February 25, 2014

SUBJECT:

OREGON STATE UNIVERSITY - NRC ROUTINE INSPECTION REPORT NO.

50-243/2014-201

Dear Dr. Reese:

From January 27-30, 2014, the U.S. Nuclear Regulatory Commission (NRC or the Commission)

conducted an inspection at the Oregon State University Radiation Center TRIGA Mark-II Reactor facility (Inspection Report No. 50-243/2014-201). The enclosed report documents the inspection results, which were discussed on January 30, 2014, with Mr. Todd Keller, Reactor Administrator, and other members of your staff, as well as Dr. Andrew Klein, Chair of the Reactor Operations Committee.

The inspection examined activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license.

The inspector reviewed selected procedures and records, observed activities, and interviewed personnel. Based on the results of this inspection, no findings of significance were identified.

No response to this letter is required.

In accordance with Title 10 of the Code of Federal Regulations, Section 2.390, Public inspections, exemptions, and requests for withholding, a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRC Public Document Room or from the NRCs document system (Agencywide Documents Access and Management System (ADAMS)). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). Should you have any questions concerning this inspection, please contact Craig Bassett at (301) 466-4495 or by electronic mail at Craig.Bassett@nrc.gov.

Sincerely,

/RA/

Gregory T. Bowman, Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation

Docket No.: 50-243 License No.: R-106

Enclosure:

NRC Inspection Report No. 50-243/2014-201

cc w/encl.: Please see next page

Oregon State University

Docket No. 50-243

cc:

Mayor of the City of Corvallis Corvallis, OR 97331

David Stewart-Smith Oregon Office of Energy 625 Marion Street, N.E.

Salem, OR 97310

Dr. Richard Spinrad, Vice President for Research Oregon State University Administrative Services Bldg., Room A-312 Corvallis, OR 97331-5904

Mr. Todd Keller Reactor Administrator Oregon State University Radiation Center, A-100 Corvallis, OR 97331-5903

Dr. Andrew Klein, Chairman Reactor Operations Committee Oregon State University Radiation Center, A-100 Corvallis, OR 97331-5904

Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611

ML14036A142 *concurred via e-mail NRC-002 OFFICE NRR/DPR/PROB*

NRR/DPR/PROB NAME CBassett GBowman DATE 2/6/2014 2/25/2014

U. S. NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION

Docket No:

50-243

License No:

R-106

Report No:

50-243/2014-201

Licensee:

Oregon State University

Facility:

TRIGA Mark-II Reactor Facility

Location:

Radiation Center Oregon State University Corvallis, Oregon

Dates:

January 27-30, 2014

Inspector:

Craig Bassett

Accompanied by:

Doug Simpkins, Instructor, NRC Technical Training Center

Approved by:

Gregory T. Bowman, Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation

EXECUTIVE SUMMARY

Oregon State University TRIGA Mark-II Reactor Facility Report No: 50-243/2014-201

The primary focus of this routine, announced inspection was the onsite review of selected aspects of the Oregon State University (the licensees) 1.1 Megawatt Class II research reactor safety program, including: (1) organization and staffing, (2) review and audit and design change functions, (3) reactor operations, (4) operator requalification, (5) procedures, (6) fuel movement, (7) maintenance and surveillance, (8) experiments, and (9) emergency preparedness since the last U.S. Nuclear Regulatory Commission (NRC) inspection of these areas. The licensees program was acceptably directed toward the protection of public health and safety and in compliance with NRC requirements.

Organization and Staffing

  • The licensees organization and staffing were in compliance with the requirements specified in Technical Specification (TS) Section 6.

Review and Audit Functions and Design Change Control

  • Review, audit, and oversight functions required by TS Section 6.2 were acceptably completed by the Reactor Operations Committee.
  • Modifications or changes to the facility procedures; experiments; and structures, systems, and components had undergone the required screenings and evaluations and had been reviewed and approved by the Reactor Operations Committee.

Reactor Operations

  • Reactor operations were conducted and documented in accordance with TS and applicable procedural requirements and guidance.

Operator Licenses, Requalification, and Medical Activities

  • Operator requalification was conducted as required and the program was up-to-date and being acceptably implemented.
  • Medical examinations were being completed biennially for each operator as required.

Procedures

  • Facility procedures were acceptable and procedure revisions were reviewed and approved in accordance with TS Section 6.4.
  • Procedural compliance was observed and found to be acceptable.

- 2 -

Fuel Movement

  • Fuel handling activities were conducted in accordance with facility procedures and fuel inspections were completed and documented as required by TS Sections 4.1.e and 5.3.

Maintenance and Surveillance

  • Maintenance was being completed in accordance with TS and procedural requirements.
  • The program for surveillance verifications and calibrations was being implemented in accordance with TS requirements.

Experiments

  • The program for conducting and controlling experiments satisfied regulatory and requirements specified in TS Sections 3.8 and 4.8.

Emergency Preparedness

  • Emergency response facilities and equipment were being maintained as required and responders were knowledgeable of proper actions to take in case of an emergency.
  • The licensee maintained current emergency support agreements with offsite agencies to ensure that support would be available in case of an emergency.
  • Annual drills were being held and documentation was maintained concerning the follow-up critiques and any needed corrective actions.

REPORT DETAILS

Summary of Plant Status

Oregon State University (the licensee) continued to operate the 1.1 megawatt TRIGA Mark-II research reactor in support of laboratory demonstrations, reactor surveillances, and sample irradiations. Observation of reactor operation and a review of applicable records indicated that the reactor was typically operated approximately 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> per day, 5 days per week. During this inspection, the reactor was started up and operated several hours per day at varying power levels for sample irradiation and engineering class laboratories.

1.

Organizational Structure and Staffing

a.

Inspection Scope (Inspection Procedure (IP) 69001)

The inspector reviewed the following regarding the licensees organization and staffing to ensure that the requirements of Section 6 of the Technical Specifications (TS), revised through Amendment No. 22 of the facility operating license, dated September 30, 2008, were being met:

  • Oregon State University (OSU) Radiation Center and Oregon State TRIGA Reactor (OSTR) facility organizational structure and staffing

Selected portions of the Reactor Console Logbooks for the past 2 years, which indicated staffing levels during routine reactor operations

Oregon State University TRIGA Reactor Operating Procedure (OSTROP) 6, Administrative and Personnel Procedures, Rev. LEU-2, reprinted August 2012, which outlined various administrative controls

OSU Radiation Center and TRIGA Reactor Annual Report for the period of July 1, 2011, through June 30, 2012, submitted to the NRC on October 26, 2012

OSU Radiation Center and TRIGA Reactor Annual Report for the period from July 1, 2012, through June 30, 2013, submitted to the NRC on October 29, 2013

American National Standards Institute/American Nuclear Society (ANSI/ANS) 15.4-1988; R1999, Selection and Training of Personnel for Research Reactors, dated 1999

b.

Observations and Findings

The inspector noted that the Director of the Radiation Center continued to report to the President of the University through the Vice President for Research. It was also noted that the Radiation Center organizational structure and the responsibilities of the reactor staff were as outlined in TS Section 6 and OSTROP 6 and had not changed since the last inspection.

Staffing levels remained consistent with those noted during the last inspection of this facility. The current reactor operations organization consisted of the Director of the Radiation Center, the Reactor Administrator, the Reactor Supervisor, a

- 2 -

Reactor Engineer, and a Development Engineer. It was noted that these four individuals were qualified senior reactor operators (SROs). The staff also included one other full-time SRO (a faculty member) and five part-time reactor operators (ROs), who were students. This organization was as required and was consistent with that specified in the TS.

The inspector reviewed the qualifications of the reactor staff. All personnel satisfied the training and experience requirements stated in ANSI/ANS 15.4, Standard for the Selection and Training of Personnel for Research Reactors, as stipulated in the TS. A review of the Reactor Console Logbooks and associated records confirmed that shift staffing met the minimum requirements for duty and on-call personnel.

c.

Conclusion

Organizational structure and staffing were in compliance with the requirements specified in TS Section 6.

2.

Review and Audit, and Design Change Functions

a.

Inspection Scope (IP 69001)

In order to verify that the licensee had established and conducted reviews and audits as required by TS Section 6.2 and to determine whether modifications to the facility had been reviewed in accordance with Title 10 of the Code of Federal Regulations (10 CFR) Section 50.59, the inspector reviewed:

  • OSU 50.59 Screen Logbook

OSU 50.59 Evaluation Logbook

Design change functions outlined in OSTROP 6

Reactor Operations Committee (ROC) meeting minutes from February 2012 to the present

ROC Quarterly and Annual Audit and review records for the past 2 years

Change screen reviews conducted under and documented in accordance with OSTROP 6, Figure 6.1 entitled, Oregon State TRIGA Reactor (OSTR) 10 CFR 50.59 Screen Form, Nos. 12-01 through 12-05, 13-01 through 13-11, and 14-01 through 14-02

Change evaluations conducted under and documented in accordance with OSTROP 6, Figure 6.2 entitled, OSU TRIGA Reactor (OSTR)

10 CFR 50.59 Evaluation Form, No. 12-01 and 13-01

OSTROP 6, Administrative and Personnel Procedures, Rev. LEU-2

OSU Radiation Center and TRIGA Reactor Annual Report for the period of July 1, 2011, through June 30, 2012, submitted to the NRC on October 26, 2012

OSU Radiation Center and TRIGA Reactor Annual Report for the period from July 1, 2012, through June 30, 2013, submitted to the NRC on October 29, 2013

- 3 -

b.

Observations and Findings

(1)

Review and Audit Functions

The inspector reviewed the ROC meeting minutes from February 2012 to the present. These meeting minutes showed that the committee met quarterly and had considered the types of topics outlined by the TS Section 6.2. Review of the committee meeting minutes also indicated that the ROC provided appropriate guidance and direction for reactor operations, and ensured suitable use and oversight of the reactor.

It was noted that ROC members completed quarterly audits of reactor operations and related records, as well as annual reviews of the reactor operator requalification, emergency preparedness, and security programs. The inspector noted that the audits and the resulting findings were acceptable and the audits were generally completed within the time frame stipulated by the TS.

(2)

Design Control

The inspector reviewed recent 10 CFR 50.59 screen and evaluation forms and interviewed licensee personnel concerning proposed changes to facility procedures; tests; experiments; and/or structures, systems, and components (SSCs). The inspector determined that screenings had been conducted as required. Some of these screenings mandated the completion of evaluations in accordance with the requirements of OSTROP 6. The screenings and evaluations had been documented as required, had been reviewed and approved by the ROC as needed, and had been signed off by the appropriate personnel. None of the evaluations were found to require a license amendment.

c.

Conclusion

Review, audit, and oversight functions required by TS Section 6.2 were acceptably completed by the ROC. Modifications or changes to the facility procedures, experiments, and SSCs had undergone the required screenings and evaluations and had been reviewed and approved by the ROC.

3.

Operations

a.

Inspection Scope (IP 69001)

To verify that the licensee was operating the reactor in accordance with TS Sections 2 and 3 and the applicable procedures, the inspector reviewed selected portions and/or aspects of:

  • Staffing during routine reactor operations

Licensed Operator Time Log Sheets for the past 2 years

Selected portions of the Reactor Supervisors Log, Volume 15

- 4 -

Selected OSU TRIGA Reactor Daily Power Log Sheets for the past 6 months

Reactor operations documented in various Reactor Console Logbooks, Nos. 156-161

Observation of startup, operations, and/or shutdown activities on January 28, 29, and 30, 2014

Start-up activities documented on selected OSTROP 2 forms entitled OSU TRIGA Reactor Startup Checklist, from January through December 2013

Shut down activities documented on selected OSTROP 3 forms entitled Reactor Shutdown Checklists, from January through December 2013

Selected records of console instrumentation readings documented on OSU TRIGA Reactor Daily Power Log Sheets for the past year

Various OSTROP procedures including No. 2, 3, 4, 5, 25, and 27

OSU Radiation Center and TRIGA Reactor Annual Report for the period of July 1, 2011, through June 30, 2012, submitted to the NRC on October 26, 2012

OSU Radiation Center and TRIGA Reactor Annual Report for the period from July 1, 2012, through June 30, 2013, submitted to the NRC on October 29, 2013

b.

Observations and Findings

The inspector conducted observations of the reactor staff on January 28, 29, and 30, and reviewed Reactor Console Logbooks and associated records. The inspector noted that the licensed reactor operators were knowledgeable and competent. Observation of operational activities also confirmed that reactor operations, including start-ups, routine operations, and shutdowns, were carried out in accordance with written procedures and TS requirements. Adherence to procedures was acceptable.

Through these direct observations and document reviews, the inspector also confirmed that shift staffing during reactor operation met the TS requirements for duty and on-call personnel. The inspector noted that the logs were being maintained as required by procedure and the records and associated forms provided an acceptable indication of operational activities. The logs indicated that the recorded operational conditions were within the limits specified in the license and TS. The Reactor Console Logbooks, as well as other associated records, also documented abnormal events that occurred and measures that had been taken to track and resolve the events. These logbooks also documented removal and replacement of the annular reflector during 2013.

c.

Conclusion

Reactor operations were completed and documented in accordance with TS and procedural requirements.

- 5 -

4.

Operator Licenses, Requalification, and Medical Activities

a.

Inspection Scope (IP 69001)

The inspector reviewed the following in order to determine that operator training and requalification activities were conducted as required by the requalification program and that medical requirements were met:

  • Effective dates of current operator licenses

Reactor operators medical examination records for the past 3 years

Operator training records documented in the Operator Requalification Manual

TRIGA Reactor Operator Requalification Exam Results forms for 2011, 2012, and 2013

Reactor operations documented in various Reactor Console Logbooks, Nos. 156-161

Requalification Program for Licensed Operators of the Oregon State TRIGA Reactor, Rev. 1, reprinted September 30, 2004

Logs and records of the number of hours spent operating the reactor maintained in the Operator Time Log and associated manual

Active duty status and OSTR Annual Requalification Operating Test results documented in the Operator Time Log and associated manual

OSTROP 16, Annual Surveillance and Maintenance Procedures, and related log sheets

b.

Observations and Findings

At the time of the inspection, there were six qualified SROs and five ROs working at the facility. The inspector verified that all the operators licenses were current.

A review of the logs and records showed that training had been conducted in the areas stipulated in the licensees requalification and training program, such that all the material was covered within a 2 year period. It was noted that lectures had been given as stipulated, training reviews had been documented, and written examinations had been completed. An annual operating test had been conducted for each operator by the Reactor Supervisor as required by the program as well. It was also verified that each operator had completed the required number of hours of reactor operations each calendar quarter, as required. Records of these reactor manipulations, other operational activities, and/or Reactor Supervisor activities were being maintained, as were records of the annual operating tests. The program was up-to-date and training was current. The inspector noted that appropriate remedial actions were taken in the event of exam failures.

In addition to the above, the inspector verified that medical examinations were being completed biennially for each operator as required, and that medical conditions that could impact an operators ability to comply with license conditions were appropriately addressed by the licensee.

- 6 -

c.

Conclusion

The requalification and training program was up-to-date and acceptably implemented and maintained.

5.

Procedures

a.

Inspection Scope (IP 69001)

To determine whether facility procedures were being audited annually and whether the procedures met the requirements outlined in TS Section 6.4, the inspector reviewed:

  • Selected operating procedures, including OSTROPs 1, 2, 4, 5, 6, 8, 9, and 30

Procedural reviews and updates documented in ROC meeting minutes.

  • Change screen reviews conducted under and documented in accordance with OSTROP 6, Figure 6.1 entitled, Oregon State TRIGA Reactor (OSTR) 10 CFR 50.59 Screen Form, Nos. 12-01 through 12-05, 13-01 through 13-11, and 14-01 through 14-02

Change evaluations conducted under and documented in accordance with OSTROP 6, Figure 6.2 entitled, OSU TRIGA Reactor (OSTR)

10 CFR 50.59 Evaluation Form, No. 12-01 and 13-01

b.

Observations and Findings

The licensees procedures were found to be acceptable for the facilitys current operating status and staffing level. It was noted that the procedures specified the responsibilities of the various members of the staff. The inspector determined that the procedures were being audited and reviewed annually by the ROC as required and revised as needed.

Changes to procedures were screened according to OSTROP 6. If the changes did not result in a change to the intent of the procedure, they were routed to all licensed SROs, the Senior Health Physicist, the Reactor Administrator, and the Director, who signed and dated the change indicating review and concurrence.

Substantive changes to procedures, checklists, and forms were required to undergo a 10 CFR 50.59 evaluation. They were then presented to the ROC for review and approval as required by TS.

The activities and operations observed by the inspector during this inspection were completed in accordance with the applicable procedures. These activities and operations included reactor startup and shut down, equipment checkouts, reactor operation, insertion of a sample into the thermal column, and removal and handling of Antimony samples.

- 7 -

c.

Conclusion

Facility procedures were being reviewed and audited annually as required by TS Section 6 and procedure revisions were reviewed and approved by the ROC.

Procedural compliance was acceptable.

6.

Maintenance and Surveillance

a.

Inspection Scope (IP 69001)

To determine that surveillance requirements and limiting conditions for operation (LCO) verifications were being completed as required by TS Sections 3 and 4, and that maintenance activities were conducted when required, the inspector reviewed:

  • Selected portions of the Reactor Supervisors Log, Volume 15

Reactor operations documented in various Reactor Console Logbooks, Nos. 156-161

Selected surveillance and calibration test data sheets and records maintained in the Surveillance and Maintenance Records Notebook

Selected OSTROP procedures including Nos. 8, 9, 12, 13, 14, 15, 16, and 19

OSU Radiation Center and TRIGA Reactor Annual Report for the period of July 1, 2011, through June 30, 2012, submitted to the NRC on October 26, 2012

OSU Radiation Center and TRIGA Reactor Annual Report for the period from July 1, 2012, through June 30, 2013, submitted to the NRC on October 29, 2013

b.

Observations and Findings

The Reactor Supervisor maintained a schedule for reactor operations and tracked the completion of maintenance and surveillance activities. The inspector noted that selected daily, monthly, quarterly, semiannual, and annual checks, tests, verifications, and/or calibrations for TS-required surveillances and LCO verifications were being completed as stipulated. The surveillances and LCO verifications reviewed were generally completed on schedule and in accordance with licensee procedures. It was noted that some items had to be delayed due to the reflector replacement project. However, following the replacement project, all items that had been delayed were completed prior to resuming routine operations. All the recorded results that were reviewed were within the TS and procedurally prescribed parameters. The records and logs reviewed were complete and being maintained as required.

The maintenance logs and records indicated that problems were addressed and preventive maintenance operations completed as required. Records showed that routine maintenance activities were conducted at the required frequencies and in accordance with the TS and/or the applicable procedure. Maintenance activities

- 8 -

ensured that equipment remained consistent with the Safety Analysis Report and TS requirements.

c.

Conclusion

The program for surveillance and LCO confirmations was being carried out in accordance with TS and procedural requirements. Maintenance was also being completed as required.

7.

Fuel Movement

a.

Inspection Scope (IP 69001)

The inspector reviewed the following to verify adherence to fuel handling, positioning, and inspection requirements specified in TS Sections 4.1.e and 5.3:

  • Fuel handling equipment and instrumentation

Selected portions of the Reactor Supervisors Log, Volume 15

Reactor operations documented in various Reactor Console Logbooks, Nos. 156-161

Fuel handling and examination records for the past 2 years, documented on Oregon State University TRIGA Mark II Research Reactor Fuel Element History File cards maintained in the Fuel Element History Logbook and on Fuel Element Transfer Index Sheet forms maintained in a separate notebook

Selected OSTROP procedures, including Nos. 11, 16, 20, and 30

b.

Observations and Findings

The inspector noted that the licensee was operating with Low Enriched Uranium Core No.1. It was also noted that the reactor could be operated in different configurations depending upon what equipment was installed in the B-1 or G-14 position of the core. The actual configuration was noted in the Reactor Console Logbook. Through a review of related logs and records, the inspector noted that the core configuration, control rods, and fuel were as stipulated in the TS.

The inspector determined that the licensee was maintaining the required records of the various fuel movements that were completed and verified that the movements were conducted in accordance with procedure. The procedures used for fuel movement and inspection were acceptable, as were the precautions that were required to be established during such evolutions. Fuel element locations were being tracked by annotations to the applicable fuel element history file cards and on a fuel status board maintained in the reactor control room.

The inspector noted that twenty percent of the elements were inspected each year, such that the entire core was inspected over a 5 year period. The elements were visually inspected to check for damage and deterioration and measured to check for concentricity or other swelling. The results of these inspections were

- 9 -

being documented in the Reactor Console Logbook and on the applicable fuel element history forms as required. The latest fuel inspection was completed on December 18, 2013.

c.

Conclusion

Reactor fuel movements were made and documented in accordance with procedure. The fuel was being inspected as stipulated by TS Section 4.1.e and 5.3.

8.

Experiments

a.

Inspection Scope (IP 69001)

The inspector reviewed the following to verify that experiments were being conducted within approved guidelines specified in TS Sections 3.8 and 4.8:

  • Irradiation Request (IR) Index No. 3

Selected OSU approved experiments

Potential hazards identification and control of irradiated items

Documentation of experiment review and approval by the ROC

General Limitations of Experiments Performed Using the OSU TRIGA Reactor

Selected OSU TRIGA Reactor Irradiation Request Information Sheet forms for the past 2 years

Reactor operations documented in various Reactor Console Logbooks, Nos. 156-161

Selected Irradiation Request Pneumatic Transfer Sample Information Forms for the past year

OSU Radiation Center and TRIGA Reactor Annual Report for the period of July 1, 2011, through June 30, 2012, submitted to the NRC on October 26, 2012

OSU Radiation Center and TRIGA Reactor Annual Report for the period from July 1, 2012, through June 30, 2013, submitted to the NRC on October 29, 2013

b.

Observations and Findings

The licensee had three types of experiments at the facility, based generally on the reactivity, amount of shielding required, and the amounts of radioisotopes produced. The inspector verified that all the active experiments had been reviewed and approved by the ROC as required. The inspector noted that there have been no changes since the previous inspection period.

A review of the records maintained by the licensee indicated that all experiments were completed under the cognizance of the Reactor Supervisor as required.

The results of the experiments were documented appropriately. IR forms, required for reactor use, were also reviewed. The IR forms were being

- 10 -

completed as required. The forms documented the individual users, the required approvals and licenses, the length of the irradiations, the expected resulting radionuclides that would be produced, and the ultimate disposition of the material following the irradiations.

c.

Conclusion

The licenses program for the control of experiments satisfied regulatory and TS requirements.

9.

Emergency Preparedness

a.

Inspection Scope (IP 69001)

To verify proper implementation of the licensees Emergency Preparedness Program, the inspector reviewed selected aspects of:

  • Training and emergency drill records for the past 2 years

Offsite support as documented in emergency support agreements

Emergency response facilities, supplies, equipment, and instrumentation

Oregon State University Radiation Center and Oregon State TRIGA Reactor (OSTR) Emergency Response Plan, Rev. 5, latest revision dated December 2010

Oregon State University Radiation Center and Oregon State TRIGA Reactor (OSTR) Emergency Response Implementing Procedures (ERIP), Nos. 0-9, latest revision dated December 2011

OSTROP 1, Emergency Operating Procedures, Rev. LEU-2, reprinted August 2012

b.

Observations and Findings

The Emergency Plan (E-Plan) in use at the facility was the same as the version approved by the NRC and was last revised December 2010. The E-Plan was audited and reviewed annually by the ROC as required. Implementing procedures were also reviewed annually and revised by the licensee as needed to effectively implement the E-Plan. It was also noted that emergency response equipment at the facility was being maintained and inventoried at the frequencies required in the E-Plan. Communications capabilities were acceptable and were tested periodically.

Through records review and interviews with licensee personnel, emergency responders were determined to be knowledgeable of the proper actions to take in case of an emergency. Emergency response facilities and equipment were being maintained as required. An emergency support agreement with the Good Samaritan Hospital in Corvallis had been updated and maintained as necessary.

Agreements were also being maintained with the City of Corvallis Fire and Police Departments as required. Various crews and/or personnel from these off-site

- 11 -

support organizations visited the facility periodically and were familiar with the facility and what would be required during a response.

Emergency preparedness and response training for staff and specific support group personnel was being completed annually as required. The licensee continued to conduct drills annually as stipulated in the E-Plan in order to test communications procedures and ensure proper response of facility personnel to simulated radiological, industrial, or security problems. The inspector verified that every 2 years the drills were structured to involve, and require the participation of, off-site support agencies and personnel. Critiques were conducted following the drills to discuss and identify any strengths or weaknesses noted. Evacuation drills had been conducted each year as well.

The inspector visited the Corvallis Fire Department (CFD) and observed the equipment maintained by the CFD for response to an emergency at the facility.

From this visit, and as a result of reviewing the licensees records documenting drills and training, the inspector verified that CFD personnel were well trained, properly equipped, and knowledgeable of the actions to take in case of an emergency at the reactor facility. The inspector determined that the licensee was maintaining a good working relationship with this support group.

c.

Conclusion

Emergency response facilities and equipment were being maintained as required and responders were knowledgeable of proper actions to take in case of an emergency. Emergency support agreements were being maintained with appropriate offsite agencies. Annual drills were being held and the appropriate documentation was maintained. Emergency preparedness training for staff and off-site personnel was being conducted as required.

10.

Exit Interview

The inspection scope and results were summarized on January 30, 2014, with licensee representatives. The inspector discussed the findings for each area reviewed. The licensee acknowledged the findings and did not identify as proprietary any of the material provided to or reviewed by the inspector during the inspection of these program areas.

PARTIAL LIST OF PERSONS CONTACTED

Licensee Personnel

T. Keller Reactor Administrator S. Menn Senior Health Physicist Director, OSU Radiation Center R. Schickler Reactor Engineer S. Smith Development Engineer G. Wachs Reactor Supervisor

Other Personnel

D. Baily Battalion Commander, Corvallis Fire Department A. Klein Chair of the Reactor Operations Committee

INSPECTION PROCEDURE USED

IP 69001 Class II Non-Power Reactors IP 92701 Review of Previously Identified Items

ITEMS OPENED, CLOSED, AND DISCUSSED

Opened

None

Closed

None

LIST OF ACRONYMS USED

10 CFR Title 10 of the Code of Federal Regulations ANSI/ANS American National Standards Institute/American Nuclear Society CFD Corvallis Fire Department E-Plan Emergency Plan IP Inspection Procedure IR Irradiation Request LCO Limiting Conditions for Operation NRC Nuclear Regulatory Commission OSU Oregon State University OSTR Oregon State University TRIGA Reactor OSTROP Oregon State University TRIGA Reactor Operating Procedure RO Reactor Operator ROC Reactor Operations Committee SRO Senior Reactor Operator SSC Structures, systems, and components TS Technical Specifications