ML13254A115

From kanterella
Jump to navigation Jump to search
Attachment 2 - Updated Evacuation Time Estimates for Byron Station Plume Exposure Pathway and ETE Review Criteria Checklist
ML13254A115
Person / Time
Site: Byron  Constellation icon.png
Issue date: 09/05/2013
From:
Exelon Generation Co
To:
NRC/FSME, Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation
References
RA-13-085, RS-13-221, TMI-13-137
Download: ML13254A115 (154)


Text

ATTACHMENT 2 Updated Evacuation Time Estimates for Byron Station Plume Exposure Pathway and ETE Review Criteria Checklist

Byron Station ETE Review Criteria Checklist

Table B-I ETE Review Criteria Checklist Byron Criterion Addressed in Comments ETE Analysis (Yes/No) 1.0 Introduction

a. The emergency planning zone (EPZ) and surrounding area should be described, yes Sect 1.2
b. A map should be included that identifies primary features of the site, including major roadways, significant topographical yes Figure 1-1, Figure 1-2 and Figure 4-1 features, boundaries of counties, and population centers within the EPZ.
c. A comparison of the current and previous ETE should be provided and includes similar information as identified in yes Table 1-3 Table 1-1, "ETE Comparison," of NUREG/CR-7002.

1.1 Approach

a. A discussion of the approach and level of detail obtained during the field survey of the roadway network should be yes Section 4.3 and Appendix C provided.
b. Sources of dem ographic data for schools, special facilities, yeS ct2 1, e t2., e t3 3,a d e t3 4 large employers, and special events should be identified.

yes Sect 2.1, Sect 2.2, Sect 3.3, and Sect 3.4

c.

Discussion should be presented on use of traffic controlyeS ct21ad et4.

plans in the analysis.

yes Sect 2.1 and Sect 4.3

d.

Traffic simulation models used for the analyses should be identified by name and version.

yes Sect 5.5.2 and Table 1-3

e. Methods used to address data uncertainties should be described, yes Sect 3 (avoid double counts), App B (confidence level) 1.2 Assumptions
a. The planning basis for the ETE includes the assumption that the evacuation is ordered promptly and no early protective yes Sect 1.4, Sect 2.1, Sect 3, and Sect 5.4 actions have been implemented.
b. Assumptions consistent with Table 1-2, "General Assumptions," of NUREG/CR-7002 should be provided and yes Sect 2.1 include the basis to support their use.

1.3 Scenario Development

a. The ten scenarios in Table 1-3, Evacuation Scenarios, should be developed for the ETE analysis, or a reason yes Sect 2.4, Table 6-1, Table 6-2 (no "Special Event")

should be provided for use of other scenarios.

,P

Criterion Addressed in ETE Analysis (Yes/No) 1.3.1 Staged Evacuation

a. A discussion should be provided on the approach used in development of a staged evacuation.

yes 1.4 Evacuation Planning Areas

a. A map of the EPZ with emergency response planning areas yes Figure 1.1 and Figure 4-1 (ERPAs) should be included.
b. A table should be provided identifying the ERPAs considered for each ETE calculation by downwind direction yes Table 5-1 and Table 6-2 in each sector.
c. A table similar to Table 1-4, "Evacuation Areas for a Staged Evacuation Keyhole," of NUREG/CR-7002 should be yes Table 6-3 provided and includes the complete evacuation of the 2, 5, and 10 mile areas and for the 2 mile area/5 mile keyhole evacuations.

2.0 Demand Estimation

a. Demand estimation should be developed for the four population groups, including permanent residents of the yes Table 3-1 thru 3-4 EPZ, transients, special facilities, and schools.

2.1 Permanent Residents and Transient Population

a. The US Census should be the source of the population values, or another credible source should be provided, yes Sect 2.1 and Sect 3
b. Population values should be adjusted as necessary for growth to reflect population estimates to the year of the ETE. yes 2010 Census released in Oct 2011 and is most recent
c. A sector diagram should be included, similar to Figure 2-1, "Population by Sector," of NUREG/CR-7002, showing the yes Figure 1-2 population distribution for permanent residents.

2.1.1 Permanent Residents with Vehicles

a. The persons per vehicle value should be between I and 2 or justification should be provided for other values, yes Sect 3.1.1
b.

Major employers should be listed.

yes Table A-1 2.1.2 Transient Population

a. A list of facilities which attract transient populations should be included, and peak and average attendance for these yes Table A-2 and A-3 facilities should be listed. The source of information used to develop attendance values should be provided.
b. The average population during the season should be used, yes Sect 3.3 N)

Criterion Addressed in ETE Analysis (Yes/No) itemized and totaled for each scenario.

c. The percent of permanent residents assumed to be atyeS ct3,Tal A-an A2 facilities should be estimatedTable A-and A-2
d. The number of people per vehicle should be provided.

Numbers may vary by scenario, and if so, discussion on why yes Sect 2.1, 3.3, Tables A-i, A-2, A-3 values vary should be provided.

e. A sector diagram should be included, similar to Figure 2-1 of NUREG/CR-7002, showing the population distribution for yes Distribution by ERPA by scenario in Table 3-2 the transient population.

2.2 Transit Dependent Permanent Residents

a. The methodology used to determine the number of transit dependent residents should be discussed.

yes Sect 3.1.2

b. Transportation resources needed to evacuate this group yes Sect 3.1.2, Sect 3.6, Table 3-5 should be quantified.

yesSect_3.1.2,_Sect_3.6,_Table_3-5

c. The county/local evacuation plans for transit dependent yes Sect 3.1.2 residents should be used in the analysis.
d. The methodology used to determine the number of people with disabilities and those with access and functional needs yes Sect 3.1.2 who may need assistance and do not reside in special facilities should be provided. Data from local/county registration programs should be used in the estimate, but should not be the only set of data.
e. Capacities should be provided for all types of transportation resources. Bus seating capacity of 50% should be used or yes Sect 2.1, Sect 3.1.2 justification should be provided for higher values.
f.

An estimate of this population should be provided and information should be provided that the existing registration yes Sect 3.1.2 programs were used in developing the estimate.

g. A summary table of the total number of buses, ambulances, or other transport needed to support evacuation should be yes Sect 3.6 and Table 3-5 provided and the quantification of resources should be detailed enough to assure double counting has not occurred.

2.3 Special Facility Residents

a. A list of special facilities, including the type of facility, location, and average population should be provided.

yes Table A-6 Special facility staff should be included in the total special w

Criterion Addressed in Comments ETE Analysis (Yes/No) facility population.

b. A discussion should be provided on how special facility data yes Sect 3.4 was obtained.
c. The number of wheelchair and bed-bound individuals should be provided.

yes Table A-6

d. An estimate of the number and capacity of vehicles needed to support the evacuation of the facility should be provided, yes Table A-6
e. The logistics for mobilizing specially trained staff (e.g.,

medical support or security support for prisons, jails, and yes Sect 3.4.1, Sect 5.4.3 other correctional facilities) should be discussed when appropriate.

2.4 Schools

a. A list of schools including name, location, student population, and transportation resources required to support yes Sect 3.4.2, Table 3-3 & Table A-4 the evacuation, should be provided. The source of this information should be provided.
b. Transportation resources for elementary and middle schools are based on 100% of the school capacity.

yes Sect 3.4.2, Table A-4

c. The estimate of high school students who will use their personal vehicle to evacuate should be provided and a basis yes Sect 3.4 Plans assume all students by bus for the values used should be provided.
d. The need for return trips should be identified if necessary.

yes Sect 3.6 and Sect 6.7 (no return trips) 2.5.1 Special Events

a. A complete list of special events should be provided and includes information on the population, estimated duration, yes Sect 2.4.4 (no events identified) and season of the event.
b. The special event that encompasses the peak transient N/A Sect 2.4.4 population should be analyzed in the ETE.
c. The percent of permanent residents attending the event N/A Sect 2.4.4 should be estimated.

2.5.2 Shadow Evacuation

a. A shadow evacuation of 20 percent should be included for areas outside the evacuation area extending to 15 miles yes Figure 1-2 and Sect 3.1.1 from the NPP.
b. Population estimates for the shadow evacuation in the 10 to 15 mile area beyond the EPZ are provided by sector.

yes Figure 1-2 CD

Criterion Addressed in Comments ETE Analysis (YesINo)

c. The loading of the shadow evacuation onto the roadway network should be consistent with the trip generation time yes Sect 5 generated for the permanent resident population.

2.5.3 Background and Pass Through Traffic

a. The volume of background traffic and pass-through traffic should be based on the average daytime traffic. Values may yes Sect 2.1, 4.3 be reduced for nighttime scenarios.
b. Pass-through traffic should be assumed to have stopped entering the EPZ about two hours after the initial notification.

yes Sect 2.1, 4.3 2.6 Summary of Demand Estimation

a. A summary table should be provided that identifies the total populations and total vehicles used in the analysis for yes Table 3-1 thru 3-4; vehicle demand for shadow permanent residents, transients, transit dependent population is discussed in Section 3.1.1 residents, special facilities, schools, shadow population, and pass-through demand used in each scenario.

3.0 Roadway Capacity

a. The method(s) used to assess roadway capacity should be yes Sect 4 discussed.jysSc4 3.1 Roadway Characteristics
a. A field survey of key routes within the EPZ has been conducted.

yes Sect 4.1

b.

Information should be provided describing the extent of the survey, and types of information gathered and used in the yes Sect 4.3 analysis.

c. A table similar to that in Appendix A, "Roadway ysA p ni Characteristics," of NUREG/CR-7002 should be provided, yes Appendix C
d. Calculations for a representative roadway segment should ye pni C

beyes Appendix C

e. A legible map of the roadway system that identifies nodeyeMa inA p dxC numbers and segments used to develop the ETE should be yes Map in Appendix C provided and should be similar to Figure 3-1, "Roadway Network Identifying Nodes and Segments," of NUREG/CR-7002.

3.2 Capacity Analysis

a. The approach used to calculate the roadway capacity for the yes transportation network should be described in detail and Sect 4.3 and Appendix C 91 oln

Criterion Addressed in Comments ETE Analysis (YeslNo) identifies factors that are expressly used in the modeling.

b. The capacity analysis identifies where field information should be used in the ETE calculation.

Sect 4.3 3.3 Intersection Control

a. A list of intersections should be provided that includes the total numbers of intersections modeled that are yes Appendix C (Node Data Table) unsignalized, signalized, or manned by response personnel.
b. Characteristics for the 10 highest volume intersections within the EPZ are provided including the location, signal cycle yes Table 7-1 length, and turn lane queue capacity.
c. Discussion should be provided on how time signal cycle is used in the calculations.

yes Sect 4.3 3.4 Adverse Weather

a. The adverse weather condition should be identified and the effect of adverse weather on mobilization should be yes Sect 2.4 considered,
b. The speed and capacity reduction factors identified in Table 3-1, "Weather Capacity Factors," of NUREG/CR-7002 yes Sect 2.4 should be used or a basis should be provided for other values.
c. The study identifies assumptions for snow removal on N/A Part of Protective Action Decision process streets and driveways, when applicable.

4.0 Development of Evacuation Times 4.1 Trip Generation Time

a. The process used to develop trip generation times should be yes Sect 5 identified.
b. When telephone surveys are used, the scope of the survey, area of the survey, number of participants, and statistical yes Appendix B relevance should be provided.
c. Data obtained from telephone surveys should be summarized.

yes Appendix B

d. The trip generation time for each population group should be yes Sect 5 developed from site specific information.

4.1.1 Permanent Residents and Transient Population

a. Permanent residents are assumed to evacuate from their homes but are not assumed to be at home at all times. Trip yes Sect 5.4.1 0)

Criterion Addressed in Comments ETE Analysis (Yes/No) generation time includes the assumption that a percentage of residents will need to return home prior to evacuating.

b. Discussion should be provided on the time and method used to notify transients. The trip generation time discusses any yes Sect 5 difficulties notifying persons in hard to reach areas such as on lakes or in campgrounds.
c. The trip generation time accounts for transients potentially returning to hotels prior to evacuating, yes Sect
d.

Effect of public transportation resources used during special events where a large number of transients are expected N/A should be considered.

e. The trip generation time for the transient population should be integrated and loaded onto the transportation network yes Sect 5 with the general public.

4.1.2 Transit Dependent Residents

a. If available, existing plans and bus routes are used in the ETE analysis. If new plans are developed with the ETE, they yes Sect 5.3 and Sect 6.7 should have been agreed upon by the responsible authorities.
b. Discussion should be included on the means of evacuating ambulatory and non-ambulatory residents.

yes Sect 5.3 and Sect 6.7

c. The number, location and availability of buses, and other resources needed to support the demand estimation are N/A Transportation resources are part of offsite agency
provided, planning process
d.

Logistical details, such as the time to obtain buses, brief drivers and initiate the bus route are provided, yes Sect 5.4.3 and Sect 6.7

e. Discussion should identify the time estimated for transit dependent residents to prepare and then travel to a bus yes Sect 6.7; means of travel to pick up points not pickup point, and describes the expected means of travel to addressed. Transportation Assistance phone numbers the pickup point.

provided for the public.

f.

The number of bus stops and time needed to load passengers should be discussed.

yes Sect 6.7

g.

A map of bus routes should be included.

N/A Existing plans do not include bus routes.

h.

The trip generation time for non-ambulatory persons includes the time to mobilize ambulances or special yes Sect 5.3 and Section 6.7 vehicles, time to drive to the home of residents, loading time,

.P

Criterion Addressed in Comments ETE Analysis (Yes/No) and time to drive out of the EPZ should be provided.

i.

Information should be provided to support analysis of return yes Sect 6.7 trips, if necessary.

4.1.3 Special Facilities

a. Information on evacuation logistics and mobilization times should be provided, yes Sect 6.7
b. Discussion should be provided on the inbound and outbound yes Sect 6.7 speeds.
c. The number of wheelchair and bed-bound individuals should be provided, and the logistics of evacuating these residents yes Sect 6.7 and Table A-6 should be discussed.
d. Time for loading of residents should be provided, yes Sect 6.7
e. Information should be provided that indicates whether the evacuation can be completed in a single trip or if additional yes Sect 3.6 and Sect 6.7 (return trips not required) trips are needed.
f.

If return trips are needed, the destination of vehicles should N/A Return trips are not anticipated.

be provided.

g. Discussion should be provided on whether special facility residents are expected to pass through the reception center yes Sect 5.4.3 prior to being evacuated to their final destination.
h. Supporting information should be provided to quantify the time elements for the return trips, yes Sect 6.7.

4.1.4 Schools

a. Information on evacuation logistics and mobilization times should be provided, yes Sect 6.7
b. Discussion should be provided on the inbound and outbound yes Sect 6.7 speeds.
c. Time for loading of students should be provided, yes Sect 6.7
d.

Information should be provided that indicates whether the evacuation can be completed in a single trip or if additional yes Sect 3.6 and Sect 6.7 (return trips not required) trips are needed.

e. If return trips are needed, the destination of school buses N/A Section 6.7 should be provided.

N/ASection_6.7

f.

If used, reception centers should be identified. Discussion should be provided on whether students are expected to yes Sect 5.4.3 pass through the reception center prior to being evacuated 91 00

Criterion Addressed in Comments ETE Analysis (Yes/No) to their final destination.

g. Supporting information should be provided to quantify the N/A Section 6.7 Return trips are not anticipated.

time elements for the return trips.

NAScin67Rtrtipaenoatcptd 4.2 ETE Modeling

a. General information about the model should be provided yes Sect 5.5 and demonstrates its use in ETE studies.
b.

If a traffic simulation model is not used to conduct the ETE calculation, sufficient detail should be provided to validate N/A Traffic simulation model used.

the analytical approach used. All criteria elements should have been met, as appropriate.

4.2.1 Traffic Simulation Model Input

a. Traffic simulation model assumptions and a representative Sect 5.5 set of model inputs should be provided.

yes

b. A glossary of terms should be provided for the key performance measures and parameters used in the yes page v analysis.

4.2.2 Traffic Simulation Model Output

a. A discussion regarding whether the traffic simulation model used must be in equilibration prior to calculating the ETE yes Sect 5.5 should be provided.
b. The minimum following model outputs should be provided to support review:

yes Sect 6, Table 7-1,Appendix C and Appendix D

1. Total volume and percent by hour at each EPZ exit mode.
2.

Network wide average travel time.

3.

Longest Queue length for the 10 intersections with the highest traffic volume.

4.

Total vehicles exiting the network.

5.

A plot that provides both the mobilization curve and evacuation curve identifying the cumulative percentage of evacuees who have mobilized and exited the EPZ.

6. Average speed for each major evacuation route that exits the EPZ.
c. Color coded roadway maps should be provided for various times (i.e., at 2, 4, 6 hrs., etc.) during a full EPZ evacuation yes Appendix D scenario, identifying areas where long queues exist including level of service (LOS) "E" and LOS "F" conditions, w

Co

Criterion Addressed in Comments ETE Analysis (Yes/No) if they occur.

4.3 Evacuation Time Estimates for the General Public

a. The ETE should include the time to evacuate 90% and 100% of the total permanent resident and transient yes Table 6-1 and Table 6-2 population.
b. The ETE for 100% of the general public should include all members of the general public. Any reductions or truncated yes Table 6-1 and Table 6-2 data should be explained.
c. Tables should be provided for the 90 and 100 percent ETEs similar to Table 4-3, "ETEs for Staged Evacuation Keyhole,"

yes Table 6-3 of NUREG/CR-7002.

d. ETEs should be provided for the 100 percent evacuation of Sect 6, Table 6-5 and Table 6-6 special facilities, transit dependent, and school po pulations.

yes 5.0 Other Considerations 5.1 Development of Traffic Control Plans

a. Information that responsible authorities have approved the traffic control plan used in the analysis should be provided, yes Sect 7
b. A discussion of adjustments or additions to the traffic control yes Sect 7 plan that affect the ETE should be provided.

5.2 Enhancements in Evacuation Time

a. The results of assessments for improvement of evacuation time should be provided, yes Sect 7
b. A statement or discussion regarding presentation of enhancements to local authorities should be provided.

5.3 State and Local Review

a. A list of agencies contacted and the extent of interaction with yes Sect 2.2 these agencies should be discussed.
b.

Information should be provided on any unresolved issues that may affect the ETE.

yes No unresolved issues.

5.4 Reviews and Updates

a. A discussion of when an updated ETE analysis is required to es Sect 6.5 be performed and submitted to the NRC.

y 5.5 Reception Centers and Congregate Care Center

a. A map of congregate care centers and reception centers should be provided.

yes Receiving communities are shown in Figure 4-1

b.

If return trips are required, assumptions used to estimate N/A Return trips are not anticipated.

C

'.*,retumtlimes for budses sh~oud,lbe provided,_______________________________

oC

-j*,t*Ishou.!

be "leetysttdy

.l If it I. ass,.umed t.hat passngers

.. e iieft-at recption. cen*rand are taken by separate yes Sect 3.1.2

.b'ses t6tho tcongregate carecenter,.

Technical Reviewer

  • --,'-J 4

,,.*--.! *.,r, Date ZýQtoV Date Supervisory. Review LALe%4

Byron Station Evacuation Time Estimates I

ARCADIS Infrastructure Water Environment Buildings Imagine the result Evacuation Time Estimates for Byron Generating Station Plume Exposure Pathway Emergency Planning Zone Prepared for Exelon Generation Warrenville, Illinois Prepared by:

ARCADIS U.S., Inc.

1 Executive Drive Suite 303 Chelmsford Massachusetts 01824 Tel 978.937.9999 Fax 978.937.7555 Our Ref.:

B0033739.0001 Date:

I August 2013

ARCADIS Executive Summary Executive Summary This report documents the Evacuation Time Estimate (ETE) study prepared by ARCADIS for the Byron Generating Station (BGS) in rural Ogle County, Illinois, about 4 miles south of I the city of Byron, and 5 miles northeast of Oregon, Illinois. The study reflects the current definition of the Emergency Planning Zone, which is the region within a nominal 10-mile distance of BGS. The most recent previous study of evacuation time estimates for Byron Station was performed in 2003. The present study was performed using population data from the 2010 census.

PTV VisionTM software was used to perform evacuation modeling for different scenarios.

The PTV Vision traffic simulation software package includes VISUM (macroscopic traffic simulation) and VISSIM (microscopic traffic simulation). VISUM is a comprehensive, flexible software system for transportation planning, travel demand modeling, and network data management. VISSIM is capable of performing detailed microscopic simulation of traffic and can model any type of traffic signal control and geometric configuration.

The road network used in the evacuation simulations consists of designated evacuation routes plus any additional roadways needed to accurately simulate conditions during an evacuation. Roadway capacities were determined using NAVTEQ TM digital data, updated by ARCADIS based on actual road and intersection data collected in the field in 2011.

Evacuees were generally assumed to proceed out of the Emergency Planning Zone (EPZ) via recommended evacuation routes and to make their way to designated reception centers after leaving the EPZ.

The EPZ for BGS includes parts of two counties in Illinois (Ogle and Winnebago).

The resident population of the Byron EPZ is estimated at 29,241 permanent residents. Based on housing data from the 2010 U.S. Census, there are fewer than 200 estimated seasonal (summer) residents in the EPZ. The 2010 U.S. Census data at block level was used to determine population in each EPZ Sub-Area.

The transient population, which includes larger workplaces, recreational facilities, and motels, was estimated at 3,314 persons for a winter weekday and 11,543 persons for a summer weekend. The special facilities population, including nursing homes and hospitals, was estimated at 508 persons for weekday scenarios. The estimated population of schools and day care centers for a winter weekday is 6,048, including children and staff. These population estimates include intrinsic double counting, as some persons in the transient and special facility populations are also included in the permanent and seasonal resident counts. Thus, evacuation times using these population figures are considered conservative.

E-1 I

Q ARCADIS Executive Summary Vehicle demand for the resident population was developed based on estimated vehicle occupancy, using data obtained from a telephone survey of EPZ residents. The vehicle occupancy factor estimated from survey responses is 1.81 persons per vehicle, which represents 1.41 vehicles per household. For the 2003 study, vehicle occupancy was 2.62 persons per vehicle (one vehicle per household).

Vehicle demand for the transient population was estimated using vehicle occupancy factors ranging from 1.0 person per vehicle for the workforce population up to 3.0 persons per vehicle for some recreational areas. Vehicle demand for the school population was based on bus occupancy of 55 students. For nursing homes, vehicle occupancy is 20 persons per bus or van for residents, and two persons per ambulance for non-ambulatory patients. For nights and weekends, all facility staff would accompany patients; during weekdays, one vehicle per person was assigned for additional staff.

Total vehicle demand for all population categories ranges from 17,152 (winter weeknight) to 21,607 (summer weekday).

Vehicle demand was also assigned to account for the potential "shadow evacuation" of the population residing immediately outside the EPZ, to a distance of 15 miles. The permanent resident population within this region is 34,491. It was assumed that 20% of the population in this region would evacuate. The occupancy factor for EPZ residents (1.81 persons per vehicle) was applied to estimate vehicle demand for this population. Shadow evacuees residing outside the EPZ add vehicle demand of 3,811 vehicles.

Evacuation times were estimated for evacuation of the entire EPZ for winter weekday (daytime and evening), winter weekend day, summer weekday (daytime and evening), and summer weekend cases under fair weather conditions. The weekday daytime cases were also evaluated for adverse weather conditions (snow and rain, respectively, for winter and summer).

A series of "staged evacuation" scenarios were also evaluated. Under a staged scenario, only the population within the 2-mile zones closest to BGS would evacuate initially; evacuation of surrounding zones would be initiated after most traffic from the 2-mile zones has cleared. The purpose of this scenario is to assess the potential reduction in evacuation times that might be achieved for the population at greatest risk.

Simulations were also performed to assess the potential impact of population growth on predicted evacuation times. This sensitivity analysis is used to define a threshold population figure that would trigger another ETE update study.

Predicted ETEs for the general population in the EPZ are summarized by scenario and distance in Table E-1 (times for 90% and 100% of vehicles to depart, for 2-mile zones, all zones to 5 miles, and all zones to 10 miles). The pattern of evacuation times is consistent E-2

V2 ARCADIS Executive Summary with the differences in vehicle demand and travel time for different scenarios. The 2-mile zone involves the shortest travel distance and the fewest vehicles; 90% ETEs for the 2-mile zone range from 2:25 to 3:55, and 100% ETEs are 4:00 to 6:20. The times are longest for summer weekday and winter weekday scenarios with adverse weather.

For all zones out to 5 miles, the 90% ETEs are 2:50 to 4:10, and the 100% ETEs are 4:20 to 6:30. For the full EPZ, the 90% ETEs are 3:15 to 4:25, while the 100% ETEs are 5:00 to 7:20.

All of these times are indicative of significant delays related to traffic congestion. The differences in vehicle demand between scenarios are up to 30% of total demand, and the predicted ETEs vary by up to 50%. Adverse weather adds up to 85 minutes for the summer weekday ETEs, and up to 95 minutes for the winter weekday ETEs.

Table E-1: Evacuation Time Estimate Summary for Byron Station EPZ Summer Winter Mde WeIe d

E gee Weekend Evening Daytim Da__cytnime Eveinytime IDaytime Scenario:

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

Weather: Normal Adverse Normal Normal Normal Adverse Normal Normal Area 90% Evacuation Time 2-mile Zone 2:50 3:30 2:35 2:35 2:40 3:55 2:25 2:30 5-mile Zone 3:15 3:45 3:00 3:00 3:25 4:10 2:50 2:55 10-mile EPZ 3:35 4:05 3:30 3:15 3:40 4:25 3:30 3:35 100% Evacuation Time 2-mile Zone 4:20 5:45 4:00 4:20 4:45 6:20 4:15 4:20 5-mile Zone 5:15 6:05 4:35 4:30 5:20 6:30 4:20 4:20 10-mile EPZ 6:15 7:00 5:30 5:25 6:15 7:20 5:10 5:00 E-3

ARCADIS Table of Contents

1. Introduction 1-1 1.1 General 1-1 1.2 Site Location and Emergency Planning Zone (EPZ) 1-2 1.3 Designated Reception Centers 1-3 1.4 Overview of Changes from Previous ETE Study 1-4
2.

Methodology and Assumptions 2-1 2.1 Sources of Data and General Assumptions 2-1 2.2 Interaction with Agencies 2-4 2.3 Summary of Methodology for Traffic Simulation 2-4 2.4 Conditions Modeled 2-5 2.4.1 Week Day 2-5 2.4.2 Week Night 2-6 2.4.3 Weekend 2-6 2.4.4 Special Event Consideration 2-7 2.4.5 Sensitivity to Population Growth and Roadway Impact 2-7

3.

Population and Vehicle Demand Estimation 3-1 3.1 Permanent Residents 3-1 3.1.1 Auto-Owning Permanent Population 3-2 3.1.2 Transit-Dependent Permanent Population 3-2 3.2 Seasonal Residents 3-3 3.3 Transient Population 3-3 3.4 Special Facilities Population 3-5 3.4.1 Medical, Nursing Care and Correctional Facilities 3-5 3.4.2 Schools and Day Care 3-5 3.5 Emergency Response Planning Area Population Totals 3-6 3.6 Transportation Resources 3-6

4. Evacuation Roadway Network 4-1 4.1 Network Definition 4-1 4.2 Evacuation Route Descriptions 4-1

ARCADIS Table of Contents 4.3 Characterizing the Evacuation Network 4-1

5.

Evacuation Time Estimate Methodology 5-1 5.1 Evacuation Analysis Cases 5-1 5.2 Initial Notification 5-2 5.3 Transportation Dependent Population 5-3 5.4 Evacuation Preparation Times and Departure Distributions 5-3 5.4.1 Permanent and Seasonal Population 5-3 5.4.2 Transient Population 5-4 5.4.3 Special Facilities 5-4 5.5 Evacuation Simulation 5-5 5.5.1 General Structure 5-6 5.5.2 Simulation Process 5-7

6.

Analysis of Evacuation Times 6-1 6.1 Evacuation Time Estimate Summary 6-1 6.2 Comparison with Previous Study 6-1 6.3 Keyhole Evacuation Scenarios 6-1 6.4 Staged Evacuation Scenarios 6-2 6.5 Sensitivity to Population Growth and Roadway Impact 6-2 6.5.1 Population Growth 6-2 6.5.2 Roadway Impact 6-3 6.6 Performance Metrics for Simulation Model 6-4 6.7 ETE for Transit Dependent, Special Facilities and Schools 6-4

7.

Traffic Control and Evacuation Confirmation 7-1 7.1 General 7-1 7.2 Evacuation Access Control Locations 7-1 7.3 Traffic Management Locations and Tactics to Facilitate Evacuation 7-1

8.

References 8-1 ii

ARCADIS Table of Contents Tables Table E-1: Evacuation Time Estimate Summary for Byron Station EPZ E-3 Table 1-1: Permanent Resident Population in the Byron Station EPZ 1-7 Table 1-2: Designated Reception Centers for Evacuation 1-8 Table 1-3: ETE Comparison 1-9 Table 3-1: Resident Population and Vehicle Demand by EPZ Subarea 3-7 Table 3-2: Transient Population and Vehicle Demand within the Byron Station EPZ 3-8 Table 3-3: Population and Vehicle Demand for Schools and Special Facilities in the Byron Station EPZ 3-9 Table 3-4: Summary of Population and Vehicle Demand within the Byron Station EPZ 3-10 Table 3-5: Summary of Transportation Resources 3-11 Table 4-1: Byron Station EPZ Primary Evacuation Routes Out of EPZ 4-3 Table 5-1: Potential Evacuation Areas for Byron Station EPZ 5-2 Table 6-1: Evacuation Time Estimate Summary for Byron Station EPZ 6-6 Table 6-2: Evacuation Time Estimates for Partial EPZ Scenarios (unstaged) 6-7 Table 6-3: Evacuation Time Estimates for Partial EPZ Scenarios (staged) 6-10 Table 6-4: Summary of Network Performance (Full 10-mile EPZ, Winter Weekday, Normal Weather) 6-17 Table 6-5: ETE for Special Facilities, Byron Station EPZ (Full 10-mile EPZ, Winter Weekday, Normal Weather) 6-18 Table 6-6: ETE for Schools and Daycares in Byron Station EPZ (Full 10-mile EPZ, Winter Weekday, Normal Weather) 6-19 Table 7-1: Predicted Queuing at Major Intersections (Full 10-mile EPZ, Winter Weekday, Normal Weather) 7-2 iii

ARCADIS Table of Contents Figures Figure 1-1.Byron Generating Station EPZ Area 1-5 Figure 1-2.Resident Population by Sector within 15 Miles of Byron Generating Station 1-6 Figure 4-1.Designated Evacuation Routes for Byron Generating Station EPZ 4-4 Figure 5-1. Departure Time Distributions for the Byron Station EPZ 5-5 Figure 5-2.Evacuation Modeling and Simulation using PTV Vision Suite 5-6 Figure 6-1. Departure Curves for Stage 2 Zones, Byron Station EPZ 6-11 Figure 6-2. Byron Sensitivity of ETE to Population Growth (Summer Weekday, Normal Weather, Full EPZ) 6-12 Figure 6-3. Byron Predicted Traffic Volume by Link with Full Network (Summer Weekday, Normal Weather, Full EPZ) 6-13 Figure 6-4. Byron Predicted Traffic Volume by Link with IL 72 Westbound Link Removed (Summer Weekday, Normal Weather, Full EPZ) 6-14 Figure 6-5. Time Distribution of Vehicles on the Network (Full 10-mile EPZ, Winter Weekday, Normal Weather) 6-15 Figure 6-6. Comparison of Vehicle Mobilization and Departure Rates (total vehicles 22,307) 6-16 Appendices A

Transient and Special Facility Population Data B

Telephone Survey of EPZ Residents C

Roadway Network Map and Data Table D

Maps Depicting Travel Speed along Road Network (winter day, fair weather, full EPZ) iv

V2 ARCADIS List of Acronyms and Abbreviations Table of Contents ADT Average daily traffic BAO ESRI Business Analyst Online BGS Byron Generating Station EAS Emergency Alert System EPZ Exposure Pathway Emergency Planning Zone ERPA Emergency Response Protection Area ETE Evacuation time estimate GIS Geographic information system GPS Global Positioning System IEMA Illinois Emergency Management Agency IPRA Illinois Parks and Recreation Association LOS Level-of-service NRC Nuclear Regulatory Commission PAR Protective Action Recommendation TAR Tone alert radios WC Wheelchair v

Exelon Generation C2 ARCADIS Byron Station Evacuation Time Estimates

1. Introduction 1.1 General Evacuation time studies analyze the manner in which the population within the Plume Exposure Pathway Emergency Planning Zone (EPZ) surrounding a nuclear power plant site would evacuate during a radiological emergency. Evacuation time studies provide licensees and State and local governments with site-specific information helpful for protective action decision-making. The studies estimate the time necessary to evacuate the EPZ for a range of evacuation scenarios. Analysis of the evacuation simulation results also identifies locations where traffic management and control measures can facilitate the evacuation, and may identify unique evacuation constraints or conditions.

Estimates of the time required to evacuate from areas around nuclear power plant sites are required for all operating plants in the United States. Federal guidance has been prepared to outline the format and content of these evacuation time estimates (NUREG-0654, Rev. 1 (Nuclear Regulatory Commission (NRC), 1980), NUREG/CR-4831 (NRC, 1992) and NUREG/CR-7002 (NRC, 2011)).

Evacuation time estimate (ETE) studies were last updated for the Byron Generating Station (BGS) Plume Exposure Pathway EPZ in 2003 (Earth Tech, 2003). The guidance presented in NUREG/CR-7002 indicates that the evacuation time estimates should be updated as local conditions change, but at least once each decade, following release of the federal census. The current update study was prompted by the issuance of revised ETE guidance (CR-7002) and the availability of population data from the 2010 census.

Census data indicate that the population residing within the EPZ for BGS increased by I 2,145 between 2000 and 2010, which represents a 7.9% population increase. (Population data are discussed further below in section 1.4.)

The evacuation time estimates have been developed using current population, local roadway network characteristics and the PTV VisionTM traffic simulation software package to perform evacuation modeling for different scenarios. PTV Vision includes the VISSIM (microscopic traffic simulation) and VISUM (macroscopic traffic simulation) models.

Evacuation times have been estimated for various areas, times and weather conditions, as outlined in CR-7002. These evacuation times represent the times required for completing the following actions:

0 Public notification; 1-1

Exelon Generation V2 ARCADIS Byron Station Evacuation Time Estimates Preparation and mobilization; and Actual movement out of the EPZ (i.e., on-road travel time, including delays associated with vehicle queuing).

1.2 Site Location and Emergency Planning Zone (EPZ)

This report describes the analyses undertaken, and the results obtained, in a study to update the existing Evacuation Time Estimates for BGS. The emergency response plan is designed to protect the health and safety of the public in the event that an evacuation is ordered as a protective action in response to an accident at BGS.

BGS is located in Rockvale Township, Ogle County, Illinois, about 4 miles south of Byron, Illinois and 15 miles southwest of Rockford, Illinois. The plant location is shown in Figure 1-1.

The plume exposure pathway emergency planning zone (EPZ) is the geographic area surrounding a nuclear power plant within which the NRC requires advance planning for evacuation or other short-term protective actions in the event of a radiological emergency.

The Byron Station EPZ consists of the area within an approximate 10-mile radius of BGS.

The EPZ includes part of two counties (Ogle and Winnebago). The Byron Station EPZ is subdivided into a total of 12 Sub-Areas, or Emergency Response Protection Areas (ERPAs). These ERPAs are the basic units for which protective action recommendations are issued. Sub-Area boundaries often follow geographic (township) boundaries, and reflect distance and direction from BGS. The distance ranges of concern are 0-2 miles, 2-5 miles, and beyond 5 miles. EPZ and ERPA boundaries are shown in Figure 1-1.

Most of the EPZ area is in Ogle County. Only ERPAs 39 and 40, on the north side of the EPZ, are in Winnebago County. Each of the ERPAs in Ogle County is an entire township.

The ERPAs are described in more detail in Section 3.

A listing of the 2010 permanent resident population by ERPA within the Byron Station EPZ is shown in Figure 1-1. Table 1-1 compares the EPZ population from the 2010 and the 2000 census. The EPZ population of 29,241 residents is concentrated in several villages and small cities (Byron, Oregon, Mount Morris, and Davis Junction). ERPA 17, which includes the city of Byron, has the largest population (6,563). Five ERPAs each contain more than 10% of the resident population.

The population residing in the EPZ grew by 2,145 between 2000 and 2010, an increase I of 7.9%. ERPA 27 gained 1,510 residents, an increase of 90%. ERPAs 17 and 23 each 1-2

Exelon Generation V2 ARCADIS Byron Station Evacuation Time Estimates I grew by 12%. The rest of the EPZ experienced a small net loss, with small gains or losses in individual ERPAs.

The Rock River crosses the EPZ from southwest to northeast, generally parallel to Highway 2. The area within 2 miles of BGS is rural in character. ERPA 19, which contains BGS, has 1,770 residents; most of those live near Byron, about 4 miles from the plant.

NRC guidance also requires consideration of potential "shadow evacuation" of the population residing immediately outside the EPZ, to a distance of 15 miles.

The permanent resident population in the region surrounding the EPZ within 15 miles of BGS is 34,491. Most of this population resides in the city of Rockford, Illinois (pop. 152,871),

located northeast of BGS in Winnebago County. Shadow evacuees residing outside the EPZ add vehicle demand of 3,811 vehicles. A map showing the population by distance and direction sector within 15 miles of Byron Station is provided in Figure 1-2. (Due to roundoff errors that propagate when sector boundaries cut across census block boundaries, the population numbers disagree slightly between Figure 1-1 and Figure 1-2.

Figure 1-1 is more accurate for the EPZ population.)

1.3 Designated Reception Centers The Byron Station emergency response evacuation plan directs residents of communities within the EPZ to evacuate to specified reception centers. If evacuation is initiated while schools are in session, students will be transported directly to designated reception centers, and families are instructed to meet up with the students at those locations.

The designated receiving communities for ERPAs within the Byron Station EPZ are Rockford, Freeport and Dixon, Illinois. The preferred reception community for each ERPA is listed in Table 1-2. (Some ERPAs may evacuate differently, depending upon the prevailing wind direction.) The roadway network used to develop evacuation time estimates includes the major roadways recommended to the public as evacuation routes from individual communities to designated reception centers. The roadway network is designed to utilize all available major roadways, with traffic flow directed radially outward from BGS toward the EPZ boundaries. The roadway network is described in detail in Section 4.

1-3

Exelon Generation ARCADIS Byron Station Evacuation Time Estimates 1.4 Overview of Changes from Previous ETE Study The changes in residential population within the EPZ are summarized in Table 1-1. The revised NRC guidance and newly acquired data led to a number of other changes in the ETE methodology and assumptions. Table 1-3 provides a summary comparing the main features and assumptions of the current study to the 2003 ETE study. The telephone survey of EPZ residents provides a new basis for estimating vehicle occupancy and departure times, while new NRC guidance has specified different assumptions regarding background and "shadow" traffic. The ETE methodology and assumptions for the current study are discussed in greater detail in following sections of the report.

The revised vehicle occupancy for residents (1.81 persons per vehicle, based on survey),

revised departure times for schools and special facilities (no "early warning") and the revised departure time curves for residents (based on survey responses and estimated time for warning diffusion) are expected to have the greatest influence on estimated evacuation times. The "shadow evacuation" adds vehicle demand of 3,811 vehicles in the area immediately outside the EPZ. The potential impacts of shadow evacuation will be greatest for travel to the Rockford reception center. Each of these issues is discussed in more detail in following sections of the report.

1-4

EXELO GENEATIO

EPZ EPZ 3,442

  • t.OUT 5

OUT 4,3 TOT..

T11 TO I7 1130 2034 1821 Ou 122 03 15 OUT

1. 01 EI EP 38 0

5 51 36 7

504

.TOT.

OU ~

7 5 2 7 160 1

f60 3471 20 24 4109 52 35 425 01402 201 Legend O2.292' W10 Seto 15-il so Secto Direct..on DISTANCE POPULATION DISTANCE POPULATION EPZ-1 83 NA EPZ-2 403 NA EPZ-3 677 NA EPZ-4 3,384 NA EPZ-5 6,110 NA EPZ-6 5,223 NA EPZ-7 1,642 NA EPZ-8 3,475 NA EPZ-9 2,556 NA EPZ-10 2,983 OUT-10 318 EPZ-11 1,623 OUT-11 628 EPZ-12 741 OUT-12 2,021 EPZ-13 219 OUT-13 5,151 EPZ-14 74 OUT-14 9,798 EPZ-15 24 OUT-15 16,599 EPZ-15+

I NA EPZ TOTAL:

29,2181 EPZ-15 TOTAL:

34,515 TOTAL POPULATION: 63,733 NOTE:

" EPZ total population varies from 2011 draft report totals by less than1 % due to the rounding of population calculations from additional block processing.

" Plant to 1 mile population not summarized in any sector direction Open Ster Map e*e Im-ge Source Ar04S 0

Serive, 00esA date: MM/15002, We JS02 0.11 TMe unse m nette re-eats or dltrtbr,000r e

ftee 0

u0seo of Bee POP.

V ARCADIS PlOPD* LtIONs Dth IBU7O0N EZ&SECTORS 15-MILE

ARCADIS Exelon Generation Byron Station Evacuation Time Estimates Table 1-1: Permanent Resident Population in the Byron Station EPZ ERPA Loca Communities (towniship, ciy village)

Census Cess ecnt Ogle County 19 (0 - 5 mi)

Rockvale Township 1,748 1,770 1.3 23 (0 - 5mi)

Marion Township, Stillman Valley 3,671 4,135 12.6 17 (2 - 10 mi)

Byron Township, Byron 5,840 6,563 12.4 20 (2 - 10 mi)

Oregon-Nashua Township, Oregon 5,310 4,909

-7.6 25 (2 - 10 mi)

Pine Rock Township 979 985 0.6 10 (5 - 10 mi)

Leaf River Township, Leaf River 1,260 1,137

-9.8 12 (5 - 10 mi)

Mount Morris Township, Mount Morris 4,065 3,968

-2.4 14 (5 - 10 mi)

Pine Creek Township 719 758 5.4 27 (5 - 10 mi)

Scott Township, Davis Junction 1,671 3,181 90.4 28 (5 - 10 mi)

White Rock Township, Kings 709 738 4.1 Winnebago County 39 (5 - 10 mi)

Seward Twp (part), Winnebago Twp (part) 616 591

-4.1 40 (5 - 10 mi)

Rockford Township (part) 508 506

-0.4 Byron Station EPZ Total 27,096 29,241 7.9 %

Sources: a) 2000 census data from 2003 ETE study report b) 2010 census data (block level) 1-7

Q ARCADIS Exelon Generation Byron Station Evacuation Time Estimates Table 1-2: Designated Reception Centers for Evacuation I

ERPA9 Ree-iving Community 19 (0 - 5 mi)

Dixon, Rockford, or Freeport.

23 (0 -1mi)

Dixon, Rockford, or Freeport.

17 (2 - 10 mi)

Rockford or Freeport.

20 (2 - 10 mi)

Dixon.

25 (2 - 10 mi)

Dixon.

10 (5 - 10 mi)

Freeport.

12 (5 - 10 mi)

Dixon or Freeport.

14 (5 - 10 mi)

Dixon.

27 (5 - 10 mi)

Rockford.

28 (5 - 10 mi)

Rockford or Dixon.

39 (5-10 mi)

Rockford.

40 (5-10 mi)

Rockford or Freeport.

1-8

14 ARCADIS Exelon Generation Byron Station Evacuation Time Estimates Table 1-3: ETE Comparison ETE Element 2003 ETE Current Study Permanent Residents

- Total population

- 27,096

- 29,241 Vehicle occupancy

- 2.62 (one vehicle per

- 1.81 (persons per vehicle) household)

Transit dependent Evacuation of transit dependent

- Population estimate population was not addressed in

- 450 persons, 142 non-ambulatory

- Number of buses 2003 study

- 16 bus

- Number of ambulances

- 5 ambulances, 44 wheelchair vans Transient facilities (winter day/summer weekend)

(winter day/summer weekend)

- Estimated population

- 5,465/14,670

- 3,314/11,543

- Vehicle demand

- 4,124/7,557

- 2,478/4,640

- Adjust for double-count - No adjustment

- Some adjustment Special facilities (winter weekday)

(winter weekday)

- Estimated population

- 715 508 (including staff)

- Number bus, van

- 14 bus/van

- 16 bus/van

- Ambulance, other

- 18 ambulance 7 ambulances, 7 wheelchair vans Schools (winter weekday)

(winter weekday)

- Number of buses

- 6,656 (day care included)

- 6,048 (day care included)

- 140 bus/van

- 90 bus/11 van Background traffic None Average traffic by time of day Shadow evacuation None 20% of resident population outside (assumed basis) designated zones Special Event(s)

None None Scenarios

- Winter day, winter night

- Weekday (winter, summer)

- Summer day, summer night

- Weeknight (winter, summer)

- Both normal and adverse

- Weekend (winter, summer) weather for all four cases

- Adverse weather weekday only

- Staged evacuation (weekday)

Adverse Weather Snow for winter, rain for summer Snow for winter, rain for summer Evacuation Model name NetVac2 PTV Vision VISUM 11.5, VISSIM 5.3 and version Departure times

- Residential based on literature

- Warning based on literature

- Transient based on literature

- Residential based on survey

- Specials based on notification at - Transient based on survey alert

- Specials notified with public Evacuation times Estimates provided primarily for Estimates provided for 90 and 100%

100%

1-9

Exelon Generation Va ARCADIS Byron Station Evacuation Time Estimates

2. Methodology and Assumptions 2.1 Sources of Data and General Assumptions The following data sources were reviewed and assumptions made in order to develop the appropriate population and roadway databases used for the evacuation analysis:

Population estimates for permanent residents were developed from 2010 U.S.

Census Bureau data.

Population estimates for seasonal residents were developed from 2010 United States Census Bureau data on housing units. Census data identify the number of seasonal housing units (vacant housing units for "seasonal or occasional use") at different geographic levels (e.g., by township, census tract, block group, block). A conservative estimate of seasonal population was developed by assigning six persons per seasonal housing unit.

Population estimates for major employers were developed from ESRI list and the facility list from the 2003 study report. ARCADIS conducted internet searches and telephone surveys to estimate facility employment and staffing levels for different scenarios. Only facilities with potential staffing level of at least 50 persons per work shift were pursued.

Information relating to hotels, motels and recreational facilities was obtained from tourism websites, 2011 AAA TourBook listings, and the 2003 study report. For parks, visitation information was obtained from state park agencies.

Current population estimates for schools were obtained primarily from county emergency response agencies, plus enrollment information available on the internet.

Lists of hospitals, rest homes and incarceration facilities were obtained from each county emergency management agency.

The staffing levels at BGS reflect estimated peak personnel onsite during outage conditions. These data were provided by Exelon Generation.

2-1

Exelon Generation V2 ARCADIS Byron Station Evacuation Time Estimates Initial estimates of roadway characteristics were obtained from the NAVTEQ database. Roadway geometric and operational data were compiled based on field surveys performed by ARCADIS in 2011.

" Average traffic volumes by time of day for weekday and weekend for designated evacuation routes were obtained from state and county transportation agencies.

These data were used to assign background traffic volumes for the roadway network. It was assumed that access control would be established within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> following the public notice to evacuate.

" Preparation and mobilization times for the permanent resident population were developed based on the results of a telephone survey, combined with published time estimates for warning diffusion. The survey provided estimates of the time to depart from home following notification, and commuting times for household members who would return from work before departing. Median departure times for residents are longer than the times assumed in the previous study.

" Departure times for transient facilities were estimated assuming relatively prompt evacuation of most workplaces and recreational facilities once notification is received. The distribution of departure times also reflects information gathered from the telephone survey of EPZ residents, as discussed in Section 3.

  • The evacuation time estimates represent the time required to evacuate the Byron Station EPZ and designated analysis areas and include the time required for initial notification.

I Evacuation time estimates are presented for 90% and 100% of evacuating vehicles. It is assumed that all persons within the EPZ area will evacuate. For the 100% evacuation time, evacuation of the EPZ will be considered complete after all evacuating vehicles are outside of the EPZ or analysis area.

The general public will evacuate using designated evacuation routes and will proceed to the reception centers listed in Table 1-2 after leaving the EPZ. When schools are in session, children attending school will be transported directly to designated reception centers.

It is assumed that existing lane utilization will prevail during the course of the evacuation.

Traffic control signals will be over-ridden or converted to flashing mode as necessary to give preference to flow on all major outbound roadways. It 2-2

Exelon Generation ARCADIS Byron Station Evacuation Time Estimates is also assumed that State and municipal personnel will restrict unauthorized access into the EPZ, consistent with existing traffic management plans.

The evacuation analysis cases are described in Section 2.3 and represent a range of conditions, per guidance presented in CR-7002.

These cases have been chosen to provide information for an appropriate range of conditions (i.e., low, typical and high population; fair and adverse weather) to guide the protective action decision-making process.

Potential "special events" such as holiday parades and sporting events occurring within the EPZ were considered, based on input from state and county agencies. None of these events was judged to represent a major departure from the peak traffic assumptions reflected in the "standard" scenarios, so a Special Event scenario was not included in this study.

Vehicle occupancy rates used for the various population categories are as follows:

Permanent residents - 1.81 persons per vehicle, based on telephone survey results Major places of employment - 1 vehicle per employee.

Motels - 1 vehicle (1 to 2 persons) per occupied room.

Recreational areas -

1 vehicle (3 persons) per campsite; 1.5 persons per vehicle at visitor centers and museums.

Schools - 55 students and 3 staff per bus; one vehicle per additional staff person.

Hospitals/Nursing Homes/Correctional Facilities - 2 persons per ambulance or 3 per wheelchair (WC) van for non-ambulatory patients, and 20 people per bus or van for ambulatory residents.

Transit-dependent residents - 20 persons per bus or van; for non-ambulatory, 3 per WC van and 2 per ambulance.

The transit-dependent population will be evacuated by bus or ambulance through efforts coordinated by state and municipal emergency preparedness officials.

2-3

Exelon Generation V2 ARCADIS Byron Station Evacuation Time Estimates Adverse weather refers to moderate to heavy rainstorms for summer conditions, and a moderate snowstorm for winter conditions.

2.2 Interaction with Agencies Emergency management agencies responsible for planning and implementing the emergency response procedures during a radiological emergency were consulted during the development of this ETE study.

The Illinois Emergency Management Agency (IEMA) and emergency agencies for Ogle and Winnebago Counties were contacted to obtain information regarding special and transient facilities in the EPZ, transportation resources available to evacuate special facilities, and the transit dependent general public. Those agencies were also consulted to identify any major events that take place within the EPZ that should be considered for a Special Event scenario The Illinois Parks and Recreation Association (IPRA) list of special and transient facilities for all six Exelon nuclear stations in Illinois was provided to ARCADIS by Exelon. IEMA and the county agencies reviewed the draft report and the facility databases used in this study.

Representative background traffic volumes for the EPZ roadway network were obtained from state and county transportation agencies.

2.3 Summary of Methodology for Traffic Simulation The evacuation time estimates developed for the Byron Station EPZ are based upon a time distribution of evacuation events as opposed to a summation of sequential events.

This methodology assumes that the various time components in an evacuation (i.e.,

the time associated with preparation, mobilization, etc.) overlap and occur within certain time ranges. The time distribution approach is based upon assumptions consistent with the NRC guidance of CR-7002.

Trip generation times are used to develop vehicle loading curves for different population types within the permanent, transient, and special facility populations. A trip generation time consists of two main components: warning diffusion time and mobilization time. Warning diffusion time is the time it takes for people to receive an emergency notification. The type of warning systems employed in the EPZ, such as emergency alert system (EAS), sirens, and tone alert radios (TARs) affects the distribution of warning times. Availability of more warning systems leads to faster warning diffusion to the public.

2-4

Exelon Generation

$ ARCADIS Byron Station Evacuation Time Estimates Mobilization time is the time between the receipt of notification and when individuals leave for evacuation. Mobilization time depends on the type of population and activity.

Warning diffusion time and mobilization time distributions are used to develop composite loading distribution or trip generation curves for different population segments. Trip generation times for transit dependent facilities, special facilities and schools were developed separately from those for the general public.

2.4 Conditions Modeled Pursuant to the guidance in CR-7002 and NUREG-0654, Rev. 1, evacuation time estimates have been prepared for a range of temporal, seasonal and weather conditions.

Estimates have been prepared for weekday, weeknight and weekend scenarios during winter and summer. All scenarios are simulated with fair weather conditions; weekday scenarios are also simulated assuming adverse weather. Fair weather refers to conditions where roadways are clear and dry, and visibility is not impaired.

Adverse weather during summer periods is defined as heavy rain, with impaired visibility; roadway capacities are reduced by 10% and speeds are reduced by 15%. Adverse weather during winter periods is defined as a snowstorm condition where roadway capacities and speeds are reduced by 15%.

The various population components which have been incorporated in the evacuation scenarios are summarized below:

2.4.1 Week Day This situation represents a typical weekday period with the work force is at a full daytime level.

During winter, schools are in session. Vehicle demand estimates for weekday scenarios reflect the following conditions:

Most permanent residents within the EPZ will evacuate from their places of residence; Major work places are fully staffed at typical daytime levels; BGS employment is at an estimated peak daytime level, representative of operation during outage conditions; Schools and daycares are at current enrollment; 2-5

Exelon Generation V2 ARCADIS Byron Station Evacuation Time Estimates Hospitals and nursing homes are at current enrollment or typical occupancy;

" Motel facilities are occupied at peak (winter or summer) levels; and Recreational facilities are at winter or summer weekday levels.

2.4.2 Week Night This situation reflects a typical night period when most permanent residents are home and the work force is at evening shift level. Assumptions on the population levels for this condition include the following:

Permanent residents within the EPZ will evacuate from their places of residence; Major work places are at typical evening levels; BGS employment is at an estimated peak night-time level; Day schools and daycares are closed; Hospitals and nursing homes are at current enrollment or typical occupancy, and staffing is at typical night-time levels; Motel facilities are occupied at (winter or summer) weekday levels; and Recreational facilities are at typical (winter or summer) evening levels.

2.4.3 Weekend The weekend scenario represents a daytime period when most residents are at home and major work places are at typical weekend levels. Assumptions on the population levels for this condition include the following:

Residents within the EPZ will evacuate from their places of residence; Major work places are at typical weekend levels; Day schools and daycares are closed; 2-6

Exelon Generation C ARCADIS Byron Station Evacuation Time Estimates Hospitals and nursing homes are occupied and staffed at weekend levels; Motel facilities are occupied at weekend (winter or summer) levels; and Recreational facilities are at (winter or summer) weekend levels.

2.4.4 Special Event Consideration County agencies and IEMA were asked to identify events such as a county fair or Fourth of July observance that would bring a large number of visitors into the EPZ. No events were identified that are large enough to pose a significant challenge for an emergency evacuation, so a Special Event scenario was not developed for the Byron EPZ. (The same decision was made for the 2003 update study.)

2.4.5 Sensitivity to Population Growth and Roadway Impact Additional scenarios were evaluated to assess the sensitivity of ETEs to population growth and roadway impact. These sensitivity cases used the Summer Weekday, Normal Weather case for the Full EPZ as the base case. The population growth analysis is used to determine how rapidly the ETE would increase as the resident population in the EPZ is increased.

For the roadway impact scenario, a major evacuation route is removed or reduced in capacity.

Specifically, one of the five highest volume roadways is removed from service, or capacity is reduced by one lane (for a multi-lane, limited-access roadway such as an interstate highway). A more detailed description of the sensitivity analysis is provided in Section 6.5.

2-7

Exelon Generation ARCADIS Byron Station Evacuation Time Estimates

3. Population and Vehicle Demand Estimation The development of vehicle demand estimates for the Byron Station EPZ consisted of two primary steps. The first step was the determination of the number and distribution of the population to be evacuated. The second step was the determination of the appropriate number of vehicles for each of the population categories.

Federal guidance (CR-7002) indicates that three population categories should be considered:

permanent residents, transients, and persons in schools and special facilities (such as medical facilities/ nursing homes, and day care facilities).

The methodology used to develop the total population and vehicle demand estimates within the Byron Station EPZ incorporates intrinsic double counting. For example, a portion of the identified employees and visitors to recreational areas are also permanent residents within the EPZ. In addition, school children are counted in the resident population, but are also counted in the special facility population.

While population and vehicle demand estimates incorporate some adjustments for double-counting, the estimates are considered to be conservative (i.e., they over-estimate actual population and vehicle levels which may be in the area at any given time).

Population and vehicle demand estimates for each of the population categories are summarized below.

3.1 Permanent Residents Permanent residents are those persons identified by the census as having a permanent residence within the EPZ. The Census 2010 population data for census tracts, block groups and blocks were used to determine the permanent resident population within the EPZ and within each municipality and Sub-Area. The allocation of the resident population to entry nodes on the roadway network was based on detailed census block maps.

An estimated 29,241 persons reside permanently within the Byron Station EPZ.

Table 3-1 presents the resident population and vehicle demand by Sub-Area.

The EPZ Sub-Areas are defined based on distance and direction from BGS, and generally follow geographic (township) boundaries.

ERPA 19 (Rockvale Township) contains BGS. This ERPA extends 6 miles west of BGS and 3 miles north and south. ERPA 23 (Marion Township extends 6 miles to the east, 3 miles to the south, and almost 10 miles northeast of BGS. The village of Stillman Valley is in ERPA 23. ERPA 17 (Byron Township) extends from 3 miles north to 9 miles north of BGS. ERPA 17 contains the city of Byron and has the largest resident population in the EPZ. ERPA 20 (Oregon-Nashua Township) extends from 3 miles to 10 miles SSW of BGS. ERPA 20 contains 3-1

Exelon Generation V ARCADIS Byron Station Evacuation Time Estimates the city of Oregon. ERPA 25 and ERPA 28 extend to 10 miles southeast of BGS.

ERPA 27 contains Davis Junction and extends from 6 miles to 10 miles east of BGS.

On the western side of the EPZ, ERPAs 10, 12 and 14 extend to 10 miles distance.

The city of Mount Morris is in ERPA 12, and the village of Leaf River is in ERPA 10.

On the north side of the EPZ, ERPAs 39 and 40 in Winnebago County extend from 8 to 10 miles distance from BGS.

A telephone survey of EPZ residents was conducted to obtain information relating to how many vehicles residents would use to evacuate and how long it would take them to depart following notification. The survey questionnaire and results are provided in Appendix B.

3.1.1 Auto-Owning Permanent Population Vehicle demand associated with the permanent resident population was estimated based on telephone survey responses. After adjusting survey results to reflect the age distribution of the EPZ, the estimated occupancy factor is 1.81 persons per vehicle, which corresponds to 1.41 vehicles per household. Total vehicle demand for EPZ I residents for all scenarios is 16,155. "Shadow evacuation" of 20% of the population residing outside the EPZ within 15 miles of BGS adds vehicle demand of another 3,811 vehicles.

For the 2003 ETE study, evacuation times were determined for vehicle demand assumption of one vehicle per household, or 2.62 persons per vehicle, for permanent residents.

3.1.2 Transit-Dependent Permanent Population Emergency response plans specify that the transit-dependent population will receive transportation assistance. Provisions for evacuating transit-dependent members of the general population in Illinois do not rely on published pickup points and bus routes.

County emergency response planners maintain lists of residences (self-identified) requiring transportation assistance. For ETE analysis, the estimated size of the transit-dependent population in each EPZ was based on NRC guidance and results of the telephone survey. That population size is much higher than the number who have self-identified in advance. Based on telephone survey results, less than 2% of households (with phones) had either no vehicle or no licensed driver. NRC guidance (CR-7002) indicates that roughly half of households without vehicles available would evacuate with neighbors, friends or relatives, which would leave less than 1% needing assistance from the county. NRC guidance also indicates that between 1.5 and 5% of 3-2

Exelon Generation ARCADIS Byron Station Evacuation Time Estimates residents may require transportation. For this study, ETE estimates were based on 1.5%

of residents, which represents about 450 transit-dependent residents.

Approximately 142 of these individuals will require a WC van or ambulance to evacuate, based on data provided by Ogle County. Estimated vehicle needs for transit-dependent residents are based on 20 persons per bus, 3 non-ambulatory residents per WC bus or van, and 2 per ambulance.

Individuals requiring transit from reception centers to congregate care centers will be transported in a separate set of vehicles from those designated to transport the transit dependent and special facilities out of the EPZ.

3.2 Seasonal Residents The seasonal population category addresses those who reside in the EPZ on a temporary basis, particularly during the summer period.

The 2010 U.S. Census of Population and Housing reports the number of vacant households classified as "for seasonal or occasional use". Census data identified less than 50 such housing units in the Byron Station EPZ, and less than 10 in any ERPA. These low numbers indicate that the number of seasonal residents in the Byron EPZ is not significant, relative to the permanent resident population.

3.3 Transient Population The transient population segment includes persons in the work force, hotels/motels, and recreational areas. Regional maps and mapping software were used to determine facility locations and assign entry nodes. Significant employers within the EPZ were identified using ESRI Business Analyst Online (BAO). BAO is a web-based analytical and mapping tool that facilitates location-specific queries about business and demographic data. Data available on BAO includes information on business location and number of employees. ESRI extracts business data from a comprehensive list of businesses (over 12 million U.S. businesses) licensed from Infogroup. ARCADIS used BAO to search for all employers with 50 or more employees located within an 11-mile radius of BGS. CR-7002 recommends consideration of "large employers" with 50 or more employees on a single shift.

The list from BAO was screened to eliminate businesses where workers do not remain on-site (e.g., transportation and trucking companies, construction, realtors, home health care).

Employment at schools and special facilities (e.g., hospitals, nursing homes) is generally tracked as part of the special facilities database. The reduced list was then reviewed to exclude facilities located outside the EPZ, and to determine the 3-3

Exelon Generation ARCADIS Byron Station Evacuation Time Estimates ERPA for those located in the EPZ. The new list of employers was compared to the list from the 2003 study and the IPRA Special Facilities list provided by IEMA.

Telephone calls were made to selected large employers to verify employment numbers and to estimate staffing levels during weekday, weeknight and weekend periods. The results from those calls confirmed that BAO listings provided accurate locations and current, reliable employment numbers for most establishments. Workforce numbers for BGS were provided by Exelon Generation and reflect the peak work force during outage conditions.

Numbers of units and campsites for motels and recreational areas were obtained from the TripAdvisor website, the 2011 AAA TourBook for Illinois, and from state and county tourism websites. Seasonal occupancy was estimated based on capacity figures (e.g.,

number of campsites) and a telephone survey of selected facilities. State and local parks agencies also provided visitation numbers for parks and campgrounds.

For purposes of estimating the total number of vehicles associated with the transient population segment, an occupancy factor of 1.0 employee per vehicle was used for most work places. For the hotel/motel and recreational populations, it was assumed that there would be 1.0 vehicle (1.5 or 2 persons) per hotel/motel unit, and 1.0 vehicle (3 to 4 persons) per campsite. For parks, visitation numbers were generally obtained as numbers of vehicles, and an occupancy factor of 3.0 persons per vehicle was assumed. For museums and visitor centers, 1.5 persons per vehicle was assumed.

Campgrounds were assumed to be fully occupied during summer.

Motels were assumed to be fully occupied for all scenarios.

Vehicle demand was reduced for selected recreation facilities in consideration of double-counting. Local residents represent a substantial portion of attendance at these facilities, and it was assumed that many residents would return home before evacuating the EPZ.

Table 3-2 presents a summary of the transient population by Sub-Area for each scenario. The transient population and associated vehicle demand are greatest for summer weekday and summer weekend scenarios. Recreation facilities are located primarily along the Rock River (ERPA 17, 19, 20, 23) and in ERPA 14.

For the summer weekday scenario, the two ERPAs with highest population and vehicle demand from transient facilities are 12 and 19, reflecting a combination of employers and recreation facilities.

For the summer weekend scenario, the two ERPAs with highest population and vehicle demand are 14 and 23, reflecting the dominant impact of recreation facilities. Population data and vehicle demand estimates for the transient 3-4

Exelon Generation ARCADIS Byron Station Evacuation Time Estimates population segment, including the work force, hotels and motels, and recreational areas are presented by facility in Appendix A. A breakdown of population by distance and direction sectors was not developed for transient and special facilities, since state and county agencies rely on population by ERPAs for emergency response planning.

3.4 Special Facilities Population The special facility population segment includes persons in schools, hospitals, nursing homes and correctional facilities who will require transportation assistance during an evacuation. Most of these facilities are located in ERPAs with cities (12, 17, 20, 23).

The special facilities population is summarized by ERPA in Table 3-3; data by facility is provided in Appendix A.

3.4.1 Medical, Nursing Care and Correctional Facilities One healthcare center, two nursing homes and two assisted living facilities are located in the EPZ. Vehicle occupancy for nursing home patients is two non-ambulatory patients and one staff per ambulance, three non-ambulatory patients and one staff per WC bus, and 20 residents or patients plus 2 staff per vehicle (bus or van) for ambulatory patients, plus one vehicle per staff person who does not evacuate with patients.

3.4.2 Schools and Day Care Thirteen public schools and six pre-school/daycare facilities have been identified within the Byron Station EPZ, with a total population of 6,048 students and staff. None of the identified schools is residential, so students are only present on weekdays during the school year.

Vehicle occupancy for public schools is based on 58 persons (55 students, 3 staff) per bus, plus one vehicle per additional school staff.

Student population for public schools was determined from state-published enrollment information.

Six licensed child care (large daycare) facilities were identified in the EPZ, with an estimated daytime population of 252. Facilities were identified from internet listing of licensed childcare establishments. The population estimates represent the licensed capacity of each facility. Smaller home-based daycare facilities (capacity 10 or less) were not tabulated; those facilities contribute little vehicle demand beyond that assigned to EPZ residents.

3-5

Exelon Generation V ARCADIS Byron Station Evacuation Time Estimates 3.5 Emergency Response Planning Area Population Totals Population and vehicle demand totals for each Sub-Area are summarized in Table 3-4.

The totals listed in the table represent the peak number of people to be evacuated for each analysis case discussed in Section 6 of this report.

Vehicle demand is highest for the summer weekday scenario. Vehicle demand for the highest (summer weekday) scenario is almost 30% higher than the lowest (winter weekend) scenario.

ERPA 17, which includes the city of Byron, has the largest population and vehicle demand for all scenarios. The vehicle demand listed in Tables 3-2, 3-3 and 3-4 reflects the data used as input for the ETE traffic simulations.

3.6 Transportation Resources The estimated inventory of transportation resources available to support evacuation of special facilities and residents for the Byron EPZ was determined from information provided by county agencies, plus data developed by surveying school systems, transportation companies and EMS providers in the surrounding region. Identified transportation resources are summarized and compared to estimated vehicle demand in Table 3-5. The number of available vehicles in each category (bus, WC bus or van, ambulance) is more than sufficient to evacuate facilities and EPZ residents in a single wave. Buses and vans available within Ogle County are sufficient, but WC bus/van and ambulance resources from metropolitan Rockford in Winnebago County will be needed to evacuate non-ambulatory residents.

3-6

ARCADIS Exelon Generation Byron Station Evacuation Time Estimates Table 3-1: Resident Population and Vehicle Demand by EPZ Subarea Permanent Vehicle Sub-Area Distance Resident Population Demand 10 10 miles 1,137 628 12 10 miles 3,968 2,192 14 10 miles 758 419 17 5 miles 6,563 3,626 19 2 and 5 miles 1,770 978 20 5 and 10 miles 4,909 2,712 23 2 and 5 miles 4,135 2,285 25 5 and 10 miles 985 544 27 10 miles 3,181 1,757 28 10 miles 738 408 39 10 miles 591 327 40 10 miles 506 280 EPZ Total 29,241 16,155 3-7

ARCADIS Exelon Generation Byron Station Evacuation Time Estimates Table 3-2: Transient Population and Vehicle Demand within the Byron Station EPZ PoDulation Veicles Sub-Area Day Night~ Weekend...

Day_ Night Weekend Day Night Weekend Day.

Nlaht Weekend 10 0

0 0

0 0

0 0

0 0

0 0

0 12 196 60 48 370 144 252 166 30 18 232 36 104 14 320 285 455 2,290 1,835 2,715 170 135 203 887 672 1,031 17 638 296 340 1,750 1,186 1,839 546 216 179 903 472 683 19 812 288 538 2,070 1,254 1,902 660 246 286 1,215 659 880 20 955 476 330 1,490 722 970 698 248 123 937 350 401 23 285 140 680 1,910 985 3,330 154 44 285 814 360 1,328 25 40 0

40 120 75 150 16 0

16 48 30 60 27 68 12 0

68 12 0

68 12 0

68 12 0

28 0

0 0

300 300 385 0

0 0

120 120 154 39 0

0 0

0 0

0 0

0 0

0 0

0 40 0

0 0

0 0

0 0

0 0

0 0

0 EPZtotal 3,314 1,557 2,431 10,368 6,513 11,543 2,478 931 1,110 5,223 2,711 4,640 3-8

0 ARCADIS Exelon Generation Byron Station Evacuation Time Estimates Table 3-3: Population and Vehicle Demand for Schools and Special Facilities in the Byron Station EPZ PODulation Vehicles Sub-Area Winter Summer Winter Summer Day Night Weekend Day Night Weekend Day Night Weekend Day Night Weekend 10 0

0 0

0 0

0 0

0 0

0 0

0 12 565 153 153 262 153 153 172 24 24 122 24 24 14 0

0 0

0 0

0 0

0 0

0 0

0 17 2,132 105 105 142 105 105 373 20 20 42 20 20 19 0

0 0

0 0

0 0

0 0

0 0

0 20 1,841 108 108 268 108 108 318 22 22 59 22 22 23 1,777 0

0 38 0

0 292 0

0 5

0 0

25 91 0

0 0

0 0

52 0

0 0

0 0

27 0

0 0

0 0

0 0

0 0

0 0

0 28 151 0

0 0

0 0

25 0

0 0

0 0

39 0

0 0

0 0

0 0

0 0

0 0

0 40 0

0 0

0 0

0 0

0 0

0 0

0 EPZ total 6,556 366 366 710 366 366 1,231 66 66 228 66 66 3-9

Q ARCADIS Exelon Generation Byron Station Evacuation Time Estimates Table 3-4: Summary of Population and Vehicle Demand within the Byron Station EPZ Population Vehicles Sub-Area Winter Summer Winter Summer Day Night Weekend Day Night Weekend Day Night Weekend Day Night Weekend 10 1,137 1,137 1,137 1,137 1,137 1,137 628 628 628 628 628 628 12 4,729 4,181 4,169 4,600 4,265 4,373 2,530 2,246 2,234 2,546 2,252 2,320 14 1,078 1,043 1,213 3,048 2,593 3,473 589 554 622 1,305 1,090 1,449 17 9,333 6,964 7,008 8,455 7,854 8,507 4,545 3,862 3,824 4,571 4,118 4,329 19 2,582 2,058 2,308 3,840 3,024 3,672 1,638 1,224 1,264 2,193 1,637 1,858 20 7,705 5,493 5,347 6,667 5,739 5,987 3,728 2,982 2,857 3,708 3,084 3,135 23 6,197 4,275 4,815 6,083 5,120 7,465 2,731 2,329 2,570 3,103 2,645 3,613 25 1,116 985 1,025 1,105 1,060 1,135 612 544 560 592 574 604 27 3,249 3,193 3,181 3,249 3,193 3,181 1,825 1,769 1,757 1,825 1,769 1,757 28 889 738 738 1,038 1,038 1,123 433 408 408 528 528 562 39 591 591 591 591 591 591 327 327 327 327 327 327 40 506 506 506 506 506 506 280 280 280 280 280 280 EPZtotal 39,111 31,164 32,038 40,319 36,120 41,150 19,864 17,152 17,331 21,607 18,932 20,862 Population numbers reflect some double-counting between categories (residents, workforce, schools, etc.).

3-10

Q ARCADIS Exelon Generation Byron Station Evacuation Time Estimates Table 3-5: Summary of Transportation Resources County Bus Van WC Bus* van Ambulance Ogle 174 25 20 8

Winnebago 340 55 60 20 Total Available 514 80 80 28 Identified Vehicle Need Schools and Day Care 90 11 Special Facilities 16 7

7 Transit-Dependent Public 16 44 5

Total Identified Need 106 27 51 12 3-11

ARCADIS Exelon Generation Byron Station Evacuation Time Estimates

4.

Evacuation Roadway Network 4.1 Network Definition In order to estimate evacuation times for the Byron Station EPZ, an evaluation of the roadway network likely to be used by departing vehicles was undertaken. ARCADIS relied on several sources of information to define the evacuation roadway network:

Evacuation routes described in the existing State emergency response plan; Maps of highways and local roadways for the EPZ area; and A field survey of the roadways in the Byron Station EPZ.

The primary evacuation routings used in the modeling are indicated in Figure 4.1.

4.2 Evacuation Route Descriptions The evacuation routings were developed to simulate travel out of the EPZ using available roadways. The network relies primarily on the evacuation routings depicted in the public information brochure. Descriptions of the primary evacuation routes for different geographic areas within the EPZ are outlined in Table 4-1.

4.3 Characterizing the Evacuation Network Roadway characteristics such as roadway class, number of lanes, lane and shoulder width, speed limit, lane configuration near intersections, and traffic control are key factors in determining how fast an evacuation can be completed. These roadway attributes control roadway capacity, which in turn governs operating traffic conditions measured in terms of level-of-service (LOS). LOS is measured from A to F for roadway segments and intersections. LOS A represents free-flow conditions, and LOS F represents force or breakdown flow conditions.

ARCADIS used NAVTEQTM roadway data with detailed information, including local streets, to build the evacuation roadway network for the study. NAVTEQ data was imported into geographic information system (GIS) software (ESRI ArcGISTM) for conducting field surveys to verify evacuation roadway segment attributes. The information provided in the public information brochure for the site was used to highlight evacuation routes in GIS. ARCADIS has developed an integrated GIS-Global 4-1

ARCADIS Exelon Generation Byron Station Evacuation Time Estimates Positioning System (GPS) tool that allows field personnel to record observations in an efficient and effective manner. The evacuation network, including traffic controls, was verified to a 15-mile radius from the plant, and along designated routes to the receptions centers. Once the NAVTEQ data was verified through the field survey, the evacuation roadway network was transferred to the traffic simulation software VISUM for modeling different evacuation scenarios.

Having accurate traffic control information is important to accurately estimate evacuation times because intersections have potential to create bottleneck points.

During an evacuation scenario, intersections might be manually controlled by officials, operated with existing traffic signal timing plans, or adjusted according to changing I vehicular demand. In general, the emergency response plans for Byron Station call for signal override, i.e., signals set to flashing to give priority to outbound travel on designated evacuation routes.

Traffic control information is coded as part of the evacuation network database.

Background and pass-through traffic in the EPZ could account for significant number of vehicles and could influence evacuation depending on the direction of travel. As recommended in CR-7002, average daily traffic (ADT) volumes, representative of typical background levels, were obtained from state and county transportation agencies.

During the simulations, background traffic will be included during the initial I 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of the evacuation scenario, up to the time when access control is established to prevent vehicles from entering the EPZ.

A map of the evacuation network showing node numbers and links, as recommended by the latest guidance, is provided in Appendix C. Detailed attributes of each roadway segment, such as link number, number of lanes, speed limit, length, and roadway type are also tabulated in Appendix C, and traffic controls are listed for each intersection.

4-2

0 ARCADIS Exelon Generation Byron Station Evacuation Time Estimates Table 4-1: Byron Station EPZ Primary Evacuation Routes Out of EPZ EPZ SubAreas Evacuation Rou4tes IL 2 South to Dixon; 19 (0 - 5 mi)

IL 2 North to Rockford; IL 72 West to IL 26 North to Freeport.

IL 2 South to Dixon; 23 (0 - 5mi)

IL 2 North to Rockford; IL 72 West to IL 26 North to Freeport.

IL 2 North to Rockford; IL 72 West to IL 26 North to Freeport.

20 (2-10 mi)

IL 2 South or IL 38 West to Dixon.

25 (2 - 10 mi)

IL 38 West to Dixon.

10 (5-10 mi)

IL 72 West to IL 26 North to Freeport.

IL 64 West to IL 26 South to Dixon; IL 64 West to IL 26 North to Freeport.

14 (5 - 10 mi)

IL 2 South or IL 26 South to Dixon.

27 (5 - 10 mi)

IL 251 North to Rockford.

IL 251 North to Rockford; IL 251 South to IL 38 West to Dixon.

39 (5 - 10 mi)

IL 251 North to Rockford.

Edwardsville Road East to Rockford; U.S. 20 West to Freeport.

4-3

Legend X

Station Location Reception Community Emergency Evacuation Route m ERPA Division Interstate & US Highways Major Roads Minor Roads 5

10 W

I w

ARCADIS Locatien I

BYRON GENERATING STATION EVACUATION-I ROAD WAY NET W.ORK PSO U w~.

E~.

w.D.~2Q~2aYRONE,.~nRo.dwyN.t.* n~d U ~

ý:

U lpn*,d&WaabVýJAWVAý%DwMI21BYRONEýrýRoodway_ý.md U:W.*ý1E..k.e40.0.-0,M12

ARCADIS Exelon Generation Byron Station Evacuation Time Estimates

5. Evacuation Time Estimate Methodology 5.1 Evacuation Analysis Cases Time estimates have been prepared for a general evacuation scenario for each of these analysis cases:

Winter Weekday, Fair Weather and Adverse Weather Conditions Winter Weeknight, Fair Weather Conditions Winter Weekend, Fair Weather Conditions Summer Weekday, Fair Weather and Adverse Weather Conditions Summer Weeknight, Fair Weather Conditions Summer Weekend, Fair Weather Conditions Areas for evacuation are selected based on the "keyhole" configuration (0-2 mile zone plus 2-5 mile or 0-5 mile plus 5-10 mile downwind zone). The partial-EPZ evacuation areas for BGS are reproduced in Table 5-1, based on the Protective Action Recommendation (PAR) chart. Separate simulations may not be necessary for each of the areas listed in Table 5-1. ETE estimates will generally be controlled by whether one or two critical Sub-Areas (e.g., ERPA 7) are included.

Enough cases will be run to ensure that representative ETE estimates are obtained for all potential scenarios.

For all partial-EPZ evacuation cases, "shadow" vehicle demand (20% of residents) is assigned to all Sub-Areas which are not included in the evacuation region, in addition to the region outside of the EPZ.

5-1

ARCADIS Exelon Generation Byron Station Evacuation Time Estimates Table 5-1: Potential Evacuation Areas for Byron Station EPZ Wind Direction (from)

EPZ Sub-Areas 2-mile radius & 5 miles downwind WD 008 to 068 deg 19,20,23 WD 069 to 128 deg 19,23 WD 129 to 227 deg 17, 19,23 WD 228 to 288 deg 19,23 WD 289 to 345 deg 19,23,25 WD 346 to 007 deg 19, 20, 23, 25 5-mile radius & 10 miles downwind WD 022 to 051 deg 14,17,19, 20, 23, 25 WD 052 to 082 deg 12,14,17,19, 20,23, 25 WD 083 to 100 deg 12,17,19, 20, 23, 25 WD 101 to 125 deg 10,12,17,19,20,23,25 WD 126 to 139 deg 10,17,19,20,23,25 WD 140 to 171 deg 10,17,19,20,23,25,40 WD 172 to 209 deg 17,19,20,23,25,40 WD 210 to 220 deg 17,19,20,23,25,39,40 WD 221 to 248 deg 17,19,20,23,25,27,39 WD 249 to 264 deg 17,19, 20, 23, 25, 27 WD 265 to 285 deg 17,19, 20, 23, 25, 27, 28 WD 286 to 326 deg 17,19, 20, 23, 25, 28 WD 327 to 021 deg 17,19,20,23,25 Entire EPZ All 5.2 Initial Notification The EPZ surrounding BGS has an outdoor siren notification system consistent with the requirements of NUREG-0654, Rev. 1/FEMA-REP-1 Appendix 3. This system will be used by state and local officials to alert the population to turn on their radios and television sets. Pursuant to NUREG 0654, Rev. 1 guidance, notification messages will commence on the designated television and Emergency Alert System (EAS) radio stations concurrent with sounding of the sirens. Within 15 minutes of alert notification, essentially all of the population within the EPZ will begin to receive an informational or instructional message. If evacuation is deemed necessary, the timing of the order to evacuate and notification measures will be controlled by the state and local emergency preparedness officials. Those officials may choose to alert and mobilize an emergency response work force to control and expedite evacuation prior to the evacuation order.

5-2

C2 ARCADIS Exelon Generation Byron Station Evacuation Time Estimates 5.3 Transportation Dependent Population The transportation dependent population includes individuals without access to transportation, as well as those requiring special transportation assistance.

Transportation dependent persons will be notified of a protective action recommendation in the same manner as the general public.

If evacuation is recommended, persons needing transportation assistance will be informed through the EAS to contact the appropriate officials for assistance. Evacuees who do not have access to transportation and confined persons who require special transportation assistance will be provided transportation by the appropriate agency.

5.4 Evacuation Preparation Times and Departure Distributions It is assumed that no vehicles will begin to evacuate during the 15-minute initial notification period. Accordingly, in the model simulations, vehicles will begin to evacuate at 15 minutes following the initial notification. After the initial 15-minute time period, vehicles are loaded at a linear rate over each 5-minute time interval, in accordance with the network loading distributions for each population type.

For example, if 2% of 2,500 vehicles (50 vehicles) are to be loaded at a specific location over a 5-minute period, PTV Vision will load 10 vehicles per minute at that location during the specified interval.

Network loading distribution assumptions for the permanent population, transient population, and special facilities are based on the anticipated response of different population sectors to an evacuation order.

Mobilization times for residents and workers reflect the data acquired by the telephone survey of EPZ residents, and are consistent with published data from actual historical events (ORNL, 1990). Loading distributions are explained below, and summarized in Figure 5-1.

5.4.1 Permanent and Seasonal Population Permanent and seasonal residents with access to automobiles will take varying amounts of time to begin evacuating. Some persons will leave as quickly as possible; most will take some time to prepare, pack valuables and clothes and then depart; some will take added time to secure property before departing; and some may require transportation assistance.

In addition, actual departure and preparation times may vary according to the perceived severity of a particular evacuation order.

Based upon these factors, it was assumed that there would be a period of up to 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> over which the permanent residents would begin to evacuate.

That is, permanent 5-3

ARCADIS Exelon Generation Byron Station Evacuation Time Estimates resident households would begin to evacuate between 15 and 180 minutes after the decision to notify the population to evacuate is made. Based on estimated waming diffusion and survey results from EPZ residents, during a weekday, 50% would depart within 75 minutes, 90% within 110 minutes, and 99% within 180 minutes. At night, with most household members at home, 50% would depart within 60 minutes, 90% within 95 minutes, and 99% within 165 minutes. These time profiles are generally consistent with observed behavior during evacuations for chemical releases.

5.4.2 Transient Population It was assumed that the work force would be subject to the same warning diffusion as the general public. Based on estimated warning diffusion and survey results from EPZ residents, it was estimated that 50% of the work force would evacuate within 40 minutes following the decision to evacuate, 90% within 65 minutes, and 99% within 105 minutes. For a few facilities, it may be necessary for a limited number of workers to remain on the job in order to safely shut down processes, secure the facility or maintain essential operations. The evacuation time estimates do not address those workers who remain behind, since there is no reliable basis for predicting whether or how soon they will evacuate. The assumption that all workers evacuate provides a conservative estimate of vehicle demand. Discussions with emergency preparedness officials indicate that the same time distribution is also reasonable for the other transient population categories within the EPZ, including motels and recreation areas.

5.4.3 Special Facilities It was assumed that special facilities (i.e., schools, nursing homes) within the EPZ would also receive initial notification promptly.

Based upon data obtained from previous studies, vehicle departure times were developed that reflect a distribution of notification, preparation and mobilization times.

Consistent with the current off-site emergency response plans, the schools will be evacuated via bus to the designated reception center using the same evacuation routes as the public. For school facilities, it was assumed that up to 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> may be required to assemble buses, transport vehicles to schools and to load students onto buses. Vehicles stationed at the facilities at the time of the ordered evacuation could I be loaded in as little as 15 minutes following notification. Accordingly, 50% of school buses depart onto the evacuation network during the period between 15 and 75 I minutes, 90% by 135 minutes, and 99% by 180 minutes. The school profile was also applied for daycare facilities.

5-4

ARCADIS Exelon Generation Byron Station Evacuation Time Estimates I Evacuation of special facilities (nursing homes and hospitals) would also require additional time associated with preparation and transport of vehicles to the respective I facilities. Those special facilities will evacuate directly to designated host facilities.

Based upon previous studies, it was assumed that these facilities would begin to evacuate between 30 minutes and 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> following notification. The first 50% will depart within 90 minutes, 90% within 150 minutes, and 99% within 165 minutes.

Departure times - Byron EPZ t'U 0.8 0.8 resident day C

0 0.6 resident night Z

oZ--worker 4.4

-schools E 0.2/

-special

-transit depend 0

50 100 150 200 time (minutes)

Figure 5-1.

Departure Time Distributions for the Byron Station EPZ 5.5 Evacuation Simulation Traffic simulation provides the ability to analyze evacuation of an area in great detail. In most traffic simulation models, there are two main inputs: supply (roadway) network data and demand (population and vehicular) data. Traffic models use different types of algorithms to predict traffic flow and provide measures of effectiveness (MOEs) such as average travel times, total number of vehicles exiting the system, and queue lengths at various times and points.

5-5

ARCADIS Exelon Generation Byron Station Evacuation Time Estimates 5.5.1 General Structure ARCADIS used PTV Vision to perform evacuation modeling for different scenarios.

The PTV Vision traffic simulation software package includes VISSIM (microscopic traffic simulation) and VISUM (macroscopic traffic simulation). VISUM is a comprehensive, flexible software system for transportation planning, travel demand modeling, and network data management. VISSIM is capable of performing detailed microscopic simulation of traffic, public transport, and pedestrian simulations, and can model any type of traffic control and geometric configuration. Both VISUM and VISSIM are capable of performing multi-modal analysis including car, commercial vehicle, bus, train, motorcycles, bicycles, and pedestrians. The two programs work together seamlessly, saving valuable time and resources.

I

-Verified Evacuation Network

  • OD Matrices
  • Traffic Demand Volumes I
  • Trael Times

' Queue Lengths

" Bottlenecks Figure 5-2.

Evacuation Modeling and Simulation using PTV Vision Suite VISUM was used to develop the evacuation network and population entry nodes (centroids). One of the key features of VISUM is its ability to interact seamlessly with GIS-data such as ESRI ArcGIS database. The field verified evacuation network data and demand data developed in ArcGIS were imported directly into VISUM. Origin-I Destination trip tables were developed for the evacuation and imported into VISUM.

VISUM software was then used to route the Origin-Destination information on the network using a dynamic equilibrium algorithm. This algorithm ensured that traffic levels on the network were realistic given the capacities available on individual links.

Once an initial solution was found in VISUM, the information was exported into VISSIM for microsimulation. A microsimulation was deemed a necessary step in order to obtain 5-6

ARCADIS Exelon Generation Byron Station Evacuation Time Estimates detailed and realistic results on queuing and average travel times. VISSIM can model intersection with different type of traffic control such as yield signs, stop signs, and signals. VISSIM also provides a better understating of critical and congested part of the network.

5.5.2 Simulation Process The ETE results include the time to evacuate 90% and 100% of the total permanent and transient population. Based on the current guidance, ETEs for special facilities, schools, and the transit dependent population are developed separately; only the time to evacuate 100% of these population groups was needed.

Consistent with current guidance, vehicle demand for each scenario was based on 100% of the population residing in areas designated for evacuation, plus 20% of the population residing in Sub-Areas outside the designated evacuation area, and 20% of the population residing outside of the EPZ, out to a distance of 15 miles. Vehicle demand outside of the designated evacuation area is intended to account for the impact of "shadow evacuees". A sensitivity analysis was performed to evaluate the impact of changes different input parameters and assumptions such as changes in lane closures, trip generation times, vehicular demand, evacuation routes, and background traffic.

The simulation process can be summarized as follows:

VISUM

1. Create every scenario based on
a. Background traffic
b. Time of day
c. Day of week
d. Weather condition
e. Season
f. Wind Direction
g. Shadow traffic
2. Run Dynamic Traffic Assign to and calculate Permanent and Transient, Shadow, Special Needs/Schools volumes 5-7

ARCADIS Exelon Generation Byron Station Evacuation Time Estimates

3. Assignment process will last until suitable convergence is reached. VISUM provides output on the goodness of convergence after assignment. The convergence fit is not as critical because this is an evacuation model of a no-notice event, therefore full user equilibrium cannot be expected.
4.

Export to VISSIM.

VISSIM

1. Warm-up time built into background/pass-through traffic generation.
2.

Check for any local calibration parameters.

3.

Run the final multimodal Dynamic Traffic Assignment in VISSIM to consider queues and intersection delays

4.

Sensitivity analysis and count evacuees at 2, 5, and 10 miles

5.

Prepare ETE times MOEs

1.

90% evacuation time (for all wind directions and scenarios, staged and normal evacuations)

a.

This applies to evacuation of the PUBLIC only

2.

100% evacuation time (for all wind directions and scenarios, stage and normal evacuations)

3.

Color-coded roadway map at various times (2, 4, 6 hrs) which identifies where long queues exist, including LOS E and F conditions.

5-8

Exelon Generation ARCADIS Byron Station Evacuation Time Estimates

6. Analysis of Evacuation Times 6.1 Evacuation Time Estimate Summary Predicted ETEs for the general population in the EPZ are summarized by scenario and I distance in Table 6-1 (times for 90% and 100% of vehicles to depart, for 2-mile zones, all zones to 5 miles, and all zones to 10 miles). The pattern of evacuation times is consistent with the differences in vehicle demand and travel time for different scenarios.

The 2-mile zone involves the shortest travel distance and the fewest I vehicles; 90% ETEs for the 2-mile zone range from 2:25 to 3:55, and 100% ETEs are 4:00 to 6:20. The times are longest for summer weekday and winter weekday scenarios with adverse weather.

For the 2-mile plus all 5-mile zones, the 90% ETEs are 2:50 to 4:10, and the 100%

ETEs are 4:20 to 6:30. For the full EPZ, the 90% ETEs are 3:15 to 4:25, while the 100% ETEs are 5:00 to 7:20.

All of these times are indicative of significant delays related to traffic congestion. The differences in vehicle demand between scenarios are up to 30% of total demand, and the predicted ETEs vary by up to 50%. Adverse weather adds more than an hour to the ETEs for the 2-mile zone, and more than 45 minutes to ETEs for the 5-mile zone and the full EPZ.

6.2 Comparison with Previous Study The ETEs for the current study are longer than the ETEs from the 2003 study. Vehicle demand for the full EPZ for the current study (19,864 for Winter Weekday) is about I 28% higher than vehicle demand from the 2003 study (15,542), and the new 100%

ETE (with adverse weather) is 7:00, compared to 3:50 in 2003. The current ETEs also reflect the addition of background traffic and longer departure times (based on the survey of residents).

6.3 Keyhole Evacuation Scenarios ETEs for scenarios that reflect the current range of Protective Action Recommendation (PAR) scenarios to evacuate the near-field population and selected downwind zones are summarized in Table 6-2.

These results indicate that PAR scenarios involving Sub-Area 17 (most of the city of Byron) have the longest ETEs for evacuations 6-1

Exelon Generation ARCADIS Byron Station Evacuation Time Estimates extending to 5 miles downwind.

All of the 5-mile zone and 10-mile downwind PAR scenarios have very similar ETEs.

6.4 Staged Evacuation Scenarios A series of staged evacuation scenarios were evaluated based on NRC guidance (CR-7002).

In a staged evacuation, the 2-mile zone evacuates first, while surrounding zones shelter in place; after the population has evacuated the 2-mile zone, the outer zones would be instructed to evacuate. The "stage 1" time is determined by simulating evacuation of the 2-mile zone for the Winter Weekday, Normal Weather scenario, with only background and shadow traffic in other parts of the EPZ. Once the Stage 1 time (2:40) was determined, a revised set of departure curves was developed for the outer (Stage 2) zones. The Stage 2 departure curves for Byron are shown in Figure 6-1.

The departure curves are much steeper at the beginning of Stage 2, because people are able to return home and prepare to depart during Stage 1.

Results for staged evacuation scenarios are summarized in Table 6-3. The ETEs for the staged scenarios are consistently longer than the corresponding "unstaged" ETEs, in several cases by an hour or more.

The modeled results indicate that staged evacuation for Byron would result in little or no benefit, in terms of the time required to evacuate the 2-mile zone, and significant penalty, in terms of increased ETEs for the zones which would initially be ordered to shelter.

6.5 Sensitivity to Population Growth and Roadway Impact 6.5.1 Population Growth NRC guidance (CR-7002) for updating ETE studies more frequently than the 10-year federal census includes criteria based on population growth.

Specifically, if the residential population growth in the EPZ since the last ETE update is sufficient to cause an increase in the ETE by 25% or by 30 minutes, whichever is less, then a full ETE update study must be performed.

A sensitivity analysis was performed by determining the 90% ETEs for increases of 5, 15 and 20% of the EPZ residential population for the Winter Weekday, Normal Weather scenario. This scenario produced the longest ETE by season or time of day.

The population was increased in the same manner in the surrounding region, out to 15 miles.

Results are illustrated in Figure 6-2.

With a 15% increase in residential population above the 2010 census values, the 90% ETE for the full EPZ increased to 4:10, an increase of 30 minutes.

Since the EPZ residential population for Byron 6-2

Exelon Generation ARCADIS Byron Station Evacuation Time Estimates changed by less than 8% between 2000 and 2010, it appears unlikely that an increase of 15% will occur before 2020.

The 100% ETEs increased more slowly than the 90% ETEs. With a 15% increase in population, the 100% ETE for the full EPZ increased by 20 minutes, from 6:15 to 6:35.

NRC guidance (CR-7002) indicates that emergency planning decisions should be based on the 90% ETEs. The recommended "update threshold" for the Byron EPZ, based on population growth, is therefore 15%.

6.5.2 Roadway Impact NRC guidance (CR-7002) also requires analysis of a "roadway impact" scenario. For this scenario, a major evacuation route is removed or reduced in capacity. Specifically, one of the 5 highest volume roadways is removed from service, or capacity is reduced by one lane (for a multi-lane, limited-access roadway such as an interstate highway).

This scenario is specified as Summer Weekday, Normal Weather for the Full EPZ. For Byron, the five highest-volume roadways for this scenario are listed below:

S Lowell Park Rd - 3,475 vehicles IL 72 westbound - 3,000 vehicles IL 2 northeast - 3,000 vehicles IL 2 (Oregon) - 1,900 vehicles IL 72 eastbound-1,100 vehicles Predicted traffic volumes by link for the "base case" simulation with the full roadway network are shown in Figure 6-3.

One link in the highest-volume roadway, IL 72 westbound -

west of Byron, was removed for the roadway impact scenario. The impact location is shown in Figure 6-4.

With this roadway unavailable, the ETEs increased from 3:35 (90%) and 6:15 (100%)

to 3:44 (90%) and 7:57 (100%). With IL 72 westbound unavailable, traffic is primarily rerouted through IL 2 southwest of Byron.

6-3

Exelon Generation V ARCADIS Byron Station Evacuation Time Estimates 6.6 Performance Metrics for Simulation Model The performance of VISSIM is assessed using standard metrics, consistent with the guidance provided in CR-7002.

Table 6-4 provides a summary of simulation parameters for Winter Day Normal Weather scenario for the full EPZ. Figure 6-5 illustrates the number of vehicles on the network over the course of the simulation, while Figure 6-6 compares the rate of vehicles loading onto the network to the frequency of departures.

The parameters in Table 6-4 include an average travel speed for evacuating vehicles of 22.7 miles per hour, which indicates that traffic is encountering significant congestion during much of the simulation. The average travel time of 3.43 hours4.976852e-4 days <br />0.0119 hours <br />7.109788e-5 weeks <br />1.63615e-5 months <br /> reflects travel to the designated reception centers, rather than the travel time to exit the EPZ.

6.7 ETE for Transit Dependent, Special Facilities and Schools The ETE for transit dependent members of the general public is estimated based on the assumption of a single set of bus runs from Byron, Oregon and Mt Morris. The run would begin 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> after the evacuation notice, allowing time for evacuees to prepare I and to travel (if possible) to designated pickup points. The time sequence would then proceed in the following steps:

0 55 minutes for the bus to traverse up to ten pickup points (5 miles at 20 mph = 15 minutes) and load passengers (10 stops at 4 minutes = 40 minutes).

Up to 7 miles travel at 35 mph to exit the EPZ = 12 minutes.

Total evacuation time 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> 7 minutes.

For non-ambulatory residents evacuating via WC van, a similar sequence would include mobilization (150 minutes), three pickups (each with 10 minutes loading and 4 miles travel at 20 mph, total 66 minutes), and travel out of EPZ (12 minutes, as before),

for total evacuation time of 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> 48 minutes. The added mobilization time reflects travel from Rockford into the EPZ, as noted in Section 3.1.

Estimated evacuation times for special facilities, schools and daycares located in the EPZ are summarized in Tables 6-5 and 6-6. These times are shorter than the 100%

ETEs for the general population. Facility-specific estimates are based on a three-step time sequence: (1) mobilization, (2) loading, and (3) travel out of the EPZ. Mobilization and loading times are generally the largest components. At nursing homes and 6-4

Exelon Generation V2 ARCADIS Byron Station Evacuation Time Estimates assisted living facilities, each bus or van will require about 15 minutes to load, with multiple vehicles loading simultaneously. WC vans and ambulances will require up to 30 minutes to load; estimated mobilization times are also longer for those vehicles. For school buses from within Ogle County, it will require between 90 and 120 minutes to contact drivers, provide them with instructions and deploy them to assigned schools.

Most of the students at Chana Education Center would evacuate in their own vehicles.

For travel time, average speeds were estimated for the anticipated evacuation route, based on the traffic simulation for the Winter Day scenario. The simplified stepwise methodology used to determine these estimates provides a typical evacuation time, rather than an upper bound 90% or 100% value.

6-5

C2 ARCADIS Exelon Generation Byron Station Evacuation Time Estimates I Table 6-1: Evacuation Time Estimate Summary for Byron Station EPZ Summer Winter jIMidweek Daytime Weekend Evenin jM~id yweek D

aytime Wekn vening t

0%

Daytime Dayt_________

____im Affected Scenario:

(1)

(2)

(3)

(4)

(5)

(6)

(7) j (8)

ERPAs Weather:

Normal Adverse,Normal INormal INormal Adverse Normal Normal 90% Evacuation of Affected Areas 19,23 2-mile Zone 2:50 3:30 2:35 2:35 2:40 3:55 2:25 2:30 17,19,20,23,25 5-mile Zone 3:15 3:45 3:00 3:00 3:25 4:10 2:50 2:55 ALL 10-mile EPZ 3:35 4:05 3:30 3:15 3:40 4:25 3:30 3:35 100% Evacuation of Affected Areas 19,23 2-mile Zone 4:20 5:45 4:00 4:20 4:45 6:20 4:15 4:20 17,19,20,23,25 5-mile Zone 5:15 6:05 4:35 4:30 5:20 6:30 4:20 4:20 ALL 10-mile EPZ 6:15 7:00 5:30 5:25 6:15 7:20 5:10 5:00 6-6

ARCADIS Exelon Generation Byron Station Evacuation Time Estimates Table 6-2: Evacuation Time Estimates for Partial EPZ Scenarios (unstaged)

(a) 2-mile Zone plus 5 Miles Downwind Summer Winter Midweek Daytime Weekend Daytime Evening Midweek Daytime Weekend Daytime Evening Scenario:

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

Affected ERPAst Weather:

Normal Adverse Normal Normal Normal Adverse Normal Normal 90% Evacuation of 2-mile Zone and 5 Miles Downwind 19,20,23,25 N-NNW 2:45 3:15 2:35 2:25 2:50 3:35 2:30 2:30 19,20,23 NNE-NE 2:45 3:15 2:35 2:25 2:50 3:35 2:30 2:30 19,23 ENE-ESE 3:00 3:30 2:50 2:40 2:45 3:30 2:25 2:25 17,19,23 SE-SW 3:05 3:35 2:55 2:45 3:10 3:55 2:50 2:50 19,23,25 WNW-NW 2:45 3:15 2:35 2:25 2:45 3:30 2:25 2:25 100% Evacuation of 2-mile Zone and 5 Miles Downwind 19,20,23,25 N-NNW 4:45 5:35 4:05 3:55 4:45 5:55 3:45 3:45 19,20,23 NNE-NE 4:45 5:35 4:05 3:55 4:45 5:55 3:45 3:45 19,23 ENE-ESE 4:30 5:20 3:50 3:40 4:45 5:55 3:45 3:45 17,19,23 SE-SW 5:10 6:00 4:30 4:20 5:20 6:30 4:20 4:20 19,23,25 WNW-NW 4:30 5:20 3:50 3:40 4:45 5:55 3:45 3:45 6-7

ARCADIS Exelon Generation Byron Station Evacuation Time Estimates (b) 5-mile Zone plus 10 Miles Downwind (90% ETE)

Summer Winter IMidweek Daytime Wend Evening Midweek Daytime Wend Evening Affected ERPAs Scenario:

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

Weather:

Normal I Adverse Normal Normal Normal Adverse Normal Normal 90% Evacuation of 5-mile Zone and 10 Miles Downwind 17,19,20,23,25 N

3:25 3:55 3:15 3:05 3:25 4:10 3:05 3:05 14,17,19,20,23,25 NNE 3:25 3:55 3:15 3:05 3:25 4:10 3:05 3:05 12,14,17,19,20,23,25 NE-ENE 3:25 3:55 3:15 3:05 3:25 4:10 3:05 3:05 10,12,14,17,19,20,23,25 E

3:25 3:55 3:15 3:05 3:25 4:10 3:05 3:05 10,12,17,19,20,23,25 ESE 3:25 3:55 3:15 3:05 3:20 4:05 3:00 3:00 10,12,17,19,20,23,25,40 SE 3:25 3:55 3:15 3:05 3:20 4:05 3:00 3:00 10,17,19,20,23,25,40 SSE-S 3:25 3:55 3:15 3:05 3:25 4:10 3:05 3:05 17,19,20,23,25,27,39,40 SSW-SW 3:25 3:55 3:15 3:05 3:25 4:10 3:05 3:05 17,19,20,23,25,27,28,39 WSW 3:25 3:55 3:15 3:05 3:30 4:15 3:10 3:10 17,19,20,23,25,27,28 W-WNW 3:30 4:00 3:20 3:10 3:25 4:10 3:05 3:05 17,19,20,23,25,28 NW-NNW 3:30 4:00 3:20 3:10 3:30 4:15 3:10 3:10 6-8

0 ARCADIS Exelon Generation Byron Station Evacuation Time Estimates (c) 5-mile Zone plus 10 Miles Downwind (100% ETE)

Summer Winter Midweek Daytime Weekend Evening Midweek Daytime Weekend Evening Daytime Daytime Scenario:

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

Affected ERPAs10%EautoofDyie Daim Weather:

Normal Adverse Normal Normal Normal] Adverse Normal Normal 100% Evacuation of 5-mile Zone and 10 Miles Downwind 17,19,20,23,25 N

5:45 6:35 5:05 4:55 5:50 7:00 4:50 4:50 14,17,19,20,23,25 NNE 5:45 6:35 5:05 4:55 5:45 6:55 4:45 4:45 12,14,17,19,20,23,25 NE-ENE 5:55 6:45 5:15 5:05 5:50 7:00 4:50 4:50 10,12,14,17,19,20,23,25 E

5:50 6:40 5:10 5:00 5:50 7:00 4:50 4:50 10,12,17,19,20,23,25 ESE 5:40 6:30 5:00 4:50 5:35 6:45 4:35 4:35 10,12,17,19,20,23,25,40 SE 6:00 6:50 5:20 5:10 5:35 6:45 4:35 4:35 10,17,19,20,23,25,40 SSE-S 6:05 6:55 5:25 5:15 5:45 6:55 4:45 4:45 17,19,20,23,25,27,39,40 SSW-SW 5:40 6:30 5:00 4:50 5:30 6:40 4:30 4:30 17,19,20,23,25,27,28,39 WSW 5:15 6:05 4:35 4:25 5:50 7:00 4:50 4:50 17,19,20,23,25,27,28 W-WNW 5:40 6:30 5:00 4:50 5:50 7:00 4:50 4:50 17,19,20,23,25,28 NW-NNW 6:00 6:50 5:20 5:10 5:55 7:05 4:55 4:55 6-9

ARCADIS Exelon Generation Byron Station Evacuation Time Estimates Table 6-3: Evacuation Time Estimates for Partial EPZ Scenarios (staged)

  • Summe Winter Midwe Dy im Weknd Eenn idweek Daytime Weknd Eenn

__________IMdw.

Dyim 1

Daytime Daytimie nIu Affected Scenario:

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

ERPAs Weather:

Normal Adverse Normal Normal I Normal Adverse Normal Normal 90% Evacuation of 2-mile Zone and 5 Miles Downwind (STAGED) 20,25 N-NNW 3:40 4:10 3:25 3:30 3:45 4:30 3:30 3:30 20 NNE-NE 3:40 4:10 3:25 3:30 3:45 4:30 3:25 3:30 No Extra ENE-ESE 3:00 3:30 2:50 2:40 2:45 3:30 2:25 2:25 17 SE-SW 3:25 3:55 3:15 3:25 3:35 4:20 3:25 3:30 25 WNW-NW 3:40 4:10 3:25 3:30 3:45 4:30 3:25 3:30 90% Evacuation of 2-mile Zone and 5 Miles Downwind (STAGED) 20,25 N-NNW 4:55 5:45 4:55 4:50 5:00 6:10 4:50 4:50 20 NNE-NE 4:55 5:45 4:55 4:50 5:00 6:10 4:50 4:50 No Extra ENE-ESE 4:30 5:20 3:50 3:40 4:45 5:55 3:45 3:45 17 SE-SW 5:40 6:30 5:10 5:05 5:45 6:55 4:50 5:00 25 WNW-NW 4:55 5:45 4:55 4:50 5:00 6:10 4:50 4:50 6-10

0 ARCADIS Exelon Generation Byron Station Evacuation Time Estimates Stage 2 Departure times - Byron EPZ 1

c.0.8

/

resident day

  • 0.6 resident night worker 4104-col

=

-special E 0.2 U

transit depend 0

0 50 100 150 200 time (minutes)

Figure 6-1.

Departure Curves for Stage 2 Zones, Byron Station EPZ 6-11

0 ARCADIS Exelon Generation Byron Station Evacuation Time Estimates Byron -- Population Growth vs ETE (Full EPZ) 5:00 4:50 4:40 Y = 0.1917x + 0. 1544 4:30

__R'

= 0.8532 w 4:20 4-lOmile 4:10 Mo 4:00

<b

/,,,-,Upper 3:50 Linear (10mile) 3:40 3:30 0%

5%

10%

15%

20%

Pop Increase %

Figure 6-2.

Byron Sensitivity of ETE to Population Growth (Summer Weekday, Normal Weather, Full EPZ) 6-12

C2 ARCADIS Exelon Generation Byron Station Evacuation Time Estimates VISUM 11.52 PTV AG IN_SumDay_10mle-RC.ver jertelft am: 06.08.2C Figure 6-3.

Byron Predicted Traffic Volume by Link with Full Network (Summer Weekday, Normal Weather, Full EPZ) 6-13

ARCADIS Exelon Generation Byron Station Evacuation Time Estimates VISUM 11.52 PTV AG INSumDay10rmile-RC.ver lerstellt am: 13.08.2012 Figure 6-4.

Byron Predicted Traffic Volume by Link with IL 72 Westbound Link Removed (Summer Weekday, Normal Weather, Full EPZ) 6-14

ARCADIS Exelon Generation Byron Station Evacuation Time Estimates Evacuation Vehicles by Hour Crossing EPZ Boundary Fair Weather, Winter Day, Full EPZ Scenario 8000 7000 o 6000 CL 5000 E 4000 W

1 2-mile E 2000 1.'*

M 530 L

-mile E 2000 1 10-mile z

1000 0

1 2

3 4

5 6

Simulation Hour 10-mile: 90% ETE = 3:40, 100% = 6:15 Figure 6-5.

Time Distribution of Vehicles on the Network (Full 10-mile EPZ, Winter Weekday, Normal Weather) 6-15

ARCADIS Exelon Generation Byron Station Evacuation Time Estimates 0

Mobilization and Cumulative EPZ Evacuation 20 F100%

18 90%

16 80%

14 70%

12 60%

10 50%

8 40%

6 30%

4 20%

2 10%

0 0%

  • Screenline
  • Mobilization 0

50 100 150 200 250 300 Time after Evacuation Order issued (min) 350 Figure 6-6.

Comparison of Vehicle Mobilization and Departure Rates (total vehicles 22,307) 6-16

ARCADIS Exelon Generation Byron Station Evacuation Time Estimates Table 6-4: Summary of Network Performance (Full 10-mile EPZ, Winter Weekday, Normal Weather)

Network Parameter All Vehicles Background and vcuto Shadow Traffic Avg Delay (s) 3883.3 612.5 5784.0 Avg Stop Delay (s) 984.8 223.0 1427.6 Avg # of Stops 510.5 51.9 777.1 Avg Speed (mph) 26.3 39.1 22.7 Avg Travel Time (min) 2.78 1.66 3.43 Vehicle Hours Traveled 82124.7 18006.8 64117.9

  1. of Completed Trips 29,543 10,858 18,685 6-17

0 ARCADIS Exelon Generation Byron Station Evacuation Time Estimates Table 6-5: ETE for Special Facilities, Byron Station EPZ (Full 10-mile EPZ, Winter Weekday, Normal Weather)

Vehicles Distance to Outbound Travel Time Population M

ilt Ling EPZ Travel to EPZ Facility Time TimeET(mn (residents)

Type (min)

(min)

Boundary Speed Boundary (mi)

(mph)

(min)

The Neighbors 85 3

Van 60 15 7.4 51.5 9

84 1

Ambulance 90 to 120 30 7.4 51.5 9

129 to 159 1

WC van 90 to 120 30 7.4 51.5 9

129 to 159 Pine Crest Manor 129 6

Van 60 15-30 4.2 47.5 5

80-95 2

Ambulance 90 to 120 30 4.2 47.5 5

125 to 155 4

WC van 90 to 120 30 4.2 47.5 5

125 to 155 Oregon Health Care Center 66 5

Van 60 30 6

47 8

98 4

Ambulance 90 to 120 30 6

47 8

128 to 158 2

WC van 90 to 120 30 6

47 8

128 to 158 Stouffer Terrace 16 1

Van 60 15 6

47 8

83 Bernice Hammer Terrace 8

1 Van 60 15 7.6 47 10 85 6-18

ARCADIS Exelon Generation Byron Station Evacuation Time Estimates Table 6-6: ETE for Schools and Daycares in Byron Station EPZ (Full 10-mile EPZ, Winter Weekday, Normal Weather)

Vehicles Distance Outbound Travel Time Mobilization Loading to EPZ Travel to EPZ ETE Facility Population Time Time t

P rvl t

P T

Type (min)

(min)

Boundary Speed Boundary (min)

(mi)

(mph)

(min)

Rahn Jr High 255 5

Bus 120 45 4.2 47.5 5

170 Byron Middle School 360 7

Bus 120 45 7.5 51.5 9

174 Byron High School 569 10 Bus 120 45 7.5 51.5 9

174 Mary Morgan Grade School and Byron 226 Pre-K 724 13 Bus 120 45 7.5 51.5 9

174 Ogle County Edu Coop 34 2

Bus 60 15 6.2 47.5 8

83 Oregon Sr High 532 10 Bus 120 45 6.5 47 8

173 Etnyre Middle School 439 8

Bus 120 45 6.8 47 9

174 Jefferson Grade School 338 6

Bus 120 45 7

47 9

174 Highland Elementary 413 8

Bus 120 45 8.8 48 11 176 Meridian Jr High 453 8

Bus 120 45 8.8 48 11 176 Stillman Valley Sr High 604 11 Bus 120 45 8.8 48 11 176 Chana Education Ctr 77 52 Auto 30 2

7.4 47 9

41 Kings Consolidated School 128 2

Bus 90 30 4.4 47.4 6

126 Jack & Jill Nursery School 16 1

Van 60 15 4.2 47.5 5

80 Bright Beginnings Pre School 21 1

Van 60 15 7.5 51.5 9

84 Best Beginnings Child Care 136 6

Van 60 15 6.5 47 9

84 St Mary's Head Start 21 1

Van 60 15 6.5 47 9

84 Valley Covenant Preschool 48 2

Van 60 15 8.8 48 11 86 6-19

ARCADIS Exelon Generation Byron Station Evacuation Time Estimates

7. Traffic Control and Evacuation Confirmation 7.1 General Evacuation simulation results have been reviewed to assess access control locations, traffic management locations and recommendations for the Byron Station EPZ. Traffic control plans for each county were reviewed to confirm that traffic management will be implemented at key intersections on all designated evacuation routes. Predicted queuing at high-volume intersections is summarized in Table 7-1. Only four of those intersections are located inside the EPZ. The average queue length exceeds 200 feet at one signalized intersection on State Highway 2 in Byron.

Similar queuing is predicted at a signalized intersection in Rockford on State Highway 251, more than 2 miles outside of the EPZ.

7.2 Evacuation Access Control Locations Access control measures were not specifically addressed in the conduct of this study.

Background traffic within the EPZ was not found to be a significant contributor to traffic congestion during the early stages of evacuation.

7.3 Traffic Management Locations and Tactics to Facilitate Evacuation The traffic simulation results for Byron indicate that traffic flow will encounter significant congestion in and around the city of Byron. The traffic flow maps provided in Appendix D and the data in Table 7-1 help to pinpoint locations where traffic management can be deployed to best effect. Congestion in Byron is predicted in the first hour and persists until hour 4. Congestion then develops along Kishwaukee Road and in several streets on the south side of Rockford, just outside the EPZ. The northeast corner of the network takes the longest to clear.

7-1

0 ARCADIS Table 7-1: Predicted Queuing at Major Intersections (Full 10-mile EPZ, Winter Weekday, Normal Weather)

Exelon Generation Byron Station Evacuation Time Estimates Average Intersection Namie County or City Control Type Queue Volume (feet)

Lincoln Hwy (IL 2) & N Galena Ave (IL 26)

Dixon Signalized 128.379 12,980 S West Ave (IL 26) & W South St Freeport Signalized 129.180 9,960 S West Ave (IL 26) & County Hwy 35 Freeport Signalized

<20 8,796 W Coffman Rd & County Hwy 30 Freeport Two-way Stop

<20 7,942 County Hwy 11 & E Montague Rd Baileyville Two-way Stop 51.3 7,682 E Chicago Ave (IL 72) & IL 251 Davis Junction*

Two-way Stop 56.0 5,750 S Lowell Park Rd & W Penn Corner Rd Unincorporated*

Two-way Stop

<20 5,558 IL 64 & County Hwy 35 Mt. Morris*

Two-way Stop

<20 5,544 E Blackhawk Dr (IL 2) & N Colfax St Byron*

Signalized 254.180 5,540 1 th St. (I L 251) & Samuelson Rd Rockford Signalized 242.392 5,236 Lincoln Hwy (IL 2) & N Galena Ave (IL 26)

Dixon Signalized 128.379 12,980 tion inside the EPZ 7-2

Exelon Generation V ARCADIS Byron Station Evacuation Time Estimates

8.

References Earth Tech, 2003: Evacuation Time Estimates for the Byron Station Plume Exposure Pathway Emergency Planning Zone, prepared by Earth Tech, Inc. for Exelon Nuclear, December 2003.

NRC, 1980: Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants, NUREG-0654, FEMA-REP-1, Rev. 1, U.S. Nuclear Regulatory Commission, Federal Emergency Management Agency, November 1980.

NRC, 1992: State of the Art in Evacuation Time Estimate Studies for Nuclear Power Plants, NUREG/CR-4831, T. E. Urbanik and J. D. Jamison, Pacific Northwest Laboratory, U.S. Nuclear Regulatory Commission, March 1992.

NRC, 2011: Criteria for Development of Evacuation Time Estimate Studies, NUREG/CR-7002, J. Jones and F. Walton, Sandia National Laboratories, and B. Wolshon, Louisiana State University, November 2011.

ORNL, 1990: Evaluating Protective Actions for Chemical Agent Emergencies, ORNL-6615, GO. Rogers, et al., Oak Ridge National Laboratory, prepared for U.S. Department of the Army and Federal Emergency Management Agency, April 1990.

8-1

ARCADIS Appendix A Transient and Special Facility Population Data

w cuff~e ad WO Skvl AddW ft t

0 G

L E*Leaf WNWr 0 G L

n Scott Legend st Gmv Rd Cn

  • -.Facility Type SOUN EMPLOYMENT

& 19 23]*

HOTEL

~

I RECREATION

...... MW fBase Data Legend wo.

flc 8,

Byron Plant Sk d P

o. Rd 10 Miles from Plant
  • Y Township Boundary Sub-Area Boundary M-10 EPZ Boundary R

0 2

4 A ARCADIS-

  • _BYRON GENERATING F

gSTA TION POPULATI ON I

Flagg We~~nX SU*ftAREA Appendix A-Page 1 of 9

SfSeWard U-U ApPeOndb A - Page 2 of 9

Table A-I. Major Employers in Byron EPZ Population Vehicle Winter Week-Week-day night Week-end Summer Week-Week-day night Week-end Winter Week-Week-day night Week-end Summer Week-Week-day night Week-end Facility ERPA Austin Westran Skandia Quality Metal Finishing Co Exelon Byron Station Byron Forest Preserve District Kable News Spectrum Meats Sampler Publishing E D Etnyre & Company HA International Stillman Banc Byron Bank Neighbors Rehabilitation Center Woods Equipment Ogle County' Education Coop 17 27 17 19 23 12 14 12 20 20 23 17 17 20 17 85 68 180 750 45 80 40 68 275 35 45 50 90 240 41 15 12 100 150 15 0

10 12 32 20 5

5 10 60 0

0 0

11 50 15 0

10 0

0 0

0 0

0 0

0 85 68 180 750 65 80 40 68 275 35 45 50 90 240 20 15 12 100 150 30 0

10 12 32 20 5

5 10 60 0

0 0

II 50 10 0

t0 0

0 0

0 0

0 0

0 85 68 180 600 45 80 40 68 275 35 45 50 90 240 41 15 12 100 150 15 0

10 12 32 20 5

5 10 60 0

0 0

11 50 15 0

10 0

0 0

0 0

0 0

0 85 68 180 600 65 80 40 68 275 35 45 50 90 240 20 15 12 100 150 30 0

10 12 32 20 5

5 10 60 0

0 0

I1 50 10 0

10 0

0 0

0 0

0 0

0 Appendix A - Page 3 of 9

Table A-2. Recreation Facilities in Byron EPZ I

r

  • I.

Popu Winter Week-Week-Week-lation I Week-Vehicle Summer Winter Summer Week-Week-I Week-Week-Week-I Week-Week-Week-Occu-Adjust-pancy ment Factor Factor Facility ERPA day night end I day night end I day night end day night end 4

4 4

I 4

+

Lake Louise Byron's Sportsman Club Byron Dragway Byron Forest Preserve Dist.

Prairie View Golf Course Moto Sports Park Rochelle Conservation Club Camp Ross Sunset Golf Course The Cabins of White Pines White Pines Forest S. P. (camp)

White Pines Forest S. P. (visit)

Camp Emmaus Hansen's Hideaway Lake LaDonna (camp)

Lake LaDonna (visit)

White Pines Ranch Lowden Memorial S. P. (camp)

Lowden Memorial S. P. (visit)

Pride of Oregon River Road Camping & Marina Silver Ridge Golf Course Stronghold Camp Blackhawk Center Camp Lowden Boy Scout Camp Castle Rock State Park Lowden-Miller State Park Lutheran Outdoor Ministries Ctr Nash Recreation Center Oregon Golf Club 17 19 23 23 23 23 25 12 12 14 14 14 20 14 14 14 14 19 19 19 19 19 19 20 20 20 20 20 20 20 0

0 0

0 75 0

40 36 0

0 0

0 24 0

0 0

250 0

0 0

0 0

0 100 80 0

0 0

130 0

0 80 0

0 0

0 0

36 0

0 0

0 24 0

0 0

250 0

0 0

0 0

0 250 80 0

0 0

0 0

0 80 300 140 105 0

40 36 0

0 100 70 70 0

0 0

250 0

50 0

0 100 200 100 100 0

0 50 0

0 810 0

300 240 150 600 120 120 90 30 500 120 120 300 720 300 250 250 80 60 280 150 276 100 160 75 40 200 103 80 810 80 300 50 0

300 75 120 0

30 500 0

120 300 720 0

250 250 0

0 280 0

276 100 160 20 0

200 0

0 1050 80 500 300 150 1800 150 120 120 30 680 200 140 385 735 400 250 308 100 120 350 200 476 100 200 145 75 200 0

100 0

0 0

0 40 0

16 6

0 0

0 0

10 0

0 0

100 0

0 0

0 0

0 40 16 0

0 0

65 0

0 40 0

0 0

0 0

6 0

0 0

0 10 0

0 0

100 0

0 0

0 0

0 100 16 0

0 0

0 0

0 40 120 70 56 0

16 6

0 0

33 35 28 0

0 0

100 0

20 0

0 53 67 40 20 0

0 25 0

0 216 0

120 120 80 240 48 12 60 10 167 60 48 120 240 120 100 83 32 30 112 80 92 40 32 30 16 100 52 53 216 40 120 25 0

120 30 12 0

10 167 0

48 120 240 0

100 83 0

0 112 0

92 40 32 8

0 100 0

0 280 40 200 150 80 720 60 12 80 10 227 100 56 154 245 160 100 103 40 60 140 107 159 40 40 58 30 100 0

67 3

0.80 2

2 0.80 2

1.5 0.80 2

0.80 2.5 12 4 bus 1.5 3

3 2

2.5 2.5 3

2.5 2.5 3

2.5 2

2.5 1.5 0.80 3

2 0.80 5

1.00 2.5 2.5 2

2 1.5 page 1 of 2 Appendix A - Page 4 of 9

Table A-2. Recreation Facilities in Byron EPZ Population Vehicle Winter Week-Week-Week-day night end Summer Week-Week-Week-day night end Winter Week-Week-Week-day night end Summer Week-Week-Week-day night end Occu-Adjust-pancy ment Factor Factor Facility ERPA Rock River Center 20 60 0

0 50 0

0 6

0 0

4 0

0 Bishop Lane Retreat House 17 160 160 240 240 240 440 80 80 120 120 120 220 2

Fuller Memorial Forest Preserve 17 24 0

40 120 0

160 12 0

20 60 0

80 2

Kilbuck Forest Preserve 17 0

0 18 72 0

72 0

0 9

36 0

36 2

Severson Dells Forest Preserve 17 0

0 25 75 0

100 0

0 13 38 0

50 2

Camp McCormick Girl Scouts 23 120 120 120 300 300 300 24 24 24 60 60 60 5

Weld Memorial Park 23 0

0 0

210 0

270 0

0 0

84 0

108 2.5 Kings Camp 28 0

0 0

300 300 385 0

0 0

120 120 154 2.5 page 2 of 2 Appendix A - Page 5 of 9

Table A-3. Hotels and Motels in Byron EPZ Population Vehicle Winter Week-Week-Week-day night end Summer Week-Week-Week-day night end Winter Week-Week-Week-day night end Summer Week-Week-Week-day night end Facility zone Rooms Mt Morris Motel 12 10 12 12 12 12 12 12 12 12 12 12 12 12 White Pines Inn 14 25 30 25 25 30 25 25 30 25 25 30 25 25 Blackhawk's Trail Motel 17 6

8 6

6 8

6 6

8 6

6 8

6 6

Paddlewheel Inn 19 166 48 44 44 210 204 204 48 44 44 174 170 170 Chateau Lodge 19 12 14 14 14 14 14 14 12 12 12 12 12 12 Patchwork Inn 20 9

11 10 10 12 10 10 11 10 10 12 10 10 Appendix A - Page 6 of 9

Table A-4. School Facilities in Byron EPZ School City zone Students Staff Bus Auto Rahn Jr High Mt Morris 12 255 45 5

31 Byron Middle School Byron 17 360 64 7

44 Byron High School Byron 17 569 100 10 69 Mary Morgan GS and Byron 226 Pre-K Byron 17 724 128 13 88 Ogle County Edu Coop Byron 17 34 7

2 0

Oregon Sr High Oregon 20 532 94 10 65 Emyre Middle School Oregon 20 439 77 8

54 Jefferson Grade School Oregon 20 338 60 6

41 Highland Elementary Stillman Valley 23 413 73 8

50 Meridian Jr High Stillman Valley 23 453 80 8

55 Stillman Valley Sr High Stillman Valley 23 604 107 11 74 Chana Education Ctr Chana 25 77 14 52 Kings Consolidated School Kings 28 128 23 2

16 Appendix A - Page 7 of 9

Table A-5. Large Daycare Facilities in Byron EPZ Capacity Facility City zone Children staff van auto Jack & Jill Nursery School Mt Morris 12 13 3

1 0

Bright Beginnings Pre School Byron 17 17 4

1 1

Teddy Bear Day Care Ctr Oregon 20 8

2 0

2 Best Beginnings Child Care Oregon 20 116 20 6

2 St Mary's Head Start Oregon 20 17 4

1 1

Valley Covenant Preschool Stillman Valley 23 40 8

2 2

Appendix A - Page 8 of 9

Table A-6. Elder Care Facilities in Byron EPZ weekday night & weekend resident ambu-wheel-ambu-wheel-Facility City zone capacity staff lance van chair van auto staff lance van chair van auto (a) hospital or nursing home The Neighbors Byron 17 101 40 1

3 1

32 20 1

3 1

12 Pine Crest Manor Mt Morris 12 143 120 2

6 4

104 24 2

6 4

8 Oregon Health Care Center Oregon 20 104 36 4

5 2

18 16 4

5 2

0 (b) assisted living Stouffer Terrace Oregon 20 16 6

1 4

2 1

Bernice Hammer Terrace Oregon 20 8

2 1

0 1

1 Appendix A - Page 9 of 9

ARCADIS Appendix B Telephone Survey of EPZ Residents

Byron EPZ Summary of Telephone Survey Results Completed surveys Data Uncertainty + or - 5%

at 95% confidence level total population total HH persons per HH Results (after adjustment) vehicles used when all at home fraction taking 1 vehicle fraction taking 2 veh fraction taking 3 or more 377 29241 11428 2.56 1.41 0.65 0.31 0.05 Demographic Adjustment census 2010 SURVEY age for head adjustment Age Mix

Response

of household factor (percent)

(percent) under55 22.8 55.4 2.43 55-64 24.4 19.3 0.79 65 and over 52.8 25.3 0.48 Work Outside Home

(% of HH) one or more work outside 71.2 Of those who work outside percent take vehicle to work 93.8 evacuate direct from work 31.3 stay outside EPZ 21.2 return home to evacuate 47.5 one returns 29.1 2 or more return 18.4 Shifts Weekday Swing shift Graveyard evening/weekend rotate (percent) 81.6 4.2 3.1 6.1 5.1 time distribution (fraction) 0 to 15 15 to 30 30 to 45 45 to 60

> 60 minutes minutes minutes minutes minutes leave work after notice 0.77 0.15 0.05 0.02 0.01 travel home 0.47 0.33 0.14 0.02 0.05 depart after work return 0.41 0.35 0.12 0.09 0.03 0 to 20 20 to 40 40 to 60 60 to 90

> 90 depart (all at home) 0.27 0.45 0.18 0.05 0.05 Appendix B page 1 of 7

13662 LH/CH ARCADIS Exelon Survey Final v6 - August 23, 2011 INTRODUCTION Hello, my name is and I am calling from MDC Research, a public opinion firm. We are conducting a brief survey to gather information from households in your area about emergency response planning, and we'd like to include your opinions. This survey is being conducted on behalf of the (insert facility name) Nuclear Facility, and will take approximately 5 minutes to complete. We are not trying to sell you anything. The information gathered fiom this survey will help local agencies more effectively provide community assistance should an emergency situation arise.

Can I please speak with an adult member of the household?

SCREENER S1.

What is the zip code of your primary residence? This is the home where you live the majority of the time. DO NOT READ ZIP CODE LIST List of appropriate zip codes will be displayed here 99999 Location outside the EPZ - THANK & TERMINATE S2.

Which of the following categories best describes your age?

11 Under 18 yrs of age - ASK FOR REFERRAL or THANK & TERMINATE 12 18 to 24 13 25 to 34 14 35 to 44 15 45 to 54 16 55 to 64 17 65 to 74 18 75 or older 98 (DO NOT READ) Refused QUESTIONNAIRE Q1 How many people currently reside in your household?

Record:

  1. of residents 998 (DO NOT READ) Refused - THANK & TERMINATE Q2 How many motor vehicles are normally based at your home?

Arcadis Exelon 1

©201 1. Market Decisions Corporation Appendix B page 2 of 7

13662 LH/CH Record:

  1. of vehicles 997 None - SKIP TO Q14 998 (DO NOT READ) Refused Q3 How many members of your household are over the age of 16?

Record:

  1. of residents 998 (DO NOT READ) Refused Q4 How many members of your household are licensed drivers?

Record:

  1. of drivers 998 (DO NOT READ) Refused Q5 How many of the adults in your household work outside the home?

Record

--) Skip to Q6A 997 None - Continue to Q5A 998 (DO NOT READ) Refused If refused, explain; The nature of this project is to estimate traffic volumes and flow in the event of an emergency evacuation, so this data is necessary in order for us to continue with the survey.

If still refused - THANK & TERMINATE Q5A (ONLY ASK IF Q5=997) Which of the following best describes the non-working adults in your household? MULTIPLE MENTION - IP NOTE: No more mentions than Q3 mentions.

11 Currently unemployed/actively looking for work 12 Retired 13 On Disability or leave of absence 14 Student/continuing education 15 Homemaker 99 Other - please specify SKIP TO Q1I Repeat the following Q6A-F sequence for each working adult cited in Q5 For each of the working adults you just referenced, I'd like to ask a few questions related to what their likely actions would be in the case of an emergency evacuation. I understand that I will be asking you to speculate on what other members of the household may do in this situation, but your best guesses are just fine for our purposes.

Q6A Who is the first working adult in the household that you are thinking about? What is their relationship to you?

Arcadis Exelon 2

©2011. Market Decisions Corporation Appendix B page 3 of 7

13662 LH/CH 1

Self 2

Spouse or significant other 3

Parent of child 4

Other relative or in-law 5

Roommate 6

Boarder 7

Other Q6B Which of the following best describes this person's usual work schedule?

1 Monday - Friday, 8:00am to 5:00pm 2

Swing Shift 3

Graveyard 4

Evenings and weekends 5

Rotating shifts 6

Other or irregular schedule 7

(DO NOT READ) Don't know Q6C Does this person generally use a personal vehicle to commute back and forth to work?

I Yes 2

No 7

(DO NOT READ) Don't know Q6D If an evacuation notice were given while this person was at work, do you think they would most likely...

1 Evacuate directly from work 2

Come home first and then evacuate, or 3

Stay outside the evacuation zone where they work -4 Skip to Q7 7

(DO NOT READ) Don't know Q6E How long do you think it would take this person to get prepared and actually leave work?

(Read list if necessary) 1 Less than 15 minutes 2

15 to 30 minutes 3

30 to 45 minutes 4

45 to 60 minutes 5

More than 60 minutes 7

(DO NOT READ) Don't know Arcadis Exelon 3

©201 1. Market Decisions Corporation Appendix B page 4 of 7

13662 LH/CH If response at 6D is 1, skip from here to Q7 Q6F About how long does it take this household member to get from work to home?

(Read list if necessary) 1 Less than 15 minutes 2

15 to 30 minutes 3

30 to 45 minutes 4

45 to 60 minutes 5

More than 60 minutes 7

(DO NOT READ) Don't know Q7A-F Repeat Q6 sequence for worker #2 Q8A-F Repeat Q6 sequence for worker #3 Q9A-F Repeat Q6 sequence for worker #4 Q10 And once everyone who is coming home from work has arrived, how long would it take to prepare and depart from home, taking into consideration whether or not someone else is usually home who may be starting these preparation while they are travelling?

1 Less than 15 minutes 2

15 to 30 minutes 3

30 to 45 minutes 4

45 to 60 minutes 5

More than 60 minutes 7

(DO NOT READ) Don't know Q11 Are any of the licensed drivers in your household restricted to daytime driving only?

1 Yes 2

No 9

(DO NOT READ) Refused Q12 If an evacuation were ordered when all household members were at home (for example, at night or on a weekend), approximately how long would it take your household to Arcadis Exelon 4

©2011. Market Decisions Corporation Appendix B page 5 of 7

13662 LH/CH prepare to depart? Please assume that you are advised to plan to be away from your home for 3 days. Would you say that it would take... READ LIST 1

2 3

4 5

Less than 20 minutes to depart 20 to 40 minutes to depart 40 to 60 minutes to depart 60 to 90 minutes to depart; or More than 90 minutes to depart Q13 How many vehicles would your household take if an evacuation were ordered when all household members were at home?

Record:

  1. of vehicles 998 (DO NOT READ) Refused Q14 Are any members of your household seasonal residents? And by seasonal we mean any people who do not reside in your home the majority of the year.

1 2

9 Yes No - SKIP TO Q15 (DO NOT READ) Refused Q14A (ASK IF Q14=1) How many of your <insert Q1 response> household members are seasonal?

Record:

  1. of seasonal household members 998 (DO NOT READ) Refused Q14B (ASK IF Q14=1) What seasons do they live in another location away from your home?

READ LIST - Multiple Mention 1

2 3

4 Spring Summer Fall Winter Q15 Would any member of your household require a specialized vehicle, such as a wheelchair, van or ambulance, to evacuate from your home in case of an emergency?

1 Yes 2

No Arcadis Exelon 5

©2011. Market Decisions Corporation Appendix B page 6 of 7

13662 LH/CH 9

(DO NOT READ) Refused This is all the questions we have for you today/tonight. Thank you for participating in this survey. Your responses will help us to make an accurate prediction of traffic conditions during an emergency situation. If you have any questions about this survey, please feel free to contact

<insert contact name, job title, and phone number/email>.

Arcadis Exelon 6

©2011. Market Decisions Corporation Appendix B page 7 of 7

ARCADIS Appendix C Roadway Network Map and Data Table

arI Roadway Network for Byron Station ETE Analysis August 2012 Legend O

Byron Station Nodes Road Classification

-- Freeway Principal Arterial Major Arterial Minor Arterial Collector Local Rd Byron EPZ V ARCADIS Infrastr ture Wate noronrnent.uidngs 1

2 4

ExelorL Appendix C - Page 1 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Lik -Nde DNoe Length Lane Number of Roadway Type Ratraeio Fvelowhr(ph Link#

UNod D-ode (ml)

Width (ft)

Lanes Satattio FlowFF5 mph 1

98 97 0.016 12 2

Freeway 4100 65 2

125 126 0.462 12 2

Ramp 3000 55 3

127 128 0.051 12 1

Major Arterial 1300 55 4

128 127 0.051 12 1

Major Arterial 1300 55 5

137 138 0.092 12 1

Major Arterial 1300 40 6

140 115 0.95 12 1

Ramp 1500 35 7

140 139 0.047 12 1

Major Arterial 1300 40 8

141 140 0.813 12 1

Major Arterial 1300 40 9

138 113 1.226 12 1

Ramp 1500 35 10 138 141 0.011 12 1

Major Arterial 1300 40 11 142 143 0.147 12 1

Major Arterial 1300 40 12 143 142 0.147 12 1

Major Arterial 1300 40 13 147 148 0.035 1

12 1

Major Arterial 1300 55 14 149 116 0.948 12 1

Ramp 1500 35 15 150 151 0.999 12 1

Principal Arterial 1600 55 16 154 147 0.104 12 2

Principal Arterial 3700 55 17 153 154 0.015 12 1

Principal Arterial 1600 45 18 154 153 0.015 12 1

Principal Arterial 1600 45 19 155 154 0.084 12 2

Principal Arterial 3700 55 20 156 155 0.073 12 1

Major Arterial 1300 55 21 150 117 1.057 12 1

Ramp 1500 35 22 119 151 1.182 12 1

Ramp 1500 35 23 159 121 1.222 12 1

Ramp 1500 35 24 160 161 0.845 12 2

Principal Arterial 3320 45 25 120 123 1.737 12 2

Freeway 4100 65 26 160 123 0.831 12 1

Ramp 1500 35 27 122 161 1.274 12 1

Ramp 1500 35 28 109 163 0.324 12 2

Freeway 4100 65 29 99 107 0.683 12 1

Ramp 1500 55 30 106 100 0.375 12 1

Ramp 1500 55 31 108 163 0.311 12 1

Ramp 1500 55 32 102 164 0.303 12 2

Freeway 4100 65 33 108 165 0.258 12 2

Freeway 4100 65 34 109 165 0.534 12 1

Ramp 1500 55 35 163 105 0.142 12 2

Freeway 4100 65 36 102 104 0.319 12 1

Ramp 1500 55 37 105 101 0.387 12 1

Ramp 1500 55 38 167 166 0.103 12 2

Principal Arterial 3320 45 39 168 166 0.007 12 1

Collector / Local Road 1300 40 40 ill 168 0.372 12 1

Ramp 1500 35 41 169 98 0.695 12 1

Ramp 1500 55 42 103 164 0.521 12 1

Ramp 1500 55 43 170 110 0.329 12 1

Ramp 1500 35 44 170 168 0.212 12 2

Principal Arterial 3320 45 45 171 170 0.024 12 1

Collector / Local Road 1300 40 46 166 171 0.695 12 2

Principal Arterial 3320 45 47 172 110 0.77 12 2

Freeway 4100 65 48 166 173 0.493 12 1

Ramp 1500 35 49 182 183 0.014 12 1

Major Arterial 1300 45 50 183 182 0.014 12 1

Major Arterial 1300 45 51 187 177 0.011 12 1

Collector/ Local Road 1300 45 52 189 190 0.214 12 1

Principal Arterial 1600 45 53 190 189 0.214 12 1

Principal Arterial 1600 45 54 190 191 0.175 12 1

Major Arterial 1300 55 55 191 190 0.175 12 1

Major Arterial 1300 55 Page 1 of 38 Page 1of 38Appendix C - Page 2 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Link #

U-Node D-Node Length Lane Number of Roadway Type Saturation Flow FFS (mph)

(mi)

Width (ft)

Lanes Rate (vehlhr) 56 189 191 0.067 12 1

Minor Arterial 1300 45 57 191 189 0.067 12 1

Minor Arterial 1300 45 58 96 193 0.291 12 2

Ramp 3000 55 59 176 195 0.021 12 1

Ramp 1500 35 60 139 143 0.769 12 1

Major Arterial 1300 40 61 196 197 0.247 12 1

Major Arterial 1300 40 62 196 140 0.014 12 1

Collector/ Local Road 1300 40 63 139 198 0.013 12 1

Collector!I Local Road 1300 40 64 1199 138 0.006 12 1

Collector!/ Local Road 1300 40 65 141 197 0.006 12 1

Collector / Local Road 1300 40 66 152 150 0.118 12 1

Principal Arterial 1600 55 67 201 152 0.118 12 1

Principal Arterial 1600 55 68 149 201 0.303 12 1

Principal Arterial 1600 55 69 202 149 0.107 12 1

Principal Arterial 1600 55 70 151 149 0.017 12 1

Collector /Local Road 1300 45 71 201 150 0.004 12 1

Collector /Local Road 1300 45 72 151 202 0.351 12 1

Principal Arterial 1600 55 73 118 201 0.37 12 1

Ramp 1500 35 74 159 162 0.843 12 2

Principal Arterial 3320 45 75 162 160 0.028 12 1

Collector! Local Road 1300 45 76 161 159 0.029 12 1

Collector/ Local Road 1300 45 77 203 204 1

12 1

Major Arterial 1300 55 78 204 203 1

12 1

Major Arterial 1300 55 79 205 206 0.114 12 1

Major Arterial 1700 40 80 206 205 0.114 12 1

Major Arterial 1700 40 81 212 213 0.496 12 1

Major Arterial 1300 55 82 213 212 0.496 12 1

Major Arterial 1300 55 83 217 218 0.17 12 1

Principal Arterial 1600 55 84 218 217 0.17 12 1

Principal Arterial 1600 55 85 181 220 0.046 12 1

Major Arterial 1300 55 86 220 181 0.046 12 1

Major Arterial 1300 55 87 132 224 3.286 12 1

Major Arterial 1300 55 88 224 132 3.286 12 1

Major Arterial 1300 55 89 237 238 0.319 12 1

Major Arterial 1300 55 90 238 237 0.319 12 1

Major Arterial 1300 55 91 240 241 1.435 12 1

Principal Arterial 1600 55 92 241 240 1.435 12 1

Principal Arterial 1600 55 93 246 247 0.034 12 1

Major Arterial 1300 30 94 247 246 0.034 12 1

Major Arterial 1300 30 95 251 252 0.427 12 1

Principal Arterial

___1700 45 96 252 251 0.427 12 1

Principal Arterial 1700 45 97 252 253 0.078 12 1

Principal Arterial

___1700 45 98 253 252 0.078 12 1

Principal Arterial 1700 45 99 255 256 0.368 12 1

Principal Arterial 1600 55 100 256 255 0.368 12 1

Principal Arterial 1600 55 101 146 259 0.491 12 1

Principal Arterial 1600 55 102 259 146 0.491 12 1

Principal Arterial 1600 55 103 180 260 0.452 12 1

Major Arterial 1700 30 104 260 180 0.452 12 1

Major Arterial 1700 30 105 269 270 0.098 12 1

Principal Arterial 1600 55 106 270 269 0.098 12 1

Principal Arterial 1600 55 107 262 271 0.067 12 1

Principal Arterial 1700 45 108 271 262 0.067 12 1

Principal Arterial 1700 45 109 272 273 0.014 12 1

Principal Arterial 1700 45 110 273 272 0.014 12 1

Principal Arterial 1700 45 ill 274 275 0.091 12 1

Principal Arterial 1600 40 Page 2 of 38 Page 2of 38Appendix C - Page 3 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Lik#

UNd

-oe Length Lane Number of Roda ye Saturation Flow F(mh Link#

UNod D-ode (ml)

Width (ft)

Lanes Roda ye Rate (veh/hr) 112 275 274 0.091 12 1

Principal Arterial 1600 40 113 277 278 0.999 12 1

Major Arterial 1300 55 114 278 277 0.999 12 1

Major Arterial 1300 55 115 282 283 0.091 12 1

Principal Arterial 1600 45 116 283 282 0.091 12 1

Principal Arterial 1600 45 117 291 292 0.099 12 1

Major Arterial 1300 45 118 292 291 0.099 12 1

Major Arterial 1300 45 119 293 294 0.096 12 1

Major Arterial 1700 45 120 294 293 0.096 12 1

Major Arterial 1700 45 121 301 302 0.502 12 1

Major Arterial 1300 40 122 302 301 0.502 12 1

Major Arterial 1300 40 123 319 320 0.075 12 1

Major Arterial 1300 45 124 320 319 0.075 12 1

Major Arterial 1300 45_

125 326 327 0U66 12 1

Principal Arterial 1700 40 126 327 326 0.066 12 1

Principal Arterial 1700 40 127 337 338 0.354 12 1

Major Arterial 1300 55 128 338 337 0.354 12 1

Major Arterial 1300 55 129 343 344 1.393 12 1

Major Arterial 1300 55 130 344 343 1.393 12 1

Major Arterial 1300 55 131 347 348 0.507 12 1

Major Arterial 1300 55 132 348 347 0.507 12 1

Major Arterial 1300 55 133 343 349 0.134 12 1

Minor Arterial 1300 35 134 349 343 0.134 12 1

Minor Arterial 1300 35 135 350 351 2.819 12 1

Major Arterial 1300 55 136 351 350 2.819 12 1

Major Arterial 1300 55 137 351 352 0.417 12 1

Major Arterial 1300 55 138 352 351 0.417 12 1

Major Arterial 1300 55 139 361 362 0.82 12 1

Major Arterial 1300 55 140 362 361 0.82 12 1

Major Arterial 1300 55 141 364 365 2.762 12 1

Major Arterial 1300 55 142 365 364 2.762 12 1

Major Arterial 1300 55 143 145 146 0.511 12 1

Principal Arterial 1600 55 144 146 145 0.511 12 1

Principal Arterial 1600 55 145 202 380 0.779 12 1

Principal Arterial 1600 55 146 380 202 0.779 12 1

Principal Arterial 1600 55 147 382 383 3.439 12 1

Major Arterial 1300 55 148 383 382 3.439 12 1

Major Arterial 1300 55 149 316 317 0.938 12 1

Principal Arterial 1600 55 150 317 316 0.938 12 1

Principal Arterial 1600 55 151 307 321 0.062 12 1

Major Arterial 1300 45 152 321 307 0.062 12 1

Major Arterial 1300 45 153 299 387 0.251 12 1

Major Arterial 1300 45 154 387 299 0.251 12 1

Major Arterial 1300 45 155 219 220 0.082 12 1

Collector I Local Road 1300 40 156 220 219 0.082 12 1

Collector/ Local Road 1300 40 157 343 345 0.176 12 1

Collector I Local Road 1300 40 158 345 343 0.176 12 1

Collector!/ Local Road 1300 40 159 228 393 0.063 12 1

Principal Arterial 1600 55 160 393 228 0.063 12 1

Principal Arterial 1600 55 161 346 395 0.099 12 1

Collector! Local Road 1300 40 162 395 346 0.099 12 1

Collector! Local Road 1300 40 163 397 398 0.482 12 1

Collector / Local Road 800 55 164 398 397 0.482 12 1

Collector/ Local Road 800 55 165 249 250 0.103 12 1

Collector / Local Road 1300 40 166 250 249 0.103 12 1

Collector!/ Local Road J 1300 40 167 244 245 0.14 12 1

Collector!/ Local Road 1300 40 Page 3 of 38 Page 3of 38Appendix C - Page 4 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Lik#

UNd

-oe Length Lane Number of Roda ye Saturation Flow F(mh Link#

UNod D-ode (mi)

Width (ft)

Lanes Roda ye Rate (vehlhr)FF(mh 168 245 244 0.14 12 1

Collector/ Local Road 1300 40 169 404 405 1

12 1

Collector/ Local Road 800 45 170 405 404 1

12 1

Collector / Local Road 800 45 171 242 243 0.104 12 1

Collector /Local Road 1300 40 172 243 242 0.104 12 1

Collector / Local Road 1300 40 173 313 401 1.962 12 1

Major Arterial 1300 55 174 401 313 1.962 12 1

Major Arterial 1300 55 175 418 420 0.014 12 1

Major Arterial 1300 45 176 420 418 0.014 12 1

Major Arterial 1300 45 177 421 422 0.405 12 1

Ramp 1500 35 178 421 423 0.033 12 1

Principal Arterial 1600 45 179 423 421 0.033 12 1

Principal Arterial 1600 45 180 419 425 0.075 12 1

Collector/ Local Road 1700 40 181 425 419 0.075 12 1

Collector / Local Road 1700 40 182 427 428 0.147 12 1

Ramp 1500 35 183 429 433 0.235 12 1

Ramp 1500 35 184 429 435 0.024 12 1

Principal Arterial 1700 45 185 435 429 0.024 12 1

Principal Arterial 1700 45 186 437 438 0.405 12 1

Ram p 1500 35 187 439 437 0.326 12 1

Ramp 1500 35 188 441 440 0.015 12 1

Principal Arterial 1700 45 189 443 441 0.033 12 1

Principal Arterial 1700 45 190 445 435 0.211 12 1

Ramp 1500 35 191 440 446 0.99 12 1

Principal Arterial 1700 45 192 433 446 0.24 12 1

Ramp 1500 35 193 448 443 0.209 12 1

Ramp 1500 35 194 437 450 0.145 12 1

Ramp 1500 35 195 450 437 0.145 12 1

Ramp 1500 35 196 452 447 0.078 12 1

Minor Arterial 1700 35 197 452 449 0.074 12 1

Principal Arterial 1700 45 198 453 452 0.043 12 1

Principal Arterial 1700 45 199 454 450 0.058 12 1

Ramp 1500 35 200 454 455 0.044 12 1

Principal Arterial 1700 45 201 455 454 0.044 12 1

Principal Arterial 1700 45 202 450 455 0.042 12 1

Ramp 1500 35 203 455 450 0.042 12 1

Ramp 1500 35 204 455 456 0.085 12 1

Principal Arterial 1700 45 205 456 455 0.085 12 1

Principal Arterial 1700 45 206 450 456 0.104 12 1

Ramp 1500 35 207 457 453 0.057 12 1

Principal Arterial 1700 45 208 458 439 0.066 12 2

Freeway 4100 65 209 459 460 0.088 12 1

Minor Arterial 1700 40 210 462 464 0.12 10 1

Collector /Local Road 800 30 211 464 462 0.12 10 1

Collector/ Local Road 800 30 212 464 466 0.066 12 2

Principal Arterial 2800 30 213 466 464 0.066 12 2

Principal Arterial 2800 30 214 469 467 0.075 12 1

Principal Arterial 1700 45 215 470 466 0.072 12 2

Principal Arterial 2800 30 216 471 469 0.076 12 1

Principal Arterial 1700 45 217 473 477 0.074 12 1

Minor Arterial 1700 35 218 477 473 0.074 12 1

Minor Arterial 1700 35 219 476 480 0.077 11 2

Collector/ Local Road 1600 30 220 480 476 0.077 11 2

Collector/ Local Road 1600 30 221 483 480 0.033 12 2

Principal Arterial 2800 30 222 484 485 0.291 12 1

Ramp 1500 35 223 487 483 0.038 12 1

Collector/ Local Road 1700 45 Page 4 of 38 Page 4of 38Appendix C - Page 5 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Lik#

UNd

-oe Length Lane Number of Roda ye Saturation Flow F(mh Link#

UNod D-ode (mi)

Width (ft)

Lanes Roda ye Rate (vehlhr)

FS(mh 224 482 487 0.075 12 1

Principal Arterial 1700 45 225 488 489 0.062 12 1

Principal Arterial 1700 45 226 490 483 0.045 12 2

Principal Arterial 2800 30 227 487 490 0.027 12 1

Principal Arterial 1700 45 228 491 484 0.303 12 1

Ramp 1500 35 229 493 494 0.272 12 1

Ramp 1500 35 230 495 493 0.328 12 1

Ramp 1500 35 231 504 505 0.992 12 1

Major Arterial 1300 55 232 505 504 0.992 12 1

Major Arterial 1300 55 233 504 507 0.56 12 1

Major Arterial 1300 55 234 507 504 0.56 12 1

Major Arterial 1300 55 235 514 515 0.132 12 1

Collector /Local Road 1700 40 236 515 514 0.132 12 1

Collector /Local Road 1700 40 237 517 522 0.109 12 1

Collector/ Local Road 1700 40 238 522 517 0.109 12 1

Collector /Local Road 1700 40 239 522 526 0.059 12 1

Collector /Local Road 1700 40 240 526 522 0.059 12 1

Collector/ Local Road 1700 40 241 530 531 0.018 12 1-Collector/ Local Road 1700 40 242 531 530 0.018 12 1

Collector /Local Road 1700 40 243 531 534 0.081 12 1

Collector/ Local Road 1300 40 244 534 531 0.081 12 1

Collector / Local Road 1300 40 245 536 537 0.409 12 1 _

Ramp10 55 246 533 538 0.247 12 1

Ramp10 55 247 542 543 0.835 12 1

Ramp 1500 35 248 544 546 0.298 12 1

Ramp 1500 35 249 549 548 0.08 12 2

Freeway 4100 65 250 552 542 1.118 12 1

Ramp 1500 35 251 546 553 0.311 12 1

Ramp 1500 35 252 548 554 0.473 12 1

Ramp 1500 35 253 555 556 0.2 12 2

Freeway 4100 65 254 551 557 0.191 12 1

Minor Arterial 1700 40 255 557 551 0.191 12 1

Minor Arterial 1700 40 256 558 559 0.286 12 1

Ramp 1500 35 257 558 554 0.213 12 1

Minor Arterial 1700 40 258 555 560 0.247 12 1

Ramp 1500 35 259 561 562 0.114 12 1 _

Principal Arterial 1700 45 260 545 567 0.433 12 1

Minor Arterial 1300 35 261 567 545 0.433 12 1

Minor Arterial 1300 35 262 571 570 0.252 12 2

Freeway 4100 65 263 576 577 0.76 12 1

Major Arterial 1300 55 264 577 576 0.76 12 1

Major Arterial 1300 55 265 585 589 0.137 12 2

Principal Arterial 3320 45 266 590 585 0.139 12 2

Principal Arterial 3320 45 267 593 594 0.023 12 2

Principal Arterial 3320 45 268 594 593 0.023 12 2

Principal Arterial 3320 45 269 595 592 0.894 12 1

Ramp 1500 35 270 592 596 0.699 12 1

Ramp 1500 35 271 599 590 0.199 12 2

Principal Arterial 3320 45 272 594 600 0.676 12 2

Principal Arterial 3320 45 273 600 594 0.676 12 2

Principal Arterial 3320 45 274 601 590 0.385 12 1

Ramp 1500 35 275 601 602 0.237 12 2

Freeway 4100 65 276 599 602 0.256 12 1

Ramp 1500 35 277 603 604 0.283 12 1

Ramp 1500 35 278 603 605 0.24 12 2

Freeway 4100 65 279 589 605 0.385 12 1

Ramp 1500 35 Page 5 of 38 Pagesof 38Appendix C - Page 6 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Lik#

UNd

-oe Length Lane Number of Roda ye Saturation Flow F(mh Link#

UNod D-ode (ml)

Width (ft)

Lanes Roda ye Rate (vehlhr) 280 607 606 0.787 12 2

Freeway 4100 65 281 608 594 0.413 12 1

Ramp 1500 35 282 600 609 0.671 12 1

Ramp 1500 35 283 610 600 0,911 12 1

Ramp 1500 35 284 610 611 0.211 12 2

Freeway 4100 65 285 593 611 0.384 12 1

Ramp 1500 35 286 612 613 0.846 12 1

Ramp 1500 35 287 607 615 0.954 12 1

Ramp 1500 35 288 616 617 0.922 12 1

Ramp 1500 35 289 618 619 0.075 12 1

Major Arterial 1700 45 290 619 618 0.075 12 1

Major Arterial 1700 45 291 621 620 0.259 12 1

Ramp 1500 35 292 620 622 0.271 12 1

Ramp 1500 35 293 576 623 4.149 12 1

Major Arterial 1300 45 294 623 576 4.149 12 1

Major Arterial 1300 45 295 612 624 0.436 12 2

Collector / Local Road 3400 45 296 624 612 0.436 12 2

Collector / Local Road 3400 45 297 616 625 0.235 12 2

Principal Arterial 3320 45 298 626 625 0.408 12 1

Ramp 1500 35 299 620 627 0.656 12 2

Principal Arterial 3320 45 300 627 620 0.656 12 2

Principal Arterial 3320 45 301 628 627 1.325 12 1

Ramp 1500 35 302 629 630 0.462 12 1

Ramp 1500 35 303 627 629 0.205 12 2

Principal Arterial 3320 45 304 629 627 0.205 12 2

Principal Arterial 3320 45 305 631 606 1.391 12 1

Ramp 1500 35 306 633 634 0.214 11 1

Collector/ Local Road 1700 35 307 634 633 0.214 11 1

Collector! Local Road 1700 35 308 624 635 1.699 12 2

Minor Arterial 3400 45 309 635 624 1.699 12 2

Minor Arterial 3400 45 310 635 636 0.412 12 1

Collector/ Local Road 800 45 311 636 635 0.412 12 1

Collector!/ Local Road 800 45 312 634 639 0.8 12 1

Collector /Local Road 1700 45 313 639 634 0.8 12 1

Collector! Local Road 1700 45 314 644 645 0.065 12 1

Collector /Local Road 800 55 315 645 644 0.065 12 1

Collector! Local Road 800 55 316 644 646 0.052 12 1

Minor Arterial 1300 55 317 646 644 0.052 12 1

Minor Arterial 1300 55 318 632 648 2.935 12 1

Major Arterial 1300 55 319 648 632 2.935 12 1

Major Arterial 1300 55 320 352 648 0.365 12 1

Minor Arterial 1300 55 321 648 352 0.365 12 1

Minor Arterial 1300 55 322 351 648 0.545 12 1

Major Arterial 1300 55 323 648 351 0.545 12 1

Major Arterial 1300 55 324 638 651 3.301 12 2

Principal Arterial 3320 45 325 651 638 3.301 12 2

Principal Arterial 3320 45 326 659 660 0.12 12 1

Major Arterial 1300 55 327 660 659 0.12 12 1

Major Arterial 1300 55 328 665 666 1.209 12 1

Ramp 1500 35 329 668 667 1.357 12 1

Ramp 1500 35 330 670 671 3.068 12 1

Major Arterial 1300 45 331 671 670 3.068 12 1

Major Arterial 1300 45 332 667 672 1.239 12 1

Ramp 1500 35 333 673 665 1.284 12 1

Ramp 1500 35 334 131 674 0.017 12 1

Minor Arterial 1300 40 335 674 131 0.017 12 1

Minor Arterial 1300 40 Page 6 of 38 Page 6of 38Appendix C - Page 7 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Link #

U-Node D-Node Length Lane Number of Roadway Type Saturation Flow FFS (mph)

(ml)

Width (ft)

Lanes Rate (vehlhr) 336 130 674 0.052 12 1-Major Arterial 1300 45 337 674 130 0.052 12 1

Major Arterial 1300 45 338 661 676 0.578 12 1

Major Arterial 1300 45 339 676 661 0.578 12 1

Major Arterial 1300 45 340 661 662 0.013 12 1

Major Arterial 1300 45 341 662 661 0.013 12 1

Major Arterial 1300 45 342 493 677 0.08 12 1

Major Arterial.

1700 45 343 677 493 0.08 12 1

Major Arterial 1700

.45 344 678 679 0.085 12 1

Minor Arterial 1300 45 345 679 678 0.085 12 1

Minor Arterial 1300 45 346 572 680 0.039 12 2

Minor Arterial 3400 50 347 680 572 0.039 12 2

Minor Arterial 3400 50 348 678 680 0.198 12 2

Collector/ Local Road 2600 50 349 680 678 0.198 12 2

Collector / Local Road 2600 50 350 678 681 0.159 12 2

Minor Arterial 2600 50 351 681 678 0.159 12 2

Minor Arterial 2600 50 352 683 684 0.043 12 1

Minor Arterial 1700 45 353 684 683 0.043 12 1

Minor Arterial 1700 45 354 683 685 0.062 12 1

Minor Arterial 1300 45 355 685 683 0.062 12 1

Minor Arterial 1300 45 356 581 619 0.424 12 2

Principal Arterial 3320 45 357 619 581 0.424 12 2

Principal Arterial 3320 45 358 686 687 0.176 12 1

Freeway 2050 55 359 592 612 0.651 12 2

Minor Arterial 3400 45 360 612 592 0.651 12 2

Minor Arterial 3400 45 361 519 545 0.708 12 1

Minor Arterial 1300 55 362 545 519 0.708 12 1

Minor Arterial 1300 55 363 691 692 0.25 12 1

Principal Arterial 1700 55 364 692 691 0.25 12 1

Principal Arterial 1700 55 365 696 697 0.022 12 2

Principal Arterial 3320 40 366 703 704 0.002 12 1

Major Arterial 1300 45 367 704 703 0.002 12 1

Major Arterial 1300 45 368 710 711 0.183 12 1

Major Arterial 1300 45 369 711 710 0.183 12 1

Major Arterial 1300 45 370 714 715 0.414 12 2

Principal Arterial 3700 55 371 715 714 0.414 12 2

Principal Arterial 3700 55 372 717 718 0.67 12 1

Major Arterial 1300 55 373 718 717 0.67 12 1

Ma 'jor Arterial 1300 55 374 323 719 0.183 12 2

Principal Arterial 3700 55 375 484 493 0.151 12 1

Major Arterial 1300 45 376 493 484 0.151 12 1

Major Arterial 1300 45 377 495 494 0.544 12 2

Freeway 4100 65 378 600 620 0.157 12 2

Principal Arterial 3320 45 379 620 600 0.157 12 2

Principal Arterial 3320 45 380 617 607 0.167 12 2

Freeway 4100 65 381 604 616 0.042 12 2

Principal Arterial 3320 45 382 615 599 0.143 1

12 2

Principal Arterial 3320 45 383 631 729 0.032 12 2

Principal Arterial 3700 50 384 729 615 0.763 12 2

Principal Arterial 3320 45 385 556 730 0.086 12 2

Freeway 4100 65 386 730 536 0.077 12 2

Freeway 4100 65 387 560 558 0.066 1

12 1

Principal Arterial 1700 45 388 665 667 0.824 12 1

Major Arterial 1300 55 389 667 665 0.824 12 1

Major Arterial 1300 55 390 427 437 0.424 12

+

. 1 Ramp 1500 35 1 391 1 437 427 0.424 12 1

Ramp 1500 35 Page 7 of 38 Page 7of 38Appendix C - Page 8 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Length Lane Nmber o Roadwy Type Saturation Flow F(mh Link #

U-Node D-Node Lengt Laneh NumbLaersf RawyTp Rate (vehlhr)

FF(mh 392 723 183 0.861 12 2

Principal Arterial 3700 65 393 440 465 0.244 12 1

Minor Arterial 1700 40 394 715 736 0.291 12 2

Principal Arterial 3700 55 395 736 715 0.291 12 2

Principal Arterial 3700 55 396 380 404 1.005 12 1

Collector / Local Road 800 45 397 404 380 1.005 12 1

Collector / Local Road 800 45 398 397 741 1.631 12 1

Collector / Local Road 800 55 399 741 397 1.631 1

12 1

Collector / Local Road 800 55 400 663 669 1.499 12 1

Major Arterial 1300 45 401 669 663 1.499 12 1

Major Arterial 1300 45 402 727 752 1.197 12 11 Major Arterial 1300 55 403 752 727 1.197 12 1

Major Arterial 1300 55 404 704 717 0.153 12 1

Major Arterial 1300 35 405 717 704 0.153 12 1

Major Arterial 1300 35 406 578 632 1.005 12 1

Major Arterial 1300 55 407 632 578 1.005 12 1

Major Arterial 1300 55 408 547 755 0.295 12 1

Major Arterial 1300 55 409 755 547 0.295 12 1

Major Arterial 1300 55 410 574 577 3.229 12 1

Major Arterial 1300 55 411 577 574 3.229 12 1

Major Arterial 1300 55 412 286 736 0.38 1 12 2

Principal Arterial 3700 55 413 736 286 0.381 12 2

Principal Arterial 3700 55 414 728 757 0.1 12 2

Principal Arterial 3320 45 415 757 728 0.1 12 2

Principal Arterial 3320 45 416 645 646 0.092 12 1

Major Arterial 1300 55 417 646 645 0.092 12 1

Major Arterial 1300 55 418 509 763 0.05 12 1

Minor Arterial 1700 30 419 763 509 0.05 12 1

Minor Arterial 1700 30 420 124 420 0.14 12 2

Freeway 4100 55 421 426 767 0.063 12 1

Major Arterial 1700 45 422 767 426 0.063 12 1

Major Arterial 1700 45 423 396 768 0.821 12 1

Major Arterial 1300 55 424 768 396 0.821 12 1-Major Arterial 1300 55 425 768 769 0.19 12 1Major Arterial 1300 55 426 769 768 0.19 12 1Major Arterial 1300 55 427 369 770 0.845 12 1Major Arterial 1300 45 428 770 369 0.845 12 1Major Arterial 1300 45 429 283 771 0.091 12 1Principal Arterial 1600 45 430 771 283 0.091 12 1Principal Arterial 1600 45 431 772 773 0.348 12 1Major Arterial 1300 55 432 773 772 0.348 12 1

Major Arterial 1300 55 433 368 772 0.068 12 1

Major Arterial 1700 55 434 772 368 0.068 12 1

Major Arterial 1700 55 435 235 236 1.493 12 1

Major Arterial 1300 55 436 236 235 1.493 12 1

Major Arterial 1300 55 437 254 774 0.172 12 1

Principal Arterial 1600 45 438 774 254 0.172 12 1

Principal Arterial 1600 45 439 370 775 0.886 12 1

Principal Arterial 1600 551 440 775 370 0.886 12 1

Principal Arterial 1600 55 441 256 400 1.381 12 1

Principal Arterial 1600 55 442 1

400 256 1.381 12 1

Principal Arterial 1600 55 443 778 779 0.066 12 1

Major Arterial 1300 45 444 779 778 0.066 12 1

Major Arterial 1300 45 445 291 779 0.153 12 1

Major Arterial 1300 55 446 779 291 0.153 12 1

Major Arterial 1300 55 447 385 408 3.294 12 1

Major Arterial 1300 55 Page 8 of 38 Page 8of 38Appendix C - Page 9 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Lik#

UNd

-oe Length Lane Number of Roda ye Saturation Flow F(mh Link#

UNod D-ode (ml)

Width (ft)

Lanes Roda ye Rate (vehlhr) 448 408 385 3.294 12 1

Major Arterial 1300 55 449 416 781 0.049 12 1

Major Arterial 1300 45 450 781 416 0.049 12 1

Major Arterial 1300 45 451 318 782 0.088 12 1

Principal Arterial 1600 45 452 782 318 0.088 12 1

Principal Arterial 1600 45 453 783 323 0.183 12 2

Principal Arterial 3700 55 454 656 660 0.217 12 1

Major Arterial 1300 55 455 660 656 0.217 12 1

Major Arterial 1300 55 456 647 788 2.97 12 1

Major Arterial 1700 55 457 788 647 2.97 12 1

Major Arterial 1700 55 458 513 789 0.256 12 1

Major Arterial 1300 45 459 789 513 0.256 12 1

Major Arterial 1300 45 460 205 792 0.41 1

12 1

Major Arterial 1700 45 461 792 205 0.41 12 1

Major Arterial 1700 45 462 409 792 0.39 12 1

Major Arterial 1700 35 463 792 409 0.39 12 1

Major Arterial 1700 35 464 793 794 0.314 12 1

Major Arterial 1700 55 465 794 793 0.314 12 1

Major Arterial 1700 55 466 360 361 0.862 12 1

Major Arterial 1300 55 467 361 360 0.862 12 1

Major Arterial 1300 55 468 360 657 13.836 12 1

Principal Arterial 1600 55 469 657 360 13.836 12 1

Principal Arterial 1600 55 470 134 795 0.846 12 1

Principal Arterial 1600 45 471 795 134 0.846 12 1

Principal Arterial 1600 45 472 355 795 0.05 12 1

Principal Arterial 1600 30 473 795 355 0.05 12 1

Principal Arterial 1600 30 474 386 796 0.076 12 1

Major Arterial 1300 45 475 796 386 0,076 12 1-Major Arterial 1300 45 476 186 797 0.285 12 2

Principal Arterial 2800 30 477 410 186 0.319 12 2

Principal Arterial 2800 30 478 675 747 0.257 12 1

Minor Arterial 1700 30 479 747 675 0.257 12 1

Minor Arterial 1700 30 480 523 801 0.077 12 1

Minor Arterial 1700 40 481 801 523 0.077 12 1

Minor Arterial 1700 40 482 681 802 1.24 12 2

Collector/ Local Road 2600 50 483 802 681 1.24 12 2

Collector/ Local Road 2600 50 484 802 803 0.155 12 1

Collector/ Local Road 1700 45 485 803 802 0.155 12 1

Collector/ Local Road 1700 45 486 638 804 0.7 18 12 2

Principal Arterial 3320 45 487 804 638 0.718 12 2

Principal Arterial 3320 45 488 561 810 0.009 12 1

Minor Arterial 1700 40 489 810 561 0.009 12 1 -Minor Arterial 1700 40 490 810 811 0.114 12 1

Principal Arterial 1700 45 491 812 555 0.059 12 2

Freeway 4100 65 492 571 813 0.243 12 1

1 Ramp 1500 35 493 814 812 0.314 12 1

Ramp 1500 35 494 573 815 0.48 12 1

Ramp 1500 35 495 814 815 0.213 12 1

Principal Arterial 1700 45 496 813 814 0.074 12 1

Principal Arterial 1700 45 497 816 570 0.356 12 1

Ramp 1500 35 498 816 813 0.211 12 1

Minor Arterial 1700 40 499 513 817 0.952 12 1

Major Arterial 1300 45 500 817 513 0.952 12 1

Major Arterial 1300 45 501 818 819 0.263 12 1

Collector/ Local Road 1300 55 502 819 818 0.263 12 1

Collector /Local Road 1300 55 503 820 445 0.008 12 1

Collector/ Local Road 1700 40 Page 9 of 38 Page 9of 38Appendix C - Page 10 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Link #

U-Node D-Node Length Lane Number of Roadway Type Saturation Flow FFS (mph)

(mi)

Width (ft)

Lanes Rate (vehlhr) 504 821 448 0.065 12 1

Minor Arterial 1700 40 505 820 821 0.019 12 1

Minor Arterial 1700 40 506 445 821 0.012 12 1

Collector/ Local Road 1700 40 507 481 489 0.063 12 1

Principal Arterial 1700 45 508 489 481 0.063 12 1

Principal Arterial 1700 45 509 143 198 0.769 12 1

Major Arterial 1300 40 510 198 196 0.048 12 1

Major Arterial 1300 40 511 197 199 0.011 12 1

Major Arterial 1300 40 512 199 137 0.092 12 1

Major Arterial 1300 40 513 210 824 1.004 12 1

Principal Arterial 1600 55 514 824 210 1.004 12 1

Principal Arterial 1600 55 515 214 825 0.732 12 1

Major Arterial 1300 55 516 825 214 0.732 12 1

Major Arterial 1300 55 517 656 663 4.306 12 1

Collector / Local Road 1300 45 518 663 656 4.306 12 1

Collector/ Local Road 1300 45 519 828 561 0.249 12 1

Principal Arterial 1600 45 520 339 390 0.25 12 1

Major Arterial 1300 30 521 390 339 0.25 12 1

Major Arterial 1300 30 522 257 776 0.066 12 1

Principal Arterial 1700 55 523 776 257 0.066 12 1

Principal Arterial 1700 55 524 328 329 0.065 12 2

Principal Arterial 3320 40 525 329 328 0.065 12 1

Principal Arterial 3320 30 526 756 832 0.033 12 1

Major Arterial 1700 55 527 832 756 0.033 12 1

Major Arterial 1700 55 528 685 835 0.112 12 1

Major Arterial 1300 45 529 835 685 0.112 12 1

Major Arterial 1300 45 530 677 817 0.235 12 1

Major Arterial 1300 45 531 817 677 0.235 12 1

Major Arterial 1300 45 532 508 836 0.129 12 1 _

Major Arterial 1300 35 533 836 508 0.129 12 1

Major Arterial 1300 35 534 507 836 0.303 12 1

Major Arterial 1300 45 535 836 507 0.303 12 1

Major Arterial 1300 45 536 641 837 0.174 12 2

Minor Arterial 3400 40 537 837 641 0.174 12 2

Minor Arterial 3400 40 538 653 722 0.231 12 2

Principal Arterial 3320 45 539 722 653 0.231 12 2

Principal Arterial 3320 45 540 597 805 0.882 12 1

Ramp 1500 55 541 579 583 0.249 12 2

Minor Arterial 3400 40 542 583 579 0.249 12 2

Minor Arterial 3400 40 543 589 604 0.2 12 2

Principal Arterial 3320 45 544 747 803 0.195 12 1

Minor Arterial 1700 45 545 803 747 0.195 12 1

Minor Arterial 1700 45 546 542 803 0.725 12 1

Major Arterial 1700 45 547 803 542 0.725 12 1

Major Arterial

___1700 45 548 460 840 0.081 12 1

Minor Arterial 1700 40 549 448 840 0.071 12 1

Minor Arterial

___1700 40 550 840 448 0.071 12 1

Minor Arterial 1700 40 551 840 465 0.2 12 2

Minor Arterial 3400 40 552 829 539 0.768 12 2

Freeway 4100 65 553 811 826 0.055 12 1

Principal Arterial 1600 45 554 438 843 0.063 12 2

Freeway 4100 65 555 470 844 0.051 12 1

Principal Arterial 1700 45 556 433 448 0.175 12 1

Minor Arterial 1700 40 557 448 433 0.175 12 1

Minor Arterial 1700 40 558 435 441 0.147 12 1

Principal Arterial 1700 45 559 441 435 0.147 12 1

1 Principal Arterial 1700 45 Page 10 of 38 Page10 o 38Appendix C -Page 11 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Link #

U-Node D-Node Length Lane Number of Roadway Type Ratraeio Felhow FFS (mph)

(mi)

Width (ft)

Lanes Rate________

560 573 812 0.256 12 2

Freeway 4100 65 561 559 571 0.065 12 2

Freeway 4100 65 562 609 610 0.046 12 2

Freeway 4100 65 563 461 460 0.213 12 1

Minor Arterial 1700 40 564 430.

433 0.03 12 1

Minor Arterial 1700 40 565 433 430 0.03 12 1

Minor Arterial 1700 40 566 431 432 0.063 12 1

Principal Arterial 1700 40 567 432 431 0.063 12 1

Principal Arterial 1700 40 568 789 848 0.378 12 1

Major Arterial 1700 45 569 848 789 0.378 12 1

Major Arterial 1700 45 570 164 849 0.496 12 2

Freeway 4100 65 571 850 99 0.502 12 2

Freeway 4100 65 572 391 393 0.078 1

12 1

Major Arterial 1300 45 573 393 391 0.078 12 1

Major Arterial 1300 45 574 273 274 0.114 12 1

Principal Arterial 1700 30 575 274 273 0.114 12 1

Principal Arterial 1700 30 576 263 406 0.006 12 1

Major Arterial 1700 45 577 406 263 0.006 12 1

Major Arterial 1700 45 578 266 407 0.005 12 1

Major Arterial 1300 45___

579 407 266 0.005 12 1

Major Arterial 1300 45___

580 261 372 0.504 12 1

Major Arterial 1300 55___

581 372 261 0.504 12 1

Major Arterial 1300 5

582 330 402 0.898 12 1

Major Arterial 1300 4

583 402 330 0.898 12 1

Major Arterial 1300 45___

584 331 847 0.012 12 1

Principal Arterial 1600 40____

585 847 331 0.012 12 1

Principal Arterial 1600 4

586 417 739 0.876 12 1

Major Arterial 1300 55 587 739 417 0.876 12 1

Major Arterial 1300 55 588 378 739 0.007 12 1

Major Arterial 1300 45 589 739 378 0.007 12 1

Major Arterial 1300 45 590 331 852 0.861 12 1

Major Arterial 1300 45 591 852 331 0.861 12 1

Major Arterial 1300 45 592 773 856 0.372 12 1

Major Arterial 1700 55 593 856 773 0.372 12 1

Major Arterial 1700 55 594 254 857 0.054 12 1

Major Arterial 1300 45 595 857 254 0.054 12 1

Major Arterial 1300 45 596 388 846 0.519 12 1

Major Arterial 1700 55 597 846 388 0.519 12 1

Major Arterial 1700 55 598 407 860 0.399 12 1

Major Arterial 1300 55 599 860 407 0.399 12 1

Major Arterial 1300 55 600 405 786 1.328 12 1

Collector/ Local Road 800 45 601 786 405 1.328 12 1

Collector /Local Road 800 45 602 392 787 0.002 12 1

Major Arterial 1300 45 603 787 392 0.002 12 1

Major Arterial 1300 45 604 708 861 0.148 12 1

Major Arterial 1300 45 605 861 708 0.148 12 1

Major Arterial 1300 45 606 737 862 0.165 12 1

Principal Arterial 1600 30 607 862 737 0.165 12 1

Principal Arterial 1600 30 608 864 865 0.006 12 1

Major Arterial 1700 45 609 865 864 0.006 12 1

Major Arterial 1700 45 610 718 866 0.141 12 1

Major Arterial 1300 55 611 866 718 0.141 12 1

Major Arterial 1300 55 612 738 868 0.827 12 1

Collector / Local Road 800 45 613 868 738 0.827 12 1

Collector / Local Road 800 45 614 869 870 0.002 12 1

Major Arterial 1300 45 615 870 869 0.002 121 Major Arterial 1300 45 Page 11 of 38 Page11 o 38Appendix C - Page 12 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Link #

U-Node D-Node Length Lane Number of Roadway Type Saturation Flow FFS (mph)

S_________

(mi)

Width (ft)

Lanes Rate (vehlhr) 616 752 870 0.055 12 1

Major Arterial 1300 30 617 870 752 0.055 12 1

Major Arterial 1300 30 618 697 871 0.104 12 2

Principal Arterial 3320 40 619 871 697 0.104 12 2

Principal Arterial 3320 40 620 714 872 0.471 12 1

Principal Arterial 1600 55 621 872 714 0.471 12 1

Principal Arterial 1600 55 622 872 873 0.057 12 1

Principal Arterial 1600 55 623 873 872 0.057 12 1

Principal Arterial 1600 55 624 728 874 0.529 12 1

Principal Arterial 1600 55 625 874 728 0.529 12 1

Principal Arterial 1600 55 626 873 874 0.043 12 1

Principal Arterial 1600 55 627 874 873 0.043 12 1

Principal Arterial 1600 55 628 875 872 0.019 12 1

Collector! Local Road 1300 40 629 874 875 0.021 12 1

Collector! Local Road 1300 40 630 873 875 0.042 12 1

Major Arterial 1300 55 631 875 873 0.042 12 1

Major Arterial 1300 55 632 876 877 0.106 12 1

Major Arterial 1300 45 633 877 876 0.106 12 1

Major Arterial 1300 45 634 725 824 0.004 12 2

Principal Arterial 3320 45 635 824 725 0.004 12 2

Principal Arterial 3320 45 636 701 807 1.394 12 1

Major Arterial 1300 55 637 807 701 1.394 12 1

Major Arterial 1300 55 638 125 879 0.268 12 2

Principal Arterial 3700 65 639 126 880 0.117 12 2

Principal Arterial 3700 55 640 876 878 0.178 12 1 _

Major Arterial 1300 45 641 878 876 0.178 12 1

Major Arterial 1300 45 642 330 881 0.222 12 1

Principal Arterial 1600 40 643 881 330 0.222 12 1

Principal Arterial 1600 40 644 227 882 3.436 10 1 _

Collector / Local Road 800 15 645 882 227 3.436 10 1

Collector! Local Road 800 15 646 227 883 3.477 10 1

Collector/ Local Road 800 15 647 883 227 3.477 10 1 _

Collector! Local Road 800 15 648 367 885 2.543 10 1

Collector! Local Road 800 15 649 885 367 2.543 10 1

Collector! Local Road 800 15 650 215 886 5.778 10 1

Collector/!Local Road 800 15 651 886 215 5.778 10 1

Collector!/Local Road 800 15 652 221 887 3.121 10 1

Collector!/Local Road 800 15 653 887 221 3.121 10 1 _

Collector!/Local Road 800 15 654 194 888 3.511 10 1

Collector!/ Local Road 800 15 655 888 194 3.511 10 1

Collector! Local Road 800 15 656 253 890 0.742 10 1

Collector! Local Road 800 15 657 890 253 0.742 10 1

Collector/!Local Road 800 15 658 235 890 0.835 10 1

Collector!/ Local Road 800 15 659 890 235 0.835 10 1

Collector! Local Road 800 15 660 400 891 0.739 10 1

Collector! Local Road 800 15 661 891 400 0.739 10 1

Collector!/ Local Road 800 15 662 236 891 2.099 10 1

Collector/!Local Road 800 15 663 891 236 2.099 10 1

Collector!/Local Road 800 15 664 287 892 1.847 10 1 ___Collector!/Local Road 800 15 665 892 287 1.847 10 1

Collector! Local Road 800 15 666 298 893 2.408 10 1

Collector!/ Local Road 800 15 667 893 298 2.408 10 1

Collector/!Local Road 800 15 668 866 895 0.279 10 1

Collector / Local Road 800 15 669 895 866 0.279 10 1

Collector! Local Road 800 15 670 718 895 0.452 10 1

Collector! Local Road 800 15 671 895 718 0.452 10 1

Collector!/ Local Road 800 15 Page 12 of 38 Page12 o 38Appendix C - Page 13 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Link #

U-Node D-Node Legh Ln ubro oda ye Saturation Flow F(mh Lengt Laneh NumbLaersf RawyTp Rate (vehlhr)

S(mh 672 895 896 5.17 10 1

Collector / Local Road 800 15 673 896 895 5.17 10 1

Collector / Local Road 800 15 674 278 898 1.945 10 1

Collector / Local Road 800 15 675 898 278 1.945 10 1

Collector / Local Road 800 15 676 279 899 2.483 10 1

Collector / Local Road 800 15 677 899 279 2.483 10 1

Collector /Local Road 800 15 678 269 900 3.722 10 1

Collector / Local Road 800 15 679 900 269 3.722 10 1

Collector / Local Road 800 15 680 240 901 3.76 10 1

Collector / Local Road 800 15 681 901 240 3.76 10 1

Collector / Local Road 800 15 682 369 902 4.757 10 1

Collector / Local Road 800 15 683 902 369 4.757 10 1

Collector / Local Road 800 15 684 231 903 0.605 10 1

Collector / Local Road 800 15 685 903 231 0.605 10 1

Collector / Local Road 800 15 686 248 903 1.009 10 1

Collector /Local Road 800 15 687 903 248 1.009 10 1

Collector /Local Road 800 15 688 402 904 1.361 10 1

Collector /Local Road 800 15 689 904 402 1.361 10 1

Collector/ Local Road 800 15 690 331 904 0.863 10 1

Collector/ Local Road 800 15 691 904 331 0.863 10 1

Collector / Local Road 800 15 692 326 905 0.585 10 1

1 Collector/ Local Road 800 15 693 905 326 0.585 10 1

Collector / Local Road 800 15 694 332 905 0.427 10 1

Collector / Local Road 800 15 695 905 332 0.427 10 1

Collector / Local Road 800 15 696 387 906 2.55 10 1

Collector / Local Road 800 15 697 906 387 2.55 10 1

Collector/ Local Road 800 15 698 409 909 1.535 10 1

Collector/ Local Road 800 15 699 909 409 1,535 10 1

Collector/ Local Road 800 15 700 388 910 2.296 10 1

Collector / Local Road 800 15 701 910 388 2.296 10 1

Collector/ Local Road 800 15 702 414 912 1.091 10 1

Collector /Local Road 800 15 703 912 414 1.091 10 1

Collector/ Local Road 800 15 704 204 913 4.758 10 1

Collector/ Local Road 800 15 705 913 204 4.758 10 1

Collector / Local Road 800 15 706 741 914 1.98 10 1

Collector/ Local Road 800 15 707 914 741 1.98 10 1

Collector /Local Road 800 15 708 349 916 1.849 10 1

Collector /Local Road 800 15 709 916 349 1.849 10 1

Collector/ Local Road 800 15 710 344 917 2.464 10 1

Collector/ Local Road 800 15 711 917 344 2.464 10 1

Collector /Local Road 800 15 712 356 918 1.886 10 1

Collector /Local Road 800 15 713 918 356 1.886 10 1

Collector /Local Road 800 15 714 644 921 2.7 10 1

Collector/ Local Road 800 15 715 921 644 2.7 10 1

Collector / Local Road 800 15 716 632 922 3.432 10 1

Collector/ Local Road 800 15 717 922 632 3.432 10 1

Collector / Local Road 800 15 718 350 923 2.513 10 1

Collector/ Local Road 800 15 719 923 350 2.513 10 1

Collector / Local Road 800 15 720 547 924 2.166 10 1

Collector/ Local Road 800 15 721 924 547 2.166 10 1

Collector /Local Road 800 15 722 698 925 6.131 10 1

Collector / Local Road 800 15 723 925 698 6.131 10 1

Collector / Local Road 800 15 724 178 926 3.258 10 1

Collector/ Local Road 800 15 75 926 178 3.258 10 1

Collector /Local Road 800 15 76 321 928 0.595 10 1

Collector / Local Road 800 15 77 928 321 0.595 10 1

Collector / Local Road 800 15 Page 13 of 38 Page13 o 38Appendix C - Page 14 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Link #

U-Node D-Node Length Lane Number of Roadway Type Saturation Flow FFS (mph)

(mi)

Width (ft)

Lanes Rate (vehlhr) 728 308 928 0.366 10 1

Collector / Local Road 800 15 729 928 308 0.366 10 1

Collector/ Local Road 800 15 730 310 929 4.818 10 1

Collector/ Local Road 800 15 731 929 310 4.818 10 1

Collector/ Local Road 800 15 732 743 931 2.12 10 1

Collector/ Local Road 800 15 733 931 743 2.12 10 1

Collector /Local Road 800 15 734 404 932 2.537 10 1

Collector / Local Road 800 15 735 932 404 2.537 10 1

Collector /Local Road 800 15 736 382 934 3.161 10 1

CollectorlILocal Road 800 15 737 934 382 3.161 10 1

Collector/ Local Road 800 15 738 401 935 4.512 10 1

Collector/ Local Road 800 15 739 935 401 4.512 10 1

Collector /Local Road 800 15 740 312 938 2.289 10 1

Collector I Local Road 800 15 741 938 312 2.289 10 1

Collector /Local Road 800 15 742 389 939 2.309 10 1

Collector / Local Road 800 15 743 939 389 2.309 10 1

Collector/ Local Road 800 15 744 643 941 0.81 10 1

Collector / Local Road 800 15 745 941 643 0.81 10 1

Collector /Local Road 800 15 746 831 942 2.633 10 1

Collector /Local Road 800 15 747 942 831 2.633 10 1

Collector /Local Road 800 15 748 650 943 1.901 10 1

Collector /Local Road 800 15 749 943 650 1.901 10 1

Collector / Local Road 800 15 750 653 944 0.931 10 1

Collector/ Local Road 800 15 751 944 653 0.931 10 1

Collector / Local Road 800 15 752 641 945 1.738 12 1

Principal Arterial 1600 55 753 945 641 1.738 12 1

Principal Arterial 1600 55 754 663 946 0.816 10 1

Collector/ Local Road 800 15 755 946 663 0.816 10 1

Collector/ Local Road 800 15 756 660 947 0.644 12 1

Collector / Local Road 800 45 757 947 660 0.644 12 1

Collector/ Local Road 800 45 758 640 949 3.215 10 1

Collector /Local Road 800 15 759 949 640 3.215 10 1

Collector /Local Road 800 15 760 588 950 0.716 12 1

Minor Arterial 1300 55 761 950 588 0.716 12 1

Minor Arterial 1300 55 762 567 950 0.339 12 1

Minor Arterial 1300 55 763 950 567 0.339 12 1

Minor Arterial 1300 55 764 623 951 0.219 12 1

Collector/ Local Road 800 45 765 951 623 0.219 12 1

Collector / Local Road 800 45 766 504 952 2.43 10 1

Collector/ Local Road 800 15 767 952 504 2.43 10 1

Collector/ Local Road 800 15 768 498 953 0.448 10 1

Collector /Local Road 800 15 769 953 498 0.448 10 1

Collector / Local Road 800 15 770 318 954 2.133 10 1

Collector/ Local Road 800 15 771 954 318 2.133 10 1

Collector/ Local Road 800 15 772 689 955 1.762 10 1

Collector/ Local Road 800 15 773 955 689 1.762 10 1

Collector /Local Road 800 15 774 418 723 28.75 12 2

Principal Arterial 3700 65 775 386 957 3.493 10 1

Collector / Local Road 800 15 776 957 386 3.493 10 1

Collector/ Local Road 800 15 777 764 761 0.05 10 1

Collector / Local Road 800 15 778 761 958 0.37 10 1

Collector / Local Road 800 15 779 958 761 0.37 10 1

Collector / Local Road 800 15 780 1

882 0.482 10 1

Collector/ Local Road 800 25 781 882 1

0.482 10 1

Collector / Local Road 800 25 782 2

884 0.66 10 1

Collector / Local Road 800 25 783 884 2

0.66 10 1

Collector / Local Road 800 25 Page 14 of 38 Page14 o 38Appendix C - Page 15 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Lik#

UNd

-oe Length Lane Number of Roda ye Saturation Flow F(mh Link#

UNod D-ode (ml)

Width (ft)

Lanes Roda ye Rate (vehlhr) 784 3

365 0.857 10 1

Collector / Local Road 800 25 785 365 3

0.857 10 1

Collector / Local Road 800 25 786 4

883 0.433 10 1

Collector! Local Road 800 25 787 883 4

0.433 10 1

Collector! Local Road 800 25 788 5

889 0.312 10 1

Collector!/ Local Road 800 25 789 889 5

0.3 12 10 1

Collector / Local Road 800 25 790 6

768 1.579 10 1

Collector/ILocal Road 800 25 791 768 6

1.579 10 1

Collector! Local Road 800 25 792 7

903 0.216 10 1

Collector!/ Local Road 800 25 793 903 7

0.216 10 1

Collector / Local Road 800 25 794 8

890 0.529 10 1

Collector!/ Local Road 800 25 795 890 8

0.529 10 1

Collector!/ Local Road 800 25 796 9

252 1.191 10 1

Collector! Local Road 800 25 797 252 9

1.191 10 1

Collector! Local Road 800 25 796 10 766 1.514 10 1

Collector/ Local Road 800 25 799 766 10 1.514 10 1

Collector/ Local Road 800 25 800 11 902 0.316 10 1

Collector!/ Local Road 800 25 801 902 11 0.316 10 1

Collector! Local Road 800 25 802 12 899 0.814 10 1

Collector!/ Local Road 800 25 803 899 12 0.814 10 1

Collector!/ Local Road 800 25 804 13 898 0.396 10 1

Collector /Local Road 800 25 805 898 13 0.396 10 1

Collector /Local Road 800 25 806 14 918 0.272 10 1

Collector/ Local Road 800 25 807 918 14 0.272 10 1

Collector!/ Local Road 800 25 808 15 334 1.729 10 1

Collector / Local Road 800 25 809 334 15 1.729 10 1

Collector/ILocal Road 800 25 810 16 956 0.251 10 1

Collector /Local Road 800 25 811 956 16 0.251 10 1

Collector/ Local Road 800 25 812 17 919 0.41 10 1

Collector! Local Road 800 25 813 919 17 0.41 10 1

Collector!/ Local Road 800 25 814 18 920 0.744 10 1

Collector/ Local Road 800 25 815 920 18 0.744 10 1

Collector /Local Road 800 25 816 19 914 0.855 10 1

Collector /Local Road 800 25 817 914 19 0.855 10 1

Collector! Local Road 800 25 818 20 399 1.327 10 1

Collector! Local Road 800 25 819 399 20 1.327 10 1

Collector! Local Road 800 25 820 21 891 1.287 10 1

Collector!/ Local Road 800 25 821 891 21 1.287 10 1

Collector/ Local Road 800 25 822 22 927 0.863 10 1

Collector / Local Road 800 25 823 927 22 0.863 10 1

Collector! Local Road 800 25 824 23 893 1.365 10 1

Collector! Local Road 800 25 825 893 23 1.365 10 1

Collector! Local Road 800 25 826 24 904 0.542 10 1

Collector / Local Road 800 25 827 904 24 0.542 10 1

Collector / Local Road 800 25 828 25 905 0.17 10 1

Collector / Local Road 800 25 829 905 25 0.17 10 1

Collector! Local Road 800 25 830 26 892 1.395 10 1

Collector! Local Road 800 25 831 892 26 1.395 10 1

Collector/ Local Road 800 25 832 27 285 1.819 10 1

Collector /Local Road 800 25 833 285 27 1.819 10 1

Collector /Local Road 800 25 834 28 928 0.121 10 1

Collector! Local Road 800 25 835 928 28 0.121 10 1

Collector!/ Local Road 800 25 836 29 957 1.499 10 1

Collector / Local Road 800 25 837 957 29 1.499 10 1

Collector /Local Road 800 25 838 30 363 2.016 10 1

Collector! Local Road 800 25 839 363 30 2.016 10 1

collector! Local Road 800 25 Page 15 of 38 Page15 o 38Appendix C - Page 16 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Lik#

UNd

-oe Length Lane Number of Roadway Type Ratraeio Felhrw

___(mph)

Link#

UNod D-ode (mi)

Width (ft)

Lanes Satattio FlowFF5 mph 840 31 916 1.647 10 1

Collector /Local Road 800 25 841 916 31 1.647 10 1

Collector /Local Road 800 25 842 32 917 0.278 10 1

Collector / Local Road 800 25 843 917 32 0.278 10 1

Collector/ Local Road 800 25 844 33 915 1.081 10 1

Collector/ Local Road 800 25 845 915 33 1.081 10 1

Collector/ Local Road 800 25 846 34 936 0.45 10 1

Collector / Local Road 800 25 847 936 34 0.45 10 1

Collector /Local Road 800 25 848 35 319 2.866 10 1

Collector / Local Road 800 25 849 319 35 2.866 10 1

Collector/ Local Road 800 25 850 36 907 0.525 10 1

Collector/ Local Road 800 25 851 907 36 0.525 10 1

Collector / Local Road 800 25 852 37 906 0.441 10 1

Collector / Local Road 800 25 853 906 37 0.441 10 1

Collector / Local Road 800 25 854 38 929 0.898 10 1

Collector / Local Road 800 25 855 929 38 0.898 10 1

Collector / Local Road 800 25 856 39 931 2.199 10 1

Collector/ Local Road 800 25 857 931 39 2.199 10 1

Collector/ Local Road 800 25 858 40 930 0.647 10 1

Collector / Local Road 800 25 859 930 40 0.647 10 1

Collector / Local Road 800 25 860 41 394 0.801 10 1

Collector t Local Road 800 25 861 394 41 0.801 10 1

Collector/ Local Road 800 25 862 42 935 0.995 10 1

Collector/ Local Road 800 25 863 935 42 0.995 10 1

Collector/ Local Road 800 25 864 43 934 0.806 10 1

Collector/ Local Road 800 25 865 934 43 0.806 10 1

Collector /Local Road 800 25 866 44 954 0.279 10 1

Collector/ Local Road 800 25 867 954 44 0.279 10 1

Collector/ Local Road 800 25 868 45 947 0.187 10 1

Collector/ Local Road 800 25 869 947 45 0.187 10 1

Collector/I Local Road 800 25 870 46 669 1.562 10 1

Collector/ Local Road 800 25 871 669 46 1.562 10 1

Collector/ Local Road 800 25 872 47 946 0.493 10 1

Collector / Local Road 800 25 873 946 47 0.493 10 1

Collector / Local Road 800 25 874 48 948 0.571 10 1

Collector/I Local Road 800 25 875 948 48 0.571 10 1

Collector/ Local Road 800 25 876 49 951 1.357 10 1

Collector/ Local Road 800 25 877 951 49 1.357 10 1

Collector/ Local Road 800 25 878 50 921 0.38 10 1

Collector / Local Road 800 25 879 921 50 0.38 10 1

Collector /Local Road 800 25 880 51 922 0.34 10 1

Collector / Local Road 800 25 881 922 51 0.34 10 1

Collector/ Local Road 800 25 882 52 923 0.343 10 1

Collector/ Local Road 800 25 883 923 52 0.343 1

10 1

Collector / Local Road 800 25 884 53 933 0.514 10 1

Collector/ Local Road 800 25 885 933 53 0.514 10 1

Collector / Local Road 800 25 886 54 405 2.342 10 1

Collector/ Local Road 800 25 887 405 54 2.342 10 1

Collector/ Local Road 800 25 888 55 932 1.717 10 1

Collector/ Local Road 800 25 889 932 55 1.717 10 1

Collector/ Local Road 800 25 890 56 955 1.203 10 1

Collector / Local Road 800 25 891 955 56 1.203 10 1

Collector/ Local Road 800 25 892 57 909 0.208 10 1

Collector / Local Road 800 25 893 909 57 0.208 10 1

Collector / Local Road 800 25 894 58 1

910 0.172 10 1

Collector/ Local Road 800 25 895 910 1

58 0.172 10 1

Collector /Local Road 800 25 Page 16 of 38 Page16 o 38Appendix C - Page 17 of 44

.Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Lik#

UNd

-oe Length Lane Number of Roda ye Saturation Flow F(mh Link#

UNod D-ode (ml)

Width (ft)

Lanes Roda ye Rate (vehlhr)FS(mh 896 59 908 0.13 10 1

Collector / Local Road 800 25 897 908 59 0.13 10 1

Collector / Local Road 800 25 898 60 412 0.456 10 1

Collector!I Local Road 800 25 899 412 60 0.456 10 1

Collector!/ Local Road 800 25 900 61 912 0.682 10 1

Collector / Local Road 800 25 901 912 61 0.682 10 1

Collector I Local Road 800 25 902 62 911 0.896 10 1

Collector / Local Road 800 25 903 911 62 0.896 10 1

Collector! Local Road 800 25 904 63 913 0.574 10 1

Collector / Local Road 800 25 905 913 63 0.574 10 1

Collector /Local Road 800 25 906 64 867 1.043 10 1

Collector! Local Road 800 25 907 867 64 1.043 10 1

Collector / Local Road 800 25 908 65 896 0.203 10 1

Collector!/ Local Road 800 25 909 896 65 0.203 10 1

Collector!/ Local Road 800 25 910 66 868 0.646 10 1

Collector / Local Road 800 25 911 868 66 0.646 10 1

Collector/ Local Road 800 25 912 67 894 0.685 10 1

Collector!/ Local Road 800 25 913 894 67 0.685 10 1

Collector I Local Road 800 25 914 68 897 1.69 10 1

Collector /Local Road 800 25 915 897 68 1.69 10 1

Collector! Local Road 800 25 916 69 900 0.665 10 1

Collector / Local Road 800 25 917 900 69 0.665 10 1

Collector!/ Local Road 800 25 918 70 901 1.347 10 1

Collector /Local Road 800 25 919 901 70 1.347 10 1

Collector/ILocal Road 800 25 920 71 888 1.576 10 1

Collector!/ Local Road 800 25 921 888 71 1.576 10 1

Collector!/ Local Road 800 25 922 72 887 0.206 10 1

Collector! Local Road 800 25 923 887 72 0.206 10 1

Collector!/ Local Road 800 25 924 73 886 0.989 10 1

Collector!/ Local Road 800 25 925 886 73 0.989 10 1

Collector!/ Local Road 800 25 926 74 885 0.776 10 1

Collector! Local Road 800 25 927 885 74 0.776 10 1

Collector! Local Road 800 25 928 75 926 0.915 10 1

Collector! Local Road 800 25 929 926 75 0.915 10 1

Collector!/ Local Road 800 25 930 76 925 1.125 10 1

Collector!/ Local Road 800 25 931 925 76 1.125 10 1

Collector! Local Road 800 25 932 77 924 0.175 10 1

Collector! Local Road 800 25 933 924 77 0.175 10 1

Collector! Local Road 800 25 934 78 953 0.051 10 1

Collector!/ Local Road 800 25____

935 953 78 0.051 10 1

Collector!/ Local Road 800 25___

936 79 952 0.447 10 1

Collector!/ Local Road 800 2

937 952 79 0.447 10 1

Collector! Local Road 800 25___

938 80 545 0.909 10 1

Collector!/ Local Road 800 25___

939 545 80 0.909 10 1

Collector!/ Local Road 800 25___

940 81 514 0.222 10 1

Collector!/ Local Road 800 25___

941 514 81 0.222 10 1

Collector /Local Road 800 2

942 82 950 0.506 10 1

Collector! Local Road 800 25 943 950 82 0.506 10 1

Collector!/ Local Road 800 25 944 83 949 1.25 10 1

Collector!/ Local Road 800 25 945 949 83 1.25 10 1

Collector /Local Road 800 25 946 84 945 0.758 1

10 1

Collector! Local Road 800 25 947 945 84 0.758 10 1

Collector! Local Road 800 25 948 85 944 0.08 10 1

Collector!/ Local Road 800 25 949 944 85 0.08 10 1

Collector!/ Local Road 800 25 950 86 943 0.441 10 1

collector! Local Road 800 25 951 943 86 0.441

-10 1

Collector! Local Road 800 25 Page 17 of 38 Page17 o 38Appendix C - Page 18 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Lik UNoe

-Nde Length Lane Number of Roadway Type Ratraeio Fvelowhr(ph Link#

UNod D-ode (ml)

Width (ft)

Lanes Satattio FlowFF5 mph 952 87 942 0.614 10 1

Collector /Local Road 800 25 953 942 87 0.614 10 1

Collector / Local Road 800 25 954 88 940 1.192 10 1

Collector/ Local Road 800 25 955 940 88 1.192 10 1

Collector/ Local Road 800 25 956 89 939 0.192 10 1

Collector I Local Road 800 25 957 939 89 0.192 10 1

Collector / Local Road 800 25 958 90 938 1.243 10 1

Collector /Local Road 800 25 959 938 90 1.243 10 1

Collector /Local Road 800 25 960 91 937 1.113 10 1

Collector /Local Road 800 25 961 937 91 1.113 10 1

Collector /Local Road 800 25 962 92 325 0.712 10 1

Collector/ Local Road 800 25 963 325 92 0.712 10 1

Collector / Local Road 800 25 964 93 958 0.601 10 1

Collector/ Local Road 800 25 965 958 93 0.601 10 1

Collector/ Local Road 800 25 966 94 690 0.441 10 1

Collector/ Local Road 800 25 967 690 94 0.441 10 1

Collector/ Local Road 800 25 968 95 941 0.393 10 1

Collector/ Local Road 800 25 969 941 95 0.393 10 1

Collector / Local Road 800 25 970 175 959 2.053 12 2

Freeway 4100 65 971 960 112 1.316 12 2

Freeway 4100 65 972 818 96 0.879 12 2

Principal Arterial 3700 55 973 880 818 0.869 12 2

Principal Arterial 3700 55 974 99 100 0.369 12 2

Freeway 4100 65 975 101 102 0.18 12 2

Freeway 4100 65 976 103 104 0.254 12 2

Freeway 4100 65 977 105 98 0.294 12 2

Freeway 4100 65 978 104 106 0.199 12 2

Freeway 4100 65 979 106 107 0.333 12 2

Freeway 4100 65 980 100 108 0.165 12 2

Freeway 4100 65 981 ill 173 0.819 12 2

Freeway 4100 65 982 114 113 0.902 12 2

Freeway 4100 65 983 118 117 1.749 12 2

Freeway 4100 65 984 119 116 1.752 12 2

Freeway 4100 65 985 122 121 0.775 12 2

Freeway 4100 65 986 130 841 0.979 12 1

Major Arterial 1300 55 987 841 130 0.979 12 1

Major Arterial 1300 55 988 134 334 1.145 12 1

Principal Arterial 1600 45 989 334 134 1.145 12 1

Principal Arterial 1600 45 990 200 139 0.463 12 1

Ramp 1500 35 991 114 141 0.41 12 1

Ramp 1500 35 992 144 394 0.604 12 1

Major Arterial 1300 55 993 394 144 0.604 12 1

Major Arterial 1300 55 994 146 194 1.996 12 1

Principal Arterial 1600 55 995 194 146 1.996 12 1

Principal Arterial 1600 55 996 120 162 0.338 12 1

Ramp 1500 35 997 172 171 0.485 12 1

Ramp 1500 35 998 177 112 0.805 12 1

Ramp 1500 35 999 179 328 0.282 12 1

Principal Arterial 1700 40 1000 328 179 0.282 12 1

Principal Arterial 1700 30 1001 180 231 0.319 12 1

Principal Arterial 1700 30 1002 231 180 0.319 12 1

Principal Arterial 1700 30 1003 156 302 2.415 12 1

Major Arterial 1300 55 1004 302 156 2.415 12 1

Major Arterial 1300 55 1005 175 176 0.627 12 1

Ramp 1500 35 1006 129 210 2.055 12 1

Principal Arterial 1600 55 1007 210 129 2.055 12 1

Principal Arterial 1600 55 Page 18 of 38 Page18 o 38Appendix C - Page 19 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Lik#

UNd

-oe Length Lane Number of Roadway Type Ratraeio Fvelow

___(mph)

Link#

UNod D-ode (mi)

Width (ft)

Lanes Satattio FlowFFS mph 1008 129 212 1.493 12 1

Major Arterial 1300 45 1009 212 129 1.493 12 1

Major Arterial 1300 45 1010 213 215 2.049 12 1

Major Arterial 1300 45 1011 215 213 2.049 12 1

Major Arterial 1300 45 1012 216 217 0.215 12 1

Principal Arterial 1600 45 1013 217 216 0.215 12 1

Principal Arterial 1600 45 1014 216 219 0.366 12 1

Principal Arterial 1600 30 1015 219 216 0.366 12 1

Principal Arterial 1600 30 1016 181 219 0.1 12 1

Principal Arterial 1600 30 1017 219 181 0.1 12 1

Principal Arterial 1600 30 1018 181 221 0.407 12 1

Principal Arterial 1600 30 1019 221 181 0.407 12 1

Principal Arterial 1600 30 1020 225 785 0.189 12 1

Major Arterial 1300 45 1021 785 225 0.189 12 1

Major Arterial 1300 45 1022 226 227 1.075 12 1

Major Arterial 1300 55 1023 227 226 1.075 12 1

Major Arterial 1300 55 1024 228 391 0.076 12 1

Major Arterial 1300 45 1025 391 228 0.076 12 1

Major Arterial 1300 45 1026 229 230 0.16 12 1

Principal Arterial 1700 30 1027 230 229 0.16 12 1

Principal Arterial 1700 30 1028 230 851 0.055 12 1

Principal Arterial 1600 30 1029 851 230 0.055 12 1

Principal Arterial 1600 30 1030 180 232 0.099 12

-1 Principal Arterial 1700 30 1031 232 180 0.099 12 1

Principal Arterial 1700 30 1032 233 234 0.437 12 1

Major Arterial 1300 30 1033 234 23 3 0.437 12 1

Major Arterial 1300 30 1034 236 237 0.755 12 1 _

Major Arterial 1300 55 1035 237 236 0.755 12 1

Major Arterial 1300 55 1036 229 248 0.185 12 1

Major Arterial 1700 30 1037 248 229 0.185 12 1

Major Arterial 1700 30 1038 253 254 0.375 12 1

Principal Arterial 1600 45 1039 254 253 0.375 12 1 _

Principal Arterial 1600 45 1040 776 777 0.232 12 1

Principal Arterial 1700 50 1041 777 776 0.232 12 1

Principal Arterial 1700 50 1042 255 257 0.37 12 1 _

Principal Arterial 1600 55 1043 257 255 0.37 12 1

Principal Arterial 1600 55 1044 364 396 4.749 12 1

Major Arterial 1300 55 1045 396 364 4.749 12 1

Major Arterial 1300 55 1046 260 769 0.347 12 1

Major Arterial 1700 55 1047 769 260 0.347 12 1

Major Arterial 1700 55 1048 185 263 0.32 12 1

Major Arterial 1700 30 1049 263 185 0.32 12 1

Major Arterial 1700 30 1050 264 406 0.378 12 1 _

Major Arterial 1700 30 1051 406 264 0.378 12 1

Major Arterial 1700 30 1052 265 765 1.751 12 1

Major Arterial 1300 50 1053 765 265 1.751 12 1

Major Arterial 1300 50 1054 270 271 0.329 12 1

Principal Arterial 1700 45 1055 271 270 0.329 12 1

Principal Arterial 1700 45 1056 185 262 0.653 12 1

Principal Arterial 1700 30 1057 262 185 0.653 12 1

Principal Arterial 1700 30 1058 185 272 0.413 12 1

Principal Arterial 1700 30 1059 272 185 0.413 12 1

Principal Arterial 1700 30 1060 276 277 1.978 12 1

Major Arterial 1300 55 1061 277 276 1.978 12 1

Major Arterial 1300 55 1062 157 278 4.265 12 1

1 Major Arterial 1300 55 1063 278 157 4.265 12 1

1 Major Arterial 1300 55--

Page 19 of 38 Page19 o 38Appendix C - Page 20 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Link #

U-Node D-Node Length Lane Number of Roadway Type Saturation Flow FFS (mph)

(m i)

Width (ft)

Lanes Rate (vehlhr) 1064 188 282 0.304 12 1

Principal Arterial 1600 45 1065 282 188 0.304 12 1

Principal Arterial 1600 45 1066 284 799 0.693 12 1

Principal Arterial 1600 50 1067 799 284 0.693 12 1

Principal Arterial 1600 50 1068 288 289 0.192 12 1

Minor Arterial 1700 35 1069 289 288 0.192 12 1

Minor Arterial 1700 35 1070 204 295 2.098 12 1

Major Arterial 1300 55 1071 295 204 2.098 12 1

Major Arterial 1300 55 1072 296 297 0.273 12 1

Major Arterial 1300 55 1073 297 296 0.273 12 1

Major Arterial 1300 55 1074 298 377 0.807 12 1

Major Arterial 1300 45 1075 377 298 0.807 12 1

Major Arterial 1300 45 1076 299 320 2.253 12 1

Major Arterial 1300 45 1077 320 299 2.253 12 1

Major Arterial 1300 45 1078 158 293 0.355 12 1

Major Arterial 1300 45 1079 293 158 0.355 12 1

Major Arterial 1300 45 1080 300 410 0.564 12 2

Principal Arterial 3320 40 1081 305 791 0.346 12 1-Major Arterial 1300 35 1082 791 305 0.346 12 1

Major Arterial 1300 35 1083 158 297 1.502 12 1

Major Arterial 1300 55 1084 297 158 1.502 12 1

Major Arterial 1300 55 1085 306 311 0.903 12 1

Major Arterial 1300 40 1086 311 306 0.903 12 1

Major Arterial 1300 40 1087 135 854 2.609 12 1

Major Arterial 1300 55 1088 854 135 2.609 12 1

Major Arterial 1300 55 1089 307 854 0.836 12 1

Major Arterial 1300 30 1090 854 307 0.836 12 1

Major Arterial 1300 30 1091 306 310 1.403 12 1

Major Arterial 1300 55 1092 310 306 1.403 12 1

Major Arterial 1300 55 1093 136 311 0.21 12 1

Major Arterial 1300 55 1094 311 136 0.21 12 1

Major Arterial 1300 55 1095 314 315 0.104 12 1

Major Arterial 1300 55 1096 315 314 0.104 12 1

Major Arterial 1300 55 1097 317 318 2.496 12 1

Principal Arterial 1600 45 1098 318 317 2.496 12 1

Principal Arterial 1600 45 1099 152 154 2.081 12 1

Principal Arterial 1600 55 1100 154 152 2.081 12 1

Principal Arterial 1600 55 1101 316 401 2.041 12 1

Major Arterial 1300 55 1102 401 316 2.041 12 1

Major Arterial 1300 55 1103 323 743 2.819 12 1

Major Arterial 1300 55 1104 743 323 2.819 12 1

Major Arterial 1300 55 1105 312 389 1.205 12 1

Major Arterial 1300 55 1106 389 312 1.205 12 1

Major Arterial 1300 55 1107 312 325 0.306 12 1

Major Arterial 1300 40 1108 325 312 0.306 12 1

Major Arterial 1300 40 1109 325 392 0.155 12 1

Major Arterial 1300 40 1110 392 325 0.155 12 1

Major Arterial 1300 40 1111 179 326 0.283 12 1

Principal Arterial 1700 40 1112 326 179 0.283 12 1

Principal Arterial 1700 40 1113 329 881 0.189 12 2

Principal Arterial 3320 40 1114 881 329 0.189 12 1

Principal Arterial 3320 40 1115 179 332 0.385 12 1

Principal Arterial 1700 35 1116 332 179 0.385 12 1

Principal Arterial 1700 35 1117 239 381 1.498 12 1

Principal Arterial 1600 45 1118 381 239 1.498 12 1

Principal Arterial 1600 45 119 335 336 0.144 12 1

Principal Arterial 1700 45 Page 20 of 38 Page20 o 38Appendix C - Page 21 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Lik#

UNd

-oe Length Lane Number of Roda ye Saturation Flow F(mh Link#

UNod D-ode (mi)

Width (ft)

Lanes Roda ye Rate (vehlhr)

S(mh 1120 336 335 0.144 12 1

Principal Arterial 1700 45 1121 339 384 0.269 12 1

Major Arterial 1700 30 1122 384 339 0.269 12 1

Major Arterial 1700 30 1123 341 342 0.219 12 1

Major Arterial 1700 45 1124 342 341 0.219 12 1

Major Arterial 1700 45 1125 134 353 1.185 12 1

Major Arterial 1300 45 1126 353 134 1.185 12 1

Major Arterial 1300 45 1127 341 357 0.335 12 1

Principal Arterial 1700 35 1128 357 341 0.335 12 1

Principal Arterial 1700 35 1129 359 360 1.184 12 1

Principal Arterial 1600 55 1130 360 359 1.184 12 1

Principal Arterial 1600 55 1131 362 642 2.078 12 1

Major Arterial 1300 55 1132 642 362 2.078 12 1

Major Arterial 1300 55 1133 135 363 3.915 12 1

Major Arterial 1300 55 1134 363 135 3.915 12 1

Major Arterial 1300 55 1135 131 363 2.158 12 1

Major Arterial 1300 55 1136 363 131 2.158 12 1

Major Arterial 1300 55 1137 132 352 5.985 12 1

Major Arterial 1300 55 1138 352 132 5.985 12 1

Major Arterial 1300 55___

1139 389 664 3.306 12 1

Major Arterial 1300 55___

1140 664 389 3.306 12 1

Major Arterial 1300 55___

1141 365 784 0.466 12 1

Major Arterial 1300 55___

1142 784 365 0.466 12 1

Major Arterial 1300 5

1143 132 353 4.682 12 1

Major Arterial 1300 55___

1144 353 132 4.682 12 1

Major Arterial 1300 5

1145 241 259 2.603 12 1

Principal Arterial 1600 5

1146 259 241 2.603 12 1

Principal Arterial 1600 55 1147 222 367 0.116 12 1

1 Major Arterial 1300 30 1148 367 222 0.116 12 1

Major Arterial 1300 30 1149 235 858 0.487 12 1-Major Arterial 1300 30 1150 858 235 0.487 12 1

Major Arterial 1300 30 1151 261 368 2.241 12 1

Major Arterial 1300 55 1152 368 261 2.241 12 1

Major Arterial 1300 55 1153 369 860 1.082 12 1

Major Arterial 1300 45 1154 860 369 1.082 12 1

Major Arterial 1300 45 1155 190 269 3.808 12 1

Principal Arterial 1600 55 1156 269 190 3.808 12 1

Principal Arterial 1600 55 1157 188 286 0.649 12 1

Principal Arterial 1600 55 1158 286 188 0.649 12 1

Principal Arterial 1600 55 1159 268 371 1.852 12 1

Major Arterial 1300 55 1160 371 268 1.852 12 1

Major Arterial 1300 55 1161 279 372 1.985 12 1

Major Arterial 1300 55 1162 372 279 1.985 12 1

Major Arterial 1300 55 1163 373 374 1.712 12 1

Major Arterial 1300 55 1164 374 373 1.712 12 1

Major Arterial 1300 55 1165 374 376 4.013 12 1

Major Arterial 1300 55 1166 376 374 4.013 12 1

Major Arterial 1300 55 1167 345 346 1.6 12 1

Major Arterial 1300 55 1168 346 345 1.6 12 1

Major Arterial 1300 55 1169 224 225 1.031 12 1

Major Arterial 1300 55 1170 225 224 1.031 12 1

Major Arterial 1300 55 1171 153 782 1.958 12 1

Principal Arterial 1600 55 1172 782 153 1.958 12 1

Principal Arterial 1600 55 1173 148 382 1.947 12 1

Major Arterial 1300 55 1174 382 148 1.947 12 1

Major Arterial 1300 55 1175 295 385 4.747 12 1

Major Arterial 1300 55 Page 21 of 38 Page21 o 38Appendix C - Page 22 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Link #

U-Node D-Node Length Lane Number of Roadway Type Ratraeio Felhow FFS (mph)

________(ml)

Width (ft)

Lanes Rate________

1176 385 295 4.747 12 1

Major Arterial 1300 55 1177 316 320 2.53 12 1

Principal Arterial 1600 55 1178 320 316 2.53 12 1

Principal Arterial 1600 55 1179 294 388 1.041 1

12 1

Major Arterial 1700 30 1180 388 294 1.041 12 1

Major Arterial 1700 30 1181 223 784 0.359 12 1

Major Arterial 1300 35 1182 784 223 0.359 12 1

Major Arterial 1300 35 1183 223 785 0.488 12 1

-MajorArterial 1300 35 1184 785 223 0.488 12 1

Major Arterial 1300 35 1185 341 358 0.176 12 1

Principal Arterial 1700 35 1186 358 341 0.176 12 1

Principal Arterial 1700 35 1187 307 308 0.147 12 1

Major Arterial 1300 30 1188 308 307 0.147 12 1

Major Arterial 1300 30 1189 308 309 0.778 12 1

Major Arterial 1300 30 1190 309 308 0.778 12 1

Major Arterial 1300 30 1191 142 144 2.243 12 1

Major Arterial 1300 55 1192 144 142 2.243 12 1

Major Arterial 1300 55 1193 741 742 2.461 12 1

Collector / Local Road 800 55 1194 742 741 2.461 12 1

Collector/ Local Road 800 55 1195 348 397 1.582 12 1

Collector/ Local Road 800 55 1196 397 348 1.582 12 1

Collector/ Local Road 800 55 1197 338 398 1.536 12 1

Collector /Local Road 800 45 1198 1 398 338 1.536 12 1

Collector / Local Road 800 45 1199 314 845 0.776 12 1

Collector/ Local Road 800 45 1200 845 314 0.776 12 1

Collector / Local Road 800 45 1201 232 233 0.237 12 1

Principal Arterial 1700 35 1202 233 232 0.237 12 1

Principal Arterial 1700 35 1203 330 379 0.34 12 1

Principal Arterial 1700 40 1204 379 330 0.34 12 1

Principal Arterial 1700 40 1205 331 379 0.575 12 1

Principal Arterial 1600 40 1206 379 331 0.575 12 1

Principal Arterial 1600 40 1207 370 689 2.769 12 1

Collector / Local Road 800 45 1208 689 370 2.769 12 1

Collector/ Local Road 800 45 1209 409 416 0.73 12 2

Principal Arterial 3320 45 1210 416 409 0.73 12 2

Principal Arterial 3320 45 1211 268 733 1.322 12 1

Collector /Local Road 800 45 1212 733 268 1.322 10 1

Collector/ Local Road 800 35 1213 304 412 0.338 10 1

Collector/ Local Road 800 30 1214 412 304 0.338 10 1

Collector/ Local Road 800 30 1215 304 414 0.313 10 1

Collector /Local Road 800 30 1216 414 304 0.313 10 1

Collector/ Local Road 800 30 1217 413 414 0.223 10 1

Collector I Local Road 800 30 1218 414 413 0.223 10 1

Collector/ Local Road 800 30 1219 281 283 0.191 10 1

Collector/ Local Road 800 30 1220 283 281 0.191 10 1

Collector I Local Road 800 30 1221 282 415 0.192 12 1

Collector/ Local Road 1300 40 1222 415 282 0.192 12 1

Collector/ Local Road 1300 40 1223 374 738 5.619 12 1

Collector /Local Road 800 45 1224 738 374 5.619 12 1

Collector/ Local Road 800 45 1225 356 357 0.253 12 1

Principal Arterial 1700 30 1226 357 356 0.253 12 1

Principal Arterial 1700 30 1227 420 424 1.858 12 2

Freeway 4100 65 1228 424 421 0.605 12 1

Ramp 1500 35 1229 425 430 0.251 12 1

Collector / Local Road 1300 40 1230 430 425 0.251 12 1

Collector/ Local Road 1300 40 1231 434 442 0.15 12 1

Principal Arterial 17500 45 Page 22 of 38 Page22 o 38Appendix C - Page 23 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Lik#

UNd

-oe Length Lane Number of Roda ye Saturation Flow F(mh Link#

UNod D-ode (mi)

Width (ft)

Lanes Roda ye Rate (veh/hr)FS(mh 1232 442 434 0.15 12 1

Principal Arterial 1700 45 1233 419 449 0.518 12 1

Major Arterial 1700 45 1234 447 425 0.421 12 1

-Major Arterial 1700 45.

1235 447 453 0.12 12 1

Collector/ Local Road 1700 40 1236 453 447 0.12 12 1

Collector / Local Road 1700 40 1237 442 451 0.152 12 1

Principal Arterial 1700 30 1238 451 442 0.152 12 1

Principal Arterial 1700 30 1239 461 443 0.263 12 1

Principal Arterial 1700 45 1240 449 462 0.149 12 1

Principal Arterial 1700 45 1241 459 820 0.16 12 1

Collector/ Local Road 1700 40 1242 451 463 0.139 12 1

Principal Arterial 1700 45 1243 463 451 0.139 12 1

Principal Arterial 1700 45 1244 453 464 0.148 12 1

Major Arterial 1700 45 1245 464 453 0.148 12 1

Major Arterial 1700 45 1246 467 457 0.27 12 1

Principal Arterial 1600 45 1247 462 468 0.138 12 1

Principal Arterial 1700 45 1248 463 468 0.224 12 1

Principal Arterial 1700 45 1249 471 461 0.186 12 1

Principal Arterial 1700 45 1250 468 470 0.115 12 1

Principal Arterial 1700 45 1251 468 473 0.151 12 1

Minor Arterial 1700 35 1252 469 476 0.156 12 1

Principal Arterial 1700 45 1253 844 472 0.12 12 1

Principal Arterial 1600 45 1254 489 459 0.333 12 1

Collector / Local Road 1700 40 1255 480 471 0.155 12 1

Principal Arterial 1700 45 1256 481 475 0.089 12 1

Principal Arterial 1700 45 1257 436 486 0.768 12 1

Collector / Local Road 1700 40 1258 486 436 0.768 12 1

Collector/ Local Road 1700 40 1259 472 482 0.217 12 1

Principal Arterial 1700 45 1260 490 488 0.363 12 1

Principal Arterial 1700 45 1261 479 489 1.126 12 1

Principal Arterial 1700 45 1262 489 479 1.126 12 1

Principal Arterial 1700 45 1263 486 496 0.533 10 1

Collector / Local Road 800 35 1264 496 486 0.533 10 1

Collector/ Local Road 800 35 1265 496 848 0.983 12 1

Major Arterial 1700 45 1266 848 496 0.983 12 1

Major Arterial 1700 45 1267 486 499 0.234 10 1

Collector/ Local Road 1700 35 1268 499 486 0.234 12 1

Collectorl/Local Road 1700 35 1269 488 497 0.48 12 1

Collector / Local Road 1700 40 1270 497 488 0.48 12 1

Collector/ Local Road 1700 40 1271 496 499 0.511 12 1

Major Arterial

___1700 45 1272 499 496 0.511 12 1

Major Arterial 1700 45 1273 500 839 0.186 12 1

Principal Arterial 1700 30 1274 839 500 0.186 12 1

Principal Arterial 1700 30 1275 499 809 0.244 12 1

Minor Arterial 1700 40 1276 809 499 0.244 12 1

Minor Arterial 1700 40 1277 490 501 0.293 12 2

Principal Arterial 2800 30 1278 501 490 0.293 12 2

Principal Arterial 2800 30 1279 474 520 0.95 12 1

Collector/ Local Road 1700 40 1280 520 474 0.95 12 1

Collector / Local Road 1700 40 1281 479 506 0.463 12 1

Collector/ Local Road 1700 40 1282 506 479 0.463 12 1

Collector/ Local Road 1700 40 1283 500 809 0.562 12 1

Collector / Local Road 1700 40 1284 809 500 0.562 12 1

Collector / Local Road 1700 40 1285 501 502 0.196 12 1

Collector /Local Road 1700 40 1286 502 501 0.196 12 1

Collector /Local Road 1700 40 1287 500 503 0.291 12 1

Collector/ Local Road 1700 40 Page 23 of 38 Page23 o 38Appendix C - Page 24 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Link #

U-Node D-Node (L)e Wdththt LanesNme f

RawyTp Saturation Flow FFS (mph)

Lengt Laneh NumbLaersf RawyTp Rate (vehlhr) 1288 503 500 0.291 12 1

Collector / Local Road 1700 40 1289 502 503 0.219 12 1

Collector /Local Road 1300 40 1290 503 502 0.219 12 1

Collector /Local Road 1300 40 1291 498 763 0.197 12 1

Collector /Local Road 1700 30 1292 763 498 0.197 12 1

Collector / Local Road 1700 30 1293 497 506 0.772 12 1

Collector / Local Road 1700 40 1294 506 497 0.772 12 1

Collector/ Local Road 1700 40 1295 500 511 0.164 12 1

Principal Arterial 1700 30 1296 511 500 0.164 12 1

Principal Arterial 1700 30 1297 499 515 0.272 12 1

Collector /Local Road 1700 35 1298 515 499 0.272 12 1

Collector /Local Road 1700 35 1299 508 509 0.5 12 1

Major Arterial 1700 35 1300 509 508 0.5 12 1

Major Arterial 1700 35 1301 509 510 0.25 12 1

Major Arterial 1300 35 1302 510 509 0.25 12 1

Major Arterial 1300 35 1303 512 515 0.204 12 1

Collector /Local Road 1700 35 1304 515 512 0.204 12 1

Collector/ Local Road 1700 35 1305 501 516 0.351 12 2

Principal Arterial 2800 30 1306 516 501 0.351 12 2

Principal Arterial 2800 30 1307 513 519 0.338 12 1

Minor Arterial 1300 30 1308 519 513 0.338 12 1

Minor Arterial 1300 30 1309 511 521 0.407 12 1

Principal Arterial 1700 30 1310 521 511 0.407 12 1

Principal Arterial 1700 30 1311 506 523 0.537 12 1

Collector / Local Road 1700 40 1312 523 506 0.537 12 1

Collector / Local Road 1700 40 1313 497 525 0.783 12 1

Collector / Local Road 1700 40 1314 525 497 0.783 12 1

Collector / Local Road 1700 40 1315 506 517 1.553 12 1

Collector/ Local Road 1700 40 1316 517 506 1.553 12 1

Collector/ Local Road 1700 40 1317 525 801 0.655 12 1

Collector/ Local Road 1700 40 1318 801 525 0.655 12 1

Collector/ Local Road 1700 40 1319 521 530 0.207 12 2

Principal Arterial 2800 30 1320 530 521 0.207 12 2

Principal Arterial 2800 30 1321 528 675 0.681 12 1

Collector / Local Road 1700 40 1322 675 528 0.681 12 1

Collector / Local Road 1700 40 1323 529 533 0.288 12 2

Freeway 4100 65 1324 539 538 0.495 12 1

Ramp 1500 55 1325 530 540 0.407 12 2

Principal Arterial 2800 30 1326 540 530 0.407 12 2

Principal Arterial 2800 30 1327 518 550 0.759 12 1

Major Arterial 1700 45 1328 550 518 0.759 12 1

Major Arterial 1700 45 1329 544 553 0.564 12 2

Freeway 4100 65 1330 577 817 3.65 12 1

Major Arterial 1300 55 1331 817 577 3.65 12 1

Major Arterial 1300 55 1332 542 546 0.446 12 1

Major Arterial 1300 45 1333 546 542 0.446 12 1

Major Arterial 1300 45 1334 541 790 0.416 12 1

Collector /Local Road 1700 40 1335 790 541 0.416 12 1

Collector / Local Road 1700 40 1336 554 551 0.309 12 1

Minor Arterial 1700 40 1337 552 543 0.557 12 2

Freeway 4100 65 1338 525 566 1.007 12 1

Collector/ Local Road 1700 40 1339 566 525 1.007 12 1

Collector/ Local Road 1700 40 1340 532 568 0.918 12 2

Principal Arterial 2800 35 1341 568 532 0.918 12 2

Principal Arterial 2800 35 1342 562 556 0.452 12 1

Ramp 1500 35 1343 562 560 0.369 12 1

Principal Arterial 1700 45 Page 24 of 38 Page24 o 38Appendix C - Page 25 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Link #

U-Node D-Node Length Lane Number of Roadway Type Saturation Flow FFS (mph)

_______(mi)

Width (ft)

Lanes Rate (vehlhr) 1344 526 563 0.942 12 1

Minor Arterial 1700 40 1345 563 526 0.942 12 1

Minor Arterial 1700 40 1346 557 790 1.029 12 1

Major Arterial 1700 45 1347 790 557 1.029 12 1

Major Arterial 1700 45 1348 564 572 0.213 12 2

Principal Arterial 3320 45 1349 572 564 0.213 12 2

Principal Arterial 3320 45 1350 566 568 0.746 12 2

Principal Arterial 2800 35 1351 568 566 0.746 12 2

Principal Arterial 2800 35 1352 569 572 0.452 12 2

Minor Arterial 2600 50 1353 572 569 0.452 12 2

Minor Arterial 2600 50 1354 563 565 1.464 12 1

Minor Arterial 1700 40 1355 565 563 1.464 12 1

Minor Arterial 1700 40 1356 568 569 0.678 12 2

Minor Arterial 3400 50 1357 569 568 0.678 12 2

Minor Arterial 3400 50 1358 563 579 0.744 12 1

Minor Arterial 1700 40 1359 579 563 0.744 12 1

Minor Arterial 1700 40 1360 580 834 0.607 12 1

Major Arterial 1700 45 1361 834 580 0.607 12 1

Major Arterial 1700 45 1362 576 591 0.726 12 1

Ma -jor Arterial 1300 55 1363 591 576 0.726 12 1

major Arterial 1300 55 1364 580 581 0.196 12 2

Principal Arterial 3320 45 1365 581 580 0.196 12 2

Principal Arterial 3320 45 1366 583 584 1.475 12 1

Collector / Local Road 1700 40 1367 584 583 1.475 12 1

Collector / Local Road 1700 40 1368 587 588 2.408 12 1

Major Arterial 1300 50 1369 588 587 2.408 12 1

Major Arterial 1300 50 1370 557 614 1.572 12 1

Major Arterial 1700 45 1371 614 557 1.572 12 1

Major Arterial 1700 45 1372 583 592 0.487 12 2

Minor Arterial 3400 40 1373 592 583 0.487 12 2

Minor Arterial 3400 40 1374 582 593 0.433 12 2

Principal Arterial 3320 45 1375 593 582 0.433 12 2

Principal Arterial 3320 45 1376 586 746 0.269 12 1

Minor Arterial 170Q 40 1377 746 586 0.269 12 1

Minor Arterial 1700 40 1378 598 613 0.435 12 2

Freeway 4100 65 1379 598 612 0.694 12 1

Ramp 1500 35 1380 614 618 0.992 12 1

Collector/ Local Road 1700 40 1381 618 614 0.992 12 1

Collector/ Local Road 1700 40 1382 633 746 0.487 12 1

Collector/I Local Road 1700 40 1383 746 633 0.487 12 1

Collector/ Local Road 1700 40 1384 804 631 0.532 12 2

Principal Arterial 3700 50 1385 587 640 1.356 12 1

Minor Arterial 1300 50 1386 640 587 1.356 12 1

Minor Arterial 1300 50 1387 623 642 2.112 12 1

Major Arterial 1300 45 1388 642 623 2.112 12 1

Major Arterial 1300 45 1389 636 643 0.381 12 1

Collector/ Local Road 1700 40 1390 643 636 0.3131 12 1

Collector I Local Road 1700 40 1391 638 639 0.677 12 1

Collector /Local Road 1700 45 1392 639 638 0.677 12 1

Collector / Local Road 1700 45

.1393 591 657 3.666 12 1

Major Arterial 1300 55 1394 657 591 3.666 12 1

Major Arterial 1300 55 1395 647 837 0.52 12 2

Minor Arterial 2600 40 1396 837 647 0.52 12 2

Minor Arterial 2600 40 1397 637 650 1.373 12 1

Collector /Local Road 1700 40 1398 650 637 1.373 12 1

Collector / Local Road 1700 40 1399 684 831 1.04 12 1

Minor Arterial 1700 45 Page 25 of 38 Page25 o 38Appendix C - Page 26 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Link #

U-Node D-Node Length Lane Number of Roadway Type Saturation Flow FFS (mph)

S (mi)

Width (ft)

Lanes Rate (vehlhr) 1400 831 684 1.04 12 1

Minor Arterial 1700 45 1401 649 831 0.632 12 1

Minor Arterial 1700 45 1402 831 649 0.632 12 1

Minor Arterial 1700 45 1403 640 654 1.365 12 1

Minor Arterial 1300 50 1404 654 640 1.365 12 1

Minor Arterial 1300 50 1405 651 653 0.248 12 2

Principal Arterial 3320 45 1406 653 651 0.248 12 2

Principal Arterial 3320 45 1407 649 650 1.24 12 1

Minor Arterial 1700 45 1408 650 649 1.24 12 1

Minor Arterial 1700 45 1409 652 658 1.13 10 1

Collector/ Local Road 800 35 1410 658 652 1.13 10 1

Collector/ Local Road 800 35 1411 655 657 1.662 12 1

Principal Arterial 1600 45 1412 657 655 1.662 12 1

Principal Arterial 1600 45 1413 656 788 1.285 12 1

Major Arterial 1300 55 1414 788 656 1.285 12 1

Major Arterial 1300 55 1415 658 676 2.726 12 1

Collector/ Local Road 800 45 1416 676 658 2.726 12 1

Collector/ Local Road 800 45 1417 662 720 0.698 12 2

Principal Arterial 3700 55 1418 720 661 0.696 12 2

Principal Arterial 3700 55 1419 669 670 1.13 12 1

Major Arterial 1300 45 1420 670 669 1.13 12 1

Major Arterial 1300 45 1421 671 674 1.074 12 1

Major Arterial 1300 55 1422 674 671 1.074 12 1

Major Arterial 1300 55 1423 670 841 5.014 12 1

Collector/ Local Road 800 45 1424 841 670 5.014 12 1

Collector/ Local Road 800 45 1425 512 675 0.693 12 1

Collector / Local Road 1700 30 1426 675 512 0.693 12 1

Collector /Local Road 1700 30 1427 670 947 0.826 12 1

Collector / Local Road 800 45 1428 947 670 0.826 12 1

Collector / Local Road 800 45 1429 564 679 0.208 12 1

Minor Arterial 1700 45 1430 679 564 0.208 12 1

Minor Arterial 1700 45 1431 505 574 2.002 12 1

Collector/ Local Road 800 45 1432 574 505 2.002 12 1

Collector/ Local Road 800 45 1433 567 576 1.412 12 1

Major Arterial 1300 50 1434 576 567 1.412 12 1

Major Arterial 1300 50 1435 588 591 0.934 12 1

Major Arterial 1300 50 1436 591 588 0.934 12 1

Major Arterial 1300 50 1437 527 532 0.09 12 2

Principal Arterial 2800 35 1438 532 527 0.09 12 2

Principal Arterial 2800 35 1439 514 528 0.369 12 1

Collector/ Local Road 1700 40 1440 528 514 0.369 12 1

Collector/ Local Road 1700 40 1441 643 649 0.75 12 1

Collector / Local Road 1700 40 1442 649 643 0.75 12 1

Collector / Local Road 1700 40 1443 520 541 0.594 12 1

Collector /Local Road 1700 40 1444 541 520 0.594 12 1

Collector/ Local Road 1700 40 1445 456 682 0.843 12 1

Principal Arterial 1700 45 1446 682 456 0.843 12 1

Principal Arterial 1700 45 1447 574 575 6.479 12 1

Major Arterial 1300 55 1448 575 574 6.479 12 1Major Arterial 1300 55 1449 731 688 1.266 12 1

Ramp 1500 55 1450 208 690 1.534 12 2

Principal Arterial 2800 30 1451 690 208 1.534 12 2

Principal Arterial 2800 30 1452 694 695 0.206 12 1

Minor Arterial 1700 35 1453 695 694 0.206 12 1

Minor Arterial 1700 35 1454 178 825 0.266 12 1

Major Arterial 1300 45 1455 825 178 0.266 12 1

Major Arterial 1300 45 Page 26 of 38 Page26 o 38Appendix C - Page 27 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Lik#

UNd

-oe Length Lane Number of Roda ye Saturation Flow F(mh Link#

UNod 0-ode (ml)

Width (ft)

Lanes Roda ye Rate (vehlhr)

FF(mh 1456 695 700 0.432 12 1

Minor Arterial 1300 35 1457 700 695 0.432 12 1

Minor Arterial 1300 35 1458 753 867 0.893 12 1

Major Arterial 1300 55 1459 867 753 0.893 12 1

Major Arterial 1300 55 1460 209 705 1.02 12 2

Principal Arterial 2800 30 1461 705 209 1.02 12 2

Principal Arterial 2800 30 1462 707 759 1.645 12 1

Major Arterial 1300 55 1463 759 707 1.645 12 1

Major Arterial 1300 55 1464 209 709 0.64 12 2

Principal Arterial 2800 30 1465 709 209 0.64 12 2

Principal Arterial 2800 30 1466 711 875 1.623 12 1

Major Arterial 1300 55 1467 875 711 1.623 12 1

Major Arterial 1300 55 1468 712 737 0.749 12 1

Principal Arterial 1700 30 1469 737 712 0.749 12 1

Principal Arterial 1700 30 1470 705 712 1.459 12 1

Principal Arterial 1700 30 1471 712 705 1.459 12 1

Principal Arterial 1700 30 1472 716 751 0.192 12 1

Principal Arterial 1600 45 1473 751 716 0.192 12 1

Principal Arterial 1600 45 1474 195 174 0.153 12 2

Principal Arterial 3320 45 1475 174 187 0.174 12 2

Principal Arterial 3320 45 1476 866 867 2.628 12 1

Major Arterial 1300 55 1477 867 866 2.628 12 1

Major Arterial 1300 55 1478 350 354 4.989 12 1

Major Arterial 1300 55 1479 354 350 4.989 12 1

Major Arterial 1300 55 1480 720 745 0.441 12 2

Principal Arterial 3320 40 1481 745 720 0.441 12 2

Principal Arterial 3320 40 1482 662 721 0.895 12 1

Major Arterial 1300 55 1483 721 662 0.895 12 1

Major Arterial 1300 55 1484 693 808 0.522 12 1

Minor Arterial 1700 35 1485 808 693 0.522 12 1

Minor Arterial 1700 35 1486 701 724 0.992 12 1

Minor Arterial 1300 40 1487 724 701 0.992 12 1

Minor Arterial 1300 40 1488 211 214 5.967 12 1

Collector/ Local Road 800 55 1489 214 211 5.967 12 1

Collector/ Local Road 800 55 149 0 735 751 0.188 12 2

Principal Arterial 2800 35 1491 751 735 0.188 12 2

Principal Arterial 2800 35 1492 710 738 4.694 12 1

Collector / Local Road 800 45 1493 738 710 4.694 12 1

Collector / Local Road 800 45 1494 182 124 29.133 12 2

Principal Arterial 3700 65 1495 423 505 1.251 12 1

Collector/ Local Road 800 50 1496 505 423 1.251 12 1

Collector/ Local Road 800 50 1497 491 485 0.585 12 2

Freeway 4100 65 1498 628 622 0.279 12 2

Freeway 4100 65 1499 621 630 0.249 12 2

Freeway 4100 65 1500 608 609 0.26 12 2

Freeway 4100 65 1501 622 621 0.067 12 2

Freeway 4100 65 1502 630 626 1.306 12

-2 Freeway 4100 65 1503 605 608 1.323 12 2

Freeway 4100 65 1504 626 617 0.295 12 2

Freeway 4100 65 1505 602 603 0.071 12 2

Freeway 4100 65 1506 625 804 0.261 12 2

Principal Arterial 3700 50 1507 595 596 0.436 12 2

Freeway 4100 65 1508 613 597 0.175 12 2

Freeway 4100 65 1509 688 595 0.731 12 2

Freeway 4100 65 1510 597 734 0.991 12 2

Freeway 4100 65 11511 548 1

559 0.288 12 2

Freeway 4100 65 1

Page 27 of 38 Page27 o 38Appendix C - Page 28 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Lik#

UNd

-oe Length Lane Number of Roda ye Saturation Flow F(mh Link#

UNod D-ode (mi)

Width (ft)

Lanes Roda ye Rate (vehlhr)

FF(mh 1512 673 666 2.239 12 2

Freeway 4100 65 1513 668 672 2.285 12 2

Freeway 4100 65 1514 537 830 0.848 12 2

Freeway 4100 65 1515 539 535 0.233 12 2

Freeway 4100 65 1516 533 537 0.316 12 2

Freeway 4100 65 1517 535 524 0.425 12 2

Freeway 4100 65 1518 428 732 0.358 12 2

Freeway 4100 65 1519 439 438 0.502 12 2

Freeway 4100 65 1520 842 428 0.275 12 2

Freeway 4100 65 1521 733 771 2.542 12 1

Principal Arterial 1600 55 1522 771 733 2.542 12 1

Principal Arterial 1600 55 1523 686 688 0.655 12 2

Freeway 4100 65 1524 203 702 0.283 12 1

Major Arterial 1300 45 1525 702 203 0.283 12 1

Major Arterial 1300 45 1526 726 748 0.522 12 1

Principal Arterial 1600 45 1527 748 726 0.522 12 1

Principal Arterial 1600 45 1528 167 791 0.297 12 1

Major Arterial 1300 45 1529 1 791 167 0.297 12 1

1 Major Arterial 1300 45 1530 304 305 0.465 12 1

Major Arterial 1700 35 1531 305 304 0.465 12 1

Major Arterial 1700 35 1532 237 256 1.83 12 1

Collector / Local Road 800 45 1533 256 237 1.83 12 1

Collector /Local Road 800 45 1534 347 378 2.585 12 1

Major Arterial 1300 55 1535 378 347 2.585 12 1

Mal'or Arterial 1300 55 1536 211 701 4.244 12 1

Major Arterial 1300 55 1537 701 211 4.244 12 1

Major Arterial 1300 55 1538 716 748 0.266 12 1

Principal Arterial 1700 45 1539 748 716 0.266 12 1

Principal Arterial 1700 45 1540 1 750 754 0.293 12 1

1 Major Arterial 1300 55 1541 754 750 0.293 12 1

Major Arterial 1300 55 1542 702 753 0.941 12 1

Major Arterial 1300 35 1543 753 702 0.941 12 1

Major Arterial 1300 35 1544 755 838 0.406 12 1

Major Arterial 1300 30 1545 838 755 0.406 12 1

Major Arterial 1300 30 1546 575 578 1.99 12 1

Major Arterial 1300 45 1547 578 575 1.99 12 1

Major Arterial 1300 45 1548 642 645 1.949 12 1

Major Arterial 1300 55 1549 645 642 1.949 12 1

Major Arterial 1300 55 1550 478 498 0.251 12 1

Collector /Local Road 1700 30 1551 498 478 0.251 12 1

Collector / Local Road 1700 30 1552 478 827 0.252 12 1

Collector /Local Road 1700 35 1553 827 478 0.252 12 1

Collector/ Local Road 1700 35 1554 761 760 1.101 12 2

Principal Arterial 3320 45 1555 758 764 1.218 12 2

Principal Arterial 3320 45 1556 760 758 0.118 12 2

Principal Arterial 3320 45 1557 214 744 2.939 12 1

Major Arterial 1300 5

1558 744 214 2.939 12 1

Major Arterial 1300 5

1559 222 744 1.905 12 1

Major Arterial 1300 55____

1560 744 222 1.905 12 1

Major Arterial 1300 55 ___

1561 267 276 2.78 12 1

Major Arterial 1300 45___

1562 276 267 2.78 12 1

Major Arterial 1300 45___

1563 157 265 2.314 12 1

Major Arterial 1300 55___

1564 265 157 2.314 12 1

Major Arterial 1300 55___

1565 157 266 1.306 12 1

Major Arterial 1300 55 1566 266 157 1.306 12 1

Major Arterial 1300 55 1567 249 766 0.907 12 1

Major Arterial 1300 55 Page 28 of 38 Appendix C - Page 29 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Lik#

UNd

-oe Length Lane Number of Roda ye Saturation Flow F(mh Link#

UNod D-ode (ml)

Width (ft)

Lanes Roda ye Rate (vehlhr)FF(mh 1568 766 249 0.907 12 1

Major Arterial 1300 55 1569 243 244 1.003 12 1

Major Arterial 1300 55 1570 244 243 1.003 12 1

-Major Arterial 1300 55 1571 157 242 3.104 12 1

Major Arterial 1300 55 1572 242 157 3.104 12 1

Major Arterial 1300 55 1573 245 766 0.843 12 1

Major Arterial 1300 55 1574 766 245 0.843 12 1

Major Arterial 1300 55 1575 246 250 0.882 12 1

Major Arterial 1300 55 1576 250 246 0U82 12 1

Major Arterial 1300 55 1577 247 248 0.309 12 1

Major Arterial 1700 30 1578 248 247 0.309 12 1

Major Arterial 1700 30 1579 215 218 0.381 12 1

Major Arterial 1300 45 1580 218 215 0.381 12 1

Major Arterial 1300 45 1581 133 220 4.466 12 1

Major Arterial 1300 55 1582 220 133 4.466 12 1

Major Arterial 1300 55 1583 145 228 1.976 12 1

Principal Arterial 1600 55 1584 228 145 1.976 12 1

Principal Arterial 1600 55 1585 229 231 0.305 12 1

Principal Arterial 1700 30 1586 231 229 0.305 12 1

Principal Arterial

___1700 30 1587 372 770 1.149 12 1

Major Arterial 1300 55 1588 770 372 1.149 12 1-Major Arterial 1300 55 1589 268 277 4.197 12 1

Major Arterial 1300 55 1590 277 268 4.197 12 1

Major Arterial 1300 45 1591 280 371 0.675 12 1

Major Arterial 1300 40 1592 371 280 0.675 12 1

Major Arterial 1300 40 1593 281 415 0.088 12 1

Major Arterial 1300 45 1594 415 281 0.088 12 1

Major Arterial 1300 45 1595 403 777 0.301 12 1

Principal Arterial 1700 45 1596 777 403 0.301 12 1

Principal Arterial 1700 45 1597 403 798 0.199 12 1

Principal Arterial 1700 35 1598 798 403 0.199 12 1

Principal Arterial 1700 35 1599 376 778 2.894 12 1

Major Arterial 1300 55 1600 778 376 2.894 12 1

Major Arterial 1300 55 1601 261 287 1.611 12 1

Minor Arterial 1300 55 1602 287 261 1.611 12 1

Minor Arterial 1300 55 1603 287 290 1.555 12 1

Minor Arterial 1300 55 1604 290 287 1.555 12 1

Minor Arterial 1300 55 1605 289 800 0.111 12 1

Principal Arterial 1700 55 1606 800 289 0.111 12 1

Principal Arterial 1700 55 1607 320 417 3.411 12 1

Principal Arterial 1600 55 1608 417 320 3.411 _

12 1

Principal Arterial 1600 55 1609 385 780 4.704 12 1

Major Arterial 1300 55 1610 780 385 4.704 12 1

Major Arterial 1300 55 1611 781 846 0.172 12 1

Major Arterial 1700 45 1612 846 781 0.172 12 1

Major Arterial 1700 45 1613 186 411 0.642 12 1

Major Arterial 1700 45 1614 411 186 0.642 12 1

Major Arterial 1700 45 1615 144 743 0.392 12 1

Major Arterial 1300 55 1616 743 144 0.392 12 1

Major Arterial 1300 55 1617 227 354 5.982 12 1

Major Arterial 1300 55 1618 354 227 5.982 12 1

Major Arterial 1300 55 1619 223 226 0.516 12 1

Major Arterial 1300 45 1620 226 223 0.516 12 1

Major Arterial 1300 45 1621 238 239 0.847 12 1

Major Arterial 1300 45 1622 239 238 0.847 12 1

Major Arterial 1300 45 1623 661 783 1.149 122 Principal Arterial 3700 55 Page 29 of 38 Page29 o 38Appendix C - Page 30 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Lik#

UNd

-oe Length Lane Number of Roadway Type Ratraeio Felhow

____(mph)

Lik -Nde DNoe (ml)

Width (ft)

Lanes FFte (mph)h 1624 315 786 1.565 12 1

Major Arterial 1300 55 1625 786 315 1.565 12 1

Major Arterial 1300 55 1626 667 721 1.83 12 1

Major Arterial 1300 55 1627 721 667 1.83 12 1

Major Arterial 1300 55 1628 664 665 1.542 12 1

Major Arterial 1300 55 1629 665 664 1.542 12 1

Major Arterial 1300 55 1630 314 383 3.558 12 1

Major Arterial 1300 45 1631 383 314 3.558 12 1

Major Arterial 1300 45 1632 324 740 1.535 12 1

Malor Arterial 1300 55 1633 740 324 1.535 12 1

Major Arterial 1300 55 1634 324 787 0.539 12 1

Major Arterial 1300 40 1635 787 324 0.539 12 1

Major Arterial 1300 40 1636 654 655 0.982 12 1

Principal Arterial 1600 55 1637 1 655 654 0.982 12 1

1 Principal Arterial 1600 55 1638 654 945 1.866 12 1

Principal Arterial 1600 55 1639 945 654 1.866 12 1

Principal Arterial 1600 55 1640 584 637 1.172 12 1

Collector / Local Road 1700 40 1641 637 584 1.172 12 1

Collector /Local Road 1700 40 1642 161 775 0.461 12 1

Principal Arterial 1600 45 1643 775 159 0.46 12 1

Principal Arterial 1600 45 1644 523 565 1.011 12 1

Collector/ Local Road 1700 40 1645 565 523 1.011 12 1

Collector /Local Road 1700 40 1646 639 652 2.952 12 1

Collector / Local Road 1700 45 1647 652 639 2.952 12 1

Collector / Local Road 1700 45 1648 309 310 1.688 12 1

Major Arterial 1300 55 1649 310 309 1.688 12 1

Major Arterial 1300 55 1650 136 144 1

12 1

Major Arterial 1300 55 1651 144 136 1

12 1

Major Arterial 1300 55 1652 584 585 0.847 12 1

Collector/ Local Road 1700 40 1653 585 584 0.847 12 1

Collector / Local Road 1700 40 1654 338 390 2.303 12 1

Major Arterial 1300 55 1655 390 338 2.303 12 1

Major Arterial 1300 55 1656 355 356 0.628 12 1

Principal Arterial 1700 30 1657 356 355 0.628 12 1

Principal Arterial 1700 30 1658 307 386 0.567 12 1

Major Arterial 1300 45 1659 386 307 0.567 12 1

Major Arterial 1300 45 1660 206 303 0.515 12 1

Major Arterial 1300 40 1661 303 206 0.515 1

12 1

Major Arterial 1300 40 1662 289 333 0.262 12 1

Collector / Local Road 1700 35 1663 333 289 0.262 12 1

Collector/ Local Road 1700 35 1664 518 520 1.004 12 1

Major Arterial 1700 45 1665 520 518 1.004 12 1

Major Arterial 1700 45 1666 179 336 1.282 12 1

Principal Arterial 1700 30 1667 336 179 1.282 12 1

Principal Arterial 1700 30 1668 335 399 0.516 12 1

Principal Arterial 1600 45 1669 399 335 0.516 12 1

Principal Arterial 1600 45 1670 178 698 1.994 12 1

Major Arterial 1300 55 1671 698 178 1.994 12 1

Major Arterial 1300 55 1672 528 530 0.603 12 1

Collector / Local Road 1700 40 1673 530 528 0.603 12 1

Collector/ Local Road 1700 40 1674 526 541 1.634 12 1

Major Arterial 1700 45 1675 541 526 1.634 12 1

Major Arterial 1700 45 1676 565 566 0.75 12 1

Minor Arterial 1700 40 1677 566 565 0.75 12 1

Minor Arterial 1700 40 1678 566 585 1.178 12 1

Major Arterial 1700 35 1679 585 566 1.178 12 1

Major Arterial 1700 35 Page 30 of 38 Page30 o 38Appendix C - Page 31 of 44

Appendix C Byron INGS Appenix CByro NGSRoadway Network Data Table Lik#

UNd

-oe Length Lane Number of Roda ye Saturation Flow F(mh Link#

UNod D-ode (ml)

Width (ft)

Lanes Roda ye Rate (vehlhr) 1680 474 492 1.526 12 1

Principal Arterial 1700 45 1681 492 474 1.526 12 1

Principal Arterial 1700 45 1682 699 700 0.561 12 2

-Minor Arterial 2600 40 1683 700 699 0.561 12 2

Minor Arterial 2600 40 1684 797 822 0.562 12 2

Principal Arterial 3320 40 1685 700 807 0.135 12 1

Major Arterial 1300 45 1686 807 700 0.135 12 1

Major Arterial 1300 45 1687 582 587 1.859 12 1

Major Arterial 1300 45 1688 587 582 1.859 12 1

Major Arterial 1300 45 1689 572 582 1.015 12 2

Principal Arterial 3320 45 1690 582 572 1.015 12 2

Principal Arterial 3320 45 1691 511 515 0.783 12 1

Collector/ Local Road 1700 35 1692 515 511 0.783 12 1

Collector / Local Road 1700 35 1693 551 816 0.304 12 1

Minor Arterial 1700 40 1694 436 442 0.727 12 1

Principal Arterial 1700 30 1695 442 436 0.727 12 1

Principal Arterial 1700 30 1696 815 810 0.269 12 1

Principal Arterial 1700 45 1697 538 549 0.147 12 1

Freeway 2050 55 1698 422 418 2.064 12 2

Freeway 4100 65 1699 465 475 0.287 12 1

Collector / Local Road 1700 40 1700 476 482 0.072 12 1

Principal Arterial 1700 45 1701 819 871 0.975 12 1

Major Arterial 1300 55 1702 871 819 0.975 12 1

Major Arterial 1300 55 1703 380 689 2.248 12 1

Collector/ Local Road 800 45 1704 689 380 2.248 12 1

Collector/ Local Road 800 45 1705 169 101 0.437 12 2

Freeway 4100 65 1706 687 805 1.085 12 2

Freeway 4100 65 1707 731 734 1.112 12 2

Freeway 4100 65 1708 128 698 2.31 12 1

Major Arterial 1300 55 1709 698 128 2.31 12 1

Major Arterial 1300 55 1710 694 808 0.206 12 1

Minor Arterial 1300 35 1711 808 694 0.206 12 1

Minor Arterial 1300 35 1712 208 693 0.87 12 2

Minor Arterial 3400 35 1713 693 208 0.87 12 2

Minor Arterial 3400 35 1714 691 725 2.751 12 1

Principal Arterial 1600 55 1715 725 691 2.751 12 1

Principal Arterial 1600 55 1716 696 699 0.778 12 2

Principal Arterial 3320 40 1717 699 696 0.778 12 2

Principal Arterial 3320 40 1718 540 564 0.41 12 2

Principal Arterial 3320 45 1719 564 540 0.41 12 2

Principal Arterial 3320 45 1720 722 745 0.286 12 2

Principal Arterial 2800 30 1721 745 722 0.286 12 2

Principal Arterial 2800 30 1722 484 767 0.766 12 1

Major Arterial 1300 45 1723 767 484 0.766 12 1

Major Arterial 1300 45 1724 492 517 0.677 12 1

Collector/ Local Road 1700 40 1725 517 492 0.677 12 1

Collector/ Local Road 1700 40 1726 322 383 1.088 12 1

Major Arterial 1300 45 1727 383 322 1.088 12 1

Major Arterial 1300 45 1728 833 535 0.406 12 1

Ramp 1500 55 1729 536 833 0.148 12 1

Freeway 2050 55 1730 790 834 0.183 12 2

Principal Arterial 3320 45 1731 834 790 0.183 12 2

Principal Arterial 3320 45 1732 541 550 1.023 12 1

Major Arterial 1700 45 1733 550 541 1.023 12 1

Major Arterial 1700 45 1734 550 1

557 0.164 12 1

Major Arterial 1700 45 1735 557 1

550 0.164 12 1

Major Arterial 1700 45 Page 31 of 38 Appendix C - Page 32 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Lik#

UNd

-oe Length Lane Number of Roda ye Saturation Flaw F(mh Link#

UNod D-ode (ml)

Width (ft)

Lanes Roda ye Rate (vehlhr) 1736 618 684 1.561 12 1

Major Arterial 1700 45 1737 684 618 1.561 12 1

Major Arterial 1700 45 1738 664 835 1.828 12 1

-Major Arterial 1300 55 1739 835 664 1.828 12 1

Major Arterial 1300 55 1740 663 676 4.909 12 1

Major Arterial 1300 45 1741 676 663 4.909 12 1

Major Arterial 1300 45 1742 505 817 1.011 12 1

Major Arterial 1300 50 1743 817 505 1.011 12 1

Major Arterial 1300 50 1744 420 762 0.443 12 1

Minor Arterial 1300 35 1745 762 420 0.443 12 1

Minor Arterial 1300 35 1746 510 832 0.214 12 1

Major Arterial 1700 35 1747 832 510 0.214 12 1

Major Arterial 1700 35 1748 426 431 2.311 12 2

Principal Arterial 3320 45 1749 431 426 2.311 12 2

Principal Arterial 3320 45 1750 719 662 3.76 12 2

Principal Arterial 3700 55 1751 520 522 1.504 12 1

Minor Arterial 1700 40 1752 522 520 1.504 12 1

Minor Arterial 1700 40 1753 424 495 1.687 12 2

Freeway 4100 65 1754 494 544 1.922 12 2

Freeway 4100 65 1755 543 491 1.929 12 2

Freeway 4100 65 1756 651 652 0.723 12 1

Minor Arterial 1700 45 1757 652 651 0.723 12 1

Minor Arterial 1700 45 1758 650 651 0.771 12 1

Minor Arterial 1700 45 1759 651 650 0.771 12 1

Minor Arterial 1700 45 1760 637 638 1.232 12 1

Collector/ Local Road 1700 45 1761 638 637 1.232 12 1

Collector/ Local Road 1700 45 1762 633 647 2.554 12 1

Collector /Local Road 1700 35 1763 647 633 2.554 12 1

Collector /Local Road 1700 35 1764 805 668 2.933 12 2

Freeway 4100 65 1765 666 731 2.91 12 2

Freeway 4100 65 1766 734 573 2.103 12 2

Freeway 4100 65 1767 570 686 1.849 12 2

Freeway 4100 65 1768 618 624 1.823 12

-1 Major Arterial 1700 45 1769 624 618 1.823 12 1

Major Arterial 1700 45 1770 581 583 1.533 12 1

Collector /Local Road 1700 40 1771 583 581 1.533 12 1

Collector /Local Road 1700 40 1772 606 598 1.808 12 2

Freeway 4100 65 1773 596 601 1.767 12 2

Freeway 4100 65 1774 636 637 1.62 12 1

Collector / Local Road 1700 45 1775 637 636 1.62 12 1

Collector / Local Road 1700 45 1776 547 756 6.5 12 1

Major Arterial 1300 55 1777 756 547 6.5 12 1

Major Arterial 1300 55 1778 565 584 0.999 12 1

Collector / Local Road 1700 40 1779 584 565 0.999 12 1

Collector / Local Road 1700 40 1780 585 586 0.895 12 1

Collector /Local Road 1700 40 1781 586 585 0.895 12 1

Collector / Local Road 1700 40 1782 568 586 0.998 12 1

Minor Arterial 1700 40 1783 586 568 0.998 12 1

Minor Arterial 1700 40 1784 629 641 0.813 12 2

Principal Arterial 3320 45 1785 641 629 0.813 12 2

Principal Arterial 3320 45 1786 587 678 1.628 12 1

Minor Arterial 1300 45 1787 678 587 1.628 12 1

Minor Arterial 1300 45 1788 578 838 0.305 12 1

Major Arterial 1300 35 1789 838 578 0.305 12 1

Major Arterial 1300 35 1790 1

532 534 0.811 12 1

Collector/ Local Road 1700 40 1791 1

534 532 0.811 12 1

Collector / Local Road 1700 40 Page 32 of 38 Page32 o 38Appendix C - Page 33 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Lik#

UNd

-oe Length Lane Number of Roda ye Saturation Flow F(mh Link#

UNod D-ode (ml)

Width (ft)

Lanes Roda ye Rate (vehlhr)FS(mh 1792 477 470 0.164 12 2

Principal Arterial 2800 30 1793 477 839 0.239 12 2

Principal Arterial 2800 30 1794 839 477 0.239 12 2

Principal Arterial 2800 30 1795 525 527 0.758 12 1

Collector / Local Road 1700 40 1796 527 525 0.758 12 1

CollectorI Local Road 1700 40 1797 516 527 0.299 12 2

Principal Arterial 2800 35 1798 527 516 0.299 12 2

Principal Arterial 2800 35 1799 546 567 0.749 12 1

Major Arterial 1300 45 1800 567 546 0.749 12 1

Major Arterial 1300 45 1801 475 471 0.163 12 1

Principal Arterial 1700 45 1802 444 445 0.071 12 1

Collector/ Local Road 1700 40 1803 445 444 0.071 12 1

Collector /Local Road 1700 40 1804 446 469 0.364 12 1

Principal Arterial 1700 45 1805 659 671 4.005 12 1

Major Arterial 1300 55 1806 671 659 4.005 12 1

Major Arterial 1300 55 1807 563 790 1.51 12 1

Minor Arterial 1700 40 1808 790 563 1.51 12 1

Minor Arterial 1700 40 1809 449 434 0.377 12 1

Principal Arterial 1700 45_

1810 451 462 0.225 10 1

Collector! Local Road 800 30 1811 462 451 0.225 10 1

Collector/ Local Road 800 30 1812 432 436 0.936 12 1

Principal Arterial 1700 30 1813 436 432 0.936 12 1

Principal Arterial 1700 30 1814 522 523 1.462 12 1

Minor Arterial 1700 40 1815 523 522 1.462 12 1

Minor Arterial 1700 40 1816 474 682 1.016 12 1

Principal Arterial 1700 45 1817 682 474 1.016 12 1

Principal Arterial 1700 45 1818 518 682 1.085 12 1

Major Arterial 1700 45 1819 682 518 1.085 12 1

Major Arterial 1700 45 1820 732 529 1.206 12 3

Freeway 6150 65 1821 524 458 1.209 12 3

Freeway 6150 65 1822 479 492 1.485 12 1

Principal Arterial 1700 45 1823 492 479 1.485 12 1

Principal Arterial 1700 45 1824 485 422 1.468 12 2

Freeway 4100 65 1825 762 827 0.15 12 1

Collector / Local Road 1300 35 1826 827 762 0.15 12 1

Collector I Local Road 1300 35 1827 423 426 1.024 12 2

Principal Arterial 3320 45 1828 426 423 1.024 12 2

Principal Arterial 3320 45 1829 464 476 0.388 12 2

Collector / Local Road 1600 30 1830 476 464 0.388 12 2

Collector / Local Road 1600 30 1831 611 552 2.062 12 2

Freeway 4100 65 1832 553 628 2.007 12 2

Freeway 4100 65 1833 796 841 2.106 12 1

Major Arterial 1300 55 1834 841 796 2.106 12 1

Major Arterial.

1300 55 1835 322 845 1.531 12 1

Collector /Local Road 800 45 1836 845 322 1.531 12 1

Collector! Local Road 800 45 1837 301 303 0.389 12 1

Major Arterial 1700 40 1838 303 301 0.389 12 1

Major Arterial 1700 40 1839 292 385 7.359 12 1

Major Arterial 1300 55 1840 385 292 7.359 12 1

Major Arterial 1300 55 1841 340 742 0.344 12 1

Major Arterial 1300 55 1842 742 340 0.344 12 1

Major Arterial 1300 55 1843 803 848 1.107 12 1

Minor Arterial 1700 45 1844 848 803 1.107 12 1

Minor Arterial 1700 45 1845 123 109 1.742 12 2

Freeway 4100 65 1846 107 122 1.291 12 2

Freeway 4100 65 1847 121 119 5.399 12 2

Freeway 4100 65 Page 33 of 38 Page33 o 38Appendix C - Page 34 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Link #

U-Node D-Node Length Lane Number of Roadway Type Saturation Flow FF5 (mph)

S(mi)

Width (ft)

Lanes Rate (vehlhr) 1848 117 120 4.531 12 2

Freeway 4100 65 1849 672 200 3.825 12 2

Freeway 4100 65 1850 173 175 21.073 12

-2 Freeway 4100 65 1851 112 172 21.298 12 2

Freeway 4100 65 1852 165 ill 1.74 12 2

Freeway 4100 65 1853 110 169 1.664 12 2

Freeway 4100 65 1854 116 114 6.421 12 2

Freeway 4100 65 1855 115 118 6.239 12 2

Freeway 4100 65 1856 200 115 0.299 12 2

Freeway 4100 65 1857 113 673 3.913 12 2

Freeway 4100 65 1858 221 258 0.227 12 1

Principal Arterial 1600 35 1859 258 221 0.227 12 1

Principal Arterial 1600 35 1860 258 1

393 2.647 12 1

Principal Arterial 1600 55 1

1861 393 258 2.647 12 1

Principal Arterial 1600 55 1862 214 354 6.901 12 1

Major Arterial 1300 55 1863 354 214 6.901 12 1

Major Arterial 1300 55 1864 213 744 4.983 12 1

Major Arterial 1300 55 1865 744 213 4.983 12 1-Major Arterial 1300 55 1866 211 213 2.081 12 1

Major Arterial 1300 55 1867 213 211 2.081 12 1

Major Arterial 1300 55 1868 264 765 0.183 12 1

MaJor Arterial 1300 30 1869 765 264 0.183 12 1

Major Arterial 1300 30 1870 276 749 1.191 12 1

Major Arterial 1300 55 1871 749 276 1.191 12 1-Major Arterial 1300 55 1872 280 281 0.255 1

12 1

Major Arterial 1300 30 1873 281 280 0.255 12 1

-Major Arterial 1300 30 1874 189 267 2.18 12 1

Principal Arterial 1600 45 1875 267 189 2.18 12 1

Principal Arterial 1600 45 1876 233 251 0.604 12 1

Principal Arterial 1700 35 1877 251 233 0.604 12 1

Principal Arterial 1700 35 1878 327 798 0.242 12 1

Principal Arterial 1700 30 1879 798 327 0.242 12 1

Principal Arterial 1700 30 1880 340 384 0.481 12 1

Major Arterial 1300 30 1881 384 340 0.481 12 1

Major Arterial 1300 30 1882 239 399 1.185 12 1

Principal Arterial 1600 45 1883 399 239 1.185 12 1

Principal Arterial 1600 45 1884 417 847 1.762 12 1

Principal Arterial 1600 55 1885 847 417 1.762 12 1

Principal Arterial 1600 55 1886 288 290 0.255 12 1

Minor Arterial 1700 55 1887 290 288 0.255 12 1

Minor Arterial 1700 55 1888 375 852 0.62 12 1

Major Arterial 1300 55 1889 852 375 0.62 12 1

Major Arterial 1300 55 1890 285 800 2.175 12 1

Principal Arterial 1600 55 1891 800 285 2.175 12 1

Principal Arterial 1600 55 1892 285 799 1.483 12 1

Principal Arterial 1600 55 1893 799 285 1.483 12 1

Principal Arterial 1600 55 1894 135 793 1.954 12 1

Major Arterial 1300 55 1895 793 135 1.954 12 1

Major Arterial 1300 55 1896 742 855 3.063 12 1

Major Arterial 1300 55 1897 855 742 3.063 12 1

Major Arterial 1300 55 1898 348 395 1.428 12 1

Major Arterial 1300 55 1899 395 348 1.428 12 1

Major Arterial 1300 55 1900 334 381 3.939 12 1

Principal Arterial 1600 45 1901 381 334 3.939 12 1

Principal Arterial 1600 45 1902 856 857 0.092 12 1

Major Arterial 1700 45 1903 857 856 0.092 12 1

Major Arterial 1700 45 Page 34 of 38 Page34 o 38Appendix C - Page 35 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Lik#

UNd

-oe Length Lane Number of Roda ye Saturation Flow F(mh Link#

UNod 0-ode (ml)

Width (ft)

Lanes Roda ye Rate (vehlhr)FF(mh 1904 234 858 0.043 12 1

Major Arterial 1700 30 1905 858 234 0.043 12 1

Major Arterial 1700 30 1906 133 366 0.485 12 1

-Major Arterial 1300 55 1907 366 133 0.485 12 1

Major Arterial 1300 55 1908 366 367 0.523 12 1

Major Arterial 1300 30 1909 367 366 0.523 12 1

Major Arterial 1300 30 1910 133 364 5.334 12 1

Major Arterial 1300 55 1911 364 133 5.334 12 1

Major Arterial 1300 55 1912 309 313 3.157 12 1

Major Arterial 1300 55 1913 313 309 3.157 12 1

Major Arterial 1300 55 1914 740 786 0.647 12 1

Major Arterial 1300 45 1915 786 740 0.647 12 1

Major Arterial 1300 45 1916 322 394 2.007 12 1

Major Arterial 1300 55 1917 394 322 2.007 12 1

Major Arterial 1300 55 1918 158 780 1.856 12 1

Major Arterial 1300 55 1919 780 158 1.856 12 1

Major Arterial 1300 55 1920 186 409 1.072 12 1

Major Arterial 1700 35 1921 409 186 1.072 12 1

Major Arterial 1700 35 1922 413 859 0.038 12 1

Major Arterial 1300 30 1923 859 413 0.038 12 1

Major Arterial 1300 30 1924 297 859 2.167 12 1

Major Arterial 1300 55 1925 859 297 2.167 12 1

Major Arterial 1300 55 1926 192 296 1.397 12 1

Major Arterial 1300 55 1927 296 192 1.397 12 1-Major Arterial 1300 55 1928 192 780 1.857 12 1

Collector / Local Road 800 45 1929 780 192 1.857 12 1

Collector /Local Road 800 45 1930 192 295 5.17 12 1

Major Arterial 1300 55 1931 295 192 5.17 12 1

Major Arterial 1300 55 1932 162 300 1.483 12 2

Principal Arterial 3320 45 1933 822 160 2.417 12 2

Principal Arterial 3320 45 1934 304 411 0.678 12 1

Major Arterial 1700 45 1935 411 304 0.678 12 1

Major Arterial 1700 45 1936 387 408 1.57 12 1

Major Arterial 1300 45 1937 408 387 1.57 12 1

Major Arterial 1300 45 1938 337 402 2.956 12 1

Major Arterial 1300 45 1939 402 337 2.956 12 1

Major Arterial 1300 45 1940 376 377 8.021 12 1

Major Arterial 1300 55 1941 377 376 8.021 12 1

Major Arterial 1300 55 1942 374 377 5.297 12 1

Major Arterial 1300 55 1943 377 374 5.297 12 1

Major Arterial 1300 55 1944 298 375 1.07 12 1

Major Arterial 1300 45 1945 375 298 1.07 12 1

Major Arterial 1300 45 1946 137 312 1.061 12 1

Major Arterial 1300 40 1947 312 137 1.061 12 1

Major Arterial 1300 40 1948 352 646 4.543 12 1

Major Arterial 1300 55 1949 646 352 4.543 12 1

Major Arterial 1300 55 1950 240 275 0.67 12 1

Principal Arterial 1600 40 1951 275 240 0.67 12 1

Principal Arterial 1600 40 1952 284 733 2.00 1 12 1

Principal Arterial 1600 55 1953 733 284 2.001 12 1

Principal Arterial 1600 55 1954 268 279 1.576 12 1

Major Arterial 1300 55 1955 279 268 1.576 12 1

Major Arterial 1300 55 1956 358 853 0.171 12 1

Principal Arterial 1700 45 1957 853 358 0.171 12 1

Principal Arterial 1700 45 1958 344 855 2.921 12 1

Major Arterial 1300 55 1959 855 344 2.921 12 1

Major Arterial 1300 55 Page 35 of 38 Page35 o 38Appendix C - Page 36 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Link #

U-Node D-Node Length Lane Number of Roadway Type Saturation Flow FFS (mph) mi)

Width (ft)

Lanes Rate (vehlhr) 1960 400 774 0.987 12 1

Principal Arterial 1600 55 1961 774 400 0.987 12 1

Principal Arterial 1600 55 1962 194 851 5.293 12 1

Principal Arterial 1600 55 1963 851 194 5.293 12 1

Principal Arterial 1600 55 1964 342 855 0.361 12 1

Major Arterial 1300 45 1965 855 342 0.361 12 1

Major Arterial 1300 45 1966 794 855 0.461 12 1

Major Arterial 1300 55 1967 855 794 0.461 12 1

Major Arterial 1300 55 1968 757 862 1.418 12 2

Principal Arterial 3320 45 1969 862 757 1.418 12 2

Principal Arterial 3320 45 1970 735 863 0.122 12 2

Principal Arterial 2800 35 1971 863 735 0.122 12 2

Principal Arterial 2800 35 1972 706 863 0.304 12 2

Principal Arterial 2800 30 1973 863 706 0.304 12 2

Principal Arterial 2800 30 1974 706 713 0.791 12 1

Major Arterial 1700 35 1975 713 706 0.791 12 1

Major Arterial 1700 35 1976 750 864 0.211 12 1

Major Arterial 1700 55 1977 864 750 0.211 12 1

Major Arterial 1700 55 1978 376 727 8.066 12 1

Major Arterial 1300 55 1979 727 376 8.066 12 1

Major Arterial 1300 55 1980 727 868 1.902 12 1

Collector /Local Road 800 45 1981 868 727 1.902 12 1

Collector/ Local Road 800 45 1982 207 703 0.35 12 1

Major Arterial 1300 35 1983 703 207 0.35 12 1

Major Arterial 1300 1

35 1984 207 869 0.25 12 1

Major Arterial 1300 30 1985 869 207 0.25 12 1

Major Arterial 1300 30 1986 373 711 5.954 12 1

Major Arterial 1300 55 1987 711 373 5.954 12 1

Major Arterial 1300 55 1988 707 710 1.974 12 1

Major Arterial 1300 45 1989 710 707 1.974 12 1

Major Arterial 1300 45 1990 207 707 5.647 12 1

Major Arterial 1300 55 1991 707 207 5.647 12 1

Major Arterial 1300 55 1992 184 706 1.558 12 2

Principal Arterial 2800 30 1993 706 184 1.558 12 2

Principal Arterial 2800 30 1994 708 759 0.965 12 1

Major Arterial 1300 50 1995 759 708 0.965 12 1

Major Arterial 1300 50 1996 709 861 0.389 12 1

Major Arterial 1700 45 1997 861 709 0.389 12 1

Major Arterial 1700 45 1998 184 758 5.081 12 2

Principal Arterial 3320 45 1999 758 184 5.081 12 2

Principal Arterial 3320 45 2000 184 705 0.433 12 2

Principal Arterial 2800 30 2001 705 184 0.433 12 2

Principal Arterial 2800 30 2002 208 806 0.589 12 2

Principal Arterial 2800 30 2003 806 208 0.589 12 2

Principal Arterial 2800 30 2004 713 754 0.616 12 1

Major Arterial 1300 45 2005 754 713 0.616 12 1

Major Arterial 1300 45 2006 749 865 1.178 12 1

Major Arterial 1700 55 2007 865 749 1.178 12 1

Major Arterial 1700 55 2008 724 876 0.505 12 1

Major Arterial 1300 45 2009 876 724 0.505 12 1

Major Arterial 1300 45 2010 267 726 2.577 12 1

Principal Arterial 1600 55 2011 726 267 2.577 12 1

Principal Arterial 1600 55 2012 823 878 0.376 12 1

Major Arterial 1700 45 2013 878 823 0.376 12 1

Major Arterial 1700 45 2014 806 823 0.861 12 2

Principal Arterial 3320 45 2015 823 806 0.861 12 2

Principal Arterial 3320 455 Page 36 of 38 Page36 o 38Appendix C - Page 37 of 44

Appendix C Byron NGS Appenix CByro NGSRoadway Network Data Table Lik#

UNd

-oe Length Lane Number of Roda ye Saturation Flow F(mh Link#

UNod D-ode (ml)

Width (ft)

Lanes Roda ye Rate (vehlhr)FS(mh 2016 693 877 1.228 12 1

Major Arterial 1700 45 2017 877 693 1.228 12 1

Major Arterial 1700 45 2018 692 823 0.747 12 2

Principal Arterial 3320 45 2019 823 692 0.747 12 2

Principal Arterial 3320 45 2020 128 182 3.66 12 2

Principal Arterial 3700 65 2021 183 127 3.658 12 2

Principal Arterial 3700 65 2022 127 125 3.226 12 2

Principal Arterial 3700 65 2023 193 128 3.481 12 2

Principal Arterial 3700 65 2024 174 209 1.24 12 2

Principal Arterial 3320 45 2025 209 174 1.ý24 12 2

Principal Arterial 3320 45 2026 168 167 0.103 12 2

Principal Arterial 3320 45 2027 224 884 2.97 10 1

Collector I Local Road 800 15 2028 884 224 2.97 10 1

Collector! Local Road 800 15 2029 396 889 6.231 10 1

Collector/ Local Road 800 15 2030 889 396 6.231 10 1

Collector /Local Road 800 15 2031 373 894 3.687 10 1

Collector! Local Road 800 15 2032 894 373 3.687 10 1

Collector / Local Road 800 15 2033 371 897 4.818 10 1

Collector /Local Road 800 15 2034 897 371 4.818 10 1

Collector/ Local Road 800 15 2035 299 907 4.698 10 1

Collector! Local Road 800 15 2036 907 299 4.698 10 1

Collector!/ Local Road 800 15 2037 411 908 2.023 10 1

Collector /Local Road 800 15 2038 908 411 2.023 10 1

Collector! Local Road 800 15 2039 296 911 2.227 10 1

Collector!/ Local Road 800 15 2040 911 296 2.227 10 1

Collector /Local Road 800 15 2041 347 915 9.368 10 1

Collector!/ Local Road 800 15 2042 915 347 9.368 10 1

Collector! Local Road 800 15 2043 361 919 3.855 10 1

Collector /Local Road 800 15 2044 919 361 3.855 10 1

Collector! Local Road 800 15 2045 362 920 5.089 10 1

Collector! Local Road 800 15 2046 920 362 5.089 10 1

Collector!/ Local Road 800 15 2047 381 927 4.516 10 1

Collector/ Local Road 800 15 2048 927 381 4.516 10 1

Collector! Local Road 800 15 2049 136 930 2.621 10 1

Collector! Local Road 800 15 2050 930 136 2.621 10 1

Collector I Local Road 800 15 2051 315 933 2.616 10 1

Collector/ Local Road 800 15 2052 933 315 2.616 10 1

Collector! Local Road 800 15 2053 313 936 5.226 10 1

Collector!/ Local Road 800 15 2054 936 313 5.226 10 1

Collector /Local Road 800 15 2055 845 937 4.499 10 1

Collector / Local Road 800 15 2056 937 845 4.499 10 1

Collector! Local Road 800 15 2057 721 940 6.78 10 1

Collector /Local Road 800 15 2058 940 721 6.78 10 1

Collector/ILocal Road 800 15 2059 659 948 1.271 10 1

Collector! Local Road 800 15 2060 948 659 1.271 10 1

Collector! Local Road 800 15 2061 903 971 0.571 10 1

Collector /Local Road 800 15 2062 971 903 0.571 10 1

Collector! Local Road 800 15 2063 180 971 0.61 10 1

Collector / Local Road 800 15 2064 971 180 0.61 10 1

Collector /Local Road 800 15 2065 288 968 1.223 10 1

Collector! Local Road 800 15 2066 968 288 1.223 10 1

Collector /Local Road 800 15 2067 798 968 1.211 10 1

Collector/ Local Road 800 15 2068 968 798 1.211 10 1

Collector!/ Local Road 800 15 2069 968 969 0.922 10 1

Collector!/ Local Road 800 15 2070 969 968 0.922 10 1

Colector!/ Local Road 800 15 2071 905 969 0.53 10 1

1Collector!/ Local Road 800 1 5 Page 37 of 38 Page37 o 38Appendix C - Page 38 of 44

Appendix C Byron NGS Roadway Network Data Table Link #

U-Node D-Node Length Lane Number of Roadway Type Satuattion Flow FFS (mph)

Link _UNod D-Node_

(mi)

Width (ft)

Lanes Rate (vehhr)_FFS_(mph) 2072 969 905 0.53 10 1

Collector/ Local Road 800 15 2073 969 970 0.421 10 1

Collector/ Local Road 800 15 2074 970 969 0.421 10 1

Collector / Local Road 800 15 2075 333 970 0.249 12 1

Principal Arterial 1700 35 2076 970 333 0.249 12 1

Principal Arterial 1700 35 2077 332 970 0.166 12 1

Principal Arterial 1700 35 2078 970 332 0.166 12 1

Principal Arterial 1700 35 2079 353 961 1.593 10 1

Collector / Local Road 800 15 2080 961 353 1.593 10 1

Collector / Local Road 800 15 2081 961 962 4.153 10 1

Collector / Local Road 800 15 2082 962 961 4.153 10 1

Collector/ Local Road 800 15 2083 918 967 1.089 10 1

Collector / Local Road 800 15 2084 967 918 1.089 10 1

Collector / Local Road 800 15 2085 966 967 0.407 10 1

Collector / Local Road 800 15 2086 967 966 0.407 10 1

Collector I Local Road 800 15 2087 965 966 1.357 10 1

Collector/ Local Road 800 15 2088 966 965 1.357 10 1

Collector / Local Road 800 15 2089 964 965 0.661 10 1

Collector I Local Road 800 15 2090 965 964 0.661 10 1

Collector / Local Road 800 15 2091 963 964 0.831 10 1

Collector/ Local Road 800 15 2092 964 963 0.831 10 1

Collector/ Local Road 800 15 2093 341 966 1.122 10 1

Collector/ Local Road 800 15 2094 966 341 1.122 10 1

Collector / Local Road 800 15 2095 359 963 0.334 12 1

Principal Arterial 1700 55 2096 963 359 0.334 12 1

Principal Arterial 1700 55 2097 853 963 0.57 12 1

Principal Arterial 1700 55 2098 963 853 0.57 12 1

Principal Arterial 1700 55 2099 956 962 6.082 10 1

Collector / Local Road 800 15 2100 962 956 6.082 10 1

Collector / Local Road 800 15 2101 918 962 2.216 10 1

Collector / Local Road 800 15 2102 962 918 2.216 10 1

Collector/ Local Road 800 15 Page 38 of 38 Appendix C - Page 39 of 44

Appendix C Byron NGS Node Data Table Note: Coordinates in NAD83 State Plane Illinois West Node #

X-Coord Y-Coord Control Type 113 797193.61 1981786.7 Two-way yield 116 797497.47 1947233.6 Two-way yield 117 797313.74 1944471.4 Two-way yield 121 796351.89 1921295.8 Two-way yield 123 796220.12 1918320.7 Two-way yield 127 675201.69 2044968.6 Two-way stop 128 675200.67 2044886.9 Two-way stop 132 706898.68 1991600.9 Two-way stop 135 740483.29 1986622.1 Two-way stop 136 777363.19 1980464 Two-way stop 137 798344.47 1980031.2 Diverge - Uncontrolled 138 797858.76 1980042.4 Two-way stop 139 796415.23 1980027.4 Two-way stop 140 796490.55 1980028.2 Two-way stop 141 797799.06 1980042.9 Two-way stop 143 795177.02 1980009.5 Diverge - Uncontrolled 144 782656.01 1980515.8 Two-way stop 149 798204.77 1945957.8 Two-way stop 150 796598.16 1945923.3 Two-way stop 151 798205.93 1945930.9 Two-way stop 152 795975.82 1945935.7 Diverge - Uncontrolled 154 785266.65 1945879.4 All-way stop 158 769585.22 1921936.4 All-way stop 159 796977.23 1919524.9 Two-way stop 160 795620.01 1919472.5 Two-way stop 161 796979.78 1919478.9 Two-way stop 162 795620.71 1919517.4 Two-way stop 166 784153.43 1907718 Two-way stop 167 784160.77 1908257.3 Diverge - Uncontrolled 168 784188.81 1907717.7 Two-way yield 170 784190.13 1906598.9 Diverge - Uncontrolled 171 784151.67 1906599.2 Two-way yield 179 712725.55 1949495.3 Signalized - Actuated 180 685821.59 1962565.3 Signalized - Actuated 184 670538.88 1889429.8 Signalized - Flashing 186 784274.39 1919390.3 Signalized - Flashing 196 796490.61 1980006.1 Two-way stop 197 797798.82 1980013.7 Two-way stop 198 796414.06 1980007.1 Two-way stop 199 797858.52 1980013.3 Two-way stop 201 796598.33 1945945.2 Two-way stop 202 798770.09 1945953.3 Diverge - Uncontrolled Page 1 of 5 Appendix C - Page 40 of 44

Appendix C Byron NGS Node Data Table Node #

X-Coord Y-Coord Control Type 204 743664.25 1903340.4 Two-way stop 208 632907.67 2047422.4 Signalized - Flashing 209 671717.66 1885639.5 Signalized - Flashing 223 693806.38 1990124.3 Two-way stop 224 701610.62 1991636.4 Two-way stop 227 693783.9 1997728.9 Two-way stop 229 683313.55 1962544.6 Two-way stop 235 691134.37 1962543 Two-way stop 236 699035.06 1962637.9 Two-way stop 237 702974.36 1963125.6 Two-way stop 239 708745.1 1963912.9 Two-way stop 240 645458.67 1945874.5 Two-way stop 253 691143.13 1960006.2 Two-way stop 254 693074.32 1959537.3 Two-way stop 256 705377.9 1954484.3 Two-way stop 276 668184.07 1914393.9 Two-way stop 277 668665.28 1924811.3 Two-way yield 278 668888.95 1930078.6 Two-way stop 279 692478.48 1929764.1 Two-way stop 287 700871.74 1945500 Two-way stop 289 711417.24 1945796.8 Signalized - Flashing 295 743889.69 1910344.7 Two-way stop 298 716341.54 1939066.3 Two-way stop 299 743143.79 1933590.9 Two-way stop 307 753542.51 1982737 Two-way stop 308 754315.92 1982732.9 Two-way stop 309 756536.17 1982731.6 Two-way stop 310 764349.04 1981305.3 Two-way stop 313 756324.33 1966717.4 Two-way stop 314 794377.7 1964906.5 Two-way stop 315 794920.26 1964832.8 Two-way stop 316 756489.52 1945596.2 Two-way stop 318 774668.02 1945829.9 Two-way stop 320 743098.35 1945479.7 Two-way stop 322 782672.15 1966747.1 Two-way stop 323 782567.33 1997448.6 Diverge - Uncontrolled 326 712026.25 1949521.7 Two-way stop 330 715097.93 1949402.2 Signalized - Flashing 331 716819.06 1949342.7 Signalized-Actuated 338 714978.81 1967185.6 Two-way stop 341 733961.64 1989630.7 Signalized - Actuated 343 733340.2 1981093.1 Two-way stop 344 734458.5 1982501 Two-way stop 347 728012.98 1965306.9 Two-way stop Page 2 of 5 Appendix C - Page 41 of 44

Appendix C Byron NGS Node Data Table Node #

X-Coord Y-Coord Control Type 348 728004.47 1967982.1 Two-way stop 350 701679.53 2017922.7 Two-way stop 351 706216.53 2017914.1 Two-way yield 352 706887.95 2017913.1 All-way stop 353 722629.01 1991706.6 Two-way yield 356 731832.63 1989592.7 Signalized - Actuated 360 738292.33 2000293 Two-way stop 361 738583.83 2004761.8 Two-way stop 362 739682.51 2008919.6 Two-way stop 369 682369.83 1940477 Two-way stop 371 689154.1 1912329.8 Two-way stop 373 705593.76 1909512.1 Two-way stop 377 716188.17 1936973.6 Two-way stop 381 713397.9 1970188.9 Two-way stop 382 785251.16 1956498.8 Two-way stop 383 784384.78 1961779.5 Two-way stop 385 744647.92 1919056.7 Two-way stop 386 754836.49 1985424.7 Two-way stop 387 743151.86 1932268 Two-way stop 388 777481.52 1921963.5 Two-way stop 396 685808.44 1970450.7 Two-way stop 397 722691.82 1967943.2 Two-way stop 400 699038.78 1958071 Two-way stop 401 756396.64 1956366.5 Two-way stop 402 714693.26 1950759 Two-way stop 409 784374.69 1922014 Signalized - Actuated 417 725890.58 1947843.8 Two-way stop 418 738441.57 2046374.1 Two-way stop 420 738432.64 2046297.7 Two-way stop 484 756810.07 2041156 Two-way stop 485 755396.12 2041611 Two-way yield 493 756804.92 2040357.8 Two-way stop 494 758217.27 2040559 Two-way yield 542 765981.57 2033186 Two-way stop 543 765045.86 2034151.5 Two-way yield 546 765098.72 2032591.1 Two-way stop 553 766148.78 2031374.9 Two-way yield 567 761747.58 2030483.9 Two-way stop 577 756796.78 2028703.9 Two-way stop 582 774195.58 2025607.7 Signalized - Flashing 585 784105.07 2024881.9 Signalized - Flashing 587 769231.47 2024916.1 All-way stop 588 761734.6 2024922.4 Two-way stop 590 784131.87 2024659.1 Two-way yield Page 3 of 5 Appendix C - Page 42 of 44

Appendix C Byron NGS Node Data Table Node #

X-Coord Y-Coord Control Type 591 756785.75 2024952.4 Two-way stop 592 795898.09 2024044.2 Signalized - Flashing 593 774195.07 2024882.2 Diverge - Uncontrolled 594 774191.26 2024762 Two-way yield 596 794901.18 2023544.2 Two-way yield 600 774186.39 2023674 Two-way yield 602 784297.98 2023509.7 Two-way yield 604 784071.28 2023606.4 Two-way yield 605 782645.54 2023513.1 Two-way yield 611 772907.01 2023549.1 Two-way yield 612 795898.09 2022997.1 Signalized - Flashing 613 797122.16 2023500.6 Two-way yield 615 784138.34 2023375.2 Two-way yield 617 783998.26 2023434.7 Two-way yield 620 774181.78 2023420.9 Two-way yield 623 751571.2 2023353.3 Two-way stop 624 795892.76 2022295.7 Signalized - Flashing 625 784055.93 2022148.7 Two-way yield 627 774177.87 2022365.6 Two-way yield 629 774180.01 2022036 Diverge - Uncontrolled 632 706775.51 2023217.6 Two-way stop 633 780108.44 2020893.1 All-way stop 636 794593.79 2019638.8 All-way stop 637 788064.21 2019558.4 All-way stop 638 784046.01 2019611.7 Signalized - Flashing 639 781243.54 2019610.5 Two-way stop 640 765750.37 2019606.7 Two-way stop 641 774235.31 2019373.4 Signalized -Actuated 643 794587.32 2018309.7 Two-way stop 644 730494.1 2018928.4 Two-way stop 645 730840.92 2018924.5 Two-way stop 646 730491.07 2018651.4 Two-way stop 647 774641.38 2017412.2 Signalized - Actuated 648 706796.32 2018493.9 Two-way stop 649 794609.06 2014355.3 Two-way stop 650 788041.95 2014275.3 Two-way stop 651 783960.82 2014299.3 Signalized - Actuated 652 780131.72 2014325.6 Two-way stop 653 783954.92 2012994.7 Two-way stop 654 764268.19 2012765.4 Two-way stop 656 766655.1 2010078.7 Two-way stop 657 756681.46 2010307.1 Two-way stop 659 765479.81 2008766.8 Two-way stop 660 765979.55 2009155.7 Two-way stop Page 4 of 5 Appendix C - Page 43 of 44

Appendix C Byron NGS Node Data Table Node #

X-Coord Y-Coord Control Type 661 783359.82 2004388 Two-way stop 662 783430.15 2004369.1 Two-way stop 663 770857.61 2004568 Two-way stop 665 797748.08 2003815.4 Two-way stop 666 797158.16 2005593.7 Two-way yield 667 796422.9 2003798.3 Two-way stop 670 763769.51 2003679.6 Two-way stop 671 758832.63 2003784.2 Two-way stop 672 797044.21 2001977.7 Two-way yield 674 756715.24 2002090.8 Two-way stop 676 782611.56 2004881.4 Two-way stop 693 635812.29 2047416.3 Signalized - Flashing 698 675317.63 2033607.6 Two-way stop 700 640987.76 2047378.4 Two-way stop 701 640989.83 2039462 Two-way stop 705 670981.67 1888033.9 Signalized - Flashing 706 667418.29 1893915 Signalized - Flashing 710 691132.18 1895747.4 Two-way stop 711 690987.86 1896003.4 Two-way stop 720 784030.49 2007946.4 Diverge - Uncontrolled 733 695933.27 1920522 Two-way stop 738 709616.42 1896882.6 Two-way stop 741 722675.54 1970567.3 Two-way stop 742 722368.2 1983509.1 Two-way stop 743 782641.43 1982582.3 Two-way stop 758 646800.2 1880588.8 Diverge - Uncontrolled 780 759851.92 1920748.8 Two-way stop 804 784046.66 2020767.6 Diverge - Uncontrolled 805 800188.91 2020130.4 Two-way yield 823 632944.05 2042141.5 Signalized - Flashing 831 797953.51 2014393.7 Two-way stop 841 756602.23 1996665.2 Two-way stop 845 790770.14 1966747.5 Two-way stop 855 734344.67 1987680.5 Two-way yield 872 685741.18 1895990.6 Two-way yield 873 685694.89 1895911.4 Two-way stop 874 685652.3 1895856.8 Diverge - Uncontrolled 875 685759 1895891.9 Two-way yield 876 635674.04 2042118.8 Two-way stop 963 737026.22 1992496.5 Two-way yield Note: Coordinates in NAD83 State Plane Illinois West Nodes which reflect changes in roadway properties (number of lanes, speed limit, capacity, etc.) at points along the link are omitted from this list.

Page 5 of 5 Appendix C - Page 44 of 44

Va ARCADIS Appendix D Maps Depicting Travel Speed along Road Network (winter day, fair weather, full EPZ)

Evacuation Hour 1 Avg Speed (mph)

Links

___<=

0.0

<= 20.0

<= 40.0

<= 60.0

> 60.0 VISUM 11.52 PTV AG NWintDayl Omile.ver.net erstellt am: 06.07.2012 App D page 1 of 6

Evacuation Hour 2 Avg Speed (mph)

Links

<= 0.00

<= 20.00

<= 40.00

<= 60.00

> 60.00 VISUM 11.52 PTV AG INWintDayl Omile.ver. net lerstellt am: 06.07.2012 App D page 2 of 6

Evacuation Hour 3 Avg Speed (mph)

  • t...%*

Links

<= 0.00

<= 20.00

<= 40.00

<= 60.00

> 60.00 VISUM 11.52 PTV AG NWintDayl Omile.ver.net erstellt am: 06.07.2012 App D page 3 of 6

I Evacuation Hour 4 Avg Speed (mph)

Links

<= 0.00

<= 20.00

<= 40.00

<= 60.00

> 60.00 VISUM 11.52 PTV AG NWintDayl Omile.ver.net lerstellt am: 06.07.2012 App D page 4 of 6

Evacuation Hour 5 Avg Speed (mph)

Links

<= 0.00

<= 20.00

<= 40.00

<= 60.00

> 60.00 VISUM 11.52 PTV AG NWintDayl Omile.ver.net Ierstellt am: 06.07.2012 App D page 5 of 6

Evacuation Hour 6 Avg Speed (mph)

Links

<= 0.00

<= 20.00

<= 40.00 V

/<=

60.00

> 60.00 VISUM 11.52 PTV AG NWintDayl Omile.ver.net erstellt am: 06.07.2012 App D page 6 of 6