ML13114A131

From kanterella
Jump to navigation Jump to search
Submittal of Discharge Monitoring Report for March 2013
ML13114A131
Person / Time
Site: Sequoyah  
Issue date: 04/12/2013
From: Simmons P
Tennessee Valley Authority
To: Morgan C
Office of Nuclear Reactor Regulation, State of TN, Dept of Environment & Conservation, Div of Water Pollution Control
References
TN0026450
Download: ML13114A131 (8)


Text

I I Tennessee Valley Authority, Post Office Box 2000, Soddy Daisy, Tennessee 37384-2000 April 12, 2013 Ms. Christina Morgan Tennessee Department of Environment and Conservation Division of Water Pollution Control Enforcement & Compliance Section 6 th Floor, L & C Annex 401 Church Street Nashville, Tennessee 37243

Dear Ms. Morgan:

TENNESSEE VALLEY AUTHORITY (TVA) - SEQUOYAH NUCLEAR PLANT (SQN) - NPDES PERMIT NO. TN0026450 - DISCHARGE MONITORING REPORT (DMR) FOR MARCH 2013 Enclosed is the March 2013 Discharge Monitoring Report for Sequoyah Nuclear Plant. There were no exceedances during the monitoring period. If you have any questions or need additional information, please contact Brad Love by email at bmlove@tva.gov or by phone at (423) 843-6714.

I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.

Sincerely, Paul R. Simmons Sequoyah Plant Manager Signatory Authority for:

John T. Carlin Site Vice President Sequoyah Nuclear Plant Enclosures cc (Enclosures):

Chattanooga Environmental Field Office U.S. Nuclear Regulatory Commission Division of Water Pollution Control Attn: Document Control Desk State Office Building, Suite 550 Washington, DC 20555 540 McCallie Avenue Chattanooga, Tennessee 37402-2013

PERMIrT'EE NAME/ADDRESS (Include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000 (INTEROFFICE OPS-5N-SQN.)

SODDY - DAISY, TN 37384 Facility "A

- SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR DISCHARGE MONITORING REPORT (DMR)

(SUBR 01)

TN0026450 1

101 G t F-FINAL PERMIT NUMBER DISCHARGE NUMBER DIFFUSER DISCHARGE MONITORING PERIQD EFFLUENT Form Approved.

OMB No. 2040-0004 I EA M

AY I ER Q

A From 1 13 1 03 01 To 1 13 1

0 1

ATTN: Brad Love NO DISCHARGE

[

NOTE: Read instructions before comlletinq this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS TEMPERATURE, WATER DEG.

SAMPLE 26.0 04 0

31/ 31 RCORDR CENTIGRADE MEASUREMENT 00010 1

0 PERMIT Req. Mon.

DEG. C.

CONTI CALCTD EFFLUENT GROSS REQUIREMENT DAILY MAX NUOUS TEMPERATURE, WATER DEG.

SAMPLE 12.2 04 0

31 / 31 MODELD CENTIGRADE MEASUREMENT 00010 Z

0 PERMIT 30.5 DEG. C.

CONTI CALCTD INSTREAM MONITORING REQUIREMENT DALYMX DEG..

NUOUS TEMP. DIFF. BETWEEN SAMP. &

SAMPLE 3

04 0

31 / 31 CALCTD UPSTRM DEG.C MEASUREMENT 00016 1

1 PERMIT 5

DEG. C.

CONTI CALCTD EFFLUENT GROSS REQUIREMENT DAILY MX NUOUS FLOW, IN CONDUIT OR THRU SAMPLE 1697 030 31/31 RCORDR TREATMENT PLANT MEASUREMENT 50050 1

0 PERMIT Req. Mon.

MGD CONTI RCORDR REQUIREMENT EFFLUENT GROSS DAILY MAX NUOUS CHLORINE, TOTAL RESIDUAL SAMPLE 0.020 0.040 19 0

12/31 GRAB MEASUREMENT 50060 1

0 PERMIT 0.1 0.1 MGIL FIVE PER CALCTD EFFLUENT GROSS REQUIREMENT MO AVG DAILY MAX WEEK TEMPERATURE - C, RATE OF SAMPLE 062 31/31 CALCTD CHANGE MEASUREMENT 82234 1

0 PERMIT 2

DEG CONTI CALCTD EFFLUENT GROSS REQUIREMENT DAILY MX ClHR NUOUS SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel Paul R. Simmons property gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the Sequoy Plant Manager information, the information submitted is, to the best of my knowledge and belief, true, accurate, _______

PlantManager

_ 423 843-6502 13 04 12 Sequoyah Plant Manager and complete. I am aware that there are significant penalties for submitting false information.

SIGNATURE OF PRINCIPAL EXECUTIVE including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY TYPED OR PRINTED CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

No closed mode operation. Veliger monitoring data is included as an attachment. The following injections occurred: 1. Floguard MS6236 (max. calc. conc. was 0.064mg/L--limit 0.2mg/L) 2.

Biodetergent 73551 (max. calc. conc. was 0.039mg/L--limit 2.Omg/L)

EPA Form 3320-1 (REV 3/99)

Previous editions may be used Page 1 of 1

Mean# of NOTES: %

Sample Date Mean # of

% Setler Water Sample Date Asiatic Water LOCATION Gravid Asiatic COLLECTED BY ZMIm3 Temp. ('C)

Clamslm3 Temp. ('C)

Clam 01/04/2013 01/09/2013 01/15/2013 01/22/2013 01/29/2013 02/05/2013 02/12/2013 02/19/2013 02/26/2013 03/08/2013 03/13/2013 03/18/2013 0

0 0

0 0

29 0

0 0

0 0

0 0

0 0

0 0

100 0

0 0

0 0

0 8

29.7 30.2 24.9 8.1 30.4 28.9 27 8

28 9.02 28 01/04/2013 01/09/2013 01/15/2013 01/22/2013 01/29/2013 02/05/2013 02/12/2013 02/19/2013 02/26/2013 03/08/2013 03/13/2013 03/18/2013 0

0 0

0 0

0 0

0 0

0 0

0 8

29.7 30.2 24.9 8.1 30.4 28.9 27 8

28 9.02 28 1-ISV-24-1234 1-25-545 1-25-545 1-25-545 1-ISV-24-1234 1-25-545 1-25-545 1-25-545 1-ISV-24-1234 1-25-545 I-ISV-24-1234 1-25-545 WAW CR PPG BB BB PPG PPG PPG JAG PPG ACL PPG

PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000 (INTEROFFICE OPS-5N-SQN)

SODDY - DAISY, TN 37384 Facility TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR For DISCHARGE MONITORING REPORT (DMR)

(SUBR 01)

OM TN0026450 I[

101 T_ý F-FINAL PERMIT NUMBER J

DISCHARGE NUMBER BIOMONITORING FOR OUTFALL 101 MONITORING ERIOD EFFLUENT m Approved.

B No. 2040-0004 I YEAS1.MO AYY oL.A-From [

~

j y

Tol1 103111 ATTN: Brad Love NO DISCHARGE

=

NOTE: Read instructions before completina this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS IC25 STATRE 7DAY CHR SAMPLE Monitoring 23 CERIODAPHNIA MEASUREMENT Not Required 23 TRP3B 1

0 PERMIT 43.2 PERCENT SEMI COMPOS EFFLUENT GROSS REQUIREMENT.

MINIMUM ANNUAL IC25 STATRE 7DAY CHR SAMPLE Monitoring PIMEPHALES MEASUREMENT Not Required 23 TRP6C 1

0 PERMIT 43.2 PERCENT SEMI COMPOS REQUIREMENT EFFLUENT GROSS MIMINUM

_ANNUAL SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualifed personnel Paul R. Simmons

properly gather and evaluate the information submitted. Based on my inquiry of the person or
persons who manage the system, or those persons directly responsible for gathering the Plant Manager 423 843-6502 13 04 12 information, the information submitted is, to the best of my knowledge and belief, true, accurate, 423 843-6502 13 04 12 Sequoyah Plant Manager and complete. I am aware that there are significant penalties for submitting false information, SIGNATURE OF PRINCIPAL EXECUTIVE including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY TYPED OR PRINTED CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

Toxicity was not sampled in March 2013 EPA Form 3320-1 (REV 3/99)

Previous editions may be used Page 1 of 1

PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000 (INTEROFFICE OPS-5N-SQN)

SODDY - DAISY, TN 37384 Facilitv TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

DISCHARGE MONITORING REPORT (DMR)

E TN026450 1

103 G 1

PERMIT NUMBER DISCHARGE NUMBER MONITORING PEIOD YEAR M

DA From 131031011 To 13 103 131 MAJOR Form Approved.

(SUBR 01)

OMB No. 2040-0(

F - FINAL LOW VOL. WASTE TREATMENT POND EFFLUENT NO DISCHARGE NOTE: Read instructions before completinq this form.

004 ATTN: Brad Love PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS PH SAMPLE 7

8 12 0

15/31 GRAB MEASUREMENT 00400 1

0 PERMIT 6

9 SU THREE/

GRAB EFFLUENT GROSS REQUIREMENT MINIMUM MAXIMUM WEEK SOLIDS, TOTAL SUSPENDED SAMPLE 10 13 19 0

2 / 31 GRAB MEASUREMENT 00530 1

0 PERMIT 30 100 MGIL TWICE/

GRAB EFFLUENT GROSS REQUIREMENT MO AVG DAILY MX MONTH OIL AND GREASE SAMPLE

<6

<6 19 0

2 / 31 GRAB MEASUREMENT 00556 1

0 PERMIT 15 20 MGIL TWICE/

GRAB EFFLUENT GROSS REQUIREMENT MO AVG DAILY MX

_MONTH FLOW, IN CONDUIT OR THRU SAMPLE 1.096 1.157 3**

0 31/31 RCORDR TREATMENT PLANT MEASUREMENT 50050 1

0 PERMIT Req. Mon.

Req. Mon MGD SEE RCORDR EFFLUENT GROSS REQUIREMENT MO AVG DAILY MX PERMIT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my PHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel Paul R. Simmons properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, M

423 843-6502 13 04 12 Sequoyah Plant Manager and complete. I am aware that there are significant penalties for submitting false information, SIGNATURE OF PRINCIPAL EXECUTIVE TYPED OR PRINTED including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY CO E TYD ORPRINATE I

(Referencealattachmentsher CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

EPA F:)rm 3320-1 (REV 3199)

Previous editions may be used Paae I of I

PERMIITTEE NAME/ADDRESS (Include Facilitv Name/Location if Different)

Name TVA

  • SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000 (INTEROFFICE OPS-5N-SQN)

SODDY - DAISY, TN 37384 Facility TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY ATTN: Brad Love NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR DISCHARGE MONITORING REPORT (DMR)

(SUBR 01)

PRTNUMBER 110 ER FR-CFINAL LEMIUMBER J

DISCHARGE NUMBER RECYCLED COOLING WATER Form Approved.

OMB No. 2040-0004 h'nKI I T r'1DKj`

I*I D IZOI:nI Ittrl I

EFFLUENT IYEARJ MO IDAY I Y

NO DISCHARGEMFDA From L 13 03 01 To 13 03 I31

  • 1*

aLI NO I E-: Read instructions before compleinq this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS TEMPERATURE, WATER DEG.

SAMPLE CENTIGRADE MEASUREMENT 04 00010 1

0 PERMIT REPORT DEG C CONTIN CALCTD EFFLUENT GROSS VALUE REQUIREMENT DAILY MX UOUS TEMPERATURE, WATER DEG.

SAMPLE CENTIGRADE MEASUREMENT 04 00010 Z

0 PERMIT 30.5' DEG C CONTIN CALCTD INSTREAM MONITORING REQUIREMENT DAILY MX UOUS TEMP. DIFF. BETWEEN SAMP. &

SAMPLE

      • 04 UPSTRM DEG.C MEASUREMENT 00016 1

0 PERMIT 5

DEG C CONTIN CALCTD EFFLUENT GROSS VALUE REQUIREMENT DAILY MX UOUS FLOW, IN CONDUIT OR THRU SAMPLE 03 TREATMENT PLANT MEASUREMENT 50050 1

0 PERMIT Req. Mon.

MGD CONTIN RCORDR EFFLUENT GROSS VALUE REQUIREMENT DAILY MX UOUS CHLORINE, TOTAL RESIDUAL SAMPLE MEASUREMENT 50060 1

0 PERMIT 0.1 0.1 MGIL Five per CALCTD EFFLUENT GROSS VALUE REQUIREMENT MO AVG DAILY MX Week TEMPERATURE - C, RATE OF SAMPLE 4*

CHANGE MEASUREMENT 04 82234 1

0 PERMIT 2

DEG C CONTIN CALCTD EFFLUENT GROSS VALUE REQUIREMENT DAILY MX UOUS SAMPLE MEASUREMENT PERMIT REQUIREMENT NAMEITITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel Paul R. Simmons properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the Seruoyah Plant Manager information, the information submitted is, to the best of my knowledge and belief, true, accurate, 423 843-6502 13 04 12 Sequoyah Plant Manager and complete. I am aware that there are significant penalties for submitting false information.

SIGNATURE OF PRINCIPAL EXECUTIVE including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY TYPED OR PRINTED CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

No Discharge this Period EPA Form 3320-1 (REV 3199)

Previous editions may be used Page 1 of 1

PERMI-TFEE NAME/ADDRESS (Include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000 (INTEROFFICE OPS-5N-SQN)

SODDY - DAISY, TN 37384 Facility TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR DISCHARGE MONITORING REPORT (DMR)

(SUBR 01)

TNOL2645PO I 110 T F -FINAL PERMIT NUMBER DISCHARGE NUMBER RECYCLED COOLING WATER

=

MONITORING ERIOD I EFFLUENT Form Approved.

OMB No. 2040-0004 I YEAR I MO I DAY I I YEAR I MO I

DAYJ From 1 131031011 To r 131 03 311 ATTN: Brad Love NO DISCHARGE W

NOTE: Read instructions before completinq this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS IC25 STATRE 7DAY CHR SAMPLE 3**

2 CERIODAPHNIA MEASUREMENT TRP3B 1

0 0

PERMIT 43.2 PERCENT SEMI COMPOS REQUIREMENT EFFLUENT GROSS VALUE MINIMUM ANNUAL IC25 STATRE 7DAY CHR SAMPLE 23 PIMEPHALES MEASUREMENT 23 TRP6C 1

0 0

PERMIT 43.2 PERCENT SEMI COMPOS EFFLUENT GROSS VALUE REQUIREMENTMINIMUM ANNUAL SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel Paul R. Simmons properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true. accurate, Sequoyah Plant Manager and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.

TYPED OR PRINTED COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference alt attachments here)

No Discharge this Period EPA Form 3320-1 (REV 3199)

Previous editions may be used Page 1 of 1

PERMII-FEE NAME/ADDRESS (Include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000 (INTEROFFICE OPS-5N-SQN)

SODDY - DAISY, TN 37384 Facility TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY ATTN: Brad Love NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR DISCHARGE MONITORING REPORT (DMR)

(SUBR 01)

S TN0026450 I

118 G F - FINAL PERMIT NUM3ER DISCHARGE NUMBER WASTEWATER & STORM WATER MONITORING PERI EFFLUENT From YEAR I MO D Y**

NO DISCHARGE j

Form Approved.

OMB No. 2040-0004 OuTi E: Reao instructions betore comoletina this torm.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS OXYGEN, DISSOLVED (DO)

SAMPLE MEASUREMENT 19 00300 1

0 PERMIT 2

1 MGIL TWICE/

GRAB EFFLUENT GROSS REQUIREMENT MINIMUM WEEK SOLIDS, TOTAL SUSPENDED SAMPLE MEASUREMENT 19 00530 1

0 PERMIT 100 MGIL TWICE/

GRAB EFFLUENT GROSS REQUIREMENT DAILY MX WEEK SOLIDS, SETTLEABLE SAMPLE MEASUREMENT 25 00545 1

0 PERMIT MUL ONCE/

GRAB EFFLUENT GROSS REQUIREMENT DAILY X

MONTH FLOW, IN CONDUIT OR THRU SAMPLE TREATMENT PLANT MEASUREMENT 03 50050 1

0 PERMIT Req. Mon.

Req, Mon.

MGD ONCE/

ESTIMA REQUIREMENT EFFLUENT GROSS R

MO AVG DAILY MX BATCH SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel e

Paul R. Simmons properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the S

u Plant Manager information, the information submitted is, to the best of my knowledge and belief, true, accurate, __423 843-6502 13 04 12 Sequoyah Plant Manager and complete. I am aware that there are significant penalties for submitting false information, SIGNATURE OF PRINCIPAL EXECUTIVE including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY TYPED OR PRINTED CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

During this reporting period, there has been no flow from the Dredge Pond other than that resulting from rainfall.

EPA Form 3320-1 (REV 3199)

Previous editions may be used Page 1 of 1