Text

2013 NRC WRITTEN EXAM SEATING ARRANGEMENT ROOM 106 4/16/2013

~-~

I I

I I

I l 1

r 1

Ro 1 r- -

I II I

I pyl.\\J~(<._

I I

I I SRO I

of\\1L t~5> [_j SRO 1 SRO I

~b~t-.~

U f\\ltJ S£1~

SRO I RO

¥' 18 :P-efo?.._

I Ml t-.\\N\\L\\L SRO SRO l="uu.. ei.t.

I..J)&\\~

Front of Classroom

Person Asking Time Question Asked V. Hawthorne 0915 B. Bauer 0940 C. Lubahn 1004 2013 IL T Exam Question Log 4/16/2013 Question Question Number 43 Are there any conditions present that result in a system start signal?

43 Same as above 45 Questioned the timing of the information in the stem, and the word "displaced".

Answer Re-read stem to the student. No additional information provided 0945 contacted NRC (B. Palagi) to discuss question. Requested providing clarification that the students are to assume no other conditions other than those in the stem when answering the question.

This information was provided to all applicants in writing on a "white board" in the examination room.

Re-read the stem to the student. No additional information was provided.

QF-0715, Rev. 1 (ACP 102.21)

NRC Exit Atten~nce DATE 'f/2>/J. 3 SUBJECT :f /....{) f)(qHA ~$e~c:ho~RC INSP. REPORT: ____

NAME ORG/DEPT TITLE 7r 'A Lo l T s~ ~rvt'so.-

1------------+-----1-----------~~~~--~~------

L----------..1..------'---------------------