Entergy Nuclear Operations, Inc.

Pilgrim Nuclear Power Station 600 Rocky Hill Road Plymouth, MA 02360 David E. Noyes, Director Regulatory & Performance Improvement LETTER NUMBER 2.14.052 July 2, 2014 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001

SUBJECT:

Special Report - Technical Specification Table 3.2.F, Inoperable Containment High Range Radiation Instrument Channel Pilgrim Nuclear Power Station Docket No. 50-293 License No. DPR-35

Dear Sir or Madam:

This special report is submitted in accordance with Pilgrim Station's Technical Specifications Table 3.2.F, "Surveillance Instrumentation", Note 7. Note 7 requires the submittal of a special report if the "Minimum Number of Operable Instrument Channels" is not met for a surveillance instrument parameter for a period exceeding 7 days.

Containment High Radiation (Drywell) Channel "B" Instruments RIT-1001-606B and RR-1001-606B were removed from service to perform an upgrade modification on June 19, 2014. The installation of the modification took longer than planned. The modified Containment High Radiation (Drywell)

Channel "B" Instrument RIT-1001-606B failed post work testing on June 28, 2013. Troubleshooting of the instrument determined that the connector for the detector to high voltage power supply cable needed to be replaced. Re-performance of the post work testing of the Containment High Radiation (Drywell) Channel "B" Instrument RIT-1001-606B is currently scheduled for July 3, 2014.

The Containment High Radiation (Drywell) Channel "A" Instruments are operable.

This letter contains no regulatory commitments.

If you have any questions or require additional information, please contact me at (508) 830-7800.

Sincerely, David E.4oyes Director, Regulatory and Performance Improvement DEN/mew

Letter 2.14.052 Page 2 of 2 cc:

Mr. William M. Dean Regional Administrator, Region 1 U. S. Nuclear Regulatory Commission 2100 Renaissance Boulevard, Suite 100 King of Prussia, PA 19406-1415 Ms. Nadiyah Morgan, Project Manager Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission One White Flint North Mail Stop O-8C2A 11555 Rockville Pike Rockville, MD. 20852 NRC Senior Resident Inspector Pilgrim Nuclear Power Station