LONG ISLAND LIGHTING COMPANY SHOREHAM NUCLEAR POWER STATION P.O. BOX 618, NORTH COUNTRY ROAD

  • WADING RIVER, N.Y. 11792 Direct Dial Number April 16, 1984 TDI-15 Mr. H. R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555

Dear Mr. Denton:

Please find enclosed fifteen (15) copies of the TDI Diesel Generator Report on Engine Driven Jacket Water Pump Design Review. An additional five (5) copies of the report are being forwarded to Battelle Pacific Northwest Laboratories, per NRC request, under cover of this letter.

This report has been prepared and is being submitted on behalf of the TDI Diesel Generator Owners' Group.

Should you have any questions, please do not hesitate to contact us.

Very truly yours, W. J. Museler Technical Program Director TDI Diesel Generator Owners' Group JTM:mp cc:

Owners' Group Executives Owners' Group Alternates C. Berlinger R. Caruso (15 enclosures)

Battelle Northwest (5 enclosures)

  • 401832 8404 6 "7

PDR.ADOC K 05000206 A-bV* W-i.

P/

closure 1 TRANSAMERICA DELAVAL, INC.

EMERGENCY DIESEL GENERATOR DISTRIBUTION Plant Docket Utility Shoreham 50-322 Long Island Lighting Grand Gulf 1, 2 50-416, 417 Middle South Energy San Onofre 1 50-206 Southern California Edison Rancho Seco 50-312 SMUD River Bend 50-458, 459 Gulf States Utilities Shearon Harris 1, 2 50-400, 401 Carolina Power and Light Catawba 1, 2 50-413, 414.

Duke Power Perry 1, 2 50-440, 441 Cleveland Electric Illuminating Bellefonte 1, 2 50-438, 439 TVA Comanche Peak 1, 2 50-445t 446 Texas Utilities Services Vogtle 1, 2 50-424, 425 Georgia Power Midland.1, 2 50-329, 330 Consumers Power WNP-1'

.507460 Washington Public Power