ML13281A802

From kanterella
Jump to navigation Jump to search
Notification of Deviation from BWRVIP-183
ML13281A802
Person / Time
Site: River Bend 
(NPF-047)
Issue date: 10/02/2013
From: Clark J
Entergy Operations
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RBG- 47395
Download: ML13281A802 (5)


Text

Entergy Operations, Inc.

River Bend Station 5485 U.S. Highway 61N St. Francisville, LA 70775 En ter 7 Tel 225-381-4177 Joseph A. Clark Manager-Licensing RBG-47395 October 2, 2013 U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555

Subject:

Notification of Deviation from BWRVIP-183 River Bend Station - Unit 1 Docket No. 50-458 License No. NPF-47 This letter provides notification of a deviation from the Boiling Water Reactor Vessel and Internals Project (BWRVIP) guidelines for River Bend Station. This is a deviation from the performance of inspection in accordance with the examination schedules of BWRVIP-183, "BWR Vessel and Internals Project, Top Guide Grid Beam Inspection and Flaw Evaluation Guidelines," (EPRI Report 1013401, December 2007).

This is a deviation from a "needed" element of the BWRVIP program to perform inspections in accordance with the guidance of BWRVIP-183. BWRVIP-183 requires an inspection of the top guide rim area and two cells every six years and implementation of this inspection should have been completed by Refuel Outage16 (2011). It was discovered that this top guide inspection has not been completed to date at River Bend. The inspection has been scheduled for the next refuel outage which is Refuel Outage 18 (2015).

This deviation from the BWRVIP guidelines has been reviewed and approved in accordance with Entergy procedures and NEI 03-08 guidance. This is a notification of deviation only, and no action is being requested from the NRC.

The attachment to this letter provides a summary of the regulatory commitment made in this submittal.

AJ??oC

RBG-47395 Page 2 of 2 Should you have any questions regarding this deviation, please contact me at (225) 381-4177.

Sin I

Joseph A. Clark Manager - Licensing RBF1-13-0121 Attachment List of Regulatory Commitments cc: Regional Administrator U. S. Nuclear Regulatory Commission Region IV 1600 E. Lamar Blvd.

Arlington, TX 76011-4511 NRC Senior Resident Inspector P. 0. Box 1050 St. Francisville, LA 70775 U. S. Nuclear Regulatory Commission Attn: Mr. Alan Wang MS 0-8B1 One White Flint North 11555 Rockville Pike Rockville, MD 20852 Louisiana Department of Environmental Quality Office of Environmental Compliance Radiological Emergency Planning and Response Section JiYoung Wiley P. O. Box 4312 Baton Rouge, LA 70821-4312 Public Utility Commission of Texas Attn: PUC Filing Clerk 1701 N. Congress Avenue P. O. Box 13326 Austin, TX 78711-3326

Attachment RBG-47395 List of Regulatory Commitments

RBG-47395 Attachment to Page 1 of 1 List of Regulatory Commitments The following table identifies those actions committed to by Entergy in this document. Any other statements in this submittal are provided for information purposes and are not considered to be regulatory commitments.

TYPE (Check one)

SCHEDULED ONE-CONTINUING COMPLETION COMMITMENT TIME COMPLIANCE DATE ACTION The inspection has been scheduled for the next X

RF-18 refuel outage which is Refuel Outage 18 (Spring 2015)

OUTGOING CORRESPONDENCE CHECKLIST

1.

Verify transmittal and document is in accordance with Preparation/Acceptance Stds

2.

Retrieve yellow folder & Outgoing Checklist

3.

Numbers RBFI -

RBG -

Verify that the corlog & correspondence issue log have the correct information

4.

Make Label {RBF #, RBG, subject}

5.

Make Copies Copies will be mailed to the individuals listed in the cc: section of letter.

Addressee of the letter gets the original. {W/O on the cc: list means without attachments}

6.
1. Scan 2. Rename to RBG# 3. MOVE to my F: drive 4. Paper capture 5. COPY to the ( N or L drive)
6. Rename to the RBFI # (example: 1120120)

N:llrs docsllicrbgslpdfsll12xxr.--doc OR Security Related Letter L:I12rbfll2Ol2 Security Confidential OR Operator Confidential Letter L:l12rbfl12012 Operator Confidential

7.

Elog Make entry into the electronic log of the Licensing Research System (LRS)

8.

Email Engineer Notify Licensing Lead that the Letter is in the Elog for review

9.

Email Send electronic copy to the following distribution & attach letter from the N: or L: drive (as appropriate): {this list will change as position are vacated & refilled}

EXCEPTION: Ops Confidential & Security Confidential (see outgoing distribution list for these}

Eric Olson Donna Fancher Richard Gadbois Jerry Roberts Bryan Ford Roger Persons Joey Clark John McCann Mike Boyle Charlene Faison

10.

Retrieve indexing guides and enter the letter into eB following the guide /Import Image

11.

Get document independent verified.

12.

File original letter in the cabinet. {ensure is filed in the PPI cabinet}

J:1LicAIdmn1nOutgoing Correspondence Checklistdoc 10/23/2012