Text
From:
Hickman, John Sent:
Thursday, June 06, 2013 10:47 AM To:
Donald A. Beckman
Subject:
Heavy Loads Amendment
- Don, On page 19 of 53 of your May 16, 2013, supplement (ZS-2013-0194) you state: The Zion DSAR requires allowable stresses for OBE to be in accordance with the AISC specification. A 1/3 allowable stress increase is permitted for earthquake forces per the specification. Can you please provide a specific reference to where this statement is in the DSAR.
- Thanks, John B. Hickman Reactor Decommissioning Project Manager 301-415-3017