New Jersey Pollutant Discharge Elimination System Discharge Monitoring Report for Month of December 2013
ML14035A073
Person / Time
Site: Salem  
Issue date: 01/24/2014
From: Jamila Perry
Public Service Enterprise Group
To:
Office of Nuclear Reactor Regulation, State of NJ, Dept of Environmental Protection
References
NJ0005622, SCH-14-003
Download: ML14035A073 (36)


Text

PSEG Nuclear L.L.C.

P.O. Box 236, Hancocks Bridge. NJ 08302 SCH-14-003 CERTIFIED MAIL JAN 24 2014 1

RETURN RECEIPT REQUESTED PsEG ARTICLE NUMBER: 7012 1640 0000 4257 0267 Nuclear L.L.C.

Department of Environmental Protection Division of Water Quality Bureau of Permit Management P.O. Box 029 Trenton, N.J. 08625-0029 NEW JERSEY POLLUTANT DISCHARGE ELIMINATION SYSTEM DISCHARGE MONITORING REPORT SALEM GENERATING STATION NJPDES PERMIT NJ0005622

Dear Sir:

Attached is the Discharge Monitoring Report for the Salem Generating Station for the month of December 2013.

This report is required by and prepared specifically for the New Jersey Department of Environmental Protection (NJDEP).

It presents only the observed results of measurements and analyses required to be performed by the above agencies.

The choice of the measurement devices and analytical methods are controlled by the EPA and the NJDEP, not by the company, and there are limitations on the accuracy of such measurement devices and analytical techniques even when used and maintained as required. Accordingly, this report is not intended as an assertion that any instrument has measured, or that any reading or analytical result represents the true value with absolute accuracy, nor is it an endorsement of the suitability of any analytical or measurement procedure.

If you have any questions concerning this report, please feel free to contact Mark Pyle (856) 339-2331.

Sincerely, hnF. Perry Site Vice Presiden Salem Attachment (12 DMR's)

C Executive Director, DRBC USNRC - Docket numbers 50-272 & 50-311

EXPLANATION OF CONDITIONS Dec 2013 The following explanations are included to clarify possible deviation from permit conditions.

General - The columns labeled "No. Ex" on the enclosed DMR tabulate the number of daily discharge values outside the indicated limits.

Data reporting and accuracy reflect the working environment, the design capabilities and reliability of the monitoring instruments and operating equipment.

Deviations from required sampling, analysis monitoring and reporting methods and periodicities are noted on the respective transmittal sheet.

Results reported on the Discharge Monitoring Report forms are consistent with permit limits, data supplied from contract laboratories, the December 2007 revision of the NJDEP DMR Instruction Manual and specific guidance from DEP personnel.

ATTACHMENT:

Determination of circulating water flow at Salem Generating Station Unit 1

EXPLANATION OF EXCEEDANCES December 2013 The following exceedance(s) are included in the attached report and explained below.

EXPLANATION No Exceedances

COUNTY OF SALEM STATE OF NEW JERSEY I, John F. Perry, of full age, being duly sworn according to law, upon my oath depose and say:

1.

I am the Site Vice President - Salem for PSEG Nuclear, and as such am authorized to sign Salem's Discharge Monitoring Reports submitted to the New Jersey Department of Environmental Protection pursuant to the Station's New Jersey Pollutant Discharge Elimination System permit.

2.

I certify under penalty of law that I have personally examined and am familiar with the information submitted in this document and all attachments and that, based on my inquiry of those individuals immediately responsible for obtaining the information, I believe the submitted information is true, accurate and complete. I am aware that there are significant penalties for submitting false information including the possibility of fine and imprisonment.

3.

The signature on the attached Discharge Monitoring Reports is my signature and I am submitting this affidavit in satisfaction of the requirement that my signature be notarized.

John F. Perry Site Vice President -

alem Sworn andsubscribed before me thii, o,,N' day of January 2014

/ If__

NA CYM. GUNNING Jl~

~

  • .'.UNI'NG

/

Notary Public, State of New Jersey My Commission Expires September 22, 2014

New Jersey Department of Environmental Protection Division of Water Quality Surface Water Discharge Monitoring Report Submittal Form NJPDES PERMIT MONITORING PERIOD MONITORED LOCATION:

NJ0005622 Month D

To I Month I Day I Year FACA - SW Outfall FACA PERMITTEE:

PSE&G NUCLEAR LLC 80 PARK PLAZA NEWARK, NJ 07101 LOCATION OF ACTIVITY:

PSEG NUCLEAR LLC SALEM GENERATING STATION ALLOWAY CREEK NECK RD HANCOCKS BRIDGE, NJ 08038 REPORT RECIPIENT:

PSEG NUCLEAR LLC PO BOX 236/N21 HANCOCKS BRIDGE, NJ 08038 REGION / COUNTY: Southern / Salemi County CHECK IF APPLICABLE: El No Discharge this Monitoring Period 0I Monitoring Report Comments Attached WHO MUST SIGN The highest ranking official having day-to-day managerial and operational responsibilities for the discharging facility shall sign the certification or, in his absence a person designated by that person. For a local agency, the highest ranking operator of the treatment works shall sign the certification. Where the highest ranking operator does not have the ability to authorize capital expenditures and hire personnel, a person having that responsibility or person designated by that person shall also sign the second certification at the bottom of this page. If the local agency has contracted with another entity to operate the treatment works, the highest-ranking official of the contracted entity shall sign the certification.

I certify under penalty of law that I have personally examined and am familiar with the information submitted in this document and all attachments, and that, based on my inquiry of those individuals immediately responsible for obtaining the information, I believe that the information is true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of and/or imprisonment, pursuant to N.J.A.C. 7:14A-6.9(B). The New Jersey water Pollution Control Act provides for penalties up to $50,000 per violation.

John F. Pent-v, Site Vice President - Salem N/A NAME AND TITLE OF PRINCIPAL EXE IVE OFFICER, AUTHORIZED AGENT, OR *LICENSED OPERATOR GRADE AND REGISTRY NUMBER (IF APPLICABLE) 1/23/2014 856-339-3463 SIGNATURE 0-PRINCIPAL EXECUTIVE F

R, AUTHORIZED AGENT, OR *LICENSED OPERATOR DATE AREA CODE/PIIONE NUMBER

  • For a local agency where the highest-ran g operator does not have the ability to aitthorize capital expenditures and hirepersonnel, a person having that responsibility or person designated by that person shall sign the.1tlloiting certification:

I certify under penalty of law and in accordance with N.J.S.A. 58:1OA-6F(5) that I have reviewed the attached discharge monitoring reports.

N/A NAME AND TITLE N/A SIGNATURE DATE N/A N/A AREA CODE/PHONE NUMBER

Surface Water Discharge Monitoring Report PERMIT NUMBER:

MONITORED LOCATION:

MONITORING PERIOD:

FACILITY NAME:

NJ0005622 FACA SW Outfall FACA 121112013 TO 12/31/2013 PSEG NUCLEAR LLC SALEM GENERATIN P1 46814 Comments: If there are any questions in regards to the monitoring report form, please contact Susan Rosenwinkel of the BPSP - Region 2 at (609)292-4860 or via email at "srosenwi@dep.state.nj.us".

Pre-Print Creation Date: 101112013 Page 1 of 1

New Jersey Department of Environmental Protection Division of Water Quality Surface Water Discharge Monitoring Report Submittal Form NJPDES PERMIT MONITORING PERIOD MONITORED LOCATION:

NJ0005622 Month I Day I Year To Month Day Year FACB - SW Outfall FACB PERMITTEE:

PSE&G NUCLEAR LLC 80 PARK PLAZA NEWARK, NJ 07101 LOCATION OF ACTIVITY:

PSEG NUCLEAR LLC SALEM GENERATING STATION ALLOWAY CREEK NECK RD HANCOCKS BRIDGE, NJ 08038 REPORT RECIPIENT:

PSEG NUCLEAR LLC PO BOX 236/N21 HANCOCKS BRIDGE, NJ 08038 REGION / COUNTY: Southern / Salem County CHECK IF APPLICABLE:

No Discharge this Monitoring Period E] Monitoring Report Comments Attached WHO MUST SIGN The highest ranking official having day-to-day managerial and operational responsibilities for the discharging facility shall sign the certification or, in his absence a person designated by that person. For a local agency, the highest ranking operator of the treatment works shall sign the certification. Where the highest ranking operator does not have the ability to authorize capital expenditures and hire personnel, a person having that responsibility or person designated by that person shall also sign the second certification at the bottom of this page. If the local agency has contracted with another entity to operate the treatment works, the highest-ranking official of the contracted entity shall sign the certification.

I certify under penalty of law that I have personally examined and am familiar with the information submitted in this document and all attachments, and that, based on my inquiry of those individuals immediately responsible for obtaining the information, I believe that the information is true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of and/or imprisonment, pursuant to N.J.A.C. 7:14A-6.9(B). The New Jersey water Pollution Control Act provides for penalties up to $50,000 per violation.

John F. PenT, Site Vice President - Salem N/A NAME AND TITLE OF PRINCIPAL EXECUT OFFICER, AUTIIORIZED AGENT, OR *LICENSED OPERATOR GRADE AND REGISTRY NUMBER (IF APPLICABLE) 1/23/2014 856-339-3463 SIGNATURE 0 PRINCIPAL EXECUTIVE OFFIC

, WTHORIZED AGENT, OR *LICENSED OPERATOR DATE AREA CODE/PIHONE NUMBER

  • For a local agencq, where the highest-rankin o era/or does not have the ability to authorize capital expenditures and hire pe*sonnel, a person having that responsibility or person designated by that person shall sign the following certification:

I certify under penalty of law and in accordance with N.J.S.A. 58:1OA-6F(5) that I have reviewed the attached discharge monitoring reports.

N/A N/A NAME AND TITLE SIGNATURE N/A N/A AREA CODE/PtIONE NUMBER DATE

Surface Water Discharge Monitoring Report PERMIT NUMBER:

MONITORED LOCATION:

I NJ0005622 FACB SW Outfall FACB 1

PI 46814

'lONITORING PERIOD:

2/1/2013 TO 12/31/2013 FACILITY NAME:.

PSEG NUCLEAR LLC SALEM GENERATIN Comments: If there are any questions in regards to the monitoring report form, please contact Susan Rosenwinkel of the BPSP - Region 2 at (609)292-4860 or via email at "srosenwi@dep.state.nj.us". k Pre-Pinf Creation Date: 10/1/20 13 Page 1 of IIj Pre-Pfint Creatiofi Date: 101112013 Page I of I

New Jersey Department of Environmental Protection Division of Water Quality Surface Water Discharge Monitoring Report Submittal Form NJPDES PERMIT MONITORING PERIOD MONITORED LOCATION:

NJ0005622 Month I Day Year omontDay ea2 FACC - SW Outfall FACC NJ 00 62 1-2 1

2 13 T° 12 I31 1 20131 PERMITTEE:

PSE&G NUCLEAR LLC 80 PARK PLAZA NEWARK, NJ 07101 LOCATION OF ACTIVITY:

PSEG NUCLEAR LLC SALEM GENERATING STATION ALLOWAY CREEK NECK RD HANCOCKS BRIDGE, NJ 08038 REPORT RECIPIENT:

PSEG NUCLEAR LLC PO BOX 236/N21 HANCOCKS BRIDGE, NJ 08038 REGION / COUNTY: Southern / Salem County CHECK IF APPLICABLE:

0I No Discharge this Monitoring Period L--

Monitoring Report Comments Attached WHO MUST SIGN The highest ranking official having day-to-day managerial and operational responsibilities for the discharging facility shall sign the certification or, in his absence a person designated by that person. For a local agency, the highest ranking operator of the treatment works shall sign the certification. Where the highest ranking operator does not have the ability to authorize capital expenditures and hire personnel, a person having that responsibility or person designated by that person shall also sign the second certification at the bottom of this page. If the local agency has contracted with another entity to operate the treatment works, the highest-ranking official of the contracted entity shall sign the certification.

I certify under penalty of law that I have personally examined and am familiar with the information submitted in this document and all attachments, and that, based on nmy inquiry of those individuals immediately responsible for obtaining the information, I believe that the information is true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of and/or imprisonment, pursuant to N.J.A.C. 7:14A-6.9(B). The New Jersey water Pollution Control Act provides for penalties up to $50,000 per violation.

John F. Pen-, Site Vice President - Salem N/A NAME AND TILE OF PRINCIPAL XECUTIVE OFFICER, AUTIIORIZED AGENT, OR *LICENSED OPERATOR GRADE AND REGISTRY NUMBER (IF APPLICABLE) 1/23/2014 856-339-3463 SIGNAT E OF PRINCIPAL EXECUT "FFICER, AUTHORIZED AGENT, OR *LICENSED OPERATOR DATE AREA CODE/PIIONE NUMBER

  • For a local agency wVhere the highe - anking operator does not have the ability to autthorize capital e.xpenditutres adt hire pem.oinel, a person having that responsibility or person designated bhi that person shall sign the following certlfication:

I certify under penalty of law and in accordance with N.J.S.A. 58:1OA-6F(5) that I have reviewed the attached discharge monitoring reports.

N/A N/A NAME AND TITLE SIGNATURE N/A N/A DATE AREA CODE/PIIONE NUMBER

Surface Water Discharge Monitoring Report PERMIT NUMBER:

MONITORED LOCATION:

MONITORING PERIOD:

NJ0005622 FACC SW Outfall FACC 12/1/2013 TO 12/31/2013 P1 46814 FACILITY NAME:

PSEG NUCLEAR LLC SALEM GENERATIN Comments: If there are any questions in regards to the monitoring report form, please contact Susan Rosenwinkel of the BPSP - Region 2 at (609)292-4860 or via email at "srosenwi@dep.state.nj.us".

Pre-Print Creation Date: 10/1/2013 Page 1 of 1

New Jersey Department of Environmental Protection Division of Water Quality Surface Water Discharge Monitoring Report Submittal Form NJPDES PERMIT MONITORING PERIOD MONITORED LOCATION:

NJ0005622 Month I Day I Yea2 To Month Day Year 048C - SW Outfall 48C PERMITTEE:

PSE&G NUCLEAR LLC 80 PARK PLAZA NEWARK, NJ 07101 LOCATION OF ACTIVITY:

PSEG NUCLEAR LLC SALEM GENERATING STATION ALLOWAY CREEK NECK RD HANCOCKS BRIDGE, NJ 08038 REPORT RECIPIENT:

PSEG NUCLEAR LLC PO BOX 236/N2 1 H-TANCOCKS BRIDGE, NJ 08038 REGION / COUNTY: Southern / Salem County CHECK IF APPLICABLE:

[3 No Discharge this Monitoring Period L-- Monitoring Report Comments Attached WI-O MUST SIGN The highest ranking official having day-to-day managerial and operational responsibilities for the discharging facility shall sign the certification or, in his absence a person designated by that person. For a local agency, the highest ranking operator of the treatment works shall sign the certification. Where the highest ranking operator does not have the ability to authorize capital expenditures and hire personnel, a person having that responsibility or person designated by that person shall also sign the second certification at the bottom of this page. If the local agency has contracted with another entity to operate the treatment works, the highest-ranking official of the contracted entity shall sign the certification.

I certify under penalty of law that I have personally examined and am familiar with the information submitted in this document and all attachments, and that, based on my inquiry of those individuals immediately responsible for obtaining the information, I believe that the information is true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of and/or imprisonment, pursuant to N.J.A.C. 7:14A-6.9(B). The New Jersey water Pollution Control Act provides for penalties up to $50,000 per violation.

John F. Perry, Site Vice President - Salem N/A NAME AND TIT OF PRINCIPAL EXE UTIVE OFFICER, AUTHORIZED AGENT, OR *LICENSED OPERATOR GRADE AND REGISTRY NUMBER (IF APPLICABLE) 1/23/2014 856-339-3463 SIGNATU /,OF PRINCIPAL EXECUTIVE,rCER, AUTHORIZED AGENT, OR *LICENSED OPERATOR DATE AREA CODE/PtlONE NUMBER

  • For a local agency where the highest-r ng operator does not have the ability to authorize capital expenditures and hire personnel, a person having that responsibility or person designated bv that person shall sign the following certification:

I certify under penalty of law and in accordance with N.J.S.A. 58:IOA-6F(5) that I have reviewed the attached discharge monitoring reports.

N/A N/A NAME AND TITLE SIGNATURE N/A N/A DATE AREA CODE/PHONE NUMBER

Surface Water Discharge Monitoring Report P1 46814 PERMIT NUMBER:

MONITORED LOCATION:

NJ0005622 048C SW Outfall 48C MONITORING PERIOD:

FACILITY NAME:

12/1/2013 TO 12/31/2013 PSEG NUCLEAR LLC SALEM GENERATIN Comments: If there are any questions in regards to the monitoring report form, please contact Susan Rosenwinkel of the BPSP - Region 2 at (609)292-4680 or via email at "srosenwi@dep.state.nj.us".

Pre-Print Creation Date: 10/1/2013 Page 1 of 1

New Jersey Department of Environmental Protection Division of Water Quality Surface Water Discharge Monitoring Report Submittal Form NJPDES PERMIT MONITORING PERIOD MONITORED LOCATION:

NJ0005622 Month I DaY j Year To IMn I 1

o13 481A - SW Outfall 481A PERMITTEE:

PSE&G NUCLEAR LLC 80 PARK PLAZA NEWARK, NJ 07101 LOCATION OF ACTIVITY:

PSEG NUCLEAR LLC SALEM GENERATING STATION ALLOWAY CREEK NECK RD HANCOCKS BRIDGE, NJ 08038 REPORT RECIPIENT:

PSEG NUCLEAR LLC PO BOX 236/N21 HANCOCKS BRIDGE, NJ 08038 REGION / COUNTY: Southern / Salem County CHECK IF APPLICABLE: E-No Discharge this Monitoring Period El Monitoring Report Comments Attached WHO MUST SIGN The highest ranking official having day-to-day managerial and operational responsibilities for the discharging facility shall sign the certification or, in his absence a person designated by that person. For a local agency, the highest ranking operator of the treatment works shall sign the certification. Where the highest ranking operator does not have the ability to authorize capital expenditures and hire personnel, a person having that responsibility or person designated by that person shall also sign the second certification at the bottom of this page. If the local agency has contracted with another entity to operate the treatment works, the highest-ranking official of the contracted entity shall sign the certification.

I certify under penalty of law that I have personally examined and am familiar with the information submitted in this document and all attachments, and that, based on my inquiry of those individuals immediately responsible for obtaining the information, I believe that the information is true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of and/or imprisonment, pursuant to N.J.A.C. 7:14A-6.9(B). The New Jersey water Pollution Control Act provides for penalties up to $50,000 per violation.

John F. Perrm. Site Vice President - Salem N/A NAME AND TITl OF PRINCIPAL EXECUTIVE OFFICER, AUTHORIZED AGENT, OR *LICENSED OPERATOR GRADE AND REGISTRY NUMBER (IF APPLICABLE) 1/23/2014 856-339-3463 SIGNATU OF PRINCIPAL EXECUTIVE OF R, AUTIIORIZED AGENT, OR *LICENSED OPERATOR DATE AREA CODE/PIIONE NUMBER

  • For a local agency where the highes-ra dk g operator docs not have the ability to amthorize calpital expenditures and hire personnel, a person haviing that responsibility or person designated by1 that person shall sign the following certification:

I certify Under penalty of law and in accordance with N.J.S.A. 58:IOA-6F(5) that I have reviewed the attached discharge monitoring reports.

N/A N/A NAME AND TITLE SIGNATURE N/A N/A DATE AREA CODE/PHONE NUMBER

Surface Water Discharge Monitoring Report PERMIT NUMBER:

MONITORED LOCATION:

MONITORING PERIOD:

FAC NJ0005622 481A SW Outfall 481A 121112013 TO 1213112013 PSE PI 46814 ILITY NAME' G NUCLEAR LLC SALEM GENERATIN Comments: The permittee is required to perform acute toxicity testing on a minimum of one representative CWS outfall while DSN 48C is being routed to that outfall.

Pre-Print Creation Date: 101112013 Page 1 of 2

Surface Water Discharge Monitoring Report PERMIT NUMBER:

MONITORED LOCATION:

MONITORING PERIOD:

NJ0005622 481A SW Outfall 481A 1211/2013 TO 12/31/2013 PI 46814 FACILITY NAME:

PSEG NUCLEAR LLC SALEM GENERATIN Comments: The permittee is required to perform acute toxicity testing on a minimum of one representative CWS outfall while DSN 48C is being routed to that outfall.

Pre-Print Creation Date: 101112013 Page 2 of 2

New Jersey Department of Environmental Protection Division of Water Quality Surface Water Discharge Monitoring Report Submittal Form NJPDES PERMIT MONITORING PERIOD MONITORED LOCATION:

NJ0005622 Month1 DaYl I Year To

_12

] Day Ye21 I 482A - SW Outfall 482A 12 1 2013 LjJL 31 013 PERMITTEE:

LOCATION OF ACTIVITY:

REPORT RECIPIENT:

PSE&G NUCLEAR LLC PSEG NUCLEAR LLC SALEM PSEG NUCLEAR LLC 80 PARK PLAZA GENERATING STATION PO BOX 236/N21 NEWARK, NJ 07101 ALLOWAY CREEK NECK RD HANCOCKS BRIDGE, NJ 08038 HANCOCKS BRIDGE, NJ 08038 REGION / COUNTY: Southern / Salem County CHECK IF APPLICABLE: El No Discharge this Monitoring Period E] Monitoring Report Comments Attached WHO MUST SIGN The highest ranking official having day-to-day managerial and operational responsibilities for the discharging facility shall sign the certification or, in his absence a person designated by that person. For a local agency, the highest ranking operator of the treatment works shall sign the certification. Where the highest ranking operator does not have the ability to authorize capital expenditures and hire personnel, a person having that responsibility or person designated by that person shall also sign the second certification at the bottom of this page. If the local agency has contracted with another entity to operate the treatment works, the highest-ranking official of the contracted entity shall sign the certification.

I certify under penalty of law that I have personally examined and am familiar with the information submitted in this document and all attachments, and that, based on my inquiry of those individuals immediately responsible for obtaining the information, I believe that the information is true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of and/or imprisonment, pursuant to N.J.A.C. 7:14A-6.9(B). The New Jersey water Pollution Control Act provides for penalties tip to $50,000 per violation.

John F. Perry, Site Vice President - Salem N/A NAME AND TITLE OF PRINCIPAL EXECUTIVE OFFICER, AUTHORIZED AGENT, OR *LICENSED OPERATOR GRADE AND REGISTRY NUMBER (IF APPLICABLE) 1/23/2014 856-339-3463 SIGNATUVOF PRINCI PAL EXECUTIVE I ER UTHIORIZED AGENT, OR -LICENSED OPERATOR DATE AREA CODE/PIIONE NUMBER

  • For a local ae-cv where i

g operator does not hale i/e ability to authorize capital expenditures and hire personnel. a person hating that responsibility or person designated bhi that person shall.

tie Ib/lowiig certificatioi."

I certify under penalty of law and in accordance with N.J.S.A. 58:10A-6F(5) that I have reviewed the attached discharge monitoring reports.

N/A N/A N/A N/A NAME AND TITLE SIGNATURE DATE AREA CODE/PHONE NUMBER

Surface Water Discharge Monitoring Report PI 46814 PERMIT NUMBER:

NJ0005622 MONITORED LOCATION:

482A SW Outfall 482A MONITORING PERIOD:

121112013 TO 12131/2013 FACILITY NAME:

PSEG NUCLEAR LLC SALEM GENERATIN Comments: The permittee is required to perform acute toxicity testing on a minimum of one representative CWS outfall while DSN 48C is being routed to that outfall.

Pre-Print Creation Date: 10/1/20 13 Page 1 of 2 Pre-Print Creation Date: 101112013 Page 1 of 2

Surface Water Discharge Monitoring Report PERMIT NUMBER:

MONITORED LOCATION:

N NJ0005622 482A SW Outfall 482A I

PI 46814 IONITORING PERIOD:

FACILITY NAME:

2/112013 TO 12/3112013 PSEG NUCLEAR LLC SALEM GENERATIN Comments: The permittee is required to perform acute toxicity testing on a minimum of one representative OWS outfall while DSN 48C is being routed to that outfall..

Pre-Print Creation Date: 101112013 Page 2 of 2

New Jersey Department of Environmental Protection Division of Water Quality Surface Water Discharge Monitoring Report Submittal Form NJPDES PERMIT MONITORING PERIOD MONITORED LOCATION:

NJ0005622 MonthI Y

483A - SW Outfeall 483A 12 1

2013 To J23 20 3

PERMITTEE:

PSE&G NUCLEAR LLC 80 PARK PLAZA NEWARK, NJ 07101 LOCATION OF ACTIVITY:

PSEG NUCLEAR LLC SALEM GENERATING STATION ALLOWAY CREEK NECK RD HANCOCKS BRIDGE, NJ 08038 REPORT RECIPIENT:

PSEG NUCLEAR LLC PO BOX 236/N21 HANCOCKS BRIDGE, NJ 08038 REGION / COUNTY: Southern / Salem County CHECK IF APPLICABLE: D No Discharge this Monitoring Period

--- Monitoring Report Comments Attached WHO MUST SIGN The highest ranking official having day-to-day managerial and operational responsibilities for the discharging facility shall sign the certification or, in his absence a person designated by that person. For a local agency, the highest ranking operator of the treatment works shall sign the certification. Where the highest ranking operator does not have the ability to authorize capital expenditures and hire personnel, a person having that responsibility or person designated by that person shall also sign the second certification at the bottom of this page. If the local agency has contracted with another entity to operate the treatment works, the highest-ranking official of the contracted entity shall sign the certification.

I certify under penalty of law that I have personally examined and am familiar with the information submitted in this document and all attachments, and that, based on my inquiry of those individuals immediately responsible for obtaining the information, I believe that the information is true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of and/or imprisonment, pursuant to N.J.A.C. 7:14A-6.9(B). The New Jersey water Pollution Control Act provides for penalties up to $50,000 per violation.

John F. PerTv. Site Vice President - Salem N/A NAME AND TITLE OF PRINCIPAL EX UTIVE OFFICER, AUTHORIZED AGENT, OR *LICENSED OPERATOR GRADE AND REGISTRY NUMBER (IF APPLICABLE) 411 4__/

Pý2_j

ý1/23/20 14 856-339-3463 SIGNATUXE OF PRINCIPAL EXECUTIVE 0 R, AUTHORIZED AGENT, OR *LICENSED OPERATOR DATE AREA CODE/PHONE NUMBER

  • For a local agenci where the highest-r17k -g operator does not hav'e the aohilitv to authorize capital expenditures and hire personnel, a person having that responsibility or perton cdesignated bl that person shalln thea od lowing cer.ification:

I certify tUnder penalty of law and in accordance with N.J.S.A. 58:10A-6F(5) that I have reviewed the attached discharge monitoring reports.

N/A N/A NAME AND TITLE SIGNATURE N/A N/A AREA CODE/PIIONE NUMBER DATE

Surface Water Discharge Monitoring Report PI 46814 PERMIT NUMBER:

NJ0005622 MONITORED LOCATION:

MONITORING PERIOD:

12/1/2013 TO 12/31/2013 FACILITY NAME:

483A SW Outfall 483A PSEG NUCLEAR LLC SALEM GENERATIN Comments: Any questions in regards to the monitoring report form can be directed to S. Rosenwinkel of the BPSP - Region 2 at (609)292-4860.

Pre-Print Creation Date: 101112013 Page I of 2

Surface Water Discharge Monitoring Report P1 46814 PERMIT NUMBER:

MONITORED LOCATION:

NJ0005622 483A SW Outfall 483A MONITORING PERIOD:

121112013 TO 1213112013 FACILITY NAME:

PSEG NUCLEAR LLC SALEM GENERATIN Comments: Any questions in regards to the monitoring report form can be directed to S. Rosenwinkel of the BPSP - Region 2 at (609)292-4860.

Pre-Piint CreatiO17 Date.- 101112013 Page 2 of 2

New Jersey Department of Environmental Protection Division of Water Quality Surface Water Discharge Monitoring Report Submittal Form NJPDES PERMIT MONITORING PERIOD MONITORED LOCATION:

NJ0005622 Monithl2 Day ol03 To IMonth2 DA1 Year3 484A - SW Outfall 484A PERMITTEE:

LOCATION OF ACTIVITY:

REPORT RECIPIENT:

PSE&G NUCLEAR LLC PSEG NUCLEAR LLC SALEM PSEG NUCLEAR LLC 80 PARK PLAZA GENERATING STATION PO BOX 236/N21 NEWARK, NJ 07101 ALLOWAY CREEK NECK RD HANCOCKS BRIDGE, NJ 08038 HANCOCKS BRIDGE, NJ 08038 REGION / COUNTY: Southern / Salem County CHECK IF APPLICABLE:

No Discharge this Monitoring Period Monitoring Report Comments Attached WHO MUST SIGN The highest ranking official having day-to-day managerial and operational responsibilities for the discharging facility shall sign the certification or, in his absence a person designated by that person. For a local agency, the highest ranking operator of the treatment works shall sign the certification. Where the highest ranking operator does not have the ability to authorize capital expenditures and hire personnel, a person having that responsibility or person designated by that person shall also sign the second certification at the bottom of this page. If the local agency has contracted with another entity to operate the treatment works, the highest-ranking official of the contracted entity shall sign the certification.

I certify under penalty of law that I have personally examined and am familiar with the information submitted in this document and all attachments, and that, based on my inquiry of those individuals immediately responsible for obtaining the information, I believe that the information is true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of and/or imprisonment, pursuant to N.J.A.C. 7:14A-6.9(B). The New Jersey water Pollution Control Act provides for penalties up to $50,000 per violation.

John F. Perry, Site Vice President - Salem N/A NAME AND TITLE OF PRINCIPAL EXECUTIVE OFFICER, AUTHORIZED AGENT, OR *LICENSED OPERATOR GRADE AND REGISTRY NUMBER (IF APPLICABLE)

Z"-ý

ý 1/23/2014 856-339-3463 SIGNATYRE OF PRINCIPAL EXECUTIVE CER, AUTHORIZED AGENT, OR *LICENSED OPERATOR DATE AREA CODE/PHONE NUMBER

  • For a local agency where the highes -ra aug operator does not have the ability to auithorize caJ)ital expenditures and hirepensonnel. a person having that responsibility or person desiýnated bh. that person sha siign the follow'ing ceritficatiioi:

I certify under penalty of law and in accordance with N.J.S.A. 58:1 OA-6F(5) that I have reviewed the attached discharge monitoring reports.

N/A N/A N/A N/A NAME AND TITLE SIGNATURE DATE AREA CODE/PHONE NUMBER

Surface Water Discharge Monitoring Report PERMIT NUMBER:

MONITORED LOCATION:

MONITORING PERIOD:

FACILITY NAME:

NJ0005622 484A SW Outfall 484A 121112013 TO 1213112013 PSEG NUCLEAR LLC SALEM GENERATIN PI 46814 Comments: The permittee is required to perform acute toxicity testing on a minimum of one representative CWS outfall while DSN 48C is being routed to that outfall.

1 Pre-Print Creation Date: 10/1/20 13 Page 1 of 2I Pre-Print Creation Date: 101112013 Page I of 2

Surface Water Discharge Monitoring Report PERMIT NUMBER:

MONITORED LOCATION:

MONITORING PERIOD:

F-NJ0005622 484A SW Outfall 484A 1211/2013 TO 12/31/2013 F

PI 46814

-ACILITY NAME:

>SEG NUCLEAR LLC SALEM GENERATIN Comments: The permittee is required to perform acute toxicity testing on a minimum of one representative CWS outfall while DSN 48C is being routed to that outfall.

Pre-Print Creation Date: 101112013 Page 2 of 2

New Jersey Department of Environmental Protection Division of Water Quality Surface Water Discharge Monitoring Report Submittal Form NJPDES PERMIT MONITORING PERIOD MONITORED LOCATION:

NJ0005622 Month Day I Year T

month] Day ]Yea 4

NJ0062 1

1 203 o

j

  • 13 485A - SW Outfall 485A 12 1

2013 To 12

]31 12013 PERMITTEE:

LOCATION OF ACTIVITY:

REPORT RECIPIENT:

PSE&G NUCLEAR LLC PSEG NUCLEAR LLC SALEM PSEG NUCLEAR LLC 80 PARK PLAZA GENERATING STATION P0 BOX 236/N21 NEWARK, NJ 07101 ALLOWAY CREEK NECK RD HANCOCKS BRIDGE, NJ 08038 HANCOCKS BRIDGE, NJ 08038 REGION / COUNTY: Soutlherni / Sallem County CHECK IF APPLICABLE:

E-No Discharge this Monitoring Period El Monitoring Report Comments Attached WHO MUST SIGN The highest ranking official having day-to-day managerial and operational responsibilities for the discharging facility shall sign the certification or, in his absence a person designated by that person. For a local agency, the highest ranking operator of the treatment works shall sign the certification. Where the highest ranking operator does not have the ability to authorize capital expenditures and hire personnel, a person having that responsibility or person designated by that person shall also sign the second certification at the bottom of this page. If the local agency has contracted with another entity to operate the treatment works, the highest-ranking official of the contracted entity shall sign the certification.

I certify under penalty of law that I have personally examined and am familiar with the information submitted in this document and all attachments, and that, based on mny inquiry of those individuals immediately responsible for obtaining the information, I believe that the information is true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of and/or imprisonment, pursuant to N.J.A.C. 7:14A-6.9(B). The New Jersey water Pollution Control Act provides for penalties up to $50,000 per violation.

John F. Pen, Site Vice President - Salem N/A NAME ANITLE OF PRINCI PALXECUTIVE OFFICER, AUTHORIZED AGENT, OR *LICENSED OPERATOR GRADE AND REGISTRY NUMBER (IF APPLICABLE) 6_.

.1/23/2014 856-339-3463 SIGN/

URE OF PRINCIPAL EXECUTIV IFICER, AUTHORIZED AGENT, OR *LICENSED OPERATOR DATE AREA CODE/PHONE NUMBER

  • For a local agency where the hig es ranking operator does not have the ability to authorize capital e.*7pendituires. and hire personnel, a person having that responsibility or person designated by that person t,5all sign the following certification:

I certify under penalty of law and in accordance with N.J.S.A. 58: 10A-6F(5) that I have reviewed the attached discharge monitoring reports.

N/A N/A N/A N/A NAME AND TITLE SIGNATURE DATE AREA CODE/PHONE NUMBER

Surface Water Discharge Monitoring Repor PERMIT NUMBER:

NJ0005622 MONITORED LOCATION:

t MONITORING PERIOD:

FACILITY NAME:

121112013 TO 12/31/2013 PSEG NUCLEAR LLC SALEM GENERATIN P1 46814 485A SW Outfall 485A Comments: The permittee is required to perform acute toxicity testing on a minimum of one representative CWS outfall while DSN 48C is being routed to that outfall.

Pre-Print Creation Date: 101112013 Page 1 of 2

Surface Water Discharge Monitoring Report PERMIT NUMBER:

MONITORED LOCATION:

A NJ0005622 485A SW Outfall 485A 1

PI 46814 4ONITORING PERIOD 2/1/2013 TO 12/311201 FACILITY NAME:

13 PSEG NUCLEAR LLC SALEM GENERATIN Comments: The permittee is required to perform acute toxicity testing on a minimum of one representative CWS outfall while DSN 48C is being routed to that outfall.

Pre-Print Creation Date: 101112013 Page 2 of 2

New Jersey Department of Environmental Protection Division of Water Quality Surface Water Discharge Monitoring Report Submittal Form NJPDES PERMIT MONITORING PERIOD MONITORED LOCATION:

NJO005622 Imonith=IDay IYear ITo Alont a

eId 46 WO t l46 12 1

2013,

[ y oa-486A - SW. Outfall 486A N 0062

!12 11 2013 TO 12 131 120ý13 PERMITTEE:

LOCATION OF ACTIVITY:

REPORT RECIPIENT:

PSE&G NUCLEAR LLC PSEG NUCLEAR LLC SALEM PSEG NUCLEAR LLC 80 PARK PLAZA GENERATING STATION PO BOX 236/N2 1 NEWARK, NJ 07101 ALLOWAY CREEK NECK RD HANCOCKS BRIDGE, NJ 08038 HANCOCKS BRIDGE, NJ 08038 REGION / COUNTY: Southierin / Salem County CHECK IF APPLICABLE:

D_-

No Discharge this Monitoring Period Monitoring Report Comments Attached WHO MUST SIGN The highest ranking official having day-to-day managerial and operational responsibilities for the discharging facility shall sign the certification or, in his absence a person designated by that person. For a local agency, the highest ranking operator of the treatment works shall sign the certification. Where the highest ranking operator does not have the ability to authorize capital expenditures and hire personnel, a person having that responsibility or person designated by that person shall also sign the second certification at the bottom of this page. If the local agency has contracted with another entity to operate the treatment works, the highest-ranking official of the contracted entity shall sign the certification.

I certify under penalty of law that I have personally examined and am familiar with the information submitted in this document and all attachments, and that, based on my inquiry of those individuals immediately responsible for obtaining tile information, I believe that tile information is true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of and/or imprisonment, pursuant to N.J.A.C. 7:14A-6.9(B). The New Jersey water PollutionControl Act provides for penalties up to $50,000 per violation.

John F. Perry, Site Vice President - Salem N/A NAME AND TITLE OF PRINCIPA>1-XECUTIVE OFFICER, AUTHORIZED AGENT, OR *LICENSED OPERATOR GRADE AND REGISTRY NUMBER (IF APPLICABLE) 7a 1/23/2014 856-339-3463 SIGNAT /RE OF PRINCIPAL EXECUTI FFICER, AUTHORIZED AGENT, OR -LICENSED OPERATOR DATE AREA CODE/PHONE NUMBER

  • For a local ageny where the hig perator does not have the ability to authorize capital expenditures aond hire personnel, a persoii havinq that responsibility or per-son desigate fo ht g

llo)whtgj~

certification7."

I certify under penalty of law and in accordance with N.J.S.A. 58:1OA-6F(5) that I have reviewed the attached discharge monitoring reports.

N/A N/A N/A N/A NAME AND TITLE SIGNATURE DATE AREA CODE/PHlONE NUMBER

Surface Water Discharge Monitoring Report PERMIT NUMBER:

MONITORED LOCATION.

MONITORING PERIOD:

NJ0005622 486A SW Outfall 486A 121112013 TO 12131/2013 PI 46814 FACILITY NAME.

PSEG NUCLEAR LLC SALEM GENERATIN Comments: Any questions in regards to the monitoring report form can be directed to S. Rosenwinkel of the BPSP - Region 2 at (609)292-4860.

Pre-Print Creation Date: 101112013 Page 1 of 2

Surface Water Discharge Monitoring Report PERMIT NUMBER:

MONITORED LOCATION:

MONITORING PERIOD' NJ0005622 486A SW Outfall 486A 12/1/2013 TO 12/31/2013 PI 46814 FACILITY NAME:

PSEG NUCLEAR LLC SALEM GENERATIN Comments: Any questions in regards to the monitoring report form can be directed to S. Rosenwinkel of the BPSP - Region 2 at (609)292-4860.

Pre-Ptint Creation Date: 101112013 Page 2 of 2

New Jersey Department of Environmental Protection Division of Water Quality Surface Water Discharge Monitoring Report Submittal Form NJPDES PERMIT MONITORING PERIOD MONITORED LOCATION:

NJ0005622 I Month I Day I Year To Month Day ear 487B-SW Outfall 487B 1

12

ý 12 31 1Y201 PERMITTEE:

PSE&G NUCLEAR LLC 80 PARK PLAZA NEWARK, NJ 07101 CHECK IF APPLICABLE:

LOCATION OF ACTIVITY:

PSEG NUCLEAR LLC SALEM GENERATING STATION ALLOWAY CREEK NECK RD HANCOCKS BRIDGE, NJ 08038 REPORT RECIPIENT:

PSEG NUCLEAR LLC PO BOX 236/N21 HANCOCKS BRIDGE, NJ 08038 REGION / COUNTY: Southern / Salem County No Discharge this Monitoring Period E-Monitoring Report Comments Attached W1HO MUST SIGN The highest ranking official having day-to-day managerial and operational responsibilities for the discharging facility shall sign the certification or, in his absence a person designated by that person. For a local agency, the highest ranking operator of the treatment works shall sign the certification. Where the highest ranking operator does not have the ability to authorize capital expenditures and hire personnel, a person having that responsibility or person designated by that person shall also sign the second certification at the bottom of this page. If the local agency has contracted with another entity to operate the treatment works, the highest-ranking official of the contracted entity shall sign the certification.

I certify under penalty of law that I have personally examined and am familiar with the information submitted in this document and all attachments, and that, based on my inquiry of those individuals immediately responsible for obtaining the information, I believe that the information is true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of and/or imprisonment, pursuant to N.J.A.C. 7:14A-6.9(B). The New Jersey water Pollution Control Act provides for penalties up to $50,000 per violation.

John F. Perty, Site Vice President - Salem NAME AND ITLE OF PRINCIPAL EXECUTIVE OFFICER, AUTHORIZED AGENT, OR *LICENSED OPERATOR N/A GRADE AND REGISTRY NUMBER (IF APPLICABLE) 1/23/2014 856-339-3463 SIGNEURE OF PRINCIPAL EXEC

hCER, AUTHORIZED AGENT, OR *LICENSED OPERATOR DATE AREA CODE/PHONE NUMBER
  • For a local agenc where the I.

ranking operator does not a te li to at ize capital expenditures and hirepersonnel. a person having that responsibilit, or person designated`b that ll sign the following certification I certify Under penalty of law and in accordance with N.J.S.A. 58:1OA-6F(5) that I have reviewed the attached discharge monitoring reports.

N/A N/A NAME AND TITLE SIGNATURE N/A N/A AREA CODE/PHONE NUMBER DATE

New Jersey Department of Environmental Protection Division of Water Quality Surface Water Discharge Monitoring Report Submittal Form NJPDES PERMIT MONITORING PERIOD MONITORED LOCATION:

NJ0005622 Month Day Year To Month DaYear 489A - SW Outfall 489A 12 1

2013 11 1

21 PERMITTEE:

PSE&G NUCLEAR LLC 80 PARK PLAZA NEWARK, NJ 07101 LOCATION OF ACTIVITY:

PSEG NUCLEAR LLC SALEM GENERATING STATION ALLOWAY CREEK NECK RD HANCOCKS BRIDGE, NJ 08038 REPORT RECIPIENT:

PSEG NUCLEAR LLC PO BOX 236/N21 HANCOCKS BRIDGE, NJ 08038 REGION / COUNTY: Southern / Salem County CHECK IW APPLICABLE:

No Discharge this Monitoring Period L--I Monitoring Report Comments Attached WHO MUST SIGN The highest ranking official having day-to-day managerial and operational responsibilities for the discharging facility shall sign the certification or, in his absence a person designated by that person. For a local agency, the highest ranking operator of the treatment works shall sign the certification. Where the highest ranking operator does not have the ability to authorize capital expenditures and hire personnel, a person having that responsibility or person designated by that person shall also sign the second certification at the bottom of this page. If the local agency has contracted with another entity to operate the treatment works, the highest-ranking official of the contracted entity shall sign the certification.

I certify under penalty of law that I have personally examined and am familiar with the information submnitted in this document and all attachments, and that, based on my inquiry of those individuals immediately responsible for obtaining the information, I believe that the information is true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of and/or imprisonment, pursuant to N.J.A.C. 7:14A-6.9(B). The New Jersey water Pollution Control Act provides for penalties up to $50,000 per violation.

John F. Perry, Site Vice President - Salem NAME AND'ITLE OF PRINCIP XECUTIVE OFFICER, AUTHORIZED AGENT, OR *LICENSED OPERATOR N/A GRADE AND REGISTRY NUMBER (IF APPLICABLE) 1/23/2014 856-339-3463 SIGNY(URE OF PRINCIPAL EXECUye/OFFICER, AUTHORIZED AGENT, OR *LICENSED OPERATOR DATE AREA CODE/PHONE NUMBER

  • For a local agency where the hi. te,-ranking operator does not have the ahiliti, to acuthorize capital expcnditures and hire plcisonnel, a person having that responsibility.' or person designated by thatperson ilall sign the following certification:

I certify under penalty of law and in accordance with N.J.S.A. 58:1OA-6F(5) that I have reviewed the attached discharge monitoring reports.

N/A N/A NAME AND TITLE SIGNATURE N/A N/A DATE AREA CODE/PIIONE NUMBER

Surface Water Discharge Monitoring Report PERMIT NUMBER:

MONITORED LOCA TION:

MONITORING PERIOD:

NJ0005622 489A SW Outfall 489A 12/1/2013 TO 12/31/2013 P1 46814 FACILITY NAME:

PSEG NUCLEAR LLC SALEM GENERATIN Comments: If there are any questions in regards to the monitoring report form, please contact Susan Rosenwinkel of the the BPSP - Region 2 at (609)292-4860 or via email at

'srosenwi@dep.state.nj. us".

Pre-Print Crealion Date:

10/1/2013 Page 1 of 1P Pre-Print Creation Date: 10/1/2013 Page I of 1

LABORATORY & TESTING SERVICES REPORT o PSEG Power LLC TO: Christopher E. White Nuclear Sr. Environmental Specialist Salem Environmental Affairs - PSEG Power December 2, 2013 Report No. MSPG13040

SUBJECT:

DETERMINATION OF CIRCULATING WATER FLOW AT SALEM GENERATING STATION UNIT I CONDUCTED BY:

Gary Floystad Sr. Test Engineer, PSEG Laboratory & Testing Services

SUMMARY

The Mechanical Systems Performance Group of PSEG Laboratory and Testing Services conducted a series of test runs at Salem Unit No. 1 to determine the capacities of the circulating water pumps as illustrated in the table below.

Work was performed under SAP work orders:

30263016, 30263067, 30263017, 30263018, 30263063, 30263019,60102948 Final results are as follows:

SUMMARY

OF TEST RESULTS Pump CMS Test Measured Pump Pump Total No.

Pump Date Pump Suction Discharge Static Desig.

Capacity Head Head Head

_(gpm)

(ft h2o)

(ft h2o)

(ft h2o) 11A F

11/20/2013 175954

-6.6 15.6 22.2 11B J

11/21/2013 181316

-8.7 15.6 24.3 12A None 11/21/2013 169098

-7.9 14.8 22.7

12B H

11/21/2013 178544

-7.3 17.1 24.4 13A L

11/22/2013 181745

-9.5 16.1 25.6 13B G

11/22/2013 182555

-7.5 13.8 21.3 Note: Pump suction heads and discharge heads were corrected to elevation 100.3'

Salem Generating Station - Unit No.1 Total Pump Head vs. Pump Flow

_0 E

3 (L

90 80 70 50 40 30 20 10 0

I I

X i

h-

  • hI I

N> - I

-i I

I I

I-I t

I I....

I. -

N

-H I

5,.

1 F--

I

-Th i

I

-t

-- I Guar. Point Pum p 11A (F)

_,Pump 11B (J) oPump 12A (7)

.Pump 12B (H) oPump 13A (L)

N Pump 13B (G)

L 7 I

.~~~~

~ ~...

  • i*

I....

.W

....~~~

J..............I..

L.........

Mn uManufecturerv Curve (total static hehd vsv flew)"-

Cf)

CD 3

CD W

CD

-0 02 C,)

.1 z

C:

03 0

CD CD

_0 0) 0 in

d i..........

i........

S1 The data pointsashown represent measured pump flow plotted I

lagainst total static head. The velocity head has not been

.acounted for in Ihe data.'

-I I

F i

I i

I 0

50 100 Pump Flow - 1000 oDm 150 200 250 CD

ý10 0

z 0

C) 41.

C:

0CD 0(D CD C1 (D

-4.

Christopher E. White Nuclear Sr. Environmental Specialist Salem Environmental Affairs - PSEG Power December 2, 2013 Report No. MSPG13040 CONCLUSIONS For reporting purposes, shown below is the data pertinent to the injection of Rhodamine WT dye released to the river during testing. At this time testing is not complete at this station.

RECORD OF RHODAMINE WT DYE INJECTION (pursuant to additional testing)

Test Pump Injection Pure Number of Total Effluent Date No.

Time Dye Pumps in System Concentration Injected Service

  • Flow (start)

(stop)

(ml)

(1000 gpm)

(ppb) 11/2012013 11A 1139 1209 41.66 11 2035.0 0.18 11/21/2013 11B 957 1023 36.29 11 2035.0 0.18 11/21/2013 12A 1039 1106 37.93 11 2035.0 0.18 11/21/2013 12B 1119 1145 36.39 11 2035.0 0.18 11/22/2013 13A 951 1019 38.08 11 2035.0 0.18 11/22/2013 13B 1144 1210 35.25 11 2035.0 0.18 TEST METHOD The circulating water flow rate was determined by fluorometry using MTS Mechanical Division Work Instruction TPG-19 Rev. 13 "Water Flow Using The Turner Fluorometer". Rhodamine WT dye was injected into the bell mouth of each pump using 1/2 inc PVC pipe with a carrier flow of screen wash water at approximately 3 gallons per minute.

The dye was injected at a known rate using a peristaltic pump and a class A burette to measure rate. The diluted sample was retrieved and monitored by taking a sample from the inlet water box piping. The ratio of the injected concentration to the sample concentration multiplied by the injection flow rate yielded the circulator flow rate.

The total static head was obtained by measuring the pump suction head in feet from elevation 100.3' and the pump discharge head in feet of water at the water box inlet. After correcting for elevation, the total pump head was calculated as the pump discharge head minus the pump suction head.

ANSI Level II or III Evaluation Vic Simpson Senior Test Engineer LTS Mechanical Division