8 TRANSIT-DEPENDENT AND SPECIAL FACILITY EVACUATION TIME ESTIMATES This section details the analyses applied and the results obtained in the form of evacuation time estimates for transit vehicles. The demand for transit service reflects the needs of three population groups: (1) residents with no vehicles available; (2) residents of special facilities such as schools, medical facilities, and correctional facilities; and (3) homebound special needs population.
These transit vehicles mix with the general evacuation traffic that is comprised mostly of "passenger cars" (pc's). The presence of each transit vehicle in the evacuating traffic stream is represented within the modeling paradigm described in Appendix D as equivalent to two pc's.
This equivalence factor represents the longer size and more sluggish operating characteristics of a transit vehicle, relative to those of a pc.
Transit vehicles must be mobilized in preparation for their respective evacuation missions.
Specifically:
Bus drivers must be alerted They must travel to the bus depot They must be briefed there and assigned to a route or facility These activities consume time.
It is estimated that bus mobilization time will average approximately 90 minutes extending from the Advisory to Evacuate, to the time when buses first arrive at the facility to be evacuated.
During this mobilization period, other mobilization activities are taking place. One of these is the action taken by parents, neighbors, relatives and friends to pick up children from school prior to the arrival of buses, so that they may join their families. Virtually all studies of evacuations have concluded that this "bonding" process of uniting families is universally prevalent during emergencies and should be anticipated in the planning process. The current public information disseminated to residents of the LGS EPZ indicates that public schoolchildren will be evacuated to host schools, and that parents should pick schoolchildren up at the host schools. The public information indicates non-public (private) schools and day-care centers have their own emergency plans and parents should become familiar with these plans.
As discussed in Section 2, this study assumes a fast breaking general emergency. Therefore, children are evacuated to host schools. Picking up children at school could add to traffic congestion at the schools, delaying the departure of the buses evacuating schoolchildren, which may have to return in a subsequent "wave" to the EPZ to evacuate the transit-dependent population. This report provides estimates of buses under the assumption that no children will be picked up by their parents (in accordance with NUREG/CR-7002), to present an upper bound estimate of buses required. This study assumes that private schools, preschools and day-care centers are also evacuated to host schools and parents will pick up these children at the host schools.
Limerick Generating Station 8-1 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 0
The procedure for computing transit-dependent ETE is to:
Estimate demand for transit service Estimate time to perform all transit functions Estimate route travel times to the EPZ boundary and to the host schools and reception centers 8.1 Transit Dependent People Demand Estimate The telephone survey (see Appendix F) results were used to estimate the portion of the population requiring transit service based on the percentage of households with no vehicle available.
Table 8-1 presents estimates of transit-dependent people. Note:
Estimates of persons requiring transit vehicles include schoolchildren.
For those evacuation scenarios where children are at school when an evacuation is ordered, separate transportation is provided for the schoolchildren. The actual need for transit vehicles by residents is thereby less than the given estimates. However, estimates of transit vehicles are not reduced when schools are in session.
It is reasonable and appropriate to consider that many transit-dependent persons will evacuate by ride-sharing with neighbors, friends or family. For example, nearly 80 percent of those who evacuated from Mississauga, Ontario who did not use their own cars, shared a ride with neighbors or friends. Other documents report that approximately 70 percent of transit dependent persons were evacuated via ride sharing. We will adopt a conservative estimate that 50 percent of transit dependent persons will ride share, in accordance with NUREG/CR-7002.
The estimated number of bus trips needed to service transit-dependent persons is based on an estimate of average bus occupancy of 30 persons at the conclusion of the bus run. Transit vehicle seating capacities typically equal or exceed 60 children on average (roughly equivalent to 40 adults). If transit vehicle evacuees are two thirds adults and one third children, then the number of "adult seats" taken by 30 persons is 20 + (2/3 xl0) = 27. On this basis, the average load factor anticipated is (27/40) x 100 = 68 percent. Thus, if the actual demand for service exceeds the estimates of Table 8-1 by 50 percent, the demand for service can still be accommodated by the available bus seating capacity.
[20+(xo10)]-40x1.5= 1.00 Table 8-1 indicates that transportation must be provided for 3,533 people. Therefore, a total of 118 bus runs are required to transport this population to reception centers.
Limerick Generating Station 8-2 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 0
To illustrate this estimation procedure, we calculate the number of persons, P, requiring public transit or ride-share, and the number of buses, B, required for the LGS EPZ:
P = (EPZ Population - Average HH Size of EPZ) x % of HH with 0 Vehicles x Average HH Size of HH with 0 Vehicles P = (292,136 + 2.54) x 4.8% x 1.28 = 7,066 B = (0.5 x P) + 30 = 118 According to the telephone survey results, there are 1.28 people per house - on average - in households with no vehicles available.
The estimate of transit-dependent population in Table 8-1 far exceeds the number of registered transit-dependent persons in the EPZ as provided by Exelon (discussed below in Section 8.5).
This is consistent with the findings of NUREG/CR-6953, Volume 2, in that a large majority of the transit-dependent population within the EPZs of U.S. nuclear plants does not register with their local emergency response agency.
8.2 School Population - Transit Demand Table 8-2 presents the school, pre-school and daycare population and transportation requirements for the direct evacuation of all facilities within the EPZ for the 2012 school year..
The column in Table 8-2 entitled "Buses Required" specifies the number of buses required for each school under the following set of assumptions and estimates:
No students will be picked up by their parents prior to the arrival of the buses.
While many high school students commute to school using private automobiles (as discussed in Section 2.4 of NUREG/CR-7002), the estimate of buses required for school evacuation do not consider the use of these private vehicles.
Bus capacity, expressed in students per bus, is set to 70 for primary schools and 50 for middle and high schools.
Those staff members who do not accompany the students will evacuate in their private vehicles.
No allowance is made for student absenteeism, typically 3 percent daily.
It is recommended that the counties in the EPZ introduce procedures whereby the schools are contacted prior to the dispatch of buses from the depot, to ascertain the current estimate of students to be evacuated.
In this way, the number of buses dispatched to the schools will reflect the actual number needed. The need for buses would be reduced by any high school students who have evacuated using private automobiles (if permitted by school authorities).
Those buses originally allocated to evacuate schoolchildren that are not needed due to children being picked up by their parents, can be gainfully assigned to service other facilities or those persons who do not have access to private vehicles or to ride-sharing.
Table 8-3 presents a list of the host schools for each school, pre-school and daycare in the EPZ.
Students will be transported to these schools where they will be subsequently retrieved by their respective families.
Limerick Generating Station 8-3 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 0
8.3 Medical Facility Demand Table 8-4 presents the census of medical facilities in the EPZ. A total of 2,765 people have been identified as living in, or being treated in, these facilities. The current census for each facility was provided by Exelon. This data includes the number of ambulatory, wheelchair-bound and bedridden patients at each facility.
The transportation requirements for the medical facility population are also presented in Table 8-4. The number of ambulance runs is determined by assuming that 2 patients can be accommodated per ambulance trip; the number of wheelchair van runs assumes 4 wheelchairs per trip and the number of bus runs estimated assumes 30 ambulatory patients per trip.
8.4 Evacuation Time Estimates for Transit Dependent People EPZ bus resources are assigned to evacuating schoolchildren (if school is in session at the time of the ATE) as the first priority in the event of an emergency. In the event that the allocation of buses dispatched from the depots to the various facilities and to the bus routes is somewhat "inefficient", or if there is a shortfall of available drivers, then there may be a need for some buses to return to the EPZ from the reception center after completing their first evacuation trip, to complete a "second wave" of providing transport service to evacuees. For this reason, the ETE for the transit-dependent population will be calculated for both a one wave transit evacuation and for two waves. Of course, if the impacted Evacuation Region is other than R03 (the entire EPZ), then there will likely be ample transit resources relative to demand in the impacted Region and this discussion of a second wave would likely not apply.
When school evacuation needs are satisfied, subsequent assignments of buses to service the transit-dependent should be sensitive to their mobilization time. Clearly, the buses should be dispatched after people have completed their mobilization activities and are in a position to board the buses when they arrive at the pick-up points.
Evacuation Time Estimates for transit trips were developed using both good weather and adverse weather conditions. Figure 8-1 presents the chronology of events relevant to transit operations. The elapsed time for each activity will now be discussed with reference to Figure 8-1.
Activity: Mobilize Drivers (A--3B-C)
Mobilization is the elapsed time from the Advisory to Evacuate until the time the buses arrive at the facility to be evacuated. It is assumed that for a rapidly escalating radiological emergency with no observable indication before the fact, school bus drivers would likely require 90 minutes to be contacted, to travel to the depot, be briefed, and to travel to the transit-dependent facilities. Mobilization time is slightly longer in adverse weather - 100 minutes when raining, 110 minutes when snowing.
Activity: Board Passengers (C-4D)
A loading time of 15 minutes (20 minutes for rain and 25 minutes for snow) for school buses is assumed.
Limerick Generating Station 8-4 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 0
For multiple stops along a pick-up route (transit-dependent bus routes) estimation of travel time must allow for the delay associated with stopping and starting at each pick-up point. The time, t, required for a bus to decelerate at a rate, "a", expressed in ft/sec/sec, from a speed, "v", expressed in ft/sec, to a stop, is t = v/a. Assuming the same acceleration rate and final speed following the stop yields a total time, T, to service boarding passengers:
2v T=t+B+t=B+2t=B+-
a Where B = Dwell time to service passengers. The total distance, "s" in feet, travelled during the deceleration and acceleration activities is: s = v2/a. If the bus had not stopped to service passengers, but had continued to travel at speed, v, then its travel time over the distance, s, would be: s/v = v/a. Then the total delay (i.e. pickup time, P) to service passengers is:
a a
Assigning reasonable estimates:
B = 50 seconds: a generous value for a single passenger, carrying personal items, to board per stop S
v = 25 mph = 37 ft/sec a = 4 ft/sec/sec, a moderate average rate Then, P = 1 minute per stop. Allowing 30 minutes pick-up time per bus run implies 30 stops per run, for good weather. It is assumed that bus acceleration and speed will be less in rain; total loading time is 40 minutes per bus in rain, 50 minutes in snow.
Activity: Travel to EPZ Boundary (D--'E)
School Evacuation Transportation resources available were provided by Exelon and are summarized in Table 8-5.
Also included in the table are the number of buses needed to evacuate schools, medical facilities, transit-dependent population, homebound special needs (discussed below in Section 8.5) and correctional facilities (discussed below in Section 8.6). These numbers indicate there are sufficient resources available to evacuate all transit-dependent people in a single wave, except for wheelchair vans servicing the homebound special needs population.
The buses servicing the schools are ready to begin their evacuation trips at 105 minutes after the advisory to evacuate - 90 minutes mobilization time plus 15 minutes loading time - in good weather. The UNITES software discussed in Section 1.3 was used to define bus routes along the most likely path from a school being evacuated to the EPZ boundary, traveling toward the appropriate host school. This is done in UNITES by interactively selecting the series of nodes from the school to the EPZ boundary. Each bus route is given an identification number and is written to the DYNEV II input stream. DYNEV computes the route length and outputs the average speed for each 5 minute interval, for each bus route. The specified bus routes are documented in Table 8-6 (refer to the maps of the link-node analysis network in Appendix K for node locations). Data provided by DYNEV during the appropriate timeframe depending on the mobilization and loading times (i.e., 100 to 105 minutes after the advisory to evacuate for good Limerick Generating Station 8-5 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 0
weather) were used to compute the average speed for each route, as follows:
Average Speed (M-)
Z71 length of link i (mi) 60 min.
In Delay on link i (min.) +
length of link i (mi.)
60 min.
X hr.
- =1mi.
1 hr.
current speed on link i ( r.)
h The average speed computed (using this methodology) for the buses servicing each of the schools in the EPZ is shown in Table 8-7 through Table 8-9 for school evacuation, and in Table 8-11 through Table 8-13 for the transit vehicles evacuating transit-dependent persons, which are discussed later. The travel time to the EPZ boundary was computed for each bus using the computed average speed and the distance to the EPZ boundary along the most likely route out of the EPZ. The travel time from the EPZ boundary to the Reception Center or Host School was computed assuming an average speed of 55 mph, 50 mph, and 45 mph for good weather, rain and snow, respectively. Speeds were reduced in Table 8-7 through Table 8-9 and in Table 8-11 through Table 8-13 to 55 mph (50 mph for rain and 45 mph for snow) for those calculated bus speeds which exceed 55 mph, as the school bus speed limit for state routes in Pennsylvania is 55 mph.
Table 8-7 (good weather), Table 8-8 (rain) and Table 8-9 (snow) present the following evacuation time estimates (rounded up to the nearest 5 minutes) for schools in the EPZ: (1) The elapsed time from the Advisory to Evacuate until the bus exits the EPZ; and (2) The elapsed time until the bus reaches the Host School. The evacuation time out of the EPZ can be computed as the sum of times associated with Activities A-OB-OC, C-'D, and D-'E (For example: 90 min. + 15 + 149 = 4:15 for Amity Elementary Center, in good weather, rounded up to the nearest 5 minutes). The evacuation time to the Host School is determined by adding the time associated with Activity E-)F (discussed below), to this EPZ evacuation time.
Evacuation of Transit-Dependent Population The buses dispatched from the depots to service the transit-dependent evacuees will be scheduled so that they arrive at their respective routes after their passengers have completed their mobilization. As shown in Figure 5-4 (Residents with no Commuters), almost all (97%)
evacuees will complete their mobilization when the buses will begin their routes, approximately 90 minutes after the Advisory to Evacuate.
Those buses servicing the transit-dependent evacuees will first travel along their pick-up routes, then proceed out of the EPZ. Transit-dependent pick-up locations are provided annually to EPZ residents in the emergency preparedness brochure. The county emergency plans do not define bus routes to service these pick-up locations. The 13 bus routes shown graphically in Figure 8-2 through Figure 8-4 and described in Table 8-10 were designed as part of this study to service Limerick Generating Station 8-6 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 0
the major routes through each Sub-area and to service the pre-defined pick-up locations. It is assumed that residents will walk to and congregate at these pre-designated pick-up locations, and that they can arrive at the stops within the 90 minute bus mobilization time (good weather).
Pottstown and Phoenixville have high transit-dependent populations and require more buses than any other Sub-area (Table 8-10). As such, two waves of bus service were assigned to the routes within these Sub-areas. The start of service on these routes is separated by 20 minute headways, as shown in Table 8-11 through Table 8-13. The use of bus headways ensures that those people who take longer to mobilize will be picked up. Mobilization time is 10 minutes longer in rain and 20 minutes longer in snow to account for slower travel speeds and reduced roadway capacity.
As previously discussed, a pickup time of 30 minutes (good weather) is estimated for 30 individual stops to pick up passengers, with an average of one minute of delay associated with each stop. Longer pickup times of 40 minutes and 50 minutes are used for rain and snow, respectively.
The travel distance along the respective pick-up routes within the EPZ is estimated using the UNITES software.
Bus travel times within the EPZ are computed using average speeds computed by DYNEV, using the aforementioned methodology that was used for school evacuation.
Table 8-11 through Table 8-13 present the transit-dependent population evacuation time estimates for each bus route calculated using the above procedures for good weather, rain and snow, respectively.
For example, the ETE for the bus route servicing Schedule 1 in Berks County is computed as 90 +
85 + 30 = 3:25 for good weather. Here, 85 minutes is the time to travel 3.6 miles at 2.5 mph, the average speed output by the model for this route starting at 90 minutes. The ETE for a second wave (discussed below) is presented in the event there is a shortfall of available buses or bus drivers, as previously discussed.
Activity: Travel to Reception Centers (E->F)
The distances from the EPZ boundary to the reception centers are measured using GIS software along the most likely route from the EPZ exit point to the reception center. The reception centers are mapped in Figure 10-1 through Figure 10-4. For a one-wave evacuation, this travel time outside the EPZ does not contribute to the ETE. For a two-wave evacuation, the ETE for buses must be considered separately, since it could exceed the ETE for the general population.
Assumed bus speeds of 55 mph, 50 mph, and 45 mph for good weather, rain, and snow, respectively, will be applied for this activity for buses servicing the transit-dependent population.
Activity: Passengers Leave Bus (F->G)
A bus can empty within 5 minutes. The driver takes a 10 minute break.
Limerick Generating Station 8-7 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 0
Activity: Bus Returns to Route for Second Wave Evacuation (G->C)
The buses assigned to return to the EPZ to perform a "second wave" evacuation of transit-dependent evacuees will be those that have already evacuated transit-dependent people who mobilized more quickly. The first wave of transit-dependent people depart the bus, and the bus then returns to the EPZ, travels to its route and proceeds to pick up more transit-dependent evacuees along the route. The travel time back to the EPZ is equal to the travel time to the reception center.
The second-wave ETE for the bus route servicing Schedule 1 in Berks County is computed as follows for good weather:
Bus arrives at reception center at 3:33 in good weather (3:25 to exit EPZ + 8 minute travel time to reception center).
Bus discharges passengers (5 minutes) and driver takes a 10-minute rest: 15 minutes.
Bus returns to EPZ and completes second route: 8 minutes (equal to travel time to reception center) + 65 minutes (3.6 miles @ 3.3 mph) + 4 minutes (3.6 miles @ 55 mph)= 77 minutes Bus completes pick-ups along route: 30 minutes.
Bus exits EPZ at time 3:25 + 0:08 + 0:15 + 1:17 + 0:30 = 5:35 (rounded to nearest 5 minutes) after the Advisory to Evacuate.
The ETE for the completion of the second wave for all transit-dependent bus routes are provided in Table 8-11 through Table 8-13. The average ETE for a one-wave evacuation of transit-dependent people is comparable to the ETE for the general population at the 9 0 th percentile. The two-wave evacuation of transit-dependent people is 1 to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> longer than the ETE for the general population at the 90th percentile.
The relocation of transit-dependent evacuees from the reception centers to congregate care centers, if PEMA and the counties decide to do so, is not considered in this study.
Evacuation of Medical Facilities The evacuation of these facilities is similar to school evacuation except:
Buses are assigned on the basis of 30 patients to allow for staff to accompany the patients. Wheelchair vans can accommodate 4 patients, and ambulances can accommodate 2 patients.
Loading times of 1 minute, 5 minutes, and 15 minutes per patient are assumed for ambulatory
- patients, wheelchair bound patients, and bedridden
- patients, respectively.
Table 8-4 indicates that 78 bus runs, 149 wheelchair van runs and 77 ambulance runs are needed to service all of the medical facilities in the EPZ. According to Table 8-5, the counties can collectively provide 1,910 buses, 663 vans, 162 wheel-chair accessible buses/vans, and 225 ambulances. Thus, there are sufficient resources to evacuate the ambulatory and wheelchair bound persons from the medical facilities in a single wave.
Limerick Generating Station 8-8 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 0
As is done for the schools, it is estimated that mobilization time averages 90 minutes (100 in rain and 110 in snow). Specially trained medical support staff (working their regular shift) will be on site to assist in the evacuation of patients. Additional staff (if needed) could be mobilized over this same 90 minute timeframe.
Table 8-14 and Table 8-16 summarize the ETE for medical facilities within the EPZ for good weather, rain, and snow. Average speeds output by the model for Scenario 6 (Scenario 7 for rain and Scenario 8 for snow) Region 3, capped at 55 mph (50 mph for rain and 45 mph for snow), are used to compute travel time to EPZ boundary. The travel time to the EPZ boundary is computed by dividing the distance to the EPZ boundary by the average travel speed. The ETE is the sum of the mobilization time, total passenger loading time, and travel time out of the EPZ. Concurrent loading on multiple buses, wheelchair vans, and ambulances at capacity is assumed such that the maximum loading times for buses, wheelchair vans and ambulances are 30, 20 and 30 minutes, respectively.
All ETE are rounded to the nearest 5 minutes.
For example, the calculation of ETE for the Chestnut Knoll with 90 ambulatory residents during good weather is:
ETE: 90 + 30 x 1 + 64 = 184 min. or 3:05 rounded to the nearest 5 minutes.
It is assumed that medical facility population is directly evacuated to appropriate host medical facilities outside of the EPZ. Relocation of this population to permanent facilities and/or passing through the reception center before arriving at the host facility are not considered in this analysis.
8.5 Special Needs Population The special needs population were estimated from the transit-dependent population and data provided by Exelon. There are an estimated 264 homebound special needs people within the EPZ who require transportation assistance to evacuate. Approximately 242 transit dependent people would require a wheelchair capable vehicle and 22 would require an ambulance.
ETE for Homebound Special Needs Persons Table 8-17 summarizes the ETE for homebound special needs people. The table is categorized by type of vehicle required and then broken down by weather condition. The table takes into consideration the deployment of multiple vehicles to reduce the number of stops per vehicle.
It is conservatively assumed that ambulatory and wheelchair bound special needs households are spaced 3 miles apart and bedridden households are spaced 5 miles apart. Van and bus speeds approximate 20 mph between households and ambulance speeds approximate 30 mph in good weather (10% slower in rain, 20% slower in snow). Mobilization times of 90 minutes were used (100 minutes for rain, and 110 minutes for snow). The last HH is assumed to be 5 miles from the EPZ boundary, and the network-wide average speed, capped at 55 mph (50 mph for rain and 45 mph for snow), after the last pickup is used to compute travel time. ETE is computed by summing mobilization time, loading time at first household, travel to subsequent households, loading time at subsequent households, and travel time to EPZ boundary. All ETE are rounded to the nearest 5 minutes.
Limerick Generating Station 8-9 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 0
For example, assuming no more than one special needs person per HH implies that 242 wheelchair bound households need to be serviced.
Given a wheelchair van capacity of 4 people, 61 wheelchair vans are needed to service the population. The following outlines the ETE calculations:
- 1. Assume 61 wheelchair vans are deployed, each with about 4 stops, to service a total of 242 HH.
- 2. The ETE is calculated as follows:
- a.
Van arrive at the first pickup location: 90 minutes
- b. Load HH members at first pickup: 5 minutes
- c.
Travel to subsequent pickup locations: 3 @ 9 minutes = 27 minutes
- d. Load HH members at subsequent pickup locations: 3 @ 5 minutes = 15 minutes
- e. Travel to EPZ boundary: 24 minutes (5 miles @ 12.6 mph).
ETE: 90 + 5 + 27 + 15 + 24 = 2:45 rounded up to the nearest 5 minutes Table 8-5 indicates that there are not sufficient wheelchair vans available in the EPZ to evacuate the medical facilities and the homebound special needs population simultaneously. In the event there is a shortfall of wheelchair vans, those vans which evacuate the medical facilities could return to the EPZ to evacuate the homebound special needs population. The estimated additional time for this second wave would be the average ETE for medical facilities, 2:30 (see Table 8-14) plus an estimated 30 minutes to a host facility and 30 minutes back to the EPZ.
Thus, these vehicles would be available in 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> and 30 minutes versus the normal 90 minute mobilization. Thus, a second wave evacuation would require an additional 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> (3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> and 30 minutes minus 90 minutes).
The average ETE for homebound special needs is comparable to the general population ETE at the 9 0 th percentile for a single wave, but would exceed it for a second wave evacuation.
8.6 Correctional Facilities As detailed in Table E-7, there are two correctional facilities within the EPZ - Montgomery County Correctional Facility and the State Correctional Institution at Graterford. The total inmate capacity of these facilities is 6,037 persons. According to the Montgomery County emergency plans and discussions with Exelon, the inmates would shelter-in-place if an evacuation were ordered. Thus, ETE are not computed for these facilities.
Limerick Generating Station 8-10 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 0
(Subsequent Wave)
E3 B 13 C 13 D 13 E 10 0
Time A
Advisory to Evacuate B
Bus Dispatched from Depot C
Bus Arrives at Facility/Pick-up Route D
Bus Departs for Reception Center E
Bus Exits Region F
Bus Arrives at Reception Center/Host Facility G
Bus Available for "Second Wave" Evacuation Service A-+B Driver Mobilization B--C Travel to Facility or to Pick-up Route C-*D Passengers Board the Bus D--E Bus Travels Towards Region Boundary E->F Bus Travels Towards Reception Center Outside the EPZ F->G Passengers Leave Bus; Driver Takes a Break Figure 8-1. Chronology of Transit Evacuation Operations Limerick Generating Station 8-11 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 0
Figure 8-2. Berks County Transit-Dependent Bus Routes Limerick Generating Station Evacuation Time Estimate 8-12 KLD Engineering, P.C.
Rev. 0
Figure 8-3. Chester County Transit-Dependent Bus Routes Limerick Generating Station Evacuation Time Estimate 8-13 KLD Engineering, P.C.
Rev. 0
Figure 8-4. Montgomery County Transit-Dependent Bus Routes Limerick Generating Station Evacuation Time Estimate 8-14 KLD Engineering, P.C.
Rev. 0
Table 8-1. Transit-Dependent Population Estimates 292,136 2.54 115,014 4.8%
5,521 1.28 7,066 50%
3,533 1.2%
Limerick Generating Station Evacuation Time Estimate 8-15 KLD Engineering, P.C.
Rev. 0
Table 8-2. School Population Demand Estimates inIIEDHEJIUIISSI¶[.IiI.
api~iuipiu Busesigi~
Sub-area School N~am Enolmn eqie Amity Amity Elementary Center 793 12 Amity Daniel Boone Middle School 955 20 Amity Monocacy Elementary Center 671 10 Boyertown Boyertown Area High School 1,705 35 Colebrookdale Boyertown Area Junior High School West 791 16 Colebrookdale Boyertown Elementary School 692 10 Colebrookdale Colebrookdale Elementary School 294 5
Douglass Jessie R. Wagner Adventist Elementary School 24 1
Douglass Pine Forge Elementary School 275 4
Washington Brookeside Montessori 50 1
Charlestown Charlestown Elementary School 313 5
East Coventry Collegeville Montessori Academy 39 1
East Coventry East Coventry Elementary School 578 9
East Pikeland East Pikeland Elementary School 327 5
East Pikeland St. Basil the Great School 198 4
East Vincent East Vincent Elementary School 536 8
East Vincent Kimberton-Waldlorf School 301 7
East Vincent Spring City Elementary School 158 3
North Coventry North Coventry Elementary School 613 9
North Coventry West-Mont Christian Academy 315 7
Phoenixville Barkley Elementary School 356 6
Phoenixville Holy Family School 352 8
Phoenixville Kindergarten Center 295 5
Center for Arts and Technology-Pickering 517 11 Schuylkill Campus Schuylkill Phoenixville Area High School 898 18 Schuylkill Phoenixville Area Middle School 750 15 Schuylkill Renaissance Academy 942 19 Schuylkill Schuylkill Elementary School 693 10 South Coventry French Creek Elementary School 527 8
South Coventry Owen J. Roberts High School 1,485 30 South Coventry Owen J. Roberts Middle School 781 16 Upper Uwchlan Pickering Valley Elementary School 688 10 Limerick Generating Station Evacuation Time Estimate 8-16 KLD Engineering, P.C.
Rev. 0
upper uwcnian Upattinas Open Community School 1
45 1
1 1
West Pikeland Montgomery School 271 4
West Vincent West Vincent Elementary School 506 8
Collegeville Perkiomen Valley South Elementary School 627 9
Collegeville St. Eleanor School 500 10 Douglass Gilbertsville Elementary School 697 10 Douglass Wayside Christian School 50 1
Limerick Blessed Theresa of Calcutta 239 5
Limerick Brooke Elementary School 421 7
Limerick Chapel Christian Academy 235 5
Limerick Evans Elementary School 597 9
Limerick Limerick Elementary School 396 6
Limerick Spring-Ford Senior High School 10-12 Grade 1,522 31 Center Limerick Western Center for Technical Studies 459 10 Lower Frederick St. Mary's School 345 7
Lower Potsr Coventry Christian Schools 420 9
Pottsgrove Lower Lower Pottsgrove Elementary School 655 10 Pottsgrove Lower Loter Pottsgrove High School 1,065 22 Pottsgrove Lower Ringing Rocks Elementary 344 5
Pottsgrove Lower Poven Arcola Intermediate School 842 17 Providence Lower LwrArrowhead Elementary School 326 5
Providence Lower LwrAudubon Elementary 401 6
Providence Lower Prowierc Eagleville Elementary School 338 5
Providence SyiwUprEeetr col751 Poven St. Gabriel's Hall 210 5
Providence Lower Poven Woodland Elementary 291 5
Providence New Hanover Boyertown Area Junior High School East 903 19 Limerick Generating Station Evacuation Time Estimate 8-17 KLD Engineering, P.C.
Rev. 0
S.
SBu se New Hanover New Hanover-Upper Frederick Elementary School 728 11 New Hanover Perkiomen Valley Academy 24 1
Perkiomen Evergreen Elementary School 685 10 Perkiomen Perkiomen Valley High School 1,808 37 Perkiomen Perkiomen Valley Middle School - East 782 16 Pottstown Edgewood Elementary School 288 5
Pottstown Elizabeth B. Barth Elementary School 421 7
Pottstown Franklin Elementary School 301 5
Pottstown Lincoln Elementary School 378 6
Pottstown Pottstown High School 823 17 Pottstown Pottstown Middle School 600 12 Pottstown Rupert Elementary School 270 4
Pottstown St. Aloysius 522 11 Pottstown St. Peter's Lutheran Church - School 182 4
Pottstown The Hill School 496 10 Pottstown Wyndcroft School 233 5
Royersford Royersford Elementary School 431 7
Royersford Sacred Heart School 115 3
Royersford Spring-Ford 8th Grade Center 609 13 Schwenksville Schwenksville Elementary School 541 8
Skippack Skippack Elementary School 782 12 Trappe Bright Spot Kindergarten 130 2
Upper Frederick Perkiomen Valley Middle School -West 605 13 Upper pper Pottsgrove Middle School 762 16 Pottsgrove Upper pr Oaks Elementary School 520 8
Providence Upper Providence Pope John Paul II High School 896 18 Upper Providence Spring-Ford 5th-6th Grade Center 1,258 26 Upper Providence Spring-Ford 7th Grade Center 589 12 Upper Spring-Ford Senior High School 9th Grade 579 12 Providence Center Upper Providence Upper Providence Elementary School 532 8
Upper Valley Forge Baptist Temple Academy 185 4
Providence Limerick Generating Station Evacuation Time Estimate 8-18 KLD Engineering, P.C.
Rev. 0
Upper Salford New Life Youth & Family Services I
53 2
I Upper Salford Salford Hills Elementary 330 5
West Pottsgrove West Pottsgrove Elementary School 461 7i Amity Douglassville Children's Center 73 2
Amity Douglassville KinderCare 129 2
Amity St. Gabriel's Good Shepherd Learning Center 100 2
Amity St. Paul's Day Care 159 3
Amity Teresa Walter Family Daycare 12 1
Boyertown St. John's Lutheran Church 50 1
Colebrookdale Almost Home Children's Center 87 2
Colebrookdale Boyertown Area YMCA 371 6
Colebrookdale Saint Columbkill Preschool 60 1
Union Gail Swartz Family Daycare 12 1
East Coventry East Coventry Elementary School 34 1
East Coventry Our House Early Learning Center 42 1
East Pikeland Kindercare Learning Center No. 1405 137 2
East Pikeland Teach & Learn Day School 64 1
East Vincent Grace Assembly Day Care Center 59 1
North Coventry Warwick Child Care - North Coventry Center 246 4
Phoenixville International Montessori 56 1
Phoenixville Little Angels Day Care 70 1
Phoenixville Phoenixville Area Children's Learning Center 78 2
Phoenixville Phoenixville Area Children's Learning Center 2 91 2
Phoenixville Stepping Stone Education Center 50 1
Phoenixville Valley Forge Kinder House Montessori School 43 1
Schuylkill Kiddie Academy 135 2
Schuylkill Magic Memories 65 1
Schuylkill Phoenixville Area YMCA Child Care Center 237 4
South Coventry Pottstown YMCA French Creek Elementary 22 1
South Coventry Warwick Child Care - South Coventry Center 89 2
Spring City Kids Kare Korner 29 1
Upper Uwchlan Bright Light Early Learning Center 119 2
Upper Uwchlan The Goddard School - Chester Springs 116 2
8-19 KLD Engineering, P.C.
Limerick Generating Station Evacuation Time Estimate 8-19 KLD Engineering, P.C.
Rev. 0
1AInnAltrie
~RI2 r~flrle
( hil~ron'c Wniien nt Nl~nrthnrn I haetar UiintuI I
-.--I LI Collegeville Bright Spot Child Care 130 2
Collegeville Creative Child Care Too 77 2
Collegeville Tot Spot Learning Center 69 1
Douglass Boyertown Children's Center 76 2
Douglass Little Faces Learning Center 49 1
Douglass The Goddard School - Gilbertsville 112 2
Douglass YMCA Growing Dreams Child Care Center 283 5
Limerick Bright Beginnings Child Care Center 209 3
Limerick Chesterbrook Academy - Limerick 137 2
Limerick Chesterbrook Academy - Royersford 366 6
Limerick Country Tyme Day Care 225 4
Limerick FV YMCA - Brooke Elementary School 458 7
Limerick FV YMCA - Evans Elementary School 184 3
Limerick FV YMCA - Limerick Elementary School 125 2
Limerick FV YMCA - Spring Valley 29 1
Limerick Kiddie Academy Royersford 175 3
Limerick Kinder Works 190 3
Limerick The Malvern School - Royersford 141 3
Lowe r Powgr Coventry Christian Pre-School 150 3
Pottsgrove Lower Lotgr Kindercare 3056 160 3
Pottsgrove Lower Lotgr The Goddard School - Sanatoga 119 2
Pottsgrove Lower Potgr The Learning Experience 158 3
Pottsgrove Lower Potsr Wee Care Child Development Center 81 2
Pottsgrove Lower Poven Chesterbrook Academy - Collegeville 169 3
Providence Lower Poven Chesterbrook Academy - Norristown 150 3
Providence Lower Poven Creative Beginnings Preschool 40 1
Providence Lower Poven FV YMCA - Audubon Elementary 65 1
Providence Lower Poven FV YMCA - Woodland Elementary 127 2
Providence 8-20 KLD Engineering, P.C.
Limerick Generating Station Evacuation Time Estimate 8-20 KLD Engineering, P.C.
Rev. 0
Lower roven Phoenixville Area YMCA - Eagleville Elementary 158 3
Providence Lower roven Phoenixville Area YMCA-Arrowhead Elementary 110 2
Providence Lower Providence Play and Learn - Collegeville 102 2
Lower Poven Short Stuff & Co 132 2
Providence Lower Providence Valley Forge Children's Academy 96 2
Lower Providence Victory Early Learning Academy 97 2
Marlborough Play and Learn - Green Lane 189 3
New Hanover Hendricks Family Growing Dreams 278 4
New Hanover New Hanover Child Care 58 1
Perkiomen Flanagan's Pre-School 150 3
Perkiomen FV YMCA - Perkiomen Valley Middle School 144 3
Perkiomen Kiddie Academy Collegeville 186 3
Perkiomen The Goddard School - Schwenksville 115 2
Pottstown Dotlen Academy 145 3
Pottstown FV YMCA - Pottstown Day Care 229 4
Pottstown Little Mary Daycare 58 1
Pottstown Montgomery Early Learning Center 24 1
Pottstown Sunny Dayz Child Care 50 1
Pottstown YWCA Hill School Preschool 11 1
Pottstown YWCA Ready Set Grow 97 2
Pottstown YWCA Tricounty Daycare 12 1
Royersford FV YMCA - Royersford Elementary School 123 2
Royersford Kids Kare Korner III 144 3
Royersford Spring Valley YMCA Child Care Facility 81 2
Royersford The Goddard School - Royersford 160 3
Schwenksville Jerusalem Lutheran Day Care Center 43 1
Schwenksville North Penn YMCA - Schwenksville Elementary 234 4
Skippack The Goddard School - Skippack 117 2
Skippack Tykes and Tots Day Care 86 2
Trappe Twin Acres Country Day School 68 1
Upper Creative Minds Montessori 104 2
Pottsgrove Upper pr Chesterbrook Academy - Phoenixville 150 3
Providence 8-21 KLD Engineering, P.C.
Limerick Generating Station Evacuation Time Estimate 8-21 KLD Engineering, P.C.
Rev. 0
@6 B
Buses Upper Providence Children of America Trappe 156 3
Upper Kindercare 3060 135 2
Providence Upper Oaks Early Learning 74 2
Providence Upper Phoenixville Area YMCA-Oaks Elementary 79 2
Providence School Upper Play and Learn - Royersford 67 1
Providence Upper Providence Christian Preschool 61 1
Providence Upper pr SEI Family Center 193 3
Providence Upper The Malvern School - Collegeville 136 2
Providence Upper The Malvern School of Oaks 136 2
Providence Upper Salford North Penn YMCA - Salford Hills Elementary 107 2
Wprt Pnttrornvp I ittlp Inntnrint-Q1 7
Note: Student population for Ursinus College (1,750 students) and Valley Forge Christian College (800 students) are included in the permanent resident population.
8-22 KLD Engineering, P.C.
Limerick Generating Station Evacuation Time Estimate 8-22 KLD Engineering, P.C.
Rev. 0
Table 8-3. School Reception Centers Jessie R. Wagner Adventist Elementary School Blue Mountain Academy Barkley Elementary School Conestoga High School Amity Elementary Center Daniel Boone Middle School Daniel Boone High School Monocacy Elementary Center Boyertown Area High School Boyertown AreaJ High School Keystone Hall - Kutztown University Boyertown Area Junior High School West Boyertown Elementary School Kutztown Area Middle School Brookeside Montessori Brooesie MotesoriKutztown Elementary School Pine Forge Elementary School Colebrookdale Elementary School Kuztown Area High School Center for Arts and Technology-Pickering Campus East Pikeland Elementary School Kindergarten Center Phoenixville Area High School Conestoga High School Phoenixville Area Middle School Schuylkill Elementary School Montgomery School intgemenary School Downington High School West Pickering Valley Elementary School Charlestown Elementary School Great Valley High School Collegeville Montessori Academy Gwynedd Square Elementary Holy Family School St. Basil the Great School Immaculata University West-Mont Christian Academy King's Highway Elementary School Spring City Elementary School Plymouth-Whitemarsh High School Renaissance Academy Stetson Middle School Valley Forge Christian College East Coventry Elementary School East Vincent Elementary School French Creek Elementary School Twin Valley Elementary School North Coventry Elementary School West Vincent Elementary School Owen J. Roberts High School Twin Valley Middle / High School Owen J. Roberts Middle School Kimberton-Waldorf School West Chester University 8-23 KLD Engineering, P.C.
Limerick Generating Station Evacuation Time Estimate 8-23 KLD Engineering, P.C.
Rev. 0
Scol Hos Scho Upattinas Open Community School Wayside Christian School Administrator's Home Chapel Christian Academy Calvery Baptist - Lansdale New Life Youth & Family Services Carson Valley School (Erdenheim)
The Hill School Catasuqua High School St. Mary's School Corpus Christi School Coventry Christian Schools Daniel Boone High School Pope John Paul II High School DeSales University Edgewood Elementary School Elizabeth B. Barth Elementary School Franklin Elementary School Lincoln Elementary School Emmaus High School Pottstown High School Pottstown Middle School Rupert Elementary School Bright Spot Kindergarten Gwynedd Square Elementary Salford Hills Elementary Indian Valley Middle School Ursinus College Jenkintown Middle and High School Boyertown Area Junior High School East Keystone Hall - Kutztown University Gilbertsville Elementary School Kutztown Elementary School New Hanover-Upper Frederick Elementary School Kuztown Area High School Blessed Theresa of Calcutta Western Center for Technical Studies Mongomery County Community College St. Eleanor School Mother of Divine Providence School Arrowhead Elementary School Audubon Elementary Eagleville Elementary School Norristown Area High School Skyview Upper Elementary School Woodland Elementary Evergreen Elementary School Perkiomen Valley High School Perkiomen Valley Middle School - East Perkiomen Valley Middle School -West North Penn High School Perkiomen Valley South Elementary School Schwenksville Elementary School Skippack Elementary School Valley Forge Baptist Temple Academy Penn Christian Academy Brooke Elementary School Plymouth-Whitemarsh High School Limerick Generating Station Evacuation Time Estimate 8-24 KLD Engineering, P.C.
Rev. 0
I Schol Hos Scoo I
Evans Elementary School Limerick Elementary School Oaks Elementary School Royersford Elementary School Spring-Ford 5th-6th Grade Center Spring-Ford 7th Grade Center Spring-Ford 8th Grade Center Spring-Ford Senior High School 10-12 Grade Center Spring-Ford Senior High School 9th Grade Center Upper Providence Elementary School Sacred Heart School Saint Philip Neri School Lower Pottsgrove Elementary School Pottsgrove High School Pottsgrove Middle School Southern Lehigh High School Ringing Rocks Elementary West Pottsgrove Elementary School St. Peter's Lutheran Church - School St. Ann School St. Aloysius St. Thomas More School Perkiomen Valley Academy The Lakeside School - Prospectville Wyndcroft School The Swain School Arcola Intermediate School St. Gabriel's Hall West Philadelphia Catholic High School Almost Home Children's Center Emmaus High School Douglassville KinderCare St. Gabriel's Good Shepherd Learning Center Exeter Township Building St. Paul's Day Care Boyertown Area YMCA Douglassville Children's Center Saint Columbkill Preschool Oley Valley High School St. John's Lutheran Church Teresa Walter Family Daycare Gail Swartz Family Daycare Robeson Township Building Bright Light Early Learning Center The Goddard School - Chester Springs Children's House of Northern Chester County Honeybrook Early Learning Center 8-25 KLD Engineering, P.C.
Limerick Generating Station Evacuation Time Estimate 8-25 KLD Engineering, P.C.
Rev. 0
Schol Ho Schoo I
Pottstown YMCA French Creek Elementary Warwick Child Care - South Coventry Center Morgantown Crossings Our House Early Learning Center Robeson Township Building Warwick Child Care - North Coventry Center International Montessori Kiddie Academy Little Angels Day Care Magic Memories Phoenixville Area Children Learning Center Stetson Middle School Phoenixville Area Children's Learning Center 2 Phoenixville Area YMCA Child Care Center Stepping Stone Education Center Valley Forge Kinder House Montessori School East Coventry Elementary School Twin Valley Elementary School Grace Assembly Day Care Center Kids Kare Korner West Whiteland Township Building Kindercare Learning Center No. 1405 Teach & Learn Day School Bright Spot Child Care Brigt Spt Cild areGwynedd Square Elementary Twin Acres Country Day School North Penn YMCA - Salford Hills Elementary Indian Valley Middle School Boyertown Children's Center Bright Beginnings Child Care Center Chesterbrook Academy - Collegeville Chesterbrook Academy - Limerick Chesterbrook Academy - Norristown Chesterbrook Academy - Phoenixville Chesterbrook Academy - Royersford Children of America Trappe Montgomery County Community College Coventry Christian Pre-School Creative Beginnings Preschool Creative Child Care Too Creative Minds Montessori Dotlen Academy Flanagan's Pre-School FV YMCA - Pottstown Day Care FV YMCA - Spring Valley Limerick Generating Station Evacuation Time Estimate 8-26 KLD Engineering, P.C.
Rev. 0
Scol Hos School Hendricks Family Growing Dreams Jerusalem Lutheran Day Care Center Kiddie Academy Collegeville Kiddie Academy Royersford Kids Kare Korner III Kinder Works Kindercare 3056 Kindercare 3060 Little Faces Learning Center Little Footprints Little Mary Daycare Montgomery Early Learning Center New Hanover Child Care Oaks Early Learning Play and Learn - Royersford Providence Christian Preschool SEI Family Center Short Stuff & Co Spring Valley YMCA Child Care Facility Montgomery County Community College Sunny Dayz Child Care The Goddard School - Gilbertsville The Goddard School - Royersford The Goddard School - Sanatoga The Goddard School - Schwenksville The Goddard School - Skippack The Learning Experience The Malvern School - Collegeville The Malvern School - Royersford The Malvern School of Oaks Tot Spot Learning Center Tykes and Tots Day Care Valley Forge Children's Academy Victory Early Learning Academy Wee Care Child Dev Center YMCA Growing Dreams Child Care Center YWCA Hill School Preschool YWCA Ready Set Grow YWCA Tricounty Daycare FV YMCA - Audubon Elementary Norristown Area High School FV YMCA - Woodland Elementary 8-27 KLD Engineering, P.C.
Limerick Generating Station Evacuation Time Estimate 8-27 KLD Engineering, P.C.
Rev. 0
I Scoos Hos Scoo I
Phoenixville Area YMCA - Eagleville Elementary Phoenixville Area YMCA-Arrowhead Elementary FV YMCA - Perkiomen Valley Middle School North Penn High School North Penn YMCA - Schwenksville Elementary Country Tyme Day Care Penn Christian Academy Play and Learn - Collegeville Play and Learn - Grlegenlane Play and Learn - Fort Washington Play and Learn - Green Lane FV YMCA - Brooke Elementary School FV YMCA - Evans Elementary School FV YMCA - Limerick Elementary School FV YMCA - Royersford Elementary School Plymouth-Whitemarsh High School Phoenixville Area YMCA-Oaks Elementary School Limerick Generating Station Evacuation Time Estimate 8-28 KLD Engineering, P.C.
Rev. 0
Table 8-4. Medical Facility Transit Demand
.oyertown CLestnut Knoll lUI 9u 1U 8
2 3
1 Union Colonial Manor Adult Home 24 20 4
3 1
1 1
1 Amity Hearthstone at Amity 100 90 10 8
2 3
2 1
Amity Keystone Villa 114 100 14 11 3
4 3
2 East Pikeland Atria Woodbridge Place 120 110 10 8
2 4
2 1
South Coventry Coventry Manor Nursing Home 41 33 8
6 2
2 2
1 East Pikeland Genesis Health Care at Spring Mill 22 20 2
2 0
1 1
0 Phoenixville Golden Living Centers -
130 125 5
4 1
5 1
1 Phoenixville East Coventry Manatawny Manor 120 40 80 64 16 2
16 8
Phoenixville Phoenixville Convalescent Manor 68 18 50 40 10 1
10 5
Phoenixville Phoenixville Hospital of the 127 67 60 48 12 3
12 6
UPENN Health System East Vincent Southeastern Pennsylvania 185 165 20 16 4
6 4
2 Veterans Center Lower Providence Eagleville Hospital 272 222 50 40 10 8
10 5
Upper Frederick Frederick Mennonite Community 126 96 30 24 6
4 6
3 Pottstown HCR ManorCare 206 103 103 82 21 4
21 11 Lower Pottsgrove Park Lane Commons 85 75 10 8
2 3
2 1
Limerick Generating Station Evacuation Time Estimate 8-29 KLD Engineering, P.C.
Rev. 0
S~~~W el chair*
S*
Upper Providence Parkhouse, Providence Pointe 451 400 51 41 10 14 11 6
Pottstown Pottstown Memorial Medical 295 115 180 144 36 4
36 18 Center Lower Pottsgrove Sanatoga Center 119 95 24 19 5
4 5
3 Lower Providence Shannondell at Valley Forge 60 50 10 8
2 2
2 1
MotoerySubtotal. 11,14 1 1,56 1 458 6
92 43 9>3 Limerick Generating Station Evacuation Time Estimate 8-30 KLD Engineering, P.C.
Rev. 0
Table 8-5. Summary of Transportation Resources County~~~~~~
Bue as Bss/as A
blne I Montgomery I
566 I 313 I
46 I
90 I
I Chester 1 1,079 I 150 1
80 I
60 1
I RtarIe I
)A.
7nn I
- U 71; 1
Limerick Generating Station Evacuation Time Estimate 8-31 KLD Engineering, P.C.
Rev. 0
Table 8-6. Bus Route Descriptions Bus 1
Amity Elementary Center 595,696,697,698,699,23,22,21,20 807,808,809,3818,810,811,812,3815,929,928, 925, 922, 923, 924, 918, 920, 919, 894, 3299, 895, 2
Coventry Christian Schools 896, 897, 898, 899, 3829, 3304, 1223, 1192, 1193, 1194, 1195, 1196, 1197, 1198, 1199, 1200, 1201, 1202,1203,3293 3
Arcola Intermediate School 3080,3081,3082,771,772,773,774,775 4
rrowhead Elementary School 3072, 3071, 769, 4514, 4515, 770, 4160, 771, 772, 773, 774, 775 5
Audubon Elementary School 4157, 3376, 4454, 3083 1237, 1238, 3862, 3863, 4430, 4426, 3395, 3503, 3919,3504,4270,3505,3506,3507,3508,3904 3807, 415, 414, 413, 430, 431, 432, 433, 547, 434, 7
Boyertown Elementary School 3
3 435,436 975, 976, 4165, 4164, 640, 641, 642, 643, 4477, 8
Boyertown Junior High School East 4182, 644, 645, 646, 647, 648, 649, 650, 651, 413, 430,431,432,433,547,434,435,436 3807, 415, 414, 413, 430, 431, 432, 433, 547, 434, 9
Boyertown Area Junior High School West3546 435,436 148, 649, 650, 651, 413, 430, 431, 432, 433, 547, 10 Boyertown Area High School 3
3 3
434,435,436 3326, 1597, 1601, 3325, 1611, 1610, 1609, 3879, 1600, 1608, 1607, 1606, 3886, 3884, 756, 757, 11 Brooke Elementary School 3887, 758, 1721, 759, 760, 761, 4463, 762, 4384, 763, 764, 765, 766, 767, 768, 4392, 1997, 1998, 1999,3000 873,869,4497,3298,850,852,858,457,458,459, 12 Central Zone 460, 461, 462, 463, 464, 465, 3805, 466, 467, 468, 469,470,471,472,473,474,475,476,477 13 Charlestown Elementary School 3899, 3404, 3901 14 Colebrookdale Elementary School 413, 430, 431, 432, 433, 547, 434, 435, 436 15 Daniel Boone Middle School 399, 4438, 4485 8-32 KLD Engineering, P.C.
Limerick Generating Station Evacuation Time Estimate 8-32 KLD Engineering, P.C.
Rev. 0
Bus.
0 16 Downtown Area
- 3348, 1547,
- 3397, 3901
- 3498, 4546,
- 3398, 3857,
- 3862, 3399, 3858, 3860, 4428, 3863, 4430, 4426, 3400, 3401, 3402,
- 3390, 3395,
- 3403, 3861,
- 3396, 3404, 17 Eagleville Elementary School 771, 772, 4462 1224, 3559, 3560, 3561, 3562, 3563, 3564, 1414, 18 East Coventry Elementary School 1413, 3565, 1412, 1292, 1345, 1347, 1346, 1411, 1410, 4413, 1409, 1408, 1407, 1402 3789, 3415, 3414, 3413, 3412, 3510, 3497, 3395, 19 East Pikeland Elementary School 3396, 3397, 3398, 3399, 3400, 3401, 3402, 3403, 3404, 3508, 3904 3389, 3390, 3391, 3355, 1239, 3863, 4430, 4426, 20 East Side 3395, 3396, 3397, 3398, 3399, 3400, 3401, 3402, 3403, 3404, 3901 1414, 1413, 3565, 1412, 1292, 1345, 1347, 1346, 1411, 1410, 4413, 1409, 1408, 1407, 1402 810, 811, 4496, 913, 912, 914, 814, 815, 816, 817, 818, 819, 820, 821, 822, 823, 824, 825, 3298, 850, 22 East Zone 852, 858, 457, 458, 459, 460, 461, 462, 463, 464, 465, 3805, 466, 467, 468, 469, 470, 471, 472, 473, 474, 475, 476, 477 455, 456, 727, 457, 458, 459, 460, 461, 462, 463, 23 Elizabeth B Barton Elementary School 464, 465, 3805, 466, 467, 468, 469, 470, 471, 472, 473, 474, 475, 476, 477 4176, 756, 757, 3887, 758, 1721, 759, 760, 761, 24 Evans Elementary School 463, 762, 4384, 763, 764, 765, 766, 767, 768, 4392, 1997, 1998, 1999, 3000 25 Evergreen Elementary School 1767, 1836, 1835, 1837, 1838, 1839, 1840, 1841, 1842, 1566, 1567, 1568, 1569, 1570, 1571 877, 856, 857, 858, 457, 458, 459, 460, 461, 462, 26 Franklin Elementary School 463, 464, 465, 3805, 466, 467, 468, 469, 470, 471, 472, 473, 474, 475, 476, 477 27 French Creek Elementary School 1347, 1346, 1411, 1410, 4413, 1409, 1408, 1407, 1402 640, 641, 642, 643, 4477, 4182, 644, 645, 646, 647, 28 3ilbertsville Elementary School 648, 649, 650, 651, 413, 430, 431, 432, 433, 547, 434, 435, 436 Limerick Generating Station Evacuation Time Estimate 8-33 KLD Engineering, P.C.
Rev. 0
Bus*
0 29 Kindergarten Center 3392, 3355, 1239, 3863, 4430, 4426, 3395, 3503, 3919,3504,4270,3505,3506,3507,3508,3904 746, 747, 748, 749, 750, 751, 752, 753, 754, 1612, 3882, 755, 756, 757, 3887, 758, 1721, 759, 760, 761,4463,762,4384,763,764,765,766,767,768, 4392,1997,1998,1999,3000 904, 965, 966, 967, 968, 892, 893, 987, 635, 971, 31 Lower Pottsgrove Elementary School 972, 973, 974, 977, 552, 1035, 1036, 1037, 625, 4382 32 Monacacy Elementary School 3294, 3295, 3293 550, 551, 552, 553, 988, 554, 555, 556, 684, 557, 33 New Hanover Elementary School5849,9744,47558, 496, 497, 4448, 477 1284, 1285, 1286, 1287, 1288, 1289, 4434, 1290, 34 North Coventry Elementary School 1291, 1292, 1345, 1347, 1346, 1411, 1410, 4413, 1409,1408,1407,1402 3342, 3343, 3344, 3345, 3346, 3347, 3848, 3348, 35 North Side 3857, 3859, 4427, 3389, 4474, 1238, 3862, 1239, 3863, 4430, 4426, 3395, 3396, 3397, 3398, 3399, 3400,3401,3402,3403,3404,3901 3932, 909, 877, 856, 857, 859, 860, 861, 862, 461, 36 North Zone 462, 463, 464, 465, 3805, 466, 467, 468, 469, 470, 471, 472, 473, 474, 475, 476, 477 37 Oaks Elementary School 3361, 3359, 3360, 74, 75, 76, 77, 78, 79, 80 1292, 1345, 1347, 1346, 1411, 1410, 4413, 1409, 38 Owen J. Roberts High School 10,10,10 1408,1407,1402 39 1wenJ. RobertsMiddle School 1292, 1345, 1347, 1346, 1411, 1410, 4413, 1409, 1408,1407,1402 1765, 1766, 1767, 1836, 1835, 1837, 1838, 1839, 40 Perkiomen Valley High School 1840, 1841, 1842, 1566, 1567, 1568, 1569, 1570, 1571 1767, 1836, 1835, 1837, 1838, 1839, 1840, 1841, 41 Perkiomen Valley Middle School East 14,16,16,16,16,17,17 1842,1566,1567,1568,1569,1570,1571 998, 4161, 4162, 999, 4389, 4390, 1626, 1625, 1624, 1623, 1533, 1532, 1622, 1621, 1555, 1556, 1557, 1558, 1559, 1560, 1561, 1562, 1563, 1564, 1565,1566,1567,1568,1569,1570,1571 Limerick Generating Station Evacuation Time Estimate 8-34 KLD Engineering, P.C.
Rev. 0
Route Noe Trvese frmRut trtt 43 Edgewood Elementary School 912, 911, 910, 909, 877, 856, 857, 858, 457, 458, 459, 460, 461, 462,463, 464, 465, 3805, 466, 467, 468,469,470,471,472,473,474,475,476,477 44 Phoenixville Area Middle School 4426, 3395, 3503, 3919, 3504, 4270, 3505, 3506, 3507, 3508, 3904 45 Pickering Valley Elementary School 3605, 3603, 3604, 3976, 1316, 1317, 1318 724, 725, 726, 700, 712, 4480, 4481, 4482, 398, 46 Pine Forge Elementary School9,40 399, 400 884, 885, 968, 892, 893, 987, 635, 971, 972, 973, 974, 977, 552, 1035, 1036, 1037, 625, 4382 884, 885, 968, 892, 893, 987, 635, 971, 972, 973, 974, 977, 552, 1035, 1036, 1037, 625, 4382 877, 856, 857, 858, 457, 458, 459, 460, 461, 462, 49 Pottstown High School 463, 464, 465, 3805, 466, 467, 468, 469, 470, 471, 472, 473, 474, 475, 476, 477 3825, 874, 875, 876, 877, 856, 857, 858, 457, 458, 50 Pottstown Middle School 459, 460, 461, 462, 463, 464, 465, 3805, 466, 467, 468, 469, 470, 471, 472, 473, 474, 475, 476, 477 852, 858, 457, 458, 459, 460, 461, 462, 463, 464, 51 Lincoln Elementary School 465, 3805, 466, 467, 468, 469, 470, 471, 472, 473, 474, 475, 476, 477 584, 885, 968, 892, 893, 987, 635, 971, 972, 973, 574, 977, 552, 1035, 1036, 1037, 625, 4382 1699, 1698, 1601, 3325, 1611, 1610, 63, 64, 65, 66, 53 Royersford Elementary School 67, 68, 69, 70, 87, 88, 71, 72, 73, 74, 75, 76, 77, 78, 79,80 813, 3820, 814, 815, 816, 817, 818, 819, 820, 821, 522, 823, 824, 825, 3298, 850, 852, 858, 457, 458, 559, 460, 461, 462, 463, 464, 465, 3805, 466, 467, 468, 469, 470, 471, 472, 473, 474, 475, 476, 477 55 Sacred Heart School 1707, 1611, 1610, 63, 64, 65, 66, 67, 68, 69, 70, 87, 58, 71, 72, 73, 74, 75, 76, 77, 78, 79, 80 56 Salford Hills Elementary School 1664, 1789, 1540, 1790 57 chedule 1 15, 414, 413, 430, 431, 432, 433, 547, 434, 435, 136 Limerick Generating Station Evacuation Time Estimate 8-35 KLD Engineering, P.C.
Rev. 0
58 3chedule 2
- 58U/, b4/, b4d, b493, bbU, b51, 413, 43U, 431, 432 433, 547, 434, 435, 436 59 Schedule 3 413, 430, 431, 432, 433, 547, 434, 435, 436 60 Schedule 4 430, 431, 432, 433, 547, 434, 435, 436 61 Schedule 5 649, 650, 651, 413, 430, 431, 432, 433, 547, 434, 435, 436 4431, 3503, 3919, 3504, 4270, 3505, 3506, 3507, 62
- chuylkill Elementary School50,34 3508, 3904 4398, 1555, 1556, 1557, 1558, 1559, 1560, 1561, 63 Schwensville Elementary School 1562, 1563, 1564, 1565, 1566, 1567, 1568, 1569, 1570, 1571 64 Skippack Elementary School 1982, 1983, 1568, 1569, 1570, 1571 65 Skyview Upper Elementary School 3080, 3081, 3082, 771, 772, 773, 774, 775 1771, 4538, 1767, 1836, 1835, 1837, 1838, 1839, 66 South Elementary School 1840, 1841, 1842, 1566, 1567, 1568, 1569, 1570, 1571 819, 820, 821, 822, 823, 824, 825, 3298, 850, 852, 67 South Zone 858, 457, 458, 459, 460, 461, 462, 463, 464, 465, 3805, 466, 467, 468, 469, 470, 471, 472, 473, 474, 475, 476, 477 68 Brookeside Montessori 434, 435, 436 69 Montgomery School 3424, 3425, 3426, 3427, 3428, 3433, 3432, 3429.
3430 1707, 1611, 1610, 63, 64, 65, 66, 67, 68, 69, 70, 87, 88, 71, 72, 73, 74, 75, 76, 77, 78, 79, 80 1607, 1606, 3886, 3884, 756, 4176, 1593, 1777, 1619, 1552, 1553, 1554, 4397, 4398, 1555, 1621, 1622, 1532, 1533, 1623, 1624, 1625, 1626, 4390, 4389, 999, 4163, 1122, 1129, 4166, 1127, 1128, 1188, 1107, 1143, 1153, 1116, 1154, 1155, 562, 4368, 563, 564, 565 1702, 1701, 1700, 1699, 1698, 1601, 3325, 1611, 72 Spring City Elementary School 1610, 63, 64, 65, 66, 67, 68, 69, 70, 87, 88, 71, 72, 73, 74, 75, 76, 77, 78, 79, 80 Limerick Generating Station Evacuation Time Estimate 8-36 KID Engineering, P.C.
8-36 KLD Engineering, P.C.
Rev. 0
Bus 0
0 73 St. Aloysius School 368, 855, 853, 854, 857, 859, 860, 861, 862, 461, 462, 463, 464, 465, 3805, 466, 467, 468, 469, 470, 471, 472, 473, 474, 475, 476, 477 1754, 1737, 3872, 3869, 3877, 1736, 1735, 1734, 74 St. Eleanor Rectory 3041, 3042, 1733, 1732, 3340, 68, 69, 70, 87, 88, 71, 72, 73, 74, 75, 76, 77, 78, 79, 80 75 St. Mary's School 1636, 1637, 1641, 1813, 1536, 1541, 1542 456, 727, 457, 458, 459, 460, 461, 462, 463, 464, 76 St. Peter's School 465, 3805, 466, 467, 468, 469, 470, 471, 472, 473, 474, 475, 476, 477 916, 917, 904, 965, 966, 967, 968, 892, 893, 987, 77 St. Pius X High School 635, 971, 972, 973, 974, 977, 552, 1035, 1036, 1037, 625, 4382 7K463, 762, 4384, 763, 764, 765, 766, 767, 768, 78 Bright Spot Kindergarten39,17,98,99,00 4,392, 1997, 1998, 1999, 3000 1544, 1580, 1593, 1777, 1619, 1785, 1786, 1787, 79 West Montgomery Career and Tech Ctr 1783, 1784, 1559, 1560, 1561, 1562, 1563, 1564, 1565, 1566, 1567, 1568, 1569, 1570, 1571 80 West Pottsgrove Elementary Schoo843 893, 987, 635, 971, 972, 973, 974, 977, 552, 1035, 1036, 1037, 625, 4382 1705, 1703, 1702, 1704, 4435, 1227, 4425, 4424, 1228, 3844, 1229, 1230, 1231, 1232, 3853, 3855, 81 est Side 1233, 1234, 1235, 1236, 1237, 1238, 3862, 1239, 3863, 4430, 4426, 3395, 3396, 3397, 3398, 3399, 3400, 3401, 3402, 3403, 3404, 3901 3566, 1308, 3579, 3580, 3581, 3582, 3583, 3584, 82 West Vincent Elementary SchoolS8,36,S8 S8 1S 3585, 3586, 3587, 3588, 1451 1582, 1613, 1614, 1615, 1616, 1617, 1618, 1527, 1528, 1529, 1530, 1531, 1620, 4399, 1532, 1533, 83 vVestern Center for Technical Studies 1623, 1624, 1625, 1626, 4390, 4389, 999, 4163, 1122, 1129, 4166, 1127, 1128, 1188, 1107, 1143, 1153, 1116, 1154, 1155, 562, 4368, 563, 564 84 Woodland Elementary School 3083, 4155, 775 1341, 1342, 1343, 1344, 1346, 1411, 1410, 4413, 85
- oventry Manor Nursing Home 10,10,10,10 1409, 1408, 14073,1402 86 I~t. Gabriel's Good Shepherd Learning Ctr 26, 3941, 4440, 23, 22, 21, 20 8-37 KLD Engineering, P.C.
Limerick Generating Station Evacuation Time Estimate 8-37 KLD Engineering, P.C.
Rev. 0
Bs.I 87 Amity Primary Center 398,399,400 751, 752, 753, 754, 1612, 3882, 755, 756, 4176, 1593, 1777, 1619, 1785, 1786, 1787, 1783, 1784, 1559, 1560, 1561, 1562, 1563, 1564, 1565, 1566, 1567,1568,1569,1570,1571 1698, 1601, 3325, 1611, 1610, 1609, 3879, 1600, 1608, 1607, 1606, 3886, 3884, 756, 4176, 1593, 89 Royersford Route 1777, 1619, 1785, 1786, 1787, 1783, 1784, 1559, 1560, 1561, 1562, 1563, 1564, 1565, 1566, 1567, 1568,1569,1570,1571 639, 4165, 976, 975, 974, 977, 978, 979, 980, 981, 548, 994, 950, 989, 995, 990, 996, 997, 998, 4161, 4162, 999, 4389, 4390, 1626, 1625, 1624, 1623, 1533, 1532, 1622, 1621, 1555, 1556, 1557, 1558, 1559, 1560, 1561, 1562, 1563, 1564, 1565, 1566, 1567,1568,1569,1570,1571 35, 971, 972, 973, 974, 977, 978, 979, 980, 981, 548, 994, 950, 989, 995, 990, 996, 997, 998, 4161, 91 New Hanover Route 4162, 999, 4389, 4390, 1626, 1625, 1624, 1623, 1533, 1532, 1622, 1621, 1555, 1556, 1557, 1558, 1559, 1560, 1561, 1562, 1563, 1564, 1565, 1566, 1567,1568,1569,1570,1571 871, 873, 874, 875, 876, 877, 878, 879, 880, 883, 884, 885, 968, 892, 893, 987, 635, 971, 972, 973, 974, 977, 978, 979, 980, 981, 548, 994, 950, 989, 92 Pottstown Route 95, 990, 996, 997, 998, 4161, 4162, 999, 4389, 4390, 1626, 1625, 1624, 1623, 1533, 1532, 1622, 1621, 1555, 1556, 1557, 1558, 1559, 1560, 1561, 1562, 1563, 1564, 1565, 1566, 1567, 1568, 1569, 1570,1571 28, 829, 454, 3933, 455, 456, 727, 457, 458, 459, 460, 461, 462, 463, 464, 465, 3806, 3801, 3802, 639, 4165, 976, 975, 974, 977, 978, 979, 980, 981, 948, 994, 950, 989, 995, 990, 996, 997, 998, 4161, 9162, 999, 4389, 4390, 1626, 1625, 1624, 1623, 1533, 1532, 1622, 1621, 1555, 1556, 1557, 1558, 1559, 1560, 1561, 1562, 1563, 1564, 1565, 1566, 1567,1568,1569,1570,1571 8-38 KLD Engineering, P.C.
Limerick Generating Station Evacuation Time Estimate 8-38 KLD Engineering, P.C.
Rev. 0
Bus 94 Upper Pottsgrove Route 360, 861, 3796, 3797, 3798, 3799, 3800, 3801, 3802, 639, 4165, 976, 975, 974, 977, 978, 979, 980, 381, 548, 994, 950, 989, 995, 990, 996, 997, 998, 4161, 4162, 999, 4389, 4390, 1626, 1625, 1624, 1623, 1533, 1532, 1622, 1621, 1555, 1556, 1557, 1558, 1559, 1560, 1561, 1562, 1563, 1564, 1565, 1566, 1567, 1568, 1569, 1570, 1571 307, 908, 935, 936, 937, 960, 961, 959, 962, 963, 364, 892, 893, 987, 635, 971, 972, 973, 974, 977,
)78, 979, 980, 981, 548, 994, 950, 989, 995, 990, 95 Lower Pottsgrove Route 396, 997, 998, 4161, 4162, 999, 4389, 4390, 1626, 1625, 1624, 1623, 1533, 1532, 1622, 1621, 1555, 1556, 1557, 1558, 1559, 1560, 1561, 1562, 1563, 1564, 1565, 1566, 1567, 1568, 1569, 1570, 1571 66, 67, 68, 69, 70, 87, 88, 71, 72, 73, 3367, 3070, 96 Upper Providence 2 South Route 3085, 3383, 3090, 4156, 3089, 3101, 3102, 3103, 3104, 774, 3001 97 Lower Providence 1 Route 769, 1997, 1998, 1999, 3000 98 Lower Providence 2 Route 4157, 3376, 4454, 3083, 4155, 775, 3002 758, 1721, 759, 760, 761, 1771, 4538, 1767, 1836, 99 Upper Providence 1 North Route 1835, 1837, 1838, 1839, 1840, 1841, 1842, 1566, 1567, 1568, 1569, 1570, 1571 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 70, 87, 88, 71, 100 Limerick 2 South Route 72, 73, 3367, 3070, 3085, 3383, 3090, 4156, 3089, 3101, 3102, 3103, 3104, 774, 3001 1838, 1839, 1840, 1841, 1842, 1566, 1567, 1568, 101
- kippack 1 Fast Route 16,17,17 1569, 1570, 1571 1787, 1783, 1784, 1559, 1560, 1561, 1562, 1563, 1564, 1565, 1566, 1567, 1568, 1569, 1570, 1571 1555, 1556, 1557, 1558, 1559, 1560, 1561, 1562, 103 Schwenskville Route 1563, 1564, 1565, 1566, 1567, 1568, 1569, 1570, 1571 104 Upper Salford 1660, 1664, 1789, 1540, 1790 105 Upper Uwchlan SE Route 1315, 3979, 3977, 1316, 1317, 1318 927, 934, 896, 897, 898, 899, 3829, 3304, 1223, 106 Warwick Child Care North Coventry Ctr 1192, 1193, 1194, 1195, 1196, 1197, 1198, 1199, 1200, 1201, 1202, 1203, 3293 8-39 KLD Engineering, P.C.
Limerick Generating Station Evacuation Time Estimate 8-39 KLD Engineering, P.C.
Rev. 0
Bus.
6 107 Douglassville Children's Center 395, 396, 397, 398, 399, 400 108 Douglassville KinderCare 393, 394, 4439, 395, 396, 397, 398, 399, 400 109 St. Gabriel's Good Shepherd Learning Ctr 26, 3941, 4440, 23, 22, 21, 20 110 Gail Swartz Family Daycare 1358, 1203, 3293 111 St. John's Lutheran Church 413, 430, 431, 432, 433, 547, 434, 435, 436 112 Saint Columbkill Preschool 416, 415, 431, 432, 433, 547, 434, 435, 436 3808, 647, 648, 649, 650, 651, 413, 430, 431, 432, 113 Almost Home Children's Center 3
4 3
3 3
433, 547, 434, 435, 436 114 Teresa Walter Family Daycare 694, 421, 405 1415, 1416, 1417, 3845, 1229, 1230, 1231, 1232, 3853, 3855, 1233, 3411, 3412, 3413, 3414, 3415, 115 Grace Assembly of God Day Care 3416, 3417, 3418, 3419, 3420, 3421, 3422, 3423, 3424, 3425, 3426, 3427, 3428, 3433, 3432, 3429, 3430 3860, 4428, 3390, 3861, 4547, 4546, 3862, 3863, 116 International Montessori 430, 4426, 3395, 3396, 3397, 3398, 3399, 3400, 3401, 3402, 3403, 3404, 3901 1239, 1240, 1241, 1242, 1243, 1244, 1245, 1246, 117 Phoenixville Area YMCA Child Care Center 14,14,14 1247, 1248, 1249 3347, 3848, 3348, 3388, 3858, 3860, 4428, 3390, 118 Stepping Stone Education Center 3861, 4547, 4546, 3862, 1239, 1240, 1241, 1242, 1243, 1244, 1245, 1246, 1247, 1248, 1249 119 Magic Memories 1241, 1242, 1243, 1244, 1245, 1246, 1247, 1248, 1249 120 Valley Forge Kinder House Montessori,426, 3395, 3396, 3397, 3398, 3399, 3400, 3401, School 3402, 3403, 3404, 3901 121 Kiddie Academy 3411, 3510, 3497, 3395, 3396, 3397, 3398, 3399, 3400, 3401, 3402, 3403, 3404, 3901 1704, 4435, 1227, 4425, 4424, 1228, 3844, 1229, 1230, 1231, 1232, 3853, 3855, 1233, 3411, 3412, 122 Kids Kare Korner 3413, 3414, 3415, 3416, 3417, 3418, 3419, 3420, 3421, 3422, 3423, 3424, 3425, 3426, 3427, 3428, 3433, 3432, 3429, 3430 Limerick Generating Station Evacuation Time Estimate 8-40 KLD Engineering, P.C.
Rev. 0
Bus 3
6.6 6
123 KinderCare Phoenixville (No.1405)
L230, 1231, 1232, 3853, 3855, 1233, 3411, 3412, 3413, 3414, 3415, 3416, 3417, 3418, 3419, 3420, 3421, 3422, 3423, 3424, 3425, 3426, 3427, 3428, 3433,3432,3429,3430 1190,1191,927,934,896,3303,3831,1283,1284, 1285, 1286, 1287, 1288, 1289, 4434, 1290, 1291, 1292, 1345, 1347, 1346, 1411, 1410, 4413, 1409, 1408,1407,1402 125 Our Place to Grow (Children's House) 1346,1411,1410,4413,1409,1408,1407,1402 1347, 1346, 1411, 1410, 4413, 1409, 1408, 1407, 126 Pottstown YMCA French Creek Elementar 1402 127 Warwick Child Care - South Coventry Ctr 1345, 1347, 1346, 1411, 1410, 4413, 1409, 1408, 1407,1402 1189, 1224, 3559, 3560, 3561, 3562, 3563, 3564, 128 East Coventry Elementary 1414, 1413, 3565, 1412, 1292, 1345, 1347, 1346, 1411,1410,4413,1409,1408,1407,1402 1414, 3833, 1415, 1416, 1417, 3845, 1229, 1230, 1231, 1232, 3853, 3855, 1233, 1234, 1235, 1236, 129 Collegeville Montessori Academy 1237, 1238, 3862, 1239, 1240, 1241, 1242, 1243, 1244, 3382, 3093, 3092, 3091, 3090, 4156, 3089, 3101,3102,3103,3104,774,3001 130 Bright Spot Child Care 765, 766, 767, 768, 4392, 1997, 1998, 1999, 3000 131 Play and Learn - Collegeville 769, 1997, 1998, 1999, 3000 132 Play and Learn - Green Lane 1156, 4394, 1157, 1152, 1664, 1789, 1540, 1790 759,760,761,1771,4538,1767,1836,1835,1837, 133 Twin Acres County Day School 1838, 1839, 1840, 1841, 1842, 1566, 1567, 1568, 1569,1570,1571 1604, 59, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 70, 134 Country Tyme Day Care 87, 88, 71, 72, 73, 3367, 3070, 3085, 3383, 3090, 4157,3376,4454,3083,4456 1707, 1611, 1610, 63, 64, 65, 66, 67, 68, 69, 70, 87, 135
- pring-Ford 7th Grade Center8,7,7,3,4,5,6,7,8,9,0 88,71,72,73,74,75,76,77,78,79,80 751, 752, 753, 754, 1612, 3882, 755, 756, 757, 3887, 758, 1721, 759, 760, 761, 4463, 762, 4384, 763, 764, 765, 766, 767, 768, 4392, 1997, 1998, 1999,3000 Limerick Generating Station Evacuation Time Estimate 8-41 KLD Engineering, P.C.
Rev. 0
Bus 0
137 Jessie R. Wagner Adventist Elementarn School 700, 712, 713, 714, 715, 716, 717, 3939, 32, 3940, 30, 27, 26, 3941, 4440, 23, 22, 21, 20 138 New Life Youth & Family Services 1542, 1814, 1805, 1806 932, 3823, 4493, 933, 3824, 873, 874, 875, 876, 139 The Hill School 877, 878, 879, 880, 883, 884, 885, 968, 892, 893, 1l87, 635, 971, 972, 973, 974, 977, 552, 1035, 1036, 1037, 625, 4382 3497, 3395, 3396, 3397, 3398, 3399, 3400, 3401, 140 Center for Arts and Technology-Pickering 40,33,44,58,94 3402, 3403, 3404, 3508, 3904 854, 857, 858, 457, 458, 459, 460, 461, 462, 463, 141 Lincoln Elementary School 464, 465, 3805, 466, 467, 468, 469, 470, 471, 472, 473, 474, 475, 476, 477 3861, 4547, 4546, 3862, 3863, 4430, 4426, 3395, 142 Holy Family School 3396, 3397, 3398, 3399, 3400, 3401, 3402, 3403, 3404, 3508, 3904 3789, 3415, 3416, 3417, 3418, 3419, 3420, 3421, 143 St. Basil the Great School 3422, 3423, 3424, 3425, 3426, 3427, 3512, 3513, 3514 144 Ursinus College 763, 764, 765, 766, 767, 768, 4392, 1997, 1998, 1999, 3000 896, 897, 898, 1280, 452, 451, 453, 454, 3933, 455, 1r56, 727, 457, 458, 459, 460, 461, 462, 463, 464, 1r65, 3805, 466, 467, 468, 469, 470, 471, 472, 473, 474, 475, 476, 477 1730, 3333, 3338, 3341, 3339, 3041, 1734, 1735, 146 Valley Forge Baptist Temple Academy 1736, 3877, 3869, 3872, 1737, 3867, 1738, 3874, 765, 766, 767, 768, 4392, 1997, 1998, 1999, 3000 3497, 3395, 3396, 3397, 3398, 3399, 3400, 3401, 3402, 3403, 3404, 3508, 3904 1a88, 554, 555, 679, 680, 681, 682, 630, 629, 628, 148 Perkiomen Valley Academy 2,66 2,48 627, 626, 625, 4382 3784, 3782, 3786, 3787, 3788, 3790, 3418, 3419, 149 Kimberton-Waldorf School 3420, 3421, 3422, 3423, 3424, 3425, 3426, 3427, 3512, 3513, 3514 150 Upattinas Open Community School 791, 3792, 3793 Limerick Generating Station Evacuation Time Estimate 8-42 KLD Engineering, P.C.
Rev. 0
Bus Route Nodes Traversed from Route Start to EPZ Number Description Boundary kt. Gabriel's Hall 3092, 3091, 3378, 3379, 3373, 4393, 3084, 3381, M
79,80 1
152
,tria Woodbridge Place 3415, 3416, 3417, 3418, 3419, 3420, 3421, 3422, 3423, 3424, 3425, 3426, 3427, 3428, 3433, 3432, 3429,3430 153 Chestnut Knoll Assisted Living 430,431,432,433,547,434,435,436 1341, 1342, 1343, 1344, 1346, 1411, 1410, 4413, 154 Coventry Manor Nursing Home 10,10,10,10 1409,1408,1407,1402 155 Eagleville Hospital 3082, 771, 772, 773, 774, 775, 4155, 3083, 3377, 3922,3374,3373,4393,3084,3381,79,80 464, 465, 3805, 466, 467, 644, 645, 646, 647, 648, 156 Wayside Christian School 649, 650, 651, 413, 430, 431, 432, 433, 547, 434, 435,436 157 Colonial Manor Adult Home 1199,1200,1201,1202,1203,3293 1107, 1143, 1153, 1116, 1154, 1155, 562, 4395, 1156,4394,1157,1152,1664,1789,1540,1790 737, 801, 802, 803, 804, 805, 806, 807, 908, 935, 159 Sanatoga Center 936, 937, 960, 961, 959, 962, 963, 964, 892, 893, 987,635,971,972,973,974,977,552,1035,1036, 1037,625,4382 160 Genesis Healthcare 3417, 3418, 3419, 3420, 3421, 3422, 3423, 3424, 3425,3426,3427,3428,3433,3432,3429,3430 4430, 4426, 3395, 3396, 3397, 3398, 3399, 3400, 3401,3402,3403,3404,3508,3904 877, 878, 879, 880, 883, 884, 885, 968, 892, 893, 162 HCR ManorCare 987,635,971,972,973,974,977,552,1035,1036, 1037,625,4382 163 Hearthstone at Amity 27,26,3941,4440,23,22,21,20 164 Keystone Villa at Douglassville 25,28,27,26,3941,4440,23,22,21,20 1190,1191,927,934,896,3303,3831,1283,1284, 1285, 1286, 1287, 1288, 1289, 4434, 1290, 1291, 1292, 1345, 1347, 1346, 1411, 1410, 4413, 1409, 1408,1407,1402 3349, 1729, 1730, 3350, 1731, 3865, 1732, 3340, 166 Parkhouse Providence Pointe 68, 69, 70, 87, 88, 71, 72, 73, 74, 75, 76, 77, 78, 79, 80 8-43 KLD Engineering, P.C.
Limerick Generating Station Evacuation Time Estimate 8-43 KLD Engineering, P.C.
Rev. 0
Bus 0
0.0 0
167 Phoenixville Hospital 3862, 3863, 4430, 4426, 3395, 3396, 3397, 3398, 3399,3400,3401,3402,3403,3404,3508,3904 3376, 3377, 3922, 3374, 3373, 4393, 3084, 3381, 168 Shannondell at Valley Forge9,8 79,80 1225, 1226, 1227, 4425, 4424, 1228, 3844, 1229, 1230, 1231, 1232, 3853, 3855, 1233, 3411, 3412, 169 Southeastern Veterans Center 3413, 3414, 3415, 3416, 3417, 3418, 3419, 3420, 3421, 3422, 3423, 3424, 3425, 3426, 3427, 3428, 3433,3432,3429,3430 810,3312,4475,931,930,3311,48,47,46,45,44, 170 Pottstown Memorial Medical Center 43, 42, 41, 40, 39, 38, 37, 36, 35, 848, 34, 33, 31, 3940,30,27,26,3941,4440,23,22,21,20 Limerick Generating Station Evacuation Time Estimate 8-44 KLD Engineering, P.C.
Rev. 0
Table 8-7. School Evacuation Time Estimates - Good Weather Amitv Elementary Center 90 15 4.5 1.8 I.
I Boyertown Area High School 90 15z 3.4 2.6 79 Boyertown Area Junior High School West 90 15 3.8 3.0 77 Boyertown Elementary School 90 15 3.8 3.0 77 Brookeside Montessori 90 15 2.2 4.5 29 Colebrookdale Elementary School 90 15 4.0 2.7 88 Daniel Boone Middle School 90 15 7.0 30.2 14 Jessie R. Wagner Adventist Elementary School 90 15 6.1 2.0 179 Monocacy Elementary Center 90 15 0.8 40.0 1
Pine Forge Elementary School 90 15 3.3 1.5 128 Barkley Elementary School 90 15 4.7 5.6 50 Center for Arts and Technology-Pickering Campus 90 15 4.9 12.0 25 Charlestown Elementary School 90 15 0.4 3.6 7
Collegeville Montessori Academy 90 15 15.4 4.7 195 East Coventry Elementary School 90 15 13.4 16.1 50 East Pikeland Elementary School 90 15 6.3 8.4 45 East Vincent Elementary School 90 15 10.4 13.3 47 French Creek Elementary School 90 15 6.0 9.9 37 Holy Family School 90 15 4.5 7.3 37 Kimberton-Waldorf School 90 15 7.4 13.4 33 Kindergarten Center 90 15 4.6 7.1 39 Montgomery School 90 15 2.2 40.5 3
North Coventry Elementary School 90 15 10.3 10.9 57 Owen J. Roberts High School 90 15 7.5 10.6 42 Owen J. Roberts Middle School 90 15 7.3 10.6 41 17.3 14.9 14.9 14.9 20.9 14.9 7.0 33.1 2.2 17.3 19 16 16 16 23 16 8
36 2
4.2 7.1 2.1 6.3 3.4 4.2 3.4 3.4 5.6 16.9 6.5 7.2 3.4 4.4 4.4 5
8 2
7 4
5 4
4 6
18 7
8 4
5 5
Limerick Generating Station Evacuation Time Estimate 8-45 KLD Engineering, P.C.
Rev. 0
Phoenixville Area High School 90 15 3.5 7.6 28 Phoenixville Area Middle School 90 15 3.6 7.6 28 Pickering Valley Elementary School 90 15 1.0 2.1 28 Renaissance Academy 90 15 5.3 11.8 27 Schuylkill Elementary School 90 15 2.5 8.4 18 Spring City Elementary School 90 15 12.1 6.4 113 St. Basil the Great School 90 15 7.3 9.9 44 Upattinas Open Community School 90 15 1.3 3.3 23 Valley Forge Christian College 90 15 5.0 12.0 25 est Vincent Elementary School 90 15 7.7 42.4 11 6est-Mont Christian Academy 90 15 11.3 3.2 213 Arcola Intermediate School 90 15 2.8 2.0 85 Arrowhead Elementary School 90 15 4.7 2.0 144 Audubon Elementary 90 15 1.2 8.1 9
Blessed Theresa of Calcutta 90 15 11.6 8.9 78 Boyertown Area Junior High School East 90 15 6.7 3.3 122 Bright Spot Kindergarten 90 15 3.7 1.4 154 Brooke Elementary School 90 15 11.4 3.3 209 Chapel Christian Academy 90 15 10.2 2.9 209 Coventry Christian Schools 90 15 11.2 10.4 64 Eagleville Elementary School 90 15 0.6 2.7 13 Edgewood Elementary School 90 15 9.7 3.0 192 Elizabeth B. Barth Elementary School 90 15 10.7 3.1 207 Evans Elementary School 90 15 9.4 2.9 196 Evergreen Elementary School 90 15 6.1 10.6 34 Franklin Elementary School 90 15 10.1 3.0 202 Gilbertsville Elementary School 90 15 4.8 2.5 117 Limerick Elementary School 90 15 8.8 2.8 188 4.2 4.2 7.2 12.2 4.2 12.7 7.8 16.9 12.2 3.4 5
5 8
13 S
14 9
18 13 4
ini 11 LU.J 2.4 3.0 6.2 14.9 7.8 6.2 8.8 2.2 3.1 13.2 13.2 6.2 4.8 LL 3
3 7
16 9
7 10 2
3 14 14 7
5 13.2 14.9 9.5 14 16 10 Limerick Generating Station Evacuation Time Estimate 8-46 KLD Engineering, P.C.
Rev. 0
LinCOln tilemeniary acnool Z./
LIfl~0Ifl l:Iementiry ~cnooI L.I Lower Pottsgrove Elementary School 1 93 1 4.
1 New Hanover-Upper Frederick Elementary School 90 15 5.9 2.4 146 New Life Youth & Family Services 90 15 1.2 29.0 2
Oaks Elementary School 90 15 4.6 5.0 55 Perkiomen Valley Academy 90 15 4.5 39.2 7
Perkiomen Valley High School 90 15 6.0 10.0 36 Perkiomen Valley Middle School - East 90 15 6.2 10.6 35 Perkiomen Valley Middle School -West 90 15 8.8 11.3 47 Perkiomen Valley South Elementary School 90 15 3.7 8.2 27 Pope John Paul II High School 90 15 9.4 13.8 41 Pottsgrove High School 90 15 8.7 4.1 126 Pottsgrove Middle School 90 15 9.7 4.5 130 Pottstown High School 90 15 9.9 2.9 203 Pottstown Middle School 90 15 10.4 3.1 205 Ringing Rocks Elementary 90 15 8.7 4.1 126 Royersford Elementary School 90 15 11.8 6.2 115 Rupert Elementary School 90 15 12.4 3.6 205 Sacred Heart School 90 15 10.1 6.2 98 Salford Hills Elementary 90 15 1.9 17.1 7
Schwenksville Elementary School 90 15 6.1 8.2 45 Skippack Elementary School 90 15 3.1 10.0 19 Skyview Upper Elementary School 90 15 0.0 0.0 0
Spring-Ford Sth-6th Grade Center 90 15 9.9 6.2 96 Spring-Ford 7th Grade Center 90 15 10.5 6.2 101 Spring-Ford 8th Grade Center 90 15 10.6 6.2 102 Spring-Ford Senior High School 10-12 Grade Center 90 15 10.1 6.2 98 Spring-Ford Senior High School 9th Grade Center 90 15 10.9 6.2 105 St. Aloysius 90 15 9.7 3.5 167 114.U 16.6 18.5 20.8 12.7 36.1 4.8 4.8 4.8 8.3 17.0 16.6 16.6 13.2 13.2 16.6 6.2 13.2 12.4 2.3 4.8 4.8 2.1 6.2 6.2 6.2 6.2 6.2 16.1 J.L:
18 20 23 14 39 5
5 5
9 19 18 18 14 14 18 7
14 14 3
5 5
2 7
7 7
7 7
18 Limerick Generating Station Evacuation Time Estimate 8-47 KLD Engineering, P.C.
Rev. 0
- 51. tieanor bcnooi 15 8.9 3.8 142 St. Gabriel's Hall 90 15 2.5 2.2 69 St. Mary's School 90 15 2.7 28.1 6
St. Peter's Lutheran Church - School 90 15 10.9 3.1 212 The Hill School 90 15 11.2 4.6 147 Upper Providence Elementary School 90 15 9.7 6.1 95 Ursinus College 90 15 3.1 1.4 133 Valley Forge Baptist Temple Academy 90 15 6.1 1.9 198 Wayside Christian School 90 15 5.5 2.7 123 West Pottsgrove Elementary School 90 15 14.0 5.3 158 Western Center for Technical Studies 90 15 10.5 31.6 20 Woodland Elementary 90 15 1.1 4.3 15 Wyndcroft School 90 15 10.3 3.1 198 Maximum for EPZ; Avrg for EPZ:
Almost Home Children's Center 90 15 3.8 2.4 94 Boyertown Area YMCA 90 15 3.4 2.8 72 Douglassville Children's Center 90 15 2.1 7.3 17 Douglassville KinderCare 90 15 2.8 6.0 28 Gail Swartz Family Daycare 90 15 0.2 29.1 0
Saint Columbkill Preschool 90 15 2.8 2.5 67 St. Gabriel's Good Shepherd Learning Center 90 15 2.8 3.8 44 St. John's Lutheran Church 90 15 3.0 2.8 65 Pt. Paul's Day Care
_90 15 1_4.1 7.1 1
_34 Brigh lt Early Lear e
90 15 1.0 5.3 11 Bright Light Early Learning Center 90 15 0.5 8.04 2.9 20.3 7.4 13.5 32.8 6.2 22.3 5.3 7.0 16.6 6.2 2.4 17.8 3
22 8
15 36 7
24 6
8 18 7
3
/.U 3.4 2.1 7.0 6.7 7.0 2.8 7.0 4.1 4
2 8
7 8
3 8
4 7
/.Z I
ts Limerick Generating Station Evacuation Time Estimate 8-48 KLD Engineering, P.C.
Rev. 0
Children's House of Northern Chester County 90 15 5.1 9.6 32 East Coventry Elementary School 90 15 13.4 16.1 50 Grace Assembly Day Care Center 90 15 12.6 4.4 173 International Montessori 90 15 4.8 6.5 45 Kiddie Academy 90 15 5.4 9.8 33 Kids Kare Korner 90 15 12.2 4.8 153 Kindercare Learning Center No. 1405 90 15 9.6 6.3 92 Little Angels Day Care 90 15 5.0 6.5 46 Magic Memories 90 15 4.9 8.8 33 Our House Early Learning Center 90 15 12.8 10.1 76 Phoenixville Area Children Learning Center 90 15 4.6 6.4 43 Phoenixville Area Children's Learning Center 2 90 15 5.0 4.3 70 Phoenixville Area YMCA Child Care Center 90 15 4.6 8.0 35 Pottstown YMCA French Creek Elementary 90 15 6.0 9.9 37 Stepping Stone Education Center 90 15 5.0 4.3 70 Teach & Learn Day School 90 15 8.3 5.8 85 The Goddard School - Chester Springs 90 15 0.8 7.6 6
Valley Forge Kinder House Montessori School 90 15 3.9 12.4 19 Warwick Child Care - North Coventry Center 90 15 6.9 8.8 47 Warwick Child Care - South Coventry Center 90 15 6.5 9.8 40 Boyertown Children's Center 90 15 17.9 13.8 78 Bright Beginnings Child Care Center 90 15 10.2 8.3 74 Bright Spot Child Care 90 15 3.7 1.5 149 Chesterbrook Academy - Collegeville 90 15 1.4 1.9 45 Chesterbrook Academy - Limerick 90 15 13.5 5.5 148 Chesterbrook Academy - Norristown 90 15 2.9 5.9 29 Chesterbrook Academy - Phoenixville 90 15 6.9 4.6 90 Chesterbrook Academy - Royersford 90 15 11.4 5.2 131 10.9 5.4 3.3 12.2 12.2 3.3 3.3 12.2 12.2 5.4 12.2 12.2 12.2 4.2 12.2 3.3 7.2 12.2 5.4 12 6
4 13 13 4
4 13 13 6
13 13 13 5
13 4
8 13 6
O0.
6.2 7.8 8.1 6.6 7.4 6.6 6.6 I
7 9
9 7
8 7
7 Limerick Generating Station Evacuation Time Estimate 8-49 KLD Engineering, P.C.
Rev. 0
iiiaren of America I rappe I.!
F_
-- A
- ountry Tyme Day Care 90 15 11.5 5.4 129
- oventry Christian Pre-School 90 15 11.2 7.2 93
- reative Beginnings Preschool 90 15 1.2 1.9 39
- reative Child Care Too 90 15 3.4 1.7 117 Creative Minds Montessori 90 15 19.3 11.4 102 Dotlen Academy 90 15 20.7 8.0 155 Flanagan's Pre-School 90 15 5.9 9.0 39 FV YMCA - Audubon Elementary 90 15 1.2 5.6 13 FV YMCA - Brooke Elementary School 90 15 11.4 5.2 131 FV YMCA - Evans Elementary School 90 15 9.4 8.3 68 FV YMCA - Limerick Elementary School 90 15 8.8 7.6 69 FV YMCA - Perkiomen Valley Middle School 90 15 6.2 6.8 55 FV YMCA - Pottstown Day Care 90 15 20.0 8.0 149 FV YMCA - Royersford Elementary School 90 15 11.8 9.2 77 FV YMCA - Spring Valley 90 15 9.3 8.3 68 FV YMCA - Woodland Elementary 90 15 1.1 5.6 12 Hendricks Family Growing Dreams 90 15 14.6 8.8 100 Jerusalem Lutheran Day Care Center 90 15 6.2 8.6 43 Kiddie Academy Collegeville 90 15 7.7 7.5 62 Kiddie Academy Royersford 90 15 13.1 5.5 144 Kids Kare Korner III 90 15 11.6 9.2 76 Kinder Works 90 15 10.2 8.3 74 Kindercare 3056 90 15 22.0 9.6 137 Kindercare 3060 90 15 9.0 4.7 115 Little Faces Learning Center 90 15 16.2 13.1 74 Little Footprints 90 15 23.9 7.2 198 Little Mary Daycare 90 15 20.7 8.0 155 Montgomery Early Learning Center 90 15 20.6 8.0 154 O.Z 5.4 2.2 8.1 8.1 6.2 6.2 6.2 3.0 6.2 6.2 9.5 4.8 6.2 6.2 6.2 2.4 6.2 6.2 6.2 6.6 6.2 6.2 6.2 6.6 6.2 6.2 6.2 6.2 I
6 2
9 9
7 7
7 3
7 7
10 5
7 7
7 3
7 7
7 7
7 7
7 7
7 7
7 7
Limerick Generating Station Evacuation Time Estimate 8-50 KLD Engineering, P.C.
Rev. 0
New Hanover Child Care 90 15 15.7 8.9 106 North Penn YMCA - Salford Hills Elementary 90 15 1.9 18.7 6
North Penn YMCA - Schwenksville Elementary 90 15 6.1 8.2 45 Oaks Early Learning 90 15 5.3 4.5 70 Phoenixville Area YMCA - Eagleville Elementary 90 15 0.6 1.5 24 Phoenixville Area YMCA-Arrowhead Elementary 90 15 4.7 1.9 147 Phoenixville Area YMCA-Oaks Elementary School 90 15 4.6 4.4 63 Play and Learn - Collegeville 90 15 1.6 1.9 51 Play and Learn - Green Lane 90 15 3.2 25.4 8
Play and Learn - Royersford 90 15 10.0 4.7 127 Providence Christian Preschool 90 15 9.6 4.7 123
$El Family Center 90 15 5.0 4.5 67 Short Stuff & Co 90 15 0.9 5.5 10 Spring Valley YMCA Child Care Facility 90 15 11.3 8.5 80 Sunny Dayz Child Care 90 15 20.7 8.0 155 The Goddard School - Gilbertsville 90 15 16.8 13.1 77 The Goddard School - Royersford 90 15 11.0 8.5 77 The Goddard School - Sanatoga 90 15 20.7 9.4 133 The Goddard School - Schwenksville 90 15 6.2 6.8 55 The Goddard School - Skippack 90 is 2.3 6.6 21 The Learning Experience 90 15 20.7 9.4 133 The Malvern School - Collegeville 90 15 3.4 1.7 117 The Malvern School - Royersford 90 15 13.0 5.5 143 The Malvern School of Oaks 90 15 6.0 4.5 79 Tot Spot Learning Center 90 15 4.3 1.8 144 Twin Acres Country Day School 90 15 7.8 5.1 92 Tykes and Tots Day Care 90 15 3.1 7.2 26 Valley Forge Children's Academy 90 15 1.8 5.6 19 Victory Early Learning Academy 90 15 1.5 5.6 16 6.2 2.3 4.8 6.6 3.1 2.4 12.7 15.8 23.9 6.6 6.6 6.6 7.0 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 8.1 6.6 6.6 8.1 4.4 6.2 8.2 8.7 7
3 5
7 3
3 14 17 26 7
7 7
8 7
7 7
7 7
7 7
7 9
7 7
9 5
7 9
9 Limerick Generating Station Evacuation Time Estimate 8-51 KLD Engineering, P.C.
Rev. 0
IYMCA Growing Dreams Child Care Center 8-52 KLD Engineering, P.C.
Limerick Generating Station Evacuation Time Estimate 8-52 KLD Engineering, P.C.
Rev. 0
Table 8-8. School Evacuation Time Estimates - Rain Amity Elementary Center 20 4.5 1.9 Boyertown Area High School 1
20 3.4 2.4 84 Boyertown Area Junior High School West 100 20 3.8 2.8 82 Boyertown Elementary School 100 20 3.8 2.8 82 Brookeside Montessori 100 20 2.2 3.2 41 Colebrookdale Elementary School 100 20 4.0 2.7 89 Daniel Boone Middle School 100 20 7.0 31.5 13 Jessie R. Wagner Adventist Elementary School 100 20 6.1 2.0 185 Monocacy Elementary Center 100 20 0.8 36.0 1
APine Forge Elementary School 100 20 3.3 1.6 127 Barkley Elementary School 100 20 4.7 6.1 46 Center for Arts and Technology-Pickering Campus 100 20 4.9 11.0 27 Charlestown Elementary School 100 20 0.4 3.3 7
Collegeville Montessori Academy 100 20 15.4 4.3 213 East Coventry Elementary School 100 20 13.4 14.7 55 East Pikeland Elementary School 100 20 6.3 7.8 48 East Vincent Elementary School 100 20 10.4 12.3 51 French Creek Elementary School 100 20 6.0 8.8 41 Holy Family School 100 20 4.5 7.2 37 Kimberton-Waldorf School 100 20 7.4 10.5 42 Kindergarten Center 100 20 4.6 7.5 37 Montgomery School 100 20 2.2 18.8 7
North Coventry Elementary School 100 20 10.3 9.5 65 Owen J. Roberts High School 100 20 7.5 9.9 45 Owen J. Roberts Middle School 100 20 7.3 9.9 44 17.3 14.9 14.9 14.9 20.9 14.9 7.0 33.1 2.2 17.3 21 18 18 18 25 18 8
40 3
7.1 2.1 6.3 3.4 4.2 3.4 3.4 5.6 16.9 6.5 7.2 3.4 4.4 4.4 5
9 3
8 4
5 4
4 7
20 8
9 4
5 5
Limerick Generating Station Evacuation Time Estimate 8-S3 KLD Engineering, P.C.
Rev. 0
Phoenixville Area High School 100 20 3.5 8.3 25 Phoenixville Area Middle School 100 20 3.6 8.3 26 Pickering Valley Elementary School 100 20 1.0 2.4 25 Renaissance Academy 100 20 5.3 11.0 29 Schuylkill Elementary School 100 20 2.5 8.5 18 Spring City Elementary School 100 20 12.1 5.6 129 St. Basil the Great School 100 20 7.3 8.4 52 Upattinas Open Community School 100 20 1.3 11.0 7
Valley Forge Christian College 100 20 5.0 11.0 27 West Vincent Elementary School 100 20 7.7 41.4 11 West-Mont Christian Academy 100 20 11.3 3.2 215 Arcola Intermediate School 100 20 2.8 2.9 59 Arrowhead Elementary School 100 20 4.7 2.3 124 Audubon Elementary 100 20 1.2 6.5 11 Blessed Theresa of Calcutta 100 20 11.6 8.3 83 Boyertown Area Junior High School East 100 20 6.7 3.0 132 Bright Spot Kindergarten 100 20 3.7 1.5 149 Brooke Elementary School 100 20 11.4 3.4 201 Chapel Christian Academy 100 20 10.2 3.1 200 Coventry Christian Schools 100 20 11.2 8.6 78 Eagleville Elementary School 100 20 0.6 2.6 14 Edgewood Elementary School 100 20 9.7 2.9 198 Elizabeth B. Barth Elementary School 100 20 10.7 2.9 218 Evans Elementary School 100 20 9.4 2.7 208 Evergreen Elementary School 100 20 6.1 9.3 39 Franklin Elementary School 100 20 10.1 3.0 202 Gilbertsville Elementary School 100 20 4.8 2.4 119 Limerick Elementary School 100 20 8.8 2.8 187 4.2 4.2 7.2 12.2 4.2 12.7 7.8 16.9 12.2 3.4 5
5 9
15 5
15 9
20 15 4
L"U.3 2.4 3.0 6.2 14.9 7.8 6.2 8.8 2.2 3.1 13.2 13.2 6.2 4.8 13.2 14.9 9.5 3
4 7
18 9
7 11 3
4 16 16 7
6 16 18 11 Limerick Generating Station Evacuation Time Estimate 8-54 KLD Engineering, P.C.
Rev. 0
Lincoln Elementary School 100 20 8.8 2.7 196 Lower Pottsgrove Elementary School 100 20 9.3 4.3 131 New Hanover-Upper Frederick Elementary School 100 20 5.9 2.4 145 New Life Youth & Family Services 100 20 1.2 29.0 2
Oaks Elementary School 100 20 4.6 4.0 68 Perkiomen Valley Academy 100 20 4.5 16.2 17 Perkiomen Valley High School 100 20 6.0 8.9 41 Perkiomen Valley Middle School - East 100 20 6.2 10.0 37 Perkiomen Valley Middle School -West 100 20 8.8 9.2 58 Perkiomen Valley South Elementary School 100 20 3.7 7.4 30 Pope John Paul II High School 100 20 9.4 12.9 44 Pottsgrove High School 100 20 8.7 4.1 127 Pottsgrove Middle School 100 20 9.7 4.3 136 Pottstown High School 100 20 9.9 3.0 198 Pottstown Middle School 100 20 10.4 3.1 202 Ringing Rocks Elementary 100 20 8.7 4.1 127 Royersford Elementary School 100 20 11.8 5.5 128 Rupert Elementary School 100 20 12.4 3.6 207 Sacred Heart School 100 20 10.1 5.2 116 Salford Hills Elementary 100 20 1.9 33.7 3
Schwenksville Elementary School 100 20 6.1 6.9 53 Skippack Elementary School 100 20 3.1 9.6 19 Skyview Upper Elementary School 100 20 0.0 0.0 0
Spring-Ford 5th-6th Grade Center 100 20 9.9 5.2 114 Spring-Ford 7th Grade Center 100 20 10.5 5.3 119 Spring-Ford 8th Grade Center 100 20 10.6 5.3 120 Spring-Ford Senior High School 10-12 Grade Center 100 20 10.1 5.2 116 Spring-Ford Senior High School 9th Grade Center 100 20 10.9 5.3 123 St. Aloysius 100 20 9.7 3.5 167 14.0 16.6 18.5 20.8 12.7 36.1 4.8 4.8 4.8 8.3 17.0 16.6 16.6 13.2 13.2 16.6 6.2 13.2 12.4 2.3 4.8 4.8 2.1 6.2 6.2 6.2 6.2 6.2 16.1 17 20 22 25 15 43 6
6 6
10 20 20 20 16 16 20 7
16 15 3
6 6
3 7
7 7
7 7
19 Limerick Generating Station Evacuation Time Estimate 8-55 KLD Engineering, P.C.
Rev. 0
St. Eleanor School 100 20 8.9 3.5 153 St. Gabriel's Hall 100 20 2.5 1.9 79 St. Mary's School 100 20 2.7 33.3 5
St. Peter's Lutheran Church - School 100 20 10.9 3.0 215 The Hill School 100 20 11.2 4.3 157 Upper Providence Elementary School 100 20 9.7 5.1 114 Ursinus College 100 20 3.1 1.5 125 Valley Forge Baptist Temple Academy 100 20 6.1 1.7 211 Wayside Christian School 100 20 5.5 2.6 128 West Pottsgrove Elementary School 100 20 14.0 5.0 167 Western Center for Technical Studies 100 20 10.5 27.1 23 Woodland Elementary 100 20 1.1 4.9 13 Wyndcroft School 100 20 10.3 3.0 1203 Almost Home Children's Center 100
_20 3.8 2.4 95 Boyertown Area YMCA 100 20 3.4 2.6 79 Douglassville Children's Center 100 20 2.1 5.9 21 Douglassville KinderCare 100 20 2.8 5.7 29 Gail Swartz Family Daycare 100 20 0.2 36.7 0
Saint Columbkill Preschool 100 20 2.8 2.2 77 St. Gabriel's Good Shepherd Learning Center 100 20 2.8 3.8 44 St. John's Lutheran Church 100 20 3.0 2.4 75 St. Paul's Day Care 100 20 4.1 5.8 42 Teresa Walter Family Daycare 100 20 1.0 4.9 12 Bright Light Early Learning Center 100 20 0.5 7.0 4
2.9 3
20.3 7.4 13.5 32.8 6.2 22.3 5.3 7.0 16.6 6.2 2.4 24 9
16 39 7
27 6
8 20 7
3
/.U 3.4 2.1 7.0 6.7 7.0 2.8 7.0 4.1 4
3 8
8 8
3 8
5 R
I.L I
Limerick Generating Station Evacuation Time Estimate 8-56 KLD Engineering, P.C.
Rev. 0
ren S Muse O iJortnern %nester L-ounfI 20 0.1+
East Coventry Elementary School i
100 20 13.4 14.7 55 iU.,
5.4 3.3 Grace Assembly Day Care Center 100 20 12.6 4.3 174 International Montessori 100 20 4.8 6.3 46 Kiddie Academy 100 20 5.4 9.0 36 Kids Kare Korner 100 20 12.2 4.2 173 Kindercare Learning Center No. 1405 100 20 9.6 5.5 105 Little Angels Day Care 100 20 5.0 6.3 48 Magic Memories 100 20 4.9 8.4 35 Our House Early Learning Center 100 20 12.8 8.8 88 Phoenixville Area Children Learning Center 100 20 4.6 6.3 44 Phoenixville Area Children's Learning Center 2 100 20 5.0 3.9 77 Phoenixville Area YMCA Child Care Center 100 20 4.6 7.3 38 Pottstown YMCA French Creek Elementary 100 20 6.0 8.8 41 Stepping Stone Education Center 100 20 5.0 3.9 77 Teach & Learn Day School 100 20 8.3 5.1 97 The Goddard School - Chester Springs 100 20 0.8 6.9 7
Valley Forge Kinder House Montessori School 100 20 3.9 12.0 19 Warwick Child Care - North Coventry Center 100 20 6.9 7.3 57 Warwick Child Care - South Coventry Center 100 20 6.5 8.9 44 Boyertown Children's Center 100 20 17.9 12.0 90 Bright Beginnings Child Care Center 100 20 10.2 7.7 79 Bright Spot Child Care 100 20 3.7 1.6 141 Chesterbrook Academy - Collegeville 100 20 1.4 1.7 48 Chesterbrook Academy - Limerick 100 20 13.5 4.8 168 Chesterbrook Academy - Norristown 100 20 2.9 4.5 38 Chesterbrook Academy - Phoenixville 100 20 6.9 3.5 117 Chesterbrook Academy - Royersford 100 20 11.4 4.4 155 12.2 12.2 3.3 3.3 12.2 12.2 5.4 12.2 12.2 12.2 4.2 12.2 3.3 7.2 12.2 5.4 A I la 6
4 15 15 4
4 15 15 6
15 15 15 5
15 4
9 15 6
q; b.Z 6.2 7.8 8.1 6.6 7.4 6.6 6.6 I
7 9
10 8
9 8
8 Limerick Generating Station Evacuation Time Estimate 8-57 KLD Engineering, P.C.
Rev. 0
I Children of America Trappe 100 20 7.7 4.0 115 Country Tyme Day Care 100 20 11.5 5.0 139 Coventry Christian Pre-School 100 20 11.2 7.3 92 Creative Beginnings Preschool 100 20 1.2 1.6 44 Creative Child Care Too 100 20 3.4 1.9 109 Creative Minds Montessori 100 20 19.3 10.3 113 Dotlen Academy 100 20 20.7 7.5 165 Flanagan's Pre-School 100 20 5.9 8.5 42 FV YMCA - Audubon Elementary 100 20 1.2 5.0 14 FV YMCA - Brooke Elementary School 100 20 11.4 4.4 155 FV YMCA - Evans Elementary School 100 20 9.4 7.3 77 FV YMCA - Limerick Elementary School 100 20 8.8 7.1 74 FV YMCA - Perkiomen Valley Middle School 100 20 6.2 5.7 65 FV YMCA - Pottstown Day Care 100 20 20.0 7.5 159 FV YMCA - Royersford Elementary School 100 20 11.8 8.1 88 FV YMCA - Spring Valley 100 20 9.3 7.3 77 FV YMCA - Woodland Elementary 100 20 1.1 5.0 13 Hendricks Family Growing Dreams 100 20 14.6 8.7 100 Jerusalem Lutheran Day Care Center 100 20 6.2 6.9 54 Kiddie Academy Collegeville 100 20 7.7 6.2 74 Kiddie Academy Royersford 100 20 13.1 4.8 163 Kids Kare Korner III 100 20 11.6 8.1 86 Kinder Works 100 20 10.2 7.7 79 Kindercare 3056 100 20 22.0 9.3 142 Kindercare 3060 100 20 9.0 3.8 144 Little Faces Learning Center 100 20 16.2 12.0 81 Little Footprints 100 20 23.9 7.2 200 Little Mary Daycare 100 20 20.7 7.5 165 Montgomery Early Learning Center 100 20 20.6 7.5 164 6.2 5.4 2.2 8.1 8.1 6.2 6.2 6.2 3.0 6.2 6.2 9.5 4.8 6.2 6.2 6.2 2.4 6.2 6.2 6.2 6.6 6.2 6.2 6.2 6.6 6.2 6.2 6.2 6.2 7
6 3
10 10 7
7 7
4 7
7 11 6
7 7
7 3
7 7
7 8
7 7
7 8
7 7
7 7
Limerick Generating Station Evacuation Time Estimate 8-58 KLD Engineering, P.C.
Rev. 0
rNew manover t-nll t-are I
I
/U o/
d.u
.I D.L
[
I r~ew hanover ~niia tare I
LU
'I
!AI D.L I
North Penn YMCA - Salford Hills Elementary i
100 20 1.9 34.1 North Penn YMCA - Schwenksville Elementary 100 20 6.1 6.9 53 Oaks Early Learning 100 20 5.3 3.4 93 Phoenixville Area YMCA - Eagleville Elementary 100 20 0.6 1.6 23 Phoenixville Area YMCA-Arrowhead Elementary 100 20 4.7 2.0 140 Phoenixville Area YMCA-Oaks Elementary School 100 20 4.6 3.3 83 Play and Learn - Collegeville 100 20 1.6 1.8 53 Play and Learn - Green Lane 100 20 3.2 37.0 5
Play and Learn - Royersford 100 20 10.0 3.9 153 Providence Christian Preschool 100 20 9.6 3.9 147 SEI Family Center 100 20 5.0 3.3 90 Short Stuff & Co 100 20 0.9 5.0 11 Spring Valley YMCA Child Care Facility 100 20 11.3 8.1 84 Sunny Dayz Child Care 100 20 20.7 7.5 165 The Goddard School - Gilbertsville 100 20 16.8 12.0 84 The Goddard School - Royersford 100 20 11.0 8.1 82 The Goddard School - Sanatoga 100 20 20.7 9.2 136 The Goddard School - Schwenksville 100 20 6.2 5.7 65 The Goddard School - Skippack 100 20 2.3 6.7 21 The Learning Experience 100 20 20.7 9.2 136 The Malvern School - Collegeville 100 20 3.4 1.9 109 The Malvern School - Royersford 100 20 13.0 4.8 162 The Malvern School of Oaks 100 20 6.0 3.4 105 Tot Spot Learning Center 100 20 4.3 1.9 134 Twin Acres Country Day School 100 20 7.8 4.9 96 Tykes and Tots Day Care 100 20 3.1 6.8 27 Valley Forge Children's Academy 100 20 1.8 4.8 23 Victory Early Learning Academy 100 20 1.5 4.9 18 2.3 4.8 6.6 3.1 2.4 12.7 15.8 23.9 6.6 6.6 6.6 7.0 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 8.1 6.6 6.6 8.1 4.4 6.2 8.2 8.7 3
6 8
4 3
15 19 29 8
8 8
8 7
7 7
7 7
7 7
7 10 8
8 10 5
7 10 10 Limerick Generating Station Evacuation Time Estimate 8-59 KLD Engineering, P.C.
Rev. 0
YMCA Growing Dreams Child Care Center Limerick Generating Station Evacuation Time Estimate 8-60 KLD Engineering, P.C.
Rev. 0
Table 8-9. School Evacuation Time Estimates - Snow Amity Elementary Center 11U Z!)
4.5 Z.U I
ib Boyertown Area High School 110 25 3.4 2.1 95 Boyertown Area Junior High School West 110 25 3.8 2.4 95 Boyertown Elementary School 110 25 3.8 2.4 95 Brookeside Montessori 110 25 2.2 3.6 37 Colebrookdale Elementary School 110 25 4.0 2.2 108 Daniel Boone Middle School 110 25 7.0 28.1 15 Jessie R. Wagner Adventist Elementary School 110 25 6.1 2.3 158 Monocacy Elementary Center 110 25 0.8 32.0 2
Pine Forge Elementary School 110 25 3.3 1.6 126 Barkley Elementary School 110 25 4.7 6.2 46 Center for Arts and Technology-Pickering Campus 110 25 4.9 10.2 29 Charlestown Elementary School 110 25 0.4 3.0 8
Collegeville Montessori Academy 110 25 15.4 5.6 165 East Coventry Elementary School 110 25 13.4 11.5 70 East Pikeland Elementary School 110 25 6.3 7.2 52 East Vincent Elementary School 110 25 10.4 9.7 64 French Creek Elementary School 110 25 6.0 6.6 55 Holy Family School 110 25 4.5 6.7 41 Kimberton-Waldorf School 110 25 7.4 9.6 46 Kindergarten Center 110 25 4.6 7.5 37 Montgomery School 110 25 2.2 31.6 4
North Coventry Elementary School 110 25 10.3 7.7 80 Owen J. Roberts High School 110 25 7.5 7.8 58 Owen J. Roberts Middle School 110 25 7.3 7.8 56 11..i 14.9 14.9 14.9 20.9 14.9 7.0 33.1 2.2 17.3 20 20 20 20 28 20 9
44 3
23 4.2 7.1 2.1 6.3 3.4 4.2 3.4 3.4 5.6 16.9 6.5 7.2 3.4 4.4 4.4 6
9 3
8 5
6 5
5 7
23 9
10 5
6 6
Limerick Generating Station Evacuation Time Estimate 8-61 KLD Engineering, P.C.
Rev. 0
Phoenixville Area High School 110 25 3.5 8.8 24 Phoenixville Area Middle School 110 25 3.6 8.8 24 Pickering Valley Elementary School 110 25 1.0 1.9 31 Renaissance Academy 110 25 5.3 10.3 31 Schuylkill Elementary School 110 25 2.5 9.9 15 Spring City Elementary School 110 25 12.1 5.9 124 St. Basil the Great School 110 25 7.3 8.8 50 Upattinas Open Community School 110 25 1.3 4.5 17 Nalley Forge Christian College 110 25 5.0 10.2 30 est Vincent Elementary School 110 25 7.7 34.6 13 est-Mont Christian Academy 110 25 11.3 3.6 189 rcola Intermediate School 110 25 2.8 3.3 51 rrowhead Elementary School 110 25 4.7 2.3 124 Audubon Elementary 110 25 1.2 7.8 9
Blessed Theresa of Calcutta 110 25 11.6 7.4 94 Boyertown Area Junior High School East 110 25 6.7 3.2 128 Bright Spot Kindergarten 110 25 3.7 1.6 139 Brooke Elementary School 110 25 11.4 3.5 197 Chapel Christian Academy 110 25 10.2 3.1 199 Coventry Christian Schools 110 25 11.2 10.4 65 Eagleville Elementary School 110 25 0.6 4.4 8
Edgewood Elementary School 110 25 9.7 3.3 178 Elizabeth B. Barth Elementary School 110 25 10.7 3.3 193 Evans Elementary School 110 25 9.4 2.6 214 Evergreen Elementary School 110 25 6.1 7.5 49 Franklin Elementary School 110 25 10.1 3.2 190 ilbertsville Elementary School 110 25 4.8 2.5 115 Limerick Elementary School 110 25 8.8 3.0 179 4.2 6
4.2 7.2 12.2 4.2 12.7 7.8 16.9 12.2 3.4 1n 1 6
10 16 6
17 10 23 16 5
1:Z zu. i L/
2.4 3.0 6.2 14.9 7.8 6.2 8.8 2.2 3.1 13.2 13.2 6.2 4.8 13.2 14.9 9.5 3
4 8
20 10 8
12 3
4 18 18 8
6 18 20 13 Limerick Generating Station Evacuation Time Estimate 8-62 KLD Engineering, P.C.
Rev. 0
Lincoln Elementary School 110 25 8.8 2.9 184 Lower Pottsgrove Elementary School 110 25 9.3 4.5 125 New Hanover-Upper Frederick Elementary School 110 25 5.9 3.0 117 New Life Youth & Family Services 110 25 1.2 17.8 4
Oaks Elementary School 110 25 4.6 4.1 67 Perkiomen Valley Academy 110 25 4.5 27.3 10 Perkiomen Valley High School 110 25 6.0 6.8 53 Perkiomen Valley Middle School - East 110 25 6.2 7.5 50 Perkiomen Valley Middle School -West 110 25 8.8 7.1 75 Perkiomen Valley South Elementary School 110 25 3.7 5.8 38 Pope John Paul II High School 110 25 9.4 15.5 36 Pottsgrove High School 110 25 8.7 4.1 126 Pottsgrove Middle School 110 25 9.7 4.2 138 Pottstown High School 110 25 9.9 3.2 187 Pottstown Middle School 110 25 10.4 3.4 185 Ringing Rocks Elementary 110 25 8.7 4.1 126 Royersford Elementary School 110 25 11.8 5.6 126 Rupert Elementary School 110 25 12.4 3.9 192 Sacred Heart School 110 25 10.1 5.2 117 Salford Hills Elementary 110 25 1.9 29.1 4
Schwenksville Elementary School 110 25 6.1 5.0 73 Skippack Elementary School 110 25 3.1 7.9 24 kyview Upper Elementary School 110 25 0.0 0.0 0
pring-Ford 5th-6th Grade Center 110 25 9.9 5.2 114 pring-Ford 7th Grade Center 110 25 10.5 5.3 118 pring-Ford 8th Grade Center 110 25 10.6 5.3 119 Spring-Ford Senior High School 10-12 Grade Center 110 25 10.1 5.2 117 Spring-Ford Senior High School 9th Grade Center 110 25 10.9 5.3 123 St. Aloysius 110 25 9.7 3.5 167 14.0 16.6 18.5 20.8 12.7 36.1 4.8 4.8 4.8 8.3 17.0 16.6 16.6 13.2 13.2 16.6 6.2 13.2 12.4 2.3 4.8 4.8 2.1 6.2 6.2 6.2 6.2 6.2 16.1 19 22 25 28 17 48 6
6 6
11 23 22 22 18 18 22 8
18 17 3
6 6
3 8
8 8
8 8
21 Limerick Generating Station Evacuation Time Estimate 8-63 KLD Engineering, P.C.
Rev. 0
St. Eleanor School 110 25 8.9 3.6 150 St. Gabriel's Hall 110 25 2.5 1.8 83 St. Mary's School 110 25 2.7 26.5 6
St. Peter's Lutheran Church - School 110 25 10.9 3.2 201 The Hill School 110 25 11.2 4.7 144 Upper Providence Elementary School 110 25 9.7 5.1 113 Ursinus College 110 25 3.1 1.8 104 Valley Forge Baptist Temple Academy 110 25 6.1 1.8 201 Wayside Christian School 110 25 5.5 2.6 129 West Pottsgrove Elementary School 110 25 14.0 5.3 158 Western Center for Technical Studies 110 25 10.5 33.4 19 Woodland Elementary 110 25 1.1 4.7 14 Vyndcroft School 110 25 10.3 3.4 183 Maxim~um for EPZ:
Average for EPZ lmost Home Children's Center 110 25 3.8 2.1 109 Boyertown Area YMCA 110 25 3.4 2.3 90 Douglassville Children's Center 110 25 2.1 5.1 25 Douglassville KinderCare 110 25 2.8 4.2 40 Gail Swartz Family Daycare 110 25 0.2 32.7 0
Saint Columbkill Preschool 110 25 2.8 2.0 84 St. Gabriel's Good Shepherd Learning Center 110 25 2.8 3.3 50
- t. John's Lutheran Church 110 25 3.0 2.2 82
- t. Paul's Day Care 110 25 4.1 4.9 50 eresa Walter Family Daycare 110 25 1.0 4.0 15 Bright Light Early Learning Center 110 25 0.5 4.5 7
2.9 20.3 7.4 13.5 32.8 6.2 22.3 S4F 27 10 18 44 8
30 7
5.3 7.0 16.6 6.2 2.4 17.8 9
22 8
3
/.U 3.4 2.1 7.0 6.7 7.0 2.8 7.0 4.1 5
3 9
9 9
4 9
5 q
I
.LU Limerick Generating Station Evacuation Time Estimate 8-64 KLD Engineering, P.C.
Rev. 0
Children's House of Northern Chester County 110 25 5.1 6.6 47 East Coventry Elementary School 110 25 13.4 11.5 70 Grace Assembly Day Care Center 110 25 12.6 6.7 112 International Montessori 110 25 4.8 5.9 49 Kiddie Academy 110 25 5.4 8.4 39 Kids Kare Korner 110 25 12.2 6.3 117 Kindercare Learning Center No. 1405 110 25 9.6 6.3 91 Little Angels Day Care 110 25 5.0 5.9 51 Magic Memories 110 25 4.9 7.0 42 Our House Early Learning Center 110 25 12.8 8.5 90 Phoenixville Area Children Learning Center 110 25 4.6 5.9 47 Phoenixville Area Children's Learning Center 2 110 25 5.0 3.8 79 Phoenixville Area YMCA Child Care Center 110 25 4.6 6.2 44 Pottstown YMCA French Creek Elementary 110 25 6.0 6.6 55 Stepping Stone Education Center 110 25 5.0 3.8 79 Teach & Learn Day School 110 25 8.3 6.1 82 The Goddard School - Chester Springs 110 25 0.8 4.5 11 Valley Forge Kinder House Montessori School 110 25 3.9 11.8 20 Warwick Child Care - North Coventry Center 110 25 6.9 7.7 54 harwick Child Care - South Coventry Center 110 25 6.5 7.1 55 Boyertown Children's Center 110 25 17.9 9.9 109 Bright Beginnings Child Care Center 110 25 10.2 7.0 88 Bright Spot Child Care 110 25 3.7 2.0 114 Chesterbrook Academy - Collegeville 110 25 1.4 2.1 40 Chesterbrook Academy - Limerick 110 25 13.5 4.6 176 Chesterbrook Academy - Norristown 110 25 2.9 4.8 36 Chesterbrook Academy - Phoenixville 110 25 6.9 3.3 125 Chesterbrook Academy - Royersford 110 25 11.4 4.3 161 10.9 5.4 3.3 12.2 12.2 3.3 3.3 12.2 12.2 5.4 12.2 12.2 12.2 4.2 12.2 3.3 7.2 12.2 5.4 A 9 15 7
4 16 16 4
4 16 16 7
16 16 16 6
16 4
10 16 7
6.2 7.8 I
58 10 8.1 6.6 7.4 6.6 6.6 11 9
10 9
9 Limerick Generating Station Evacuation Time Estimate 8-65 KLD Engineering, P.C.
Rev. 0
Children of America Trappe 110 25 7.7 3.9 117 Country Tyme Day Care 110 25 11.5 4.9 142 Coventry Christian Pre-School 110 25 11.2 6.5 104 Creative Beginnings Preschool 110 25 1.2 2.2 33 Creative Child Care Too 110 25 3.4 2.6 80 Creative Minds Montessori 110 25 19.3 9.4 124 Dotlen Academy 110 25 20.7 7.8 160 Flanagan's Pre-School 110 25 5.9 6.7 53 FV YMCA - Audubon Elementary 110 25 1.2 5.3 14 FV YMCA - Brooke Elementary School 110 25 11.4 4.3 161 FV YMCA - Evans Elementary School 110 25 9.4 7.0 81 FV YMCA - Limerick Elementary School 110 25 8.8 6.5 81 FV YMCA - Perkiomen Valley Middle School 110 25 6.2 4.9 75 FV YMCA - Pottstown Day Care 110 25 20.0 7.8 155 FV YMCA - Royersford Elementary School 110 25 11.8 7.8 90 FV YMCA - Spring Valley 110 25 9.3 7.0 80 FV YMCA - Woodland Elementary 110 25 1.1 5.3 13 Hendricks Family Growing Dreams 110 25 14.6 6.7 130 Jerusalem Lutheran Day Care Center 110 25 6.2 5.0 74 Kiddie Academy Collegeville 110 25 7.7 5.2 89 Kiddie Academy Royersford 110 25 13.1 4.5 174 Kids Kare Korner II1 110 25 11.6 7.8 89 Kinder Works 110 25 10.2 7.0 88 Kindercare 3056 110 25 22.0 8.5 154 Kindercare 3060 110 25 9.0 3.5 153 Little Faces Learning Center 110 25 16.2 9.3 104 Little Footprints 110 25 23.9 7.8 184 Little Mary Daycare 110 25 20.7 7.8 160 Montgomery Early Learning Center 110 25 20.6 7.8 159 6.2 5.4 2.2 8.1 8.1 6.2 6.2 6.2 3.0 6.2 6.2 9.5 4.8 6.2 6.2 6.2 2.4 6.2 6.2 6.2 6.6 6.2 6.2 6.2 6.6 6.2 6.2 6.2 6.2 8
7 31 11 8
88 8
83 8
8 8
8 13 8
8 8
9 8
8 8
8 8
8 8
8 Limerick Generating Station Evacuation Time Estimate 8-66 KLD Engineering, P.C.
Rev. 0
New Hanover Child Care 110 25 15.7 6.8 138 North Penn YMCA - Salford Hills Elementary 110 25 1.9 28.5 4
North Penn YMCA - Schwenksville Elementary 110 25 6.1 5.0 73 Oaks Early Learning 110 25 5.3 3.2 101 Phoenixville Area YMCA - Eagleville Elementary 110 25 0.6 2.2 17 Phoenixville Area YMCA-Arrowhead Elementary 110 25 4.7 2.6 107 Phoenixville Area YMCA-Oaks Elementary School 110 25 4.6 3.2 87 Play and Learn - Collegeville 110 25 1.6 2.1 47 Play and Learn - Green Lane 110 25 3.2 32.2 6
Play and Learn - Royersford 110 25 10.0 3.7 164 Providence Christian Preschool 110 25 9.6 3.7 158 SEI Family Center 110 25 5.0 3.2 94 Short Stuff & Co 110 25 0.9 5.3 10 Spring Valley YMCA Child Care Facility 110 25 11.3 7.8 86 Sunny Dayz Child Care 110 25 20.7 7.8 160 The Goddard School - Gilbertsville 110 25 16.8 9.9 102 The Goddard School - Royersford 110 25 11.0 7.5 89 The Goddard School - Sanatoga 110 25 20.7 8.2 152 The Goddard School - Schwenksville 110 25 6.2 4.9 75 The Goddard School - Skippack 110 25 2.3 4.9 28 The Learning Experience 110 25 20.7 8.2 152 The Malvern School - Collegeville 110 25 3.4 2.6 80 The Malvern School - Royersford 110 25 13.0 4.5 173 The Malvern School of Oaks 110 25 6.0 3.2 113 Tot Spot Learning Center 110 25 4.3 2.6 100 Twin Acres Country Day School 110 25 7.8 4.4 107 Tykes and Tots Day Care 110 25 3.1 5.5 34 Valley Forge Children's Academy 110 25 1.8 5.1 21
/ictory Early Learning Academy 110 25 1.5 5.1 18 6.2 2.3 4.8 6.6 3.1 2.4 12.7 15.8 23.9 6.6 6.6 6.6 7.0 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 8.1 6.6 6.6 8.1 4.4 6.2 8.2 8.7 8
3 6
9 4
3 17 21 32 9
9 9
9 8
8 8
8 8
8 8
8 11 9
9 11 6
8 11 12 Limerick Generating Station Evacuation Time Estimate 8-67 KLD Engineering, P.C.
Rev. 0
(MCA Growing Dreams Child Care Center Limerick Generating Station Evacuation Time Estimate 8-68 KLD Engineering, P.C.
Rev. 0
Table 8-10. Summary of Transit-Dependent Bus Routes Route~~~~~~
~ ~ ~
N.oBuePikUPins aogRueLnt m.
Schedule 1 2
S. Reading Ave & Walker Dr, S. Reading Ave & College, Walnut & W. Second St.
"Hub", and E. Philadelphia Ave at Chestnut Street - Inner Core Lot 3.6 Schedule 2 2
Second St & Madison St, Third St & Madison St, and Fourth St & Madison St 4.0 Schedule 3 2
N. Reading Ave & Spring St and Multi Service - YMCA Building 3.5 Schedule 4 2
W. Philadelphia Ave & Walnut St and W. Philadelphia Ave & Orchard Hills 2.9 Schedule 5 2
Borough Hall Lot, E. Philadelphia Ave & Franklin St, and E. Philadelphia Ave at 3.4 Chestnut St - Inner Core Lot Downtown 14 Municipal Parking Lot, Emergency Operation Center, Phoenix Cleaners Parking Lot, 5.6 Area and Presbyterian Church Parking Lot East Side 14 Second Avenue School, Reeves Park, Acme Parking Lot, and Barkley School 13.4 North Side 14 Black Rock Boat Dock, Friendship Field, High St. Playground, Holy Trinity Church, 10.1 Fairview St. Projects, and Westridge Community Ctr Phoenixville Area Sr. High, Walgreens, The West Company Parking Lot, Cascaden West Side 9
Park, DeSano Field, Werner Bus Company Lot, Grimm AME Church Field, Gaines 17.9 Creek Community Center, Eland Downes Community Center, Spring City Borough, St. Michaels Ukrainian Catholic Church, and United Methodist Church Central 14 St. Aloysius Church Social Hall, Second Baptist Church, 1st United Presbyterian 12.1 Zone Church, and First Church of the Brethren Chestmont Professional Building, Church of Nazarene, Pollock House, R. P. Smith East Zone 15 Towers, Richard Ricketts Community Center, Goodwill Fire Company, and 13.4 Congregation Mercy and Truth Synagogue North Zone 14 YMCA, and St. Paul's United Church of Christ 10.5 South Zone 14 Holy Trinity Roman Catholic Church 10.8 Limerick Generating Station Evacuation Time Estimate 8-69 KLD Engineering, P.C.
Rev. 0
Table 8-11. Transit-Dependent Evacuation Time Estimates - Good Weather Schedule 1 1 1-2 90 3.6 2.5 85 30 7.0 8
5 10 77 30 Schedule 2 1-2 90 4.0 2.2 107 30 Schedule 3 1-2 90 3.5 2.7 77 30 Schedule 4 1-2 90 2.9 2.9 59 30 Schedule 5 1-2 90 3.4 2.6 78 30 Downtown Area 1-7 90 5.6 5.3 63 30 Area Downtown 8-14 110 5.6 5.7 59 30 Area East Side 1-7 90 13.4 7.2 112 30 East Side 8-14 110 13.4 7.6 106 30 North Side 1-7 90 10.1 5.1 119 30 North Side 8-14 110 10.1 5.5 110 30 West Side 1-4 90 17.9 5.5 197 30 W
West Side 5-9 110 17.9 5.8 184 30 Central Central 1-7 90 12.1 3.3 220 30 Zonentr Central 8-14 110 12.1 3.4 214 30 Zone East Zone 1-7 90 13.4 3.7 217 30 East Zone 8-15 110 13.4 3.7 215 30 North 1-7 90 10.5 3.5 182 30 Zone 7.0 8
5 10 74 30 7.0 8
5 10 65 30 7.0 8
5 10 40 30 7.0 8
5 10 61 30 13.2 14 5
10 45 30 13.2 14 5
10 40 31 13.2 14 5
10 55 30 13.2 14 5
10 53 31 13.2 14 5
10 43 30 13.2 14 5
10 43 31 13.2 14 5
10 60 30 13.2 14 5
10 60 31 12.5 14 5
10 44 30 12.5 14 5
10 41 31 12.5 14 5
10 48 30 12.5 14 5
10 45 31 12.5 14 5
10 49 30 Limerick Generating Station Evacuation Time Estimate 8-70 KLD Engineering, P.C.
Rev. 0
Limerick Generating Station Evacuation Time Estimate 8-71 KLD Engineering, P.C.
Rev. 0
Table 8-12. Transit-Dependent Evacuation Time Estimates - Rain Limerick Generating Station Evacuation Time Estimate 8-72 KLD Engineering, P.C.
Rev. 0
North 8-14 Zone 120 10.5 3.4 185 1
40 12.5 15 5
10 52 40 South 1-7 100 10.8 3.0 218 40 Zone II
+
+
12.5 15 5
10 47 40
+
+
+
South Zone 8-14 120 10.8 3.3 200 40 12.5 15 5
10 47 40
.5 I. _______________ L Limerick Generating Station Evacuation Time Estimate 8-73 KLD Engineering, P.C.
Rev. 0
Table 8-13. Transit Dependent Evacuation Time Estimates - Snow bcneouie 1
.1-L IIU
- .b L.U lUts bU Schedule 2 1-2 110 4.0 1.9 126 50 Schedule 3 1-2 110 3.5 2.1 101 50 Schedule 4 1-2 110 2.9 2.1 81 50 Schedule 5 1-2 110 3.4 2.0 102 50 rDowntown Dontw 1-7 110 5.6 4.9 69 50 Area Dowtow 8-14 130 5.6 5.1 66 50 East Side 1-7 110 13.4 6.6 122 50 East Side 8-14 130 13.4 6.9 116 50 North Side 1-7 110 10.1 4.8 126 50 North Side 8-14 130 10.1 5.0 121 50 West Side 1-4 110 17.9 6.0 178 50 West Side 5-9 130 17.9 6.5 165 50 Central Ce 1-7 110 12.1 3.3 220 50 Zone Central 8-14 130 12.1 3.4 216 50 Zone East Zone 1-7 110 13.4 3.8 211 50 East Zone 8-15 130 13.4 3.9 207 50 Northh 1-7 110 10.5 3.4 185 50 Zone
/.U J
b 1U b4
- U 7.0 9
5 10 77 50 7.0 9
5 10 65 50 7.0 9
5 10 54 50 7.0 9
5 10 61 50 13.2 18 5
10 42 50 13.2 18 5
10 45 50 13.2 18 5
10 58 50 13.2 18 5
10 58 50 13.2 18 5
10 48 50 13.2 18 5
10 48 50 13.2 18 5
10 70 50 13.2 18 5
10 70 50 12.5 17 5
10 47 50 12.5 17 5
10 47 50 12.5 17 5
10 51 50 12.5 17 5
10 52 50 12.5 17 5
10 44 50 Limerick Generating Station Evacuation Time Estimate 8-74 KLD Engineering, P.C.
Rev. 0
North Zone 8-14 130 10.5 3.4 184 50 12.5 17 5
10 45 50 South 1 1-7 r 110 1 10.8 1 3.2 1 202 F 50 Zone I__
I_
12.5 j 17 5 J 10 1 46 ] 50 South Zone 8-14 130 10.8 3.4 194 50 12.5 17 5
10 44 50 Limerick Generating Station Evacuation Time Estimate 8-75 KLD Engineering, P.C.
Rev. 0
Table 8-14. Special Facility Evacuation Time Estimates - Good Weather Ambulatory VU 1
u I
.u b4 Chestnut Knoll Wheelchair bound 90 5
8 20 3.0 63 I
Bedridden 90 15 2
30 1
3.0 64 Ambulatory 90 1
20 20 1.7 2
Colonial Manor Adult Home Wheelchair bound 90 5
3 15 1.7 2
Bedridden 90 15 1
15 1.7 2
Ambulatory 90 1
90 30 3.0 55 Hearthstone at Amity Wheelchair bound 90 5
8 20 3.0 52 Bedridden 90 15 2
30 3.0 55 Ambulatory 90 1
100 30 3.3 52 Keystone Villa Wheelchair bound 90 5
11 20 3.3 48 Bedridden 90 15 3
30 3.3 52 Ambulatory 90 1
110 30 7.0 44 Atria Woodbridge at Wheelchair bound 90 5
8 20 7.0 45 Bedridden 90 15 2
30 7.0 44 Ambulatory 90 1
33 30 6.4 29 Coventry Manor Nursing Home Wheelchair bound 90 5
6 20 6.4 34 Bedridden 90 15 2
30 6.4 29 Ambulatory 90 1
20 20 11.9 57 Genesis Health Care at Spring Mill Wheelchair bound 90 5
2 10 11.9 58 Bedridden 90 15 0
0 11.9 60 Ambulatory 90 1
1225 30 4.1 21 Golden Living Centers - Phoenixville Wheelchair bound 90 5
4 20 4.1 1
23 Bedridden 90 15 1
15 4.1 24 Ambulatory 90 1
40 30 13.0 66 Manatawny Manor Wheelchair bound 90 5
64 20 13.0 74 Bedridden 90 15 16 30 13.0 66 Limerick Generating Station Evacuation Time Estimate 8-76 KLD Engineering, P.C.
Rev. 0
AmoulalorY 1
18 18 4.1 23 Phoenixville Convalescent Manor Wheelchair bound 90 5
40 20 4.1 23 Bedridden 90 15 10 30 4.1 21 Ambulatory 90 1
67 30 4.3 23 Phoenixville Hospital of the UPENN Health Wheelchair bound 90 5
48 20 4.3 25 System Bedridden 90 15 12 30 4.3 23 Ambulatory 90 1
165 30 13.8 145 Southeastern Pennsylvania Veterans Wheelchair bound 90 5
16 20 13.8 151 Bedridden 90 15 4
30 13.8 145 Ambulatory 90 1
222 30 4.8 129 Eagleville Hospital Wheelchair bound 90 5
40 20 4.8 133 Bedridden 90 15 10 30 4.8 129 4
Ambulatory 90 1
96 30 10.1 14 Frederick Mennonite Community Wheelchair bound 90 5
24 20 10.1 17 Bedridden 90 15 6
30 10.1 14 Ambulatory 90 1
103 30 9.7 129 HCR ManorCare Wheelchair bound 90 5
82 20 9.7 134 Bedridden 90 15 21 30 9.7 129 Ambulatory 90 1
75 30 11.9 113 Park Lane Commons Wheelchair bound 90 5
8 20 11.9 117 Bedridden 90 15 2
30 11.9 113 Ambulatory 90 1
400 30 8.5 95 Parkhouse, Providence Pointe Wheelchair bound 90 5
41 20 8.5 98 Bedridden 90 15 10 30 8.5 95 Ambulatory 90 1
115 30 10.4 114 Pottstown Memorial Medical Center Wheelchair bound 90 5
144 20 10.4 115 1
Bedridden 90 15 36 30 10.4 114 Limerick Generating Station Evacuation Time Estimate 8-77 KLD Engineering, P.C.
Rev. 0
Ambulatory 90 1
95 30 11.9 113 Sanatoga Center Wheelchair bound 90 1
5 19 1
20
[
11.9 117 I
Bedridden 90 15 5
30 11.9 4
+
4 4
113 3:55 80 3:20 Ambulatory 90 1
50 30 2.1 Shannondell at Valley Forge Wheelchair bound 90 5
8 20 2.1 79 3:10
.- ft-Bedridden 90 15 2
30 A
.4 __________________________
.1. ___________________
A -..-.--.-
~----
I. -
Limerick Generating Station Evacuation Time Estimate 8-78 KLD Engineering, P.C.
Rev. 0
Table 8-15. Medical Facility Evacuation Time Estimates - Rain AmDUiaiory Luu I
ju 5.u
+
I*
I*
8 20 3.0 73 Chestnut Knoll Wheelchair bound 100 5
8 20 3.0 73 Bedridden 100 15 2
30 3.0 67 Ambulatory 100 1
20 20 1.7 3
Colonial Manor Adult Home Wheelchair bound 100 5
3 15 1.7 3
Bedridden 100 15 1
15 1.7 3
Ambulatory 100 1
90 30 3.0 45 Hearthstone at Amity Wheelchair bound 100 5
8 20 3.0 48 Bedridden 100 15 2
30 3.0 45 Ambulatory 100 1
100 30 3.3 43 Keystone Villa Wheelchair bound 100 5
11 20 3.3 46 Bedridden 100 15 3
30 3.3 43 Ambulatory 100 1
110 30 7.0 52 Atria Woodbridge Place Wheelchair bound 100 5
8 20 7.0 54 Bedridden 100 15 2
30 7.0 52 Ambulatory 100 1
33 30 6.4 34 Coventry Manor Nursing Home Wheelchair bound 100 1
5 16 120 16.4 40 Bedridden 100 15 2
30 6.4 34 Ambulatory 100 1
20 20 11.9 69 3:10 Genesis Health Care at Spring Mill Wheelchair bound 1
100 5
1 2 1 10 1 11.91 71
_3:05 Bedridden 100 15 0
0 11.9 74 2:5 Ambulatory 100 1
125 30 4.1 21 2:35 Golden Living Centers - Phoenixville Wheelchair bound 100 5
4 20 4.1 23 2:25 Bedridden 100 15 1
15 4.1 25 2:20 Ambulatory 100 1
40 30 13.0 81 3:35 Manatawny Manor Wheelchair bound 100 5
64 20 13.0 89 3:30 Bedridden 100 15 16 30 13.0 81 3:35 Limerick Generating Station Evacuation Time Estimate 8-79 KLD Engineering, P.C.
Rev. 0
Ambulatory 100 1
18 18 4.1 23 Phoenixville Convalescent Manor Wheelchair bound 100 5
40 20 4.1 23 Bedridden 100 15 10 30 4.1 21 Amuaoy100 1
67 30 4.3 23 Phoenixville Hospital of the UPENN Health Ambulatory d
100 1
67 0
4.3 25 System Wheelchair bound 100 5
48 20 4.3 25 Bedridden 100 15 12 30 4.3 23 Ambulatory 100 1
165 30 13.8 165 Southeastern Pennsylvania Veterans Center Wheelchair bound 100 5
16 20 13.8 170 Bedridden 100 15 4
30 13.8 165 Ambulatory 100 1
222 30 4.8 120 Eagleville Hospital Wheelchair bound 100 5
40 20 4.8 122 Bedridden 100 15 10 30 4.8 120 Ambulatory 100 1
96 30 10.1 16 Frederick Mennonite Community Wheelchair bound 100 5
24 20 10.1 16 Bedridden 100 15 6
30 10.1 16 Ambulatory 100 1
103 30 9.7 146 HCR ManorCare Wheelchair bound 100 5
82 20 9.7 153 Bedridden 100 15 21 30 9.7 146 Ambulatory 100 1
75 30 11.9 114 Park Lane Commons Wheelchair bound 100 5
8 20 11.9 118 Bedridden 100 15 2
30 11.9 114 Ambulatory 100 1
400 30 8.5 114 Parkhouse, Providence Pointe Wheelchair bound 100 5
41 20 8.5 118 Bedridden 100 15 10 30 8.5 114 Ambulatory 100 1
115 30 10.4 117 Pottstown Memorial Medical Center Wheelchair bound 100 5
144 20 10.4 121 Bedridden 100 15 36 30 10.4 117 II Limerick Generating Station Evacuation Time Estimate 8-80 KLD Engineering, P.C.
Rev. 0
AmbUlatory IUU I
JU II.to I
114 Sanatoga Center Wheelchair bound 100 5
19 20 11.9 118 Rpdriddpn inn i5 5
30 11.9 114 Ambulatory 100 1
50 30 2.1 86 Shannondell at Valley Forge Wheelchair bound 100 5
8 20 2.1 84 Bedridden 100 15 2
30 2.1 86 Maximum E1E:
Avrg ETE:
Limerick Generating Station Evacuation Time Estimate 8-81 KLD Engineering, P.C.
Rev. 0
Table 8-16. Medical Facility Evacuation Time Estimates - Snow Ambulatory 110 1
90 30 3.0 79 Chestnut Knoll Wheelchair bound 110 5
8 20 3.0 81 Bedridden 110 15 2
30 3.0 79 Ambulatory 110 1
20 20 1.7 4
Colonial Manor Adult Home Wheelchair bound 110 5
3 15 1.7 3
Bedridden 110 15 1
15 1.7 3
Ambulatory 110 1
90 30 3.0 55 Hearthstone at Amity Wheelchair bound 110 5
8 20 3.0 57 Bedridden 110 15 2
30 3.0 55 Ambulatory 110 1
100 30 3.4 53 Keystone Villa Wheelchair bound 110 5
11 20 3.3 51 Bedridden 110 15 3
30 3.3 53 Ambulatory 110 1
110 30 7.0 50 Atria Woodbridge at Wheelchair bound 110 5
8 20 7.0 54 Bedridden 110 15 2
30 7.0 508 Ambulatory 110 1
33 30 6.4 25 Coventry Manor Nursing Home Wheelchair bound 110 5
6 20 6.4 51 Bedridden 110 15 2
30 6.4 50 Ambulatory 110 1
20 20 11.9 74 Genesis Health Care at Spring Mill Wheelchair bound 110 5
2 10 11.9 79 Bedridden 110 15 0
0 11.9 83 Ambulatory 110 1
125 30 4.1 25 Golden Living Centers - Phoenixville Wheelchair bound 110 5
4 20 4.1 26 Bedridden 110 15 1
15 4.1 26 Ambulatory 110 1
40 30 13.0 89 Manatawny Manor Wheelchair bound 110 1
5 64 20 13.0 94 Bedridden 110 1
15 16 30 113.0 89 Limerick Generating Station Evacuation Time Estimate 8-82 KLD Engineering, P.C.
Rev. 0
Amnoulatory Ilu 1
4.1 Zb
~mouiatorv li-u 4.1 lb I
4 4
4 4
4 Phoenixville Convalescent Manor Wheelchair bound 110 5
40 20 4.1 26 Wheelchair bound 110 5
40 20 4.1 26 4
.4 4
4 4
4 Bedridden 110 15 10 30 4.1 25 Ambulatory_____
110 T
1 67 30 4.3 27 Phoenixville Hospital of the UPENN Health Ambulatory 110 1
67 30 4.3_27 System Wheelchair bound 110 5
48 20 4.3 28 Bedridden 110 15 12 30 4.3 27 Ambulatory 110 1
165 30 13.8 117 Southeastern Pennsylvania Veterans Center Wheelchair bound 110 5
16 J 20 13.8 129 Bedridden 110 15 4
30 13.8 117 MOTOMR COUNTY Ambulatory 110 1
222 30 4.8 133 4:35 Eagleville Hospital Wheelchair bound 110 5
40 20 4.8 134 4:25 Bedridden 110 15 10 30 4.8 133 4:35 Ambulatory 110 1
96 30 10.1 20 2:40 Frederick Mennonite Community Wheelchair bound 110 5
24 20 10.1 18 2:30 Bedridden 110 15 6
30 10.1 20 2:40 Ambulatory 110 1
103 30 9.7 137 4:40 HCR ManorCare Wheelchair bound 110 5
82 20 9.7 141 4:35 Bedridden 110 15 21 30 9.7 137 4:40 Ambulatory 110 1
75 30 11.9 114 4:15 Park Lane Commons Wheelchair bound 110 5
8 20 11.9 117 4:10 Bedridden 110 15 2
30 11.9 114 4:15 Ambulatory 110 1
400 30 8.5 115 4:5 Parkhouse, Providence Pointe Wheelchair bound 110 5
41 20 8.5 118 4:10 Bedridden 110 15 10 30 8.5 115 4:15 Ambulatory 110 1
115 30 10.4 94 3:55 Pottstown Memorial Medical Center Wheelchair bound 110 5
144 20 10.4 98 3:5 Bedridden 110 15 36 30 10.4 94 3:55 Limerick Generating Station Evacuation Time Estimate 8-83 KLD Engineering, P.C.
Rev. 0
Ambulatory 110 I
1 95 30 11.9 114 Sanatoga Center Wheelchair bound 1
110
]
5
[
19 L 20 11.9 1
117 1
Bedridden 110 15 5
30 11.9 114 I
Ambulatory 110 1
I 50 30 2.1 90 I
Shannondell at Valley Forge Wheelchair bound 1 110 5
1 8
[20 1 2.1 1
89 Bedridden 110 15 I
2 30 2.1
.J. _____________________________
__j Limerick Generating Station Evacuation Time Estimate 8-84 KLD Engineering, P.C.
Rev. 0
Table 8-17. Homebound Special Needs Population Evacuation Time Estimates Wheelchair Vans 242 61 4
Good Rain Snow 90 100 110 5
27 30 33 15 24 24 24 Good 90 10 33 Ambulances 22 11 2
Rain 100 15 11 15 40 Snow 110 13 41 Maximum ETE:_
Average ElT:
2:SS 3:10 2:4S 3:05 3:15 Ij Limerick Generating Station Evacuation Time Estimate 8-85 KLD Engineering, P.C.
Rev. 0
9 TRAFFIC MANAGEMENT STRATEGY This section discusses the suggested traffic control and management strategy that is designed to expedite the movement of evacuating traffic. The resources required to implement this strategy include:
Personnel with the capabilities of performing the planned control functions of traffic guides (preferably, not necessarily, law enforcement officers).
Traffic Control Devices to assist these personnel in the performance of their tasks. These devices should comply with the guidance of the Manual of Uniform Traffic Control Devices (MUTCD) published by the Federal Highway Administration (FHWA) of the U.S.D.O.T. All state and most county transportation agencies have access to the MUTCD, which is available on-line: http://mutcd.fhwa.dot.gov which provides access to the official PDF version.
" A plan that defines all locations, provides necessary details and is documented in a format that is readily understood by those assigned to perform traffic control.
The functions to be performed in the field are:
- 1. Facilitate evacuating traffic movements that safely expedite travel out of the EPZ.
- 2. Discourage traffic movements that move evacuating vehicles in a direction which takes them significantly closer to the power plant, or which interferes with the efficient flow of other evacuees.
We employ the terms "facilitate" and "discourage" rather than "enforce" and "prohibit" to indicate the need for flexibility in performing the traffic control function. There are always legitimate reasons for a driver to prefer a direction other than that indicated. For example:
A driver may be traveling home from work or from another location, to join other family members prior to evacuating.
" An evacuating driver may be travelling to pick up a relative, or other evacuees.
The driver may be an emergency worker en route to perform an important activity.
The implementation of a plan must also be flexible enough for the application of sound judgment by the traffic guide.
The traffic management plan is the outcome of the following process:
- 1. The existing TCPs and ACPs identified by the offsite agencies in their existing emergency plans serve as the basis of the traffic management plan, as per NUREG/CR-7002.
- 2. Computer analysis of the evacuation traffic flow environment (see Figures 7-3 through 7-9).
This analysis identifies the best routing and those critical intersections that experience pronounced congestion. Any critical intersections that would benefit from traffic or access control which are not already identified in the existing offsite plans are suggested as additional TCPs and ACPs Limerick Generating Station 9-1 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 0
- 3. The existing TCPs and ACPs, and how they were applied in this study, are discussed in Appendix G.
Application of traffic and access control at some TCPs and ACPs will have a more pronounced influence on expediting traffic movements than at other TCPs and ACPs. For example, TCPs controlling traffic originating from areas in close proximity to the power plant could have a more beneficial effect on minimizing potential exposure to radioactivity than those TCPs located far from the power plant. These priorities should be assigned by state/local emergency management representatives and by law enforcement personnel.
The ETE simulations discussed in Section 7 indicate that the evacuation routes are oversaturated and experience pronounced traffic congestion during evacuation due to the limited capacity of the roadways and the large volume of evacuating traffic. US 422, Route 100, Route 562, Route 73, Route 23, Route 663, Route 363 and Route 29 are the most heavily used evacuation routes. The ramps to the interstates are significant bottlenecks. The traffic signals along the state routes are also significant bottlenecks. Nearly all of the traffic signals in the EPZ are actuated traffic signals and will adjust their timing to changing traffic patterns. Traffic control at signalized intersections will not have a pronounced impact on the evacuation process as most of the intersections have significant volume on the east-west approaches as well as the north-south approaches (see Figure 7-4 for several examples - intersection of Route 100 and High Street in Pottstown; intersection of Township Line Road and Ridge Parkway in Limerick; etc.) Thus, no additional TCPs or ACPs are deemed necessary as a result of this study.
The use of Intelligent Transportation Systems (ITS) technologies can reduce manpower and equipment needs, while still facilitating the evacuation process. Dynamic Message Signs (DMS) can be placed within the EPZ to provide information to travelers regarding traffic conditions, route selection, and reception center information. DMS can also be placed outside of the EPZ to warn motorists to avoid using routes that may conflict with the flow of evacuees away from the power plant. Highway Advisory Radio (HAR) can be used to broadcast information to evacuees en route through their vehicle stereo systems. Automated Traveler Information Systems (ATIS) can also be used to provide evacuees with information. Internet websites can provide traffic and evacuation route information before the evacuee begins their trip, while on board navigation systems (GPS units), cell phones, and pagers can be used to provide information en route. These are only several examples of how ITS technologies can benefit the evacuation process. Consideration should be given that ITS technologies be used to facilitate the evacuation process, and any additional signage placed should consider evacuation needs.
The ETE analysis treated all controlled intersections that are existing ACP or TCP locations in the offsite agency plans as being controlled by actuated signals.
Chapters 2N and 5G, and Part 6 of the 2009 MUTCD are particularly relevant and should be reviewed during emergency response training.
The ETE calculations reflect the assumption that all "external-external" trips are interdicted and diverted after 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> have elapsed from the ATE.
Limerick Generating Station 9-2 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 0
All transit vehicles and other responders entering the EPZ to support the evacuation are assumed to be unhindered by personnel manning ACPs and TCPs.
Study Assumptions 5 and 6 in Section 2.3 discuss ACP and TCP staffing schedules and operations.
Limerick Generating Station Evacuation Time Estimate 9-3 KLD Engineering, P.C.
Rev. 0