From:
Hickman, John Sent:
Monday, June 10, 2013 4:48 PM To:
Donald A. Beckman
Subject:
Another Heavy Loads Amendment Question Attachments:
Question on page 24 of 53.pdf
- Don, Please see the attached page markup. Dan needs you to explain:
(1) the relationship in between shear wall column P7, P4, etc. to the SFP column 17 to 23 and P to W? (Yellow Highlight),
(2) missing Value (Green Highlight), and (3) below Table, foot note *SSE Max. Moment (IR = 1.111). This interaction ratio (IR) is unacceptable (need to see a conservative reanalysis [method] that has an IR below unity.