May 21, 2013 MEMORANDUM TO:
Anthony J. Mendiola, Chief Licensing Processes Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation FROM:
Joseph A. Golla, Project Manager
/RA/
Licensing Processes Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation
SUBJECT:
CLOSED MEEING (AUDIT) OF BOILING WATER REACTOR OWNERS GROUP DATE & TIME:
Tuesday, June 25, 2013 1:00 p.m. - 4:30 p.m.
LOCATION:
U.S. Nuclear Regulatory Commission (NRC)
One White Flint North, Room O-7B4 11555 Rockville Pike Rockville, MD 20852 PURPOSE:
The purpose of this audit is for the NRC staff to review draft and other technical information pertaining to the design of the test apparatus for in-vessel downstream effects testing in support of the NRC staffs review and approval of Licensing Topical Report BWROG-TP-11-002, Boiling Water Reactor Emergency Core Cooling Suction Strainer In-Vessel Downstream effects, NEDC-33608P. (Due to the proprietary nature of the material to be reviewed and discussed, this meeting is closed to the public.)
AUDIT CONTACT:
Joseph A. Golla (301) 415-1002 Joe.Golla@nrc.gov
REFERENCE:
Licensing Topical Report BWROG-TP-11-002, Boiling Water Reactor Emergency Core Cooling Suction Strainer In-Vessel Downstream effects, NEDC-33608P (Redacted Version at Agencywide Documents Access and Management System (ADAMS) Accession No. ML110140481)
A. Mendiola PARTICIPANTS:
Participants from the NRC include members of the Office of Nuclear Reactor Regulation (NRR).
NRC Industry John Lehning Ed Asbury, GEH/BWROG Erv Geiger Stuart Cain, Alden Research Lab Steve Smith Jose Casillas, GEH/BWROG Joseph Golla, et al.
Rob Choromokos, ANATECH Dan Fouts, Entergy/BWROG Harry Goodman, Entergy/BWROG Ken Mccall, GEH/BWROG Ludwig Haber, Alden Research Lab, et al.
Project No. 691
Enclosure:
Audit Plan
ML13126A226 NRC-001 OFFICE PLPB/PM PLPB/LA SSIB/BC SNPB/BC PLPB/BC PLPB/PM NAME JGolla DBaxley SBailey SWhaley AMendiola JGolla DATE 05/15/2013 05/07/2013 05/15/2013 05/20/2013 05/21/2013 05/21/2013
ENCLOSURE AUDIT PLAN UNITED STATES NUCLEAR REGULATORY COMMISSION (NRC) AUDIT OF BOILING WATER REACTOR OWNERS GROUP (BWROG) TECHNICAL INFORMATION AND TEST PROCEDURE JUNE 25, 2013
- a.
Background:
BWROG-TP-11-002, Rev. 2 (LTR-1) was written to address the in-vessel downstream effects (DSE) issue identified in a letter written by Mr. John Grobe, Associate Director for Engineering and Safety Systems, Office of Nuclear Reactor Regulation, to Mr. Richard Anderson, BWROG Executive Chairman, dated April 10, 2008, entitled Potential Issues Related to Emergency Core Cooling Systems (ECCS)
Strainer Performance At Boiling Water Reactors (Agencywide Documents Access and Management System (ADAMS) Accession No. ML080500540). The letter encouraged the BWROG to develop a comprehensive evaluation plan integrated with the efforts of the NRC to address in-vessel DSE and six other issues detailed in the letter.
- b.
Regulatory Audit Basis: NRC regulations in 50.46 of Title 10 of the Code of Federal Regulations require that the ECCS have the capability to provide long-term cooling of the reactor core following a loss-of-cooling accident. That is, the ECCS must be able to remove decay heat, so that the core temperature is maintained at an acceptably low value for the extended period of time required by the long-lived radioactivity remaining in the core.
- c.
Regulatory Audit Methodology: The audit will be conducted in a conference room at NRC Headquarters. Members of the BWROG and BWROG consultants will provide to the NRC staff, information regarding the test apparatus constructed at Alden Research Laboratory in Holden, Massachusetts which will be used for the LTR-1 testing. The BWROG and consultants will also provide information as needed to address questions that may arise from the NRC staff regarding the test procedure and aspects of analytical portions of LTR-1.
- d.
Team Assignments: John Lehning of SNPB and Erv Geiger and Steve Smith of SSIB will conduct the audit. All three of these team members may inquire about the test apparatus and test procedure. Joseph Golla of PLPB will provide project manager support. Erv Geiger will function as team leader.
- e.
Deliverables: A regulatory audit summary will be delivered within one month of the date of the audit (by July 25, 2013). Further requests of the BWROG by the NRC staff resulting from the audit will be treated as requests for additional information and be documented separately due to the proprietary nature of the material.