ML13308A101

From kanterella
Jump to navigation Jump to search
Board Notification 82-10:forwarding Info Re Pressurized Thermal Shock of Reactor Vessels in C-E Designed NSSS During Recovery from Small Break LOCA W/Extended Loss of Feedwater
ML13308A101
Person / Time
Site: Palo Verde, Waterford, San Onofre, 05000000
Issue date: 03/18/1982
From: Tedesco R
Office of Nuclear Reactor Regulation
To:
Atomic Safety and Licensing Board Panel
Shared Package
ML13308A102 List:
References
REF-GTECI-A-49, REF-GTECI-RV, TASK-A-49-.13, TASK-AS, TASK-BN-82-10, TASK-OR BN--82-10, BN-82-10, NUDOCS 8204160037
Download: ML13308A101 (11)


Text

DISTRIBUTION Dockets (50-361/362 s

MARCH.181982 50-382 and 50-528/529/530)

NRC PDR NSIC L PDR TIC TERA MEMORANDUM FOR: The Atomic Safety and Licensing Appeal Board for San Onofre, Units 2 and 3 The Atomic Safety and Licensing Boards for Waterford Unit 3 The Atomic Safety and Licensing Boards for Palo Verde Units 1, 2, and 3

'e smo r

FROM:

Robert L. Tedesco, Assistant Director for Licensing, DL 5

SUBJECT:

INFORMATION ITEM - REPORT ENTITLED, "EVALUATION OF PRESSURIZED THERMAL SHOCK EFFECTS DUE TO SMALL BREAK LOCAs WITH LOSS OF FEEDWATER FOR THE COMBUSTION ENGINEERING NSSS" (Board Notification No. 82-10)

In accordance with present NRC procedures for Board Notifications, the enclosure is provided for your information.

The enclosed report addresses the subject of pressurized thermal shock of reactor vessels in Combustion Engineering designed Nuclear Steam Supply Systems during recovery from a small break loss of coolant accident with extended loss of feedwater. This report is of a generic nature and is not applicable to any individual licensee or applicant until the report is referenced by that licensee or applicant for use in his docket.

However, the enclosed Appendices H, I, and J to the report is an evaluation of pressurized thermal shock effects for San Onofre Units 2 and 3, Waterford Unit 3, and Palo Verde Units 1, 2, and 3. These appendices conclude that reactor vessel crack initiation would not occur for the transients considered for more than 32 effective full-power years.

"Original Signed By:

Robert L. Tedesco, Assistant Director for Licensing Division of Li-censing

Enclosures:

1. CEN-189, "Evaluation of Pressurized Thermal Shock Effects Due to Small Break LOCAs with Loss of Feedwater for the Combustion Engineering NSSS", December 1981 0
2. Appendix H to CEN-189 2
3. Appendix I to CEN-189 9CUM mlmma OR
4. Appendix J to CEN-189 OFFICE SURFNAME)

.b RL so DATE

__82_

3/4/2 NRC FORM 318 (10-80) NRCM 0240 OFFICIAL RECORD CO PY USGPO: 1981-335-960

DISTRIBUTION See Attached MEMORANDUM FOR:

e Atomic Safety and Licensing Appeal Board for an Onofre, Units 2 and 3 FROM:

Robe t L. Tedesco, Assistant Director fo Licensing Divis on of Licensing

SUBJECT:

INFORMA ION ITEM - REPORT ENTITLED, "EVALUATION OF PRESSURIZED THERMAL HOCK EFFECTS DUE TO SMALL BREAK LOCAs WITH LOSS OF FEEDWATE FOR THE COMBUSTION ENGINEERING NSSS" (Board No ification No. 82-10)

In accordance with present NR procedures for Board Notifications, the enclosure is provided for your informati n.

The enclosed report addresses th subject of pressurized thermal shock of reactor vesseis in Combustion Engineering esigned Nuclear Steam Supply Systems during recovery from a small break loss of coolant accident with extended loss of feedwater.

This report is of a gene rc nature and is not applicable to any individual licensee or applicant until the report is referenced by that licensee or applicant for use in his docket.

Hovever, the enclosed Appendix H to the report is an evaluation of pressurized t rmal shock effects for San Onofre Units 2 and 3. This appendix concludes th t reactor vessel crack initiation would not occur for the transients conside d for more than 32 effective full power years. We note that the San Onofre Un ts 2 and 3 operating licenses will expire on October 18, 2013, less than 32 cale ar years from now, at which time the plants will have operated for significantl less than 32 effective full power years.

Robert L. Tedesco Assistant Director for Licensing Division of Licensing

Enclosures:

1.

CEN-189, "Evaluation of Pressurized Thermal Shock Effects Due to Small Break LOCAs with Loss of Feedwater for the Combustion Engineering NSSS", December 1981

2. Appendix H to above report, "Evaluation of Pressurized Thermal Shock Effects Due to Small Break LOCAs with Loss of Feedwater for the San Onofre 2 and 3 Reactor Vessels" cc:

Service List

  • SEE PREVIOUS CONCURRENCE FOR INITIALS retyp&ICE.

DL: L*.DLe:L*...

f....

URNAME)

.1b...........

RL....edesco.....

DE 0 803/

/82 NRC FORM 318 (10-80) NRCM 0240 OFFICIAL RECORD COPY USGPO: 1981-335-960

DISTRIBUTION See Attached MEMORANDUM FOR: The Atomic Safety and Licensing Appeal Board for n Onofre, Units 2 and 3 FROM:

Robeht L. Tedesco, Assistant Director forLicensing Division of Licensing

SUBJECT:

INFORMATION ITEM - REPORT ENTITLED, "EVALUATION OF PRESSURIZED THERMAL SROCK EFFECTS DUE TO SMALL BREAK LOCAs WITH LOSS OF FEEDWATER FQR THE COMBUSTION ENGINEERING NSSS" (Board Notification No. 82-10)

In accordance with present NRC procedures for Board Notifications, the enclosure is provided for your information.

The enclosed report addresses the subject of pressurized thermal shock of reactor vessells in Combustion Engineering designed Nuclear Steam Supply Systems during recovery from a small break loss of coolant accident with extended loss of feedwater.

This report is of a generic nature and is not applicable to any individual licensee or applicant until the report is referenced by that licensee or applicant for use in Iiis "dbcket.

Robert L. Tedesco, Assistant Director for Licensing Division of Licensing

Enclosure:

Report entitled, "Evaluation of Pressurized Thermal Sho'ck Effects Due to Small Break LOCAs with Loss of Feedwater for the Combustion Engineering NSSS" cc:

See next page

  • SEE PREVIOUS CONCUR ENCE FOR INITIALS retyICEJ D: L*

DL: L*

DATE12.2.

.8/ 82 N T EC FO.M 318 ( 0...02 0F C A R C R C P.....-

NRC FORM 318 (10-80) NRCM 0240 OFF IC IAL RE CORDCeOPY USGPO: 1981-335-960

MEMORANDUM FOR:

The Atomic Safety and Licensing Appeal Board for San Onofre, Units 2 and 3 FROM:

Robert L. Tedesco, Assistant Director for Licensing Divi son of Licensing

SUBJECT:

INFORTION ITEM - REPORT ENTITLED, "EVALUATION OF PRESSURIZED THERMAL SHOCK EFFECTS DUE TO SMALL BREAK LOCAs WITH LOSS OF FEEDWATER FOR THE COMBUSTION ENGINEERING NSSS" (Board Notification No. 82-10)

In accordance with present NRC procedures for Board Notifications, the enclosure is provided for your information.

Robert'L. Tedesco, Assistant Director for Licensing Division of Licensing

Enclosure:

DISTRIBUTION Report entitled, "Evaluation of Pressurized Docket Thermal Shock Effects Due to Small Break

\\

NRC PDR LOCAs with Loss of Feedwater for the L PDR Combustion Engineering NSSS" TERA NSIC cc:

See next page TIC ACRS(16)

OI&E(3)

RTedesco DEisenhut/RPurple MWilliams

  • FMiraglia HRood JKerrigan OFFCE) DL:L OFFICE DL SURNAME)

.4..

02/0 /82 02/ /82 D A TE 02.................................

1...9 NRC FORM 318 (10-80) NRCM O240 OFFICIAL RECORD CO PY USGPO: 1981-335-960

DISTRIBUTION OF BOARD NOTIFICATION San Onofre ACRS Members Licensing Dr. Robert C. Axtmann oafy P and Mr. Myer Bender BoardPanelDr.

Max W. Carbon Atomic Safety and Licensing Mr. Jes.

Ebeo Appel Bord PnelMr.

Jesse C. Ebersole Appeal Board Panel Docketing and Service Section Mr. Harold Etherington A. S. Carstens Dr. William Kerr

.Eilperin, Esq.

Dr. Harold W. Lewis Stephn E.Dr.

J. Carson Mark Phyllis M. Gallagher, Esq.

Mr. WillamsM. Mahi DavidW. GlmanMr.

William M. Mathis David W. Gilman Dr. Dade W. Moeller Dr. Reginald L. Gotchy Dr. Dad oet Dr. Cadet H. Hand, Jr.

Dr. Mi S.et Mrs..Lyn Harris Hicks Dr. Milton S. Plesset Mrs. Elizabeth B. Johnson Dr. Paul

.h ay Dr. W. Reed Johnson Dr. Paul G. Shewmon Jame L.

el.leyEsq.Dr.

Chester P. Siess James L. Kelley, Esq.

Mr. David A. Ward Janice E. Kerr, Esq.

Charles R. Kocher Charles E. McClung, Jr., Esq.

David R. Pigott, Esq.

Alan R. Watts, Esq.

Richard J. Wharton, Esq.

Mr. Robert Dietch Vice President Southern California Edison Company 2244 Walnut Grove Avenue P. 0. Box 800 Rosemead, California 91770 Mr. D. W. Gilman Vice President -

Power Supply San Diego Gas & Electric Company 101 Ash Street P. 0. Box 1831 San Diego, California 92112 cc: Charles R. Kocher, Esq.

James A. Beoletto, Esq.

Southern California Edison Company 2244 Walnut Grove Avenue P. 0. Box 800 Rosemead, California 91770 Orrick, Herrington & Sutcliffe ATTN:

David R. Pigott, Esq.

600 Montgomery Street San Francisco, California 94111 Mr. George Caravalho City Manager City of San Clemente 100 Avenido Presidio San Clemehte, California 92672 Alan R. Watts, Esq.

Rourke & Woodruff Suite 1020 1055 North Main Street Santa Ana, California 92701 Lawrence Q. Garcia, Esq.

California Public Utilities Commission 5066 State Building San Francisco, California 94102 Mr. V. C. Hall Combustion Engineering, Incorporated 1000 Prospect Hill Road Windsor, Connecticut 06095

Mr. Robert Dietch

- 2 Mr. D.. Gilman cc:

Mr. P. Dragolovich Bechtel Power Corporation P. 0. Box 608,60, Terminal Annex Los Angeles, California 90060 Mr. Mark Medford Southern California Edison Company 2244 Walnut Grove Avenue P. 0. Box 800 Rosemead, California 91770 Henry Peters San Diego Gas & Electric Company P. 0. Box 1831 San Diego, California 92112 Ms. Lyn Harris Hicks Advocate for GUARD 3908 Calle Ariana San Clemente, California 92672 Richard J. Wharton, Esq.

University of San Diego School of Law Environmental Law Clinic San Diego, California 92110 Phyllis M. Gallagher, Esq.

Suite 222 1695 West Crescent Avenue Anaheim, California 92,701 Mr. A. S. Carstens 2071 Caminito Circulo Norte Mt. La Jolla, California 92037 Resident Inspector, San Onofre/NPS c/o U. S. Nuclear Regulatory Commission P. 0. Box 4329 San Clemente, California 92672 Charles E. McClung, Jr., Esq.

Attorney at Law 24012 Calle de la Plata Suite 330 Laguna Hills, California 92653

DISTRIBUTION OF BOARD NOTIFICATION (82-10)

Waterford (ASLB)

ACRS Members Atomic Safety and Licensing Dr. Robert C. Axtmann Board Panel Mr. Myer Bender Atomic Safety and Licensing Dr. Max W. Carbon Appeal Board Panel Mr. Jesse C. Ebersole Docketing and Service Section Mr. Harold Etherington E. Blake, Esq.

Dr. William Kerr Mr. Luke Fontana Dr. Harold W. Lewis Dr. Harry Foreman Dr. J. Carson Mark Mr. Stephen M. Irving, Esq.

Mr. William M. Mathis Mr. Lyman L. Jones, Jr.

Dr. Dade W. Moeller Dr. Walter H. Jordan Dr. David Okrent Mr. M. Stevenson Dr. Milton S. Plesset Sheldon J. Wolfe, Esq.

Mr. Jeremiah J. Ray Dr. Paul G. Shewmon Dr. Chester P. Siess Mr. David A. Ward

a,.e Mr. L. V. Maurin WATERFORD Vice President -

Nuclear Operations Louisiana Power'& Light Company 142 Delaronde Street New Orleans, Louisiana. 70174 W. Malcolm Stevenson, Esq.

Monroe & Lemann 1424 Whitney Building New Orleans, Louisiana 70130 Mr. E. Blake Shaw, Pittman, Potts arid Trowbridge 1800 M Street, N. W.

Washington, D.C.

20036 Mr. D. L. Aswell Vice President, Power Production Louisiana Power & Light Company 142 Delaronde Street New Orleans, Louisiana 70174 Mr. F. J. Drummond Project Manager - Nuclear Louisiana Power & Light Company 142 Delaronde Street New Orleans, Louisiana, 70174 Mr. D. B. Lester Production Engineer Louisiana Power & Light Company 142 Delaronde Street New Orleans, Louisiana 70174 Lyman L. Jones, Jr., Esq.

Gillespie & Jones P. 0. Box 9216 Metairie, Louisiana 70005 Luke Fontana, Esq.

824 Esplanade Ave.

New Orleans, Louisiana 70116 Stephen M. Irving, Esq.

535 North 6th Street Baton Rouge, Louisiana 70802 Resident Inspector/Waterford NPS P. 0. Box 822 Killona, Louisiana 70066 Dr. D. C. Gibbs Middle South Services, Inc.

P. 0. Box 61000 New Orleans, Louisiana 70161

DISTRIBUTION OF BOARD NOTIFICATION (82-10)

Palo Verde (ASLB)

ACRS Members Atomic Safety and Licensing Dr. Robert C. Axtmann Board Panel Mr. Myer Bender Atomic Safety and Licensing Dr. Max W. Carbon Appeal Board Panel Mr. Jesse C. Ebersole Docketing and Service $ection Mr. Harold Etherington Dr. Dixon Callihan Dr. William Kerr Dr. Richard F. Cole Dr. Harold W. Lewis Arthur C. Gehr, Esq.

Dr. J. Carson Mark Rand L. Greenfield Mr. William M. Mathis Ms. Lee Hourihan Dr. Dade W. Moeller Robert M. Lazo, Esq.

Dr. David Okrent Dr. Milton S. Plesset Mr. Jeremiah J. Ray Dr. Paul G. Shewmon Dr. Chester P. Siess Mr. David A. Ward

Mr. E. E. Van Brunt, Jr.

PALO VERDE Vice President - Nuclear Projects Arizona Public Service Company P. 0. Box 21666 Phoenix, Arizona 85036 cc: Arthur C. Gehr, Esq.

Snell & Wilmer 3100 Valley Center Phoenix, Arizona 85073 Charles S. Pierson Assistant Attorney General 200 State Capitol 1700 West Washington Phoenix, Arizona 85007 Charles R. Kocher, Esq., Assistant Counsel' James A. Beoletto, Esq.

Southern California Edison Company P. 0. Box 800 Rosemead, California 91770 Margaret Walker Deputy Director of Energy Programs Economic Planning and Development Office 1700 West Washington Phoenix, Arizona 85007 Mr.

Rand L. Greenfield Assistant Attorney General Bataan Memorial Building Santa Fe, New Mexico 87503 Resident Inspector Palo Verde/NPS U.S. Nuclear Regulatory Commission P. 0. Box 21324 Phoenix, Arizona 85001 Ms. Patricia Lee Hourihan 6413 S. 26th Street Phoenix, Arizona 85040