Similar Documents at Perry |
---|
Category:Deficiency Report (per 10CFR50.55e and Part 21)
MONTHYEARML23241A0022023-08-25025 August 2023 Paragon Final Part 21 Report on Defect with Eaton/Cutler Hammer Size 4 and 5 Freedom Series Contactors Modified by Paragon with Special Coils And/Or with RTV to Improve the Securing of Shading Coils ML23221A3702023-08-0303 August 2023 Paragon Energy Solutions, 10CFR Part 21 Initial Notification: P21-08032023-IN, Rev. 0 ML23038A0192023-02-0606 February 2023 Curtiss-Wright Part 21 Notification for Qualtech Np Supplied Eaton TMR5 Timing Relays ML22341A0322022-11-30030 November 2022 10 CFR Part 21 Notification from Curtiss-Wright Nuclear Division for Qualtech Np Supplied Eaton TRM5 Timing Relays ML21168A2172021-06-17017 June 2021 GE Hitachi Nuclear Energy Americas, LLC - 10 CFR Part 21.21(d)-Reportable Condition: Fuel Support Side Entry Orifice Meta-Stable Flow for 2 Beam Locations in the BWR/6 Reactors M210077, GE Hitachi Nuclear Energy Americas, LLC - 10 CFR Part 21.21(d)-Reportable Condition: Fuel Support Side Entry Orifice Meta-Stable Flow for 2 Beam Locations in the BWR/6 Reactors2021-06-17017 June 2021 GE Hitachi Nuclear Energy Americas, LLC - 10 CFR Part 21.21(d)-Reportable Condition: Fuel Support Side Entry Orifice Meta-Stable Flow for 2 Beam Locations in the BWR/6 Reactors ML20366A0482020-12-0707 December 2020 10CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc. Report No. 10 CFR21-0114, Rev. 1 ML20366A0472020-11-18018 November 2020 Curtiss-Wright 10 CFR Part 21 Notification for SF-1154 Hydraulic Fluid Batch 17BLVS293 M200087, GE-Hitachi Nuclear Energy Americas, LLC - 10 CFR Part 21.21(d)-Reportable Condition: Non-Conservative BWR/6 Side Entry Orifice (SEO) Loss Coefficients2020-06-24024 June 2020 GE-Hitachi Nuclear Energy Americas, LLC - 10 CFR Part 21.21(d)-Reportable Condition: Non-Conservative BWR/6 Side Entry Orifice (SEO) Loss Coefficients ML20176A4322020-06-24024 June 2020 GE-Hitachi Nuclear Energy Americas, LLC - 10 CFR Part 21.21(d)-Reportable Condition: Non-Conservative BWR/6 Side Entry Orifice (SEO) Loss Coefficients ML20049A0752020-02-11011 February 2020 C&D Technologies, Inc. -10 CFR Part 21 Evaluation Regarding Container Failure in KCR-07 Batteries ML19121A1552019-04-15015 April 2019 Curtiss-Wright Nuclear Division, Enertech - 10 CFR Part 21 Notification for SF-1154 Hydraulic Fluid ML17194A8252017-07-11011 July 2017 Part 21 Report Re Wedge Pin Failure in Anchor Darling Motor Operated Double Disc Gate Valves with Threaded Stem to Upper Wedge Connections ML17090A3982017-03-27027 March 2017 Engine Systems, Inc. - Part 21 Report Regarding Identification of Failed Diode Surge Suppressor with Internal Manufacturing Defect ML17081A4532017-03-20020 March 2017 Part 21 - Plastic Jar Dedication Sampling ML17055C1772017-02-0909 February 2017 10 CFR 21 Evaluation Regarding Design Basis Calculation Error Using FL0-2D Software ML17026A4142017-01-20020 January 2017 C&D Technologies, Inc. - Part 21 - Plastic Jar Dedication Sampling ML17032A0802016-12-30030 December 2016 Engine Systems, Inc., 10CFR21 Reporting of Defects and Non-Compliance, Report No. 10CFR21-0114, Rev. 0 ML17006A0102016-12-29029 December 2016 Engine Systems, Inc. - Part 21 Issues Identified with the Enterprise Diesel Engine Subcover ML17006A0142016-12-13013 December 2016 Enercon - Part 21 - Notification-Design Basis Errors Using Flo-2D Software ML16342A9812016-11-23023 November 2016 Enercon - Part 21 Notification - Design Basis Errors Using FLO-2D Software ML16251A0982016-09-0202 September 2016 Part 21 - Potential Failure of Battery System Connections ML16252A2742016-08-29029 August 2016 Azz/Nli - Part 21 Report - Potential Allen Bradley Timing Relay ML16243A4742016-08-26026 August 2016 Potential Part 21 Unqualified Component in Certain Allen Bradley Timing Relays ML16232A6042016-08-15015 August 2016 Potentially Unqualified Component in Certain Allen Bradley Timing Relays ML16238A1862016-08-15015 August 2016 Update - Report of Potential l0CFR Part 21, Allen Bradley Timing Relay Model 700RTC-NRC Event Number 51030, Accession Number ML15134A016 ML16188A3742016-06-30030 June 2016 Part 21 - Inadequate Swaging and Adherence of Silicone O-Ring and Silicone PAD Soft Seat Main Disc and Pilot Disc Assemblies ML16154A2072016-05-26026 May 2016 Part 21, Azz/Nli Nuclear Logistics, Inc., Potentially Unqualified Component in Certain Allen Bradley Timing Relays Model 700RTC ML16111A4202016-04-0808 April 2016 Part 21 Report No. P21-04302015, Rev. 1 Regarding Potentially Unqualified Component in Certain Allen Bradley Timing Relays, Per Browns Ferry, Ginna, Millstone, Nine Mile Point, North Anna, Ft. Calhoun, Perry, River Bend, South Texas Project ML16098A4462016-03-22022 March 2016 United Controls International - Part 21 Report Regarding Defective Fuses, Per Perry Nuclear Power Plant ML15217A3032015-08-0404 August 2015 Notification of Part 21 - Report - Ferraz Shawmut/Mersen Fuses P/N: AJT25 and AJT60 ML15140A2182015-05-11011 May 2015 Part 21 Report Regarding Defect Identified 6 Inch Gear Operated Ball Valves (Part Number GBV-B2-60-0020 & GBV-B2-60-0112), Notification No. 15-1 ML15134A0162015-05-0101 May 2015 Part 21 Report Regarding Potentially Unqualified Component in Certain Allen Bradley Timing Relays ML15159A5682015-04-30030 April 2015 Report of Potential 10CFR Part 21, Allen Bradley Timing Relay Model 700RTC ML15022A6502015-01-20020 January 2015 Letter from Steven R. Eisenberg USNRC 10CFR Part 21 Notification ML14274A0522014-09-22022 September 2014 Final Report 10CFR Part 21 Evaluation Regarding Misaligned Separators in LCR-25 Standby Batteries, Revision 1 - Original Letter Did Not Include the List of Affected Utilities ML14204A7072014-07-23023 July 2014 Completed Evaluation of Part 21 Potentially Reportable Condition Notification: Unseating of Valve Spring on SSPV ML14204A7082014-07-23023 July 2014 Enclosure 2, Description of Closure Evaluation, Non-Proprietary Information - Class I (Public) ML14210A0102014-07-23023 July 2014 Part 21 - Unseating of Valve Spring on Scram Solenoid Pilot Valve ML14134A0792014-05-0808 May 2014 Part 21 - Potential Defect in NUS-710DU Trip Unit to Produce a Valid Trip Output Signal ML14139A2592014-05-0808 May 2014 10 CFR Part 21 Report Notification, NUS710DU Trip Units ML13324A3912013-11-0808 November 2013 Part 21 - Machining Error Identified in Geared Limit Switches ML13284A0842013-10-0303 October 2013 Deficiency Report from Baldor Electric Co., on Nuclear Nonconformance Event No. 49302 ML13165A3422013-06-12012 June 2013 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers ML13064A0122013-02-25025 February 2013 Notification of Potential Part 21 Report Re Wedge Pin Failure of an Anchor/Darling Double-Disc Gate Valve ML13044A0752013-02-0808 February 2013 Part 21 - Completed Evaluation for Potential Error in Main Steam Line High Flow Calculational Methodology ML13042A0962013-02-0808 February 2013 Completed Evaluation of Part 21 Potentially Reportable Condition Notification: Error in Main Steam Line High Flow Calculational Methodology ML12348A1362012-12-13013 December 2012 Part 21 60-Day Interim Report Notification: Adequacy of Design Change in Am Magne-Blast Circuit Breakers ML12352A1232012-12-13013 December 2012 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers ML12347A3082012-12-12012 December 2012 Part 21 60-Day Interim Report Notification: Error in Main Steam Line High Flow Calculational Methodology 2023-08-03
[Table view] |
Text
-i 11/08/2013 U.S. NuclearRegulatory Commission Operations Center Event Report Pane I Part 21 (PAR) Event# 49522 Rep Org: FLOWSERVE Notification Date / Time: 11/08/2013 16:26 (EST)
Supplier: LIMITORQUE Event Date / Time: 09/04/2013 (EST)
Last Modification: 11/08/2013 Region: 1 Docket #:
City: LYNCHBURG Agreement State: Yes County: License #:
State: VA NRC Notified by: JEFF MCCONKEY Notifications: ALAN BLAMEY R2DO HQ Ops Officer: DONG HWA PARK CHRISTINE LIPA R3DO Emergency Class: NON EMERGENCY PART 21 GROUP EMAIL 10 CFR Section:
21.21 (d)(3)(i) DEFECTS AND NONCOMPLIANCE PART 21 - MACHINING ERROR IDENTIFIED IN GEARED LIMIT SWITCHES The following is a summary of information received from Flowserve via facsimile:
"On September 4, 2013, in-house inspection of Limitorque SMB Geared Limit Switch (GLS) cartridges revealed a machining error in a subcomponent used in the GLS. The deviation was caused by a dimensional error concerning the location of a drilled hole in a drive pinion shaft. This error results in a reduction of gear tooth engagement inside the GLS which could potentially reduce the service life of the GLS causing a loss of function. To date, Limitorque's investigation of this machining error has not shown this deviation to be significant enough to affect the safety related function of the GLS. However, Limitorque has requested all switches certified for nuclear safety related service which were manufactured in the designated time frame be returned for inspection and replacement as needed."
The components were sent to Perry Nuclear Generating Station.
o!
11/08/2013 U.S. NuclearRegulatory Commission OperationsCenter Event Report Page 1 Part 21 (PAR) Event# 49522
.4345229831 04:19:02 p.m. 11-08-2013 1 /3 Flowserve 5114 Woodall Road Lynchburg, VA. 24502 Flowserve To: NRC Operations Center Fax: (301) 816-5151 From: JeffMcConkey Date: 11/8/2013 Re: Pages: 3 including this cover sheet EZ Urgent El For Review 0 Please Comment 0 Please Reply 0 Please Recyde Notes: Limitorque Part 21 Notification Final Report Potential Defect in SMB Geared Limit Switch.
Thank You Jeff McConkey Quality Assurance Manager Flowserve Corporation - FCD Lynchburg 5114 Woodall Road Lynchburg, VA 24506 (office) 434-845-9738 (cell) 434-851-4402 jmcconkey@flowserve.com
4345229831 04:19:33 p.m. 11-08-2013 2/3 FLOWSERVE
- Flow Control Division Limitorque Lntru November 8, 2013 To: U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 Attention: NRC Operations Center, Fax # 301-816-5151 From: Flowserve Corporation Limitorque 5114 Woodall Road Lynchburg VA 24506
Subject:
Limitorque Part 21 Notification Report Potential Defect in SMB Geared Limit Switch
Description:
On September 4, 2013, in-house inspection of Limitorque SMB Geared Limit Switch (GLS) cartridges revealed a machining error in a subcomponent used in the GLS. The deviation was caused by a dimensional error concerning the location of a drilled hole in a drive pinion shaft. This error results in a reduction of gear tooth engagement inside the GLS which could potentially reduce the service life of the GLS causing a loss of function. To date, Limitorque's investigation of this machining error has not shown this deviation to be significant enough to affect the safety related function of the GLS.
However, Limitorque has requested all switches certified for nuclear safety related service which were manufactured in the designated time frame be returned for inspection and replacement as needed.
Components Affected:
SMB/SB/SBD Geared Limit Switch (GLS) assemblies manufactured between August 12, 2013 and September 4, 2013 were potentially affected.
GLS assemblies which were built and shipped during this time frame are limited to the two orders identified below. The customers listed below have been notified.
Limitorque Order No: 132845.005 Customer: Areva Nuclear Parts Center Customer P.O. #: 1013031247 Identifier: 2-train GLS, Part # 10153 Quantity Affected: 11 Location of Components Qty (8) have been returned to Limitorque.
Qty (3) were shipped to OPG. At Limitorques request, Areva NP contacted OPG and the GLS assemblies have been returned for replacement.
Page 1 of 2
4345229831 04:20:40 p.m. 11-08-2013 3/3 Flow Control Division FLOWSERVE Limitorque Limitorque Order No: 12923 1.001 Customer: Flowserve FCD - Raleigh, NC Customer P.O. #: 201936 Identifier: 2-train GLS Part # 10144 installed in SMB-000 / HBC-0 actuators Quantity Affected: 3 (Actuator Serial #s: 998306, 998307, 998308)
Location of Components Actuators were shipped to FENOC, Perry NGS (Reference Perry P.O. #
454003386). Replacement of the GLS assemblies is in process. The MOVs have not been installed in the plant.
Cause and Corrective Action:
Limitorque QA investigation traced the potentially effected components to a single lot of drive pinions that was placed into Limitorque stock on August 12, 2013. Immediate corrective action involved 100% inspection of all drive pinions in stock. In addition, the drive pinions already installed in GLS assemblies in stock were inspected for the deviation. Limitorque has determined the cause of this machining deviation to be improper use of the drilling operation machining fixture for this component. An improved machining fixture for this subcomponent part has been designed and will be in place by Nov 30, 2013.
Technical questions related to the notification can be addressed to Kyle Ramsey, Chief Mechanical Engineer, Flowserve - Limitorque (kramsey@,lowserve.com)
Submitted By:________________
Jeff McConkey, Quality Assurance Manager, Flowserve - Limitorque 5114 Woodall Rd, Lynchburg VA 434-845-9738 jmcconkey@,Flowserve.com Page 2 of 2