From:

Benson, Michael To:

Rathbun. Howard Cc:

Rudland. David

Subject:

RE: just let me know if i can help with n anna stuff <eom>

Date:

Thursday, April 19, 2012 10:07:00 AM On it.

From: Rathbun, Howard Sent: Thursday, April 19,.2012 9:59 AM To: Benson, Michael Cc: Rudland, David

Subject:

RE: just let me know if i can help with n anna stuff <eom>

Sure. Run David's flaw evaluation spreadsheet with the attached input deck, and change the residual stress to be constant through-wall at 110% of yield stress (assume yield stress for Inconel of 372 MPa). This will be a bounding case. Run for crack growth rate parameters of 0.242, 0.438, 0.654, 0.988, and 1.780, all times 10A_12. Develop a CDF like David did in the attached spreadsheet with sheet entitled "Dave".

This will be a big help.

Thanks, Howard From: Benson, Michael Sent: Thursday, April 19, 2012 8:14 AM To: Rathbun, Howard

Subject:

just let me' know if i can help with n anna stuff <eom>

Michael Benson, PhD U.S. Nuclear Regulatory Commission Materials Engineer - RES/DE/CIB Phone: (301) 251-7492 Email: MichaeLBenson@nrc.gov Office: CSB 5A10 Mail Stop: CSB 5A24m