NRC-14-0024, Inservice Inspection Summary Report

From kanterella
(Redirected from ML14183B531)
Jump to navigation Jump to search

Inservice Inspection Summary Report
ML14183B531
Person / Time
Site: Fermi DTE Energy icon.png
Issue date: 07/02/2014
From: Conner J
DTE Electric Company
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NRC-14-0024
Download: ML14183B531 (5)


Text

i e Prside DTE Energy Copn 6400 N. Dixie HighwayNewport, IM, 48166 Tel 734.586.4849 Fax: 734586.529,5 Email connr@dteenry com July 2, 2014 10 CFR 50.55a NRC-14-0024 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington D C 20555-0001

Reference:

Fermi 2 NRC Docket No. 50-341 NRC License No. NPF-43

Subject:

Inservice Inspection Summary Report Enclosed is the Summary Report of the Inservice Inspection (ISI) activities performed at DTE Electric Company's (DTE) Fermi 2 Nuclear Power Plant during the 16 th Refueling Outage in Spring 2014. This report represents a partial summary of the ISI activities for the third Ten-Year Inspection Interval that began on May 2, 2009 and is scheduled for completion on May 1, 2019.

This report is being submitted in accordance with Code Case N532-4 on the Form OAR-1, Owner's Activity Report.

Should you have any questions or require additional information, please contact Mr. Zackary W. Rad of my staff at (734) 586-5076.

Sincerely,

Enclosure:

Form OAR-1 Owner's Activity Report cc:

NRC Project Manager NRC Resident Office Reactor Projects Chief, Branch 5, Region III Regional Administrator, Region III M. Wilson - Authorized Nuclear Inservice Inspector (ANII)

Michigan Public Service Commission Regulated Energy Division (kindschl@michigan.gov)

M. Moore - Chief Inspector Michigan Department of Labor & Economic Growth Bureau of Construction Codes and Fire Safety - Boiler Division

Enclosure to NRC-14-0024 Fermi 2 NRC Docket No. 50-341 Operating License No. NPF-43 Form OAR-1 Owner's Activity Report

Fermi Nuclear Power Station Form OAR-1 Owner's Activity Report Report Number RF-16 OAR-1 Plant Fermi NPP 6400 North Dixie Hwy, Newport, MI 48166 (Name and Address of Plant)

Unit No.

2 Commercial Service Date 1/23/1988 Refueling Outage No. 16 (if applicable)

Current Inspection Interval Third (1st, 2nd, 3rd, 4th, other)

Current Inspection Period Second (1st, 2nd, 3rd)

Edition and Addenda of Section XI applicable to the inspection plans 2001 Edition with 2003 Addenda Date and Revision of inspection plans 10/10/2013, Revision 8 Edition and Addenda of Section XI applicable to repair/replacement activities, if different than the inspection plans Code Case used:

N-460, 532-4, 586-1, 613-1, 648-1, 685, 686-1,702 (If applicable)

CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repair/replacement ac ivities and evaluations supporting the completion of RF-16 conform to the require e t-o Sec' n XI.

(Refueling Outage Number)

Signed Marc A. Brooks Program Owner Date

__/_

Owners or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by HSB CT of One State St., Hartford CT have inspected the items described in this Owner's ActivityReport, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluation described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions NB9486, M1610, A B IN N S Inspector's Signature National Board, State, Province, and Endorsements Date

/

//

AO/

6/4/2014 ScheduleWorks V. 8.1 Page 1 - 1

RF16 Owners Activity Report Attachment TABLE 1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Category and Item Number Item Description Evaluation Description None RF16 OAR-1 Attachment Page 1

RF16 Owners Activity Report Attachment TABLE 2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code t iem Description Date Completed Repair/

Class Description Of Work (Report Signed Off by Replacement ANI Inspector)

Plan Number 1

Feedwater Piping Grinding removal of linear 5/21/2014 Plan 14- 012 Integral indication associated with and Work Attachment Weld an original construction arc Order in the Drywell strike (CARD 14-21286) 37909435 SW-N21-2336-20WE 3

Residual Heat Temporary overlay repair of 2/19/2014 Plan 14-001 Removal Service service water leak (CARD 14-and Work Water Division 2 20240) using ASME Code Order Piping in the Torus Case N661-1 37904983 Room MK-E11-3184-21 3

Residual Heat Replaced elbow on spool 5/12/2014 Plan 14-003 Removal Service piece MK-E11-3184-21 due and Work Water Division 2 to a service water leak Order Piping in the Torus (CARD 14-20240) following 37904983 Room temporary overlay repair MK-E11-3184-21 using ASME Code Case N661-1 accomplished under Section XI Replacement Plan 14-001 RF16 OAR-1 Attachment Page 2