NPDES Permit No. TN0026450- Discharge Monitoring Report (DMR) for September 2013
ML13294A022
Person / Time
Site: Sequoyah  
Issue date: 10/11/2013
From: John Carlin
Tennessee Valley Authority
To: Morgan C
Office of Nuclear Reactor Regulation, State of TN, Dept of Environment & Conservation
References
Download: ML13294A022 (8)


Text

Tennessee Valley Authority, Post Office Box 2000, Soddy Daisy, Tennessee 37384-2000 October 11, 2013 Ms. Christina Morgan Tennessee Department of Environment and Conservation Division of Water Resources William R. Snodgrass Tennessee Tower 312 Rosa L. Parks Avenue, 11 th Floor Nashville, Tennessee 37243

Dear Ms. Morgan:

TENNESSEE VALLEY AUTHORITY (TVA) - SEQUOYAH NUCLEAR PLANT (SON) - NPDES PERMIT NO. TN0026450 - DISCHARGE MONITORING REPORT (DMR) FOR SEPTEMBER 2013 Enclosed is the September 2013 Discharge Monitoring Report for Sequoyah Nuclear Plant. The turbine building sump was discharged directly to the yard drainage pond during the month. The turbine building sump was monitored in accordance with the narrative condition found in Part I.A.2 of NPDES Permit TN0026450 and the data is provided in Attachment 1. Additionally, information pertaining to data collected and reported for Internal Monitoring Point 103 can also be found in. If you have any questions or need additional information, please contact Dawn Booker by email at sdbooker@tva.gov or by phone at (423) 843-6700.

I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.

Enclosures cc (Enclosures):

Chattanooga Environmental Field Office Division of Water Pollution Control State Office Building, Suite 550 540 McCallie Avenue Chattanooga, Tennessee 37402-2013 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555

PERMITTEE NAMEIADDRESS (Include Facility Name/Location if Different)

Name _

TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000

-(INTEROF CE OP-5N-SQN SODDY_- DAISY TN.37384 Faci.y_ TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) MAJOR DISCHARGE MONITORING REPORT (DMR)

(SUBR 01)

TN0026450 I101 G

F-FINAL PERMIT NUMBER DISCHARGE NUMBER DIFFUSER DISCHARGE MONITORING PERIOD EFFLUENT Form Approved.

OMB No. 2040-0004 IlYEARzI MO T

oDAY YEARI MO DAY From [-13-F09 01 1To 1 13 109 1301 ATTN: Dawn Booker NO DISCHARGE

[i ]

NOTE: Read instructions before completing this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE EX OF TYPE

  • AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS TEMPERATURE, WATER DEG.

SAMPLE 42.1 04 30130 RCORDR CENTIGRADE MEASUREMENT 00010 1

0 PERMIT Req. Mon.

DEG. C.

CONTI CALCTD EFFLUENT GROSS REQUIREMENT DAILY MAX NUOUS TEMPERATURE, WATER DEG.

SAMPLE

    • 29.1 04 0

30/30 MODELD CENTIGRADE MEASUREMENT 00010 Z

0 PERMIT

  • '**e**'

30.5 DEG. C.

CONTI CALCTD INSTREAM MONITORING REQUIREMENT DAILY MX NUOUS TEMP. DIFF. BETWEEN SAMP. &

SAMPLE 3

04 0

30130 CALCTD UPSTRM DEG.C MEASUREMENT 00016 1

S PERMIT 3

DEG. C.

CONTI CALCTD EFFLUENT GROSS REQUIREMENT DAILY MX NUOUS FLOW, IN CONDUIT OR THRU SAMPLE 1721 03 0

30/30 RCORDR TREATMENT PLANT MEASUREMENT 50050.

1 0

PERMIT Req. Mon.

MGD CONTI RCORDR EFFLUENT GROSS REQUIREMENT DAILY MAX NUOUS CHLORINE, TOTAL RESIDUAL SAMPLE 0.016 0.024 19 0

24/30 GRAB MEASUREMENT 50060 1

0 PERMIT 0*.*

01 0.1 MG/L.

FIVE PER CALCTD EFFLUENT GROSS REQUIREMENT MO AVG DAILY MAX WEEK TEMPERATURE - C, RATE OF SAMPLE

  • 0 62 0

30/30 CALCTD CHANGE MEASUREMENT 82234 1

0 PERMIT.

2 DEG CONTI CALCTD EFFLUENT GROSS REQUIREMENT DAILY MX C/HR NUOUS SAMPLE MEASUREMENT PERMIT REQUIREMENT NAMErTITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that thils document and all attachments were prepared under my TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified persornn John T. Carlin properly gather and evaluate the information submitted. Based on my inquiry of the person or.

persons who manage the system, or those persons directly responsible for gathering the

'nt information' the information submitted is, to the best of my knowiedge and belief, true. accu

e.

423 843-7001 13 10 11 Site Vice President and complete. I am aware that there are significant penalties for submitting false information, G

UR OF PRINCIPAL EXECUTIVE I

including the possibility of fine and imprisonment for knowing violations.

ICr OR AUTHORIZED AGENT AREAI NUMBER YEAR MO DAY TYPED OR PRINTED

__CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

No closed mode operation. The following injections occurred: 1. Floguard MS6236 (max. calc. conc. was 0.03mg/I--limit 0.2mg/L) 2. Biodetergent 73551 (max. calc. conc. was 0.036mg/L-limit 2.0mg/L) 3. Spectrus CT1 300 (max. calc. conc. was 0.0379mg/I-limit 0.050mg/L) jP-A Form 3320-1 (REV 3199)

Previous editions may be used Page 1 of I

PERMITTEE NAMEIADDRESS (Include Facility NamelLocation if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address PO. BOX 2000

.(.INTEROFIMCE QPS-N-_SQ.

SODDY - DAISY, TN 37384 Fa.c i_

TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY A-TN: Dawn Booker NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR Form Approved.

DISCHARGE MONITORING REPORT (DMR)

(SUBR 01) 0MB No. 2040-0004 TN0026450 1

101T F - FINAL PERMIT NUMBER D SCHARGENUMBER BIOMONITORING FOR OUTFALL 101 t

11liKlITl0I1iJV OVDINlfl I

EFFLUENT From 9

1 71Tog 13 I 09 I DAY-NO DISCHARGE

[ý]

NOTE: Read instructions before completing this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

EX FREQUENCY SAMPLE OF TYPE ANALYSIS r

I*

AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS IC25 STATRE 7DAY CHR CERIODAPHNIA TRP3B 1

0 EFFLUENT GROSS I~

I-I I-

-e SAMPLE MEASUREMENT Other 23 PERMIT REQUIREMENT

    • e*eeee 43.2 MINIMUM PERCENT

_t__

IC25 STATRE 7DAY CHR PIMEPHALES TRP6C 1

0 EFFLUENT GROSS SAMPLE MEASUREMENT Other 23 SEMI ANNUAL SEMI ANNUAL COMPOS 4

1

+

PERMIT REQUIREMENT 43.2 MIMINUM PERCENT COMPOS I

SAMPLE MEASUREMENT

-i

+

i.

i PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel John T. Carlin property gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted Is, to the best of my knowledge and belief, true, accurate, 423 843-7001 13 10 11 Site Vice President and complete. I am aware that there are significant penalties for submitting false information, SIGNATUR-P NCIPAL EXECUTIVE including the possibility of fine and imprisonment for knowing violations.

OFFICER ORAUTHORIZED AGENT AREAI NUMBER YEAR MO DAY TYPED OR PRINTED I CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference anl attachments here)

Toxicity sampling occurred September 15-20. The test results have not been received. The September DMR for TN toxicity will be revised and included with the October DMR.

EPA Form 3320-1 (REV 3199)

Previous editions may be used Page 1 of 1

PERMITTEE NAME/ADDRESS (Include Facilitv Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000

.(.INTEROFFICE OPS-5N-SQN)

SODDY - DAISY TN.37384.

Fac2ii_

TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR Form DISCHARGE MONITORING REPORT (DMR)

(SUBR 01)

OMBr TN0026450 i

103 F - FINAL PERMIT NUMBER DISCHARGE NUMBEI LOW VOL. WASTE TREATMENT POND MONITORING PERIOD EFFLUENT Approved.

No. 2040-0004 ATTN: Dawn Booker I YEAR I MO

!DAY I

IY-EAR I -MO I DAY I O

SC A G From[ 13 09 01 To 3

9I0 NO DISCHARGE3[

NOTE: Read instructions before completing this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS PH SAMPLE 6

8 12 0

16/30 GRAB MEASUREMENT 00400 1

0 PERMIT

      • 55**

6 9

SU THREE/

GRAB EFFLUENT GROSS REQUIREMENT MINIMUM MAXIMUM WEEK SOLIDS, TOTAL SUSPENDED SAMPLE 15 15 19 0

2/30 GRAB MEASUREMENT 00530 1

0 PERMIT 30 100 MGIL TWICE/

GRAB EFFLUENT GROSS REQUIREMENT MO AVG DAILY MX MONTH OIL AND GREASE SAMPLE

<5

<5 19 0

2/30 GRAB MEASUREMENT 00556 1

0 PERMIT 15 20 MGIL TWICE/

GRAB REQUIREMENTMOT EFFLUENT GROSS MO AVG DAILY MX MONTH FLOW, IN CONDUIT OR THRU SAMPLE 1.095 1.327 03

  • 30/30 RCORDR TREATMENT PLANT MEASUREMENT 50050.

1 0

PERMIT Req. Mon.

Req. Mon MGD

          • e**

SEE RCORDR EFFLUENT GROSS REQUIREMENT MO AVG DAILY MX PERMIT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel John T. Carlin properly gather and evaluate the Information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, 423 843-7001 13 10 11 Site Vice President and complete. I am aware that there are significant penalties for submitting false information.

SIGNIDPZE PRINCIPAL EXECUTIVE including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY TYPED OR PRINTED coDEE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

The Turbine Building Sump (TBS) was discharged directly to the Yard Pond (YP) on 0911812013-0911912013. Monitoring data is included in attachment 1.

EPA Form 3320-1 (REV 3199)

Previous editions may be used Page 1 of 1

PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000

- (-NTEROFFICE OPS-5N-SQ..N).

SODDY - DAISY, TN 37384 FaciL___ TVA -SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY ATTN: Dawn Booker NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

DISCHARGE MONITORING REPORT (DMR)

TN0026450 LDIS 110 G ERMNUMBER DRGE NUMBER MONITORING PERIOD EA ToYEAR mg DA From l13 109 01 To l 13 109 1301 MAJOR Form Approved.

(SUBR 01)

OMB No. 2040-00 F - FINAL RECYCLED COOLING WATER EFFLUENT

  • NO DISCHARGE Ik x-NOTE: Read instructions before completinr this form.

004 PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS TEMPERATURE, WATER DEG.

SAMPLE 04 CENTIGRADE MEASUREMENT 04 00010 1

0 PERMIT REPORT DEG C CONTIN CALCTD EFFLUENT GROSS VALUE REQUIREMENT DAILY MX UOUS TEMPERATURE, WATER DEG.

SAMPLE 04 CENTIGRADE MEASUREMENT 04 00010 Z

0 PERMIT 30.5 DEG C CONTIN CALCTD INSTREAM MONITORING REQUIREMENT DAILY MX UOUS TEMP. DIFF. BETWEEN SAMP. &

SAMPLE 04 UPSTRM DEG.C MEASUREMENT 00016 1

0 PERMIT 5

DEG C COINTIN CALCTD EFFLUENT GROSS VALUE REQUIREMENT DAILY MX UOUS FLOW, IN CONDUIT OR THRU SAMPLE 03 TREATMENT PLANT MEASUREMENT 03 50050 1

0 PERMIT Req. Mon.

MGD CONITIN RCORDR EFFLUENT GROSS VALUE REQUIREMENT DAILY MX UOUS CHLORINE, TOTAL RESIDUAL SAMPLE 19 MEASUREMENT 50060 1

0 PERMIT 0.1 0.1 MGIL Five per CALCTD EFFLUENT GROSS VALUE REQUIREMENT MO AVG DAILY MX Week TEMPERATURE - C, RATE OF SAMPLE CHANGE MEASUREMENT 04 82234 1

0 PERMIT 2

DEG C CONTIN CALCTD EFFLUENT GROSS VALUE REQUIREMENT DALY MXous SAMPLE MEASUREMENT PERMIT REQUIREMENT I NAME/TITLE PRINCIPAL EXECUTIVE OFFICER John T. Carlin Site Vice President I Certify under penalty ao law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted Is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, i

TYPED OR PRINTED COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all aftachments here)

No Discharge this Period EPA Form 3320-1 (REV 3199)

Previous editions may be used Page 1 of 1

PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000

_INTEROFFICE OPS-5N-SQN.)

SODDY - DAISY, TN._337384_.

Facj&

TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR DISCHARGE MONITORING REPORT (DMR)

(SUBR 01)

L TN0026450 ý 1

110 T F - FINAL PERMIT NUMBER II DISCHARGE NUMBER RECYCLED COOLING WATER

. MONITORING PERIO EFFLUENT Form Approved.

OMB No. 2040-0004 I YEAro-MO I DAY I T YEAR IoMO I DAY I From 1 13 1 09 1 01 1 To [ _13 Ij I 9 01 ATTN: Dawn Booker NO DISCHARGE. []

NOTE: Read instructions before comoleting this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS IC25 STATRE 7DAY CHR SAMPLE 23 CERIODAPHNIA MEASUREMENT TRP3B 1

0 0

PERMIT 43.2

  • s*****'

PERCENT SEMI COMPOS EFFLUENT GROSS VALUE REQUIREMENT MINIMUM ANNUAL IC25 STATRE 7DAY CHR SAMPLE 23 PIMEPHALES MEASUREMENT 23 TRP6C 1

0 0

PERMIT

    • 5***

43.2 PERCENT SEMI COMPOS EFFLUENT GROSS VALUE REQUIREMENT MINIMUM ANNUAL SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE

-direction or supervision in accordance with a system designed to assure that qualified personnel John T. Carlin property gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the nt information, the information submitted Is, to the best of my knowledge and belief, true, accurate.

423 843-7001 13 10 11 Site Vice President and complete. I am aware that there are significant penalties for submitting false information, SIG N-,Tblf. OF PRINCIPAL EXECUTIVE including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY TYPED OR PRINTED CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

No Discharge this Period EPA Form 3320-1 (REV 3199)

Previous editions may be used Page 1 of 1

PERMITTEE NAME/ADDRESS (Include Facility NamelLocation if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address __P.O. BOX 2000

-[NTEROFMCE OPS-5N-SQN)

SODDY.-

DAISY. TN 37384 Facf.

TVA - SEQUOYAH NUCLEAR PLANT Location_

HAMILTON COUNTY ATTN: Dawn Booker NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

DISCHARGE MONITORING REPORT (DMR)

)2~6450

ý 1

PERMIT NUMBER DISC-RGE NUMBER MONITORING PERIOD YEAro MOL DAY I IOL EAR M0 Froml 13109I 01 1 To°1 13109 130J MAJOR Form Approved.

(SUBR 01)

OMB No. 2040-01 F -FINAL WASTEWATER & STORM WATER EFFLUENT NO DISCHARGE [6..

NOTE: Read instructions before completing this form.

004 PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS OXYGEN, DISSOLVED (DO)

SAMPLE 19 MEASUREMENT 1

00300 1

0 PERMIT w*wee*e*

2 MGIL TWICE/

GRAB EFFLUENT GROSS REQUIREMENTMINIMUM WEEK SOLIDS, TOTAL SUSPENDED SAMPLE 1***9***

MEASUREMENT 00530 1

0 PERMIT 100 MGIL TWICE/

GRAB EFFLUENT GROSS REQUIREMENT DAILY MX WEEK SOLIDS, SETTLEABLE SAMPLE 25 MEASUREMENT 00545 1

0 PERMIT 1

MUL ONCE/

GRAB EFFLUENT GROSS REQUIREMENT DAILY MX MONTH FLOW, IN CONDUIT OR THRU SAMPLE 03 TREATMENT PLANT MEASUREMENT 03 50050 1

0 PERMIT Req. Mon.

Req. Mon.

MGD ONCE/

ESTIMA EFFLUENT GROSS REQUIREMENT MO AVG DAILY MX BATCH SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE

direction or supervision in accordance with a system designed to assure that qualified personnel John T. Carlin properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information. the information submitted is, to the best of my knowledge and belief, true, accurate, r

423 843-7001 13 10 11 Site Vice President and complete. I am aware that there are significant penalties for submitting false information, SN N OF PRINCIPAL EXECUTIVE T Pincluding the possibility of fine and imprisonment for knowing violations.

OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY TYPED OR PRINTED____________________________________________CE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

During this reporting period, there has been no flow from the Dredge Pond other than that resulting from rainfall.

EPA Form 3320-1 (REV 3199)

Previous editions may be used Page I of I

TVA Sequoyah Nuclear Plant NPDES Permit No. TN0026450 Turbine Building Sump Monitoring Data The turbine building sump was discharged directly to the yard drainage pond from 09/18/2013 to 09/19/2013. During this period, the turbine building sump was monitored in accordance with the narrative condition found in Part 1.A.2 of NPDES Permit TN0026450.

Parameter Daily Minimum Monthly Average Daily Maximum No. of Samples Flow 1.045 MGD 1.045 MGD 2

pH 8 s.u.

8 s.u.

2 O&G

< 5 mg/L

<5 mg/L 2

TSS 4 mg/L 4 mg/L 2

Internal Monitoring Point 103 Additional Information On 9/16/2013 at 0925 EDT the pH at Internal Monitoring Point (IMP) 103 was 5.9 s.u. Follow up samples were collected at 0945 EDT and 1003 EDT with a result of 5.7 s.u. each time. SQN responded by isolating IMP 103 to stop the discharge. Additionally, a sample was collected at SQN Outfall 101 (Diffuser Discharge to Tennessee River) and the pH was 7.1 s.u. This demonstrates that discharge to the Tennessee River did not contribute to a violation of instream water quality criteria per Rule 1200-04-03.03.

SQN attributed the lower pH levels to the low volume waste treatment pond being at an abnormally low elevation. After the pond elevation was raised, SQN reinitiated discharge from Internal Monitoring Point 103 on 9/17/2013. A sample was collected at 1400 EDT and the pH was 6.8 s.u. Monitoring results were reported on the DMR in accordance with the permit limitations and DMR set example provided by TDEC. No permit violation had occurred, although this information was provided in abundance of caution and to remain transparent.