ML13128A407

From kanterella
Jump to navigation Jump to search
Response to RAI 4.11 DIF3D Doppler T450 Noxe Noi
ML13128A407
Person / Time
Site: Rhode Island Atomic Energy Commission
Issue date: 03/15/2013
From: Marlone Davis
State of RI, Atomic Energy Comm
To: William Kennedy
Division of Policy and Rulemaking
References
Download: ML13128A407 (15)


Text

BLOCK=OLD DATASET=ISOTXS BLOCK=STP027,3 DATASET=A.STP027 01 0 0 0 1 0 0 0 0 0 0 1 02 0 1 0 2 0 0 0 0 0 0 03 1 0 1 0 0 1 0 0000000010000 DATASET=A.DIF3D 01 RINSC LEU 9/30/98 02 20000900000 0 03 0 0 0 0 150 0 0 8 0 0 50 04 0 0 0 01 000 10 000 0 0 0000 0 05 1.0E-7 5.0E-5 5.0E-5 06 1.00000E-0 0.001 0.004 2.000-6 1.0000 DATASET=A.HMG4C 01 RINSC LEU Eq. Core at step 9c, rearrange 4 innermost FAs ALL RODS 100% OUT 2-2010 02 500000 1 0 0 0 0 0 0 DATASET=A.NIP3 01 RINSC LEU STARTUP CORE 01 ALL CONTROL BLADES FULL OUT 01 REG ROD FULL OUT 02 1 25000 1 03 44 04 2 2 2 2 2 2 06 H2ORFO 0.0 113.03 0 37 0.0 160.0 06 TCB1 0.0 113.03 0 37 0.0 29.527 06 TCB2 11.43 101.60 5 33 0.0 52.387 06 TC1 0.0 113.03 0 37 0.0 26.987 06 TC2 13.97 99.06 6 32 26.987 49.847 06 GSBOX 26.352 86.678 5 28 52.387 63.187 06 SHIELD 27.940 85.090 8 27 53.977 61.597 06 GRID 26.085 86.945 2 4 63.822 135.146 06 GBOX 26.085 86.945 4 31 63.822 135.146 06 H2ORFI 26.720 86.310 4 31 64.457 134.511 06 AXREFT 26.773 86.257 26 31 64.51 134.458 06 AXREFB 26.773 86.257 4 9 64.51 134.458 06 POST1 26.085 34.545 4 31 63.822 72.282 06 POST2 26.085 34.545 4 31 126.686 135.146 06 POST3 78.485 86.945 4 31 63.822 72.282 06 POST4 78.485 86.945 4 31 126.686 135.146 06 GRAF1 44.857 68.173 7 29 64.51 72.282 01 moved 5 Be to core boundary E8 D8 C8 E2 C2 11/98 06 BEEC8 44.857 68.173 7 29 118.914 126.686 06 BE-E2 44.857 52.629 7 29 72.282 80.054 06 BE-C2 60.401 68.173 7 29 72.282 80.054 06 GRAF5 34.545 42.317 7 29 64.51 126.686 06 BEF5A 34.545 42.317 9 26 80.054 118.914 Be 06 GRAF6 70.713 78.485 7 29 64.51 126.686 06 BEF6A 70.713 78.485 9 26 80.054 118.914 Be 01 move 2 BE away BE1 26.773 34.545 9 26 72.282 126.686 06 GRAG1 26.773 34.545 9 26 72.282 126.686 G 01 move 2 Be away BE2 78.485 86.257 9 26 72.282 126.686 06 GRAG2 78.485 86.257 9 26 72.282 126.686 G 06 FC 78.485 86.257 35 37 126.686 134.458 06 CIC 26.773 34.545 35 37 126.686 134.458 01 RBBL1S to BE-F9 11/98 06 BE-F9 34.545 42.317 9 26 126.686 134.458 01 RBBL2S to BE-E9 updated from rinsc info 8/98 01 removed RB box 11/98 06 RBBL2E 45.351 52.135 9 26 126.686 134.458 01 removed 06 RB2 45.351 52.135 9 26 127.0417 134.1023 06 G-E9 44.857 52.629 9 26 126.686 134.458 06 RBBL3S 52.629 60.401 9 26 126.686 134.458 06 RBBL3E 53.123 59.907 9 26 126.686 134.458 06 RB3 53.123 59.907 9 26 127.0417 134.1023 06 RBBL4S 60.401 68.173 9 26 126.686 134.458 06 RBBL4E 60.895 67.679 9 26 126.686 134.458 06 RB4 60.895 67.679 9 26 127.0417 134.1023 06 RBBL5S 70.713 78.485 9 26 126.686 134.458 06 RBBL5E 71.207 77.991 9 26 126.686 134.458 06 RB5 71.207 77.991 9 26 127.0417 134.1023 06 E3A 44.857 52.629 9 13 80.054 87.826 06 E4A 44.857 52.629 9 13 87.826 95.598 06 E5A 44.857 52.629 9 13 95.598 103.370 06 E6A 44.857 52.629 9 13 103.370 111.142 06 E7A 44.857 52.629 9 13 111.142 118.914 06 D3A 52.629 60.401 9 13 80.054 87.826 06 D4A 52.629 60.401 9 13 87.826 95.598 06 D6A 52.629 60.401 9 13 103.370 111.142 06 D7A 52.629 60.401 9 13 111.142 118.914 06 C3A 60.401 68.173 9 13 80.054 87.826 06 C4A 60.401 68.173 9 13 87.826 95.598

06 C5A 60.401 68.173 9 13 95.598 103.370 06 C6A 60.401 68.173 9 13 103.370 111.142 06 C7A 60.401 68.173 9 13 111.142 118.914 06 E3B 44.857 52.629 13 17 80.054 87.826 06 E4B 44.857 52.629 13 17 87.826 95.598 06 E5B 44.857 52.629 13 17 95.598 103.370 06 E6B 44.857 52.629 13 17 103.370 111.142 06 E7B 44.857 52.629 13 17 111.142 118.914 06 D3B 52.629 60.401 13 17 80.054 87.826 06 D4B 52.629 60.401 13 17 87.826 95.598 06 D6B 52.629 60.401 13 17 103.370 111.142 06 D7B 52.629 60.401 13 17 111.142 118.914 06 C3B 60.401 68.173 13 17 80.054 87.826 06 C4B 60.401 68.173 13 17 87.826 95.598 06 C5B 60.401 68.173 13 17 95.598 103.370 06 C6B 60.401 68.173 13 17 103.370 111.142 06 C7B 60.401 68.173 13 17 111.142 118.914 06 E3C 44.857 52.629 17 21 80.054 87.826 06 E4C 44.857 52.629 17 21 87.826 95.598 06 E5C 44.857 52.629 17 21 95.598 103.370 06 E6C 44.857 52.629 17 21 103.370 111.142 06 E7C 44.857 52.629 17 21 111.142 118.914 06 D3C 52.629 60.401 17 21 80.054 87.826 06 D4C 52.629 60.401 17 21 87.826 95.598 06 D6C 52.629 60.401 17 21 103.370 111.142 06 D7C 52.629 60.401 17 21 111.142 118.914 06 C3C 60.401 68.173 17 21 80.054 87.826 06 C4C 60.401 68.173 17 21 87.826 95.598 06 C5C 60.401 68.173 17 21 95.598 103.370 06 C6C 60.401 68.173 17 21 103.370 111.142 06 C7C 60.401 68.173 17 21 111.142 118.914 06 E3D 44.857 52.629 21 26 80.054 87.826 06 E4D 44.857 52.629 21 26 87.826 95.598 06 E5D 44.857 52.629 21 26 95.598 103.370 06 E6D 44.857 52.629 21 26 103.370 111.142 06 E7D 44.857 52.629 21 26 111.142 118.914 06 D3D 52.629 60.401 21 26 80.054 87.826 06 D4D 52.629 60.401 21 26 87.826 95.598 06 D6D 52.629 60.401 21 26 103.370 111.142 06 D7D 52.629 60.401 21 26 111.142 118.914 06 C3D 60.401 68.173 21 26 80.054 87.826 06 C4D 60.401 68.173 21 26 87.826 95.598 06 C5D 60.401 68.173 21 26 95.598 103.370 06 C6D 60.401 68.173 21 26 103.370 111.142 06 C7D 60.401 68.173 21 26 111.142 118.914 06 S1 44.857 45.7015 9 26 80.054 118.914 06 S2 51.7845 52.629 9 26 80.054 118.914 06 S3 52.629 53.4735 9 26 80.054 118.914 06 S4 59.5565 60.401 9 26 80.054 118.914 06 S5 60.401 61.2455 9 26 80.054 118.914 06 S6 67.3285 68.173 9 26 80.054 118.914 06 G1 42.317 44.857 9 26 64.51 70.086 06 G2 42.317 44.857 9 26 98.090 100.878 06 G3 42.317 44.857 9 26 128.882 134.458 06 G4 68.173 70.713 9 26 64.51 70.086 06 G5 68.173 70.713 9 26 98.090 100.878 06 G6 68.173 70.713 9 26 128.882 134.458 06 TRAP 52.629 60.401 9 26 95.598 103.370 01 flux trap size different 9/98 **

01 06 HOLE 54.8265 58.2035 9 26 97.7955 101.1725 06 HOLE 54.6861 58.3439 9 26 97.6551 101.3130 01 G1 to G6 CR guide tubes 06 CNTL1O 68.173 70.713 7 30 100.878 128.882 06 CNTL2O 68.173 70.713 7 30 70.086 98.090 06 CNTL3O 42.317 44.857 7 30 70.086 98.090 06 CNTL4O 42.317 44.857 7 30 100.878 128.882 06 CNTL1I 68.173 70.713 30 37 100.878 128.882 06 CNTL2I 68.173 70.713 30 37 70.086 98.090 06 CNTL3I 42.317 44.857 30 37 70.086 98.090 06 CNTL4I 42.317 44.857 30 37 100.878 128.882 06 BLADE1 69.11915 69.76685 30 37 101.507 128.253 06 BLADE2 69.11915 69.76685 30 37 70.715 97.461 06 BLADE3 43.26315 43.91085 30 37 70.715 97.461 06 BLADE4 43.26315 43.91085 30 37 101.507 128.253 06 REGOUT 52.629 60.401 7 37 72.282 80.054 01 make the reg rod fully out 9/98 **

06 REGIN1 52.629 60.401 30 37 72.282 80.054 06 ROD1 53.816 59.214 30 37 73.46925 78.86675 06 REGIN2 54.451 58.579 30 37 74.10425 78.23175 07 E3 E3A E3B E3C E3D 07 E4 E4A E4B E4C E4D

07 E5 E5A E5B E5C E5D 07 E6 E6A E6B E6C E6D 07 E7 E7A E7B E7C E7D 07 D3 D3A D3B D3C D3D 07 D4 D4A D4B D4C D4D 07 D6 D6A D6B D6C D6D 07 D7 D7A D7B D7C D7D 07 C3 C3A C3B C3C C3D 07 C4 C4A C4B C4C C4D 07 C5 C5A C5B C5C C5D 07 C6 C6A C6B C6C C6D 07 C7 C7A C7B C7C C7D 07 FUEL E3A E3B E3C E3D 07 FUEL E4A E4B E4C E4D 07 FUEL E5A E5B E5C E5D 07 FUEL E6A E6B E6C E6D 07 FUEL E7A E7B E7C E7D 07 FUEL D3A D3B D3C D3D 07 FUEL D4A D4B D4C D4D 07 FUEL D6A D6B D6C D6D 07 FUEL D7A D7B D7C D7D 07 FUEL C3A C3B C3C C3D 07 FUEL C4A C4B C4C C4D 07 FUEL C5A C5B C5C C5D 07 FUEL C6A C6B C6C C6D 07 FUEL C7A C7B C7C C7D 09 X 1 11.430000 1 13.970000 1 26.085000 09 X 1 26.352000 1 26.720000 1 26.773000 09 X 1 27.940000 1 34.545000 1 35.039000 09 X 1 41.823000 1 42.317000 1 43.263150 09 X 2 43.910850 1 44.857000 1 45.351000 09 X 1 45.701500 3 51.784500 1 52.135000 09 X 1 52.629000 1 53.123000 1 53.473500 09 X 1 53.816000 2 54.451000 1 54.686100 09 X 2 58.343900 1 58.579000 2 59.214000 09 X 1 59.556500 1 59.907000 1 60.401000 09 X 1 60.895000 1 61.245500 3 67.328500 09 X 1 67.679000 1 68.173000 1 69.119150 09 X 2 69.766850 1 70.713000 1 71.207000 09 X 1 77.991000 1 78.485000 1 85.090000 09 X 1 86.257000 1 86.310000 1 86.678000 09 X 1 86.945000 1 99.060000 1 101.600000 09 X 1 113.030000 09 Y 1 26.987 1 29.527 3 49.847 09 Y 1 52.387 1 53.977 2 61.597 09 Y 1 63.187 1 63.822 1 64.457 09 Y 1 64.51 3 70.086 1 70.715 09 Y 1 72.282 1 73.46925 2 74.10425 09 Y 3 78.23175 2 78.86675 09 Y 2 80.054 2 82.8145 1 85.0655 09 Y 2 87.826 2 90.5865 1 92.8375 09 Y 2 95.598 2 97.461 1 97.6551 09 Y 1 98.090 1 100.878 1 101.3130 09 Y 1 101.507 09 Y 2 103.370 2 106.1305 1 108.3815 09 Y 2 111.142 2 113.9025 1 116.1535 09 Y 2 118.914 09 Y 1 119.2697 3 126.3303 1 126.686 09 Y 1 127.0417 1 128.253 09 Y 1 128.882 1 134.1023 09 Y 1 134.458 1 134.511 1 135.146 09 Y 4 160.0 09 Z 2 13.36 1 26.22 09 Z 1 28.45 1 29.72 09 Z 1 32.26 1 34.16 1 35.75 09 Z 1 37.0175 14 88.690625 2 95.44 09 Z 1 96.0725 09 Z 1 97.35 1 103.38 1 107.503 09 Z 1 110.510 1 116.08 1 117.35 09 Z 1 119.89 2 137.39 2 158.94 13 MEAT U5D3 0 1.75523E-03U8D3 0 7.04193E-03ALF4 0 3.88984E-02 13 MEAT SIF4 0 5.94365E-03 13 MEAT U6D3 0 1.00000E-10P9D3 0 1.00000E-10P0D3 0 1.00000E-10 13 MEAT P1D3 0 1.00000E-10P2D3 0 1.00000E-10FXEB 0 1.00000E-10 13 MEAT FPMB 0 1.00000E-10FSMB 0 1.00000E-10FI5B 0 1.00000E-10 13 MEAT PFP1 0 1.00000E-10ODUM 0 1.00000E-10 13 CLAD ALF4 0 6.02669E-02B10F 0 2.98636E-07B11F 0 1.21115E-06 13 MOD HF4 0 6.68610E-02OF4 0 3.34305E-02 14 NEWF MEAT 0.14380 CLAD 0.21570 MOD 0.64050 14 MNEW NEWF 1.00000 15 MNEW E3A

15 MNEW E3B 15 MNEW E3C 15 MNEW E3D 15 MNEW E7A 15 MNEW E7B 15 MNEW E7C 15 MNEW E7D 15 MNEW C3A 15 MNEW C3B 15 MNEW C3C 15 MNEW C3D 15 MNEW C7A 15 MNEW C7B 15 MNEW C7C 15 MNEW C7D Material composition from EOC at Doppler T450 of rbsc3-step9a run 5-2010 13 MTE3A U5D3 0 1.67636E-03U6D3 0 1.39298E-05U8D3 0 7.03477E-03 $ E3A step9a Doppler T450 13 MTE3A P9D3 0 2.89854E-07P0D3 0 1.10772E-08P1D3 0 2.34409E-06 13 MTE3A P2D3 0 1.07177E-07FXEB 0 1.15167E-18FI5B 0 1.75473E-18 13 MTE3A FPMB 0 2.36321E-08FSMB 0 1.36502E-07PFP1 0 7.14534E-05 13 MTE3A ODUM 0 3.10848E-06 13 MTE3B U5D3 0 1.63950E-03U6D3 0 2.06349E-05U8D3 0 7.03060E-03 $ E3B step9a Doppler T450 13 MTE3B P9D3 0 4.36836E-07P0D3 0 2.46912E-08P1D3 0 3.95250E-06 13 MTE3B P2D3 0 2.72615E-07FXEB 0 1.33512E-18FI5B 0 2.56648E-18 13 MTE3B FPMB 0 3.46085E-08FSMB 0 1.34972E-07PFP1 0 1.05028E-04 13 MTE3B ODUM 0 4.19805E-06 13 MTE3C U5D3 0 1.63887E-03U6D3 0 2.07413E-05U8D3 0 7.03060E-03 $ E3C step9a Doppler T450 13 MTE3C P9D3 0 4.38860E-07P0D3 0 2.49346E-08P1D3 0 3.97900E-06 13 MTE3C P2D3 0 2.75967E-07FXEB 0 1.33720E-18FI5B 0 2.57907E-18 13 MTE3C FPMB 0 3.47796E-08FSMB 0 1.34937E-07PFP1 0 1.05570E-04 13 MTE3C ODUM 0 4.21509E-06 13 MTE3D U5D3 0 1.67462E-03U6D3 0 1.42434E-05U8D3 0 7.03477E-03 $ E3D step9a Doppler T450 13 MTE3D P9D3 0 2.95848E-07P0D3 0 1.15563E-08P1D3 0 2.41739E-06 13 MTE3D P2D3 0 1.13088E-07FXEB 0 1.16259E-18FI5B 0 1.79221E-18 13 MTE3D FPMB 0 2.41391E-08FSMB 0 1.36565E-07PFP1 0 7.30320E-05 13 MTE3D ODUM 0 3.16120E-06 13 MTE4A U5D3 0 1.52406E-03U6D3 0 4.12524E-05U8D3 0 7.01947E-03 $ E4A step9a Doppler T450 13 MTE4A P9D3 0 8.27190E-07P0D3 0 9.25661E-08P1D3 0 6.38866E-06 13 MTE4A P2D3 0 9.33380E-07FXEB 0 1.15786E-18FI5B 0 1.97754E-18 13 MTE4A FPMB 0 2.66961E-08FSMB 0 1.26363E-07PFP1 0 2.09277E-04 13 MTE4A ODUM 0 1.09068E-05 13 MTE4B U5D3 0 1.42170E-03U6D3 0 6.01453E-05U8D3 0 7.00695E-03 $ E4B step9a Doppler T450 13 MTE4B P9D3 0 1.16954E-06P0D3 0 1.91683E-07P1D3 0 9.91168E-06 13 MTE4B P2D3 0 2.25967E-06FXEB 0 1.26718E-18FI5B 0 2.81599E-18 13 MTE4B FPMB 0 3.81168E-08FSMB 0 1.19367E-07PFP1 0 3.02065E-04 13 MTE4B ODUM 0 1.59478E-05 13 MTE4C U5D3 0 1.42010E-03U6D3 0 6.04367E-05U8D3 0 7.00695E-03 $ E4C step9a Doppler T450 13 MTE4C P9D3 0 1.17371E-06P0D3 0 1.93338E-07P1D3 0 9.96384E-06 13 MTE4C P2D3 0 2.28547E-06FXEB 0 1.26794E-18FI5B 0 2.82802E-18 13 MTE4C FPMB 0 3.82816E-08FSMB 0 1.19249E-07PFP1 0 3.03526E-04 13 MTE4C ODUM 0 1.60341E-05 13 MTE4D U5D3 0 1.51940E-03U6D3 0 4.21099E-05U8D3 0 7.01878E-03 $ E4D step9a Doppler T450 13 MTE4D P9D3 0 8.41446E-07P0D3 0 9.60918E-08P1D3 0 6.55424E-06 13 MTE4D P2D3 0 9.80459E-07FXEB 0 1.16460E-18FI5B 0 2.01273E-18 13 MTE4D FPMB 0 2.71752E-08FSMB 0 1.26134E-07PFP1 0 2.13512E-04 13 MTE4D ODUM 0 1.11175E-05 13 MTE5A U5D3 0 1.49534E-03U6D3 0 4.64159E-05U8D3 0 7.01669E-03 $ E5A step9a Doppler T450 13 MTE5A P9D3 0 8.92768E-07P0D3 0 1.14478E-07P1D3 0 7.40960E-06 13 MTE5A P2D3 0 1.23950E-06FXEB 0 1.19388E-18FI5B 0 2.20369E-18 13 MTE5A FPMB 0 2.97663E-08FSMB 0 1.24179E-07PFP1 0 2.35174E-04 13 MTE5A ODUM 0 1.21780E-05 13 MTE5B U5D3 0 1.38324E-03U6D3 0 6.71975E-05U8D3 0 7.00209E-03 $ E5B step9a Doppler T450 13 MTE5B P9D3 0 1.24458E-06P0D3 0 2.31690E-07P1D3 0 1.11307E-05 13 MTE5B P2D3 0 2.91245E-06FXEB 0 1.27809E-18FI5B 0 3.08081E-18 13 MTE5B FPMB 0 4.17371E-08FSMB 0 1.16502E-07PFP1 0 3.36592E-04 13 MTE5B ODUM 0 1.81224E-05 13 MTE5C U5D3 0 1.38150E-03U6D3 0 6.75250E-05U8D3 0 7.00209E-03 $ E5C step9a Doppler T450 13 MTE5C P9D3 0 1.24882E-06P0D3 0 2.33644E-07P1D3 0 1.11864E-05 13 MTE5C P2D3 0 2.94513E-06FXEB 0 1.27858E-18FI5B 0 3.09346E-18 13 MTE5C FPMB 0 4.19117E-08FSMB 0 1.16384E-07PFP1 0 3.38213E-04 13 MTE5C ODUM 0 1.82295E-05 13 MTE5D U5D3 0 1.49013E-03U6D3 0 4.73693E-05U8D3 0 7.01530E-03 $ E5D step9a Doppler T450 13 MTE5D P9D3 0 9.07789E-07P0D3 0 1.18727E-07P1D3 0 7.58901E-06 13 MTE5D P2D3 0 1.30056E-06FXEB 0 1.19910E-18FI5B 0 2.23880E-18 13 MTE5D FPMB 0 3.02462E-08FSMB 0 1.23915E-07PFP1 0 2.39875E-04 13 MTE5D ODUM 0 1.24228E-05 13 MTE6A U5D3 0 1.58373E-03U6D3 0 3.06029E-05U8D3 0 7.02503E-03 $ E6A step9a Doppler T450 13 MTE6A P9D3 0 6.31377E-07P0D3 0 5.19054E-08P1D3 0 5.12163E-06

13 MTE6A P2D3 0 5.36697E-07FXEB 0 1.21467E-18FI5B 0 2.10612E-18 13 MTE6A FPMB 0 2.84145E-08FSMB 0 1.30876E-07PFP1 0 1.55424E-04 13 MTE6A ODUM 0 7.35675E-06 13 MTE6B U5D3 0 1.50633E-03U6D3 0 4.49026E-05U8D3 0 7.01599E-03 $ E6B step9a Doppler T450 13 MTE6B P9D3 0 9.15160E-07P0D3 0 1.10688E-07P1D3 0 8.13143E-06 13 MTE6B P2D3 0 1.31161E-06FXEB 0 1.34791E-18FI5B 0 3.03331E-18 13 MTE6B FPMB 0 4.10139E-08FSMB 0 1.25821E-07PFP1 0 2.25994E-04 13 MTE6B ODUM 0 1.04166E-05 13 MTE6C U5D3 0 1.50501E-03U6D3 0 4.51328E-05U8D3 0 7.01599E-03 $ E6C step9a Doppler T450 13 MTE6C P9D3 0 9.18915E-07P0D3 0 1.11725E-07P1D3 0 8.17942E-06 13 MTE6C P2D3 0 1.32733E-06FXEB 0 1.34910E-18FI5B 0 3.04722E-18 13 MTE6C FPMB 0 4.12051E-08FSMB 0 1.25730E-07PFP1 0 2.27142E-04 13 MTE6C ODUM 0 1.04694E-05 13 MTE6D U5D3 0 1.58004E-03U6D3 0 3.12914E-05U8D3 0 7.02503E-03 $ E6D step9a Doppler T450 13 MTE6D P9D3 0 6.43526E-07P0D3 0 5.40688E-08P1D3 0 5.26878E-06 13 MTE6D P2D3 0 5.65953E-07FXEB 0 1.22281E-18FI5B 0 2.14673E-18 13 MTE6D FPMB 0 2.89659E-08FSMB 0 1.30730E-07PFP1 0 1.58853E-04 13 MTE6D ODUM 0 7.49791E-06 13 MTE7A U5D3 0 1.66912E-03U6D3 0 1.52684E-05U8D3 0 7.03407E-03 $ E7A step9a Doppler T450 13 MTE7A P9D3 0 3.15730E-07P0D3 0 1.32135E-08P1D3 0 2.65278E-06 13 MTE7A P2D3 0 1.33275E-07FXEB 0 1.19624E-18FI5B 0 1.91356E-18 13 MTE7A FPMB 0 2.57789E-08FSMB 0 1.36419E-07PFP1 0 7.80668E-05 13 MTE7A ODUM 0 3.32955E-06 13 MTE7B U5D3 0 1.62921E-03U6D3 0 2.25800E-05U8D3 0 7.02990E-03 $ E7B step9a Doppler T450 13 MTE7B P9D3 0 4.74374E-07P0D3 0 2.93275E-08P1D3 0 4.41217E-06 13 MTE7B P2D3 0 3.34402E-07FXEB 0 1.37281E-18FI5B 0 2.79228E-18 13 MTE7B FPMB 0 3.76683E-08FSMB 0 1.34471E-07PFP1 0 1.14499E-04 13 MTE7B ODUM 0 4.50730E-06 13 MTE7C U5D3 0 1.62851E-03U6D3 0 2.27024E-05U8D3 0 7.02990E-03 $ E7C step9a Doppler T450 13 MTE7C P9D3 0 4.76676E-07P0D3 0 2.96314E-08P1D3 0 4.44263E-06 13 MTE7C P2D3 0 3.38693E-07FXEB 0 1.37490E-18FI5B 0 2.80675E-18 13 MTE7C FPMB 0 3.78644E-08FSMB 0 1.34423E-07PFP1 0 1.15125E-04 13 MTE7C ODUM 0 4.52705E-06 13 MTE7D U5D3 0 1.66704E-03U6D3 0 1.56495E-05U8D3 0 7.03407E-03 $ E7D step9a Doppler T450 13 MTE7D P9D3 0 3.22747E-07P0D3 0 1.38394E-08P1D3 0 2.74332E-06 13 MTE7D P2D3 0 1.41391E-07FXEB 0 1.20807E-18FI5B 0 1.95911E-18 13 MTE7D FPMB 0 2.63950E-08FSMB 0 1.36439E-07PFP1 0 7.99861E-05 13 MTE7D ODUM 0 3.39242E-06 13 MTD3A U5D3 0 1.60362E-03U6D3 0 2.69743E-05U8D3 0 7.02782E-03 $ D3A step9a Doppler T450 13 MTD3A P9D3 0 5.61885E-07P0D3 0 4.06898E-08P1D3 0 4.33630E-06 13 MTD3A P2D3 0 3.98873E-07FXEB 0 1.14645E-18FI5B 0 1.80946E-18 13 MTD3A FPMB 0 2.43971E-08FSMB 0 1.32656E-07PFP1 0 1.37378E-04 13 MTD3A ODUM 0 6.62399E-06 13 MTD3B U5D3 0 1.53470E-03U6D3 0 3.96405E-05U8D3 0 7.01947E-03 $ D3B step9a Doppler T450 13 MTD3B P9D3 0 8.22879E-07P0D3 0 8.76634E-08P1D3 0 7.03547E-06 13 MTD3B P2D3 0 9.90542E-07FXEB 0 1.29771E-18FI5B 0 2.60994E-18 13 MTD3B FPMB 0 3.52587E-08FSMB 0 1.28199E-07PFP1 0 2.00146E-04 13 MTD3B ODUM 0 9.25800E-06 13 MTD3C U5D3 0 1.53352E-03U6D3 0 3.98401E-05U8D3 0 7.01947E-03 $ D3C step9a Doppler T450 13 MTD3C P9D3 0 8.26286E-07P0D3 0 8.84771E-08P1D3 0 7.07858E-06 13 MTD3C P2D3 0 1.00236E-06FXEB 0 1.29923E-18FI5B 0 2.62225E-18 13 MTD3C FPMB 0 3.54263E-08FSMB 0 1.28122E-07PFP1 0 2.01154E-04 13 MTD3C ODUM 0 9.30181E-06 13 MTD3D U5D3 0 1.60042E-03U6D3 0 2.75654E-05U8D3 0 7.02712E-03 $ D3D step9a Doppler T450 13 MTD3D P9D3 0 5.72684E-07P0D3 0 4.23700E-08P1D3 0 4.46252E-06 13 MTD3D P2D3 0 4.20188E-07FXEB 0 1.15577E-18FI5B 0 1.84611E-18 13 MTD3D FPMB 0 2.48936E-08FSMB 0 1.32538E-07PFP1 0 1.40327E-04 13 MTD3D ODUM 0 6.74444E-06 13 MTD4A U5D3 0 1.44611E-03U6D3 0 5.55014E-05U8D3 0 7.01043E-03 $ D4A step9a Doppler T450 13 MTD4A P9D3 0 1.07462E-06P0D3 0 1.61433E-07P1D3 0 8.21905E-06 13 MTD4A P2D3 0 1.68505E-06FXEB 0 1.15348E-18FI5B 0 2.08519E-18 13 MTD4A FPMB 0 2.81857E-08FSMB 0 1.21495E-07PFP1 0 2.79715E-04 13 MTD4A ODUM 0 1.57942E-05 13 MTD4B U5D3 0 1.31530E-03U6D3 0 7.99235E-05U8D3 0 6.99305E-03 $ D4B step9a Doppler T450 13 MTD4B P9D3 0 1.47086E-06P0D3 0 3.17643E-07P1D3 0 1.21085E-05 13 MTD4B P2D3 0 3.93060E-06FXEB 0 1.22031E-18FI5B 0 2.87775E-18 13 MTD4B FPMB 0 3.90264E-08FSMB 0 1.12232E-07PFP1 0 3.97552E-04 13 MTD4B ODUM 0 2.42872E-05 13 MTD4C U5D3 0 1.31321E-03U6D3 0 8.02990E-05U8D3 0 6.99305E-03 $ D4C step9a Doppler T450 13 MTD4C P9D3 0 1.47538E-06P0D3 0 3.20146E-07P1D3 0 1.21634E-05 13 MTD4C P2D3 0 3.97337E-06FXEB 0 1.22045E-18FI5B 0 2.88915E-18 13 MTD4C FPMB 0 3.91836E-08FSMB 0 1.12079E-07PFP1 0 3.99367E-04 13 MTD4C ODUM 0 2.44409E-05 13 MTD4D U5D3 0 1.44033E-03U6D3 0 5.65737E-05U8D3 0 7.00974E-03 $ D4D step9a Doppler T450 13 MTD4D P9D3 0 1.09138E-06P0D3 0 1.66975E-07P1D3 0 8.40195E-06 13 MTD4D P2D3 0 1.76335E-06FXEB 0 1.15779E-18FI5B 0 2.11565E-18 13 MTD4D FPMB 0 2.86022E-08FSMB 0 1.21182E-07PFP1 0 2.84937E-04 13 MTD4D ODUM 0 1.61161E-05

13 MTD6A U5D3 0 1.42865E-03U6D3 0 5.88755E-05U8D3 0 7.00765E-03 $ D6A step9a Doppler T450 13 MTD6A P9D3 0 1.12775E-06P0D3 0 1.79923E-07P1D3 0 8.76704E-06 13 MTD6A P2D3 0 1.93338E-06FXEB 0 1.16280E-18FI5B 0 2.16843E-18 13 MTD6A FPMB 0 2.93227E-08FSMB 0 1.20223E-07PFP1 0 2.95675E-04 13 MTD6A ODUM 0 1.67983E-05 13 MTD6B U5D3 0 1.29228E-03U6D3 0 8.45271E-05U8D3 0 6.98957E-03 $ D6B step9a Doppler T450 13 MTD6B P9D3 0 1.53046E-06P0D3 0 3.49917E-07P1D3 0 1.27058E-05 13 MTD6B P2D3 0 4.44033E-06FXEB 0 1.21885E-18FI5B 0 2.98248E-18 13 MTD6B FPMB 0 4.04701E-08FSMB 0 1.10501E-07PFP1 0 4.18498E-04 13 MTD6B ODUM 0 2.61836E-05 13 MTD6C U5D3 0 1.29013E-03U6D3 0 8.49374E-05U8D3 0 6.98957E-03 $ D6C step9a Doppler T450 13 MTD6C P9D3 0 1.53505E-06P0D3 0 3.52705E-07P1D3 0 1.27629E-05 13 MTD6C P2D3 0 4.48978E-06FXEB 0 1.21892E-18FI5B 0 2.99451E-18 13 MTD6C FPMB 0 4.06363E-08FSMB 0 1.10341E-07PFP1 0 4.20487E-04 13 MTD6C ODUM 0 2.63623E-05 13 MTD6D U5D3 0 1.42211E-03U6D3 0 6.01043E-05U8D3 0 7.00765E-03 $ D6D step9a Doppler T450 13 MTD6D P9D3 0 1.14604E-06P0D3 0 1.86474E-07P1D3 0 8.97288E-06 13 MTD6D P2D3 0 2.03004E-06FXEB 0 1.16690E-18FI5B 0 2.20195E-18 13 MTD6D FPMB 0 2.97809E-08FSMB 0 1.19854E-07PFP1 0 3.01634E-04 13 MTD6D ODUM 0 1.71801E-05 13 MTD7A U5D3 0 1.59159E-03U6D3 0 2.93602E-05U8D3 0 7.02573E-03 $ D7A step9a Doppler T450 13 MTD7A P9D3 0 6.10960E-07P0D3 0 4.78303E-08P1D3 0 4.80911E-06 13 MTD7A P2D3 0 4.83150E-07FXEB 0 1.18581E-18FI5B 0 1.95612E-18 13 MTD7A FPMB 0 2.63860E-08FSMB 0 1.32357E-07PFP1 0 1.48547E-04 13 MTD7A ODUM 0 7.10570E-06 13 MTD7B U5D3 0 1.51857E-03U6D3 0 4.29541E-05U8D3 0 7.01739E-03 $ D7B step9a Doppler T450 13 MTD7B P9D3 0 8.89152E-07P0D3 0 1.01627E-07P1D3 0 7.65925E-06 13 MTD7B P2D3 0 1.17615E-06FXEB 0 1.32691E-18FI5B 0 2.79694E-18 13 MTD7B FPMB 0 3.78067E-08FSMB 0 1.27643E-07PFP1 0 2.15243E-04 13 MTD7B ODUM 0 9.98957E-06 13 MTD7C U5D3 0 1.51739E-03U6D3 0 4.31822E-05U8D3 0 7.01669E-03 $ D7C step9a Doppler T450 13 MTD7C P9D3 0 8.92907E-07P0D3 0 1.02608E-07P1D3 0 7.70723E-06 13 MTD7C P2D3 0 1.19082E-06FXEB 0 1.32844E-18FI5B 0 2.81092E-18 13 MTD7C FPMB 0 3.79972E-08FSMB 0 1.27559E-07PFP1 0 2.16377E-04 13 MTD7C ODUM 0 1.00410E-05 13 MTD7D U5D3 0 1.58776E-03U6D3 0 3.00730E-05U8D3 0 7.02503E-03 $ D7D step9a Doppler T450 13 MTD7D P9D3 0 6.23519E-07P0D3 0 4.99826E-08P1D3 0 4.96106E-06 13 MTD7D P2D3 0 5.11627E-07FXEB 0 1.19583E-18FI5B 0 2.00014E-18 13 MTD7D FPMB 0 2.69833E-08FSMB 0 1.32197E-07PFP1 0 1.52079E-04 13 MTD7D ODUM 0 7.25174E-06 13 MTC3A U5D3 0 1.67622E-03U6D3 0 1.39548E-05U8D3 0 7.03477E-03 $ C3A step9a Doppler T450 13 MTC3A P9D3 0 2.91113E-07P0D3 0 1.11439E-08P1D3 0 2.34882E-06 13 MTC3A P2D3 0 1.07566E-07FXEB 0 1.15271E-18FI5B 0 1.75772E-18 13 MTC3A FPMB 0 2.36725E-08FSMB 0 1.36523E-07PFP1 0 7.15577E-05 13 MTC3A ODUM 0 3.11252E-06 13 MTC3B U5D3 0 1.63936E-03U6D3 0 2.06752E-05U8D3 0 7.03060E-03 $ C3B step9a Doppler T450 13 MTC3B P9D3 0 4.39235E-07P0D3 0 2.48693E-08P1D3 0 3.95960E-06 13 MTC3B P2D3 0 2.73560E-07FXEB 0 1.33630E-18FI5B 0 2.57121E-18 13 MTC3B FPMB 0 3.46725E-08FSMB 0 1.34993E-07PFP1 0 1.05181E-04 13 MTC3B ODUM 0 4.20417E-06 13 MTC3C U5D3 0 1.63873E-03U6D3 0 2.07816E-05U8D3 0 7.03060E-03 $ C3C step9a Doppler T450 13 MTC3C P9D3 0 4.41280E-07P0D3 0 2.51154E-08P1D3 0 3.98616E-06 13 MTC3C P2D3 0 2.76926E-07FXEB 0 1.33839E-18FI5B 0 2.58387E-18 13 MTC3C FPMB 0 3.48442E-08FSMB 0 1.34958E-07PFP1 0 1.05723E-04 13 MTC3C ODUM 0 4.22135E-06 13 MTC3D U5D3 0 1.67448E-03U6D3 0 1.42691E-05U8D3 0 7.03477E-03 $ C3D step9a Doppler T450 13 MTC3D P9D3 0 2.97156E-07P0D3 0 1.16273E-08P1D3 0 2.42225E-06 13 MTC3D P2D3 0 1.13498E-07FXEB 0 1.16363E-18FI5B 0 1.79534E-18 13 MTC3D FPMB 0 2.41808E-08FSMB 0 1.36586E-07PFP1 0 7.31363E-05 13 MTC3D ODUM 0 3.16530E-06 13 MTC4A U5D3 0 1.59402E-03U6D3 0 2.87337E-05U8D3 0 7.02643E-03 $ C4A step9a Doppler T450 13 MTC4A P9D3 0 5.98846E-07P0D3 0 4.62357E-08P1D3 0 4.72510E-06 13 MTC4A P2D3 0 4.59861E-07FXEB 0 1.19889E-18FI5B 0 2.02267E-18 13 MTC4A FPMB 0 2.72809E-08FSMB 0 1.31592E-07PFP1 0 1.46134E-04 13 MTC4A ODUM 0 6.97427E-06 13 MTC4B U5D3 0 1.52072E-03U6D3 0 4.22163E-05U8D3 0 7.01808E-03 $ C4B step9a Doppler T450 13 MTC4B P9D3 0 8.72323E-07P0D3 0 9.91933E-08P1D3 0 7.58762E-06 13 MTC4B P2D3 0 1.13609E-06FXEB 0 1.33943E-18FI5B 0 2.91732E-18 13 MTC4B FPMB 0 3.94305E-08FSMB 0 1.26843E-07PFP1 0 2.12816E-04 13 MTC4B ODUM 0 9.81572E-06 13 MTC4C U5D3 0 1.51961E-03U6D3 0 4.24249E-05U8D3 0 7.01808E-03 $ C4C step9a Doppler T450 13 MTC4C P9D3 0 8.75869E-07P0D3 0 1.00090E-07P1D3 0 7.63213E-06 13 MTC4C P2D3 0 1.14937E-06FXEB 0 1.34068E-18FI5B 0 2.93039E-18 13 MTC4C FPMB 0 3.96092E-08FSMB 0 1.26759E-07PFP1 0 2.13860E-04 13 MTC4C ODUM 0 9.86161E-06 13 MTC4D U5D3 0 1.59068E-03U6D3 0 2.93338E-05U8D3 0 7.02643E-03 $ C4D step9a Doppler T450 13 MTC4D P9D3 0 6.09854E-07P0D3 0 4.80542E-08P1D3 0 4.85334E-06

13 MTC4D P2D3 0 4.83220E-07FXEB 0 1.20695E-18FI5B 0 2.06001E-18 13 MTC4D FPMB 0 2.77879E-08FSMB 0 1.31474E-07PFP1 0 1.49117E-04 13 MTC4D ODUM 0 7.09666E-06 13 MTC5A U5D3 0 1.50494E-03U6D3 0 4.46530E-05U8D3 0 7.01739E-03 $ C5A step9a Doppler T450 13 MTC5A P9D3 0 8.66203E-07P0D3 0 1.06919E-07P1D3 0 7.08762E-06 13 MTC5A P2D3 0 1.12385E-06FXEB 0 1.19910E-18FI5B 0 2.20716E-18 13 MTC5A FPMB 0 2.98088E-08FSMB 0 1.24875E-07PFP1 0 2.26453E-04 13 MTC5A ODUM 0 1.17288E-05 13 MTC5B U5D3 0 1.39659E-03U6D3 0 6.47191E-05U8D3 0 7.00417E-03 $ C5B step9a Doppler T450 13 MTC5B P9D3 0 1.21293E-06P0D3 0 2.17559E-07P1D3 0 1.07385E-05 13 MTC5B P2D3 0 2.66266E-06FXEB 0 1.28776E-18FI5B 0 3.09193E-18 13 MTC5B FPMB 0 4.18776E-08FSMB 0 1.17497E-07PFP1 0 3.24576E-04 13 MTC5B ODUM 0 1.73296E-05 13 MTC5C U5D3 0 1.39492E-03U6D3 0 6.50243E-05U8D3 0 7.00417E-03 $ C5C step9a Doppler T450 13 MTC5C P9D3 0 1.21704E-06P0D3 0 2.19367E-07P1D3 0 1.07914E-05 13 MTC5C P2D3 0 2.69207E-06FXEB 0 1.28825E-18FI5B 0 3.10473E-18 13 MTC5C FPMB 0 4.20535E-08FSMB 0 1.17371E-07PFP1 0 3.26106E-04 13 MTC5C ODUM 0 1.74270E-05 13 MTC5D U5D3 0 1.50021E-03U6D3 0 4.55271E-05U8D3 0 7.01669E-03 $ C5D step9a Doppler T450 13 MTC5D P9D3 0 8.80389E-07P0D3 0 1.10744E-07P1D3 0 7.25382E-06 13 MTC5D P2D3 0 1.17656E-06FXEB 0 1.20466E-18FI5B 0 2.24277E-18 13 MTC5D FPMB 0 3.02935E-08FSMB 0 1.24652E-07PFP1 0 2.30751E-04 13 MTC5D ODUM 0 1.19492E-05 13 MTC6A U5D3 0 1.50967E-03U6D3 0 4.40675E-05U8D3 0 7.01739E-03 $ C6A step9a Doppler T450 13 MTC6A P9D3 0 8.77469E-07P0D3 0 1.04889E-07P1D3 0 6.89736E-06 13 MTC6A P2D3 0 1.08853E-06FXEB 0 1.16801E-18FI5B 0 2.04645E-18 13 MTC6A FPMB 0 2.76363E-08FSMB 0 1.25348E-07PFP1 0 2.22594E-04 13 MTC6A ODUM 0 1.15932E-05 13 MTC6B U5D3 0 1.40229E-03U6D3 0 6.40362E-05U8D3 0 7.00417E-03 $ C6B step9a Doppler T450 13 MTC6B P9D3 0 1.23171E-06P0D3 0 2.14847E-07P1D3 0 1.05299E-05 13 MTC6B P2D3 0 2.59152E-06FXEB 0 1.26871E-18FI5B 0 2.90716E-18 13 MTC6B FPMB 0 3.93700E-08FSMB 0 1.17969E-07PFP1 0 3.19944E-04 13 MTC6B ODUM 0 1.71120E-05 13 MTC6C U5D3 0 1.40056E-03U6D3 0 6.43588E-05U8D3 0 7.00417E-03 $ C6C step9a Doppler T450 13 MTC6C P9D3 0 1.23616E-06P0D3 0 2.16739E-07P1D3 0 1.05862E-05 13 MTC6C P2D3 0 2.62197E-06FXEB 0 1.26933E-18FI5B 0 2.91975E-18 13 MTC6C FPMB 0 3.95431E-08FSMB 0 1.17844E-07PFP1 0 3.21544E-04 13 MTC6C ODUM 0 1.72135E-05 13 MTC6D U5D3 0 1.50424E-03U6D3 0 4.50605E-05U8D3 0 7.01669E-03 $ C6D step9a Doppler T450 13 MTC6D P9D3 0 8.93324E-07P0D3 0 1.09152E-07P1D3 0 7.08693E-06 13 MTC6D P2D3 0 1.14791E-06FXEB 0 1.17455E-18FI5B 0 2.08414E-18 13 MTC6D FPMB 0 2.81502E-08FSMB 0 1.25070E-07PFP1 0 2.27483E-04 13 MTC6D ODUM 0 1.18421E-05 13 MTC7A U5D3 0 1.67017E-03U6D3 0 1.50869E-05U8D3 0 7.03407E-03 $ C7A step9a Doppler T450 13 MTC7A P9D3 0 3.12399E-07P0D3 0 1.29200E-08P1D3 0 2.60925E-06 13 MTC7A P2D3 0 1.29458E-07FXEB 0 1.19033E-18FI5B 0 1.89089E-18 13 MTC7A FPMB 0 2.54729E-08FSMB 0 1.36460E-07PFP1 0 7.71488E-05 13 MTC7A ODUM 0 3.29951E-06 13 MTC7B U5D3 0 1.63060E-03U6D3 0 2.23248E-05U8D3 0 7.02990E-03 $ C7B step9a Doppler T450 13 MTC7B P9D3 0 4.69103E-07P0D3 0 2.86752E-08P1D3 0 4.35070E-06 13 MTC7B P2D3 0 3.25800E-07FXEB 0 1.36794E-18FI5B 0 2.76092E-18 13 MTC7B FPMB 0 3.72441E-08FSMB 0 1.34548E-07PFP1 0 1.13241E-04 13 MTC7B ODUM 0 4.46648E-06 13 MTC7C U5D3 0 1.62990E-03U6D3 0 2.24451E-05U8D3 0 7.02990E-03 $ C7C step9a Doppler T450 13 MTC7C P9D3 0 4.71370E-07P0D3 0 2.89708E-08P1D3 0 4.38074E-06 13 MTC7C P2D3 0 3.29972E-07FXEB 0 1.37003E-18FI5B 0 2.77517E-18 13 MTC7C FPMB 0 3.74374E-08FSMB 0 1.34506E-07PFP1 0 1.13853E-04 13 MTC7C ODUM 0 4.48588E-06 13 MTC7D U5D3 0 1.66808E-03U6D3 0 1.54631E-05U8D3 0 7.03407E-03 $ C7D step9a Doppler T450 13 MTC7D P9D3 0 3.19318E-07P0D3 0 1.35306E-08P1D3 0 2.69847E-06 13 MTC7D P2D3 0 1.37344E-07FXEB 0 1.20216E-18FI5B 0 1.93588E-18 13 MTC7D FPMB 0 2.60807E-08FSMB 0 1.36481E-07PFP1 0 7.90403E-05 13 MTC7D ODUM 0 3.36175E-06 01 water in Be, G and Radiation Basket different from Ken's setup 9/98 13 FALSI ALF4 0 3.88984E-02SIF4 0 5.94365E-03 13 H2OBE BE-H 0 6.68610E-02BE-O 0 3.34305E-02 13 H2OG G-H 0 6.68610E-02G-O 0 3.34305E-02 13 H2ORB RB-H 0 6.68610E-02RB-O 0 3.34305E-02 13 H2OR HH2O 0 6.68610E-02OH2O 0 3.34305E-02 01 13 different Graphite density 9/98 01 13 GRAF GRAF 0 8.52340E-02 13 GRAF GRAF 0 8.02300E-02 13 H2OS HS4 0 6.68610E-02OS4 0 3.34305E-02 13 H2OCR CRH 0 6.68610E-02CRO 0 3.34305E-02 13 ALS ALS4 0 6.02669E-02B10S 0 2.98636E-07B11S 0 1.21115E-06 13 ALCR CRAL 0 6.02669E-02B10S 0 2.98636E-07B11S 0 1.21115E-06

13 ALB ALB 0 6.02669E-02B10B 0 2.98636E-07B11B 0 1.21115E-06 13 ALBX ALB 0 5.60774E-02SIB 0 4.06809E-03MGB 0 2.01411E-04 13 LEAD PBS 0 3.29620E-02 13 BE BET 0 1.23640E-01 13 ALP ALT 0 6.02669E-02 14 FE3A MTE3A 0.14380 CLAD 0.21570 MOD 0.64050 14 FE3A FALSI 0.14380 14 FE3B MTE3B 0.14380 CLAD 0.21570 MOD 0.64050 14 FE3B FALSI 0.14380 14 FE3C MTE3C 0.14380 CLAD 0.21570 MOD 0.64050 14 FE3C FALSI 0.14380 14 FE3D MTE3D 0.14380 CLAD 0.21570 MOD 0.64050 14 FE3D FALSI 0.14380 14 FE7A MTE7A 0.14380 CLAD 0.21570 MOD 0.64050 14 FE7A FALSI 0.14380 14 FE7B MTE7B 0.14380 CLAD 0.21570 MOD 0.64050 14 FE7B FALSI 0.14380 14 FE7C MTE7C 0.14380 CLAD 0.21570 MOD 0.64050 14 FE7C FALSI 0.14380 14 FE7D MTE7D 0.14380 CLAD 0.21570 MOD 0.64050 14 FE7D FALSI 0.14380 14 FC3A MTC3A 0.14380 CLAD 0.21570 MOD 0.64050 14 FC3A FALSI 0.14380 14 FC3B MTC3B 0.14380 CLAD 0.21570 MOD 0.64050 14 FC3B FALSI 0.14380 14 FC3C MTC3C 0.14380 CLAD 0.21570 MOD 0.64050 14 FC3C FALSI 0.14380 14 FC3D MTC3D 0.14380 CLAD 0.21570 MOD 0.64050 14 FC3D FALSI 0.14380 14 FC7A MTC7A 0.14380 CLAD 0.21570 MOD 0.64050 14 FC7A FALSI 0.14380 14 FC7B MTC7B 0.14380 CLAD 0.21570 MOD 0.64050 14 FC7B FALSI 0.14380 14 FC7C MTC7C 0.14380 CLAD 0.21570 MOD 0.64050 14 FC7C FALSI 0.14380 14 FC7D MTC7D 0.14380 CLAD 0.21570 MOD 0.64050 14 FC7D FALSI 0.14380 14 FE4A MTE4A 0.14380 CLAD 0.21570 MOD 0.64050 14 FE4A FALSI 0.14380 14 FE4B MTE4B 0.14380 CLAD 0.21570 MOD 0.64050 14 FE4B FALSI 0.14380 14 FE4C MTE4C 0.14380 CLAD 0.21570 MOD 0.64050 14 FE4C FALSI 0.14380 14 FE4D MTE4D 0.14380 CLAD 0.21570 MOD 0.64050 14 FE4D FALSI 0.14380 14 FE5A MTE5A 0.14380 CLAD 0.21570 MOD 0.64050 14 FE5A FALSI 0.14380 14 FE5B MTE5B 0.14380 CLAD 0.21570 MOD 0.64050 14 FE5B FALSI 0.14380 14 FE5C MTE5C 0.14380 CLAD 0.21570 MOD 0.64050 14 FE5C FALSI 0.14380 14 FE5D MTE5D 0.14380 CLAD 0.21570 MOD 0.64050 14 FE5D FALSI 0.14380 14 FE6A MTE6A 0.14380 CLAD 0.21570 MOD 0.64050 14 FE6A FALSI 0.14380 14 FE6B MTE6B 0.14380 CLAD 0.21570 MOD 0.64050 14 FE6B FALSI 0.14380 14 FE6C MTE6C 0.14380 CLAD 0.21570 MOD 0.64050 14 FE6C FALSI 0.14380 14 FE6D MTE6D 0.14380 CLAD 0.21570 MOD 0.64050 14 FE6D FALSI 0.14380 14 FD3A MTD3A 0.14380 CLAD 0.21570 MOD 0.64050 14 FD3A FALSI 0.14380 14 FD3B MTD3B 0.14380 CLAD 0.21570 MOD 0.64050 14 FD3B FALSI 0.14380 14 FD3C MTD3C 0.14380 CLAD 0.21570 MOD 0.64050 14 FD3C FALSI 0.14380 14 FD3D MTD3D 0.14380 CLAD 0.21570 MOD 0.64050 14 FD3D FALSI 0.14380 14 FD4A MTD4A 0.14380 CLAD 0.21570 MOD 0.64050 14 FD4A FALSI 0.14380 14 FD4B MTD4B 0.14380 CLAD 0.21570 MOD 0.64050 14 FD4B FALSI 0.14380 14 FD4C MTD4C 0.14380 CLAD 0.21570 MOD 0.64050 14 FD4C FALSI 0.14380

14 FD4D MTD4D 0.14380 CLAD 0.21570 MOD 0.64050 14 FD4D FALSI 0.14380 14 FD6A MTD6A 0.14380 CLAD 0.21570 MOD 0.64050 14 FD6A FALSI 0.14380 14 FD6B MTD6B 0.14380 CLAD 0.21570 MOD 0.64050 14 FD6B FALSI 0.14380 14 FD6C MTD6C 0.14380 CLAD 0.21570 MOD 0.64050 14 FD6C FALSI 0.14380 14 FD6D MTD6D 0.14380 CLAD 0.21570 MOD 0.64050 14 FD6D FALSI 0.14380 14 FD7A MTD7A 0.14380 CLAD 0.21570 MOD 0.64050 14 FD7A FALSI 0.14380 14 FD7B MTD7B 0.14380 CLAD 0.21570 MOD 0.64050 14 FD7B FALSI 0.14380 14 FD7C MTD7C 0.14380 CLAD 0.21570 MOD 0.64050 14 FD7C FALSI 0.14380 14 FD7D MTD7D 0.14380 CLAD 0.21570 MOD 0.64050 14 FD7D FALSI 0.14380 14 FC4A MTC4A 0.14380 CLAD 0.21570 MOD 0.64050 14 FC4A FALSI 0.14380 14 FC4B MTC4B 0.14380 CLAD 0.21570 MOD 0.64050 14 FC4B FALSI 0.14380 14 FC4C MTC4C 0.14380 CLAD 0.21570 MOD 0.64050 14 FC4C FALSI 0.14380 14 FC4D MTC4D 0.14380 CLAD 0.21570 MOD 0.64050 14 FC4D FALSI 0.14380 14 FC5A MTC5A 0.14380 CLAD 0.21570 MOD 0.64050 14 FC5A FALSI 0.14380 14 FC5B MTC5B 0.14380 CLAD 0.21570 MOD 0.64050 14 FC5B FALSI 0.14380 14 FC5C MTC5C 0.14380 CLAD 0.21570 MOD 0.64050 14 FC5C FALSI 0.14380 14 FC5D MTC5D 0.14380 CLAD 0.21570 MOD 0.64050 14 FC5D FALSI 0.14380 14 FC6A MTC6A 0.14380 CLAD 0.21570 MOD 0.64050 14 FC6A FALSI 0.14380 14 FC6B MTC6B 0.14380 CLAD 0.21570 MOD 0.64050 14 FC6B FALSI 0.14380 14 FC6C MTC6C 0.14380 CLAD 0.21570 MOD 0.64050 14 FC6C FALSI 0.14380 14 FC6D MTC6D 0.14380 CLAD 0.21570 MOD 0.64050 14 FC6D FALSI 0.14380 14 ME3A FE3A 1.00000 14 ME3B FE3B 1.00000 14 ME3C FE3C 1.00000 14 ME3D FE3D 1.00000 14 ME7A FE7A 1.00000 14 ME7B FE7B 1.00000 14 ME7C FE7C 1.00000 14 ME7D FE7D 1.00000 14 MC3A FC3A 1.00000 14 MC3B FC3B 1.00000 14 MC3C FC3C 1.00000 14 MC3D FC3D 1.00000 14 MC7A FC7A 1.00000 14 MC7B FC7B 1.00000 14 MC7C FC7C 1.00000 14 MC7D FC7D 1.00000 14 ME4A FE4A 1.00000 14 ME4B FE4B 1.00000 14 ME4C FE4C 1.00000 14 ME4D FE4D 1.00000 14 ME5A FE5A 1.00000 14 ME5B FE5B 1.00000 14 ME5C FE5C 1.00000 14 ME5D FE5D 1.00000 14 ME6A FE6A 1.00000 14 ME6B FE6B 1.00000 14 ME6C FE6C 1.00000 14 ME6D FE6D 1.00000 14 MD3A FD3A 1.00000 14 MD3B FD3B 1.00000 14 MD3C FD3C 1.00000 14 MD3D FD3D 1.00000 14 MD4A FD4A 1.00000 14 MD4B FD4B 1.00000 14 MD4C FD4C 1.00000 14 MD4D FD4D 1.00000 14 MD6A FD6A 1.00000

14 MD6B FD6B 1.00000 14 MD6C FD6C 1.00000 14 MD6D FD6D 1.00000 14 MD7A FD7A 1.00000 14 MD7B FD7B 1.00000 14 MD7C FD7C 1.00000 14 MD7D FD7D 1.00000 14 MC4A FC4A 1.00000 14 MC4B FC4B 1.00000 14 MC4C FC4C 1.00000 14 MC4D FC4D 1.00000 14 MC5A FC5A 1.00000 14 MC5B FC5B 1.00000 14 MC5C FC5C 1.00000 14 MC5D FC5D 1.00000 14 MC6A FC6A 1.00000 14 MC6B FC6B 1.00000 14 MC6C FC6C 1.00000 14 MC6D FC6D 1.00000 01 Be block, Graphite block, and Be plug composition are different 9/18 01 14 BEBLK H2OBE 0.04178 BE 0.95822 01 14 BETRP H2OBE 0.03873 BE 0.96127 01 14 REFGR H2OG 0.14165 ALB 0.07113 GRAF 0.78722 14 BEBLK H2OBE 0.04620 BE 0.95380 14 BETPI H2OBE 0.08942 BE 0.91058 14 BETPO H2OBE 0.02478 BE 0.97522 14 REFGR H2OG 0.07348 ALB 0.03922 GRAF 0.88730 01 sideplate composition is different 9/98 01 14 SIDES H2OS 0.32360 ALS 0.67640 14 SIDES H2OS 0.29235 ALS 0.70765 14 AXH2O H2ORB 0.77100 ALB 0.05315 ALBX 0.17585 14 CNTL H2OS 0.76496 ALS 0.23504 01 Reg rod out composition is different 9/98 01 14 REGO H2OS 0.68347 ALS 0.31653 14 REGO H2OCR 0.84580 ALCR 0.15420 14 REGI1 H2OCR 0.16000 ALCR 0.84000 14 REGI2 H2OCR 0.91000 ALCR 0.09000 14 ROD CRSS 0 1.81655E-02MNSS 0 1.44994E-03FESS 0 5.75879E-02 14 ROD NISS 0 7.81564E-03 01 CNTL0 use detail CR xs for water, composition same 9/98 14 CNTLO H2OCR 0.76496 ALCR 0.23504 14 CNTLI H2OS 0.53238 ALS 0.46762 14 BLADE B10C 0 7.92800E-03B11C 0 3.21530E-02C12C 0 1.00200E-02 14 BLADE ALC 0 3.81090E-02 14 POSTS H2ORB 0.50 ALB 0.50 14 BLOK1 H2ORB 0.04316 ALS 0.95684 14 BLOK2 H2ORB 0.57127 ALS 0.42873 14 BLOK3 H2ORB 0.01065 BE 0.98935 01 plug not used 14 PLUG ALP 1.0 14 GBOX H2ORB 0.37264 ALB 0.62726 14 GRID H2ORB 0.60 ALB 0.40 14 REFH2OH2OR 1.0 14 GUIDE ALCR 1.0 14 BOX ALB 1.0 14 SHIELDLEAD 1.0 14 THERM GRAF 1.0 15 SIDES S1 S2 S3 S4 S5 S6 15 REFH2OH2ORFOH2ORFIFC RB3 RB4 RB5 CIC 15 BETPO TRAP 15 BETPI HOLE 15 REGO REGOUT 15 REGI1 REGIN1 15 REGI2 REGIN2 15 ROD ROD1 01 removed RBBL2S & RBBL2E, replace with G-E9 15 BLOK1 RBBL3SRBBL4SRBBL5S 15 BLOK2 RBBL3ERBBL4ERBBL5E 15 BEBLK BEF5A BEF6A BEEC8 BE-E2 15 BEBLK BE-C2 BE-F9 15 GRID GRID 15 AXH2O AXREFTAXREFB 15 GUIDE G1 G2 G3 G4 G5 G6 15 CNTLO CNTL1OCNTL2OCNTL3OCNTL4O 15 CNTLI CNTL1ICNTL2ICNTL3ICNTL4I 15 BLADE BLADE1BLADE2BLADE3BLADE4 15 REFGR GRAF1 GRAF5 GRAF6 GRAG1 GRAG2 15 REFGR G-E9 15 GBOX GSBOX 15 SHIELDSHIELD 15 THERM TC1 TC2 15 POSTS POST3 POST4 POST1 POST2

15 BOX GBOX TCB1 TCB2 1 move E4 to D4, E5 15 ME4A E5A 15 ME4B E5B 15 ME4C E5C 15 ME4D E5D Take E5 out 15 ME5A D4A 15 ME5B D4B 15 ME5C D4C 15 ME5D D4D 2 MOVE E6 TO E5, D6 15 ME6A D6A 15 ME6B D6B 15 ME6C D6C 15 ME6D D6D 3 MOVE D3 TO E4 15 MD3A E4A 15 MD3B E4B 15 MD3C E4C 15 MD3D E4D TAKE D4 OUT 15 MD4A D4A 15 MD4B D4B 15 MD4C D4C 15 MD4D D4D TAKE D6 OUT 15 MD6A D6A 15 MD6B D6B 15 MD6C D6C 15 MD6D D6D 4 MOVE D7 TO C6 15 MD7A D7A 15 MD7B D7B 15 MD7C D7C 15 MD7D D7D 15 MD7A C6A 15 MD7B C6B 15 MD7C C6C 15 MD7D C6D 5 Move C4 to D4 15 MC4A D4A 15 MC4B D4B 15 MC4C D4C 15 MC4D D4D TAKE C5 OUT 15 MC5A C5A 15 MC5B C5B 15 MC5C C5C 15 MC5D C5D 6 MOVE C6 TO D6, C5 15 MC6A C5A 15 MC6B C5B 15 MC6C C5C 15 MC6D C5D 7 MOVE E7 TO E6 15 ME7A E6A 15 ME7B E6B 15 ME7C E6C 15 ME7D E6D 8 MOVE C3 TO C4 15 MC3A C4A 15 MC3B C4B 15 MC3C C4C 15 MC3D C4D 9 MOVE C7 TO D7 15 MC7A D7A 15 MC7B D7B 15 MC7C D7C

15 MC7D D7D 10 MOVE E3 TO D3 15 ME3A D3A 15 ME3B D3B 15 ME3C D3C 15 ME3D D3D 34 BLADE -4.11428E-01 3 2.57877E+00 4 34 BLADE 9.15215E+01 5 2.02441E+03 6 34 BLADE 4.19631E+05 7 35 ADJB 0.0.44189 0.0.44189 0.0.44189 3 35 ADJB 0.0.10218 0.0.10218 0.0.10218 4 35 ADJB 0.0.08354 0.0.08354 0.0.08354 5 35 ADJB 0.0.07663 0.0.07663 0.0.07663 6 35 ADJB 0.0.07598 0.0.07598 0.0.07598 7 36 ADJB BLADE DATASET=A.BURN 01 RINSC LEU core3+4 new fuel, 2MW 1 days rundown 02 0280000 0 0.001 1.000 1.0000 1 1 03 0 0.0 0.0 1.00 -1.000 1 0 09 U235 1U236 09 U235 2XE135 2.4200-03 PM149 1.0666-02 09 U235 2I135 6.2966-02 ETFP 1.000 09 U235 5U234 09 U236 1DUMP 09 U236 2XE135 1.5847-03 PM149 1.3691-02 09 U236 2I135 5.6307-02 ETFP 1.000 09 U236 5U235 09 U238 1PU239 09 U238 2XE135 2.8000-04 PM149 1.6100-02 09 U238 2I135 6.8349-02 ETFP 1.000 09 U238 5DUMP 09 PU239 1PU240 09 PU239 2XE135 1.1524-02 PM149 1.2390-02 09 PU239 2I135 6.4494-02 ETFP 1.000 09 PU239 5DUMP 09 PU239 8U235 09 PU240 1PU241 09 PU240 2XE135 6.9843-03 PM149 1.3690-02 09 PU240 2I135 6.7476-02 ETFP 1.000 09 PU240 8U236 09 PU241 1PU242 09 PU241 2XE135 2.3140-03 PM149 1.5240-02 09 PU241 2I135 7.0698-02 ETFP 1.000 09 PU241 8DUMP 09 PU242 1DUMP 09 PU242 2XE135 2.6448-03 PM149 1.6152-02 09 PU242 2I135 6.9001-02 ETFP 1.000 09 PU242 5PU241 09 PU242 8U238 09 XE135 6DUMP 09 XE135 1DUMP 09 I135 1DUMP 09 I135 6XE135 09 PM149 6SM149 09 SM149 1DUMP 09 ETFP 1DUMP 09 DUMP 0 10 U235 U5D3 0 10 U236 U6D3 0 10 U238 U8D3 0 10 PU239 P9D3 0 10 PU240 P0D3 0 10 PU241 P1D3 0 10 PU242 P2D3 0 10 XE135 FXEB 0 10 PM149 FPMB 0 10 I135 FI5B 0 10 SM149 FSMB 0 10 ETFP PFP1 0 10 DUMP ODUM 0 24 U235 1 235.04 24 U236 0 236.04 24 U238 0 238.05 24 PU239 1 239.05 24 PU240 0 240.05 24 PU241 1 241.06 24 PU242 0 242.06 24 XE135 0 134.90

24 I135 0 134.90 24 PM149 0 148.92 24 SM149 0 148.92 24 ETFP 0 100.00 24 DUMP 0 100.00 25 PU239 8U235 9.110-13 25 PU240 8U236 3.348-12 25 PU241 6DUMP 1.6633-9 25 PU241 8DUMP 1.665-12 25 PU242 8U238 5.842-14 25 XE135 6DUMP 2.0930-5 25 PM149 6SM149 3.6260-6 25 I135 6XE135 2.8740-5 35 NFC3A MNEW FMC3A 1 1 35 NFC3B MNEW FMC3B 1 1 35 NFC3C MNEW FMC3C 1 1 35 NFC3D MNEW FMC3D 1 1 35 NFC7A MNEW FMC7A 1 1 35 NFC7B MNEW FMC7B 1 1 35 NFC7C MNEW FMC7C 1 1 35 NFC7D MNEW FMC7D 1 1 35 NFE3A MNEW FME3A 1 1 35 NFE3B MNEW FME3B 1 1 35 NFE3C MNEW FME3C 1 1 35 NFE3D MNEW FME3D 1 1 35 NFE7A MNEW FME7A 1 1 35 NFE7B MNEW FME7B 1 1 35 NFE7C MNEW FME7C 1 1 35 NFE7D MNEW FME7D 1 1 8 MOVE C3 TO C4 35 PAC3A MC3A FMC3A 1 1 35 PAC3B MC3B FMC3B 1 1 35 PAC3C MC3C FMC3C 1 1 35 PAC3D MC3D FMC3D 1 1 35 PAC3A MC3A FMC4A 1 1 35 PAC3B MC3B FMC4B 1 1 35 PAC3C MC3C FMC4C 1 1 35 PAC3D MC3D FMC4D 1 1 10 E3 TO D3 35 PAE3A ME3A FME3A 1 1 35 PAE3B ME3B FME3B 1 1 35 PAE3C ME3C FME3C 1 1 35 PAE3D ME3D FME3D 1 1 35 PAE3A ME3A FMD3A 1 1 35 PAE3B ME3B FMD3B 1 1 35 PAE3C ME3C FMD3C 1 1 35 PAE3D ME3D FMD3D 1 1 7 E7 TO E6 35 PAE7A ME7A FME7A 1 1 35 PAE7B ME7B FME7B 1 1 35 PAE7C ME7C FME7C 1 1 35 PAE7D ME7D FME7D 1 1 35 PAE7A ME7A FME6A 1 1 35 PAE7B ME7B FME6B 1 1 35 PAE7C ME7C FME6C 1 1 35 PAE7D ME7D FME6D 1 1 1 E4 moved to D4, E5 35 PAE4A ME4A FME5A 1 1 35 PAE4B ME4B FME5B 1 1 35 PAE4C ME4C FME5C 1 1 35 PAE4D ME4D FME5D 1 1 Remove E5 35 PAE5A ME5A FMD4A 1 1 35 PAE5B ME5B FMD4B 1 1 35 PAE5C ME5C FMD4C 1 1 35 PAE5D ME5D FMD4D 1 1 2 E6 to E5, D6 35 PAE6A ME6A FMD6A 1 1 35 PAE6B ME6B FMD6B 1 1 35 PAE6C ME6C FMD6C 1 1 35 PAE6D ME6D FMD6D 1 1 3 D3 to E4 35 PAD3A MD3A FMD3A 1 1

35 PAD3B MD3B FMD3B 1 1 35 PAD3C MD3C FMD3C 1 1 35 PAD3D MD3D FMD3D 1 1 35 PAD3A MD3A FME4A 1 1 35 PAD3B MD3B FME4B 1 1 35 PAD3C MD3C FME4C 1 1 35 PAD3D MD3D FME4D 1 1 REMOVE D4 35 PAD4A MD4A FMD4A 1 1 35 PAD4B MD4B FMD4B 1 1 35 PAD4C MD4C FMD4C 1 1 35 PAD4D MD4D FMD4D 1 1 REMOVE D6 35 PAD6A MD6A FMD6A 1 1 35 PAD6B MD6B FMD6B 1 1 35 PAD6C MD6C FMD6C 1 1 35 PAD6D MD6D FMD6D 1 1 4 D7 to C6 35 PAD7A MD7A FMD7A 1 1 35 PAD7B MD7B FMD7B 1 1 35 PAD7C MD7C FMD7C 1 1 35 PAD7D MD7D FMD7D 1 1 35 PAD7A MD7A FMC6A 1 1 35 PAD7B MD7B FMC6B 1 1 35 PAD7C MD7C FMC6C 1 1 35 PAD7D MD7D FMC6D 1 1 5 C4 to D4 35 PAC4A MC4A FMD4A 1 1 35 PAC4B MC4B FMD4B 1 1 35 PAC4C MC4C FMD4C 1 1 35 PAC4D MC4D FMD4D 1 1 REMOVE C5 35 PAC5A MC5A FMC5A 1 1 35 PAC5B MC5B FMC5B 1 1 35 PAC5C MC5C FMC5C 1 1 35 PAC5D MC5D FMC5D 1 1 6 C6 TO D6, C5 35 PAC6A MC6A FMC5A 1 1 35 PAC6B MC6B FMC5B 1 1 35 PAC6C MC6C FMC5C 1 1 35 PAC6D MC6D FMC5D 1 1 9 C7 TO D7 35 PAC7A MC7A FMC7A 1 1 35 PAC7B MC7B FMC7B 1 1 35 PAC7C MC7C FMC7C 1 1 35 PAC7D MC7D FMC7D 1 1 35 PAC7A MC7A FMD7A 1 1 35 PAC7B MC7B FMD7B 1 1 35 PAC7C MC7C FMD7C 1 1 35 PAC7D MC7D FMD7D 1 1 45 FME3A E3A 45 FME3B E3B 45 FME3C E3C 45 FME3D E3D 45 FME4A E4A 45 FME4B E4B 45 FME4C E4C 45 FME4D E4D 45 FME5A E5A 45 FME5B E5B 45 FME5C E5C 45 FME5D E5D 45 FME6A E6A 45 FME6B E6B 45 FME6C E6C 45 FME6D E6D 45 FME7A E7A 45 FME7B E7B 45 FME7C E7C 45 FME7D E7D 45 FMD3A D3A 45 FMD3B D3B 45 FMD3C D3C 45 FMD3D D3D

45 FMD4A D4A 45 FMD4B D4B 45 FMD4C D4C 45 FMD4D D4D 45 FMD6A D6A 45 FMD6B D6B 45 FMD6C D6C 45 FMD6D D6D 45 FMD7A D7A 45 FMD7B D7B 45 FMD7C D7C 45 FMD7D D7D 45 FMC3A C3A 45 FMC3B C3B 45 FMC3C C3C 45 FMC3D C3D 45 FMC4A C4A 45 FMC4B C4B 45 FMC4C C4C 45 FMC4D C4D 45 FMC5A C5A 45 FMC5B C5B 45 FMC5C C5C 45 FMC5D C5D 45 FMC6A C6A 45 FMC6B C6B 45 FMC6C C6C 45 FMC6D C6D 45 FMC7A C7A 45 FMC7B C7B 45 FMC7C C7C 45 FMC7D C7D 26 U5D30 U5D30 U6D30 U8D30 P9D30 P0D30 P1D30 P2D30 FXEB0 FPMB0 FSMB0 26 U5D30 FI5B0 PFP10 39 U5D30 5 7U6D30 5 7U8D30 5 7 39 P9D30 5 7P0D30 5 7P1D30 5 7 39 P2D30 5 7FXEB0 5 7FPMB0 5 7 39 FSMB0 5 7FI5B0 5 7PFP10 1 7 40 U5D30 2 1.00000E-03 3U6D30 2 1.00000E-03 3 40 U8D30 2 1.00000E-03 3P9D30 2 1.00000E-03 3 40 P0D30 2 1.00000E-03 3P1D30 2 1.00000E-03 3 40 P2D30 2 1.00000E-03 3FXEB0 0 1.00000E-03 3 40 FPMB0 0 1.00000E-03 3FSMB0 0 1.00000E-03 3 40 FI5B0 0 1.00000E-03 3PFP10 0 1.00000E-03 3 41 U5D30 U5D30 2.52427E-04 1.0000 U5D31 2.52090E-04 1.0000 41 U5D30 U5D32 2.48755E-04 1.0000 U5D33 2.35673E-04 1.0000 41 U5D30 U5D34 2.10551E-04 1.0000 U5D35 9.30573E-05 1.0000 41 U6D30 U6D30 2.52427E-04 1.0000 U6D31 2.52090E-04 1.0000 41 U6D30 U6D32 2.48755E-04 1.0000 U6D33 2.35673E-04 1.0000 41 U6D30 U6D34 2.10551E-04 1.0000 U6D35 9.30573E-05 1.0000 41 U8D30 U8D30 2.52427E-04 1.0000 U8D31 2.52090E-04 1.0000 41 U8D30 U8D32 2.48755E-04 1.0000 U8D33 2.35673E-04 1.0000 41 U8D30 U8D34 2.10551E-04 1.0000 U8D35 9.30573E-05 1.0000 41 P9D30 P9D30 2.52427E-04 1.0000 P9D31 2.52090E-04 1.0000 41 P9D30 P9D32 2.48755E-04 1.0000 P9D33 2.35673E-04 1.0000 41 P9D30 P9D34 2.10551E-04 1.0000 P9D35 9.30573E-05 1.0000 41 P0D30 P0D30 2.52427E-04 1.0000 P0D31 2.52090E-04 1.0000 41 P0D30 P0D32 2.48755E-04 1.0000 P0D33 2.35673E-04 1.0000 41 P0D30 P0D34 2.10551E-04 1.0000 P0D35 9.30573E-05 1.0000 41 P1D30 P1D30 2.52427E-04 1.0000 P1D31 2.52090E-04 1.0000 41 P1D30 P1D32 2.48755E-04 1.0000 P1D33 2.35673E-04 1.0000 41 P1D30 P1D34 2.10551E-04 1.0000 P1D35 9.30573E-05 1.0000 41 P2D30 P2D30 2.52427E-04 1.0000 P2D31 2.52090E-04 1.0000 41 P2D30 P2D32 2.48755E-04 1.0000 P2D33 2.35673E-04 1.0000 41 P2D30 P2D34 2.10551E-04 1.0000 P2D35 9.30573E-05 1.0000 41 FXEB0 FXEB0 2.52427E-04 1.0000 FXEB1 2.52090E-04 1.0000 41 FXEB0 FXEB2 2.48755E-04 1.0000 FXEB3 2.35673E-04 1.0000 41 FXEB0 FXEB4 2.10551E-04 1.0000 FXEB5 9.30573E-05 1.0000 41 FPMB0 FPMB0 2.52427E-04 1.0000 FPMB1 2.52090E-04 1.0000 41 FPMB0 FPMB2 2.48755E-04 1.0000 FPMB3 2.35673E-04 1.0000 41 FPMB0 FPMB4 2.10551E-04 1.0000 FPMB5 9.30573E-05 1.0000 41 FSMB0 FSMB0 2.52427E-04 1.0000 FSMB1 2.52090E-04 1.0000 41 FSMB0 FSMB2 2.48755E-04 1.0000 FSMB3 2.35673E-04 1.0000 41 FSMB0 FSMB4 2.10551E-04 1.0000 FSMB5 9.30573E-05 1.0000 41 FI5B0 FI5B0 2.52427E-04 1.0000 FI5B1 2.52090E-04 1.0000 41 FI5B0 FI5B2 2.48755E-04 1.0000 FI5B3 2.35673E-04 1.0000 41 FI5B0 FI5B4 2.10551E-04 1.0000 FI5B5 9.30573E-05 1.0000 41 PFP10 PFP10 2.52427E-04 0.0000 PFP11 2.52090E-04 1.0000 41 PFP10 PFP12 2.48755E-04 1.0000 PFP13 2.35673E-04 1.0000 41 PFP10 PFP14 2.10551E-04 1.0000 PFP15 9.30573E-05 0.5000