examination Results Attachments A, B, and C provide steam generator examination results for tubes in the Beaver Valley Power Station, Unit No.2, Steam Generator A (2RCS-SG21A), Steam Generator B (2RCS-SG21 B), and Steam Generator C (2RCS-SG21 C) with service-induced indications.

NOTE: The data contained in the Attachments comes from the production analysis process and has not been re-sized or re-profiled for structural integrity concerns (i.e., field reported call is provided). Therefore, variations in the dimensions of a given indication (e.g., length, angular extent, voltage, etc.) may exist between this document and those documents previously submitted to the NRC in support of the spring 2014 outage (2R17).

Refer to the following tables for a description of terms used in these attachments.

Description of Column Headings and Data Abbreviations Used in Steam Generator Examination Results Report Header Definitions Term Definition ROW/COL Row & column designation of tube location IND Type of indication LOC Location of nearest support structure INCH Indication distance from nearest support structure

%TW Field measured percent through wall of an indication LENGTH Field measured length of an indication ANGLE Field measured angular extent of an indication around the tube VOLTS Field measured voltage amplitude of an indication PHASE Field measured angular rotation of an indication CHAN Recording channel of an indication FROM Starting point of examination TO End point of examination Examination Extent Definitions (FROM - TO)

Term Definition 01C 1st Tube Support Plate on Cold Leg Side 01H 1st Tube Support Plate on Hot Leg Side AVB1 1st Anti-Vibration Bar (Numbered Hot Leg to Cold Leg)

SBH Bottom of Sleeve - Hot Leg STH Top of Sleeve - Hot leg TEC Tube End - Cold Leg TEH Tube End - Hot Leg TSC Cold Leg Tubesheet (Secondary Face)

TSH Hot Leg Tubesheet (Secondary Face)

Page 9 of 9

Attachment A BEAVER VALLEY UNIT #2 2R17 SG EXAMINATION RESULTS 2RCS-S 21A TUBES WITH SERVICE INDUCED INDICATIONS

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 1

2 2

2 2

2 2

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 68 DNI 08C 0.07 32 DNI 03C

-0.25 69 NQI 02C 46.82 87 DNI OSH 0.01 88 DSI 02H 0.00 88 DNI 06H 0.00 92 DSI 03H

-0.20 15 DSI 03H 0.07 23 DNI 07C

-0.10 26 DNI 03H 0.12 59 DSI 02H 0.16 64 DNI 04H 0.00 65 DSI 07H 0.00 71 DNI 08H

-0.01 77 DNI 08H 0.00 79 DSI 07H

-0.18 81 DNI 08C 0.02 81 DSI 03H 0.01 81 DNI 07H 0.01 84 DSI 03H 0.00 85 DSI 04H 0.07 86 DNI 07H 0.00 88 DNI 07H 0.00 89 DNI 06H 0.00 91 DNI 04H

-0.12 92 DSI 02H

-0.13 9

DNI 07C 0.00 9

DSI 03H

-0.01 9

DSI 04H 0.13 9

DNI 08H

-0.06 18 DSI OSH 0.00 21 DSI 03H 0.00 22 DNI 07H 0.13 24 DSI 02H

-0.07 26 DSI 02H

-0.01 26 DNI 04H

-0.16 34 DSI 03H

-0.29 34 DNI 08H

-0.01 39 DSI 02H 0.01 50 DSI 02H 0.10 50 DSI 03H

-0.09 50 DSI 04H

-0.03 Page 1 of 23 1.67 20 P1 1.30 10 P1 0.23 106 3

1.71 48 P1 0.28 105

. P1 1.68 43 P1 0.41 94 P1 0.75 95 P1 1.33 42 P1 1.60 46 P1 0.61 49 P1 1.28 56 P1 0.52 74 P1 1.29 42 P1 1.28 39 P1 0.45 125 P1 1.41 44 0.93 104 1.52 52 0.56 64 0.71 58 1.36 54 1.36 42 1.30 48 1.39 28 0.28 119 1.57 46 0.86 73 0.51 59 1.30 38 0.56 27 0.62 80 1.45 38 0.38 63 0.35 68 1.37 45 0.24 96 1.42 45 0.31 84 0.87 48 0.77 39 0.51 33 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 08C TEC 08C TEC 08C TEC 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08C TEC 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08C TEC 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08C TEC 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL JND DNI DSI LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO TEC TEH 4

54 08C

-0.02 02H

-0.06 4

54 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 54 DNI 03H 0.00 54 DSI 04H

-0.04 54 DSI 05H 0.00 60 DSI 02H 0.01 60 DSI 06H

-0.01 62 DNI 02H 0.01 62 DNI 03H 0.00 62 DNI 05H 0.12 63 DSI 02H

-0.18 67 DNI 02H

-0.01 67 DNI 03H 0.00 72 DNI 05H 0.01 72 DNI 08H 0.01 73 DNI 07H 0.00 78 DSI 05H 0.04 79 DNI 06H 0.01 80 DNI 05H 0.01 85 DSI 08C 0.00 10 DSI 02H 0.12 10 DSI 03H 0.00 10 DSI 04H 0.15 11 DSI 04H 0.02 12 DNI 08H 0.00 13 DNI 06H

-0.03 23 SCI TSH

-0.09 23 DSI 02H 0.00 23 DNI 06H 0.02 25 DSI 05H 0.07 25 DNI 06H 0.00 25 DNI 08H 0.00 25 DNI 06C 0.00 26 DSI 02H 0.04 26 DSI 03H

-0.01 26 DNI 07C 0.00 28 DNI 04H 0.00 29 DSI 02H 0.02 29 MAl 02H

-0.05 30 DSI 03H 0.00 53 DSI 02H 0.02 71 DNI 07C 0.00 1.46 0.42 1.93 46 46 55 0.43 56 0.56 79 0.18 121 0.42 43 1.67 46 1.91 36 1.43 32 0.50 74 1.48 55 1.25 56 1.31 53 1.49 48 1.31 57 0.40 27 1.25 52 1.30 55 0.26 46 1.27 64 0.44 109 0.46 76 0.64 38 1.28 1.55 39 22 0.28" 162° 0.35 109 0.33 74 1.28 40 0.60 103 1.77 40 1.22 51 1.62 38 0.62 123 0.73 75 1.29 1.42 57 39 0.89 100 0.32" 45° 0.20 44 Page 2 of 23 0.57 20 0.21 1.43 57 46 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl 6

Pl Pl Pl 08C 08H 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08C TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 08H TEH TSH TSH TEH TEC TEH TEC 08H TEH 08H TEH 08H TEH 08C TEC 08H TEH 08H TEH 08C TEC 08H TEH TEH TEC 02H 02H 08H TEH TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21A

{TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL 5

71 IND LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 5

5 5

5 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

DNI 08H 0.10 1.76 46 Pl TEH TEC 77 DNI 04H 0.10 79 DNI 06H 0.02 80 DSI 05H 0.22 82 DSI 03H 0.17 6

DNI 08H 0.10 11 DNI 06H 0.00 12 DNI 07H 0.02 15 DSI 02H 0.10 15 DNI 08H 0.00 17 DNI 04H 0.25 20 DNI 08H 0.00 27 DSI 06H 0.00 27 DNI 07H 0.13 32 DSI 02H

-0.02 34 DSI 02H 0.10 34 DNI 08H 0.08 35 DSI 02H

-0.15 35 DSI 03H

-0.02 35 DSI OSH

-0.10 40 DSI 03H 0.05 40 DSI 04H 0.10 41 DSI 08H 0.12 41 SAl 08H

-0.10 43 DSI 02H 0.05 63 DNI 08H 0.13 4

DNI 06H 0.00 4

DNI 07H 0.12 6

6 DNI 04H

-0.07 DNI OSH

-0.02 14 DSI 03H 0.00 18 DSI 03H 0.05 18 DSI 05H 0.02 19 DSI 03H 0.12 27 DSI 05H 0.10 31 DNI 07C

-0.22 45 SCI TSH

-0.10 47 DNI 04H

-0.05 49 DSI 02H 0.00 49 DNI 05H 0.00 51 DSI 02H 0.20 57 DNI 02H

-0.14 1.27 44 1.29 57 0.18 48 0.39 112 1.29 41 1.54 42 1.29 46 0.28 109 1.31 43 1.30 54 1.36 44 0.33 73 2.19 39 0.19 134 0.29 145 1.37 53 1.09 99 0.77 86 0.35 82 0.25 102 0.12 77 0.25 132 0.34" 42° 0.13 79 60 36 56 50 53 43 0.61 1.38 1.46 1.35 1.80 1.26 0.29 42 0.59 96 0.24 124 0.30 66 0.39 151 1.64 31 0.17" 309° 0.27 59 11 1.77 0.22 106 1.30 24 0.58 43 1.52 40 Page 3 of 23 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl 6

Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 08H 08H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS}

ROW COL IND LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 7

57 DNI 05H 0.07 1.74 35 P1 TEH TEC 7

7 7

7 7

7 7

7 7

7 7

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

57 DNI 07H 0.00 58 DSI 03H 0.02 61 SCI TSH

-0.05 69 DNI 03H 0.07 71 DSI 03H

-0.02 82 DNI 07C

-0.10 83 DNI 08H 0.18 86 DNI 08C

-0.10 87 DNI 07H

-0.02 87 DNI 08H 0.15 94 DSI 02H

-0.02 2

DNI 05H 0.10 19 DSI 02H 0.05 19 DNI 03H

-0.12 22 SCI TSH

-0.09 28 DSI 02H 0.05 28 DNI 07H 0.15 28 DNI 08H 0.13 29 DSI 02H 0.10 32 DSI 03H

-0.10 32 DNI 05H 0.20 32 DNI 07H 0.25 32 DNI 08H 0.10 34 DSI 03H

-0.15 42 DSI 02H 0.12 52 DNI 07H 0.17 56 DNI 03H 0.02 56 DNI 07H 0.32 56 DNI 08H 0.16 61 DNI 04H

-0.07 65 DNI 07C

-0.02 65 DNI 07H

-0.02 66 DNI 06H 0.10 66 DNI 08H

-0.07 68 DNI 08C

-0.02 69 DSI 02H 0.00 69 DNI 04H 0.07 69 DNI 05H

-0.02 69 DNI 08H

-0.05 74 DNI 03H 0.00 74 DNI 04H 0.00 0.10" 0.15" 1.46 33 0.26 116 27° 0.15 61 1.30 42 0.49 61 1.35 51 1.42 53 1.28 45 1.41 52 1.37 54 0.31 145 1.39 52 0.55 91 1.26 71° 0.13 0.32 1.25 1.35 0.28 0.29 1.59 1.51 1.72 1.07 37 80 66 53 40 65 97 25 19 31 49 0.34 102 1.16 33 1.33 44 1.29 1.30 1.13 1.47 1.58 1.39 1.44 1.25 0.24 1.36 1.26 1.25 1.54 1.64 32 43 28 40 47 40 49 42 91 50 55 58 49 56 Page 4 of 23 P1 P1 P2 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND DNI DNI DNI DSI LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO TEC TEC TEC TEC 8

74 06H

-0.05 1.26 49 Pl TEH 8

74 07H

-0.02 08H

-0.07 05H 0.02 8

74 8

76 8

8 9

9 9

9 85 DSI 02H 0.02 91 DSI 04H 0.05 7

DNI 04H 0.15 10 DSI 02H

-0.12 13 DSI 02H 0.00 14 DSI 03H 0.02 9

16 DSI 02H 0.05 9

16 DSI 03H 0.02 9

  • 16 DSI 04H 0.07 9

22 SCI TSH

-0.06 9

22 DSI 03H

-0.02 9

27 DNI 03H

-0.10 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 28 DNI 07H 0.00 28 DNI 08C

-0.10 33 DNI 07C

-0.10 33 DNI 08H 0.08 34 DSI 02H 0.20 34 SAl 02H

-0.28 35 DSI 02H 0.02 37 DNI 04H

-0.05 37 DNI 05H 0.00 37 DNI 06H

-0.12 37 DNI 08H 0.00 38 DSI 05H 0.30 39 SCI TSH 0.00 40 DSI 03H 0.00 42 DNI 04H

-0.12 49 DNI 04H

-0.12 49 DNI 08H 0.13 51 DSI 04H 0.00 51 SAl 04H

-0.13 56 DSI 02H 0.17 56 DSI 04H 0.20 57 DSI 02H 0.02 57 DSI 03H

-0.07 65 DNI 06H 0.20 69 DNI 06H 0.27 74 DSI 03H 0.00 1.69 1.46 0.36 0.20 0.45 1.40 0.77 0.83 0.27 38 42 42 22 68 39 84 58 49 0.56 103 0.93 53 0.45 131 0.28" 190° 0.20 90 0.14" 0.38 80 1.37 47 1.36 1.45 1.39 54 44 35 1.51 29 0.24 121 0.14 156 0.54 130 2.01 21 1.36 24 1.83 1.85 0.87 0.17" 84° 0.08 22 27 89 89 86 34 53 42 27 81 72 0.15" Page 5 of 23 0.39 1.61 1.25 1.58 0.41 0.10 0.61 0.30 53 0.20 129 0.52 54 1.27 53 1.44 0.19 17 61 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl 6

Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl 2

Pl Pl Pl Pl Pl Pl Pl TEH TEH TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 02H 02H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC STH TEC 04H 04H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS}

ROW COL IND DNI DNI LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 9

85 08C

-0.18 1.19 44 P1 TEH TEC 10 2

03H 0.00 1.54 55 P1 TEH TEC 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 4

7 7

DNI 06H 0.00 DSI 02H 0.12 DSI 03H 0.17 7

DNI 06H 0.15 8

DSI 03H

-0.05 12 DNI 06H 0.00 12 DNI 07H 0.00 15 DNI 07H 0.00 19 DSI 04H

-0.02 22 DNI 05H 0.02 26 DSI 04H 0.05 29 DNI 07H

-0.12 37 DSI 03H 0.05 41 SCI TSH

-0.15 47 DNI 02H

-0.07 47 DNI 04H 0.07 47 DNI 05H 0.02 47 DNI 06H 0.05 47 DNI 07H

-0.12 49 DNI 07C

-0.02 49 DNI 08C

-0.05 49 DNI 08H 0.02 51 DNI 04H

-0.05 57 DNI 02H

-0.07 57 DNI 03H 0.34 57 DNI 04H 0.15 57 DNI 05H 0.12 57 DNI 06H 0.05 57 DNI 07H 0.15 57 DNI 08C

-0.02 57 DNI 08H 0.02 58 DNI 07C 0.15 58 DNI 08C

-0.18 64 DNI 02H

-0.02 64 DNI 03H

-0.05 64 DNI 07H 0.07 70 DNI 07H 0.00 72 DNI 07H

-0.17 75 DNI 05H 0.00 75 DNI 08H 0.05 1.32 0.83 0.27 1.47 0.59 1.27 1.27 1.29 57 49 98 50 69 50 50 51 0.32 69 1.38 57 0.33 84 1.84 23 0.33 126 0.20" 96° 0.14 105 Page 6 of 23 1.37 1.26 1.39 1.56 1.46 1.63 1.40 1.08 1.08 1.65 1.31 1.43 1.95 1.35 1.83 1.11 1.36 1.83 1.22 1.98 1.34 1.46 1.30 1.64 1.51 1.55 37 53 37 27 21 38 35 36 19 24 32 40 24 24 35 31 29 16 42 10 28 23 39 14 54 28 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 10 10 11 11 11 89 DNI 06H 0.10 89 DNI 07H 0.08 2

DSI 03H 0.02 3

DNI 04H 0.00 8

DNI 08C

-0.25 11 24 DNI 04H 0.10 11 29 DNI 05H 0.00 11 29 DNI 06H 0.02 11 42 DNI 07H 0.02 11 48 DSI 02H 0.10 11 48 DNI 06H 0.05 11 48 DNI 07H 0.05 11 48 DSI 08H 0.06 11 77 DNI 03H 0.12 11 77 DSI 05H 0.02 11 11 12 12 12 12 12 12 12 12 78 DSI 06H

-0.05 80 DNI 06H 0.30 3

DNI 07H

-0.02 20 DNI 05H 0.02 26 DNI 05H 0.02 27 DNI 05H 0.17 34 DSI 02H 0.10 34 DNI 06H 0.05 48 DSI 05H 0.05 58 DNI 04H 0.12 12 64 DNI 02H 0.15 12 64 DNI 04H

-0.05 12 64 DNI 05H 0.10 12 64 DNI 07H 0.00 12 64 DNI 08C

-0.05 12 64 DNI 08H 0.00 12 67 DNI 05H 0.00 12 67 DNI 06H 0.00 12 67 DNI 08C 0.00 12 69 DSI 03H

-0.07 12 69 DNI 08C

-0.02 12 70 DSI 03H

-0.05 12 71 DNI 06C 0.05 12 71 DNI 07C

-0.02 12 71 DNI 07H 0.00 12 71 DNI 08H

-0.07 12 72 DSI 02H

-0.07 Page 7 of 23 2.19 1.66 0.97 2.45 1.44 1.33 1.62 1.75 1.65 0.92 1.93 2.27 0.40 1.31 0.67 0.22 1.63 1.57 1.50 1.68 1.59 0.44 1.91 0.56 1.04 38 53 83 49 14 39 18 13 26 37 46 47 42 56 51 28 16 11 46 11 27 81 39 28 54 1.38 45 1.86 51 1.41 41 1.80 47 1.50 40 1.53 44 1.37 54 1.67 53 1.43 41 0.34 63 1.34 36 0.46 109 2.04 30 1.41 38 1.45 48 2.11 29 0.30 123 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS}

ROW COL IND DNI LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 12 72 03H 0.02 1.27 72 P1 TEH TEC 12 72 DNI OSH 0.02 12 72 DNI 08H

-0.05 12 73 DSI OSH 0.07 12 73 DNI 06H

-0.02 12 73 DNI 07H

-0.05 12 73 DNI 08C 0.03 12 73 DNI 08H 0.00 12 74 DSI 02H

-0.05 12 74 DSI 03H

-0.12 12 74 DNI 07H

-0.02 12 74 DNI 08H

-0.03 12 75 DNI 02H 0.12 12 75 DNI 03H 0.00 12 75 DNI OSH 0.12 12 75 DNI 06H

-0.07 12 78 DNI 06C 0.12 12 89 DNI 04H

-0.10 12 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 89 DNI 06H 0.02 4

DNI 03H 0.02 22 DNI 07H 0.02 32 DSI 02H 0.07 39 DSI OSH 0.12 39 DNI 08H 0.00 41 DNI 03H 0.00 41 DNI 07C 0.00 41 DNI 07H 0.00 49 DSI 04H 0.05 60 DSI 02H

-0.17 67 DNI OSC 0.00 67 DSI 06C

-0.05 71 DSI 04H 0.02 80 DSI 03H 0.02 80 DNI 08H 0.00 83 DNI 06H 0.00 83 DNI 07H 0.00 84 DSI 02H 0.02 85 DSI 02H 0.02 85 DNI 07C 0.00 85 DNI 08C 0.00 86 DSI 03H 0.02 86 DNI 07H 0.00 Page 8 of 23 1.73 49 1.86 38 0.17 86 1.59 47 1.96 39 1.47 37 1.33 45 0.40 144 0.49 33 1.74 42 1.58 43 1.34 38 1.86 46 2.00 28 1.64 36 1.46 28 1.39 55 1.33 1.80 1.74 0.15 0.38 55 52 54 51 90 1.28 37 1.29 30 1.29 23 1.54 21 0.21 38 0.26 157 1.25 so 0.33 54 0.48 13 0.32 89 1.39 48 1.84 so 2.02 0.58 0.57 1.93 1.64 0.34 1.71 45 63 59 33 37 82 49 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND DNI LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 13 86 08H 0.00 1.77 45 P1 TEH TEC 13 13 13 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 87 DNI 08C 0.00 91 DSI 05H 0.07 92 DSI 04H 0.05 4

DNI 02H

-0.07 15 DNI 03H 0.20 15 DSI 04H

-0.05 20 DSI 03H 0.10 20 DNI 06H 0.00 20 DNI 08C

-0.20 21 DNI 07H 0.00 24 DNI 06H 0.02 24 DNI 07H 0.00 25 DSI 05H 0.05 27 DSI 05H 0.25 31 DSI 02H 0.02 39 DNI 06H 0.00 40 DSI 05H 0.10 40 SAl 05H

-0.09 14 42 DNI 02H 0.02 14 43 DNI 06H 0.00 14 48 DSI 05H 0.02 14 49 DNI 05C 0.00 14 49 DNI 06C 0.02 14 49 DNI 06H 0.12 14 49 DNI 07C 0.00 14 49 DNI 08C 0.05 14 49 DNI 08H 0.14 14 50 DSI 03H

-0.07 14 50 DNI 08H

-0.02 14 53 DSI 02H

-0.05 14 53 DNI 06H 0.17 14 53 DNI 07H 0.12 14 14 14 14 14 14 14 14 14 54 DSI 02H 0.05 54 DNI 06H 0.17 54 DNI 07H 0.12 55 DNI 05H 0.02 55 DNI 06H

-0.27 58 DSI 02H 0.00 58 DNI 06C

-0.02 58 DNI 07C 0.00 58 DNI 08H 0.13 0.17" Page 9 of 23 1.98 35 0.35 105 0.52 101 1.25 17 1.69 18 0.33 83 0.45 1.37 1.39 1.43 55 42 34 34 1.36 45 1.38 38 0.30 93 0.33 150 0.21 1.31 0.42 0.14 11 46 12 81 1.73 45 1.29 29 0.26 118 1.48 36 1.27 1.21 1.35 1.40 1.44 0.27 1.41 0.14 1.18 1.19 0.28 1.68 1.30 1.12 1.69 40 55 40 36 46 89 48 79 24 28 50 48 45 29 11 0.30 142 1.63 1.27 1.35 32 45 47 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 6

P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 05H 05H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS}

ROW COL IND LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 14 59 DSI 02H

-0.02 0.30 106 P1 TEH TEC 14 59 DSI 03H

-0.02 0.35 61 P1 TEH TEC 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 59 DNI 04H 0.15 59 DSI 06H 0.05 59 DNI 07C

-0.02 59 DNI 08C

-0.02 59 DNI 08H 0.10 60 DNI 08H 0.14 61 DNI 06H

-0.05 61 DNI 08H

-0.02 63 DNI 04H

-0.05 64 DNI 64 DNI 65 ' DNI 65 DSI 65 DNI 03H 0.00 04H

-0.02 02H

-0.05 03H

-0.12 08H

-0.07 66 DNI 06H 0.00 66 DNI 07H

-0.02 66 DNI 08H

-0.10 67 DNI 07H

-0.02 68 DSI 02H 0.05 14 70 DSI 03H

-0.07 14 70 DNI 06H 0.02 14 70 DNI 07H

-0.02 14 71 DNI 03H

-0.02 14 71 DNI 08H

-0.02 14 73 DNI 06H 0.12 14 73 DNI 07H

-0.02 14 74 DNI 03H 0.02 14 74 DNI 05H 0.02 14 75 DNI 07H 0.00 14 77 DNI 07C

-0.02 14 77 DNI 08C

-0.10 14 77 DNI 08H 0.00 14 14 15 15 15 15 15 15 80 DSI 03H 0.00 86 DSI 04H 0.07 27 DSI 05H 0.05 35 DNI 06H 0.00 50 DNI 03H

-0.22 63 DSI 02H 0.05 63 DNI 06H

-0.02 65 DNI 03H

-0.02 Page 10 of 23 1.40 48 0.50 133 1.40 1.66 1.81 1.49 1.75 1.67 1.75 1.51 2.15 3.08 0.30 1.45 1.39 1.33 1.64 1.52 0.41 43 34 38 51 47 38 59 75 54 43 80 49 51 56 41 48 43 0.63 135 1.45 54 1.65 42 1.34 50 1.43 42 1.96 31 2.08 36 1.28 55 1.53 49 1.27 46 1.54 52 1.37 47 1.44 49 0.25 0.56 0.25 1.61 1.34 0.53 1.80 1.63 86 27 72 57 40 84 46 47 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS}

ROW COL IND LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 15 67 DSI 02H 0.00 0.63 18 P1 TEH TEC 15 70 DNI 03H 0.00 15 71 DSI 02H 0.02 15 72 DSI 02H 0.00 15 73 DSI OSH 0.05 15 73 DNI 06C 0.00 15 74 DSI 03H 0.07 15 74 DNI OSH 0.39 15 75 DSI 02H 0.02 15 75 DNI 07C 0.00 15 75 DSI 08H 0.14 15 15 15 75 SAl 08H 0.02 80 DNI 02H 0.00 80 DNI 04H 0.00 15 80 DNI OSH 0.00 15 80 DNI 07H 0.00 15 80 DNI 08H 0.00 15 82 DNI 06H 0.02 15 82 DNI 07H 0.00 15 82 DNI 08H 0.00 15 85 DNI 03H 0.00 15 85 DNI 06H 0.00 15 85 DNI 07C 0.00 15 85 DNI 08C 0.00 15 15 15 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 85 SVI TSH 1.72 85 SVI TSH 2.04 90 DNI 08H 0.00 11 DSI OSH

-0.07 11 SAl OSH

-0.11 22 SCI TSH

-0.15 38 DNI 07C

-0.10 44 DNI 04H 0.07 51 DNI 03H 0.15 52 DSI 02H

-0.07 52 DNI 07H 0.05 53 DSI 03H 0.02 54 DNI 08H 0.10 55 DNI 03H

-0.02 55 DNI 04H 0.02 55 DNI 07H

-0.07 56 DNI 07H 0.15 57 DNI 04H 0.02 0.33" 0.32" 0.26" 0.17".

1.64 57 0.36 49 0.35 65 0.32 75 1.33 57 0.89 44 1.64 52 0.36 102 1.89 43 0.21 151 29° 0.09 132 2.02 54 2.09 so 1.94 1.77 1.86 1.32 1.47 1.26 2.28 2.61 2.02 1.88 71° 0.73 48° 0.40 1.25 0.27 0.12 0.20" 130° 0.08 49 48 42 57 53 56 34 33 31 27 72 84 55 48 79 64 Page 11 of 23 1.92 15 1.32 47 1.41 55 0.78 140 1.58 0.36 1.36 1.49 1.66 1.16 1.71 1.45 32 29 so 22 18 8

40 45 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 6

P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 3

3 P1 P1 6

P2 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 08H 08H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC STH TEC STH TEC STH TEC STH TEC SBH STH SBH STH TEH TEC TEH TEC OSH 06H TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS}

ROW COL IND LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 16 57 DNI 06H 0.12 1.66 49 P1 TEH TEC 16 57 DNI 08C

-0.09 16 57 DNI 08H 0.10 16 59 DNI 02H 0.07 16 59 DNI 03H

-0.10 16 59 DSI 04H

-0.07 16 59 DNI 07H 0.15 16 62 DSI 08H

-0.12 16 63 DNI 05H 0.07 16 66 DSI 03H

-0.07 16 70 DSI 03H

-0.05 16 16 16 16 16 16 16 16 16 16 16 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 70 DNI 07H 0.00 70 DNI 08H 0.00 72 DSI 02H

-0.07 72 DNI 05H

-0.02 72 DNI 06H 0.02 72 DNI 07H 0.00 76 DSI 02H 0.02 77 DSI 05H 0.00 84 DNI 06H 0.02 84 DNI 07H 0.00 84 DNI 08H 0.00 6

DNI 02H 0.19 10 DSI 03H

-0.05 27 DSI 04H 0.00 31 DNI 04H 0.00 32 DSI 05H 0.02 35 DNI 06H 0.10 39 DNI 05H 0.00 46 DSI 02H 0.00 46 DNI 03H 0.00 46 DNI 04H 0.00 48 SCI TSH 0.00 49 DNI 08H 0.00 53 DNI 08C

-0.02 54 DNI 06C 0.12 54 DNI 07C 0.00 55 DNI 03H 0.07 59 DSI 02H 0.19 59 DSI 05H 0.27 76 DNI 02H 0.32 76 DNI 03H 0.05 1.58 40 2.09 36 1.49 33 2.10 54 0.96 63 1.69 43 0.17 119 1.44 46 0.33 33 0.22 68 1.43 1.37 0.14 2.01 1.34 1.37 0.46 0.13 1.34 1.62 1.26 51 48 95 41 51 48 91 99 51 44 54 1.45 19 0.30 152 0.37 1.49 0.48 1.38 1.72 0.62 1.57 54 16 31 53 18 19 26 1.40 22 0.29" 47° 0.14 121 Page 12 of 23 1.27 39 1.71 1.83 46 19 1.94 39 1.28 51 0.28 122 0.14 90 1.42 48 1.62 46 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 P1 P1 P1 P1 P1 P1 P1 P1 P1 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS}

ROW COL INO DSI DSI DSI LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO TEC TEC TEC 17 81 03H

-0.05 04H

-0.07 04H 0.05 17 81 18 7

18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 10 DSI 03H 0.12 10 DSI 04H 0.02 10 DNI 08C 0.00 15 DNI 08H

-0.18 27 DSI 07H

-0.02 43 DNI OSH 0.10 43 DNI 07H 0.00 47 DSI 02H 0.02 47 DSI OSH 0.05 48 DNI 07H 0.17 48 DNI 08H 0.03 52 DNI 03H 0.20 52 DNI OSC 0.00 52 DNI 06C

-0.02 55 DNI OSH

-0.10 55 DNI 06C 0.02 55 DNI 06H 0.12 55 DNI 07C 0.05 18 55 DNI 07H

-0.07 18 55 DNI 08C

-0.07 18 56 DNI 07H 0.20 18 56 DNI 08H 0.00 18 57 DSI 02H

-0.02 18 57 DNI 03H

-0.10 18 57 DNI 04H 0.20 18 57 DNI 05H

-0.02 18 57 DNI 06H 0.12 18 57 DNI 07H 0.12 18 57 DNI 08H

-0.12 18 18 18 18 18 18 19 19 19 19 58 DNI 04H 0.00 64 DNI 07H 0.00 66 DNI 05H 0.00 71 DNI OSC 0.00 71 DNI 08H 0.00 88 DSI OSH 0.00 7

DSI 02H 0.00 8

DSI 03H

-0.07 13 DNI 04H 0.25 15 DSI 03H

-0.05 Page 13 of 23 0.21 0.28 0.16 98 33 96 0.66 168 0.20 82 1.25 37 1.85 0.23 1.32 1.46 0.25 0.80 1.88 1.82 1.77 2.13 2.15 2.18 1.46 1.62 1.46 1.20 1.42 1.38 1.30 0.70 1.21 1.62 1.69 1.69 1.79 1.57 1.27 1.29 1.30 1.34 1.38 18 24 51 37 43 52 28 57 41 22 26 48 30 so 34 48 32 53 47 59 55 50 45 54 46 42 52 34 36 26 39 0.43 33 0.68 46 0.22 94 1.42 18 0.24 130 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 TEH TEH TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 19 15 DSI 04H

-0.02 0.21 121 P1 TEH TEC 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 54 DNI 03H 0.22 56 DSI 03H

-0.32 56 DNI 04H

-0.07 56 DNI 06H 0.12 56 DNI 07H 0.17 56 DNI 08H 0.04 57 DSI 02H 0.02 57 DSI 04H

-0.02 57 DNI 08H 0.11 59 DNI 02H 0.02 59 DNI 03H 0.02 59 DNI 04H 0.07 59 DNI OSC 0.34 59 DNI OSH

-0.27 60 DSI 02H 0.22 60 DNI 03H

-0.05 9

DSI 03H 0.02 10 DNI 03H 0.17 10 DSI 04H

-0.02 12 DSI 02H 0.10 15 DNI 07H 0.18 22 DSI 02H 0.07 22 DSI 03H 0.15 22 DSI 08H 0.00 24 DNI 06H 0.27 25 DNI 07H 0.00 40 DNI 04H

-0.10 43 DNI 06H 0.00 50 DNI 06H 0.00 57 DSI 02H 0.19 57 DNI 06C

-0.07 57 DNI 07C 0.17 58 DNI 08C 0.05 60 DNI 07H

-0.02 60 DNI 08H 0.00 61 DNI OSH

-0.05 61 DNI 06H 0.00 61 DNI 07H 0.00 61 DNI 08H 0.00 62 DSI OSH

-0.17 64 DNI OSH 0.02 Page 14 of 23 1.09 0.28 1.03 28 63 46 1.44 52 1.36 49 1.25 13 0.52 157 0.16 1.47 2.65 2.42 3.20 2.62 87 47 54 43 38 13 2.39 12 0.42 40 1.58 so 0.37 122 1.31 53 0.23 71 0.29 49 1.34 40 0.50 120 0.29 70 0.39 33 1.64 16 1.29 45 1.36 1.28 1.28 0.14 2.15 1.38 1.41 1.25 1.29 1.43 1.60 1.39 1.79 22 53 34 62 21 48 32 47 45 56 49 46 36 0.43 129 1.25 42 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21A

{TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO DNI PCT LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO TEC TEC 20 64 07H 0.00 1.39 38 P1 TEH 20 64 AV1 0.00 18%

20 20 20 20 20 20 20 20 20 20 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 64 PCT AV2 0.00 18%

64 PCT AV3 0.00 16%

70 DNI 07H 0.00 71 DNI 08H 0.00 72 DNI 08H 0.00 75 DSI 05H

-0.10 78 DSI 04H 0.05 78 DNI 08H 0.00 85 DSI 03H 0.02 89 DNI 06H 0.00 12 DNI 07H 0.00 13 DNI 05H 0.15 18 DSI 04H

-0.02 21 DNI OSH 0.07 25 DSI 03H 0.15 26 DSI OSH 0.12 34 DSI 02H 0.10 43 DSI 02H 0.07 45 DNI 07H 0.00 46 DSI 02H

-0.05 48 DNI 02H 0.07 48 DNI 03H

-0.05 48 DNI 04H

-0.15 48 DNI OSH 0.07 48 DNI 06H 0.02 48 DNI 07H 0.10 48 DNI 08H 0.03 SO DNI 03H 0.07 51 DNI 03H 0.00 51 DNI 06H 0.17 53 DNI 08H

-0.10 54 DNI 03H

-0.10 54 DNI 04H 0.00 54 DNI OSH 0.15 55 DSI 02H

-0.02 56 DNI 04H 0.12 72 DSI 03H 0.17 73 DNI 02C

-0.05 73 DSI 03H

-0.07 73 DNI 08C 0.00 Page 15 of 23 1.13 1.11 0.96 1.27 1.27 1.45 0

0 0

44 42 41 0.11 113 0.19 114 1.31 46 0.26 43 1.26 47 1.73 55 1.28 41 0.43 163 1.39 45 0.36 56 0.51 106 0.34 127 0.20 132 1.29 46 0.26 1.74 1.59 1.18 1.37 1.55 1.72 1.96 0.96 1.61 1.45 1.41 1.32 1.03 1.20 0.12 1.10 0.47 1.36 0.86 1.29 27 31 26 41 23 40 22 14 32 18 10 36 19 55 47 45 17 58 11 44 so P2 P2 P2 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21A

{TUBES WITH SERVICE INDUCED INDICATIONS}

ROW COL IND DNI DSI DSI DNI LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO TEC TEC TEC TEC 21 75 08C

-0.02 1.35 47 P1 TEH 21 78 08H 0.03 22 7

02H 0.17 22 12 03H 0.15 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 18 DNI 08C

-0.07 21 DSI 02H 0.12 21 DSI 03H 0.02 23 DSI 02H 0.07 25 DSI 02H 0.17 51 DNI 03H 0.00 51 DNI 07H 0.15 53 DNI 03H 0.00 53 DNI 04H 0.10 53 DNI 06H 0.07 53 DNI 07H 0.17 59 DNI 05H 0.02 65 DNI 07H 0.05 66 DNI 03H

-0.02 66 DNI 06H 0.00 68 DNI 05H 0.10 72 DNI 04H

-0.02 74 DNI 04H

-0.20 74 DNI 08H

-0.08 76 DNI 05H 0.02 10 DNI 07H 0.00 11 DSI 02H 0.05 11 DSI 03H 0.00 19 DSI 02H 0.02 19 DNI 03H 0.17 19 DNI 04H 0.15 20 DSI 02H

-0.07 20 DNI 08C 0.00 21 DSI 03H 0.02 26 DNI 04H

-0.07 26 DNI 05C 0.00 32 DNI 08C

-0.02 33 DNI 07H 0.05 46 DNI 03H

-0.25 46 DNI 06H

-0.15 46 DNI 07H

-0.17 46 DNI 08C 0.17 52 DNI 04H

-0.02 Page 16 of 23 0.13 0.32 1.46 1.61 0.53 116 95 53 35 29 0.25 57 0.19 143 0.30 87 1.25 49 1.34 55 1.61 20 2.00 18 1.31 23 1.42 6

1.28 29 1.60 1.51 1.54 1.29 1.27 2.16 2.41 1.37 1.34 1.14 0.42 0.92 1.47 1.52 20 42 29 32 56 17 16 28 56 21 42 36 41 46 0.19 120 1.32 38 0.42 1.55 1.25 1.26 1.28 1.75 1.87 1.60 1.40 1.32 94 51 54 53 48 32 55 53 21 54 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 TEH TEH TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21A

{TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 23 53 DSI 02H 0.15 0.49 32 P1 TEH TEC 23 23 23 23 23 23 23 23 24 24 24 24 24 24 24 24 24 24 53 DNI 04H 0.10 53 DNI 05H

-0.17 53 DNI 07H 0.10 53 SAl 02H

-0.07 55 DNI 05H 0.17 59 DNI 06H

-0.20 80 DNI 07H 0.00 81 DNI 04H

-0.02 16 DSI 02H 0.07 16 DSI 03H 0.02 17 DNI 05H 0.12 23 DSI 05H

-0.05 23 SAl 05H

-0.09 24 DSI 02H 0.02 24 DNI 05H 0.02 26 SCI TSH

-0.02 29 DNI 07H 0.08 29 DNI 08H 0.13 24 33 DSI 03H 0.02 24 43 DNI 05H 0.15 24 43 DNI 06H 0.17 24 47 DNI 06H 0.17 24 51 DNI 03H 0.22 24 52 DSI 02H 0.17 24 59 DNI 04H 0.02 24 63 DSI 05H 0.02 24 80 DNI 05H 0.02 24 85 DNI 05H 0.00 25 21 DSI 02H 0.17 25 25 25 26 26 26 26 26 26 26 26 26 22 DSI 02H 0.02 30 DSI 04H 0.05 53 DNI 06H 0.12 15 DSI 03H 0.02 17 DNI 08H 0.15 19 DSI 04H 0.17 34 MCI TSH

-0.04 36 DNI 03H 0.05 36 DNI 04H

-0.02 42 DSI 02H 0.15 43 DNI 04H 0.00 43 DNI 05H 0.12 0.19" 0.25" 0.18" 1.22 0.93 1.03 37° 0.11 1.05 1.02 1.60 1.46 43 52 35 66 38 19 21 56 0.29 163 0.18 86 1.48 51 0.78 12 0.09 109 0.31 1.65 35 33 37° 0.13 107 1.50 23 1.48 31 0.28 54 1.27 51 1.29 41 1.04 45 1.18 25 0.19 69 1.47 21 0.38 160 1.34 22 1.29 27 0.23 47 0.77 0.58 1.37 0.34 1.35 0.29 0.23" 146° 0.23 16 34 24 75 43 37 94 29 12 44 16 46 Page 17 of 23 1.61 1.83 0.56 1.00 1.32 P1 P1 P1 6

P1 P1 P1 P1 P1 P1 P1 P1 6

P1 P1 P2 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 P1 P1 P1 P1 P1 TEH TEC TEH TEC TEH TEC 02H 02H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 05H 05H TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND ONI ONI ONI LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO TEC TEC TEC 26 43 06H 0.12 1.09 46 P1 TEH 26 44 26 45 07H

-0.15 04H

-0.02 45 DNI 05H 0.00 53 DNI 05H 0.17 55 DNI 06H 0.17 62 DNI 03H 0.00 62 DNI 04H 0.00 80 DSI 05H

-0.02 15 DNI 04H 0.10 18 DNI 07H

-0.10 32 DSI 02H

-0.02 33 DSI 03H

-0.05 34 DSI 04H 0.12 42 DSI 04H 0.02 42 DSI 05H

-0.02 42 SAl 04H

-0.02 47 DSI 02H 0.12 47 DNI 07H

-0.05 64 DSI 02H 0.02 64 DNI 07H 0.02 71 PCT AV2 0.03 17%

71 PCT AV3 0.00 20%

71 PCT AV4 0.00 14%

75 DSI 05H 0.00 75 DNI 08H 0.00 75 PCT AV3 0.05 11%

13 DSI 03H 0.17 17 DNI 05H 0.10 26 DSI 04H 0.00 0.17" 1.35 1.33 1.38 1.19 1.08 1.27 1.40 0.28 1.11 1.25 0.39 0.62 0.60 0.31 0.55 0.07 0.48 1.19 0.15 1.32 1.31 15 33 54 64 32 25 24 36 8

20 37 53 70 60 18 95 75 17 50 43 0

1.61 0

0.98 0

0.21 128 1.25 33 0.76 0

0.23 133 1.29 48 0.47 29 26 26 26 26 26 26 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 28 28 28 28 28 28 SAl TSH 0.02 0.19" 61° 0.10 45 41 DSI 02H 0.15 28 41 DNI 05H 0.17 28 41 DNI 06H 0.02 28 41 DNI 07H 0.00 28 42 DNI 03H 0.07 28 45 DSI 02H

-0.07 28 45 DNI OSH 0.10 28 28 28 28 46 DSI 03H 0.12 54 DSI 02H 0.15 56 DSI 03H 0.15 66 DSI 04H 0.07 Page 18 of 23 0.46 1.45 1.25 1.32 1.54 0.34 1.10 52 50 53 49 50 74 22 0.48 44 0.33 58 0.31 137 0.12 60 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 6

P1 P1 P1 P1 P2 P2 P2 P1 P1 P2 P1 P1 P1 6

P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 TEH TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 04H 04H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21A

{TUBES WITH SERVICE INDUCED INDICATIONS}

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 28 66 SAl 04H

-0.15 0.19" 180° 0.13 124 6

04H 04H 28 28 29 29 29 29 29 29 29 29 29 29 29 30 30 30 30 30 30 30 30 30 30 30 68 SAl TSH 0.09 75 DNI 07H 0.00 19 DNI 08H 0.08 24 DSI 04H 0.12 25 DNI 07H 0.13 29 DNI 03H

-0.07 54 DSI 03H 0.20 54 MAl 03H 0.00 62 DNI 02H

-0.10 63 SCI TSH

-0.04 65 DSI 02H

-0.02 67 DNI 03H 0.00 72 PCT AV1 0.00 12%

19 DSI 02H 0.02 20 DNI 08H 0.30 22 DSI 02H 0.05 28 DSI 03H 0.02 38 DSI 02H 0.00 38 DNI 06H

-0.10 40 DNI 06H 0.12 51 DNI 04C

-0.25 58 DSI 04H

-0.17 63 DSI 08H 0.07 68 DSI 02H

-0.05 30 77 DNI 05H 0.00 31 14 DSI 04H 0.12 31 18 DSI 02H 0.05 31 18 DSI 03H 0.00 31 22 DNI 06H

-0.10 31 24 DNI 02H 0.20 31 34 DNI 04H

-0.05 31 35 DNI 07H 0.15 0.12" 67° 0.40 1.24 1.65 0.57 1.25 1.85 0.40 0.34" 180° 0.10 38 36 22 17 36 18 48 98 39 65 19 39 0

1.47 0.00" 180° 0.13 0.24 1.29 0.77 0.32 53 1.32 22 0.60 26 0.29 145 0.20 51 1.45 24 1.40 17 1.39 12 0.33 2

0.15 107 0.31 22 1.15 57 0.20 138 1.06 35 0.54 47 1.39 34 1.34 4

1.42 4

1.68 4

31 67 SCI TSH

-0.03 0.17" 56° 0.19 102 31 68 PCT AV2

-0.47 18%

31 68 PCT AV3 0.00 26%

31 69 PCT AV3 0.00 13%

31 76 NQI 01C 3.84 32 32 32 32 22 DSI 02H 0.15 27 DSI 03H 0.10 27 DNI 04H

-0.02 29 DNI 06H 0.25 Page 19 of 23 1.37 0

2.42 0

0.88 0

0.15 104 0.47 0.38 1.44 1.42 54 28 14 25 6

P1 P1 P1 P1 P1 P1 6

P1 P2 P1 P1 P2 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 P2 P2 P2 3

P1 P1 P1 P1 TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 03H 03H TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC STH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND DNI DSI LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO TEC TEC 32 36 04H 0.00 1.30 31 P1 TEH 32 38 03H

-0.07 45 DSI 02H 0.02 51 DSI 05H 0.15 53 DSI 03H 0.10 18 DSI 02H 0.02 18 DSI 03H 0.02 29 MAl TSH

-0.01 0.19" 42 DSI 05H 0.17 45 DSI 07H

-0.07 54 DSI 06H

-0.07 57 DSI 04H

-0.02 66 DSI 02H

-0.10 69 PCT AV2 0.00 14%

69 PCT AV3 0.00 17%

70 PCT AV1 0.00 17%

74 PCT AV1 0.00 15%

26 DNI 04H 0.17 33 DNI 02H 0.05 33 DNI 03H 0.10 38 DNI 03H

-0.07 41 DNI 04H 0.17 48 PCT AV2

-0.34 17%

48 PCT AV3 0.00 14%

48 PCT AV3

-0.12 28%

52 DSI 02H 0.00 53 DSI 02H 0.06 56 DSI 05H

-0.02 69 PCT AV2 0.00 20%

69 PCT AV3 0.00 40%

69 PCT AV4 0.00 17%

69 WAR AV4 0.00 70 PCT AV1 0.00 11%

70 PCT AV2 0.00 18%

70 PCT AV3 0.00 22%

32 32 32 33 33 33 33 33 33 33 33 33 33 33 33 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 35 35 35 35 35 35 35 36 SAl TSH 0.07 0.17" 36 DSI 03H 0.07 38 DNI 03H 0.22 45 DSI 02H 0.17 45 DNI 04H 0.00 45 DNI 05H

-0.07 45 DNI 06H

-0.10 0.29 0.35 0.22 0.53 0.20 0.39 61° 0.14 0.25 85 43 58 41 86 44 60 80 0.30 45 0.28 130 0.39 22 0.52 17 0.90 0

1.21 1.27 1.01 1.29 1.42 1.55 1.42 1.35 1.21 0.94 2.68 0.13 0.28 0.62 0

0 0

23 27 27 16 41 0

0 0

59 95 23 1.50 0

4.73 0

1.18 0

0.20 121 0.66 0

1.31 1.68 88° 0.14 0.51 1.28 0.67 1.45 1.56 1.65 0

0 79 38 38 44 43 53 46 Page 20 of 23 P1 P1 P1 P1 P1 P1 6

P1 P1 P1 P1 P1 P2 P2 P2 P2 P1 P1 P1 P1 P1 P2 P2 P2 P1 P1 P1 P2 P2 P2 2

P2 P2 P2 6

P1 P1 P1 P1 P1 P1 TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC STH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC STH TEC STH TEC TEH TEC TEH TEC TEH TEC TEH TEC 08C AV4 TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS}

ROW COL IND DNI DNI PCT PCT PCT LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO TEC TEC TEC TEC TEC 35 45 07H

-0.15 08H 0.11 35 45 35 68 AV1

-0.40 14%

35 70 AV3 0.00 13%

35 72 AV1 0.00 19%

35 36 36 36 36 36 36 36 36 36 37 37 37 37 37 37 37 37 37 38 38 38 38 38 38 38 38 38 38 38 38 38 38 39 39 39 39 72 PCT AV3 0.00 17%

23 DNI 06H 0.17 28 DSI 03H 0.15 28 DSI 04H 0.17 37 DNI 02H 0.07 37 DNI 03H 0.10 42 SCI TSH

-0.11 44 DSI 03H 0.00 46 DSI 06H 0.05 46 DNI 07H 0.00 26 DNI 07H 0.23 39 DSI 03H 0.00 42 DSI

. 03H 0.12 43 DNI 06H

-0.02 53 DNI 06H 0.07 54 DSI 05H 0.00 56 DSI 02H 0.02 56 DSI 03H

-0.02 56 DNI 04H 0.02 26 DNI 05H 0.29 37 DNI 03H 0.15 37 DNI 04H

-0.17 40 DSI 05H 0.17 44 DSI 02H 0.00 45 DNI 07H

-0.02 48 DNI 03H 0.05 52 DNI 03H 0.00 52 DNI 05H 0.00 52 DNI 06H 0.00 52 DNI 07H 0.00 52 DNI 08H

-0.15 72 PCT AV1 0.00 19%

72 PCT AV2 0.00 15%

23 DSI 02H 0.17 31 DNI 04H 0.12 38 PCT AV3 0.00 15%

42 DSI 02H 0.12 1.89 1.28 0.94 0.82 1.40 1.23 1.44 0.47 0.43 1.83 1.29 39 30 0

0 0

0 32 50 37 16 52 0.23" 56° 0.13 105 Page 21 of 23 0.48 56 0.16 81 1.26 51 1.44 17 0.49 0.59 1.40 1.24 0.26 0.25 0.53 1.38 1.65 1.83 35 54 34 23 86 43 50 58 16 13 1.83 38 0.49 117 0.59 28 1.49 57 1.66 17 1.60 20 1.18 35 1.29 41 1.84 1.31 1.39 1.01 1.12 1.31 0.98 0.70 22 24 0

0 18 27 0

48 Pl Pl P2 P2 P2 P2 Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 P2 Pl Pl P2 Pl TEH TEH TEH TEH TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 39 46 DSI 02H

-0.05 0.46 154 Pl TEH TEC 39 39 39 39 39 39 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 41 41 41 41 41 41 41 41 41 42 42 42 42 42 42 42 42 43 48 SCI TSH

-0.07 51 DNI 06H

-0.02 54 DNI 02H

-0.12 57 DSI 03H 0.17 66 DNI 08H 0.00 68 PCT AV1 0.00 9%

31 DNI 08H

-0.05 33 DNI 08H 0.02 37 DSI 03H 0.10 41 SCI TSH

-0.09 44 DNI 05H 0.00 44 DSI 06C 0.00 45 SCI TSH 0.05 48 DNI 05H 0.00 48 DNI 07H 0.00 48 MCI TSH

-0.03 54 DNI 04H 0.05 56 DNI 06H 0.02 56 DNI 07H

-0.02 66 PCT AV1 0.00 15%

69 PCT AV2 0.00 19%

69 PCT AV3 0.00 19%

69 PCT AV4 0.00 21%

32 DNI 05H 0.17 33 DNI 05H 0.24 45 SCI TSH

-0.04 52 DNI 03H 0.00 52 DNI 04H

-0.02 68 PCT AV2 0.00 10%

68 WAR AV1 0.02 68 WAR AV2

-0.04 68 PCT AV1 0.00 13%

30 DNI 08H

-0.02 37 PCT AV3

-0.03 15%

37 WAR AV3

-0.03 43 SVI TSH 2.01 43 SVI TSH 2.06 54 PSI 01C 0.10 54 PSI 01H

-0.19 64 DSI 04H 0.02 42 PCT AV1 0.00 21%

0.21" 283° 0.21 124 1.57 1.12 0.42 1.31 0.54 1.17 1.37 0.77 40 22 49 41 0

0.19" 143° 0.24 28 48 40 59 45 75 85 44 39 1.32 0.11 0.23" 238° 0.44 1.59 1.55 0.21" 188° 0.12 112 1.55 47 1.31 1.41 0.97 1.38 1.36 1.53 1.43 1.52 0.23" 124° 0.23 37 31 0

0 0

0 19 22 72 53 46 0

0.34" 0.29" 1.72 1.37 0.62 0.17 112 0.30 127 0.18 113 1.86 18 0.96 0

0.32 76° 1.30 71° 0.66 118 83 91 5.18 130 4.94 127 0.55 1.59 49 0

Page 22 of 23 P2 Pl Pl Pl Pl P2 Pl Pl Pl P2 Pl Pl P2 Pl Pl P2 Pl Pl Pl P2 P2 P2 P2 Pl Pl P2 Pl Pl P2 2

2 2

Pl P2 2

3 3

8 8

Pl P2 TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC 08H AV2 08H AV2 08H AV1 TEH TEC TEH TEC 08C AV3 SBH STH SBH STH TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS}

ROW COL INO LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 43 44 DNI 03H 0.00 1.25 54 Pl TEH TEC 43 44 DNI 04H 0.00 1.40 47 Pl TEH TEC 43 45 DNI 04H

-0.15 1.56 7

Pl TEH TEC 43 48 DNI 04H 0.00 1.29 28 Pl TEH TEC 43 50 DNI 03H

-0.05 1.61 21 Pl TEH TEC 43 50 DNI 04H 0.02 1.35 51 Pl TEH TEC 43 54 PSI 01C 0.12 5.45 137 8

TEH TEC 43 54 DNI 04H

-0.07 1.40 23 Pl TEH TEC 43 57 PCT AV1 0.00 14%

1.05 0

P2 TEH TEC 44 35 DSI 03H

-0.05 0.70 25 Pl TEH TEC 44 42 PCT AV1 0.00 17%

1.16 0

P2 TEH TEC 44 42 PCT AV2

-0.24 20%

1.46 0

P2 TEH TEC 44 48 PCT AV1 0.00 11%

0.70 0

P2 TEH TEC 44 48 PCT AV2 0.00 11%

0.71 0

P2 TEH TEC 44 so DNI 03H

-0.07 1.24 25 Pl TEH TEC 44 55 PCT AV3

-0.03 19%

1.54 0

P2 TEH TEC 44 55 PCT AV4 0.00 22%

1.94 0

P2 TEH TEC 44 55 WAR AV3

-0.03 0.24 119 2

08C AV3 44 55 WAR AV4 0.00 0.63 128 2

08C AV3 44 58 DSI 06H

-0.05 0.21 73 Pl TEH TEC 45 40 PCT AV1 0.00 32%

3.48 0

P2 TEH TEC 46 52 DSI 06H

-0.02 0.28 42 Pl TEH TEC Page 23 of 23

Attachment B BEAVER VALLEY UNIT #2 2R17 SG EXAMINATION RESULTS 2RCS-SG21 B TUBES WITH SERVICE INDUCED INDICATIONS

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 1

43 DSI 02H 0.00 0.50 109 P1 08H TEH 1

46 DNI 04H

-0.07 1.21 50 P1 08H TEH 1

1 1

2 2

2 2

2 2

2 2

2 2

2 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 4

4 4

4 52 DSI 02H

-0.04 56 DSI 02H 0.07 57 DSI 04H 0.06 9

DNI 07H 0.00 24 DSI 02H

-0.04 28 DSI 02H 0.00 54 DSI 04H 0.03 62 DSI 03H

-0.01 63 DSI 04H

-0.01 67 DSI 06H 0.09 70 DSI OSH 0.19 73 DSI 03H

-0.01 73 DSI 04H 0.01 94 DSI 04H 0.00 32 DSI 03H

-0.01 48 DNI 02H 0.02 48 DNI 04H

-0.03 48 DSI OSH 0.10 48 DNI 07H 0.04 53 DNI 04H 0.00 54 DSI 02H 0.00 55 DSI 02H

-0.19 60 DSI 02H 0.01 60 DSI 03H

-0.09 61 DNI 02H

-0.03 61 DNI 04H

-0.01 61 DNI OSH

-0.22 61 DSI 06H 0.04 61 DNI 08H 0.00 62 DSI 03H

-0.04 62 DSI 04H 0.00 63 DSI 02H

-0.04 63 DSI 03H

-0.03 72 DSI 03H

-0.03 88 DSI 04H 0.01 89 DSI 04H

-0.01 23 DN I 08C 0.00 23 DSI 02H 0.07 23 DSI 06H

-0.04 32 DSI 03H 0.03 1 of 17 0.45 81 0.40 79 0.73 31 1.49 60 0.44 89 0.57 53 0.29 47 0.64 57 0.44 30 0.40 87 0.82 74 0.25 112 0.48 33 0.51 66 0.28 108 2.10 48 1.93 54 0.98 1.75 1.58 19 42 55 0.62 100 0.77 115 0.72 86 0.66 63 1.58 36 1.40 52 1.29 29 0.31 83 1.42 30 0.48 30 0.26 so 0.95 65 0.68 84 0.65 30 0.58 so 0.54 36 1.27 49 0.27 135 0.26.

141 0.13 120 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08C TEC 08H TEH 08H TEH 08H TEH

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS}

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 4

34 SCI TSH

-0.09 0.16" 50° 0.10 90 P2 TSH TSH 4

4 4

4 4

4 4

4 4

4 4

4 4

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

41 DSI 04H 0.00 43 DSI 02H 0.00 44 DSI 02H

-0.01 48 DSI 03H 0.04 52 DSI 03H 0.04 54 DSI 02H

-0.07 56 DSI 04H

-0.03 57 DSI 02H 0.07 57 DSI 04H

-0.01 58 DSI 02H 0.01 59 DSI 02H

-0.07 59 DSI 03H 0.06 63 DSI 04H

-0.03 7

DNI 08H

-0.10 12 DSI 03H 0.22 13 DNI 08H

-0.05 14 DSI 03H 0.15 20 DSI 03H 0.00 22 DSI 04H

-0.07 22 DNI 05H 0.00 25 DNI 08H

-0.22 28 DSI 02H 0.12 32 DNI 08H

-0.17 34 NQI 03H 40.72 34 DNI 08H

-0.05 52 DSI 02H 0.25 54 DSI 02H 0.12 54 DSI 03H 0.00 54 DNI 06C

-0.07 56 DSI 03H 0.05 58 DSI 02H 0.02 60 DSI 02H 0.02 63 DSI 04H 0.12 64 DSI 02H 0.07 64 DSI 03H 0.07 68 DSI 02H 0.00 73 DSI 02H 0.02 75 DSI 04H 0.00 81 DSI 05H 0.00 82 DNI 08H 0.15 90 DNI 08H 0.02 2 of 17 0.23 66 0.30 24 0.35 37 0.55 58 0.58 58 0.52 76 0.34 144 0.49 96 0.29 95 0.54 116 0.32 104 0.33 50 0.69 20 1.41 28 0.27 55 1.69 22 0.64 66 0.34 89 0.63 42 1.50 1.27 0.62 1.75 0.35 1.27 0.60 47 18 63 15 51 29 54 0.40 104 0.24 57 1.29 0.53 17 36 0.24 90 0.30 97 0.19 135 0.38 63 0.38 64 0.43 49 0.49 41 0.20 121 0.33 27 1.38 49 1.25 37 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 3

P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND DSI DSI DSI DSI LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO TEC TEC TEC TEC 5

92 02H 0.15 0.40 46 Pl TEH 5

93 03H 0.00 0.28 36 Pl TEH 6

16 03H 0.05 6

23 04H 0.00 6

6 6

6 6

6 6

6 6

6 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

8 8

8 8

8 8

8 8

8 8

8 8

8 25 DNI 08H 0.00 26 DSI 02H

-0.05 27 DSI 03H 0.00 27 SAl 03H 0.00 52 DSI 02H

-0.05 53 DSI 02H 0.15 53 DSI 03H 0.05 58 DSI 02H 0.05 61 DSI 08H 0.06 63 DSI 02H 0.00 26 DNI 03H

-0.02 26 DNI 04C 0.00 26 DNI 04H 0.00 26 DNI 05C 0.00 26 DNI 05H 0.00 26 DNI 08H

-0.02 30 DNI 05H 0.10 33 DNI 03C 0.27 33 DNI 07H

-0.02 34 DN I 04H 0.00 52 DSI 02H 0.05 54 DSI 02H

-0.07 56 DSI 02H 0.10 63 DSI 07H 0.02 75 DSI 02H

-0.05 2

9 DSI 03H 0.15 DSI 02H 0.20 9

DSI 03H 0.17 18 DSI 02H

-0.02 18 DSI 03H 0.00 20 DSI 02H 0.05 22 DSI 02H 0.00 29 DNI 05H 0.00 31 DNI 06C 0.02 37 DSI 03H 0.17 53 DSI 02H 0.22 56 DSI 03H 0.00 59 DSI 02H 0.12 0.48" 3 of 17 0.32 0.25 1.41 0.21 23 73 20 50 0.29 62 39° 0.12 107 0.17 136 0.35 36 0.40 117 0.65 77 0.33 29 0.19 1.25 1.33 1.28 1.26 1.49 1.55 1.42 1.25 1.39 1.25 0.97 89 45 39 47 46 46 37 51 13 35 42 44 0.19 41 0.74 129 0.43 0.19 0.51 0.31 29 53 37 81 0.21 154 0.34 46 0.31 55 0.36 145 0.29 135 1.54 21 1.58 37 0.53 19 0.80 83 0.39 88 0.32 45 Pl Pl Pl Pl Pl 6

Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl TEH TEH TEH TEC TEH TEC TEH TEC 03H 03H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 8

63 DNI 04H 0.00 1.60 48 P1 TEH TEC 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 10 10 10 10 10 10 10 10 10 10 10 10 10 4

4 DSI 03H 0.15 SAl 03H 0.00 5

DSI 03H 0.17 8

DSI 03H 0.15 11 DSI 02H 0.20 11 DSI 03H 0.22 16 DSI 03H 0.00 17 DSI 02H 0.05 17 DSI 03H

-0.05 18 DSI 02H

-0.05 18 DSI 03H 0.05 19 DNI 08H 0.00 26 DSI 02H 0.15 26 DSI 03H 0.20 51 DNI 02H 0.02 52 DSI 02H 0.05 52 DSI 03H 0.07 59 DSI 03H 0.10 59 DSI OSH 0.07 64 DNI 03H 0.02 64 DSI 04H 0.02 64 SAl 04H 0.00 80 DSI 02H 0.00 80 DNI 07H 0.05 85 DSI 02H 0.00 92 DSI 02H 0.00 92 DNI 04H 0.25 93 DSI 02H 0.05 6

DSI 02H 0.20 10 DSI 02H

-0.05 14 DSI 02H 0.07 15 DSI 02H 0.10 17 DSI 02H

-0.05 18 DSI 02H

-0.05 26 DSI 02H 0.12 33 DNI 08H 0.10 37 DSI 03H 0.10 41 DSI 07H

-0.05 50 DSI 02H 0.02 50 DSI 03H 0.02 52 DSI 02H 0.02 0.18" 0.23" 4 of 17 0.30 108 35° 0.10 106 0.23 89 0.22 63 0.60 104 0.34 57 0.21 62 0.32 109 0.39 121 0.33 97 0.48 1.38 0.55 0.66 1.74 0.51 0.32 0.40 0.34 1.31 51 54 90 57 47 26 35 25 89 49 0.70 29 45° 0.13 36 0.49 75 1.47 51 0.63 49 0.41 101 1.30 49 0.35 125 0.57 95 0.18 16 0.31 92 0.40 141 0.35 129 0.53 47 0.59 27 1.34 12 0.23 141 0.30 93 0.29 117 0.24 73 1.17 100 P1 6

P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 6

P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 TEH TEC 03H 03H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 04H 04H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND DSI LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO TEC 10 52 04H 0.02 10 53 DSI 02H 0.10 10 54 DSI 02H 0.05 10 56 DSI 02H 0.05 10 58 DSI OSH 0.07 10 63 DSI 02H 0.00 10 71 DSI OSH 0.00 10 78 DSI 04H 0.00 10 80 DSI 03H 0.15 10 82 DSI 03H 0.17 10 10 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 88 DSI 04C

-0.10 89 DSI 02H

-0.02 8

8 8

9 9

9 DSI 03H 0.02 DSI 04H 0.00 DNI 07H 0.00 DSI 06H 0.00 DSI 07H 0.10 DNI 07H

-0.02 18 DSI 02H 0.02 20 DSI 02H 0.17 21 DSI 03H 0.02 25 DSI 03H 0.17 25 SAl 03H 0.00 29 DNI 04H

-0.02 31 DNI OSH 0.00 35 DSI 02H 0.02 42 DSI 03H 0.12 53 DSI 02H 0.00 53 DNI 06H 0.07 57 DSI 03H

-0.02 58 DSI 03H 0.02 58 DNI 06H 0.00 61 DSI 02H 0.00 61 DSI 03H 0.02 61 DNI 07H

-0.02 64 DSI 03H

-0.10 64 DNI 07H 0.07 66 DNI OSH 0.02 11 75 DSI 02H

-0.02 11*

78 DNI 06H 0.10 11 82 DNI 08H 0.01 11 83 DSI 03H 0.10 0.51" 5 of 17 0.37 38 0.48 80 0.28 47 0.43 104 0.22 73 0.31 35 0.35 131 0.27 93 0.20 72 0.25 31 0.12 106 0.40 57 0.25 0.17 1.33 0.34 0.35 1.61 75 56 51 12 30 52 0.74 96 0.64 109 0.33 41 0.41 54 37° 0.16 56 1.29 1.38 0.16 0.16 0.43 1.47 0.25 0.29 1.30 1.15 0.52 1.32 0.55 1.22 1.53 0.85 1.50 1.31 0.43 54 22 35 72 93 so 38 54 53 46 94 56 64 56 56 57 51 51 65 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 6

P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 03H 03H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND DSI DNI DNI DNI LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO TEC TEC TEC TEC 11 83 04H 0.10 0.73 45 Pl TEH 11 83 08H 0.16 11 85 06H 0.12 12 9

04H 0.00 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 14 14 14 14 14 14 14 10 DSI 02H 0.02 10 NQI 07H 48.90 11 DNI 04H 0.02 11 DNI 06H 0.00 15 DSI 02H 0.05 15 DSI 03H

-0.02 16 DSI 03H 0.00 22 DSI 02H 0.17 24 DSI 02H 0.00 24 DSI 04H 0.00 28 DNI 07H 0.00 51 DSI 02H 0.10 52 DSI 02H 0.02 52 DSI 03H

-0.05 61 DSI 03H 0.15 16 DSI 02H

-0.05 16 DSI 03H 0.00 16 DSI 06H 0.00 37 DSI 03H 0.09 39 DSI 07H 0.00 47 DSI 02H 0.00 47 SAl 02H

-0.05 53 DSI 02H

-0.12 53 DNI 06H 0.00 56 DSI 03H 0.07 73 DSI 02H 0.00 77 DSI 03H 0.00 78 DSI 02H 0.00 85 DSI 02H 0.00 86 DSI 02H 0.00 91 DSI 02H

-0.10 8

DSI 03H

-0.05 11 DNI 03C 0.00 11 DNI 03H 0.02 11 DNI 05C 0.02 11 DNI 06H 0.02 11 DNI 07C 0.02 11 DNI 07H 0.00 0.37" 6 of 17 1.28 1.34 1.44 0.48 0.54 53 53 53 74 78 1.33 55 1.24 46 0.26 100 0.60 66 0.21 149 0.43 131 0.55 113 0.45 141 1.28 49 0.15 95 0.57 69 0.74 0.89 47 23 0.59 128 0.18 107 0.39 0.30 23 66 0.16 70 0.29 39 50° 0.17 109 0.80 44 1.26 0.33 0.30 0.77 0.11 0.48 40 56 83 27 76 78 0.14 103 0.35 65 0.20 126 1.25 31 1.49 36 1.31 1.39 1.44 1.31 36 37 35 41 Pl Pl Pl Pl 3

Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl 6

Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl TEH TEH TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 02H 02H TEH TEC TEH TEC TEH TEC TEH TEC STH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS}

ROW COL IND LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 14 12 DNI 06H 0.00 1.34 49 Pl TEH TEC 14 13 DSI 02H 0.05 0.37 43 Pl TEH TEC 14 15 DSI 03H 0.17 0.37 131 Pl TEH TEC 14 15 DNI 05H 0.00 1.44 53 Pl TEH TEC 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 18 DSI 02H 0.00 24 DNI 06C 0.00 25 DSI 02H 0.02 27 DNI 02H 0.00 27 DSI 03H 0.00 28 DSI 05H 0.07 29 DNI 04H

-0.15 29 DNI 06H

-0.02 32 DSI 02H 0.10 35 DSI 06H 0.00 36 DSI 03H 0.20 36 DNI 07H 31.15 39 DSI 02H 0.07 54 DSI 02H 0.00 54 DSI 03H 0.05 57 DSI 02H 0.10 14 57 DSI 03H

-0.02 14 59 DNI 08C

-0.12 14 61 DSI 02H 0.10 14 61 DSI 03H 0.10 14 61 DSI 05H 0.02 14 63 DSI 03H 0.17 14 66 DNI 05H

-0.02 14 66 DNI 08C

-0.02 14 66 DNI 08H 0.00 14 14 14 15 15 15 15 15 15 15 15 15 15 70 DSI 02H 0.07 84 DSI 04H 0.00 88 DSI 02H 0.00 12 DSI 03H 0.12 16 DNI 08H 0.00 23 DNI 08H 0.00 24 DNI 08H

-0.08 26 DSI 03H 0.12 26 DSI 07H 0.18 27 DSI 02H 0.12 36 DSI 02H 0.05 36 DNI 03H 0.00 51 DSI 02H 0.05 7 of17 0.47 98 1.34 34 0.44 82 1.37 54 0.26 64 0.20 108 1.31 1.44 25 22 0.38 123 0.24 106 0.27 90 0.42 148 0.16 157 0.57 33 0.48 100 0.59 53 0.49 68 1.33 26 0.29 115 0.79 53 0.68 30 0.52 21 1.10 53 1.26 41 1.00 62 0.57 0.22 0.30 0.10 1.39 1.74 1.28 89 64 42 99 41 27 32 0.39 124 0.34 40 0.29 34 0.29 61 1.37 24 0.34 100 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl 5

Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

rEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 15 51 SAl 02H 0.12 0.22" 53° 0.26 77 6

02H 02H 15 15 15 15 52 DSI 02H

-0.05 60 DNI 03H 0.02 60 DNI OSH 0.00 60 DNI 06H 0.00 15 60 DNI 08H 0.15 15 65 DNI 04H 0.00 15 71 DSI OSH 0.07 15 75 DSI 02H 0.00 15 75 DSI 04H 0.00 15 80 DSI 04H 0.05 15 87 DSI 02H 0.07 16 26 DNI 07H 0.00 16 26 DNI 08H 0.03 16 27 DSI 03H 0.02 16 27 DNI OSC 0.00 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 17 17 17 17 17 17 17 17 28 DNI 02H

-0.17 28 DNI 04H

-0.07 28 DNI 06H

-0.22 28 DNI 08H

-0.18 30 PCT AV2

-0.03 10%

30 PCT AV3 0.19 9%

31 DSI 02H 0.17 31 DSI 07H

-0.02 37 DSI 02H 0.17 37 DSI 04H 0.15 37 SAl 04H

-0.07 42 MAl TSH

-0.12 44 DSI 02H 0.10 55 DSI OSH 0.15 55 DNI 06H 0.17 61 DSI 02H 0.10 62 DNI 07H

-0.02 71 DSI 02H 0.05 28 DNI 02C 0.12 28 DNI 03C 0.20 28 DNI 03H 0.00 33 SCI TSH

-0.12 33 DSI 02H 0.12 33 DSI 03H 0.12 33 SAl 03H

-0.05 35 DSI 03H 0.05 0.65 1.46 1.41 1.44 65 54 35 44 1.34 27 1.19 so 0.59 20 0.21 34 0.34 70 0.48 168 0.28 110 1.41 49 1.32 45 0.38 30 1.36 24 1.35 1.83 1.83 1.60 0.63 0.51 0.46 34 25 12 20 0

0 so 0.29 126 0.50 33 0.52 0.22" 53° 0.16 30 85 29 12 98 54 27 32 0.16" 141° 0.47 0.40 0.27 1.07 0.50 1.18 0.30 102 1.43 13 1.63 10 1.43 31 0.16" 273° 0.15 114 0.61 117 0.60 105 0.25" 55° 0.24 81 0.54 63 8 of 17 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 P2 P1 P1 P1 P1 6

6 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 P1 P1 6

P1 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC STH TEC STH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 04H 04H TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC 03H 03H TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 17 42 DSI 03H 0.05 0.53 65 P1 TEH TEC 17 17 17 17 17 17 17 17 17 17 17 17 17 17 18 18 18 18 18 18 18 18 44 DSI 02H 0.02 44 SAl 02H

-0.22 44 SAl 02H 0.11 62 DNI 02H 0.00 62 DNI 06H

-0.05 64 DSI 02H 0.00 68 DSI 02H 0.05 68 DSI 03H 0.02 68 DSI 04H

-0.02 68 DNI 05H 0.34 68 DNI 07H

-0.05 68 SAl 04H 0.22 83 DSI 06C

-0.07 84 DNI 04H

-0.07 12 DSI 03H 0.12 18 DSI 02H 0.07 21 DNI 05H

-0.07 21 DNI 06H

-0.02 28 DSI 04H 0.20 29 DSI 02H 0.10 30 DSI 04H 0.10 34 SCI TSH

-0.13 18 36 DSI 03H 0.07 18 37 DSI 03H 0.12 18 38 DSI 03H 0.12 18 42 DSI 02H 0.15 18 53 DSI 03H 0.05 18 53 DSI 04H 0.22 18 57 DSI 03H 0.20 18 58 DSI 02H 0.00 18 61 DSI 03H 0.17 18 64 DSI 03H 0.22 18 18 18 18 19 19 19 19 19 65 DNI 07H 0.05 69 DSI 05H

-0.05 76 DSI 03H 0.00 83 DNI 08C 0.12 7

DNI 07H 0.00 11 DNI 05H 0.00 11 DNI 06H

-0.02 11 DNI 07H

-0.02 15 DSI 02H 0.10 0.12" 0.10" 0.25" 0.16" 9 of 17 0.40 35 37° 0.08 98 39° 0.07 112 1.92 18 1.15 0.15 38 99 0.57 81 0.74 25 0.80 24 1.53 18 1.02 96 50° 0.12 69 0.20 122 1.82 0.23 0.22 1.48 1.28 62 19 79 21 32 0.28 125 0.81 64 0.25 100 63° 0.22 120 1.09 55 0.52 42 0.79 76 0.39 110 0.52 48 0.33 40 0.14 87 0.62 93 0.37 20 0.39 93 1.18 0.33 0.49 1.61 1.31 1.29 1.27 1.54 0.32 53 24 33 11 55 46 43 33 59 P1 6

6 P1 P1 P1 P1 P1 P1 P1 P1 6

P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 TEH TEC 02H 02H 02H 02H STH TEC STH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 04H 04H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 19 15 DSI 04H 0.05 0.12 25 P1 TEH TEC 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 20 15 DNI 08H 0.00 29 DSI 02H

-0.02 29 DSI 03H 0.05 36 DSI 02H 0.05 36 DNI 05H 0.00 39 DNI 03H

-0.12 39 DSI 03H

-0.02 39 DSI 04H 0.00 39 DNI 06H 0.07 39 DNI 07H 0.05 41 SCI TSH

-0.08 45 DSI 02H 0.05 45 DNI 07H 0.03 50 DSI 03H 0.17 50 DNI 05H 0.05 51 DSI 02H 0.02 51 DSI 03H 0.00 52 DNI 06H 0.02 71 DSI 05H

-0.02 72 DNI 06H 0.02 74 DSI 02H 0.00 76 DSI 02H 0.12 78 DSI 02H 0.00 83 PCT TSC 0.40 10%

83 VOL TSC 0.40 83 PCT TSC 1.41 12%

83 VOL TSC 1.41 85 DSI 02H 0.00 11 DSI 02H 0.30 20 11 DNI 07H 0.08 20 16 DSI 03H

-0.05 20 18 DNI 08H

-0.02 20 19 DSI 04H 0.02 20 22 DNI 08H

-0.07 20 23 DSI 02H 0.00 20 23 SAl 02H

-0.06 20 36 DNI 08H 0.10 20 45 SCI TSH

-0.08 20 59 SCI TSH

-0.08 20 20 70 DSI 02H

-0.07 81 DSI 02H 0.12 1.31 0.91 0.93 1.00 1.74 1.67 0.89 0.63 1.45 1.12 0.17" 138° 0.13 55 67 36 63 37 42 37 73 30 59 97 57 60 60 72 97 43 64 16 79 18 0.42 1.15 1.06 1.21 0.74 0.50 1.30 0.47 1.28 0.40 0.57 30 0.24 82 0.07 85 0.09 78 0.06 104 0.08 83 0.27 51 1.14 24 1.43 25 0.33 46 1.31 14 0.11 40 1.29 26 0.22 81 0.17" 47° 0.12 76 1.32 22 0.09" 106° 0.14 110 0.19" 169° 0.24 107 0.14 55 0.24 155 10 of 17 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 3

6 3

6 P1 P1 P1 P1 P1 P1 P1 P1 6

P1 P2 P2 P1 P1 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSC 01C TSC 01C TSC 01C TSC 01C TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 02H 02H TEH TEC TSH TSH TSH TSH TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND DSI LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 20 89 02H 0.02 0.33 80 P1 TEH TEC 21 21 21 21 21 21 21 21 21 21 22 22 22 22 22 22 22 22 22 22 22 23 23 23 23 23 23 23 23 23 23 23 24 24 24 24 24 24 24 24 24 12 DNI 06H 0.00 13 DNI 08H 0.00 23 DNI 07H 0.03 27 DNI 08H 0.16 45 DSI 04H 0.00 49 DNI 03H 0.02 53 DSI 03H 0.10 53 DSI 05H 0.02 54 DSI 02H

-0.02 75 DSI 02H 0.12 12 DSI 03H 0.17 18 DSI 03H 0.12 18 DNI 06H 0.02 18 SAl 03H 0.07 36 DSI 03H 0.00 40 DNI 08H

-0.15 52 DSI 02H

-0.02 52 DSI 03H

-0.02 53 DSI 02H

-0.07 62 DSI 03H 0.07 64 DSI 02H 0.00 10 DNI 03H 0.00 33 DSI 03H 0.05 37 DNI 02H 0.02 37 DSI 04H 0.10 37 SAl 04H

-0.09 56 DSI 02H

-0.05 61 DSI 02H

-0.05 63 DSI 03H

-0.02 63 DSI. 05H 0.02 67 DSI 05H

-0.02 86 DSI 02H 0.00 15 DNI 03H 0.00 29 DSI 05H 0.05 30 DSI 03H

-0.02 32 DSI 03H 0.02 42 DSI 02H

-0.02 51 DSI 08H 0.06 52 DSI 02H 0.07 56 DSI 02H

-0.02 58 DSI 03H 0.15 0.30" 0.17" 11 of 17 1.29 44 1.44 22 1.30 26 1.36 10 0.38 133 1.17 69 0.42 57 0.21 1.40 98 50 0.29 145 0.14 0.72 1.28 55° 0.11 0.22 23 11 35 63 43 1.27 25 0.27 42 0.29 62 0.16 124 0.50 33 0.54 98 1.27 0.45 1.41 0.59 39° 0.07 56 21 23 16 98 0.57 157 0.25 55 0.31 40 0.19 79 0.26 150 0.28 45 1.26 50 0.27 25 0.29 114 0.36 83 0.87 51 0.73 169 0.47 73 0.55 113 0.28 86 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 6

P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 6

P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 03H 03H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 04H 04H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL JND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 24 62 DSI 03H 0.05 0.51 48 P1 TEH TEC 24 63 DSI 03H 0.02 0.48 25 P1 TEH TEC 24 68 DSI 08H 0.00 0.34 36 P1 TEH TEC 24 24 25 25 25 25 25 25 25 25 25 25 25 25 71 DSI OSH 0.00 84 DSI OSH 0.02 12 DNI OSH

-0.15 13 DNI OSH

-0.02 17 DSI 02H 0.17 17 DNI 04H

-0.02 18 DNI 06H 0.02 23 PCT AV3 0.00 15%

24 DSI 03H 0.02 29 DSI 02H 0.02 45 SAl AV1 3.68 63 DNI 06H 0.02 64 DSI 06H 0.05 79 DSI 08H 0.04 26 13 DNI 03H

-0.27 26 16 DNI 02H

-0.10 26 20 DNI 06H 0.02 26 30 DSI 03H

-0.10 26 39 DSI 03H

-0.05 26 78 DSI 02H 0.00 27 36 DSI 06H

-0.02 27 46 DSI 06H 0.12 27 52 DSI 04H

-0.02 27 53 DSI 03H 0.07 27 68 DSI 02H 0.02 28 30 DNI OSH 0.00 28 38 DNI OSH

-0.07 28 41 DSI 02H

-0.05 28 60 DNI 04H 0.05 28 28 28 28 29 29 29 29 29 29 63 DSI 03H

-0.02 70 PCT AV3 0.00 28%

70 PCT AV4 0.00 23%

81 DSI 02H

-0.02 18 DNI 04H 0.00 20 DSI 03H 0.02 20 DNI OSH

-0.02 25 DNI OSH 0.00 27 DSI 03H 0.00 31 DSI OSH

-0.05 0.37" 12 of 17 0.39 0.30 37 88 1.32 16 1.39 50 0.28 160 1.33 40 1.52 0.88 0.70 0.23 50° 0.49 1.23 24 0

42 63 71 16 0.33 26 0.57 132 1.66 1.30 1.33 0.75 0.16 0.31 0.25 0.33 0.48 0.35 0.30 1.37 1.89 0.59 1.41 0.52 2.50 1.81 0.27 1.43 0.87 1.47 1.35 0.66 0.24 14 49 33 89 68 41 29 29 15 26 45 35 32 37 30 43 0

0 47 45 27 48 25 68 93 P1 P1 P1 P1 P1 P1 P1 P2 P1 P1 2

P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 P2 P1 P1 P1 P1 P1 P1 P1 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 08H AV2 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21B

{TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 29 32 DSI 03H 0.02 0.10 46 P1 TEH TEC 29 29 29 29 29 29 29 29 29 29 29 29 32 DSI 05H 0.00 34 DSI 03H 0.07 35 DSI 04H 0.02 35 SAl 04H 0.04 37 DSI 03H 0.07 38 DSI 02H 0.00 38 DNI 07H 0.02 38 MAl 02H 0.02 40 DSI 03H 0.05 41 DSI 02H 0.17 56 DSI 02H 0.15 56 DNI 04H 0.07 30 16 DSI 04H 0.05 30 20 DSI 04H 0.00 30 24 DNI 06H 0.00 30 27 DSI 02H

-0.07 30 32 DSI 03H 0.00 30 34 DNI 04H

-0.15 30 48 DNI 04H

-0.02 30 30 30 30 30 30 30 30 30 31 31 50 DSI 04H 0.07 53 PCT AV3 0.10 17%

55 DSI 03H 0.12 56 DNI 04H

-0.07 59 DSI 04H 0.02 78 DSI 02H 0.02 78 DSI 04H 0.02 79 DSI 02H 0.02 81 DSI 03H 0.02 19 DNI 06H 0.00 21 DSI 07H 0.02 31 23 DSI 02H 0.27 31 31 DNI 05H 0.02 31 32 DNI 02H

-0.10 31 32 DSI 03H

-0.02 31 32 DSI 05H

-0.05 31 32 DNI 06H 0.00 31 37 DSI 03H 0.00 31 39 DSI 02H 0.02 31 39 DSI 03H 0.05 31 41 PCT AV1 0.00 16%

31 41 PCT AV2 0.00 13%

0.20" 0.22" 13 of 17 0.27 0.39 0.44 40 64 24 37° 0.15 112 0.72 23 0.48 1.17 92° 0.12 0.87 0.43 1.06 1.22 56 56 42 57 33 91 44 0.22 47 0.22 62 1.34 46 0.44 38 0.16 114 1.28 33 1.29 54 0.75 1.07 0.40 1.01 36 0

97 36 0.24 18 0.50 28 0.35 37 0.38 45 0.29 91 1.35 49 0.29 111 0.58 77 1.24 43 1.55 39 0.37 36 0.37 139 1.26 30 0.50 49 0.38 34 0.59 42 1.03 0

0.75 0

P1 P1 P1 6

P1 P1 P1 6

P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 P2 TEH TEC TEH TEC TEH TEC 04H 06H TEH TEC TEH TEC TEH TEC 02H 02H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 31 41 PCT AV3

-0.01 23%

1.75 0

P2 TEH TEC 31 31 31 31 31 31 31 31 31 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 33 33 33 33 33 33 33 33 33 33 33 49 DNI 03H

-0.07 52 DSI 02H

-0.10 59 PCT AV2 0.00 12%

59 PCT AV3 0.00 24%

59 PCT AV4 0.00 17%

71 DSI 05H 0.12 76 DSI 02H 0.21 78 DSI 02H

-0.10 78 DSI 03H 0.15 17 DNI 08H

-0.22 24 DNI 02H

-0.02 29 DSI 05H 0.02 31 DSI 02H 0.10 31 SAl 02H 0.22 33 DNI 02H

-0.12 33 DNI 08H 0.00 35 DNI 02H

-0.02 50 PCT AV2 0.00 26%

50 PCT AV3 0.00 13%

53 DSI 02H 0.10 55 DSI 02H 0.10 55 DSI 05H

-0.02 55 PCT AV3 0.00 27%

55 PCT AV4

-0.25 19%

57 PCT AV1 0.00 18%

57 PCT AV3 0.00 19%

59 PCT AV3 0.00 24%

61 DSI 02H 0.05 61 DSI 05H 0.00 77 DSI 02H

-0.02 31 DSI 07H 0.00 32 DSI 02H 0.07 37 DSI 04H

-0.05 40 PCT AV2

-0.20 22%

40 PCT AV3 0.05 21%

41 PCT AV1 0.00 15%

41 PCT AV2 0.70 28%

41 PCT AV2 0.45 25%

41 PCT AV3 0.21 19%

44 DSI 02H

-0.07 55 PCT AV2

-0.07 13%

0.18" 14 of 17 1.25 30 0.69 51 0.71 0

1.91 0

1.15 0

0.22 57 0.46 67 0.34 130 1.06 69 1.25 1.58 0.21 0.30 37° 0.09 1.33 1.26 1.44 2.19 0.75 0.81 0.71 0.31 2.51 1.30 1.20 1.33 1.97 14 24 77 14 65 35 17 49 0

0 60 67 84 0

0 0

0 0

0.41 71 0.39 140 0.41 65 0.33 41 0.42 144 0.20 1.65 1.58 0.86 2.55 2.14 1.26 0.65 0.78 23 0

0 0

0 0

0 70 0

Pl Pl P2 P2 P2 Pl Pl Pl Pl Pl Pl Pl Pl 6

Pl Pl Pl P2 P2 Pl Pl Pl P2 P2 P2 P2 P2 Pl Pl Pl Pl Pl Pl P2 P2 P2 P2 P2 P2 Pl P2 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 01H 02H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 33 57 PCT AV1 0.00 17%

1.12 0

P2 TEH TEC 33 33 33 33 33 33 33 33 34 34 34 34 34 34 34 34 34 57 PCT AV2 0.00 20%

62 DSI 02H 0.07 63 PCT AV2 0.00 29%

63 PCT AV3

-0.08 16%

63 PCT AV4 0.00 18%

63 WAR AV4 0.00 65 PCT AV1 0.00 12%

65 PCT AV2 0.00 20%

22 PCT AV2 0.00 11%

22 PCT AV4 0.00 11%

22 WAR AV2 0.00 32 DSI 02H

-0.02 35 DSI 03H 0.05 35 NQI AV2 9.00 36 DNI OSH 0.00 37 DSI 03H 0.05 48 DSI 02H

-0.02 34 48 DSI 03H 0.22 34 48 DSI 04H 0.12 34 48 SAl 02H 0.15 0.20" 34 50 PCT AV1 0.00 22%

34 34 34 34 34 34 34 34 34 34 35 35 35 35 35 35 35 35 35 35 50 PCT AV3 0.00 24%

50 PCT AV4

-0.09 15%

51 DSI 02H

-0.07 51 DSI 03H

-0.05 51 DNI 08H 0.02 55 PCT AV1 0.00 18%

55 PCT AV2 0.06 17%

55 PCT AV3 0.03 37%

57 DSI 02H 0.00 57 PCT AV2 0.46 23%

19 PCT AV4 0.00 18%

21 PCT AV3 0.00 20%

25 DNI 04H

-0.17 25 PCT AV2 0.00 30%

25 PCT AV3 0.00 32%

25 PCT AV4 0.20 26%

40 DSI 02H 0.00 40 PCT AV2 0.00 19%

40 WAR AV2 0.00 41 PCT AV1 0.00 22%

15 of 17 1.41 0.83 0

56 2.71 0

1.01 0

1.17 0

0.36 124 0.71 0

1.39 0

0.66 0

0.67 0

0.16 109 0.27 0.36 4.19 1.47 0.45 0.60 73 34 61 21 20 96 0.66 58 0.37 46 31° 0.11 131 1.56 0

1.86 0.89 0.72 0.87 1.32 1.18 1.08 4.71 0.45 1.86 1.04 1.27 1.29 2.94 3.40 2.13 0.43 0

0 so 91 56 0

0 0

21 0

0 0

14 0

0 0

58 1.25 0

0.19 167 1.72 0

P2 P1 P2 P2 P2 2

P2 P2 P2 P2 2

P1 P1 6

P1 P1 P1 P1 P1 6

P2 P2 P2 P1 P1 P1 P2 P2 P2 P1 P2 P2 P2 P1 P2 P2 P2 P1 P2 2

P2 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 08C AV4 TEH TEC TEH TEC TEH TEC TEH TEC 08H AV2 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 02H 02H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 08H AV2 TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS}

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 35 41 PCT AV2 0.51 28%

2.60 0

P2 TEH TEC 35 35 35 35 35 35 41 PCT AV2

-0.59 23%

41 PCT AV3

-0.29 18%

41 PCT AV3 0.36 14%

41 PCT AV4 0.00 29%

50 PCT AV1 0.00 22%

50 PCT AV2 0.00 19%

35 50 PCT AV3 0.00 26%

35 50 PCT AV4 0.00 21%

35 54 PCT AV1 0.18 13%

35 63 PCT AV2 0.49 35%

35 63 PCT AV2

-0.15 21%

35 63 PCT AV3 0.00 43%

35 63 PCT AV4 0.00 19%

35 71 PCT AV2 0.00 11%

35 71 PCT AV4 0.00 10%

36 36 36 36 36 19 PSI 06H

-0.17 19 CSI 06H 0.00 25 DSI 05H 0.05 27 VOL TSC 0.19 27 PCT TSC 0.19 12%

36 41 PCT AV1 0.00 30%

36 41 PCT AV2 0.00 23%

36 41 PCT AV3

-0.38 27%

36 41 PCT AV3 0.14 35%

36 36 41 PCT AV4 0.20 33%

42 DSI 03H 0.05 36 50 PCT AV1 0.00 19%

36 50 PCT AV2 0.00 18%

36 55 PCT AV1 0.00 11%

36 55 PCT AV2 0.00 20%

36 58 DSI 05H 0.00 36 63 PCT AV1 0.00 11%

36 63 PCT AV2 0.00 18%

36 63 PCT AV3 0.00 39%

36 63 PCT AV4 0.00 12%

37 24 DSI 05H 0.10 37 29 PCT AV1 0.12 16%

37 29 PCT AV2 0.00 26%

37 30 DNI 04H

-0.20 37 32 DSI 03H 0.07 37 41 PCT AV2 0.00 16%

16 of 17 1.80 1.22 0.83 2.78 1.67 1.28 2.24 1.57 0.68 4.19 1.52 6.88 1.35 0.89 0.86 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

8.01 137 1.02 145 0.29 28 0.11 98 0.08 120 2.94 1.80 2.29 4.20 3.62 0

0 0

0 0

0.25 108 1.28 1.12 0.56 1.33 0.24 0.62 1.23 5.32 0.68 0.12 0.93 2.10 1.36 0.75 0.98 0

0 0

0 65 0

0 0

0 78 0

0 30 49 0

P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 8

9 P1 6

3 P2 P2 P2 P2 P2 P1 P2 P2 P2 P2 P1 P2 P2 P2 P2 P1 P2 P2 P1 P1 P2 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 06H 06H TEH TEC TSC TSC TSC TSC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND DSI LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 37 57 02H 0.00 0.35 58 Pl TEH TEC 37 57 DSI 05H 0.05 37 57 PCT AV2 0.00 18%

37 57 PCT AV3 0.00 17%

37 57 PCT AV4 0.00 18%

38 35 DSI 02H

-0.05 38 63 DSI 03H 0.07 39 31 DSI 05H

-0.02 39 33 DSI 03H 0.07 39 45 PCT AV3 0.00 16%

39 45 PCT AV4 0.00 27%

39 48 PCT AV2

-0.78 41%

39 48 PCT AV3 0.75 21%

39 48 PCT AV3

-0.98 43%

39 48 PCT AV4

-0.12 27%

39 70 PCT AV3 0.00 27%

40 40 41 31 DSI 05H

-0.02 42 DSI 02H 0.10 31 DSI 05H 0.05 41 52 DSI 08C

-0.02 41 68 PCT AVl 0.00 11%

42 28 PCT AV3

-0.13 20%

42 29 PCT AVl

-0.10 18%

42 45 DNI 07H 0.02 42 45 DNI 08H

-0.22 42 47 PCT AVl 0.00 23%

42 47 PCT AV2

-0.03 22%

42 42 42 43 44 44 44 44 44 51 DSI 04H 0.19 55 PCT AVl 0.00 25%

55 PCT AV2 0.00 21%

64 PSI 06H 0.00 48 DSI 02H 0.02 58 PSI 06H 0.00 58 DNI 06H 0.07 59 DNI 06H 0.10 60 DNI 06H 0.07 17 of 17 0.15 1.17 1.16 1.25 0.37 0.21 0.14 0.23 1.01 2.49 5.95 1.48 6.95 2.35 2.97 65 0

0 0

35 22 86 40 0

0 0

0 0

0 0

0.14 76 0.37 165 0.23 93 0.26 0.96 1.24 1.09 2.00 1.27 1.68 1.63 0.39 38 0

0 0

38 15 0

0 32 2.01 0

1.45 0

10.17 163 0.62 147 9.79 157 1.94 15 1.96 13 1.30 10 Pl P2 P2 P2 Pl Pl Pl Pl P2 P2 P2 P2 P2 P2 P2 Pl Pl Pl Pl P2 P2 P2 Pl Pl P2 P2 Pl P2 P2 8

Pl 8

Pl Pl Pl TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Attachment C BEAVER VALLEY UNIT #2 2R17 SG EXAMINATION RESULTS 2RCS-SG21C TUBES WITH SERVICE INDUCED INDICATIONS

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21C

{TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND SCI NQI DNI LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO TSH TEC TEH 1

18 TSH

-0.07 0.14" 82° 0.11 91 P2 TSH 1

35 07C 16.70 2.57 78 6

08C 2

21 04H

-0.09 2

2 2

2 2

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

4 4

4 4

4 4

4 4

4 4

4 4

4 4

21 DNI 06H 0.03 78 DSI 03H 0.07 80 DSI 03H 0.00 84 DNI 04H

-0.01 85 DSI 03H

-0.01 4

DNI 07H 0.00 8

DSI 04H

-0.06 9

DSI 06H 0.00 16 DNI 03H 0.19 17 DNI 08H 0.00 18 DSI 03H 0.00 35 DSI 05H 0.00 39 DSI 07H 0.01 45 DSI 02H 0.00 58 DSI 02H 0.12 58 DNI 03H 0.13 60 DSI 02H 0.00 60 DSI 03H 0.03 64 DSI 02H 0.00 64 DSI 03H

-0.10 80 DSI 02H

-0.03 82 DNI 05H

-0.04 90 DSI 06H

-0.03 93 DSI 04H 0.00 94 DNI 05H

-0.01 3

DSI 04H 0.00 26 DSI 03H 0.01 32 DNI 04H 0.00 32 DNI 06H 0.00 32 DNI 08H 0.03 33 DSI 02H 0.16 34 DNI 06H 0.00 34 DNI 08H 0.00 38 DNI 05H 0.00 39 DSI 07H 0.06 39 SAl 07H 0.12 48 DSI 02H

-0.09 49 DSI 03H

-0.01 69 DSI 03H 0.00 0.23" 1 of 17 1.36 1.41 0.12 0.19 21 21 89 90 1.34 54 0.48 17 1.25 49 0.29 124 0.16 117 1.43 1.23 12 54 0.32 76 0.21 133 0.43 128 0.60 102 1.22 60 1.13 39 0.48 81 0.38 44 0.29 69 0.74 48 0.46 90 1.74 13 0.29 47 0.29 99 1.41 35 0.31 40 0.91 134 1.17 49 1.11 47 1.14 34 1.02 124 1.24 51 1.10 32 1.25 10 0.60 46 50° 0.14 116 0.20 0.60 0.34 96 65 39 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl 6

Pl Pl Pl 08H 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 07H 07H 08H TEH 08H TEH 08H TEH

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21C

{TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 4

76 DSI 03H 0.00 0.15 71 Pl 08H TEH 5

6 DSI 03H 0.00 0.65 125 Pl TEH TEC 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

6 6

6 6

6 6

6 6

6 6

6 6

6 6

7 6

DSI 04H 0.00 7

DSI 02H 0.02 7

DSI 03H 0.17 7

DNI 08H 0.22 8

DNI 08H 0.12 12 DNI 04H 0.15 14 DNI 08H 0.02 15 DSI 03H 0.02 18 DSI 02H

-0.02 18 DNI 08H 0.00 19 DSI 02H

-0.05 19 DSI 03H 0.05 22 DNI 08H 0.20 25 DNI 08H 0.00 27 DNI 08H 0.17 28 NQI 01H 13.22 29 DNI 08C 0.00 62 DSI 02H 0.07 66 DSI 03H 0.27 70 DNI 05H 0.05 71 DSI 02H 0.12 74 DNI 03H

-0.02 76 DSI 03H 0.15 86 DSI 08H 0.17 89 DSI 02H 0.17 23 DSI 02H

-0.02 30 DSI 02H 0.00 30 DSI 03H

-0.05 38 SAl TSH 0.07 50 DNI 05H 0.27 52 SAl TSH 0.21 54 DSI 03H 0.20 55 DSI 02H 0.15 63 DSI 02H 0.10 76 DNI 05H 0.15 76 DNI 07H 0.17 78 DSI 03H 0.07 84 DSI 03H 0.10 92 DSI 04H

-0.05 7

DNI 07C 0.07 0.14" 0.25" 2 of 17 0.24 0.23 0.85 1.34 1.43 1.25 1.36 0.27 0.56 1.27 0.68 0.29 1.36 1.55 1.45 2.26 1.30 87 87 82 18 17 42 33 82 89 42 72 69 11 17 15 71 39 0.19 106 0.63 67 1.31 52 0.42 61 1.32 51 0.88 74 1.14 18 0.58 81 0.46 104 0.36 129 0.39 109 53° 0.21 60 1.29 53 56° 0.18 122 0.57 101 0.17 64 0.73 110 1.29 56 1.35 53 1.00 68 0.48 81 0.32 47 2.03 12 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl 6

Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl 6

Pl 6

Pl Pl Pl Pl Pl Pl Pl Pl Pl TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC STH TEC STH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 7

7 DNI 07H 0.03 2.35 18 P1 TEH TEC 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

8 8

8 8

8 8

8 8

8 8

8 8

8 9

9 9

9 9

9 9

9 9

9 9

9 9

7 DNI 08H 0.00 9

DNI 02H 0.02 10 DNI 05H 0.02 12 DNI 02H 0.00 38 SAl TSH 0.00 40 DSI 03H

-0.02 40 DSI 04H 0.00 49 DSI 02H 0.17 49 DSI 03H 0.20 49 DNI 08H

-0.08 58 DSI 02H 0.00 59 DNI 04H 0.00 62 DNI 04H 0.12 67 DSI 02H 0.15 80 DSI 03H 0.12 2

DSI 08H 0.00 12 DNI 02H

-0.02 12 NQI 05C 25.92 15 DNI 03H 0.07 21 DNI 04H 0.12 23 DSI 02H 0.00 23 DNI 06H 0.07 24 DSI 02H

-0.07 43 DSI 03H 0.05 52 SCI TSH

-0.11 63 DSI 06H

-0.02 72 DSI 03H 0.10 84 DSI 03H 0.00 4

SCI TSH

-0.10 6

DNI 05H 0.17 20 DSI 04H 0.00 26 DSI 03H 0.05 30 DSI 02H

-0.02 30 DNI 07H 0.00 32 DSI 02H 0.12 32 DNI 07H

-0.02 35 DSI 02H 0.02 37 DSI 02H 0.07 38 DSI 03H 0.12 39 DSI 05H 0.00 41 DSI 02H 0.10 0.16" 2.08 1.36 1.33 1.30 56° 0.14 0.37 0.39 0.43 0.35 1.36 0.67 1.48 1.58 0.82 0.30 0.40 0.54 2.34 1.07 1.15 0.77 0.42 12 58 41 48 83 86 40 89 85 30' 72 50 48 18 68 31 48 81 35 20 86 19 0.61 75 0.29 53 0.19" 114° 0.17 126 0.45 80 0.40 16 0.56 75 0.18" 56° 0.11 95 3 of 17 1.25 25 0.38 158 0.54 0.35 1.25 0.72 1.42 0.95 61 94 51 51 51 94 0.39 89 0.33 97 0.34 118 0.44 105 P1 P1 P1 P1 6

P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 6

P1 P1 P1 P1 P1 P1 P2 P1 P1 P1 P2 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND DSI DSI DSI LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO TEC TEC TEC 9

44 03H 0.02 0.27 70 P1 TEH 9

45 05H 0.02 9

45 06H 0.05 9

9 9

9 9

9 47 DSI 02H

-0.09 54 DSI 02H 0.10 54 DSI 04H 0.32 65 DSI 06H 0.15 73 DNI 08H 0.00 74 DNI 06H 0.17 10 7

DNI 05H 0.17 10 8

DSI 02H

-0.05 10 9

DSI 03H 0.10 10 10 DSI 02H

-0.05 10 10 DSI 03H 0.07 10 15 DNI 07H

-0.02 10 18 DSI 04H

-0.02 10 24 DSI 03H 0.00 10 31 DNI 07H 0.03 10 32 DNI 03H 0.00 10 36 DSI 02H 0.17 10 37 DSI 02H 0.02 10 38 DSI 07H 0.00 10 43 DSI 02H 0.00 10 44 DSI 02H 0.12 10 51 DSI 02H 0.10 10 51 DSI 05H 0.12 10 51 DNI 05H 0.00 10 10 10 10 10 10 10 10 10 11 11 11 11 11 11 52 DNI 08C

-0.12 54 DSI 02H 0.10 54 DSI 03H 0.20 54 DNI 04H 0.00 72 DSI 02H 0.12 72 DSI 03H 0.12 72 DNI 07H 0.15 78 DSI 03H 0.20 89 DNI 07H 0.02 7

DSI 02H 0.00 9

DSI 03H 0.20 17 DSI 02H 0.00 17 DNI 04H 0.00 17 DNI 06H 0.00 17 DNI 07C

-0.10 4 of 17 0.50 0.30 82 64 0.66 55 0.72 136 0.90 0.61 1.39 1.58 49 48 52 53 1.17 47 0.95 93 0.42 124 0.80 88 0.53 76 0.28 18 0.23 27 0.48 96 1.28 40 1.38 20 0.22 123 0.76 96 0.34 138 0.27 85 0.40 115 1.20 40 0.82 14 1.73 47 1.25 1.07 29 80 0.99 86 1.61 53 0.46 98 0.25 55 1.37 47 0.29 152 1.26 43 0.58 58 0.65 60 1.06 80 1.99 1.39 1.37 49 56 27 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 TEH TEH STH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC STH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21C

{TUBES WITH SERVICE INDUCED INDICATIONS}

ROW COL IND LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 11 18 DNI 08C 0.00 1.57 40 P1 TEH TEC 11 11 11 11 11 11 11 36 DSI 02H

-0.15 36 DNI 04H 0.17 36 DNI 06H 0.05 42 DSI 02H 0.10 42 DNI 06C

-0.15 48 DNI 04H

-0.17 49 DSI 02H 0.17 11 49 DSI 03H 0.27 11 54 DNI 03H 0.27 11 54 DNI 06H 0.15 11 55 DNI 04H 0.02 11 59 DNI OSH 0.02 11 62 DSI 03H 0.17 11 70 DSI 03H 0.20 11 72 DSI 03H 0.10 11 76 NQI 04H 9.33 11 78 DNI 06H 0.12 11 88 DSI OSH 0.12 12 12 12 12 12 12 12 12 12 12 13 13 13 13 13 13 13 13 13 13 13 13 13 9

DSI 02H 0.05 26 DNI 02H

-0.10 30 DSI 02H 0.10 35 DSI 04H 0.07 55 DSI 02H

-0.05 70 DSI 02H 0.15 70 DSI 03H 0.00 83 DSI 03H 0.05 87 SCI TSH

-0.12 92 DNI 04H 0.02 16 NQI TSC 3.61 27 DNI 02H 0.02 30 DNI OSH 0.02 32 DSI 02H 0.15 35 DNI OSH

-0.05 35 DNI 07H 0.05 43 DSI 02H 0.10 43 DSI 03H 0.22 59 DSI 03H 0.25 63 DSI 02H 0.15 64 DSI 02H 0.15 64 DNI OSH 0.25 73 NQI 07H 20.61 0.47 1.93 1.69 1.11 1.86 1.50 0.56 80 45 43 56 18 12 58 1.05 63 1.28 44 1.47 38 1.25 54 1.25 26 0.73 22 0.55 32 0.48 45 2.36 88 1.39 38 0.54 145 0.37 1.26 0.48 0.37 0.59 0.42 0.27 0.12 0.22" 122° 0.19 61 30 73 91 60 73 86 88 69 5 of 17 1.44 54 0.49 114 1.05 54 1.26 55 0.24 1.78 52 so 1.88 35 0.35 34 0.36 126 0.33 37 0.50 34 0.54 70 1.40 25 0.67 119 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 6

P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 P1 3

P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 3

STH TEC STH TEC STH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND DNI DNI DNI DNI LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO TEC TEC TEC TEC 13 74 05H 0.20 1.52 36 P1 TEH 13 74 07H 0.02 08H

-0.02 03H

-0.20 14 27 14 27 14 14 14 27 DNI 08H 0.08 29 DSI 04H

-0.07 29 SAl 04H 0.00 14 35 DNI 07C 0.00 14 38 DSI 02H 0.20 14 39 DSI 05H 0.22 14 43 DNI 03H 0.00 14 50 DSI 02H 0.12 14 14 14 14 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 16 16 16 54 DSI 02H

-0.02 59 DSI 03H 0.07 70 DNI 04H 0.10 70 DSI 08H 0.17 3

DNI 04H 0.02 5

DSI 04H 0.02 5

5 DNI 06H 0.02 DNI 08H

-0.02 6

DNI 05H 0.00 8

DNI 05H 0.02 8

DNI 06H 0.02 8

DNI 07H 0.00 11 DNI 06H 0.00 11 DNI 07H 0.05 14 DSI 03H 0.02 14 DNI 07H 0.00 35 DSI 02H

-0.02 35 DSI 03H

-0.05 38 DSI 04H 0.12 38 SAl 04H

-0.18 39 DSI 02H 0.17 39 DSI 03H 0.07 43 DNI 08C

-0.30 61 DSI 02H 0.15 62 DSI 02H 0.15 80 DSI 03H 0.15 87 DSI 03H 0.15 15 DSI 03H 0.15 15 DNI 07H 0.05 15 DNI 08H 0.02 1.48 1.22 1.27 1.19 0.18 36 24 12 26 69 0.20" 180° 0.10 101 0.30" 6 of 17 1.27 31 0.43 75 0.39 61 1.37 35 0.85 112 0.70 0.42 1.29 0.22 1.20 0.48 1.30 1.26 1.34 1.40 1.40 1.33 1.26 1.05 0.43 1.34 0.23 0.44 0.45 40° 0.18 0.58 0.71 1.39 0.39 0.25 0.29 0.33 0.65 1.19 1.28 67 62 52 42 58 46 64 50 42 53 56 54 49 52 37 55 83 81 47 74 77 87 19 64 57 53 82 74 55 47 P1 P1 P1 P1 P1 6

P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 6

P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 TEH TEH TEH TEH TEC TEH TEC 04H 05H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 04H 04H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 16 16 DNI 06H 0.05 2.02 44 P1 TEH TEC 16 16 16 16 16 16 16 16 16 16 16 16 16 16 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 DSI 02H

-0.05 23 DNI 06C

-0.15 23 DNI 07C

-0.02 34 DNI 03H 0.10 36 SCI TSH

-0.08 45 DNI 05H 0.22 46 DNI 03H 0.17 46 DSI 04H 0.15 46 DNI 06H 0.00 55 DSI 06H 0.02 57 DSI 03H 0.15 63 DSI 02H 0.12 73 DSI 02H 0.20 76 SCI TSH

-0.08 9

DSI 04H 0.00 9

SAl 04H

-0.09 14 DSI 04H 0.17 17 DSI 02H

-0.07 18 DSI 02H

-\\).05 24 DSI 04H 0.00 26 DSI 03H 0.00 27 DNI 08C 0.02 35 DSI 03H

-0.05 35 DNI 06H 0.02 35 DNI 07H 0.03 35 SAl 03H

-0.01 36 SCI TSH

-0.08 37 DNI 04H

-0.07 43 DSI 02H

-0.07 48 DSI 02H 0.00 49 DSI 02H 0.07 50 DSI 03H 0.12 50 SAl 03H

-0.03 58 DNI 03H 0.27 59 DNI 03H 0.15 60 DNI 05H 0.02 61 DSI 02H 0.12 61 DSI 03H 0.15 63 DSI 02H 0.15 66 DSI 02H 0.15 67 DSI 02H 0.10 0.35 1.27 1.39 35 19 31 1.24 53 0.18" 100° 0.19 118 1.55 14 1.62 43 0.74 47 1.41 55 0.58 148 0.44 49 0.27 37 0.65 113 0.20" 47° 0.12 100 0.36 40 0.20" 180° 0.08 110 0.28" 0.14" 0.23" 7 of17 0.25 0.20 0.37 0.12 46 44 42 90 0.19 106 1.26 0.90 27 45 1.41 45 1.23 55 50° 0.08 91 43° 0.12 121 1.37 38 0.78 129 0.70 44 0.57 0.59 58° 0.13 75 89 58 1.54 45 1.33 56 1.25 56 1.03 54 0.45 100 0.77 69 0.58 111 0.65 113 P1 P1 P1 P1 P2 P1 P1 P1 P1 P1 P1 P1 P1 P2 P1 6

P1 P1 P1 P1 P1 P1 P1 P1 P1 6

P2 P1 P1 P1 P1 P1 6

P1 P1 P1 P1 P1 P1 P1 P1 TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC 04H 04H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 03H 03H TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 03H 03H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 17 68 DSI 02H 0.00 0.35 80 P1 TEH TEC 17 68 DNI 07H

-0.02 1.44 45 P1 TEH TEC 18 6

DNI 08H 0.00 1.38 36 P1 TEH TEC 18 18 18 18 18 18 18 18 18 18 18 18 8

DNI 08H

-0.02 12 DNI 02H 0.15 15 DNI 02H 0.17 15 DSI 06H 0.20 15 DNI 08C

-0.20 15 DNI 08H 0.19 30 DNI 03H 0.00 30 DNI 05H 0.00 30 DNI 07H 0.02 37 DNI 04H

-0.12 38 DSI 02H

-0.05 38 SCI TSH

-0.09 18 47 DSI 03H 0.22 18 48 DSI 02H 0.22 18 48 DSI 03H 0.00 18 48 DSI 04H 0.05 18 50 DSI 02H 0.17 18 51 DSI 02H 0.12 18 51 DNI 04H 0.10 18 52 DNI 06H 0.00 18 53 DSI 02H 0.10 18 53 DNI 03H 0.17 18 53 DNI 04H 0.00 18 54 DSI 02H 0.02 18 54 DSI 03H 0.05 18 54 DNI 06H 0.07 18 55 DSI 02H 0.07 18 62 DSI 02H 0.10 18 62 DSI 03H 0.27 18 62 DSI 04H 0.17 18 67 DSI 02H 0.12 18 67 DSI 03H 0.22 18 18 18 18 19 19 19 73 DSI 03H 0.17 77 NQI 05C 34.59 88 DNI 04H 0.00 90 DNI 07H 0.15 20 DNI 02H

-0.20 20 DNI 04H 0.00 20 DNI 05H 0.27 0.07" 8 of17 1.27 1.40 1.66 41 39 38 0.17 102 1.55 1.57 1.25 1.28 1.26 1.34 0.50 37 41 45 53 41 18 85 22° 0.09 103 0.70 58 0.98 161 0.74 61 0.80 46 0.32 64 0.81 90 1.23 73 1.25 55 0.86 59 1.26 68 1.41 52 0.67 57 0.71 64 1.42 36 0.66 86 0.58 92 0.53 102 0.27 92 0.76 82 0.56 57 0.31 37 0.62 116 1.34 56 1.31 27 1.93 24 1.21 22 1.25 18 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 3

P1 P1 P1 P1 P1 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND DNI DNI LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO TEC TEC 19 23 06C 0.00 1.30 27 P1 TEH 19 25 04H 0.02 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 21 21 26 DSI 03H

-0.05 29 DSI 02H

-0.02 29 DNI 08H 0.00 34 DNI 07H 0.00 38 DSI 02H 0.20 38 DSI OSH 0.12 38 SAl 02H

-0.23 38 SAl 02H 0.35 47 DNI 04H 0.12 48 DSI 02H 0.00 48 DSI 03H 0.10 54 DSI 02H 0.02 57 DSI 04H 0.17 57 DSI OSH 0.10 57 DNI 07H 0.00 74 DNI 07H 0.15 79 DSI 02H 0.00 13 DNI OSH 0.12 13 DNI 06H 0.15 13 DNI 07C 0.00 13 DNI 07H 0.15 17 DNI 07H 0.15 75 DSI 02H

-0.07 75 NQI 06C 13.87 75 DNI 07H 0.03 75 NQI 07H 22.84 76 DSI 02H

-0.05 76 DSI 03H 0.20 76 DNI 06H 0.00 76 SAl 02H 0.16 78 DNI 08H 0.03 80 DNI 06H 0.02 80 DNI 07H 0.00 82 DNI OSH 0.00 83 DNI 07H 0.00 84 DNI 04H 0.05 85 DSI 03H 0.02 88 DNI 03H 0.12 10 DNI OSH 0.02 18 DSI 02H 0.05 0.23" 0.25" 0.29" 9 of 17 1.43 50 0.31 109 0.43 92 1.44 46 1.25 33 0.62 52 1.05 51 48° 0.15 114 50° 0.25 101 1.43 53 0.61 54 0.74 54 0.43 60 0.51 32 0.71 62 1.35 40 1.30 44 0.81 118 1.29 49 1.28 46 1.26 34 1.48 41 1.39 42 0.50 110 0.63 93 1.41 55 0.58 49 0.75 128 1.01 1.47 34° 0.13 71 57 97 1.27 50 1.21 53 1.12 51 1.12 51 1.34 45 1.78 43 0.24 104 1.27 61 1.27 32 0.34 140 P1 P1 P1 P1 P1 P1 P1 6

6 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 3

P1 3

P1 P1 P1 6

P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 TEH TEH TEC STH TEC STH TEC TEH TEC TEH TEC TEH TEC 02H 02H 02H 02H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC STH TEC STH TEC STH TEC STH TEC TEH TEC TEH TEC TEH TEC 01H 02H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 21 18 DSI 03H 0.07 0.37 126 P1 TEH TEC 21 18 DNI 08H 0.00 1.24 44 P1 TEH TEC 21 21 21 21 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 23 23 23 23 23 23 23 23 23 23 23 23 23 25 DSI 04H 0.05 31 DNI 06H 0.05 62 DSI 02H 0.05 67 DSI 07H 0.00 9

DNI 07H

-0.02 15 DNI OSH 0.17 18 DSI 02H 0.02 18 DNI 06H 0.02 20 DSI 02H 0.10 20 DNI 07H 0.15 20 DNI 08H 0.03 21 DNI OSH 0.00 21 DNI 06H 0.02 24 DSI 03H

-0.07 30 DNI 03H 0.07 33 DSI 02H

-0.02 36 DNI 04H 0.00 39 DNI 08H

-0.03 61 DSI 03H 0.15 64 DSI 03H 0.15 72 DNI OSH 0.15 73 DNI OSH 0.00 74 DNI 03H 0.05 74 DNI 04H 0.02 74 DNI OSH 0.17 75 DNI 07C 0.00 77 DSI 03H

-0.05 10 DSI 02H 0.05 10 DNI OSH 0.02 28 DSI 03H 0.10 28 DNI 07H

-0.02 35 DNI 04H 0.05 37 DSI 02H

-0.05 39 DSI 02H 0.00 39 DSI OSH

-0.02 39 DNI 07H 0.00 42 DSI 02H 0.20 42 DSI 03H 0.10 43 DNI OSH 0.10 43 DNI 06H 0.12 10 of 17 0.11 66 1.38 36 0.41 67 0.48 165 1.28 1.39 0.43 1.32 0.94 1.77 1.37 1.62 1.70 0.40 1.31 0.51 1.30 1.37 42 34 85 57 91 38 45 53 46 94 39 41 25 40 0.27 69 0.28 153 1.29 so 1.31 51 1.30 52 1.57 43 1.40 25 1.35 30 0.17 124 0.47 35 1.34 0.51 1.26 1.25 0.83 0.52 0.56 1.25 0.34 0.67 1.26 1.53 51 80 34 42 60 97 51 so 43 76 46 43 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND DSI DSI DNI DNI DNI LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO TEC TEC TEC TEC TEC 23 69 03H 0.17 0.37 36 Pl TEH 23 77 02H 0.12 24 11 05H 0.15 24 13 04H 0.29 24 19 07H 0.15 24 24 24 24 34 DNI 03H 0.05 34 DNI 05H 0.25 34 DSI 08H

-0.02 35 DNI 07C

-0.05 24 41 DSI 02H 0.12 24 41 DSI 04H 0.17 24 41 SAl 04H 0.02 24 41 SAl 04H 0.01 24 24 24 24 24 24 24 24 24 24 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 48 DSI 03H 0.27 49 DNI 07H 0.00 50 DSI 02H 0.12 56 DSI 03H 0.30 57 DSI 02H 0.15 60 SCI TSH

-0.06 61 DSI 02H 0.25 63 DSI 04H 0.00 84 PCT TSC 0.06 30%

84 VOL TSC 0.06 14 DNI 06H 0.00 17 DSI 03H 0.02 26 DSI 04H 0.02 29 DSI 03H

-0.02 29 DNI 04H 0.10 31 DSI 02H 0.05 33 DNI 04H 0,.00 33 DSI 08H

-0.10 34 DSI 02H 0.15 34 DSI 03H 0.17 34 DSI 05H 0.05 37 DNI 07H

-0.02 38 DNI 06H 0.00 47 DSI 03H 0.02 47 DNI 04H 0.20 47 DNI 06H 0.02 47 DSI 08H 0.03 54 DSI 02H 0.12 60 DSI 02H 0.10 0.31" 0.13" 0.12" 11 of 17 0.40 1.50 1.37 1.29 1.80 1.51 0.48 1.52 80 53 17 47 44 43 34 15 1.19 128 0.47 94 64° 0.23 92 37° 0.09 117 1.23 66 1.26 52 0.43 69 0.80 111 0.34 45 90° 0.13 117 0.66 81 0.36 31 0.26 103 0.26 102 1.26 30 0.35 82 0.13 0.51 1.43 0.53 1.31 0.57 92 35 51 81 43 49 1.16 73 1.04 102 1.04 1.36 1.32 0.85 1.33 1.26 0.81 0.37 0.32 47 33 48 34 47 48 15 49 90 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl 6

6 Pl Pl Pl Pl Pl P2 Pl Pl 3

3 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl TEH TEH TEH TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 04H 04H 04H 04H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TSC TSC TSC TSC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS}

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 25 61 DSI 02H 0.17 0.60 99 P1 TEH TEC 25 25 25 25 25 25 25 61 DNI 05H 0.00 62 DSI 04H 0.05 64 DNI 08H 0.07 65 DSI 02H 0.10 65 DNI 07H

-0.07 74 DSI 02H 0.12 74 SAl 02H 0.04 25 75 DNI 07H 0.00 25 75 DNI 08H 0.00 25 76 DSI 02H 0.10 25 76 DSI 05H 0.00 25 79 DSI 02H 0.05 25 79 DNI 04H 0.00 25 79 DNI 08H 0.00 26 17 DNI 03H 0.02 26 17 DNI 05H 0.30 26 17 DNI 06H 0.32 26 19 DNI 08H 0.15 26 26 24 DSI 06H 0.00 26 DTI TEC 16.43 26 30 DNI 07H 0.17 26 38 DSI 05H 0.09 26 39 DSI 05H 0.00 26 42 DSI 02H 0.00 26 44 DSI 06H 0.15 26 45 DNI 06H 0.32 26 60 DNI 04H 0.00 26 65 DSI 03H 0.05 26 70 DSI 03H 0.29 26 72 DSI 08H 0.05 27 12 DNI 04H 0.15 27 16 DNI 04H 0.00 27 17 DNI 04H 0.20 27 20 DSI 02H 0.00 27 20 DNI 03H 0.15 27 27 27 27 27 27 20 DNI 05H 0.00 20 DNI 08H 0.00 21 DNI 02H

-0.07 21 DNI 04H

-0.15 22 DSI 02H 0.15 23 DNI 07H 0.00 0.28" 12 of 17 1.27 36 0.48 134 1.74 25 0.66 1.27 97 44 0.31 117 26° 0.08 127 1.51 50 1.40 50 0.71 96 0.30 107 0.34 98 1.67 54 1.53 41 1.69 23 1.41 24 1.80 18 1.18 30 0.33 10 6.50 156 1.67 22 0.66 23 0.95 59 0.47 33 0.26 51 1.46 18 1.41 48 0.25 130 1.20 94 0.59 30 1.44 41 1.38 53 1.41 26 0.62 78 1.31 47 1.57 1.40 1.80 1.50 0.37 1.40 56 51 16 14 72 57 P1 P1 P1 P1 P1 P1 6

P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 02H 02H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND DNI DSI DSI DNI LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO TEC TEC TEC TEC 27 23 08H 0.00 1.36 55 Pl TEH 27 24 04H 0.05 0.35 25 Pl TEH 27 30 02H 0.07 0.68 22 Pl TEH 27 30 08H 0.08 27 27 27 27 27 27 27 27 27 27 31 DNI OSH 0.15 31 DNI 06H 0.02 35 DNI 04H 0.05 35 DNI 07H 0.03 60 DSI 02H 0.22 69 DSI 02H 0.00 76 DSI 03H 0.17 82 NQI 02C 46.52 82 NQI AVl 5.68 84 NQI 02C 25.54 28 10 DNI 04H 0.00 28 11 DNI 03H 0.02 28 11 DNI 04H 0.00 28 18 DNI OSH 0.15 28 21 DNI 04H 0.12 28 23 DNI OSH 0.02 28 23 DNI 07H 0.03 28 27 DSI OSH 0.02 28 27 DNI 08H 0.06 28 29 DNI 03H 0.15 28 35 DSI 02H 0.02 28 35 DNI 07H

-0.02 28 35 DNI 08H 0.02 28 37 DNI OSH 0.12 28 37 DNI 07H 0.05 28 42 DSI 02H 0.20 28 42 DSI 04H 0.17 28 44 DSI 02H 0.00 28 50 DSI 03H 0.12 28 50 DNI 08H 0.15 28 73 DSI 03H

-0.02 28 75 DNI 04H 0.00 28 81 DNI OSH 0.00 28 29 29 29 29 85 DSI 02H 0.00 11 DNI 04H 0.17 11 DSI OSH 0.25 20 DNI 08H 0.18 25 DNI 06H

-0.02 13 of 17 1.63 1.25 1.50 1.60 1.73 0.74 22 53 51 52 35 66 0.33 112 0.59 56 3.19 78 0.76 106 0.40 101 1.33 48 1.29 43 1.48 35 1.47 38 1.23 27 1.24 38 1.29 33 0.24 111 1.38 30 1.41 15 0.89 93 1.52 1.36 1.45 1.60 0.36 0.33 0.43 0.29 1.52 0.23 1.76 1.34 47 47 36 43 63 27 53 97 38 47 22 52 0.39 101 1.41 30 0.46 73 1.87 11 1.64 40 Pl Pl Pl Pl Pl Pl Pl Pl 6

3 3

Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 29 26 DSI 05H 0.20 0.75 67 P1 TEH TEC 29 29 29 29 29 29 29 29 29 29 29 29 29 29 29 29 29 29 29 29 29 29 29 29 29 30 30 30 30 30 30 28 DNI 08H 0.02 29 DSI 03H 0.15 29 DNI 04H 0.02 29 DNI 05H 0.05 29 DNI 08H 0.00 35 DNI 06H 0.02 35 DNI 07H

-0.10 37 DSI 02H 0.05 37 DNI 08H 0.00 38 DSI 05H 0.12 39 DNI 06H 0.02 43 DSI 03H 0.15 43 DNI 06H 0.12 43 DNI 08H 0.07 45 DNI 07H

-0.02 47 DSI 02H 0.15 47 DNI 07H 0.18 48 DSI 05H 0.17 48 DNI 06C

-0.22 49 DNI 07H 0.00 57 DSI 05H 0.17 63 DSI 05H 0.27 66 DNI 04H 0.17 66 DNI 06H 0.00 73 DNI 03H 0.10 12 DSI 03H 0.02 24 DSI 02H 0.00 24 DNI 08H 0.00 25 DSI 04H 0.07 31 DSI 03H

-0.02 31 DSI 04H 0.07 30 41 DSI 02H 0.12 30 43 DNI 08H 0.02 30 58 DNI 08H 0.13 30 60 DSI 02H 0.10 30 61 DSI 02H 0.17 30 61 DSI 04H 0.20 30 61 SAl 04H 0.04 30 30 30 63 SCI TSH

-0.05 63 DSI 04H 0.17 63 DNI 07H 0.02 1.26 0.~6 1.27 1.22 1.27 1.29 1.53 39 84 70 56 44 33 13 0.45 48 1.43 34 0.65 63 1.26 43 0.32 125 1.29 52 1.32 1.38 36 41 1.02 97 1.18 53 0.26 134 1.26 1.29 0.32 10 46 42 0.78 68 1.53 50 1.27 51 1.33 41 0.25 44 0.43 83 1.36 50 0.17 103 0.48 51 0.33 61 0.24 118 1.34 38 1.44 34 0.68 70 0.60 63 0.38 78 0.29" 104° 0.10 128 0.30" 14 of 17 79° 0.18 0.78 1.35 76 24 51 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 6

P2 P1 P1 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC STH TEC TEH TEC TEH TEC TEH TEC 04H 04H TSH TSH TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21C

{TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO DNI NQI PCT VOL DSI DSI DSI NQI DSI LOC INCH %TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO TEC TEC 07H 07H TEC TEC TEC TEC TEC 30 66 06H 0.15 1.32 68 Pl TEH 30 77 06H 40.16 30 77 06H 40.16 18%

06H 40.16 30 77 31 14 05H 0.00 31 17 04H 0.05 31 22 02H 0.00 31 24 OSH 39.09 04H

-0.05 31 29 31 31 DNI OSH 0.07 31 31 DNI 07H 0.00 31 35 DNI 08H 0.02 31 37 DNI 03H 0.02 31 37 DNI 04H 0.02 31 37 DNI 08H 0.00 31 47 DNI 07H 0.15 31 49 DSI 02H 0.12 31 60 DSI 02H 0.12 31 61 DSI 03H 0.17 31 31 31 31 31 31 31 31 31 31 31 32 32 32 32 32 32 32 32 32 32 32 32 62 DNI 07H 0.17 64 DSI 04H 0.17 64 SAl 04H

-0.02 66 DSI 02H 0.15 66 DSI OSH 0.20 75 DSI 02H 0.00 75 DNI 07H 0.02 75 SAl 02H 0.02 77 DSI 06H 0.05 80 NQI 02C 12.71 81 DSI 02H 0.07 19 DSI OSH

-0.05 25 DSI 03H 0.07 35 DNI 08H 0.04 40 NQI 02H 20.70 40 NQI OSC 8.61 47 DNI 04H 0.12 47 DNI 06H 0.05 47 DNI 08H 0.12 51 DNI 04H

-0.05 63 DSI 03H 0.07 63 DNI 06H 0.00 63 SAl 03H 0.09 0.37" 0.29" 0.24" 15 of 17 0.29 111 0.12 80 0.14 0.27 0.30 0.34 77 94 41 63 0.65 135 0.30 129 1.43 1.32 1.38 1.33 1.20 1.74 1.35 0.52 0.35 0.54 33 42 32 36 38 21 37 65 68 54 1.26 49 0.61 32 66° 0.13 129 0.59 110 0.46 45 0.21 103 1.25 so 55° 0.10 101 0.30 72 0.45 41 1.27 108 0.15 77 0.27 41 1.45 40 0.51 100 0.40 121 1.08 1.71 1.49 1.87 0.34 1.28 51° 0.16 36 17 22 19 44 48 89 3

3 6

Pl Pl Pl 3

Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl 6

Pl Pl Pl Pl 6

Pl 3

Pl Pl Pl Pl 3

3 Pl Pl Pl Pl Pl Pl 6

TEH 06H 06H TEH TEH TEH TEH TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 04H 04H TEH TEC TEH TEC TEH TEC TEH TEC 02H 02H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 03H 03H

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS}

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 32 73 DNI 07H 0.00 1.44 50 P1 TEH TEC 32 33 33 33 33 33 34 34 34 34 34 34 34 75 DNI 06H 0.00 34 DSI 06H 0.17 43 DNI 04H 0.02 50 DNI OSH 0.12 60 DSI 07H 0.20 73 DNI OSH 0.00 24 DSI 07H 0.03 26 DSI 02H 0.05 39 DSI OSH

-0.02 47 DNI 07H 0.15 49 DNI 07H 0.18 55 DSI 03H

-0.07 58 DSI 02H 0.15 34 58 DSI OSH 0.12 34 59 DSI 02H 0.05 35 22 DSI 02H

-0.02 35 26 DNI 07H 0.15 35 34 DSI 03H 0.02 35 34 DSI 04H

-0.07 35 38 DSI 07H

-0.05 35 39 DNI 07H 0.00 35 53 DSI 06H 0.02 36 20 DSI 03H 0.12 36 26 DSI OSH 0.22 36 27 DSI OSH 0.02 36 53 DSI 02H 0.00 36 53 SAl 02H 0.06 36 58 DNI 06H 0.10 36 58 DNI 07H 0.17 37 23 DNI 03H 0.17 37 26 DSI OSH

-0.05 37 37 37 37 37 38 39 39 40 40 27 DNI 04H 0.22 35 DSI 03H 0.00 52 DSI 06H 0.20 67 PCT AV2 0.00 24%

67 PCT AV3 0.00 30%

42 DSI OSH 0.20 24 NQI 04C 43.62 27 DSI 04H 0.00 25 DSI 03H 0.05 38 DNI 06H 0.00 0.38" 16 of 17 1.39 0.33 1.27 1.32 0.23 1.34 0.21 1.41 0.25 1.15 1.13 0.16 0.62 0.30 0.76 0.35 1.57 0.32 0.16 0.43 1.16 0.19 55 16 so 36 78 45 53 11 80 so so 94 97 59 71 85 18 49 78 56 49 96 0.72 139 0.66 67 0.45 75 0.97 154 24° 0.10 122 1.63 44 1.23 47 1.34 28 0.09 141 0.99 0.34 0.18 1.96 2.96 54 43 49 0

0 0.24 59 0.79 114 0.46 0.23 1.28 30 58 57 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 6

P1 P1 P1 P1 P1 P1 P1 P2 P2 P1 3

P1 P1 P1 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 02H 02H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R17 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 40 39 DSI 03H 0.07 0.24 32 P1 TEH TEC 40 53 DSI 04H 0.05 0.67 137 P1 TEH TEC 41 27 DSI 04H 0.02 0.28 so P1 TEH TEC 41 40 NQI 07H 43.90 0.37 105 3

TEH TEC 41 40 NQI 07H 39.70 0.70 138 3

TEH TEC 41 44 DSI 04H 0.22 0.18 132 P1 TEH TEC 41 so DSI 08H 0.07 0.14 66 P1 TEH TEC 42 32 DSI 04H

-0.07 0.25 60 P1 TEH TEC 17 of 17