Category:NUREG
MONTHYEARML18220B3142018-08-27027 August 2018 OEDO-18-00160 - Acknowledgement Letter 2.206 Petition for Citizen Complaint and Request for Enforcement Action Regarding Firstenergy Nuclear Facility Operations in Ohio and Pennsylvania ML16104A3502016-04-30030 April 2016 NUREG-2193, Suppl 1, Safety Evaluation Report Related to the License Renewal of Davis-Besse Nuclear Power Station. Docket Number 50-346, Firstenergy Nuclear Operating Company. ML16104A3012016-04-30030 April 2016 NUREG-2193, Vol. 2, Safety Evaluation Report Related to the License Renewal of Davis-Besse Nuclear Power Station. Docket Number 50-346, Firstenergy Nuclear Operating Company Sections 4 to 6 Appendices. ML16104A2072016-04-30030 April 2016 NUREG-2193, Vol. 1, Safety Evaluation Report Related to the License Renewal of Davis-Besse Nuclear Power Station Docket Number 50-346 Firstenergy Nuclear Operating Company Sections 1 to 3. ML15209A8702015-07-31031 July 2015 NUREG-1437, Supp. 46, Vol. 2 Final, Generic Environmental Impact Statement for License Renewal of Nuclear Plants Supplement 46 Regarding Seabrook Station Final Report Appendices. ML15112A0982015-04-30030 April 2015 NUREG-1437, Supp 52 Vol 1, Final Generic Environmental Impact Statement for License Renewal of Nuclear Plants Supplement 52 Regarding Davis-Besse Nuclear Power Station Final Report Chapters 1 to 12 ML15113A1872015-04-30030 April 2015 NUREG-1437 Supp 52 V2 Generic Environmental Impact Statement for License Renewal of Nuclear Plants, Regarding Davis-Besse Nuclear Power Station. Final Report ML14289A0652014-10-31031 October 2014 NUREG/CR-7153, Vol. 1, Vol 4 Errata Expanded Materials Degradation Assessment (Emda) ML14050A2902014-02-28028 February 2014 NUREG-1437, Supp 52 Dfc, Generic Environmental Impact Statement for License Renewal of Nuclear Plants Regarding Davis-Besse. ML14038A1192014-02-28028 February 2014 NUREG/KM-0005 2002 Davis-Besse Reactor Pressure Vessel Head Degradation Knowledge Management Digest ML13113A1742013-04-30030 April 2013 NUREG-1437 Supp 46 Dfc #2 Generic Environmental Impact Statement for License Renewal of Nuclear Plants: Regarding Seabrook Station (Second Draft Report for Comment) ML11213A0242011-07-31031 July 2011 NUREG-1437 Supp 46 Dfc (1 of 2) Generic Environmental Impact Statement for License Renewal of Nuclear Plants: Regarding Seabrook Station (Draft for Comment) ML11213A2032011-07-31031 July 2011 NUREG-1437 Supp 46 Dfc (2 of 2) Generic Environmental Impact Statement for License Renewal of Nuclear Plants: Regarding Seabrook Station (Draft for Comment) ML0635203662006-11-30030 November 2006 NUREG/CR-6921, (1:2) Cover - Page 32, Crack Growth Rates in a PWR Environment of Nickel Alloys from the Davis-Besse and V. C. Summer Power Plants, Argonne National Laboratory. 2018-08-27
[Table view] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 NUREG/CR-7153, Volume 1 - Expanded Materials Degradation Assessment (EMDA):
Executive Summary of EMDA Process and Results NUREG/CR-7153, Volume 4 - Expanded Materials Degradation Assessment (EMDA): Aging of Concrete and Civil Structures Page 26 in Volume 1 and Page 86 in Volume 4 incorrectly state that there is operational experience indicating the occurrence of alkali-silica reactions in the containment at the Davis Besse Nuclear Power Station. The correct plant should be Seabrook Nuclear Power Plant.
The corrected sentences should read as follows:
Though this degradation is well documented by the operating experience (for bridges and dams in particular) and scientific literature, its high ranking in the EMDA analysis describes the need to assess its potential consequences on the structural integrity of the containment, considering the recent operating experience at Seabrook and other plants.