ML14014A276

From kanterella
Jump to navigation Jump to search
Reply to Request for Additional Information Regarding the License Renewal Application
ML14014A276
Person / Time
Site: Indian Point  Entergy icon.png
Issue date: 01/02/2014
From: Dacimo F
Entergy Nuclear Northeast
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NL-14-002
Download: ML14014A276 (7)


Text

4Entergy Enteray Nuclear Northeast Indian Point Energy Center 450 Broadway, GSB P.O. Box 249 Buchanan, NY 10511-0249 Tel (914) 254-2055 Fred Dacimo Vice President Operations License Renewal NL-14-002 January 02, 2014 U.S. Nuclear Regulatory Commission Document Control Desk 11545 Rockville Pike, TWFN-2 F1 Rockville, MD 20852-2738

SUBJECT:

REFERENCE:

Reply to Request for Additional Information Regarding the License Renewal Application Indian Point Nuclear Generating Unit Nos. 2 and 3 Docket Nos. 50-247 and 50-286 License Nos. DPR-26 and DPR-64 NRC letter, "Request for Additional Information for the Review of the Indian Point Nuclear Generating Unit Nos. 2 and 3, License Renewal Application Environmental Review (TAC NOS. MD5411 and MD5412)" dated November 22, 2013

Dear Sir or Madam:

Entergy Nuclear Operations, Inc is providing, in the attachment and the enclosed compact disk, the additional information requested in the referenced letter pertaining to NRC review of the License Renewal Application (LRA) for Indian Point 2 and Indian Point 3.

There are no new regulatory commitments in this submittal.

If you have any questions, or require additional information, please contact Mr. Robert Walpole at 914-254-6710.

I declarq unoier penalty of perjury that the foregoing is true and correct. Executed on 2014.

NL-14-002 Docket Nos. 50-247 and 50-286 Page 2 of 2

Attachment:

Reply to NRC Request for Additional Information Regarding the License Renewal Application

Enclosure:

Compact Disk Containing the SAMA Engineering Project Cost Estimates Prepared by RCM Technologies cc:

Mr. William Dean, Regional Administrator, NRC Region I (w/o enclosure)

Mr. Sherwin E. Turk, NRC Office of General Counsel, Special Counsel (w/o enclosure)

Mr. Dave Wrona, NRC Branch Chief, Engineering Review Branch I (w/o enclosure)

Ms. Lois James, NRC Environmental Project Manager (w/o enclosure)

Ms. Kimberly Green, NRC Sr. Project Manager, Division of License Renewal (w/o enclosure)

Mr. Douglas Pickett, NRR Senior Project Manager (w/o enclosure)

Ms. Bridget Frymire, New York State Department of Public Service (w/o enclosure)

NRC Resident Inspector's Office (w/o enclosure)

Mr. Francis J. Murray, Jr., President and CEO NYSERDA (w/o enclosure)

ATTACHMENT 1 TO NL-14-002 REPLY TO NRC REQUEST FOR ADDITIONAL INFORMATION REGARDING THE LICENSE RENEWAL APPLICATION ENTERGY NUCLEAR OPERATIONS, INC.

INDIAN POINT NUCLEAR GENERATING UNIT Nos. 2 and 3 DOCKET NOS. 50-247 and 50-286

Docket Nos. 50-247 & 50-286 NL-14-002 Page 1 of 4 INDIAN POINT NUCLEAR GENERATING UNIT NOS. 2 AND 3 LICENSE RENEWAL APPLICATION (LRA)

REQUEST FOR ADDITIONAL INFORMATION (RAI)

NRC RAI Your May 6, 2013, letter to the NRC states:

"The completed SAMA engineering project cost estimates were prepared by RCM Technologies for Entergy in accordance with sound engineering practices and have been reviewed and approved by Entergy management."

Please provide the RCM Technologies report and cost estimates, including definitions of the cost breakdowns:

(1) Entergy engineering support, including study, design, and project management; (2) Contract engineering support, including field engineers and planners; (3) Materials and equipment; (4) Plant craft labor; (5) Other Entergy support, including Quality Control, Training, and Operations Department; and (6) Other contract support, including security, health physics, and radwaste processing and storage.

Response to RAI As noted in the Request for Additional Information (RAI), on May 6, 2013 Entergy submitted to the NRC the results of completed engineering project cost estimates for severe accident mitigation alternatives (SAMAs) previously identified as potentially cost-beneficial for Indian Point Nuclear Generating Units 2 and 3 (IPEC). On May 17, 2013, the engineering project cost estimates were produced to both New York State and the NRC as part of the ongoing mandatory disclosure process in the IPEC license renewal proceeding. The completed SAMA engineering project cost estimates were prepared by RCM Technologies for Entergy and as discussed further below the format and level of detail of the SAMA cost estimates are consistent with other engineering project cost estimates prepared for purposes of Entergy capital project funding. RCM prepared a separate engineering project cost estimate for each of the twenty-two potentially cost beneficial SAMAs. A copy of each SAMA cost estimate is included on the enclosed CD. There is no separate RCM Technologies report.

The requested definitions of the cost breakdowns are as follows.

(1) Entergy engineering support, including study, design, and project management Study:

Entergy has three general phases of an engineering project, study, design, and implementation. The first phase, study, is used to prepare preliminary design and

Docket Nos. 50-247 & 50-286 NL-14-002 Page 2 of 4 implementation estimates, and usually advances after initial funds have been authorized.

Studies generally are performed prior to the development of detailed designs, and prior to final management approval of design and implementation of the project.

Design:

The design phase is the development of the detailed design including drawings, bill of materials, procurement specification, procedures, computer models, databases and configuration control updates, in adequate detail to implement the project. It provides details associated with, but not limited to:

Conditions such as pressure, flow, temperature, fluid chemistry, and voltage/current Material aging and qualifications Instrumentation Environmental conditions from internal and external events including seismic and flooding Plant discharges Plant security Fire protection Radiation protection and controls HVAC Codes, standards and regulatory requirements Project Mana-gement:

Project management provides monitoring and control of the project to ensure it safely achieves the project deliverables within the approved scope, cost and schedule. These responsibilities include, but are not limited to:

Project goals and objectives Funding justifications Identifying the required support areas for design and implementation of the project team Facilitating meetings Development of the project plan Assure overall development of the study, design, and implementation phase estimates and the review, and approval, of the estimates Monitoring performance of the project against the project controls Ensuring completion of project closeout activities Approving project related contracts or revisions

Docket Nos. 50-247 & 50-286 NL-14-002 Page 3 of 4 (2) Contract engineering support, including field engineers and planners Contract engineering support may be required during periods when in-house staff either is resource constrained or lack the expertise to perform the necessary engineering.

Examples include projects such as turbine overhaul, HVAC, steam fitting, and high voltage installations. Under the oversight of Entergy design engineering or project management, the contract field engineer would resolve installation anomalies and design discrepancies.

They would work with installers and in-house engineering to revise the design as needed.

Contract planners would sequence the final design and create a step-by-step installation plan, including obtaining material, quality assurance hold points, manpower requirements, ensure return-to-service final testing is complete, etc.

(3) Materials and equipment Materials and equipment refer to the various components required to install an engineering change, such as transmitters, piping, heat exchangers, cables, pumps, etc. The components must be specified in a bill of materials for each new engineering change at the beginning of the design. The bill of materials facilitates the purchase of long lead time items, facilitates installation, configuration control, identification of spare parts, and cost estimating of the project.

(4) Plant craft labor Plant craft labor generally refers to in-house labor forces such as pipefitters, electricians, welders, labors, carpenters, etc.

(5) Other Entergy support, including quality control, training, and operations department During the development of an engineering change, various departments must participate to ensure the change is of the highest quality and meets the intent and needs of the facility, specifically:

Quality control measures are applied as required by 1 OCFR50 Appendix B by performing independent assessments during the design and implementation stages Training may be required depending on the nature of the engineering change. As examples, there may be a change in the operation of a system, structure, or component (SSC) requiring training to ensure the SSC is operated correctly. The SSC may be different than other SSCs in the plant requiring training for the affected departments Operations department participation is essential in the engineering change to ensure their needs are met, including identification of operating procedure changes, simulator changes, and, as stated above, training on the affected equipment

Docket Nos. 50-247 & 50-286 NL-14-002 Page 4 of 4 (6) Other contract support, including security, health physics, and radwaste processing and storage Other contract support may be required during periods when in-house staff either is resource constrained or lacks the expertise to implement the engineering change. For example, an engineering change that could impact the security system requires a review by security personnel. Review of the security system can only be performed by individuals who have been qualified to review safeguards materials. The review would consider vital areas, barrier breaches, proximity to fences, security doors, lighting, communications, etc. During implementation of the engineering change, additional health physics technicians may be needed to support the work scope. In addition, radioactive waste may be generated requiring storage and processing for shipment to off-site facilities, thereby incurring additional project costs.