0000-0157-6733-FBIR-NP, Revision 0, Fuel Bundle Information Report for Reload 12 Cycle 13
ML13123A036
Person / Time
Site: Limerick 
(NPF-085)
Issue date: 02/28/2013
From:
Global Nuclear Fuel
To:
Office of Nuclear Reactor Regulation
References
0000-0157-6733-FBIR-NP, Rev 0
Download: ML13123A036 (38)


Text

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 COLR Limerick 2 Rev. 8 Appendix A GNF Global Nuclear Fuel A Joint Venture of GEjToshibo, & Hitachi Global Nuclear Fuel 0000-0157-6733-FBIR-NP Revision 0 Class I February 2013 Non-Proprietary Information - Class I (Public)

Fuel Bundle Information Report for Limerick Unit 2 Reload 12 Cycle 13 Copyright 2013 Global Nuclear Fuel - Americas, LLC All Rights Reserved

Exelon Nuclear - Nuclear Fuels COLR Limerick 2 Rev. 8 Appendix A Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information 0000-0157-6733-FBIR-NP Reload 12 Class I (Public)

Revision 0 Important Notice Regarding Contents of This Report Please Read Carefully This report was prepared by Global Nuclear Fuel - Americas, LLC (GNF-A) solely for use by Exelon Corporation ("Recipient") in support of the operating license for Limerick Unit 2 (the "Nuclear Plant").

The information contained in this report (the "Information") is believed by GNF-A to be an accurate and true representation of the facts known by, obtained by or provided to GNF-A at the time this report was prepared.

The only undertakings of GNF-A respecting the Information are contained in the contract between Recipient and GNF-A for nuclear fuel and related services for the Nuclear Plant (the "Fuel Contract") and nothing contained in this document shall be construed as amending or modifying the Fuel Contract. The use of the Information for any purpose other than that for which it was intended under the Fuel Contract, is not authorized by GNF-A. In the event of any such unauthorized use, GNF-A neither (a) makes any representation or warranty (either expressed or implied) as to the completeness, accuracy or usefulness of the Information or that such unauthorized use may not infringe privately owned rights, nor (b) assumes any responsibility for liability or damage of any kind which may result from such use of such information.

Information Notice This is a non-proprietary version of the document 0000-0157-6733-FBIR-P, Revision 0, which has the proprietary information removed. Portions of the document that have been removed are indicated by an open and closed bracket as shown here ((

I].

Page 2

Exelon Nuclear - Nuclear Fuels COLR Limerick 2 Rev. 8 Appendix A Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information 0000-0157-6733-FBIR-NP Reload 12 Class I (Public)

Revision 0

1. Introduction and Summary This report, which supplements the Supplemental Reload Licensing Report, contains thermal-mechanical linear heat generation rate (LHGR) limits for the GNF-A fuel designs to be loaded into Limerick Unit 2 for Cycle 13. These LHGR limits are obtained from thermal-mechanical considerations only. Approved GNF-A calculation models documented in Reference 1 were used in performing this analysis.

LHGR limits as a function of exposure for each bundle of the core design are given in Appendix A. The LHGR values provided in Appendix A provide upper and lower exposure dependent LHGR boundaries which envelope the actual gadolinia dependent LHGR limits. The LHGRs reported have been rounded to two places past the decimal.

Appendix B contains a description of the fuel bundles. Table B-1 contains a summary.of bundle-specific information, and the figures provide the enrichment distribution and gadolinium distribution for the fuel bundles included in this appendix. These bundles have been approved for use under the fuel licensing acceptance criteria of Reference 1.

Page 3

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0

2. References
1. General Electric Standard Application for Reactor Fuel, NEDE-2401 1-P-A-19, May 2012; and the U.S. Supplement, NEDE-2401 I-P-A-19-US, May 2012.

Page 4

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-01 57-6733-FBIR-NP Revision 0 Appendix A U02/Gd Thermal-Mechanical LHGR Limits-Bundle Type: GNF2-P 10CG2B386-2G8.0/I 3G7.0-120T2-150-T6-3644 (GNF2)

Bundle Number: 3644 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft

((

Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit' GWd/MT (GWd/ST) kW/ft Er Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design Er))

Page 5

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0 UO2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GE 14-P 1 OCNAB3 89-14GZ-1 20T-1 50-T6-3157 (GE 14C)

Bundle Number: 3157 Peak Pellet Exposure UO2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 13.40 16.00 (14.51) 13.40 63.50 (57.61) 8.00 70.00 (63.50) 5.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit.2 GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 12.00 13.42 (12.17) 12.00 60.17 (54.59) 7.16 66.57 (60.39) 4.48 2 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design (7.0% Gd).

Page 6

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-01 57-6733-FBIR-NP Revision 0 UO2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GE 14-P 1 OCNAB3 89-15GZ-1 20T-1 50-T6-3158 (GE 14C)

Bundle Number: 3158 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 13.40 16.00 (14.51) 13.40 63.50 (57.61) 8.00 70.00 (63.50) 5.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 3 GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 12.00 13.42 (12.17) 12.00 60.17 (54.59) 7.16 66.57 (60.39) 4.48 3 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design (7.0% Gd).

Page 7

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0 U0 2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GE 14-P I OCNAB391-13GZ-1 20T-1 50-T6-3159 (GE 14C)

Bundle Number: 3159 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 13.40 16.00 (14.51) 13.40 63.50 (57.61) 8.00 70.00 (63.50) 5.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 4 GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 11.76 13.31 (12.08) 11.76 59.76 (54.21) 7.02 66.12 (59.98) 4.39 4 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design (8.0% Gd).

Page 8

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0 UO2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GE 14-P 1 OCNAB39 1-13G8.0-120T-1 50-T6-3160 (GE 14C)

Bundle Number: 3160 Peak Pellet Exposure U02 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 13.40 16.00 (14.51) 13.40 63.50 (57.61) 8.00 70.00 (63.50) 5.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit' GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 11.76 13.31 (12.08) 11.76 59.76 (54.21) 7.02 66.12 (59.98) 4.39 5 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design (8.0% Gd).

Page 9

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-01 57-6733-FBIR-NP Revision 0 U02/Gd Thermal-Mechanical LHGR Limits Bundle Type: GE14-P1OCNAB390-12GZ-120T-150-T6-3161 (GE14C)

Bundle Number: 3161 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 13.40 16.00 (14.51) 13.40 63.50 (57.61) 8.00 70.00 (63.50) 5.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 6 GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 11.76 13.31 (12.08) 11.76 59.76 (54.21) 7.02 66.12 (59.98) 4.39 6 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design (8.0% Gd).

Page 10

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0 U02/Gd Thermal-Mechanical LHGR Limits Bundle Type: GNF2-P I 0CG2B396-6G7.0/6G6.0-120T2-150-T6-3648 (GNF2)

Bundle Number: 3648 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft

[r Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 7 GWd/MT (GWd/ST) kW/ft Er 7 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design Er 1].

Page 11

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0 UO2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GNF2-P 1 0CG2B404-12G6.0-120T2-150-T6-3 643 (GNF2)

Bundle Number: 3643 Peak Pellet Exposure UO2 LHGR Limit GWd/MT (GWd/ST) kW/ft Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit' GWd/MT (GWd/ST) kW/ft

((

8 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design

[I

)).

Page 12

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0 U02/Gd Thermal-Mechanical LHGR Limits Bundle Type: GNF2-P 10CG2B389-14GZ-120T2-150-T6-3645 (GNF2)

Bundle Number: 3645 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft

((

Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 9 GWd/MT (GWd/ST) kW/ft Er 9 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design E[

1].

Page 13

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0 Reload 12 Class I (Public)

UO2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GNF2-P 10CG2B39 1-15GZ-1 20T2-150-T6-3646 (GNF2)

Bundle Number: 3646 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit '0 GWd/MT (GWd/ST) kW/ft Er 10 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design Er 1].

Page 14

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0 U0 2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GNF2-P10CG2B392-14GZ-120T2-150-T6-3647 (GNF2)

Bundle Number: 3647 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft Er Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit GWd/MT (GWd/ST) kW/ft Er((_________________

Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design Er))

Page 15

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0 UO2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GNF2-P 10CG2B391-14GZ-1 20T2-150-T6-3725 (GNF2)

Bundle Number: 3725 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit' 2 GWd/MT (GWd/ST) kW/ft Er 12 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design Er 1].

Page 16

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0 U0 2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GNF2-P 10CG2B388-2G8.0/8G7.0/2G6.0-120T2-150-T6-4218 (GNF2)

Bundle Number: 4218 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit'3 GWd/MT (GWd/ST) kW/ft I((

13 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design 1[

1].

Page 17

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0 U0 2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GNF2-P 1OCG2B386-14GZ-120T2-150-T6-4221 (GNF2)

Bundle Number: 4221 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 14 GWd/MT (GWd/ST) kW/ft

((l 14 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design

((

1].

Page 18

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-01 57-6733-FBIR-NP Revision 0 UO2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GNF2-P IOCG2B388-14GZ-120T2-150-T6-4220 (GNF2)

Bundle Number: 4220 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft I((

Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit' 5 GWd/MT (GWd/ST) kW/ft 15 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design

((

R))

Page 19

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0 U02/Gd Thermal-Mechanical LHGR Limits Bundle Type: GNF2-P 10CG2B396-2G7.0/10G6.0-120T2-150-T6-4217 (GNF2)

Bundle Number: 4217 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 16 GWd/MT (GWd/ST) kW/ft 16 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design

((

].R Page 20

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public')

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0 Reload 12 Class I (Public)

Appendix B Fuel Bundle Information Table B-I Bundle Specific Information Max Exposure Fuel Bundle Enrichment Weight Weight k at at Max k, Bundle Number (wt% U-235)

U 20 0C GWd/MT (kg)

(kg) 17 (GWd/ST)

GNF2-P1OCG2B3386-2G8.0/13G7.0-120T2-150-T6-3644 3644 (GNF2)

GE 14-P 1OCNAB389-14GZ-120T-150-T6-3157 (GEl4C)

GE14-P1OCNAB389-15GZ-120T-150-T6-3158 (GE14C)

GE14-PIOCNAB391-13GZ-120T-150-T6-3159 (GE14C)

GE14-P1OCNAB391-13G8.0-3160 120T-150-T6-3160 (GE 14C)

GE 14-P I OCNAB390-12GZ-120T-150-T6-3161 (GE14C)

GNF2-P10CG2B396-6G7.0/6G6.0-120T2-150-T6-3648 3648 (GNF2)

GNF2-P 10CG2B404-12G6.0-3643 120T2-150-T6-3643 (GNF2)

GNF2-P10CG2B389-14GZ-120T2-150-T6-3645 (GNF2)

GNF2-P10CG2B391-15GZ-120T2-150-T6-3646 (GNF2)

GNF2-P10CG2B392-14GZ-120T2-150-T6-3647 (GNF2)

GNF2-P10CG2B391-14GZ-120T2-150-T6-3725 (GNF2) 7 Maximum lattice k. for the most reactive uncontrolled state plus a ((

)) adder for uncertainties.

Page 21

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-01 57-6733-FBIR-NP Revision 0 GNF2-P10CG2B388-2G8.0/8G7.0/2G6.0-120T2-150-4218 T6-4218 (GNF2)

GNF2-P10CG2B386-14GZ-120T2-150-T6-4221 (GNF2)

GNF2-P 10CG2B388-14GZ-120T2-150-T6-4220 (GNF2)

GNF2-P10CG2B396-2G7.0/1 0G6.0-120T2-150-T6-4217

]

4217 (GNF2)

Page 22

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0 Figure B-I Enrichment and Gadolinium Distribution for EDB No. 3644 Fuel Bundle GNF2-PIOCG2B386-2G8.0/13G7.0-120T2-150-T6-3644 (GNF2)

Page 23

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-01 57-6733-FBIR-NP Revision 0

((

Figure B-2 Enrichment and Gadolinium Distribution for EDB No. 3157 Fuel Bundle GE14-PIOCNAB389-14GZ-120T-150-T6-3157 (GE14C)

Page 24

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0

[1 Figure B-3 Enrichment and Gadolinium Distribution for EDB No. 3158 Fuel Bundle GE14-PIOCNAB389-15GZ-120T-150-T6-3158 (GE14C)

Page 25

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0 Figure B-4 Enrichment and Gadolinium Distribution for EDB No. 3159 Fuel Bundle GEI4-P1OCNAB391-13GZ-120T-150-T6-3159 (GE14C)

Page 26

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0 Figure B-5 Enrichment and Gadolinium Distribution for EDB No. 3160 Fuel Bundle GEI4-PIOCNAB391-13G8.0-120T-150-T6-3160 (GEI4C)

Page 27

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0

((

1]

Figure B-6 Enrichment and Gadolinium Distribution for EDB No. 3161 Fuel Bundle GE14-P1OCNAB390-12GZ-120T-150-T6-3161 (GE14C)

Page 28

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0 1]

Figure B-7 Enrichment and Gadolinium Distribution for EDB No. 3648 Fuel Bundle GNF2-P10CG2B396-6G7.0/6G6.0-120T2-150-T6-3648 (GNF2)

Page 29

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0 157-6733-FBIR-NP Revision 0

[1 Figure B-8 Enrichment and Gadolinium Distribution for EDB No. 3643 Fuel Bundle GNF2-PIOCG2B404-12G6.0-120T2-150-T6-3643 (GNF2)

Page 30

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-01 57-6733-FBIR-NP Revision 0 Figure B-9 Enrichment and Gadolinium Distribution for EDB No. 3645 Fuel Bundle GNF2-PIOCG2B389-14GZ-120T2-150-T6-3645 (GNF2)

Page 31

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0

((

Figure B-10 Enrichment and Gadolinium Distribution for EDB No. 3646 Fuel Bundle GNF2-PIOCG2B391-15GZ-120T2-150-T6-3646 (GNF2)

Page 32

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0 Figure B-II Enrichment and Gadolinium Distribution for EDB No. 3647 Fuel Bundle GNF2-PIOCG2B392-14GZ-120T2-150-T6-3647 (GNF2)

Page 33

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0

))

Figure B-12 Enrichment and Gadolinium Distribution for EDB No. 3725 Fuel Bundle GNF2-PIOCG2B391-14GZ-120T2-150-T6-3725 (GNF2)

Page 34

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0

((

Figure B-13 Enrichment and Gadolinium Distribution for EDB No. 4218 Fuel Bundle GNF2-PIOCG2B388-2G8.0/8G7.0/2G6.0-120T2-150-T6-4218 (GNF2)

Page 35

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0 Figure B-14 Enrichment and Gadolinium Distribution for EDB No. 4221 Fuel Bundle GNF2-PIOCG2B386-14GZ-120T2-150-T6-4221 (GNF2)

Page 36

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-01 57-6733-FBIR-NP Revision 0

((

Figure B-15 Enrichment and Gadolinium Distribution for EDB No. 4220 Fuel Bundle GNF2-P10CG2B388-14GZ-120T2-150-T6-4220 (GNF2)

Page 37

Exelon Nuclear - Nuclear Fuels Core Operating Limtis Report Non-Proprietary Information Submitted in Accordance with 10 CFR 2.390 Limerick Unit 2 Non-Proprietary Information Reload 12 Class I (Public)

COLR Limerick 2 Rev. 8 Appendix A 0000-0157-6733-FBIR-NP Revision 0

((

Figure B-16 Enrichment and Gadolinium Distribution for EDB No. 4217 Fuel Bundle GNF2-P10CG2B396-2G7.0/10G6.0-120T2-150-T6-4217 (GNF2)

Page 38