NRR E-mail Capture - Palisades - Request for Additional Information - Reactor Vessel Internals - ME9569 - Email Resend
ML13346A644
Person / Time
Site: Palisades 
Issue date: 12/12/2013
From: Mahesh Chawla
Division of Operating Reactor Licensing
To: Erickson J
Entergy Nuclear Palisades
References
ME9569
Download: ML13346A644 (3)


Text

1 NRR-PMDAPEm Resource From:

Chawla, Mahesh Sent:

Thursday, December 12, 2013 10:38 AM To:

ERICKSON, JEFFREY S (JERICKS@entergy.com); MIKSA, JAMES P (jmiksa@entergy.com)

Cc:

Rosenberg, Stacey; Poehler, Jeffrey; Cheruvenki, Ganesh; Purtscher, Patrick; Jenkins, Joel; Taylor, Thomas; Scarbeary, April; Benjamin, Jamie

Subject:

Palisades - Request for Additional Information - REACTOR VESSEL INTERNALS - ME9569 -

Email Resend

( I am resending this email due to minor corrections. Please disregard the first email on this subject.)

By letter dated September 13, 2012 (ADAMS Accession No. ML12257A352), supplemented by letter dated April 4, 2013 (ADAMS Accession No. ML13094A414), Entergy Nuclear Operations, Inc. (ENO) submitted an aging management program (AMP) for the Palisades Nuclear Plant (Palisades) reactor vessel internals (RVI).

The NRCs Vessels and Internals Integrity Branch is in the process of reviewing the Palisades AMP report, and based on the review conducted thus far, the staff has developed a second request for additional information (RAI) as addressed in the enclosure. The MRP-227-A report, Pressurized Water Reactor Internals Inspection and Evaluation Guidelines, and its supporting reports were used as technical bases for developing the subject AMP. This second request is based on the ongoing review of information regarding the generic applicability of the MRP-227-A report and its associated technical basis. Please provide your response to the following request on docket within 30 days of the receipt of this email. In case of any further clarification needed, please arrange a teleconference with the NRC staff and invite the folks on cc. Thanks REACTOR VESSEL INTERNALS AT PALISADES NUCLEAR PLANT DOCKET NO. 50-255 (TAC NO. ME9569)

RAI-2-1:

As discussed in References 1 and 2, the staff has identified two additional questions that all CE and Westinghouse design plants referencing topical report MRP-227-A must answer to close Applicant/Licensee Action Item 1 related to plant-specific applicability of the topical report. If the answer to either or both questions is yes, then further evaluation will be necessary to demonstrate the applicability of MRP-227-A to Palisades.

The staff therefore requests the following information:

1. Do the Palisades RVI have non-weld or bolting austenitic stainless steel components with 20% cold work or greater, and if so do the affected components have operating stresses greater than 30 ksi?
2. Has Palisades ever utilized atypical design or fuel management that could make the assumptions of MRP-227-A regarding core loading/core design non-representative for that plant, including power changes/uprates?

References

1. 2/25/2013 Summary of Telecom with EPRI and Westinghouse Electric Company, March 15, 2013 (ADAMS Accession No. ML13067A262)
2. MRP-227-A Applicability Guidelines for Combustion Engineering and Westinghouse Pressurized Water Reactor Designs, Enclosure to MRP Letter 2013-025, October 14, 2013

2 Mahesh Chawla Project Manager Phone: 301-415-8371 Fax: 301-415-1222 mahesh.chawla@nrc.gov

Hearing Identifier:

NRR_PMDA Email Number:

952 Mail Envelope Properties (Mahesh.Chawla@nrc.gov20131212103800)

Subject:

Palisades - Request for Additional Information - REACTOR VESSEL INTERNALS - ME9569 - Email Resend Sent Date:

12/12/2013 10:38:21 AM Received Date:

12/12/2013 10:38:00 AM From:

Chawla, Mahesh Created By:

Mahesh.Chawla@nrc.gov Recipients:

"Rosenberg, Stacey" <Stacey.Rosenberg@nrc.gov>

Tracking Status: None "Poehler, Jeffrey" <Jeffrey.Poehler@nrc.gov>

Tracking Status: None "Cheruvenki, Ganesh" <Ganesh.Cheruvenki@nrc.gov>

Tracking Status: None "Purtscher, Patrick" <Patrick.Purtscher@nrc.gov>

Tracking Status: None "Jenkins, Joel" <Joel.Jenkins@nrc.gov>

Tracking Status: None "Taylor, Thomas" <Thomas.Taylor@nrc.gov>

Tracking Status: None "Scarbeary, April" <April.Scarbeary@nrc.gov>

Tracking Status: None "Benjamin, Jamie" <Jamie.Benjamin@nrc.gov>

Tracking Status: None "ERICKSON, JEFFREY S (JERICKS@entergy.com)" <JERICKS@entergy.com>

Tracking Status: None "MIKSA, JAMES P (jmiksa@entergy.com)" <jmiksa@entergy.com>

Tracking Status: None Post Office:

Files Size Date & Time MESSAGE 2756 12/12/2013 10:38:00 AM Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received: