Other: ML13338A510, ML14006A187, ML15117A666, ML15133A501, ML15208A027, NRC 2013-0077, NextEra Energy Point Beach, LLCs First Six Month Status Report in Response to March 12, 2012 Commission Order to Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051), NRC 2013-0078, NextEra Energy Point Beach, LLCs First Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Numbe, NRC 2014-0051, Final Six Month Status Report in Response to March 12, 2012 Commission Order to Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order No. EA-12-051), NRC 2014-0077, NextEra Energy Point Beach, LLCs Full Compliance Report for the March 12, 2012 Commission Order to Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051), NRC 2015-0056, Fifth Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Number EA-12-049), NRC 2015-0072, Notification of Full Compliance with Order EA-12-049, Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design Basis External Events and Submittal of Final Integrated Plan, NRC 2016-0028, Response to Interim Staff Evaluation Open and Confirmatory Items for Order EA-12-049 Modifying License with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events
|
MONTHYEARML13039A4352013-02-22022 February 2013 Letter Acknowledgement Letter for 60-day Response to Issuance of Flooding Integrated Assessment Guidance Related to the NTTF Recommendation 2.1, Flooding Reevaluations Project stage: Request NRC 2013-0053, Response to Request for Additional Information Regarding Overall Integrated Plan in Response to Order EA-12-051, Reliable Spent Fuel Pool Instrumentation2013-07-0303 July 2013 Response to Request for Additional Information Regarding Overall Integrated Plan in Response to Order EA-12-051, Reliable Spent Fuel Pool Instrumentation Project stage: Response to RAI NRC 2013-0078, NextEra Energy Point Beach, LLCs First Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Numbe2013-08-28028 August 2013 NextEra Energy Point Beach, LLCs First Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Number EA- Project stage: Other NRC 2013-0077, NextEra Energy Point Beach, LLCs First Six Month Status Report in Response to March 12, 2012 Commission Order to Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051)2013-08-28028 August 2013 NextEra Energy Point Beach, LLCs First Six Month Status Report in Response to March 12, 2012 Commission Order to Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051) Project stage: Other NRC 2013-0088, NextEra Energy Point Beach, LLC Preliminary Schedule for GSI-191 Resolution2013-09-30030 September 2013 NextEra Energy Point Beach, LLC Preliminary Schedule for GSI-191 Resolution Project stage: Request ML13309A0112013-11-18018 November 2013 Interim Staff Evaluation and Request for Additional Information Regarding Order EA-12-051 Project stage: RAI ML14006A1872014-01-10010 January 2014 Mega-Tech Services, LLC Technical Evaluation Report Regarding the Overall Integrated Plan for Point Beach Station, Units 1 and 2, TAC Nos.: MF0725 and MF0726 Project stage: Other ML13338A5102014-01-27027 January 2014 Interim Staff Evaluation and Audit Report Relating to Overall Integrated Plan in Response to Order EA-12-049 - Mitigation Strategies Project stage: Other NRC 2014-0051, Final Six Month Status Report in Response to March 12, 2012 Commission Order to Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order No. EA-12-051)2014-08-28028 August 2014 Final Six Month Status Report in Response to March 12, 2012 Commission Order to Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order No. EA-12-051) Project stage: Other NRC 2014-0077, NextEra Energy Point Beach, LLCs Full Compliance Report for the March 12, 2012 Commission Order to Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051)2014-12-19019 December 2014 NextEra Energy Point Beach, LLCs Full Compliance Report for the March 12, 2012 Commission Order to Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051) Project stage: Other ML15117A6662015-05-0404 May 2015 Plan for the Onsite Audit Regarding Implementation of Mitigating Strategies and Reliable Spent Fuel Instrumentation Related to Orders EA-12-049 and EA-12-051 Project stage: Other ML15133A5012015-05-14014 May 2015 Correction Letter Regarding Plan for the Onsite Audit Regarding Implementation of Mitigating Strategies and Reliable Spent Fuel Pool Instrumentation Related to Orders EA-12-051 Project stage: Other ML15208A0272015-08-27027 August 2015 Report for the Onsite Audit Regarding Implementation of Mitigating Strategies Related to Order EA-12-049 Project stage: Other NRC 2015-0056, Fifth Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Number EA-12-049)2015-08-28028 August 2015 Fifth Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Number EA-12-049) Project stage: Other NRC 2015-0072, Notification of Full Compliance with Order EA-12-049, Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design Basis External Events and Submittal of Final Integrated Plan2015-12-16016 December 2015 Notification of Full Compliance with Order EA-12-049, Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design Basis External Events and Submittal of Final Integrated Plan Project stage: Other NRC 2016-0028, Response to Interim Staff Evaluation Open and Confirmatory Items for Order EA-12-049 Modifying License with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events2016-06-22022 June 2016 Response to Interim Staff Evaluation Open and Confirmatory Items for Order EA-12-049 Modifying License with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events Project stage: Other 2014-12-19
[Table View] |
Text
NEXTera ENERGY\\/-"
POINT BEACH September 30, 2013 NRC 2013-0088 GL 2004-02 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Point Beach Nuclear Plant, Units 1 and 2 Docket 50-266 and 50-301 Renewed License Nos. DPR-24 and DPR-27 NextEra Energy Point Beach, LLC Preliminary Schedule for GSI-1 91 Resolution
References:
- 1. NextEra Energy Point Beach, LLC letter to U.S. Nuclear Regulatory Commission, Resolution Option and Implementation Schedule for GSI-191 Closure, dated May 16, 2013 [ML13140A013]
- 2. U.S. Nuclear Regulatory Commission Generic Letter 2004-02: Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accident at Pressurized-Water Reactors, dated September 13, 2004 [ML042360586]
- 3. U.S. Nuclear Regulatory Commission, Closure Options for Generic Safety Issue - 191, Assessment of Debris Accumulation on Pressurized-Water Reactor Sump Performance, Commission Paper SECY-12-0093, dated July 9, 2012 [ML121310648]
By letter dated May 16, 2013 (Reference 1), NextEra Energy Point Beach, LLC (Point Beach) notified the U.S. Nuclear Regulatory Commission that Point Beach had selected Option 3 for resolution of Generic Safety Issue (GSI) 191 (Reference 2), in accordance with the Closure Options specified in Commission Paper SECY-12-0093 (Reference 3).
Option 3 is different regulatory treatment for suction strainer and in-vessel effects resolution.
In Reference 1, Point Beach committed to submit preliminary schedules for resolution of containment sump recirculation suction strainer performance and resolution of in-vessel effects. The preliminary schedules contain key milestone dates for resolution of the issues, and are provided in the enclosure to this letter.
NextEra Energy Point Beach, LLC, 6610 Nuclear Road, Two Rivers, Wl 54241
Document Control Desk Page 2 This letter contains no new regulatory commitments.
If you have any questions, please contact Mr. Michael Millen, Licensing Manager, at 920/755-7845.
I declare under penalty of perjury that the foregoing is true and correct.
Executed on September 30, 2013.
Very truly yours, NextEra Energy Point Beach, LLC Vice President Enclosure cc:
Administrator, Region Ill, USNRC Resident Inspector, Point Beach Nuclear Plant, USNRC Project Manager, Point Beach Nuclear Plant, USNRC
ENCLOSURE NEXTERA ENERGY POINT BEACH, LLC POINT BEACH NUCLEAR PLANT, UNITS 1 AND 2 NEXTERA ENERGY POINT BEACH, LLC PRELIMINARY GSI-191 RESOLUTION SCHEDULE 1
Introduction By letter dated May 16, 2013 (Reference 1), NextEra Energy Point Beach, LLC (Point Beach) notified the U.S. Nuclear Regulatory Commission that Point Beach had selected Option 3 for resolution of GSI-191, in accordance with the Closure Options specified in Commission Paper SECY-12-0093 (Reference 2). Option 3 is deterministic resolution for suction strainer blockage and risk-based resolution for in-vessel effects. In Reference 1, Point Beach committed to submit preliminary schedules for GSI-191 resolution that address both suction strainer and in-vessel effects resolution. The preliminary schedules are provided in this enclosure.
2 Milestone Schedules The preliminary schedules provided in this enclosure contain the major milestones for resolving the suction strainer performance using a deterministic resolution strategy and the major milestones for resolving the issue of in-vessel effects using a risk-based approach.
Table 1 presents the major milestones for deterministic resolution of suction strainer performance. Table 2 presents major milestones for resolution of in-vessel effects using a risk-based approach.
Table I Suction Strainer Deterministic Resolution MILESTONE MILESTONE DATE1 Develop Containment CAD Model JAN 2014 Refine Debris Generation Analysis JUN 2014 Conduct strainer head loss testing SEP 2014 Analyze head loss test results DEC 2014 Perform additional head loss testing, if MAR 2015 necessary Submit NEI 04-07 Exemption Request, if SEP 2015 necessary 2
Approve Unit 1 modification package DEC 2016 Approve Unit 2 modification package MAR 2017 Install Unit 1 modifications DEC 2017 Install Unit 2 modifications NOV 2018 Milestone Dates are subject to change as implementation details are developed.
2 NEI 04-07 Exemption Request for use of Alternate Analysis Approach Page 1 of 2
Table 2 In-Vessel Effects Risk-Based Resolution MILESTONE MILESTONE DATE1 Develop Containment CAD Model JAN 2014 Refine Debris Generation Analysis JUN 2014 Modify Plant PRA Model JUN 2014 Thermal Hydraulics modeling JUN 2015 Evaluate Boric Acid precipitation impact SEP 2015 Chemical Effects testing JAN 2016 Determine ACDF and ALERF MAR 2016 Submit License Amendment Request SEP 2016 Approve Unit 1 modification package DEC 2016 Approve Unit 2 modification package JUN 2017 Receive NRC Safety Evaluation SEP 2017 Install Unit 1 modifications 2 DEC 2017 Install Unit 2 modifications 2 NOV 2018 Install Unit 1 supplemental modifications3 JUN 2019 Install Unit 2 supplemental modifications3 JUN 2020 1 Milestone Dates are subject to change as implementation details are developed.
2 Modifications identified in the License Amendment Request 3 Potential modifications identified during the License Amendment approval process 3
References
- 1. NextEra Energy Point Beach, LLC letter to U.S. Nuclear Regulatory Commission, Resolution Option and Implementation Schedule for GSI-191 Closure, dated May 16, 2013 [ML13140A013]
- 2. U.S. Nuclear Regulatory Commission, Closure Options for Generic Safety Issue - 191, Assessment of Debris Accumulation on Pressurized-Water Reactor Sump Performance, Commission Paper SECY-12-0093, dated July 9, 2012 [ML121310648]