Appendix E Microbiological Correspondence Byron Station Environmental Report
This Page Intentionally Left Blank
Byron Station Environmental Report Appendix E Microbiological Correspondence Byron and Braidwood Stations, Units 1 and 2 E-iii License Renewal Application Table of Contents Letter Page Michael P. Gallagher, Exelon Generation, to David W. Culp, Ph.D., Illinois Department of Public Health................................................................................................................... E-1 Ken McCann, MA, LEHP, Illinois Department of Public Health, to Michael P. Gallagher, Exelon Generation.......................................................................................................................... E-4
This Page Intentionally Left Blank
on Generation January 23,201 3 David W. Culp, Ph.D., Deputy Director Illinois Department of Public Health Office of Health Protection 525 W. Jefferson St., 2"* Floor Springfield, Illinois 62761 -0001
SUBJECT:
Exelon Generation, LLC - Byron Station Units 1 and 2 License Renewal Project.
Request for information on Thermophilic Pathogens - Ogle County
Dear Dr. Culp:
In May 2013, Exelon Generation Company, LLC (Exelon Generation; a subsidiary of Exelon Corporation) plans to apply to the Nuclear Regulatory Commission (NRC) for renewal of the operating licenses for Byron Station (Byron), Units 1 and 2. The Byron Units began commercial operation in 1985 and 1987, respectively. The existing operating iicense for Byron Unit 1 expires October 31, 2024, and the existing operating license for Byron Unit 2 expires November 6,2026. License renewal will extend the license terns to October 31,2044 and November 6, 2046, respectively.
The NRC requires that the license renewal application include an environmental report assessing potential impacts from license renewal activities, including continued operations.
One such impact is the "impact of the proposed action [license renewal] on public health from themophitic organisms in the affected water" (1 0 CFR 51.53(~)(3)(ii)(G)). Accordingly, we are contacting you to obtain input regarding potential public health concerns associated with the enteric pathogens Salmonella spp and Shigella spp as well as Pseudomonas aeruginosa bacterium, thermophilic fungi, Legionelia spp in unusually high wncenlrations, and the free-living amoeba of the genera Naegieria and Acanthomoeba. Of greatest concern is the genus Naqieria, comprising four species. To date only one species, N. fouvleri, has been determined to be pathogenic in humans, Project Features Byron is located in northern Illinois near the center of Ogle Gounty, approximately 90 miles (mi) west-northwest of Chicago, 17 mi southwest of Rockford, and 3.7 mi south-southwest of the City of Byron. The Rock River is approximately 2 mi w s t of the western site boundary, The fallowing paragraphs prervide background information on the Byron cooling system, and Exelon Generation" assessment d potential effects on the public. We are requesting your help to identify issues regarding thermophilic organisms that we may have overlooked, but that should be addressed in the eron license renewal environmental repart. We are partialarty interested in learning of any information your staff believes muld expedite the NRC's review of the Byron license renewal application.
Byron and Braidwood Stations, Units 1 and 2 License Renewal Application Page E-1 Byron Station Environmental Report Appendix E - Microbiological Correspondence
Cooling System Each of Byron's two units has a closed-cycle recirculating cooling water system with a natural draft mling tower. An open cooling water basin and intake flume is locatsd bemeen the two natural draft cooling towers. Makeup water for the cooling towers to replace water lost to evaporation, drift, and blo\\nrdovvn comes from the Rock River. Blowdown water is returned to the Rock River through an NPDES-permi~ed (110048313) ouffall (Ou~aIl001) for the purpose of reducing dissolved solids that build up in the circulating water system as the condenser cooling water recycles through the natural draff cooling towrs, Byron operates an onsite package sewage treatment plant. The effluent from the sewage treatment plant mixes with the blowdown water discharge before both are released through Outfall 001. The ouffall structure discharges through a 275-ft-long rip-rapped channel into the east side of the river approximately 200 feet downstream of the intake structure.
The flow rate of blowdown discharged to Rock River ranges between 29 and 38 cubic feet per second (cfs), depending on water chemisw (concentrations of mineral solids) in the cooling tower basins Results of thermal modeling prior to construction of the station predicted that the blowdown would create a thermal plume with a surface area ranging from 0.45 to 2.8 acres between May and August and that discharge temperatures would meet water quality standards.
Under Illinois Administrative Code (IAC) Titb 35, Section 302.1 02(b)(8), "a [temperature] mixing zone must not contain more than 25 percent of the cross-sectional area or volume of flow of a stream." In Special Condition 3 of NPDES permit 110048313, the Illinois EPA has determined that Byron's blowdown discharge meets this criterion as well as the thermal water quality standard in Title 35, Section 302.21 1. In addition, as specified in Speciat Condition 12 of NPDES permit lL0048313, Byron must explicitly demonstrate compliance with the thermal water quality standard on a daily basis during times when the Rock River flow is less than 2,400 cfs, or the temperature difference between the main river temperature and the water quality standard is less than 3°F.
Byron also has an agreement with the illinois Department of Natural Resources (DNR) to limit consumption of water from the Rock River for makeup to the Byron cooling systems to no more than 9 percent of total river flow during times when the river flow rate drops below 679 cfs. To maintain compliance, Byron adjusts the circulating water system makeup and blowdown flaws, and if necessary, would reduce the power output from the units.
Byron water systems that recirculate and blow down to the Rock River are treated with bioddes, including sodium hypochlorite and sodium bromide, for biofouling control. Additionally, sulfuric acid, polyphosphate, potassium phosphonate, acrylic polymer, and biazole are used for scaling control; zinc for corrosion control; and polyacrylate for silt dispersal. Makeup from the river is treated with a low mncentration of copper ions to prevent zebra mussei infestation.
An Environmental Protection Pian is incorporated in the NRC operating licenses for Byron. The Environmental Protedion Pbn incorporates the NPDES permit by reference. Blowdown flow and temperature are monitored and reported to the Illinois EPA in monthly NPDES Dis&arge Monitoring Reports.
The stream segment (11-P-20) of the Rock River remiving the discharge from Byron Outfall 001 is idenWied in the Deeember 201 2 ltlinois fntwmfed Wafer Qtrality Reporf and Secfim 303fd)
Li& as fully supporting primary (and semndary) contact, These designations are bas& on fecal Byron and Braidwood Stations, Units 1 and 2 License Renewal Application Page E-2 Byron Station Environmental Report Appendix E - Microbiological Correspondence
coliform measurements only, Primary contact is "any recreational or other water use in which there is prolonged and intimate contact with the water involving considerable risk of ingesting water in quantities suficient to pose a significant health hazard such as swimming and water skiingn (IAG Title 35, Section 301.355).
Conclusions The temperature of the blowdown water discharged from Byron's circulating water system to the Rock River is monitored and reported to the Illinois EPA to verify compliance with the Station's NPDES permit. The size of the discharge thermal plume (mixing zone) is consistent with lllinois EPA regulatory requirements. The circulating water system is treated with biocides, and the sewage treatment plant effluent mixes with the circulating water system blowdown prior to discharge. For these reasons, Exelon Generation concludes that blowdown water discharges from Byron are having little effect on the small risk to public health posed by exposure to thermophilic pathogens possibly present in stream segment lL-P-20 of the Rock River.
Furthermore, because renewal of the Byron Units 1 and 2 operating licenses by NRC will authorize no new construction, refurbishment or operational changes to the circulating water system that would affect thermal characteristics of the discharge, Exelon Generation concludes that the proposed license renewals would not contribute to any increase in adverse effects on public health from exposure to N. fowIeri or any other thermophilic pathogen in the Rock River.
In closing, we wouid appreciate receiving a response from you detailing issues or information that we may have overlooked and that your staff believes could expedite NRC's review of the Byron License Renewal Application. We would also welcome your confirmation of our wnciusions that renewing the Byron operating licenses would not increase adverse effects on public health from exposure to thermophilic pathogens in the Rock River.
Because Exelon Generation will incorporate a copy of your response, as well as this letter, into the environmental report that will be submitted to the NRC as part of the Byron License Renewal Application, your response will be most helpful if we receive it by February 13, 2013.
Please call Nancy Ranek (610) 765-5369, Exelon Generation's License Renewal Environmental Lead, if you have questions or require additional information. Thank you in advance for your assistance.
Michael P. Gallagher Vim President - License Renewal Exelon Generation, LLC Byron and Braidwood Stations, Units 1 and 2 License Renewal Application Page E-3 Byron Station Environmental Report Appendix E - Microbiological Correspondence
Applies to Both Byron & Braidwood P4t CJL,~*;:'I Go-e'ns:
LaUar "asbp:::ck WE!
M P 5 i Clicec2-r I,/
5 2 5 - 5 3 5 W e s t Jefferson Street. S p r ~ n y f r e i d i i i ~ ~ o t s 6276*-03;il w w w idph state r i u s March 3,2013 Mr. Michael P Gallagher Vice President, License Renewal Exelon Nuclear 200 Exelon Way Kemett Square, PA 19348
Dear Mr. Gallagher:
The Illinois Department of Public Health (IDPH) has received your letter requesting that the Office of Health Protection review part of your application for license renewal for Byron Station Units 1 and 2. The Division of Environmental Health has determined that evaluating and commenting on this license renewal application is outside the scope of our mission and that staff do not have the expertise necessary to adequately evaluate the application.
If you have additional health-related questions, please contact Tiffanie Denny, Environmental Toxicologist, at 217-782-5830 or TTY (for hearing impaired use only) 800-547-W.
Sincerely, Ken McCann, MA, LEHP Chief, Division of Environmental Health I@f~"@vildg psfbBtg h~aIfh~
@BE &:@a~#~jfj at o Ij@e printed on recycled paper Byron and Braidwood Stations, Units 1 and 2 License Renewal Application Page E-4 Byron Station Environmental Report Appendix E - Microbiological Correspondence