ML13127A339

From kanterella
Jump to navigation Jump to search

Email from J. Poehler to C. Basavaraju, FW: Peer Review of SE Input for Vermont Yankee Core Plate Bolt Analysis
ML13127A339
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 02/14/2012
From: Jeffrey Poehler
NRC/NRR/DE/EVIB
To: Chakrapani Basavaraju
NRC/NRR/DE/EMCB
References
FOIA/PA-2013-0030, TAC ME0248
Download: ML13127A339 (2)


Text

Poehler, Jeffrey From:

Poehler, Jeffrey Sent:

Tuesday, February 14, 2012 1:25 PM To:

Basavaraju, Chakrapani Cc:

Kim, James; Cheruvenki, Ganesh

Subject:

FW: Peer Review of SE Input for Vermont Yankee Core Plate Bolt Analysis (ME6248)

Attachments:

Core Plate Hold Down Bolt SE Input ME6248 - (2-7-12).docx Pani, attached is my input to the SE for the areas that I reviewed - specifically, the determination of the amount of preload loss and the adequacy of the proposed inspection plan. Ganesh peer-reviewed for me, see email below.

I'm not sure how you structured your SE, so feel free to move things aro ind and cut and paste my sections as needed. We probably should meet to discuss.

I'll be in the office tomorrow and Thursday.

Thanks, Jeff From: Cheruvenki, Ganesh Sent: Tuesday, Feke1bruary 4, 02 10:20 AM To: Poehler, Jeffrey

Subject:

RE: Peer Review of SE Input for Vermont Yankee Core Plate Bolt Analysis (ME6248)

Jeff-Looks good-specially the statistical approach From: Poehler, Jeffrey Sent: Tuesday, February 14, 2012 9:25 AM To: Cheruvenki, Ganesh Cc: Purtscher, Patrick

Subject:

RE: Peer Review of SE Input for Vermont Yankee Core Plate Bolt Analysis (ME6248)

Did you guys have time to comment?

From: Cheruvenki, Ganesh Sent: Tuesday, February 07, 2012 12:07 PM To: Poehler, Jeffrey

Subject:

RE: Peer Review of SE Input for Vermont Yankee Core Plate Bolt Analysis (ME6248)

Will do.

From: Poehler, Jeffrey Sent: Tuesday, February 07, 2012 10:45 AM To: Cheruvenki, Ganesh Cc: Purtscher, Patrick

Subject:

Peer Review of SE Input for Vermont Yankee Core Plate Bolt Analysis (ME6248)

Ganesh, 21

As discussed yesterday, please peer review (technical only) my SE input for Vermont Yankee. Use TAC ME6248. Note that it is not a complete SE because Pani has the lead on the SE. He can integrate my inputs into the structure of his SE.

If you can give me comments by the end of the week that would be fine.

Pat, I copied you so if you have time to review your comments would also be appreciated.

Thanks, Jeff 22