Text
- RINSC leu fuel cell 7/98 CELL 6 NPLATE 1 SEQUENCE 2 NGROUP 34 7 7 NMESH 8 8 NREGION 4 0 4 NMATERIAL 4 1 PREOUT LAST PRELUDE CARD INITITIATE 1st MAIN DATA CARD SLAB 1 0.02540 1 MEAT SLAB 2 0.06350 2 CLAD SLAB 3 0.17530 3 D2O SLAB 4 0.17751 4 Xtra region sideplate & water gap MESH 2 2 2 2 MATERIAL 1 -1 300.0 1 27 3.88984E-02 29 5.94365E-03 $
Meat 235.1 1.75523E-03 238.1 7.04193E-03 149 1.00E-20 $
135 1.000E-20 3239.1 1.000E-20 $
240.1 1.000E-20 241.1 1.000E-20 242.1 1.000E-20 $
1241.1 1.000E-20 1149 1.000E-20 2135 1.000E-20 $
236.1 1.00E-20 1238.1 1.000E-20 237.1 1.00E-20 MATERIAL 2 -1 300.0 2 27 6.02669E-02 10 2.98636E-07 $
Al clad 11 1.21115E-06 MATERIAL 3 -1 300.0 3 2001 6.68610E-02 16 3.34305E-02 H2O MATERIAL 4 -1 300.0 4 27 4.2673E-02 2001 1.9519E-02 $
Xtra region 16 9.7597E-03 FEWGROUPS 3 5 6 8 10 13 15 16 18 20 22 24 26 27 29 32 34 37 $
38 40 42 44 45 47 50 52 54 56 59 60 61 64 66 69 POWERC 1 519 0.0 1 BEGINC end of DATA OPTION 3 full edit BUCKLING 2.77E-03 2.33E-03 B-sq no eff on xs LEAKAGE 5 1 BEEONE 0 7 PARTITION 5 15 27 45 52 59 69 RR EDIT THERMAL 10 REGION 1 3 1 4 ISOXS 0 1 0 0 0 1 1 0 0 HUSE RINSC isotxs
HSETID RINSC LEU Fuel region ISOTOPES 2001 16 27 10 11 29 ISONAMES HF4 OF4 ALF4 B10F4 B11F4 SIF4 EDITCELLS 1 1 1 0 VECTOR 2 7 14 23 26 29 34 relate FEWGROUPS BEGINC