ML13219A033

From kanterella
Jump to navigation Jump to search
Email from J. Poehler to G. Cheruvenki, FW: Peer Review of SE Input for Vermont Yankee Core Plate Bolt Analysis
ML13219A033
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 02/14/2012
From: Jeffrey Poehler
Office of Nuclear Reactor Regulation
To: Ganesh Cheruvenki
Office of Nuclear Reactor Regulation
References
FOIA/PA-2013-0139
Download: ML13219A033 (1)


Text

Poehler, Jeffrey 7-From:

Poehler, Jeffrey Sent:

Tuesday, February 14, 2012 1:19 PM To:

Cheruvenki, Ganesh

Subject:

RE: Peer Review of SE Input for Vermont Yankee Core Plate Bolt Analysis (ME6248)

Thanks, Ganesh.

I'm going to forward my input to Pani. I anticipate that Pani and I will need to meet to figure out how we are going to integrate my input into his SE.

Jeff From: Cheruvenkl, Ganesh Sent: Tuesday, February 14, 2 1 AM To: Poehler, Jeffrey

Subject:

RE: Peer Review of SE Input for Vermont Yankee Core Plate Bolt Analysis (ME6248)

Jeff-Looks good-specially the statistical approach From: Poehler, Jeffrey Sent: Tuesday, February 14, 2012 9:25 AM To: Cheruvenki, Ganesh Cc: Purtscher, Patrick

Subject:

RE: Peer Review of SE Input for Vermont Yankee Core Plate Bolt Analysis (ME6248)

Did you guys have time to comment?

From: Cheruvenki, Ganesh Sent: Tuesday, February 07, 2012 12:07 PM To: Poehler, Jeffrey

Subject:

RE: Peer Review of SE Input for Vermont Yankee Core Plate Bolt Analysis (ME6248)

Will do.

From: Poehler, Jeffrey Sent: Tuesday, February 07, 2012 10:45 AM To: Cheruvenki, Ganesh Cc: Purtscher, Patrick

Subject:

Peer Review of SE Input for Vermont Yankee Core Plate Bolt Analysis (ME6248)

Ganesh, As discussed yesterday, please peer review (technical only) my SE input for Vermont Yankee. Use TAC ME6248. Note that it is not a complete SE because Pani has the lead on the SE. He can integrate my inputs into the structure of his SE.

If you can give me comments by the end of the week that would be fine.

Pat, I copied you so if you have time to review your comments would also be appreciated.

Thanks, 23