Category:License-Application for (Amend/Renewal/New) for DKT 30
[Table view] Category:40
MONTHYEARML21347A9742021-12-13013 December 2021 Independent Spent Fuel Storage Installation Decommissioning Funding Plans ML21088A1802021-03-29029 March 2021 Decommissioning Funding Status Reports ML19088A0492019-03-29029 March 2019 Decommissioning Funding Status Reports L-PI-17-027, License Amendment Request to Revise the NDE Inspection Interval for Special Lifting Devices2017-08-0404 August 2017 License Amendment Request to Revise the NDE Inspection Interval for Special Lifting Devices ML17087A2462017-03-28028 March 2017 Decommissioning Funding Status Reports ML13247A3492013-08-28028 August 2013 Revised ISFSI Bases, Includes Revised Record of Revision, Revised Current Page List, and Revision 9 to Page B 3.1.5-1 ML13084A0502013-03-22022 March 2013 Enclosures - Decommissioning Funding Status Reports ML13126A1142013-03-22022 March 2013 Plants - Decommissioning Funding Status Reports L-PI-11-075, Letter from Xcel Energy License Amendment Request for Spent Fuel Pool Criticality Changes2011-08-19019 August 2011 Letter from Xcel Energy License Amendment Request for Spent Fuel Pool Criticality Changes ML1009101352010-03-31031 March 2010 Independent Spent Fuel (Isfsi), Decommissioning Funding Status Reports ML0909100822009-03-31031 March 2009 ISFSI, and Monticello, Decommissioning Funding Status Reports L-PI-08-062, Irradiated Fuel Management Plan and Preliminary Decommissioning Cost Estimates2008-08-0808 August 2008 Irradiated Fuel Management Plan and Preliminary Decommissioning Cost Estimates L-HU-07-011, Plants, Decommissioning Funding Status Reports2007-03-30030 March 2007 Plants, Decommissioning Funding Status Reports L-HU-05-008, Decommissioning Funding Status Reports2005-03-31031 March 2005 Decommissioning Funding Status Reports ML0427104792004-09-14014 September 2004 Final Status Survey Release Record FA-0600 Primary Auxiliary Building Survey Unit 09 ML0329009652003-10-16016 October 2003 Decommissioning Funding Status Reports - Supplemental Response for Duane Arnold, Kewaunee, Monticello, Palisades, Point Beach, Units 1 and 2, and Prairie Island, Units 1 and 2 ML0309300582003-03-31031 March 2003 Decommissioning Funding Status Reports 2021-03-29
[Table view] Category:70
MONTHYEARML21347A9742021-12-13013 December 2021 Independent Spent Fuel Storage Installation Decommissioning Funding Plans ML21088A1802021-03-29029 March 2021 Decommissioning Funding Status Reports ML19088A0492019-03-29029 March 2019 Decommissioning Funding Status Reports L-PI-17-027, License Amendment Request to Revise the NDE Inspection Interval for Special Lifting Devices2017-08-0404 August 2017 License Amendment Request to Revise the NDE Inspection Interval for Special Lifting Devices ML17087A2462017-03-28028 March 2017 Decommissioning Funding Status Reports ML13247A3492013-08-28028 August 2013 Revised ISFSI Bases, Includes Revised Record of Revision, Revised Current Page List, and Revision 9 to Page B 3.1.5-1 ML13084A0502013-03-22022 March 2013 Enclosures - Decommissioning Funding Status Reports ML13126A1142013-03-22022 March 2013 Plants - Decommissioning Funding Status Reports L-PI-11-075, Letter from Xcel Energy License Amendment Request for Spent Fuel Pool Criticality Changes2011-08-19019 August 2011 Letter from Xcel Energy License Amendment Request for Spent Fuel Pool Criticality Changes ML1009101352010-03-31031 March 2010 Independent Spent Fuel (Isfsi), Decommissioning Funding Status Reports ML0909100822009-03-31031 March 2009 ISFSI, and Monticello, Decommissioning Funding Status Reports L-PI-08-062, Irradiated Fuel Management Plan and Preliminary Decommissioning Cost Estimates2008-08-0808 August 2008 Irradiated Fuel Management Plan and Preliminary Decommissioning Cost Estimates L-HU-07-011, Plants, Decommissioning Funding Status Reports2007-03-30030 March 2007 Plants, Decommissioning Funding Status Reports L-HU-05-008, Decommissioning Funding Status Reports2005-03-31031 March 2005 Decommissioning Funding Status Reports ML0427104792004-09-14014 September 2004 Final Status Survey Release Record FA-0600 Primary Auxiliary Building Survey Unit 09 ML0329009652003-10-16016 October 2003 Decommissioning Funding Status Reports - Supplemental Response for Duane Arnold, Kewaunee, Monticello, Palisades, Point Beach, Units 1 and 2, and Prairie Island, Units 1 and 2 ML0309300582003-03-31031 March 2003 Decommissioning Funding Status Reports 2021-03-29
[Table view] Category:License-Application for Dry Cask ISFSI DKT 72
MONTHYEARML13247A3492013-08-28028 August 2013 Revised ISFSI Bases, Includes Revised Record of Revision, Revised Current Page List, and Revision 9 to Page B 3.1.5-1 ML11304A0682011-10-20020 October 2011 Independent Spent Fuel Storage Installation (ISFSI) - License Renewal Application ML1131405182011-10-20020 October 2011 Redacted - Prairie Island Independent Spent Fuel Storage Installation (ISFSI) - Application for Renewed ISFSI Site-Specific License 2013-08-28
[Table view] |
Text
T-02 PASSPORT DOCUMENT To NRC DOC CONTROL DESK COPY #383 Facility PI Department TRANSMITTAL Address ONE WHITE FLINT NORTH il~Hg I lll llllail N 11555 ROCKVILLE PIKE ROCKVILLE, MD 20852-2738 Page:
~ ~lnmiliI From C-DOC CNTRL-PI Attention:
Address : 1717 WAKONADE DR EAST City WELCH State: MN Postal Code: 55089 Country UNITED STATES Email Contact Date/Time 08/28/2013 0'5:48 Transmittal Group Id: 0000025413 Trans No. 000225895
Title:
Total Items: 00001 Item Facility Type Sub Document Number Sheet Doc Status Revision Doc Date Copy # Media Cpys 0001 PI LIC BASE ISFSI BASES ISSUED 009 383 HC 01 If a document was not received or is no longer required check the response below and return to sender.
Documents noted above not received (identify those not received).
I no longer require distribution of these documents (identify those no longer required).
Date: Signature:
ISFSI BASES UPDATING INSTRUCTIONS Revision 9 ISFSI BASES REMOVE Paqe Revision Document Type B RoR-1 12/10/12 Record of Revision A 12/10/12 Current Page List Page Revision Section/Chapter B 3.1.5-1 7 B 3.1
_ _ _ _ I _ __ i __
t *1-I +
Prairie Island Units 1 and 2 ISFSI-B-1 8/27/13
PRAIRIE ISLAND NUCLEAR GENERATING PLANT INDEPENDENT SPENT FUEL STORAGE INSTALLATION RECORD OF REVISION BASES CHANGES AND LICENSE AMENDMENTS NSPM Date of License Revision Issue Amendment No. Remarks (REV) No.
I thrnn h ý 5
Or;o nnl Rt
- xunrp AT nrt nf hnoinl Specifications 7 8/20/2010 7 Initial Issue of revised format and Inclusion of TN-40HT design.
8 12/12/2012 Clarify "helium environment" requirement in ISFSI SR 3.1.2.1.
9 8/27/13 Revise B 3.1.5 paraphrase of regulatory requirements.
Prairie Island ISFSI B RoR- 8 /27/13
BASES CURRENT PAGES PAGE DATE PAGE REVISION No.
B RoR- 1 8/27/13 B 3.1.3-1 7 A 8/27/13 B 3.1.3-2 7 i 8/20/10 B 3.1.3-3 7 B 3.1.3-4 7 B 3.1.4-1 7 B 3.1.4-2 7 B 3.1.4-3 7 B 3.1.5-1 9 PAGE REVISION No.
B 3.1.5-2 7 B 2.0-1 7 B 3.1.5-3 7 B 2.0-2 7 B 3.1.5-4 7 B 3.0-1 7 B 3.1.5-5 7 B 3.0-2 7 B 3.1.6-1 7 B 3.0-3 7 B 3.1.6-2 7 B 3.0-4 7 B 3.1.6-3 7 B 3.0-5 7 B 3.2.1-1 7 B 3.0-6 7 B 3.2.1-2 7 B 3.0-7 7 B 3.2.1-3 7 B 3.0-8 7 B 3.2.2-1 7 B 3.0-9 7 B 3.2.2-2 7 B 3.0-10 7 B 3.2.2-3 7 B 3.0-11 7 B 3.3.1-1 7 B 3.1.1-1 7 B 3.3.1-2 7 B 3.1.1-2 7 B 3.3.1-3 7 B 3.1.1-3 7 B 3.3.1-4 7 B 3.1.2-1 7 B 3.4.1-1 7 B 3.1.2-2 7 B 3.4.1-2 7 B 3.1.2-3 7 B 3.4.1-3 7 B 3.1.2-4 8 B 3.1.2-5 7 Prairie Island ISFSI A 8/27/13
Cask Interseal Pressure B 3.1.5 B 3.1 CASK INTEGRITY B 3.1.5 Cask Interseal Pressure BASES BACKGROUND A cask is loaded, dried, and sealed prior to being transported to the ISFSI and placed on a storage pad. The cask is designed with redundant seals to contain the radioactive material. In addition, 10 CFR 72.122(h)(4) requires that confinement systems have the capability of being monitored. The monitoring systems provide:
- a. the capability to monitor interseal pressure that will indicate if cask seal integrity is compromised; and
- b. local alarms to indicate that potential seal degradation has occurred.
It is necessary to verify cask seal integrity at regular intervals to ensure the cask's interseal containment boundary is being maintained and to verify there is no seal leakage to the environment.
APPLICABLE The confinement of radioactive material during the storage of spent SAFETY fuel in a cask is ensured by the use of multiple confinement barriers ANALYSIS and systems. The barriers relied upon are the uranium dioxide fuel pellet matrix, the metallic fuel cladding tubes in which the fuel pellets are contained, and the cask in which the fuel assemblies are stored. Long-term integrity of the fuel cladding depends on storage in an inert atmosphere. This is accomplished by removing water from the cask cavity and backfilling the cavity with an inert gas.
The failure of storage cask confinement capability is considered in Prairie Island ISFSI B 3.1.5-1 Revision 9 1