Lr Hearing - Draft RAI on Reactor Vessel Internals Inspection Plan
ML13198A062
Person / Time
Site: Indian Point  
Issue date: 07/17/2013
From:
Office of Nuclear Reactor Regulation
To:
Division of License Renewal
References
Download: ML13198A062 (3)


Text

1 IPRenewal NPEmails From:

Green, Kimberly Sent:

Wednesday, July 17, 2013 7:42 AM To:

Waters, Roger M.

Cc:

Poehler, Jeffrey; IPRenewal NPEmails

Subject:

RE: Draft RAI on Reactor Vessel Internals Inspection Plan

Roger, We are available for a phone call on Friday at 1:00 pm. Ill will arrange for a bridge line and send you the information shortly.

Kim From: Waters, Roger M. [1]

Sent: Tuesday, July 16, 2013 3:10 PM To: Green, Kimberly

Subject:

RE: Draft RAI on Reactor Vessel Internals Inspection Plan

Kim, We would like the call to be at 1 pm on Friday - is that still good for you?

During the call we will walk through each RAI to ensure that we have a clear understanding.

Roger From: Green, Kimberly [2]

Sent: Monday, July 15, 2013 10:58 AM To: Waters, Roger M.

Cc: IPRenewal NPEmails; Poehler, Jeffrey

Subject:

RE: Draft RAI on Reactor Vessel Internals Inspection Plan

Roger, Jeff Poehler is available Wednesday before noon, Thursday and Friday all day. Please let me know which of these days and times are convenient for Entergy.
Thanks, Kim From: Waters, Roger M. [3]

Sent: Monday, July 15, 2013 10:50 AM To: Green, Kimberly

Subject:

RE: Draft RAI on Reactor Vessel Internals Inspection Plan

Kim, We will need a conference call to discuss, at a minimum, draft RAI 11-b. We are also reviewing the 3 other RAIs to determine whether we need clarification on those.

2 Roger From: Green, Kimberly [4]

Sent: Wednesday, July 10, 2013 3:53 PM To: Waters, Roger M.

Cc: IPRenewal NPEmails; Poehler, Jeffrey

Subject:

Draft RAI on Reactor Vessel Internals Inspection Plan

Roger, Attached is a draft request for additional information (RAI) regarding the Indian Point Reactor Vessel Internals Inspection Plan and responses to previous RAIs.

Please review the draft RAIs and let me know if Entergy requires a phone call. The purpose of the phone call would be to obtain clarification on the staffs requests.

Thanks, Kim (301) 415-1627 kimberly.green@nrc.gov

Hearing Identifier:

IndianPointUnits2and3NonPublic_EX Email Number:

4306 Mail Envelope Properties (F5A4366DF596BF458646C9D433EA37D701090B041602)

Subject:

RE: Draft RAI on Reactor Vessel Internals Inspection Plan Sent Date:

7/17/2013 7:41:30 AM Received Date:

7/17/2013 7:41:31 AM From:

Green, Kimberly Created By:

Kimberly.Green@nrc.gov Recipients:

"Poehler, Jeffrey" <Jeffrey.Poehler@nrc.gov>

Tracking Status: None "IPRenewal NPEmails" <IPRenewal.NPEmails@nrc.gov>

Tracking Status: None "Waters, Roger M." <rwater1@entergy.com>

Tracking Status: None Post Office:

HQCLSTR01.nrc.gov Files Size Date & Time MESSAGE 2083 7/17/2013 7:41:31 AM Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received: