Registration of Use of Cask to Store Spent Fuel
ML13345A613
Person / Time
Site: Holtec, Browns Ferry  Tennessee Valley Authority icon.png
Issue date: 12/09/2013
From: Polson K
Tennessee Valley Authority
To:
Document Control Desk, NRC/NMSS/SFST
References
Download: ML13345A613 (2)


Text

Tennessee Valley Authority, Post Office Box 2000, Decatur, Alabama 35609-2000 December 9, 2013 10 CFR 72.4 10 CFR 72.212 ATTN: Document Control Desk Director, Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Browns Ferry Nuclear Plant, Units 1, 2, and 3 Renewed Facility Operating License Nos. DPR-33, DPR-52, and DPR-68 NRC Docket Nos. 50-259, 50-260, 50-296, and 72-052

Subject:

Registration of Use of Cask to Store Spent Fuel In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 72.212, "Conditions of General License Issued Under §72.210," paragraph (b)(2), the Tennessee Valley Authority (TVA) is submitting the registration for the use of a spent fuel storage cask under the general license to store spent fuel at the Browns Ferry Nuclear Plant (BFN) Independent Spent Fuel Storage Installation. The initial use of the cask listed below, to store spent fuel, occurred on November 9, 2013. This registration is required to be submitted within 30 days of initial use.

Accordingly, this registration is due by December 9, 2013.

Pursuant to 10 CFR 72.212(b)(2), TVA is providing the following cask loading information:

Licensee Name:

Tennessee Valley Authority Licensee Address:

Post Office Box 2000 1

Decatur, Alabama 35609-2000 Reactor License Numbers:

DPR-33, DPR-52, and DPR-68 Reactor Docket Numbers:

50-259, 50-260, 50-296 Responsible Individual:

Jamie L. Paul Site Licensing Manager, Browns Ferry Nuclear Plant

U.S. Nuclear Regulatory Commission Page 2 December 9, 2013 Cask Certificate Number:

1014, Amendment 5 Cask Model Number:

Holtec International, HI-STORM 100S For the cask system placed in service on November 9, 2013:

Cask Identification Multi-Purpose Canister Numbers Type 68, Serial No. 0329 Overpack Serial No. 0494 There are no new regulatory commitments contained in this letter. Should you have any questions concerning this submittal, please contact J. L. Paul, Nuclear Site Licensing Manager, at (256) 729-2636.

Respectfully, K. J. Poison Vice President cc: NRC Regional Administrator - Region II