Response to RAI 13.19 RELAP5 V3.3 Input
ML13128A506
Person / Time
Site: Rhode Island Atomic Energy Commission
Issue date: 03/15/2013
From: Marlone Davis
State of RI, Atomic Energy Comm
To: William Kennedy
Division of Policy and Rulemaking
References
Download: ML13128A506 (33)


Text

=ricase17.i; revised power shapes, neutronic feedbacks

  • outlet T = 123 F = 323.71 K
  • revised core and reactivity feedback
  • D6 for hot channel
  • add orifice coefficients
  • TOP OF CORE OPEN TO POOL
  • 9.29% of flow through shield cooling
  • revised duct and gate sizes
  • 3x5 LEU fueled core - 14 fuel elements with center beryllium trap,
  • Contains heat structures and reactor kinetics with feedback including
  • feedback
  • for the hot channel.
  • 1
  • options 0000100 new transnt 0000101 run
  • 0000101 inp-chk 0000102 si si 0000105 3.0 5.0 20000.

0000120 110010000 0.0 h2o primary

  • 0000201 480. 1.0e-9 0.005 03 100 10000 20000
  • 0000202 100.0 1.0e-9 0.1 03 100 10000 20000
  • 0000202 50. 1.0e-9 0.010 03 200 8000 20000 0000202 500. 1.0e-9 0.010 03 200 8000 20000 0000203 550. 1.0e-9 0.005 03 20 1000 20000 0000204 2000. 1.0e-9 0.25 03 20 1000 20000
  • =====================================================================*
  • minor edit requests
  • =====================================================================*

0000301 httemp 130101511

  • 0000302 httemp 130101211
  • 0000303 httemp 130100911
  • 0000304 httemp 130100711
  • 0000305 httemp 130100511
  • 0000306 rktpow 0
  • reactor power in w 0000307 rkreac 0
  • total reactivity in $

0000308 httemp 130102211

  • 0000309 rkgapow 0
  • decay power 0000310 htrnr 130101500
  • heat flux 0000311 tempf 130010000
  • T(1) 0000312 tempf 130150000
  • T(15) 0000313 tempf 130300000
  • T(30) 0000314 mflowj 130150000
  • W(hot channel) 0000315 mflowj 120150000
  • W(avg channel)

0000316 mflowj 140010000

  • W(reflector) 0000317 mflowj 150010000
  • W(ctl blade) 0000318 mflowj 202000000
  • W(gate out) 0000319 mflowj 180050000
  • W(1/2 in hole) 0000320 mflowj 211050000
  • W(up duct) 0000321 tempf 211050000
  • T(up duct) 0000322 mflowj 145010000
  • W(Be hole) 0000323 httemp 130101811

$=====================================================================$

$ trip expansion cards 20600000 expanded

  • v trip v code parameter rel v code parameter constant l timeoff 20600010 time 0 gt null 0 0.0 n *react inser 20600020 time 0 gt null 0 509. n *outlet gate 20600030 time 0 gt null 0 509. n *inlet gate
  • 20600020 time 0 gt null 0 0. n *outlet gate
  • 20600030 time 0 gt null 0 0. n *inlet gate

$=====================================================================$

  • expanded minor edits

$=====================================================================$

20800001 viscf 110010000 20800002 dt 0 20800003 dtcrnt 0 20800004 flenth 110010000 20800005 flenth 115010000 20800006 flenth 115020000 20800007 hvmix 115010000 20800008 sathf 115010000 20800009 sathg 115010000

$=====================================================================$

  • hydrodynamic components
  • ====================================================================**
  • hydro component name component type 1050000 "inlet" sngljun
  • hydro from to area f loss r loss fvcahs 1050101 190200002 110010001 0. 0.0 0.0 001100
  • hydro jun diam beta intercept slope 1050110 0.0 0.0 1.0 1.0
  • hydro vel/flw f mass flow g mass flow j mass flow 1050201 1 0. 0. 0.
  • mass flow

$======================================================================$

  • hydro component name component type 1100000 "inplenum" branch
  • hydro no. juns vel/flw 1100001 4 1
  • hydro area length volume 1100101 0.0 5.0165e-1 2.4466e-1
  • hydro horz angle vert angle delta z 1100102 0.0 -90.0 -5.0165e-1
  • hydro roughness hyd diam pvbfe 1100103 1.5e-6 0.0 00000
  • hydro ebt pressure temperature 1100200 3 1.71995e+5 318.13
  • hydro from to area f loss r loss fvcahs 1101101 110010000 301000000 0.0 0.0 0.0 001100 1102101 110010000 140000000 0.0 0.0 0.0 001100 1103101 110010000 150000000 0.0 0.0 0.0 001100 1104101 110010000 145000000 0.0 0.0 0.0 001100
  • hydro jun diam beta intercept slope 1101110 0.0 0.0 1.0 1.0 1102110 0.0 0.0 1.0 1.0 1103110 0.0 0.0 1.0 1.0
  • hydro f mass flow g mass flow j mass flow 1101201 0.0 0. 0.

1102201 0.0 0. 0.

1103201 0.0 0. 0.

1104201 0.0 0. 0.

  • ====================================================================**
  • hydro component name component type 1150000 "core in" branch
  • hydro no. juns vel/flw 1150001 3 1
  • hydro area length volume 1150101 0.0 1.8415e-1 9.2223e-3
  • hydro horz angle vert angle delta z 1150102 0.0 -90.0 -1.8415e-1
  • hydro roughness hyd diam pvbfe 1150103 1.5e-6 5.6058e-2 00000
  • hydro ebt pressure temperature 1150200 3 1.75638e+5 318.13
  • hydro from to area f loss r loss fvcahs 1151101 115010000 120000000 0.0 0.0 0.0 001100 1152101 115010000 130000000 0.0 0.0 0.0 001100 1153101 115000000 302000000 0.0 0.0 0.0 001100
  • hydro jun diam beta intercept slope
  • 1151110 0.0 0.0 1.0 1.0
  • 1152110 0.0 0.0 1.0 1.0
  • hydro f mass flow g mass flow j mass flow 1151201 0.0 0. 0.

1152201 0.0 0. 0.

1153201 0.0 0. 0.

$=====================================================================$

  • hydro component name component type 1200000 "avg chan" pipe
  • hydro no. volumes 1200001 30
  • hydro vol area vol 1200101 4.565e-2 30
  • hydro length vol 1200301 3.8947e-2 1 1200302 1.9897e-2 29 1200303 3.8947e-2 30
  • hydro volume vol 1200401 0.0 30
  • hydro vert angle vol 1200601 -90.0 30
  • hydro delta z vol 1200701 -3.8947e-2 1 1200702 -1.9897e-2 29 1200703 -3.8947e-2 30
  • hydro roughness hyd diam vol 1200801 1.5e-6 4.47e-3 30
  • f loss r loss jun 1200901.25 0.05 1 1200902 0.0 0.0 28 1200903 0.05.25 29
  • hydro pvbfe vol 1201001 00200 30
  • hydro fvcahs jun 1201101 001000 29
  • hydro ebt pressure temperature vol 1201201 3 1.76313e+5 318.13 0. 0. 0. 1 1201202 3 1.76297e+5 318.13 0. 0. 0. 2 1201203 3 1.76286e+5 318.13 0. 0. 0. 3 1201204 3 1.76275e+5 318.13 0. 0. 0. 4 1201205 3 1.76264e+5 318.13 0. 0. 0. 5 1201206 3 1.76252e+5 318.13 0. 0. 0. 6 1201207 3 1.76241e+5 318.13 0. 0. 0. 7 1201208 3 1.76230e+5 318.13 0. 0. 0. 8 1201209 3 1.76219e+5 318.13 0. 0. 0. 9 1201210 3 1.76208e+5 318.13 0. 0. 0. 10 1201211 3 1.76197e+5 318.13 0. 0. 0. 11 1201212 3 1.76186e+5 318.13 0. 0. 0. 12 1201213 3 1.76174e+5 318.13 0. 0. 0. 13 1201214 3 1.76163e+5 318.13 0. 0. 0. 14 1201215 3 1.76152e+5 318.13 0. 0. 0. 15 1201216 3 1.76141e+5 318.13 0. 0. 0. 16 1201217 3 1.76130e+5 318.13 0. 0. 0. 17 1201218 3 1.76119e+5 318.13 0. 0. 0. 18 1201219 3 1.76108e+5 318.13 0. 0. 0. 19

1201220 3 1.76096e+5 318.13 0. 0. 0. 20 1201221 3 1.76085e+5 318.13 0. 0. 0. 21 1201222 3 1.76074e+5 318.13 0. 0. 0. 22 1201223 3 1.76063e+5 318.13 0. 0. 0. 23 1201224 3 1.76052e+5 318.13 0. 0. 0. 24 1201225 3 1.76041e+5 318.13 0. 0. 0. 25 1201226 3 1.76030e+5 318.13 0. 0. 0. 26 1201227 3 1.76019e+5 318.13 0. 0. 0. 27 1201228 3 1.76007e+5 318.13 0. 0. 0. 28 1201229 3 1.75996e+5 318.13 0. 0. 0. 29 1201230 3 1.75980e+5 318.13 0. 0. 0. 30

  • hydro vel/flow 1201300 1
  • hydro f mass flow g mass flow j mass flow jun 1201301 0.00 0. 0. 1 1201302 0.00 0. 0. 2 1201303 0.00 0. 0. 3 1201304 0.00 0. 0. 4 1201305 0.00 0. 0. 5 1201306 0.00 0. 0. 6 1201307 0.00 0. 0. 7 1201308 0.00 0. 0. 8 1201309 0.00 0. 0. 9 1201310 0.00 0. 0. 10 1201311 0.00 0. 0. 11 1201312 0.00 0. 0. 12 1201313 0.00 0. 0. 13 1201314 0.00 0. 0. 14 1201315 0.00 0. 0. 15 1201316 0.00 0. 0. 16 1201317 0.00 0. 0. 17 1201318 0.00 0. 0. 18 1201319 0.00 0. 0. 19 1201320 0.00 0. 0. 20 1201321 0.00 0. 0. 21 1201322 0.00 0. 0. 22 1201323 0.00 0. 0. 23 1201324 0.00 0. 0. 24 1201325 0.00 0. 0. 25 1201326 0.00 0. 0. 26 1201327 0.00 0. 0. 27 1201328 0.00 0. 0. 28 1201329 0.00 0. 0. 29
  • hydro jun diam beta intercept slope jun 1201401 4.3415e-3 0.0 1.0 1.0 29
  • hydro x-shpfac x-visc y-shpfac y-visc z-shpfac z-visc vol 1202501 0.6667 0.14 1.0 0.14 1.0 0.14 30
  • hydro a b c vol 1202601 0. 0.046 0.2 0. 0. 0. 0. 0. 0. 30
  • hydro pitch span vol 1203101 2.032e-3 6.7793e-2 30

$=====================================================================$

  • hydro component name component type 1300000 "hot chan" pipe
  • hydro no. volumes 1300001 30
  • hydro vol area vol 1300101 1.487e-4 30
  • minimum based on tolerances
  • hydro length vol 1300301 3.8947e-2 1 1300302 1.9897e-2 29 1300303 3.8947e-2 30
  • hydro volume vol 1300401 0.0 30
  • hydro vert angle vol 1300601 -90.0 30
  • hydro delta z vol 1300701 -3.8947e-2 1 1300702 -1.9897e-2 29 1300703 -3.8947e-2 30
  • hydro roughness hyd diam vol 1300801 1.5e-6 4.47e-3 30
  • minimum based on tolerances
  • f loss r loss jun 1300901 0.25 0.05 1 1300902 0.0 0.0 28 1300903 0.05 0.25 29
  • hydro pvbfe vol 1301001 00200 30
  • hydro fvcahs jun 1301101 001000 29
  • hydro ebt pressure temperature vol 1301201 3 1.76438e+5 318.130 0. 0. 0. 1 1301202 3 1.76421e+5 318.130 0. 0. 0. 2 1301203 3 1.76410e+5 318.130 0. 0. 0. 3 1301204 3 1.76398e+5 318.131 0. 0. 0. 4 1301205 3 1.76387e+5 318.131 0. 0. 0. 5 1301206 3 1.76375e+5 318.131 0. 0. 0. 6 1301207 3 1.76364e+5 318.131 0. 0. 0. 7 1301208 3 1.76352e+5 318.131 0. 0. 0. 8 1301209 3 1.76341e+5 318.131 0. 0. 0. 9 1301210 3 1.76329e+5 318.132 0. 0. 0. 10 1301211 3 1.76318e+5 318.132 0. 0. 0. 11 1301212 3 1.76306e+5 318.132 0. 0. 0. 12 1301213 3 1.76295e+5 318.132 0. 0. 0. 13

1301214 3 1.76283e+5 318.133 0. 0. 0. 14 1301215 3 1.76272e+5 318.133 0. 0. 0. 15 1301216 3 1.76261e+5 318.133 0. 0. 0. 16 1301217 3 1.76249e+5 318.134 0. 0. 0. 17 1301218 3 1.76238e+5 318.135 0. 0. 0. 18 1301219 3 1.76226e+5 318.135 0. 0. 0. 19 1301220 3 1.76215e+5 318.136 0. 0. 0. 20 1301221 3 1.76203e+5 318.137 0. 0. 0. 21 1301222 3 1.76192e+5 318.137 0. 0. 0. 22 1301223 3 1.76180e+5 318.138 0. 0. 0. 23 1301224 3 1.76169e+5 318.138 0. 0. 0. 24 1301225 3 1.76157e+5 318.139 0. 0. 0. 25 1301226 3 1.76146e+5 318.139 0. 0. 0. 26 1301227 3 1.76134e+5 318.139 0. 0. 0. 27 1301228 3 1.76123e+5 318.130 0. 0. 0. 28 1301229 3 1.76111e+5 318.130 0. 0. 0. 29 1301230 3 1.76094e+5 318.130 0. 0. 0. 30

  • hydro vel/flow 1301300 1
  • hydro f mass flow g mass flow j mass flow jun 1301301 0.00 0. 0. 1 1301302 0.00 0. 0. 2 1301303 0.00 0. 0. 3 1301304 0.00 0. 0. 4 1301305 0.00 0. 0. 5 1301306 0.00 0. 0. 6 1301307 0.00 0. 0. 7 1301308 0.00 0. 0. 8 1301309 0.00 0. 0. 9 1301310 0.00 0. 0. 10 1301311 0.00 0. 0. 11 1301312 0.00 0. 0. 12 1301313 0.00 0. 0. 13 1301314 0.00 0. 0. 14 1301315 0.00 0. 0. 15 1301316 0.00 0. 0. 16 1301317 0.00 0. 0. 17 1301318 0.00 0. 0. 18 1301319 0.00 0. 0. 19 1301320 0.00 0. 0. 20 1301321 0.00 0. 0. 21 1301322 0.00 0. 0. 22 1301323 0.00 0. 0. 23 1301324 0.00 0. 0. 24 1301325 0.00 0. 0. 25 1301326 0.00 0. 0. 26 1301327 0.00 0. 0. 27 1301328 0.00 0. 0. 28 1301329 0.00 0. 0. 29
  • hydro jun diam beta intercept slope jun 1301401 4.0415e-3 0.0 1.0 1.0 29
  • hydro x-shpfac x-visc y-shpfac y-visc z-shpfac z-visc vol 1302501 0.6667 0.14 1.0 0.14 1.0 0.14 30
  • hydro a b c vol 1302601 0. 0.046 0.2 0. 0. 0. 0. 0. 0. 30
  • hydro pitch span vol 1303101 2.0828e-3 6.7793e-2 30

$=====================================================================$

  • hydro component name component type 1400000 "reflectr" pipe
  • graphite
  • hydro no. volumes 1400001 8
  • hydro vol area vol 1400101.221 1 1400102.00344 2 1400103.00518 6 1400104.00344 7 1400105.221 8
  • hydro length vol 1400301.12065 1 1400302.03175 2 1400303.17463 6 1400304.03175 7 1400305.12065 8
  • hydro volume vol 1400401 0. 8
  • hydro vert angle vol 1400601 -90.0 8
  • hydro delta z vol 1400701 -.12065 1 1400702 -.03175 2 1400703 -.17463 6 1400704 -.03175 7 1400705 -.12065 8
  • hydro roughness hyd diam vol 1400801 1.5e-6.1 1 1400802 1.5e-6.00191 2 1400803 1.5e-6.00290 6 1400804 1.5e-6.00191 7 1400805 1.5e-6.1 8
  • f loss r loss jun 1400901 0.0 0.0 1 1400902 0.6 1.0 2 1400903 0.0 0.0 5 1400904 1.0 0.6 6 1400905 0.0 0.0 7
  • hydro pvbfe vol 1401001 00200 8
  • hydro fvcahs jun 1401101 001000 7
  • hydro ebt pressure tempe vol 1401201 3 1.77316e+5 318.130 0. 0. 0. 1 1401202 3 1.73434e+5 318.130 0. 0. 0. 2 1401203 3 1.73130e+5 318.131 0. 0. 0. 3 1401204 3 1.72853e+5 318.131 0. 0. 0. 4 1401205 3 1.72575e+5 318.131 0. 0. 0. 5 1401206 3 1.72298e+5 318.132 0. 0. 0. 6 1401207 3 1.71994e+5 318.132 0. 0. 0. 7 1401208 3 1.77258e+5 318.132 0. 0. 0. 8
  • hydro vel/flow 1401300 1
  • hydro f mass flow g mass flow j mass flow jun 1401301 0.00 0. 0. 1 1401302 0.00 0. 0. 2 1401303 0.00 0. 0. 3 1401304 0.00 0. 0. 4 1401305 0.00 0. 0. 5 1401306 0.00 0. 0. 6 1401307 0.00 0. 0. 7
  • hydro jun diam beta intercept slope jun 1401401 0.0 0.0 1.0 1.0 7
  • hydro x-shpfac x-visc y-shpfac y-visc z-shpfac z-visc vol 1402501 0.6667 0.14 1.0 0.14 1.0 0.14 8
  • hydro a b c vol 1402601 0. 0.046 0.2 0. 0. 0. 0. 0. 0. 8
  • hydro pitch span vol 1403101 2.0828e-3 6.7793e-2 8

$=====================================================================$

  • hydro component name component type 1450000 BeHole pipe
  • Be 1/4" hole
  • hydro no. volumes 1450001 8
  • hydro vol area vol 1450101.154 1 1450102.000507 7 1450103.154 8
  • hydro length vol 1450301.12065 1 1450302.127 7 1450303.12065 8
  • hydro volume vol 1450401 0. 8
  • hydro vert angle vol 1450601 -90.0 8
  • hydro delta z vol 1450701 -.12065 1 1450702 -.127 7 1450703 -.12065 8
  • hydro roughness hyd diam vol 1450801 1.5e-6.1 1 1450802 1.5e-6.00635 7 1450805 1.5e-6.1 8
  • f loss r loss jun 1450901 0.0 0.0 1 1450902 0.6 1.0 2 1450903 0.0 0.0 5 1450904 1.0 0.6 6 1450905 0.0 0.0 7
  • hydro pvbfe vol 1451001 00000 8
  • hydro fvcahs jun 1451101 001000 7
  • hydro ebt pressure tempe vol 1451201 3 1.77316e+5 318.130 0. 0. 0. 1 1451202 3 1.73434e+5 318.130 0. 0. 0. 2 1451203 3 1.73130e+5 318.131 0. 0. 0. 3 1451204 3 1.72853e+5 318.131 0. 0. 0. 4 1451205 3 1.72575e+5 318.131 0. 0. 0. 5 1451206 3 1.72298e+5 318.132 0. 0. 0. 6 1451207 3 1.71994e+5 318.132 0. 0. 0. 7 1451208 3 1.77258e+5 318.132 0. 0. 0. 8
  • hydro vel/flow 1451300 1
  • hydro f mass flow g mass flow j mass flow jun 1451301 0.00 0. 0. 1 1451302 0.00 0. 0. 2 1451303 0.00 0. 0. 3 1451304 0.00 0. 0. 4 1451305 0.00 0. 0. 5 1451306 0.00 0. 0. 6 1451307 0.00 0. 0. 7
  • hydro jun diam beta intercept slope jun 1451401 0.0 0.0 1.0 1.0 7
  • hydro x-shpfac x-visc y-shpfac y-visc z-shpfac z-visc vol 1452501 0.6667 0.14 1.0 0.14 1.0 0.14 8
  • hydro a b c vol 1452601 0. 0.046 0.2 0. 0. 0. 0. 0. 0. 8

$=====================================================================$

  • hydro component name component type 1500000 "ctrblade" pipe
  • hydro no. volumes 1500001 8
  • hydro vol area vol 1500101.01044 7 1500102.02075 8
  • hydro length vol 1500301.139045 7 1500302.03 8
  • hydro volume vol 1500401 0.0 8
  • hydro vert angle vol 1500601 -90.0 8
  • hydro delta z vol 1500701 -.139045 7 1500702 -.03 8
  • hydro roughness hyd diam vol 1500801 1.5e-6.009136 4 1500802 1.5e-6.03561 8
  • f loss r loss jun 1500901.35.25 1 1500902 0.0 0.0 3 1500903.25.35 4 1500904 0.0 0.0 7
  • hydro pvbfe vol 1501001 00000 8
  • hydro fvcahs jun 1501101 001000 7
  • hydro ebt pressure temperature vol 1501201 3 1.77329e+5 318.130 0. 0. 0. 1 1501202 3 1.78799e+5 318.130 0. 0. 0. 2 1501203 3 1.79858e+5 318.130 0. 0. 0. 3 1501204 3 1.80824e+5 318.130 0. 0. 0. 4 1501205 3 1.81790e+5 318.130 0. 0. 0. 5 1501206 3 1.82756e+5 318.130 0. 0. 0. 6 1501207 3 1.83815e+5 318.130 0. 0. 0. 7 1501208 3 1.85285e+5 318.130 0. 0. 0. 8
  • hydro vel/flow 1501300 1
  • hydro f mass flow g mass flow j mass flow jun 1501301 0.0 0. 0. 1 1501302 0.0 0. 0. 2

1501303 0.0 0. 0. 3 1501304 0.0 0. 0. 4 1501305 0.0 0. 0. 5 1501306 0.0 0. 0. 6 1501307 0.0 0. 0. 7

  • hydro jun diam beta intercept slope jun 1501401 1.0837e-2 0.0 1.0 1.0 1 1501402 2.3902e-2 0.0 1.0 1.0 7
  • hydro x-shpfac x-visc y-shpfac y-visc z-shpfac z-visc vol
  • 1502501 0.6667 0.14 1.0 0.14 1.0 0.14 8
  • hydro a b c vol
  • 1502601 0. 0.046 0.2 0. 0. 0. 0. 0. 0. 8
  • ====================================================================**
  • hydro component name component type 1700000 "fuel out" branch
  • hydro no. juns vel/flw 1700001 2 1
  • hydro area length volume 1700101 0.0 1.8415e-1 9.2223e-3
  • hydro horz angle vert angle delta z 1700102 0.0 -90.0 -1.8415e-1
  • hydro roughness hyd diam pvbfe 1700103 1.5e-6 5.6058e-2 00000
  • hydro ebt pressure temperature 1700200 3 1.76980e+5 318.138
  • hydro from to area f loss r loss fvcahs 1701101 120010000 170000000 0.0 0.0 0.0 001100 1702101 130010000 170000000 0.0 0.0 0.0 001100
  • hydro jun diam beta intercept slope 1701110 4.3415e-3 0.0 1.0 1.0 1702110 4.0415e-3 0.0 1.0 1.0
  • hydro f mass flow g mass flow j mass flow 1701201 0.0 0. 0.

1702201 0.0 0. 0.

  • ====================================================================**
  • This volume mirrors component volume 110
  • hydro component name component type 1800000 "outplnm" branch
  • hydro no. juns vel/flw 1800001 6 1
  • hydro area length volume 1800101 0.000 5.0165e-1 3.9691e-1
  • hydro horz angle vert angle delta z 1800102 0.0 -90.0 -5.0165e-1
  • hydro roughness hyd diam pvbfe 1800103 1.5e-6 0.0 00000
  • hydro ebt pressure temperature 1800200 3 1.82594e+5 318.137
  • hydro from to area f loss r loss fvcahs 1801101 170010000 180000000 0.0 0.0 0.0 001100 1802101 140010000 180000000 0.0 0.0 0.0 001100 1803101 150010000 180000000.00253 1.15 1.05 001000 1804101 180000000 211010001 0. 0. 0. 001000 1805101 180010000 212010001 1.27e-4 1.64 1.64 001000 1806101 145010000 180000000 0.0 0.0 0.0 001100
  • hydro f mass flow g mass flow j mass flow 1801201 0. 0. 0.

1802201 0. 0. 0.

1803201 0. 0. 0.

1804201 0. 0. 0.

1805201 0. 0. 0.

1806201 0. 0. 0.

  • ====================================================================**
  • hydro component name component type 1900000 pipedn pipe
  • hydro no. volumes 1900001 20
  • hydro vol area vol 1900101.1142 20
  • hydro length vol 1900301.10285 20
  • hydro volume vol 1900401 0.0 20
  • hydro vert angle vol 1900601 -90.0 20
  • hydro delta z vol 1900701 -.10285 20
  • hydro roughness hyd diam vol 1900801 1.5e-6.253 20
  • f loss r loss jun 1900901 0.0 0.0 19
  • hydro pvbfe vol 1901001 00000 20
  • hydro fvcahs jun 1901101 001000 19
  • hydro ebt pressure temperature vol 1901201 3 1.5e5 318.13 0. 0. 0. 20
  • hydro vel/flow 1901300 1
  • hydro f mass flow g mass flow j mass flow jun 1901301 0. 0. 0. 19
  • hydro x-shpfac x-visc y-shpfac y-visc z-shpfac z-visc vol 1902501 0.6667 0.14 1.0 0.14 1.0 0.14 20

$=====================================================================$

  • hydro component name component type 2000000 dn_loop sngljun
  • hydro from to area f loss r loss fvcahs 2000101 201010002 190010001.1142 0.0 0.0 001100
  • hydro vel/flw f mass flow g mass flow j mass flow 2000201 1 0. 0. 0.
  • mass flow

$=====================================================================$

  • hydro component name component type 2010000 gate_lop snglvol
  • hydro Ac L vol az an inclin dz roughness Dh tlpvbfe 2010101.1142.61 0. 0. -90. -.61 1.0e-6.253 0000000
  • hydro ebt p T 2010200 003 1.4263e5 318.13

$=====================================================================$

  • hydro component name component type 2020000 gate_out valve
  • hydro from to area f loss r loss fvcahs 2020101 201010002 203010001.0355 1.64 1.64 001100
  • hydro vel/flw f mass flow g mass flow j mass flow 2020201 1 0. 0. 0.
  • mass flow
  • hydro valve type 2020300 trpvlv
  • hydro trip number 2020301 2
  • ====================================================================**
  • hydro component name component type 2030000 poolout tmdpvol
  • hydro area length volume 2030101 1.0234e-1 0.0 1.0e6
  • hydro horz angle vert angle delta z 2030102.0 0.0 0.0
  • hydro roughness hyd diam fe 2030103.0.0 10
  • hydro ebt trip no. alpha vrc numeric vrc 2030200 003
  • hydro time pressure temperature 2030201 0. 144632.7 318.13

$======================================================================$

  • hydro component name component type 2040000 pump tmdpjun
  • hydro from to area 2040101 205200002 201010001.00456
  • hydro vel/flw trip no. alpha vrc numeric vrc 2040200 1
  • hydro time f flowrate g flowrate j flowrate 2040201 0.0 0. 0. 0
  • 0 gpm 2040202 1.0 98.6 0. 0
  • 1740 gpm x

.9071

  • 1740 gpm x.9071 = 98.60 KG/s
  • 1580 gpm x.9071 = 89.51 KG/s
  • W = 89.51 at t = 500.103 s 2040203 500.0000 98.600 0. 0.

2040204 500.2044 80.628 0. 0.

2040205 500.3544 67.436 0. 0.

2040206 500.5744 55.235 0. 0.

2040207 500.7744 44.676 0. 0.

2040208 500.9144 35.932 0. 0.

2040209 500.9144 35.932 0. 0.

2040210 501.1544 30.815 0. 0.

2040211 501.3644 22.771 0. 0.

2040212 501.7144 16.941 0. 0.

2040213 502.2144 11.323 0. 0.

2040214 502.9144 7.814 0. 0.

2040215 503.4344 5.752 0. 0.

2040216 504.0444 4.003 0. 0.

2040217 504.4544 3.182 0. 0.

2040218 505.1444 2.308 0. 0.

2040219 506.4544 1.374 0. 0.

2040220 507.9944 0.945 0. 0.

2040221 508.9544 0.599 0. 0.

2040222 509.9644 0.358 0. 0.

2040223 510.9444 0.192 0. 0.

2040224 512.9544 0.039 0. 0.

2040225 514. 0.0 0. 0.

2040226 10000. 0.0 0. 0.

$=====================================================================$

  • hydro component name component type

2050000 loop pipe

  • hydro no. volumes 2050001 20
  • hydro vol area vol
  • 2050101.00456 20
  • 2050101.00912 20 2050101.04 20
  • hydro length vol 2050301.5 20
  • hydro volume vol 2050401 0.0 20
  • hydro vert angle vol 2050601 0. 20
  • hydro delta z vol 2050701 0. 20
  • hydro roughness hyd diam vol
  • 2050801 1.5e-6.0762 20 2050801 1.5e-6.1524 20 2050801 1.5e-6.30 20
  • f loss r loss jun 2050901 0.0 0.0 19
  • hydro pvbfe vol 2051001 00000 20
  • hydro fvcahs jun 2051101 001000 19
  • hydro ebt pressure temperature vol 2051201 3 142630. 318.13 0. 0. 0. 20
  • hydro vel/flow 2051300 1
  • hydro f mass flow g mass flow j mass flow jun 2051301 0. 0. 0. 19
  • hydro x-shpfac x-visc y-shpfac y-visc z-shpfac z-visc vol 2052501 1.0 0.14 1.0 0.14 1.0 0.14 20

$=====================================================================$

  • hydro component name component type 2060000 loop_up sngljun
  • hydro from to area f loss r loss fvcahs 2060101 207010002 205010001.00 0.0 0.0 001100
  • hydro vel/flw f mass flow g mass flow j mass flow 2060201 1 0. 0. 0.
  • mass flow

$=====================================================================$

  • hydro component name component type 2070000 gate2_lp snglvol
  • hydro Ac L vol az an inclin dz roughness Dh tlpvbfe 2070101.1142.61 0. 0. 90..61 1.0e-6.253 0000000
  • hydro ebt p T 2070200 003 1.4263e5 318.13

$=====================================================================$

  • hydro component name component type 2080000 gate_in valve
  • hydro from to area f loss r loss fvcahs 2080101 207010001 209010001.0355 1.64 1.64 001100
  • hydro vel/flw f mass flow g mass flow j mass flow 2080201 1 0. 0. 0.
  • mass flow
  • hydro valve type 2080300 trpvlv
  • hydro trip number 2080301 3
  • ====================================================================**
  • hydro component name component type 2090000 poolin tmdpvol
  • hydro area length volume 2090101 1.0234e-1 0.0 1.0e6
  • hydro horz angle vert angle delta z 2090102.0 0.0 0.0
  • hydro roughness hyd diam fe 2090103.0.0 10
  • hydro ebt trip no. alpha vrc numeric vrc 2090200 003
  • hydro time pressure temperature 2090201 0. 144632.7 318.13

$=====================================================================$

  • hydro component name component type 2100000 up_chnl sngljun
  • hydro from to area f loss r loss fvcahs 2100101 211200002 207010001.1142 0.0 0.0 001100
  • hydro vel/flw f mass flow g mass flow j mass flow 2100201 1 0. 0. 0.
  • mass flow
  • ====================================================================**
  • hydro component name component type 2110000 pipeup pipe
  • hydro no. volumes 2110001 20
  • hydro vol area vol 2110101.1142 20
  • hydro length vol 2110301.178098 20
  • hydro volume vol 2110401 0.0 20
  • hydro vert angle vol 2110601 90.0 20
  • hydro delta z vol 2110701.178098 20
  • hydro roughness hyd diam vol 2110801 1.5e-6.253 20
  • f loss r loss jun 2110901 0.0 0.0 19
  • hydro pvbfe vol 2111001 00000 20
  • hydro fvcahs jun 2111101 001000 19
  • hydro ebt pressure temperature vol 2111201 3 1.5e5 318.13 0. 0. 0. 20
  • hydro vel/flow 2111300 1
  • hydro f mass flow g mass flow j mass flow jun 2111301 0. 0. 0. 19
  • hydro x-shpfac x-visc y-shpfac y-visc z-shpfac z-visc vol 2112501 0.6667 0.14 1.0 0.14 1.0 0.14 20
  • ====================================================================**
  • hydro component name component type 2120000 hole tmdpvol
  • hydro area length volume 2120101 1.0234e-1 0.0 1.0e6
  • hydro horz angle vert angle delta z 2120102.0 0.0 0.0
  • hydro roughness hyd diam fe 2120103.0.0 10
  • hydro ebt trip no. alpha vrc numeric vrc 2120200 003
  • hydro time pressure temperature 2120201 0. 184094.5 318.13
  • ====================================================================**
  • hydro component name component type 3010000 poolrf tmdpvol
  • hydro area length volume 3010101 1.0 0.0 1.0e6
  • hydro horz angle vert angle delta z 3010102.0 0.0 0.0
  • hydro roughness hyd diam fe 3010103.0.0 10
  • hydro ebt trip no. alpha vrc numeric vrc 3010200 003
  • hydro time pressure temperature 3010201 0. 169479.7 318.13
  • ====================================================================**
  • hydro component name component type 3020000 poolcr tmdpvol
  • hydro area length volume 3020101 1.0 0.0 1.0e6
  • hydro horz angle vert angle delta z 3020102.0 0.0 0.0
  • hydro roughness hyd diam fe 3020103.0.0 10
  • hydro ebt trip no. alpha vrc numeric vrc 3020200 003
  • hydro time pressure temperature 3020201 0. 169479.7 318.13
  • ====================================================================**
  • hydro component name component type 4010000 poolup pipe
  • hydro no. volumes 4010001 20
  • hydro vol area vol 4010101 10. 20
  • hydro length vol 4010301.178098 20
  • hydro volume vol 4010401 0.0 20
  • hydro vert angle vol 4010601 90.0 20
  • hydro delta z vol 4010701.178098 20
  • hydro roughness hyd diam vol 4010801 1.5e-6 3. 20
  • f loss r loss jun 4010901 0.0 0.0 19
  • hydro pvbfe vol 4011001 00000 20
  • hydro fvcahs jun 4011101 001000 19
  • hydro ebt pressure temperature vol 4011201 3 1.5e5 318.13 0. 0. 0. 20
  • hydro vel/flow 4011300 1
  • hydro f mass flow g mass flow j mass flow jun 4011301 0. 0. 0. 19
  • hydro x-shpfac x-visc y-shpfac y-visc z-shpfac z-visc vol 4012501 0.6667 0.14 1.0 0.14 1.0 0.14 20

$=====================================================================$

  • hydro component name component type 4020000 pooljnl sngljun
  • hydro from to area f loss r loss fvcahs 4020101 401010001 211010001.01 0.0 0.0 001100
  • hydro vel/flw f mass flow g mass flow j mass flow 4020201 1 0. 0. 0.
  • mass flow

$======================================================================$

  • heat structures

$======================================================================$

$ ht str no. 120-1 average fuel plate $

  • htstr ht strs m pts geom init l.coord refl b.vol axl. incr 11201000 30 11 1 0 0.0
  • htstr mesh locn mesh fmt 11201100 0 1
  • htstr intervals rt. coord 11201101 2 3.810e-4

11201102 8 6.350e-4

  • htstr compxn no. interval 11201201 -2 2 11201202 1 10
  • htstr source interval 11201301 0.0 2 11201302 1.0 10
  • htstr temp mesh pt.

11201401 318.13 11

  • htstr left vol incr b.cond sa code area/factor ht str no.

11201501 120010000 10000 102 0 0.8173 30

  • htstr right vol incr b.cond sa code area/factor ht str no.

11201601 0 0 0 0 0.8173 30

  • htstr s. type s. mult left heat right heat ht str no.

11201701 1000 1.81575e-02 0.0 0.0 1 11201702 1000 1.54229e-02 0.0 0.0 2 11201703 1000 1.66062e-02 0.0 0.0 3 11201704 1000 1.82967e-02 0.0 0.0 4 11201705 1000 2.02954e-02 0.0 0.0 5 11201706 1000 2.25129e-02 0.0 0.0 6 11201707 1000 2.47602e-02 0.0 0.0 7 11201708 1000 2.65501e-02 0.0 0.0 8 11201709 1000 2.83300e-02 0.0 0.0 9 11201710 1000 3.04182e-02 0.0 0.0 10 11201711 1000 3.24865e-02 0.0 0.0 11 11201712 1000 3.44952e-02 0.0 0.0 12 11201713 1000 3.64442e-02 0.0 0.0 13 11201714 1000 3.82838e-02 0.0 0.0 14 11201715 1000 3.99742e-02 0.0 0.0 15 11201716 1000 4.14758e-02 0.0 0.0 16 11201717 1000 4.26988e-02 0.0 0.0 17 11201718 1000 4.36932e-02 0.0 0.0 18 11201719 1000 4.41805e-02 0.0 0.0 19 11201720 1000 4.44291e-02 0.0 0.0 20 11201721 1000 4.39418e-02 0.0 0.0 21 11201722 1000 4.32656e-02 0.0 0.0 22 11201723 1000 4.23707e-02 0.0 0.0 23 11201724 1000 4.13564e-02 0.0 0.0 24 11201725 1000 3.90196e-02 0.0 0.0 25 11201726 1000 3.66232e-02 0.0 0.0 26 11201727 1000 3.39483e-02 0.0 0.0 27 11201728 1000 3.19496e-02 0.0 0.0 28 11201729 1000 3.14524e-02 0.0 0.0 29 11201730 1000 3.09452e-02 0.0 0.0 30

  • htstr heat diam h len-f h len-r glf glr k-f k-r f ht str no.

11201801 4.47e-3 0.00995 0.58705 0.0 0.0 0.0 0.0 1.0 1 11201802 4.47e-3 0.02985 0.56715 0.0 0.0 0.0 0.0 1.0 2 11201803 4.47e-3 0.04975 0.54725 0.0 0.0 0.0 0.0 1.0 3 11201804 4.47e-3 0.06965 0.52735 0.0 0.0 0.0 0.0 1.0 4 11201805 4.47e-3 0.08955 0.50745 0.0 0.0 0.0 0.0 1.0 5

11201806 4.47e-3 0.10945 0.48755 0.0 0.0 0.0 0.0 1.0 6 11201807 4.47e-3 0.12935 0.46765 0.0 0.0 0.0 0.0 1.0 7 11201808 4.47e-3 0.14925 0.44775 0.0 0.0 0.0 0.0 1.0 8 11201809 4.47e-3 0.16915 0.42785 0.0 0.0 0.0 0.0 1.0 9 11201810 4.47e-3 0.18905 0.40795 0.0 0.0 0.0 0.0 1.0 10 11201811 4.47e-3 0.20895 0.38805 0.0 0.0 0.0 0.0 1.0 11 11201812 4.47e-3 0.22885 0.36815 0.0 0.0 0.0 0.0 1.0 12 11201813 4.47e-3 0.24875 0.34825 0.0 0.0 0.0 0.0 1.0 13 11201814 4.47e-3 0.26865 0.32835 0.0 0.0 0.0 0.0 1.0 14 11201815 4.47e-3 0.28855 0.30845 0.0 0.0 0.0 0.0 1.0 15 11201816 4.47e-3 0.30845 0.28855 0.0 0.0 0.0 0.0 1.0 16 11201817 4.47e-3 0.32835 0.26865 0.0 0.0 0.0 0.0 1.0 17 11201818 4.47e-3 0.34825 0.24875 0.0 0.0 0.0 0.0 1.0 18 11201819 4.47e-3 0.36815 0.22885 0.0 0.0 0.0 0.0 1.0 19 11201820 4.47e-3 0.38805 0.20895 0.0 0.0 0.0 0.0 1.0 20 11201821 4.47e-3 0.40795 0.18905 0.0 0.0 0.0 0.0 1.0 21 11201822 4.47e-3 0.42785 0.16915 0.0 0.0 0.0 0.0 1.0 22 11201823 4.47e-3 0.44775 0.14925 0.0 0.0 0.0 0.0 1.0 23 11201824 4.47e-3 0.46765 0.12935 0.0 0.0 0.0 0.0 1.0 24 11201825 4.47e-3 0.48755 0.10945 0.0 0.0 0.0 0.0 1.0 25 11201826 4.47e-3 0.50745 0.08955 0.0 0.0 0.0 0.0 1.0 26 11201827 4.47e-3 0.52735 0.06965 0.0 0.0 0.0 0.0 1.0 27 11201828 4.47e-3 0.54725 0.04975 0.0 0.0 0.0 0.0 1.0 28 11201829 4.47e-3 0.56715 0.02985 0.0 0.0 0.0 0.0 1.0 29 11201830 4.47e-3 0.58705 0.00995 0.0 0.0 0.0 0.0 1.0 30

  • htstr heat diam h len-f h len-r glf glr k-f k-r f ht str no.

11201901 0.0 0.00995 0.58705 0.0 0.0 0.0 0.0 1.0 1 11201902 0.0 0.02985 0.56715 0.0 0.0 0.0 0.0 1.0 2 11201903 0.0 0.04975 0.54725 0.0 0.0 0.0 0.0 1.0 3 11201904 0.0 0.06965 0.52735 0.0 0.0 0.0 0.0 1.0 4 11201905 0.0 0.08955 0.50745 0.0 0.0 0.0 0.0 1.0 5 11201906 0.0 0.10945 0.48755 0.0 0.0 0.0 0.0 1.0 6 11201907 0.0 0.12935 0.46765 0.0 0.0 0.0 0.0 1.0 7 11201908 0.0 0.14925 0.44775 0.0 0.0 0.0 0.0 1.0 8 11201909 0.0 0.16915 0.42785 0.0 0.0 0.0 0.0 1.0 9 11201910 0.0 0.18905 0.40795 0.0 0.0 0.0 0.0 1.0 10 11201911 0.0 0.20895 0.38805 0.0 0.0 0.0 0.0 1.0 11 11201912 0.0 0.22885 0.36815 0.0 0.0 0.0 0.0 1.0 12 11201913 0.0 0.24875 0.34825 0.0 0.0 0.0 0.0 1.0 13 11201914 0.0 0.26865 0.32835 0.0 0.0 0.0 0.0 1.0 14 11201915 0.0 0.28855 0.30845 0.0 0.0 0.0 0.0 1.0 15 11201916 0.0 0.30845 0.28855 0.0 0.0 0.0 0.0 1.0 16 11201917 0.0 0.32835 0.26865 0.0 0.0 0.0 0.0 1.0 17 11201918 0.0 0.34825 0.24875 0.0 0.0 0.0 0.0 1.0 18 11201919 0.0 0.36815 0.22885 0.0 0.0 0.0 0.0 1.0 19 11201920 0.0 0.38805 0.20895 0.0 0.0 0.0 0.0 1.0 20 11201921 0.0 0.40795 0.18905 0.0 0.0 0.0 0.0 1.0 21 11201922 0.0 0.42785 0.16915 0.0 0.0 0.0 0.0 1.0 22 11201923 0.0 0.44775 0.14925 0.0 0.0 0.0 0.0 1.0 23 11201924 0.0 0.46765 0.12935 0.0 0.0 0.0 0.0 1.0 24 11201925 0.0 0.48755 0.10945 0.0 0.0 0.0 0.0 1.0 25 11201926 0.0 0.50745 0.08955 0.0 0.0 0.0 0.0 1.0 26 11201927 0.0 0.52735 0.06965 0.0 0.0 0.0 0.0 1.0 27 11201928 0.0 0.54725 0.04975 0.0 0.0 0.0 0.0 1.0 28 11201929 0.0 0.56715 0.02985 0.0 0.0 0.0 0.0 1.0 29 11201930 0.0 0.58705 0.00995 0.0 0.0 0.0 0.0 1.0 30

$======================================================================$

$ ht str no. 130-1 hot fuel plate $

  • htstr ht strs m pts geom init l.coord refl b.vol axl. incr 11301000 30 11 1 0 0.0
  • htstr mesh locn mesh fmt 11301100 0 1
  • htstr intervals rt. coord 11301101 2 3.810e-4 11301102 8 6.350e-4
  • htstr compxn no. interval 11301201 -2 2 11301202 1 10
  • htstr source interval 11301301 0.0 2 11301302 1.0 10
  • htstr temp mesh pt.

11301401 318.13 11

  • Max. setpoint for RI
  • htstr left vol incr b.cond sa code area/factor ht str no.

11301501 130010000 10000 102 0 2.662e-3 30

  • htstr right vol incr b.cond sa code area/factor ht str no.

11301601 0 0 0 0 2.662e-3 30

  • htstr s. type s. mult left heat right heat ht str no.

11301701 1000 1.02548e-04 0.0 0.0 1 11301702 1000 8.71042e-05 0.0 0.0 2 11301703 1000 9.37872e-05 0.0 0.0 3 11301704 1000 1.03334e-04 0.0 0.0 4 11301705 1000 1.14623e-04 0.0 0.0 5 11301706 1000 1.27146e-04 0.0 0.0 6 11301707 1000 1.39838e-04 0.0 0.0 7 11301708 1000 1.49947e-04 0.0 0.0 8 11301709 1000 1.60000e-04 0.0 0.0 9 11301710 1000 1.71793e-04 0.0 0.0 10 11301711 1000 1.83475e-04 0.0 0.0 11 11301712 1000 1.94819e-04 0.0 0.0 12 11301713 1000 2.05826e-04 0.0 0.0 13 11301714 1000 2.16216e-04 0.0 0.0 14 11301715 1000 2.25763e-04 0.0 0.0 15 11301716 1000 2.34243e-04 0.0 0.0 16 11301717 1000 2.41151e-04 0.0 0.0 17 11301718 1000 2.46767e-04 0.0 0.0 18 11301719 1000 2.49519e-04 0.0 0.0 19 11301720 1000 2.50923e-04 0.0 0.0 20 11301721 1000 2.48171e-04 0.0 0.0 21 11301722 1000 2.44352e-04 0.0 0.0 22 11301723 1000 2.39298e-04 0.0 0.0 23 11301724 1000 2.33569e-04 0.0 0.0 24 11301725 1000 2.20372e-04 0.0 0.0 25

11301726 1000 2.06837e-04 0.0 0.0 26 11301727 1000 1.91730e-04 0.0 0.0 27 11301728 1000 1.80442e-04 0.0 0.0 28 11301729 1000 1.77634e-04 0.0 0.0 29 11301730 1000 1.74770e-04 0.0 0.0 30

  • htstr heat diam h len-f h len-r glf glr k-f k-r f ht str no.

11301801 4.47e-3 0.00995 0.58705 0.0 0.0 0.0 0.0 1.0 1 11301802 4.47e-3 0.02985 0.56715 0.0 0.0 0.0 0.0 1.0 2 11301803 4.47e-3 0.04975 0.54725 0.0 0.0 0.0 0.0 1.0 3 11301804 4.47e-3 0.06965 0.52735 0.0 0.0 0.0 0.0 1.0 4 11301805 4.47e-3 0.08955 0.50745 0.0 0.0 0.0 0.0 1.0 5 11301806 4.47e-3 0.10945 0.48755 0.0 0.0 0.0 0.0 1.0 6 11301807 4.47e-3 0.12935 0.46765 0.0 0.0 0.0 0.0 1.0 7 11301808 4.47e-3 0.14925 0.44775 0.0 0.0 0.0 0.0 1.0 8 11301809 4.47e-3 0.16915 0.42785 0.0 0.0 0.0 0.0 1.0 9 11301810 4.47e-3 0.18905 0.40795 0.0 0.0 0.0 0.0 1.0 10 11301811 4.47e-3 0.20895 0.38805 0.0 0.0 0.0 0.0 1.0 11 11301812 4.47e-3 0.22885 0.36815 0.0 0.0 0.0 0.0 1.0 12 11301813 4.47e-3 0.24875 0.34825 0.0 0.0 0.0 0.0 1.0 13 11301814 4.47e-3 0.26865 0.32835 0.0 0.0 0.0 0.0 1.0 14 11301815 4.47e-3 0.28855 0.30845 0.0 0.0 0.0 0.0 1.0 15 11301816 4.47e-3 0.30845 0.28855 0.0 0.0 0.0 0.0 1.0 16 11301817 4.47e-3 0.32835 0.26865 0.0 0.0 0.0 0.0 1.0 17 11301818 4.47e-3 0.34825 0.24875 0.0 0.0 0.0 0.0 1.0 18 11301819 4.47e-3 0.36815 0.22885 0.0 0.0 0.0 0.0 1.0 19 11301820 4.47e-3 0.38805 0.20895 0.0 0.0 0.0 0.0 1.0 20 11301821 4.47e-3 0.40795 0.18905 0.0 0.0 0.0 0.0 1.0 21 11301822 4.47e-3 0.42785 0.16915 0.0 0.0 0.0 0.0 1.0 22 11301823 4.47e-3 0.44775 0.14925 0.0 0.0 0.0 0.0 1.0 23 11301824 4.47e-3 0.46765 0.12935 0.0 0.0 0.0 0.0 1.0 24 11301825 4.47e-3 0.48755 0.10945 0.0 0.0 0.0 0.0 1.0 25 11301826 4.47e-3 0.50745 0.08955 0.0 0.0 0.0 0.0 1.0 26 11301827 4.47e-3 0.52735 0.06965 0.0 0.0 0.0 0.0 1.0 27 11301828 4.47e-3 0.54725 0.04975 0.0 0.0 0.0 0.0 1.0 28 11301829 4.47e-3 0.56715 0.02985 0.0 0.0 0.0 0.0 1.0 29 11301830 4.47e-3 0.58705 0.00995 0.0 0.0 0.0 0.0 1.0 30

  • htstr heat diam h len-f h len-r glf glr k-f k-r f ht str no.

11301901 0.0 0.00995 0.58705 0.0 0.0 0.0 0.0 1.0 1 11301902 0.0 0.02985 0.56715 0.0 0.0 0.0 0.0 1.0 2 11301903 0.0 0.04975 0.54725 0.0 0.0 0.0 0.0 1.0 3 11301904 0.0 0.06965 0.52735 0.0 0.0 0.0 0.0 1.0 4 11301905 0.0 0.08955 0.50745 0.0 0.0 0.0 0.0 1.0 5 11301906 0.0 0.10945 0.48755 0.0 0.0 0.0 0.0 1.0 6 11301907 0.0 0.12935 0.46765 0.0 0.0 0.0 0.0 1.0 7 11301908 0.0 0.14925 0.44775 0.0 0.0 0.0 0.0 1.0 8 11301909 0.0 0.16915 0.42785 0.0 0.0 0.0 0.0 1.0 9 11301910 0.0 0.18905 0.40795 0.0 0.0 0.0 0.0 1.0 10 11301911 0.0 0.20895 0.38805 0.0 0.0 0.0 0.0 1.0 11 11301912 0.0 0.22885 0.36815 0.0 0.0 0.0 0.0 1.0 12 11301913 0.0 0.24875 0.34825 0.0 0.0 0.0 0.0 1.0 13 11301914 0.0 0.26865 0.32835 0.0 0.0 0.0 0.0 1.0 14 11301915 0.0 0.28855 0.30845 0.0 0.0 0.0 0.0 1.0 15 11301916 0.0 0.30845 0.28855 0.0 0.0 0.0 0.0 1.0 16 11301917 0.0 0.32835 0.26865 0.0 0.0 0.0 0.0 1.0 17 11301918 0.0 0.34825 0.24875 0.0 0.0 0.0 0.0 1.0 18

11301919 0.0 0.36815 0.22885 0.0 0.0 0.0 0.0 1.0 19 11301920 0.0 0.38805 0.20895 0.0 0.0 0.0 0.0 1.0 20 11301921 0.0 0.40795 0.18905 0.0 0.0 0.0 0.0 1.0 21 11301922 0.0 0.42785 0.16915 0.0 0.0 0.0 0.0 1.0 22 11301923 0.0 0.44775 0.14925 0.0 0.0 0.0 0.0 1.0 23 11301924 0.0 0.46765 0.12935 0.0 0.0 0.0 0.0 1.0 24 11301925 0.0 0.48755 0.10945 0.0 0.0 0.0 0.0 1.0 25 11301926 0.0 0.50745 0.08955 0.0 0.0 0.0 0.0 1.0 26 11301927 0.0 0.52735 0.06965 0.0 0.0 0.0 0.0 1.0 27 11301928 0.0 0.54725 0.04975 0.0 0.0 0.0 0.0 1.0 28 11301929 0.0 0.56715 0.02985 0.0 0.0 0.0 0.0 1.0 29 11301930 0.0 0.58705 0.00995 0.0 0.0 0.0 0.0 1.0 30

$======================================================================$

  • hs 205-1 heat exchanger

$======================================================================$

  • htstr ht strs m pts geom init l.coord refl b.vol axl. incr 12051000 20 11 1 0 0.0
  • htstr mesh locn mesh fmt 12051100 0 1
  • htstr intervals rt. coord 12051101 2.01 12051102 8.1
  • htstr compxn no. interval 12051201 3 2 12051202 3 10
  • htstr source interval 12051301 0.0 2 12051302 1.0 10
  • htstr temp mesh pt.

12051401 318.13 11

  • htstr left vol incr b.cond sa code area/factor ht str no.

12051501 205010000 10000 100 0 100. 20

  • htstr right vol incr b.cond sa code area/factor ht str no.

12051601 0 0 0 0 100. 20

  • htstr s. type s. mult left heat right heat ht str no.

12051701 0 3.85097e-3 0.0 0.0 20

  • htstr heat diam h len-f h len-r glf glr k-f k-r f ht str no.

12051801 0. 0.00995 0.58705 0.0 0.0 0.0 0.0 1.0 20

  • htstr heat diam h len-f h len-r glf glr k-f k-r f ht str no.

12051901 0.0 0.00995 0.58705 0.0 0.0 0.0 0.0 1.0 20

$======================================================================$

  • hs 211-1 outlet duct walls

$======================================================================$

  • htstr ht strs m pts geom init l.coord refl b.vol axl. incr 12111000 20 11 1 0 0.0
  • htstr mesh locn mesh fmt 12111100 0 1
  • htstr intervals rt. coord 12111101 10.009525
  • htstr compxn no. interval 12111201 4 10
  • htstr source interval 12111301 0.0 10
  • htstr temp mesh pt.

12111401 318.13 11

  • htstr left vol incr b.cond sa code area/factor ht str no.

12111501 211010000 10000 100 0.321 20

  • htstr right vol incr b.cond sa code area/factor ht str no.

12111601 401010000 10000 100 0.321 20

  • htstr s. type s. mult left heat right heat ht str no.

12111701 0 3.85097e-3 0.0 0.0 20

  • htstr heat diam h len-f h len-r glf glr k-f k-r f ht str no.

12111801.253 0.00995 0.58705 0.0 0.0 0.0 0.0 1.0 20

  • htstr heat diam h len-f h len-r glf glr k-f k-r f ht str no.

12111901 0.0 0.00995 0.58705 0.0 0.0 0.0 0.0 1.0 20

$======================================================================$

$ thermal properties of composition 1 - U-Al-Si fuel meat $

  • compxn composition th.con flg ht.cap flg material 20100100 tbl/fctn 1 1 *U-Si3-Al
  • compxn temperature th. cond.

20100101 273.0 59.6 20100102 300.0 59.65 20100103 350.0 59.79 20100104 400.0 59.79 20100105 500.0 59.65 20100106 600.0 59.42 20100107 700.0 59.128 20100108 800.0 58.82 20100109 900.0 58.45 20100110 933.0 58.34 20100111 1000.0 46.49 20100112 1100.0 47.1 20100113 1200.0 47.6

  • compxn temperature vol. ht. cap.

20100151 273.0 2.57e+06 20100152 300.0 2.64e+06

20100153 400.0 2.76e+06 20100154 500.0 2.91e+06 20100155 600.0 3.04e+06 20100156 700.0 3.17e+06 20100157 800.0 3.30e+06 20100158 900.0 3.43e+06 20100159 933.0 3.47e+06 20100160 1000.0 3.47e+06 20100161 1100.0 3.52e+06 20100162 1200.0 3.56e+06

$======================================================================$

$ thermal properties of composition 2 - Al $

  • compxn composition th.con flg ht.cap flg material 20100200 tbl/fctn 1 1 *Al
  • compxn temperature th. cond.

20100201 273.0 236.0 20100202 300.0 237.0 20100203 350.0 240.0 20100204 400.0 240.0 20100205 500.0 237.0 20100206 600.0 232.0 20100207 700.0 226.0 20100208 800.0 220.0 20100209 900.0 213.0 20100210 933.0 211.0 20100211 1000.0 93.0 20100212 1100.0 96.4 20100213 1200.0 99.4

  • compxn temperature vol. ht. cap.

20100251 273.0 2.38e+06 20100252 300.0 2.45e+06 20100253 400.0 2.57e+06 20100254 500.0 2.69e+06 20100255 600.0 2.82e+06 20100256 700.0 2.94e+06 20100257 800.0 3.06e+06 20100258 900.0 3.19e+06 20100259 933.0 3.22e+06 20100260 1000.0 3.18e+06 20100261 1100.0 3.18e+06 20100262 1200.0 3.18e+06

$======================================================================$

$ thermal properties of composition 3 - heat sink $

  • compxn composition th.con flg ht.cap flg material 20100300 tbl/fctn 1 1
  • heat sink
  • compxn temperature th. cond.

20100301 273.0 400.0 20100302 10000. 400.0

  • compxn temperature vol. ht. cap.

20100351 273.0 5.00e+12

20100352 10000. 5.00e+12

$======================================================================$

$ thermal properties of composition 4 - stainless steel $

  • compxn composition th.con flg ht.cap flg material 20100400 tbl/fctn 1 1
  • stainless steel
  • compxn temperature th. cond.

20100401 290. 14.83

  • Type 304 stainless steel 20100402 573. 19.37
  • Type 304 staniless steel 20100403 873. 23.62
  • Type 304 staniless steel 20100404 1144. 27.20
  • Type 304 staniless steel 20100405 10000. 27.20
  • Type 304 staniless steel
  • compxn temperature vol. ht. cap.

20100451 290. 3.810e6* Type 304 stainless steel 20100452 573. 4.343e6* Type 304 stainless steel 20100453 873. 4.600e6* Type 304 stainless steel 20100454 1144. 4.792e6* Type 304 stainless steel 20100455 10000. 4.792e6* Type 304 stainless steel

$======================================================================$

  • reactor point kinetics input
  • For the steady-state or transient calculation, the initial power
  • level is for a cold clean core just at the point of criticality.
  • This is ~0.1% of rated steady-state power:
  • 0.1%
  • 2 MW = 2 kW = 2.0e3 W

$======================================================================$

30000000 point separabl

  • power initial react bol decay 30000001 gamma 2.3e6 0.0 108.8 1.0
  • 30000001 gamma 1.0 0.0 111.86 1.0
  • mev/fis pf-235 pf-u238 pf-pu239 groups 30000002 ans79-1 200.0 1.0 0.0 0.0 6 0 0
  • fraction decay constant 30000101 0.035189 0.013337 30000102 0.181465 0.032712 30000103 0.174594 0.12075 30000104 0.383727 0.30279 30000105 0.158734 0.84966 30000106 0.066292 2.8538
  • power time 30000401 2.3e6 3120.0 wk
  • 30000402 2.4e6 40. hr
  • 30000401 1.0 10000.0 wk
  • 30000402 1.0 40. hr

$======================================================================$

$======================================================================$

30000011 1

$======================================================================$

$ table no. 1 - control rods

  • table table type trip no. factor 1 factor 2 20200100 reac-t 1
  • table time (sec) reactivity ($)
  • 20200101 -1.0 0.0
  • 20200102 10000. 0.0 20200102 0.0 0.0 20200103 40. 0.10495 20200104 500.1 0.10495
  • 20200105 501.0 -1.309
  • 20200106 10000. -1.309 20200105 501.0 -1.22005 20200106 10000. -1.22005

$======================================================================$

  • feedback tables

$======================================================================$

  • Density Feedback for single and two-phase liquid
  • density (kg/m^3) reactivity ($)

30000501 10. -27.72 30000502 945.68 -2.7895 30000503 960.50 -2.1062 30000504 967.33 -1.7600 30000505 973.33 -1.4107 30000506 979.49 -1.0966 30000507 984.73 -.7970 30000508 989.40 -.5132 30000509 993.36 -.2463 30000510 996.54 0.

  • Doppler Feedback (LEU Fuel)
  • temperature (K) reactivity ($)

30000601 300. 0.0 30000602 350. -.1124 30000603 400. -.2445 30000604 500. -.4864 30000605 600. -.7045 30000606 800. -1.0898

  • volume increment weighting factor coefficient 30000701 120010000 0 3.67116e-4 0.

30000702 120020000 0 2.04057e-3 0.

30000703 120030000 0 5.00653e-3 0.

30000704 120040000 0 9.14555e-3 0.

30000705 120050000 0 1.42867e-2 0.

30000706 120060000 0 2.02147e-2 0.

30000707 120070000 0 2.66796e-2 0.

30000708 120080000 0 3.34073e-2 0.

30000709 120090000 0 4.01114e-2 0.

30000710 120100000 0 4.65061e-2 0.

30000711 120110000 0 5.23178e-2 0.

30000712 120120000 0 5.72979e-2 0.

30000713 120130000 0 6.12328e-2 0.

30000714 120140000 0 6.39540e-2 0.

30000715 120150000 0 6.53446e-2 0.

30000716 120160000 0 6.53449e-2 0.

30000717 120170000 0 6.39549e-2 0.

30000718 120180000 0 6.12343e-2 0.

30000719 120190000 0 5.72998e-2 0.

30000720 120200000 0 5.25380e-2 0.

30000721 120210000 0 4.67024e-2 0.

30000722 120220000 0 4.02813e-2 0.

30000723 120230000 0 3.35493e-2 0.

30000724 120240000 0 2.67936e-2 0.

30000725 120250000 0 2.03016e-2 0.

30000726 120260000 0 1.43486e-2 0.

30000727 120270000 0 9.18568e-3 0.

30000728 120280000 0 5.02894e-3 0.

30000729 120290000 0 2.05009e-3 0.

30000730 120300000 0 3.69085e-4 0.

30000731 130010000 0 1.52832e-6 0.

30000732 130020000 0 8.49498e-6 0.

30000733 130030000 0 2.08424e-5 0.

30000734 130040000 0 3.80733e-5 0.

30000735 130050000 0 5.94759e-5 0.

30000736 130060000 0 8.41546e-5 0.

30000737 130070000 0 1.11068e-4 0.

30000738 130080000 0 1.39076e-4 0.

30000739 130090000 0 1.66986e-4 0.

30000740 130100000 0 1.93607e-4 0.

30000741 130110000 0 2.17801e-4 0.

30000742 130120000 0 2.38533e-4 0.

30000743 130130000 0 2.54915e-4 0.

30000744 130140000 0 2.66243e-4 0.

30000745 130150000 0 2.72032e-4 0.

30000746 130160000 0 2.72033e-4 0.

30000747 130170000 0 2.66247e-4 0.

30000748 130180000 0 2.54921e-4 0.

30000749 130190000 0 2.38541e-4 0.

30000750 130200000 0 2.17811e-4 0.

30000751 130210000 0 1.93618e-4 0.

30000752 130220000 0 1.66998e-4 0.

30000753 130230000 0 1.39088e-4 0.

30000754 130240000 0 1.11080e-4 0.

30000755 130250000 0 8.41660e-5 0.

30000756 130260000 0 5.94861e-5 0.

30000757 130270000 0 3.80818e-5 0.

30000758 130280000 0 2.08489e-5 0.

30000759 130290000 0 8.49923e-6 0.

30000760 130300000 0 1.53014e-6 0.

  • ht str increment weighting factor coefficient 30000801 1201001 0 3.67116e-4 0.

30000802 1201002 0 2.04057e-3 0.

30000803 1201003 0 5.00653e-3 0.

30000804 1201004 0 9.14555e-3 0.

30000805 1201005 0 1.42867e-2 0.

30000806 1201006 0 2.02147e-2 0.

30000807 1201007 0 2.66796e-2 0.

30000808 1201008 0 3.34073e-2 0.

30000809 1201009 0 4.01114e-2 0.

30000810 1201010 0 4.65061e-2 0.

30000811 1201011 0 5.23178e-2 0.

30000812 1201012 0 5.72979e-2 0.

30000813 1201013 0 6.12328e-2 0.

30000814 1201014 0 6.39540e-2 0.

30000815 1201015 0 6.53446e-2 0.

30000816 1201016 0 6.53449e-2 0.

30000817 1201017 0 6.39549e-2 0.

30000818 1201018 0 6.12343e-2 0.

30000819 1201019 0 5.72998e-2 0.

30000820 1201020 0 5.25380e-2 0.

30000821 1201021 0 4.67024e-2 0.

30000822 1201022 0 4.02813e-2 0.

30000823 1201023 0 3.35493e-2 0.

30000824 1201024 0 2.67936e-2 0.

30000825 1201025 0 2.03016e-2 0.

30000826 1201026 0 1.43486e-2 0.

30000827 1201027 0 9.18568e-3 0.

30000828 1201028 0 5.02894e-3 0.

30000829 1201029 0 2.05009e-3 0.

30000830 1201030 0 3.69085e-4 0.

30000831 1301001 0 1.52832e-6 0.

30000832 1301002 0 8.49498e-6 0.

30000833 1301003 0 2.08424e-5 0.

30000834 1301004 0 3.80733e-5 0.

30000835 1301005 0 5.94759e-5 0.

30000836 1301006 0 8.41546e-5 0.

30000837 1301007 0 1.11068e-4 0.

30000838 1301008 0 1.39076e-4 0.

30000839 1301009 0 1.66986e-4 0.

30000840 1301010 0 1.93607e-4 0.

30000841 1301011 0 2.17801e-4 0.

30000842 1301012 0 2.38533e-4 0.

30000843 1301013 0 2.54915e-4 0.

30000844 1301014 0 2.66243e-4 0.

30000845 1301015 0 2.72032e-4 0.

30000846 1301016 0 2.72033e-4 0.

30000847 1301017 0 2.66247e-4 0.

30000848 1301018 0 2.54921e-4 0.

30000849 1301019 0 2.38541e-4 0.

30000850 1301020 0 2.17811e-4 0.

30000851 1301021 0 1.93618e-4 0.

30000852 1301022 0 1.66998e-4 0.

30000853 1301023 0 1.39088e-4 0.

30000854 1301024 0 1.11080e-4 0.

30000855 1301025 0 8.41660e-5 0.

30000856 1301026 0 5.94861e-5 0.

30000857 1301027 0 3.80818e-5 0.

30000858 1301028 0 2.08489e-5 0.

30000859 1301029 0 8.49923e-6 0.

30000860 1301030 0 1.53014e-6 0.

$======================================================================$

  • control variables

$======================================================================$

  • ctlvar cntrlvar type card 20500000 999

$======================================================================$

  • ctlvar name type factor init f c min max 20500100 "Tin F" sum 1.0 86. 1 0
  • ctlvar a0 coeff variable name parameter no.

20500101 -459.67 1.8 tempf 110010000

$======================================================================$

  • ctlvar name type factor init f c min max 20500200 "Tout F" sum 1.0 86.0138 1 0
  • ctlvar a0 coeff variable name parameter no.

20500201 -459.67 1.8 tempf 180010000

$======================================================================$

  • ctlvar name type factor init f c min max 20500300 "Pin psia" mult 1.45038e-4 23.24426 1 0
  • ctlvar variable name parameter no. variable name parameter no.

20500301 p 110010000

$======================================================================$

  • ctlvar name type factor init f c min max 20500400 "core dp" sum 1.45038e-4 -.733262 1 0
  • ctlvar a0 coeff variable name parameter no.

20500401 0.0 1.0 p 110010000 20500402 -1.0 p 180010000

$======================================================================$

  • ctlvar name type factor init f c min max 20500500 "Qtot gpm" mult 6325.62 1730. 1 1 1.e-6
  • ctlvar variable name parameter no. variable name parameter no.

20500501 voidfj 211010000 velfj 211010000

$======================================================================$

  • ctlvar name type factor init f c min max 20500600 "Qavg gpm" mult 788.998 671.656 1 0
  • ctlvar variable name parameter no. variable name parameter no.

20500601 voidfj 170010000 velfj 170010000

$======================================================================$

  • ctlvar name type factor init f c min max 20500700 "Qavg/ass" mult 0.0041841 2.810276 1 0
  • ctlvar variable name parameter no. variable name parameter no.

20500701 cntrlvar 6

$======================================================================$

  • ctlvar name type factor init f c min max 20500800 "Qhot gpm" mult 3.3015 2.810535 1 0
  • ctlvar variable name parameter no. variable name parameter no.

20500801 voidfj 170020000 velfj 170020000

$======================================================================$

  • ctlvar name type factor init f c min max 20500900 "Qref gpm" mult 114.751 87.3464 1 0
  • ctlvar variable name parameter no. variable name parameter no.

20500901 voidfj 180020000 velfj 180020000

$======================================================================$

  • ctlvar name type factor init f c min max 20501000 "Qbld gpm" mult 269.445 239.555 1 0
  • ctlvar variable name parameter no. variable name parameter no.

20501001 voidfj 180030000 velfj 180030000

$======================================================================$

  • ctlvar name type factor init f c min max 20501200 "qbyp gpm" sum 1.0 380.646 1 0
  • ctlvar a0 coeff variable name parameter no.

20501201 0.0 1.0 cntrlvar 9 20501202 1.0 cntrlvar 10

$======================================================================$

  • ctlvar name type factor init f c min max 20501300 "byp frac" div 1.0.360763 1
  • ctlvar variable name parameter no. variable name parameter no.

20501301 cntrlvar 5 cntrlvar 12

$======================================================================$

  • ctlvar name type factor init f c min max 20501400 "g avg " mult 1.0 847.683 1 0
  • ctlvar variable name parameter no. variable name parameter no.

20501401 rhofj 115010000 velfj 115010000

$======================================================================$

  • ctlvar name type factor init f c min max 20501500 "ref avg " div 5.924e-3 6298.9 1
  • ctlvar variable name parameter no. variable name parameter no.

20501501 viscf 115010000 cntrlvar 14

$======================================================================$

  • ctlvar name type factor init f c min max 20501600 "g ref " mult 1.0 757.971 1 0
  • ctlvar variable name parameter no. variable name parameter no.

20501601 rhofj 110020000 velfj 110020000

$======================================================================$

  • ctlvar name type factor init f c min max 20501700 "ref flow" div 9.40e-3 8937.11 1
  • ctlvar variable name parameter no. variable name parameter no.

20501701 viscf 115010000 cntrlvar 16

$======================================================================$

$ ******************* DISCLAIMER ******************* $

$ This deck has NOT received final checkout. Neither LITCO nor NRC $

$ assumes any responsibility for errors in either the calcu- $

$ lated results or judgments based on those results. $

$ ******************* DISCLAIMER ******************* $

$======================================================================$

. end of deck