Text

UNITED STATES NUCLEAR REGULATORY COMMISSION REGION III 2443 WARRENVILLE ROAD, SUITE 210 LISLE, IL 60532-4352 December 17, 2013 Mr. Michael J. Pacilio Senior Vice President, Exelon Generation Company, LLC President and Chief Nuclear Officer (CNO), Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555

SUBJECT:

DRESDEN UNIT 1 MASTER INSPECTION PLAN CALENDAR YEAR 2014

Dear Mr. Pacilio:

In accordance with U.S. Nuclear Regulatory Commission (NRC) Inspection Manual Chapter (IMC) 2561, Decommissioning Power Reactor Inspection Program, the NRC Region III staff developed a Master Inspection Plan (MIP) for Dresden Unit 1 for calendar year 2014. The inspection plan is based on current Unit 1 performance and the decommissioning activities planned for the site from January through December 2014. The plan outlines how we intend to focus regional inspection resources to provide oversight of decommissioning activities.

The MIP is based, in part, on your proposed schedule of decommissioning activities for calendar year 2014. As a result, the plan and the focus of NRC inspection resources may change to reflect those activities or your performance. In order to ensure that the MIP remains current, we request that you keep the Materials Control, ISFSI, and Decommissioning Branch (MCID) staff informed of any significant changes in your proposed schedule of decommissioning activities.

You will be informed of any changes to our plans for inspections of Dresden Unit -1.

We currently plan to conduct one or two inspections at Dresden Unit 1 during calendar year 2014. The inspection(s) will focus on your self-assessment and corrective action program, radiological controls, radioactive waste processing and other activities related to SAFSTOR. In particular, we anticipate an onsite inspection to coincide with the demolition of Unit-1 outdoor waste storage tanks currently planned for spring 2014. The inspection procedures we plan to utilize for the inspections are as follows:

Inspection Procedure Title IP 37801 Safety Reviews, Design Changes and Modifications IP 40801 Self-Assessment, Auditing and Corrective Action IP 71801 Decommissioning Performance and Status Review IP 83750 Occupational Radiation Exposure IP 84750 Radioactive Waste Treatment, Effluent and Environmental Monitoring

In accordance with Title 10 of the Code of Federal Regulations (CFR) 2.390 of the NRCs Rules of Practice, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the NRC's Agencywide Documents Access and Management system (ADAMS), accessible from the NRCs website at http://www.nrc.gov/reading-rm/adams.html.

We will gladly discuss any questions you may have regarding this MIP. If you have questions, please direct them to Mr. Wayne Slawinski at (630) 829-9820.

Sincerely,

/RA/

Robert J. Orlikowski, Chief Materials Control, ISFSI, and Decommissioning Branch Division of Nuclear Materials Safety Docket No. 050-00010 License No. DPR-2 cc:

Distribution via ListServ

In accordance with Title 10 of the Code of Federal Regulations (CFR) 2.390 of the NRCs Rules of Practice, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the NRC's Agencywide Documents Access and Management system (ADAMS), accessible from the NRCs website at http://www.nrc.gov/reading-rm/adams.html.

We will gladly discuss any questions you may have regarding this MIP. If you have questions, please direct them to Mr. Wayne Slawinski at (630) 829-9820.

Sincerely,

/RA/

Robert J. Orlikowski, Chief Materials Control, ISFSI, and Decommissioning Branch Division of Nuclear Materials Safety Docket No. 050-00010 License No. DPR-2 cc:

Distribution via ListServ DISTRIBUTION:

Bruce Watson John Hickman Patricia Pelke Pat Louden AnnMarie Stone Greg Roach Alan Barker Harral Logaras Carole Ariano Linda Linn Tammy Tomczak MCID Branch ADAMS Accession Number :

DOCUMENT NAME: G:\\DNMSIII\\Work in progress\\MIP -Dresden Unit 1 2014 MIP.docx Publicly Available Non-Publicly Available Sensitive Non-Sensitive To receive a copy of this document, indicate in the concurrence box "C" = Copy without attach/encl "E" = Copy with attach/encl N" = No copy OFFICE RIII DNMS RIII DNMS RIII C RIII NAME WJSlawinski:ps*WJS RJOrlikowski*RJO DATE 12/19/13 12/17/13 OFFICIAL RECORD COPY