Request for Approval to Use a Subsequent American Society of Mechanical Engineers (ASME) Code Edition and Addenda for Examination Categories B-L-1 and C-B in the Fourth Inservice Inspection (ISI) Interval
ML13136A134
Person / Time
Site: Surry  
Issue date: 05/01/2013
From: Lane N
Dominion, Virginia Electric & Power Co (VEPCO)
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
13-264
Download: ML13136A134 (5)


Text

VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 May 1, 2013 United States Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001 Serial No.

SPS L1C/CGL Docket No.

License No.13-264 RO 50-280 50-281 DPR-32 DPR-37 VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNITS 1 AND 2 REQUEST FOR APPROVAL TO USE A SUBSEQUENT AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME)

CODE EDITION AND ADDENDA FOR EXAMINATION CATEGORIES B-L-1 AND C-B IN THE FOURTH INSERVICE INSPECTION (151) INTERVAL Pursuant to 10CFR50.55a(g)(4)(iv), Virginia Electric and Power Company (Dominion) requests NRC approval to use a subsequent ASME Code edition and addenda for the ASME Section XI, Examination Categories B-L-1 and C-B, in the fourth lSI interval for Surry Power Station Units 1 and 2.

This request is consistent with NRC Regulatory Issue Summary 2004-12, "Clarification on Use of Later Editions and Addenda to the ASME OM-Code and Section XL" NRC approval of the use of the later Code edition and addenda, as discussed in the Attachment, is requested by September 30, 2013 to support use of the later Code edition and addenda during the Surry Units 1 and 2 refueling outages in Fall 2013 and Spring 2014, respectively.

If you have any questions or require additional information, please contact Mrs. Candee Lovett at (757) 365-2178.

Very truly yours,

(\\R~

N. L. Lane Site Vice President Surry Power Station Attachment -

Request for Approval to Use a Subsequent ASME Code Edition and Addenda for Examination Categories B-L-1 and C-B in the Fourth lSI Interval Commitments made in this letter: None

cc:

U.S. Nuclear Regulatory Commission Region II Marquis One Tower 245 Peachtree Center Ave., NE Suite 1200 Atlanta, Georgia 30303 NRC Senior Resident Inspector Surry Power Station Ms. K. R. Cotton NRC Project Manager U. S. Nuclear Regulatory Commission One White Flint North Mail Stop 0 8G-9A 11555 Rockville Pike Rockville, Maryland 20852 Dr. V. Sreenivas NRC Project Manager U. S. Nuclear Regulatory Commission One White Flint North Mail Stop 0 8G-9A 11555 Rockville Pike Rockville, Maryland 20852 Serial No.: 13-264 Docket No.: 50-280/281 Page 2 of2

Serial No.: 13-264 Docket No.: 50-280/281 ATTACHMENT Request for Approval to Use a Subsequent ASME Code Edition and Addenda for Examination Categories B-L-1 and C-B in the Fourth 151 Interval Surry Power Station Units 1 and 2 Virginia Electric and Power Company (Dominion)

Serial No.: 13-264 Docket No.: 50-280/281 Attachment Page 1 of 2 Request for Approval to Use a SUbsequent American Society of Mechanical Engineers (ASME) Code Edition and Addenda for Examination Categories B-L-1 and C-B in the Fourth Inservice Inspection (lSI) Interval Virginia Electric and Power Company (Dominion) requests NRC approval to use a subsequent ASME Code edition and addenda for the ASME Section XI, Examination Categories B-L-1 and C-B, in the fourth lSI interval for Surry Power Station Units 1 and 2.

This request is consistent with NRC Regulatory Issue Summary 2004-12, "Clarification on Use of Later Editions and Addenda to the ASME OM Code and Section XI."

1. ASME Code Component(s) Affected The affected ASME Section XI components are the Reactor Coolant Pump (RCP) casing welds (B-L-1) and the Residual Heat Removal (RHR) Heat Exchanger Reinforcement Plate Welds to Vessel (C-B).
2. Applicable Code Edition and Requirements The current ASME Section XI Code of record for the fourth lSI interval for Surry Power Station Units 1 and 2 is the 1998 Edition, including 2000 Addenda.
3. Proposed Subsequent Code Edition and Requirements The subsequent Code edition and addenda proposed for the fourth interval of the lSI Program, Examination Categories B-L-1 and C-B, are ASME Section XI, 2007 Edition, including 2008 Addenda. The 2008 Addenda of Section XI has been incorporated into the regulations by reference, as published in the Federal Register on June 21,2011 (76 FR 36232), and became effective July 21,2011.

ASME Category B-L-1 welds were removed in the ASME Section XI, 2007 Edition, 2008 Addenda because experience has not identified any failures in RCP casings.

The requirement for performing these examinations results in unnecessary radiation exposure for non-destructive examination (NDE) personnel.

Flaw Acceptance Standards for Class 2 austenitic Pressure Retaining Welds of Nozzles in Vessels (ASME Category C-B) exists in IWC-3511, of the 2007 Edition, 2008 Addenda, "Standards for Examination Category C-B, Pressure Retaining

Serial No.: 13-264 Docket No.: 50-280/281 Attachment Page 2 of 2 Welds of Nozzles," by referring to Table IWB-3514.2.

Acceptance criteria do not exist for the RHR Heat Exchangers using the current ASME Code Edition and Addenda of record for Surry Units 1 and 2.

.Therefore, Dominion proposes to use the 2007 Edition through the 2008 Addenda for the Category B-L-1 welds and for Paragraph IWC-3511 in its entirety and with all associated references for the RHR Heat Exchanger C-B welds in the fourth lSI interval for Surry Units 1 and 2.

4. Related Requirements For the portion of the subsequent Code edition and addenda to be used, there are no related requirements, modifications, or limitations listed in 10CFR50.55a that apply to Paragraph IWC-3511 or Examination Category H-L-1, which was deleted from the proposed code edition and addenda.
5. Duration of Use of Proposed Subsequent Code Edition and Requirements This request is applicable for the remainder of the fourth 10-year lSI interval for Unit 1, which is scheduled to end December 13,2013 (after the Fall 2013 refueling outage), and for Unit 2, which is scheduled to end May 9, 2014.
6. Precedent Similar approval for use of a subsequent ASME Code edition and addenda for Examination Category B-L-1 was requested by Palo Verde Nuclear Generating Station Units 1, 2, and 3 in a letter, dated 12/29/2011,

Subject:

Request for Approval to Use a Subsequent ASME Code Edition and Addenda for Examination Categories B-L-1, B-M-1, and C-G in the Third lSI Interval. Approval was granted by an NRC letter, dated 9/18/2012,

Subject:

Palo Verde Nuclear Generating Station Units 1, 2, and 3 - Request for Relief to Use a Later Edition of ASME Code,* Section XI, for Examination Categories B-L-1, B-M-1, and C-G (TAC Nos. ME7805, ME7806, and ME7807).